64
The Radiology Information Solution CRIS 06.12t Specific Release Notes v1.2 Copyright © Healthcare Software Systems 2004 Registered Office: Healthcare Software Systems, 3rd Floor i2 Mansfield, Hamilton Court, Oakham Business Park, Mansfield. NG18 5BR General Information This release replaces all previous major, minor and emergency releases. All changes included in a major release will also be included in a minor release. There is no downtime needed to install a release unless specifically mentioned in the Trust Implementation Issues section. All sites can be upgraded to this release of CRIS. No changes are included in a release until the change passes all tests and that change has no known issues or has caused any new known issues at the time of release. Each release of CRIS is not normally released with any known major issues unless specifically mentioned in the know issues section. Last Updated: HSS 05/05/2022 Healthcare Software Systems – Commercial in Confidence Page 1 of 64
Transcript
Page 1: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

CRIS 06.12t Specific Release Notes v1.2Copyright© Healthcare Software Systems 2004 Registered Office: Healthcare Software Systems, 3rd Floor i2 Mansfield, Hamilton Court, Oakham Business Park, Mansfield. NG18 5BR

General InformationThis release replaces all previous major, minor and emergency releases. All changes included in a major release will also be included in a minor release. There is no downtime needed to install a release unless specifically mentioned in the Trust Implementation Issues section. All sites can be upgraded to this release of CRIS. No changes are included in a release until the change passes all tests and that change has no known issues or has caused any new known issues at the time of release. Each release of CRIS is not normally released with any known major issues unless specifically mentioned in the know issues section.

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 1 of 47

Page 2: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

1. ContentsCRIS 06.12t Specific Release Notes v1.2....................................................................................1

Copyright...............................................................................................................................1General Information...............................................................................................................1

1. Contents...................................................................................................................................22. Issue Summaries......................................................................................................................4

2.1 New Features......................................................................................................................42.2 Enhancements....................................................................................................................42.3 Issues Resolved..................................................................................................................5

2.3.1 Dictation........................................................................................................................52.3.2 Reporting......................................................................................................................5

2.4 House Keeping....................................................................................................................53. Trust Implementation Issues.....................................................................................................6

3.1 Standard issues:..............................................................................................................63.2 Optional, for issues by request only:................................................................................6

4. Change Details.........................................................................................................................74.1 Dictation..............................................................................................................................74.2 Reporting.............................................................................................................................7

5. Known Issues........................................................................................................................... 85.1 Known Issue Summaries....................................................................................................8

5.1.1 Database......................................................................................................................85.1.2 Diary.............................................................................................................................85.1.3 Dictation........................................................................................................................85.1.4 Event Details................................................................................................................95.1.5 Film Tracking..............................................................................................................105.1.6 Interfaces....................................................................................................................105.1.7 Login...........................................................................................................................105.1.8 Menu Options.............................................................................................................105.1.9 Nuclear Medicine........................................................................................................115.1.10 Other.........................................................................................................................115.1.11 Patient...................................................................................................................... 115.1.12 Post Processing........................................................................................................125.1.13 Printing..................................................................................................................... 125.1.14 Reporting..................................................................................................................125.1.15 Scanning...................................................................................................................135.1.16 Setup Tables............................................................................................................135.1.17 Statistics...................................................................................................................145.1.18 Stats Scheduler........................................................................................................155.1.19 Voice Recognition.....................................................................................................155.1.20 Worklists...................................................................................................................16

5.2 Known Issue Details..........................................................................................................175.2.1 Database....................................................................................................................175.2.2 Diary...........................................................................................................................175.2.3 Dictation......................................................................................................................185.2.4 Event Details..............................................................................................................205.2.5 Film Tracking..............................................................................................................255.2.6 Interfaces....................................................................................................................255.2.7 Login...........................................................................................................................265.2.8 Menu Options.............................................................................................................275.2.9 Nuclear Medicine........................................................................................................27

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 2 of 47

Page 3: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

5.2.10 Other.........................................................................................................................275.2.11 Patient...................................................................................................................... 295.2.12 Post Processing........................................................................................................315.2.13 Printing..................................................................................................................... 325.2.14 Reporting..................................................................................................................335.2.15 Scanning...................................................................................................................375.2.16 Setup Tables............................................................................................................385.2.17 Statistics...................................................................................................................425.2.18 Stats Scheduler........................................................................................................455.2.19 Voice Recognition.....................................................................................................465.2.20 Worklists...................................................................................................................47

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 3 of 47

Page 4: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

2. Issue Summaries

The following section summarises the changes made in this version of CRIS relative to release 1.06.12t. Changes are divided into new features and issues resolved. Details of each change are provided later in the document in "Change Details". Navigation is best achieved by searching the document for the relevant "HSS Ref" number.

Notes on the following tables:HSS Ref. - this relates to internal HSS change numbers.LSP Ref. - this relates to LSP Incident, Problem or RFC reference numbers.By Request - these changes can only be activated by HSS on a specific request by a Trust.Trust Interest - these changes are deemed to be of significance to trusts either because they impact end users, require trust action or are desirable new features/fixes, which trusts are most likely to take advantage of.

2.1 New Features

2.2 Enhancements

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 4 of 47

Page 5: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

2.3 Issues Resolved

2.3.1 Dictation

HSS Ref LSP Ref Description By Request Trust

Interest219213 - Resetting dictation addendum status. - Yes

2.3.2 Reporting

HSS Ref LSP Ref Description By Request Trust

Interest

207902 -Opening a report page from the events list with a reporting page open leaves the dictation on 20STRT

- -

2.4 House KeepingHouse keeping is reserved for general code tidying which may provide minor improvements in efficiency or cosmetic changes that do not relate to issues resolved nor add new functionality.

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 5 of 47

Page 6: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

3. Trust Implementation IssuesThis section details issues which must be addressed by the Trust before a release or, where they are for issues which are only by request, before a particular feature is activated.

3.1 Standard issues:

3.2 Optional, for issues by request only:

None.

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 6 of 47

Page 7: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

4. Change DetailsThis section provides further details of each change.

HEAD refers to the development and unreleased testing versions of CRIS. Changes reported in HEAD are either new features not in any previous version of CRIS or issues that have only been introduced or discovered during development or testing of the next release of CRIS. Issues reported in a particular release, HEAD or otherwise, may also be pertinent to other releases of CRIS.

4.1 Dictation

219213 - Resetting dictation addendum status.Reported in: 06.12 Fixed in: 06.12t Resolved by: sjennings (Steven Jennings)

Description: It is possible to accidentally reset a dictation status from addendum to untyped. This can be done by loading a dictation in the reporting page and then moving back to the event details and re-loading the reporting page without clearing the patient.Resolution: The dictation status of addendum now persists when clearing the report screen, regardless of mode or way in which the report editor was accessed. This includes accessing the report page of many events from the same patient event list.

4.2 Reporting

207902 - Opening a report page from the events list with a reporting page open leaves the dictation on 20STRTReported in: 06.12 Fixed in: 2.07.12a, 06.12t Resolved by: bcarroll (Ben Carroll)

Description: Opening a report page from the events list with a reporting page open leaves the dictation with status 20STRT.Resolution: Status now reset correctly.

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 7 of 47

Page 8: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

5. Known IssuesThis section provides a list of outstanding issues in this version of CRIS.

5.1 Known Issue Summaries

5.1.1 Database

HSS Ref LSP Ref Description By

RequestTrust Interest

206897 - examsummary returns summary report verified when not all summary reports are verified - -

206217 FJ - 270894 Incorrect Foreign Key on the Injected By Field - -

207627 - Extend column phrases.code to varchar2(12) - -

5.1.2 Diary

HSS Ref LSP Ref Description By

RequestTrust Interest

205820 HD186764 - CSC Ref Can expand appointments into unavailable slots - Yes

202609 - Errors thrown in the Java console when navigating - -

205976 FJ 270911 Able to book appointment into end-dated room. - Yes204234 - Waiting status popup size in diary - -204608 - Room slots not unallocated when deleting exam - -

207858 - Diary still doing slow queries when changing date with no room or exam selected - -

203846 - Selecting a patient in the diary puts it on the changed scratch pad - -

200278 - Simultaneous Diary searching forward. - -

5.1.3 Dictation

HSS Ref LSP Ref Description By

RequestTrust Interest

208565 - Warning message when dictating a report for an already reported exam - -

212376 - Still able to Dictate From Day List - -

201725 - insert/overwrite display gone from the dictation page - -

214961 - dictation playback controls use wrong symbol - -

200553 - On system without sound, attempting to play dictation consumes available processor resources - -

207050 - default action to pop up messages - -209173 - Dictation starts unintentionally - -202811 HD125581 Dictation Icon Disappearing when Exam Deleted - -

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 8 of 47

Page 9: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

209378 - Comment fields on dictation page are small on widescreen monitors - -

202653 - Exams wrongly marked as being dictated - -

5.1.4 Event Details

HSS Ref LSP Ref Description By

RequestTrust Interest

214133 - End time of cancellation status not populated - -

213846 - Able to delete exams without DELETE_EXAMS permission - -

213700 0213627 Event History for Previous Patient - -200377 - Event hover help text not disappearing - -215324 - Event date wrong on Status Change - -

200555 - On-Call times are not applied at time of attendance - -

214657 - Error messages when converting orders to requests etc refer to 'could not save attendance'. - -

207162 - Event saved without exam or referrer - -203024 - Uppercase referral source searching - -

216620 - Pressing unaction on an event in unprocessed list does not display correct icon. - -

202885 050I0221340 Blank Event Status/History - -202628 FJ 215220 Lead Clinician Details not refreshing - -

206059 FJ-268520 Lists closing down when changing a patient's status on the waiting list - -

210939 - Long event comment and clinical history scrolled to bottom - -

209166 - Validation of dates in yyyy/mm/dd format - -

205805 - Blanked request date can cause CRIS to show dummy date of 01/01/2099 - -

209393 - User is not warned of exam detail changes when clearing without saving. - -

205659 - Room field in event details allows any room to be entered - -

205674 - Undo an attendance with two attended statuses - -

218039 - Integrity constraint error when attempting to move an event - -

217591 - Cancel reason is not always validated - -

210274 - Events on Waiting list cannot have a Future end-dated referrer - -

208989 HSS 0208869 Mandatory LMP Information - -

201869 - DNA status being inserted in backlog mode - -201128 - Cannot unverify auto reported obstetric exam - -207587 - Problems with 'tabbing' in event details screen - -

206477 - Searching for referral location will display end dated codes - -

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 9 of 47

Page 10: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

202088 - Booked Date not being updated on event - -

5.1.5 Film Tracking

HSS Ref LSP Ref Description By Request Trust

Interest201554 - Still able to move films with permission turned off - Yes216486 5617121 Pulling list sort order - -

5.1.6 Interfaces

HSS Ref LSP Ref Description By Request Trust

Interest

204078 - Todays Messages creates an unnecessary database connection which is never used - -

203968 - Resource leak when using the web based messages manager functionality. - -

213321 - CRIS not closing PACS images - -216972 - Unclosed connection in patient manager - -

207962 - Waiting List entry doesn't get sent for an initial book mode of "O" - -

5.1.7 Login

HSS Ref LSP Ref Description By

RequestTrust Interest

205010 - Clarify error messages produced during login - -

208876 - Login Error Message "Could Not Load Radiologists" - -

208128 HSS 0207866

Unable to log in with a role containing a whitespace. - Yes

202683 - Login errors not displaying any useful information - -

5.1.8 Menu Options

HSS Ref LSP Ref Description By Request Trust

Interest

205148 - User ID is not available in the View Log table output. - -

5.1.9 Nuclear Medicine

HSS Ref LSP Ref Description By Request Trust

Interest201235 - Exceeding ARSAC limit with multiple NM injections - -202062 - Create Multiple Phials - -

5.1.10 Other

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 10 of 47

Page 11: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

HSS Ref LSP Ref Description By

RequestTrust Interest

211116 - SFTP client will not work with Java 1.4 - -207505 - Re ordering tables by primitive types - -

214670 - Image zooming for request cards using the mouse drag is initially slow. - -

208233 HSS 208192

Porter requests are not cancelled when the appointment is cancelled. - -

200595 - Surname Validation - -200630 - Alt Left and Right tabs movement stops - -200705 - Counting a batch sometimes throws Oracle error - -214770 - Not possible to revert changes to Options/Theme - -

5.1.11 Patient

HSS Ref LSP Ref Description By Request Trust

Interest

207740 -No error message is displayed when creating a patient directly from an order and there is a duplicate hospital number

- -

216393 - Unchecked Warning alarms - -203739 - Deleted patients show in name search - -211131 - Viewlog Missing entries - -

211157 - HIS Details not displaying demographic history correctly - -

202701 - Null pointer error on unlinking patient - -214516 - Incorrect terminology when matching a patient - -200778 - Move hospital numbers between merged patients - -218623 - Circular Link in Merge Chain - -212389 - Patient DOB validation - -206640 - Incorrect Patients loaded using Accession Number - -200616 - Flagging possible duplicates in patient search - Yes

212979 - Blank HospNo field on patient search for PAS patients with a hospital number - -

5.1.12 Post Processing

HSS Ref LSP Ref Description By Request Trust

Interest

206719 FJ 280542 Unable to Post Process from Report Info list (unallocated) - Yes

200672 - Numeric entry in mAs field - -

200528 - Projection details without a projection type are allowed to be saved - -

208289 HSS 208207 Post Processing symbol left on event - -

202151 - Post processing start time - -

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 11 of 47

Page 12: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

5.1.13 Printing

HSS Ref LSP Ref Description By

RequestTrust Interest

205529 - Ability to change font and font size - -

205554 - Page Preview in Print Content Editor does not inform user of parse errors - -

204691 - Flexiforms with lookup table entry fields do not print prefix/suffix - -

203556 050I0224295 Hospital cancel and reappointment letter does not mention change Yes -

202862 - Ending a report line with ~ causes following text to not print - -

210544 - Labels marked as in comments on flexible forms print twice. - -

201204 - Requests print appointment labels - -

201751 - Auto Capitalisation doesn't work well for postcodes or Scottish names - -

5.1.14 Reporting

HSS Ref LSP Ref Description By

RequestTrust Interest

208499 - Possible to verify a report as another user - -

208638 - Unchecked and addended reports do not display in unverified list on report info screen. - Yes

207465 - Reports saved with blank "reported_by" - Yes

208009 - Coded phrases assigned to users not always being available - Yes

208010 - Tick box hover help on fetal anomaly report pages - -

213492 - Batch verify incorrectly populates reporting session - -

212653 - Inaccuracy in Printing and viewing Obs Graphs - -212659 - Date last verified - -217151 - Verified status of different sections of a report - -216259 - Right click verify does not disable report editor - -203309 226764 Useless Series Report Message sent to PACS - -

210388 - Some obstetric reports loading an invalid lookup table - -

202800 - Null verification details - -210916 - Verified reports with blank verified by. - -210203 - Merge eFilm PACS DTI Clear - -

204817 - Exhausted resultset saving NW anomaly obs report - -

204541 - Unverifying during batch verify session for obstetric exams - -

209543 - Obstetric report changed values not saved warning - -

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 12 of 47

Page 13: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

209551 - EDD not shared on new multiple-fetus obstetric reports - -

209835 - Fife obstetric anomaly report layout problem at low resolutions - -

209855 - Post Exam Auto Report reported by - -204213 - Reports with no reporting radiologist. - Yes

202508 CSC - HD118394 Duplicates on Report Info List - -

202766 - Voice recognition insert phrase - -201214 - Filtering Diagnosis Code Help. - -212043 - Auto report with end dated Clinician code - -

212050 -Batch Auto Report/Track screen is inadvertently closed when loading an event from the Report Info List

- -

5.1.15 Scanning

HSS Ref LSP Ref Description By Request Trust

Interest

203155 - Rescanning images other than REQCARD type uses REQCARD settings - -

203162 - Deleting or rescanning request cards causing save problems. - -

212996 - can't delete or rescan corrupt scanned images - -

5.1.16 Setup Tables

HSS Ref LSP Ref Description By

RequestTrust Interest

200725 - Closed Setup Tables reopen - -

212388 - Copying Appointment Diary Weeks on wrong days - -

200542 CSC - G150075009 Cannot End Date Radiologist in Staff Tables - -

202943 - Possible to create multiple blank radiologists - -210875 - Validate Days of Week in Exams Per Hospital - -

202406 - Signed fields in setup tables which should be unsigned - -

202030 - StatsDatafld not saving but no error message - -201942 - New user group trust not validated. - -201506 - Deleting Entries in Exams Per Hosp Setup - -

201178 - Flexiforms cache is not refreshed when Refresh Tables is selected - -

200872 - Changing a security setting can update more than one value. - -

200866 - The same warning displayed four times on the Log In ID field - -

203290 - Blank grey areas in MOD_JAVA message of the - -

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 13 of 47

Page 14: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

day218863 - Translation table not saving changes - -208076 - View Only Groups - -

205029 - Cannot add new exam code without filling in DWT field - -

208713 - Coded Phrase trust code problems - -206102 - Can't delete values from Normal table - -209165 - Scottish Bank Holidays - -

206751 280560 ExamCodesPerHospital Letter field lists letters for current site not selected site - -

209314 - CRIS MOBL - Able to add Code of more than 1 character - -

204042 - Multi Line Phrase Setup - -

209018 FJ 050I0306662 Department hover help in the Rooms Setup - Yes

5.1.17 Statistics

HSS Ref LSP Ref Description By Request Trust

Interest

207715 - Foreign fields in output fields of stats don't perform null checks. - -

209084 - Removing multiple selection criteria in stats. - -209111 - Popup table displayed on valid selection criteria. - -

209146 - Linking tables being inserted when auto joins are not to be used. - -

214857 - Stat selection of foreign field >= blank value gives error - -

206418 - Invalid query error on single foreign field selection in stats - -

206194 - Saving output format in stats leaves blank output on stat - Yes

206806 - Selecting end dated codes in stats - Yes206384 - <> operator on nullable fields in stats - Yes206368 - Stats version, date and update date - -201550 - Stopping stats on log out / shutdown - -

202815 - Stats "in" Operator on selection Criteria of derived fields - -

202820 HSS REF 202818

Changing "look and feel" theme to "windows" breaks display of stats - -

210621 - ~ is not handled the same in stats as in reporting. - -212292 - Stats report viewer doesn't handle ~( - -202878 - Selecting from prompt table problem - -

204321 - To use "Stop Stat" button stat, has to be reselected from previous stats screen - -

204371 - View and Print stat button disabling - -204943 - Case sensitivity on type "L" datafields - -203391 - No output format error message breaks run stat - -

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 14 of 47

Page 15: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

button

5.1.18 Stats Scheduler

HSS Ref LSP Ref Description By Request Trust

Interest

201188 - No message to the user if the report file cannot be FTP'd to the remote server - -

212061 - Stopping long stats with large sql query - -

203392 - Date expansion in the scheduler start date and end date fields - -

5.1.19 Voice Recognition

HSS Ref LSP Ref Description By Request Trust

Interest206299 - Assigned Dragon VR User Changing. - -

201872 - Voice recognition disabled icon after clear patient command. - -

204486 - Abnormal application termination with Voice Recognition enabled - -

208435 - Correction menu fails to close after corrections - -218587 - Wrong profiles loaded/saved - -205785 - Assigning Dragon user to new CRIS user - -205783 - Dragon User displayed on microphone icon - -

5.1.20 Worklists

HSS Ref LSP Ref Description By

RequestTrust Interest

207233 - Dictation untyped incorrect figures - -

200586 - Hover help does not work correctly on the Porters List - -

201868

CSC HD91590 This issue has been resolved in CRIS 06.12f

New patient matching on order selection - -

202228 - Dictation list order - -205231 - Batch verify list report button - -200761 - Report info list date expansion - -

209383 - Report info list fetches all results before refreshing list - -

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 15 of 47

Page 16: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

5.2 Known Issue Details

5.2.1 Database

206897 - examsummary returns summary report verified when not all summary reports are verifiedReported in: 06.12   Fixed in: 07.12

Description: After changing the report status of a verified obstetric report using the report properties option the reports are still shown as verified on the patients event list.

206217 - Incorrect Foreign Key on the Injected By FieldReported in: 06.12   Fixed in: 07.12

Description: Currently the database has a foreign key CRIS_EXAMS_FK#3, which validates the EXAMS.INJECTED_BY field against the HDSUSE.USER_ID, however the software only allows the values stored in the RADIOL.CODE field to be used as the value. This foreign key needs to change to validate the EXAMS.INJECTED_BY field against the RADIOL.CODE field.Incident No. FJ - 270894

207627 - Extend column phrases.code to varchar2(12)Reported in: 06.12   Fixed in: 07.12a

Description: One site requires the reporting phrase code enlarging to allow at least 10 character codes

5.2.2 Diary

205820 - Can expand appointments into unavailable slotsReported in: 06.12   Fixed in: 2.07.12a

Description: It is possible to drag an appointment into the diary and then expand the appointment into closed slots. This is even possible with the setting APPT_OVERBOOK and APPT_OVERRIDE set to 'N'Incident No. HD186764 - CSC Ref

202609 - Errors thrown in the Java console when navigatingReported in: 06.12   Fixed in: 07.12

Description: An 'Array Index Out Of Bounds' and a 'Null Pointer Exception' are thrown in the Java Console when right clicking on the grey area of an ignored exam. This does not affect the user visible behaviour of CRIS.

205976 - Able to book appointment into end-dated room.Reported in: 06.04   Fixed in: 2.07.12a

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 16 of 47

Page 17: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

Description: It is possible to book an appointment into a room which has been end-dated.Incident No. FJ 270911

204234 - Waiting status popup size in diaryReported in: 06.12   Fixed in: 07.12

Description: The changing of an event status to waiting within the diary, by using the right click on an appointment in a slot, brings up a screen, which has fields that are unusable as they are squashed and not displayed correctly when there are more than 4 waiting status codes

204608 - Room slots not unallocated when deleting examReported in: 06.12   Fixed in: 2.07.12a

Description: It is possible for the diary slots used to be calculated incorrectly when deleting an appointment for an event with multiple exams at the same time as changing the appointment to special or marking one or more of the exams as ignored.

207858 - Diary still doing slow queries when changing date with no room or exam selectedReported in: 06.12   Fixed in: 2.07.12a

Description: Change 207707 prevents the diary doing a large query when created without using Add to Diary. However the large query is still performed when changing date before an exam is selected, when changing range view, when refreshing, etc.

203846 - Selecting a patient in the diary puts it on the changed scratch padReported in: 06.12   Fixed in: 2.07.12a

Description: The changed Appointments scratch pad should list all appointments that have been changed in the diary since the scratch pad was cleared. It is also wrongly showing all appointments that have been selected but not changed on the diary.

200278 - Simultaneous Diary searching forward.Reported in: 06.04   Fixed in: 2.07.12a

Description: If users on separate screens select auto search forward on different PC's at same time for same type of exam then too many of the diary slots can be set as allocated.

5.2.3 Dictation

208565 - Warning message when dictating a report for an already reported examReported in: 06.12   Fixed in: 2.07.12a

Description: The locking facilities in CRIS prevent two people from creating a report at the same time. However, they do not prevent a non VR user from creating a dictation when the

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 17 of 47

Page 18: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

event has already had a textual report saved without using the CRIS dictation module, for example using voice recognition.

212376 - Still able to Dictate From Day ListReported in: 06.12   Fixed in: 2.07.12d

Description: If you have access to the daylist, and you put CRIS in Dictation Mode, you can still dictate any event. This is regardless of whether you have permission to Dictate or not.

You cannot dictate from the events list but still from the daylist, and if you click save on an event, the next option is to Save & Dictate

201725 - insert/overwrite display gone from the dictation pageReported in: 06.04   Fixed in: 07.12

Description: The label which displays whether the user is in insert or overwrite mode on the dictation page has disappeared.

214961 - dictation playback controls use wrong symbolReported in: 06.12

Description: The dictation playback controls on the report editor or the report viewer uses the wrong symbol. When you press play the play arrow is replaced by a black circle to represent the fact that this button now functions as a stop button. The symbol for a stop button is a square. A (red) circle is used to mark a record button.

200553 - On system without sound, attempting to play dictation consumes available processor resourcesReported in: 06.04   Fixed in: 07.12

Description: On a system where sound is not available (e.g. no sound drivers), clicking on the dictation buttons on the report screen causes CRIS to consume 99% CPU time.

207050 - default action to pop up messagesReported in: 06.12   Fixed in: 2.07.12a

Description: Review the pop up messages which appear when dictating to ensure that the safe option or NO option is the default.

For example; Report in progress: yes is highlighted should be No Record Locked: OK is highlighted should be cancel

209173 - Dictation starts unintentionallyReported in: 06.12   Fixed in: 2.07.12a

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 18 of 47

Page 19: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

Description: If the event details are changed via the dictation page then typing R in the exam code, status, room or time fields toggles dictation on and off.

202811 - Dictation Icon Disappearing when Exam DeletedReported in: 06.04   Fixed in: 07.12

Description: If you have an event with multiple exams and dictate the event. Then remove the top exam for any reason (this can be in the dictation screen or event details screen also during dictating or after the dictation has been completed) the speaker icon disappears from the event on the Events Screen. You can still listen to the dictation in the dictation module and the event still appears on the dictation list, but there is still no iconIncident No. HD125581

209378 - Comment fields on dictation page are small on widescreen monitorsReported in: 06.12   Fixed in: 2.07.12a

Description: The height of the clinical history and notes fields on the dictation page are restricted to a much smaller height than would fit when displayed on a wide screen monitor.

202653 - Exams wrongly marked as being dictatedReported in: 06.12   Fixed in: 07.12

Description: If the user has two copies of CRIS running and tries to open an exam for dictating in both copies, the second exam selected correctly gives the warning saying you cant dictate two exams at the same time but still marks it as being locked and being dictated even though the user has not been allowed into the dictation page.

5.2.4 Event Details

214133 - End time of cancellation status not populatedReported in: 06.12   Fixed in: 2.09.10a

Description: When an appointment is cancelled, the end time of the cancellation status is supposed to be filled in with the time of the original appointment for the exam, if there is one present. Currently this does happen when going through the cancel finish page, but when right clicking and cancelling from an event list, this is not the case, the end time remains as null.

There is also an additional inconsistency whereby if a request is cancelled via the cancel finish page the end date and end time of the cancellation status are both null, but if a right click cancel on the request list is used the end time is null, but the end date is set to 01/01/2099.

These situations should all result in consistent data in the database.

213846 - Able to delete exams without DELETE_EXAMS permissionReported in: 06.12   Fixed in: 2.09.10a

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 19 of 47

Page 20: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

Description: It is still possible to delete exams from an event despite having the security setting DELETE_EXAMS set to NO.

213700 - Event History for Previous PatientReported in: 06.12   Fixed in: 2.07.12d

Description: It is possible to see the Event History for the previous patient when loading a patient from batch verify and a different patient is already loaded.Incident No. 0213627

200377 - Event hover help text not disappearingReported in: 06.12   Fixed in: 07.12

Description: Hover help in the event list does not disappear if the user presses F5 but doesn't move the mouse pointer first.

215324 - Event date wrong on Status ChangeReported in: 06.12   Fixed in: 2.09.10a

Description: After changing the status of an event from attended back to request, CRIS updates the request date to the date of attendance.

200555 - On-Call times are not applied at time of attendanceReported in: 06.04   Fixed in: 07.12

Description: The event on call field is set according to when the event is created and not when the patient attends.

214657 - Error messages when converting orders to requests etc refer to 'could not save attendance'.Reported in: 06.12

Description: If an error occurs while trying to save a request the error displayed can refer to problems saving the attendance.

The error message may confuse and compound the issue as it states 'could not save attendance' when the end user is actually trying to Add a request!

207162 - Event saved without exam or referrerReported in: 06.12   Fixed in: 2.07.12a

Description: An event can be saved without an exam code or referrer.

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 20 of 47

Page 21: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

203024 - Uppercase referral source searchingReported in: 06.12   Fixed in: 07.12

Description: If a referral source has been added in the setup tables with lower case name and address at the current SHA then when searching for it in the referral source prompt it cannot be found, as it does a case sensitive search. If it is outside the current SHA then the database is queried each time and the query does do a case insensitive search, and the source is returned correctly

216620 - Pressing unaction on an event in unprocessed list does not display correct icon.Reported in: 06.12   Fixed in: 2.09.10a

Description: When using the unprocessed list it is possible to action an event that has a syringe icon against it as it has been injected. This puts a processing locked icon in place of the syringe icon. It is then possible to press "Unaction" on the event, and this should remove the lock, and replace it with the previous icon, however it currently removes the lock and also the syringe icon. This could be a risk as someone may not realise that the event has already been administered with radioactive material.

202885 - Blank Event Status/HistoryReported in: 06.04   Fixed in: 07.12

Description: It is possible for an events status history to be blank.Incident No. 050I0221340

202628 - Lead Clinician Details not refreshingReported in: 06.04   Fixed in: 07.12

Description: If when switching between events on a list the user does not use F5 to clear the patient then the LEAD CLINICIAN name displayed does not clear if the second event has no lead clinician. This does not affect the data just what is displayed on the screen.Incident No. FJ 215220

206059 - Lists closing down when changing a patient's status on the waiting listReported in: 06.12   Fixed in: 2.07.12a

Description: When you have the day, waiting, appointment, and request lists open in CRIS and make a change to a patient's status on the waiting list it closes down the appointment and request list.Incident No. FJ-268520

210939 - Long event comment and clinical history scrolled to bottomReported in: 06.12   Fixed in: 2.09.10a

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 21 of 47

Page 22: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

Description: If the event comment or clinical history are longer than will fit in the text box then when the event details page is displayed they are scrolled to the end of the text rather than the beginning as you would expect.

209166 - Validation of dates in yyyy/mm/dd formatReported in: 06.12   Fixed in: 2.07.12a

Description: If you enter a date in the format yyyy/mm/dd CRIS tries to parse it as if it were in the format dd/mm/yyyy. When entering dates in this format it is possible for CRIS to convert them to unusual dates without warning.

205805 - Blanked request date can cause CRIS to show dummy date of 01/01/2099Reported in: 06.12   Fixed in: 2.07.12a

Description: If a user creates a request and blanks out the request date then this can cause CRIS to show a dummy date of 1/1/2099 when it tries to show the appropriate date for the event which for a request should be the request date.

209393 - User is not warned of exam detail changes when clearing without saving.Reported in: 06.12   Fixed in: 2.07.12a

Description: Normally when some details of an event are changed, or it is reported, dictated etc, the user is warned that there are unsaved changes when they try and clear the screen without saving. However the warning message does not appear if the details that have changed are details that are stored on the exam, rather than the event.

205659 - Room field in event details allows any room to be enteredReported in: 06.12   Fixed in: 2.07.12a

Description: The prompt list for room field on the event details page only contains rooms for the event site. However any room can be entered manually. The room prompt field should restrict the entry of room codes to those in the prompt list.

205674 - Undo an attendance with two attended statusesReported in: 06.04   Fixed in: 07.12

Description: For an event that has two attended statuses as the last two statuses in its history, when undoing the attendance, it is reset to a the status before the last attend status which is still an attended status and not to the status before both of the attendance statuses, therefore not actually undoing the attendance. It should be returned to the status that existed before it was attended.

218039 - Integrity constraint error when attempting to move an eventReported in: 06.12   Fixed in: HEAD

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 22 of 47

Page 23: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

Description: If an attendance is attempted to be moved from one patient to another, and the event is in a volume with other events, an integrity constraint error is thrown as the volume key for the event is attempted to be set to 0, which is not a valid volume key

217591 - Cancel reason is not always validatedReported in: 06.12   Fixed in: HEAD

Description: The HL7 spec states that the cancel reason should not exceed 200 characters. Rejecting a request will check the length of the text being inserted in to the ORDERS.CANCEL_REASON field. However, cancelling a request does not check the length of this text.

210274 - Events on Waiting list cannot have a Future end-dated referrerReported in: 06.12   Fixed in: 2.07.12a

Description: Events on the waiting list cannot be changed or edited if the referrer is end-dated in the future. You get an error "The Referrer was not active on the Event Date"

208989 - Mandatory LMP InformationReported in: 06.12   Fixed in: 2.07.12a

Description: CRIS does not prompt for the LMP information to be entered when an LMP sensitive exam is used within an event and the override security setting is disabled.Incident No. HSS 0208869

201869 - DNA status being inserted in backlog modeReported in: 06.12   Fixed in: 07.12

Description: When attending an appointment in backlog mode, a DNA status is inserted between the appointment status and the attended status.

201128 - Cannot unverify auto reported obstetric examReported in: 06.04   Fixed in: 07.12

Description: When an obstetric exam that is configured to be reported using a CRIS obstetrics form is reported using batch reporting then CRIS creates a report that cannot be viewed, unverified or deleted.

207587 - Problems with 'tabbing' in event details screenReported in: 06.12   Fixed in: 2.07.12a

Description: When creating a new event, if the mouse is moved over to the right hand side of the screen (e.g. to change patient type/category) you cannot tab through the fields - you cannot tab out of the 'copy to' field.

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 23 of 47

Page 24: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

206477 - Searching for referral location will display end dated codesReported in: 06.12   Fixed in: 2.07.12a

Description: If you select f4 to search for referral locations, then click in the filter box without entering any data, end dated codes are then displayed. If you then select the end dated code the expected error message is displayed

202088 - Booked Date not being updated on eventReported in: 06.12   Fixed in: 07.12

Description: When an appointment is made, the booked date of the event, viewed on the hover help of the Date column in the events list, should show the date the appointment was booked.

It currently contains the creation date which is available in another field.

5.2.5 Film Tracking

201554 - Still able to move films with permission turned offReported in: 06.04   Fixed in: 07.12

Description: When a user does not have the security settings that allows films to be moved/tracked to different locations they are still able to move them if they select an event that is not an attendance and then click the MOVE FILMS button.

216486 - Pulling list sort orderReported in: 06.12   Fixed in: 2.09.10a

Description: The list of patients in the pulling list can be sorted by any of the column headers. However when this is done the patient selected and loaded is the one that would have been in that position in the list before the list was re-ordered.Problem No. 5617121

5.2.6 Interfaces

204078 - Todays Messages creates an unnecessary database connection which is never usedReported in: 06.12   Fixed in: 07.12

Description: The Todays Messages processor creates a database connection the first time it is called in order to determine the database type. This connection is kept open but never used.

Instead it should use the connection that is being created to process the inttodo table.

203968 - Resource leak when using the web based messages manager functionality.Reported in: 06.04   Fixed in: 07.12

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 24 of 47

Page 25: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

Description: The web based messages manager functionality does not close it's connection to the JMS server when displaying a list of messages. This causes the three connection handler threads to be retained, after a significant number of operations the application server will run out of threads.

A temporary workaround is to restart the application server from time to time.

213321 - CRIS not closing PACS imagesReported in: 06.12

Description: In some instances CRIS does not close the images in PACS. When the user is reporting, when they click verify or finish, the PACS viewer does not receive a DTI message. This is not a problem when working through a worklist, as the viewer opens the next patient's images. But when they get to the end, or verify an individual patient's report, the images are left on the screen.

216972 - Unclosed connection in patient managerReported in: 06.12

Description: Interfaces can fail to save patient because the hospital number is assigned to an existing CRIS patient. This results in an unclosed connection.

207962 - Waiting List entry doesn't get sent for an initial book mode of "O"Reported in: 06.12   Fixed in: 2.07.12a

Description: A Waiting List entry doesn't get sent to PACS for an event that initially had a book mode of "O". This means that any event saved as a request before being put on the waiting list does not get sent to PACS.

5.2.7 Login

205010 - Clarify error messages produced during loginReported in: 06.12   Fixed in: 07.12

Description: Error messages produced during login contain oracle error codes that can be confusing for the user.

These error messages should be changed to be more user friendly.

208876 - Login Error Message "Could Not Load Radiologists"Reported in: 06.12   Fixed in: 2.07.12a

Description: Occasionally when users log in they get an error message "Could not load radiologists" "null"

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 25 of 47

Page 26: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

When this happens they cannot use CRIS properly and have to shut down CRIS. This is due to the previous user having a problem when they logged out that caused them to fail to save their user preferences.

208128 - Unable to log in with a role containing a whitespace.Reported in: 06.12   Fixed in: 2.07.12a

Description: If you create a new user group but enter a space in the middle of the group code, the group will not work when assigned to a users profile.Incident No. HSS 0207866

202683 - Login errors not displaying any useful informationReported in: 06.12   Fixed in: 07.12

Description: When a login fails due to the connection details being incorrect (ip / hostname / SID) or a connection cannot be made to the specified url, a null pointer is displayed on screen. A meaningful message related to the failure reason should be displayed

5.2.8 Menu Options

205148 - User ID is not available in the View Log table output.Reported in: 06.12   Fixed in: 07.12

Description: The User ID should be displayed instead of the CRIS number in the csv output from the View Log. The User ID Column was on the View Log page for all versions of CRIS before 06.12 and was lost during the re-working of View Log for 06.12 and needs to be re-instated.

5.2.9 Nuclear Medicine

201235 - Exceeding ARSAC limit with multiple NM injectionsReported in: 06.12   Fixed in: 2.07.12a

Description: It is possible to add many nuclear medicine injections to an exam that have a total Mbq that is greater than the arsac limit of the exam without a warning being displayed.

202062 - Create Multiple PhialsReported in: 06.12   Fixed in: 07.12

Description: If you create multiple identical Phials it doesn't create them with the current volume filled in with the initial volume value from the phial being copied.

5.2.10 Other

211116 - SFTP client will not work with Java 1.4

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 26 of 47

Page 27: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

Reported in: 06.12   Fixed in: 07.12

Description: The SFTP client gives errors as it uses functionality introduced into Java in version 1.5. This is not too much of an issue for clients, as most are on Java 1.5, however a lot of the database servers are on Java 1.4, which will cause a problem for the scheduler SFTP.

207505 - Re ordering tables by primitive typesReported in: 06.04   Fixed in: 2.07.12a

Description: Some lists that have numerical columns are sorted alphabetically rather than numerically when the column header is pressed.

214670 - Image zooming for request cards using the mouse drag is initially slow.Reported in: 06.12   Fixed in: 2.07.12c

Description: When an image is viewed in CRIS and is zoomed using the mouse drag left or right, it is initially quite a slow and jerky zoom rate. After the image has been rotated the zoom is much faster.

208233 - Porter requests are not cancelled when the appointment is cancelled.Reported in: 06.04   Fixed in: 2.07.12a

Description: if an appointment with a porter request is cancelled it does not cancel the porters request.Incident No. HSS 208192

200595 - Surname ValidationReported in: 06.12   Fixed in: 07.12

Description: When entering a surname longer than allowed or containing numbers the error message is not very user friendly.

200630 - Alt Left and Right tabs movement stopsReported in: 06.04   Fixed in: 07.12

Description: The facility in CRIS to use the Alt plus Left and Right keys to move between the tabs stops working once an obstetric report tab has been displayed until the patient is cleared.

200705 - Counting a batch sometimes throws Oracle errorReported in: 06.12   Fixed in: 07.12

Description: This error occurs when there is no such batch in the database.

214770 - Not possible to revert changes to Options/ThemeLast Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 27 of 47

Page 28: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

Reported in: 06.12   Fixed in: HEAD

Description: The default option select in Theme is Metal, but clicking on it changes the theme distinctly. It is not possible to revert to the default theme without restarting CRIS.

Additionally, changes to the theme are not stored as a user preference. It is unlikely users will change the theme manually every time they start or use CRIS. Thus it is probably a useless feature.

5.2.11 Patient

207740 - No error message is displayed when creating a patient directly from an order and there is a duplicate hospital numberReported in: 06.12   Fixed in: 2.07.12a

Description: When a patient is created directly from an order but doing this would create a duplicate hospital number in the hospnos table, no error is displayed but the operation fails.

216393 - Unchecked Warning alarmsReported in: 06.12   Fixed in: 2.09.10a

Description: If a patient is marked as unchecked any relevant warning alarms cannot be seen.

203739 - Deleted patients show in name searchReported in: 06.12   Fixed in: 07.12

Description: It is possible to see patients on the name search that have been deleted in CRIS. These are patients who were created from a HIS record and were then deleted on CRIS.

211131 - Viewlog Missing entriesReported in: 06.12   Fixed in: 07.12

Description: If a patient is loaded from a worklist such as day list or report info list by selecting the dictate action while the user is in dictation mode then an entry is not added to the patient view "VIEWLOG" table to show that they loaded the event.

211157 - HIS Details not displaying demographic history correctlyReported in: 06.12   Fixed in: 2.09.10a

Description: If a patients name is updated then the demographic history on the patient details page shows the correct list of changes, where as on the HIS Details page which also shows the demographic history it does not show the change dates and change users correctly.

202701 - Null pointer error on unlinking patientReported in: 06.12   Fixed in: 07.12

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 28 of 47

Page 29: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

Description: On a patient which is not currently linked to a PAS patient when the user presses the unlink button a null pointer error is displayed rather than a nice message informing why the patient could not be unlinked. The unlink button should be disabled if the user is not linked to a pas record.

214516 - Incorrect terminology when matching a patientReported in: 06.12   Fixed in: 2.09.10a

Description: When matching a CRIS patient to a HIS record a confirmation box appears displaying the differences between the HIS and CRIS patient. If the demographics details or NHS number on the CRIS and PAS record differ then after clicking OK another dialogue appears warning the patient that the details are different with a 'Confirm Merge' tick box which should say 'Confirm Match'.

200778 - Move hospital numbers between merged patientsReported in: 06.12   Fixed in: 07.12

Description: When two patients have been merged that have a hospital number at the same site, these hospital numbers cannot be moved between the merged patients using the right click, move to patient functionality, as the numbers are at the same site.

218623 - Circular Link in Merge ChainReported in: 06.12   Fixed in: HEAD

Description: It is possible to create a circular merge chain in CRIS if both the patients to be merged are already loaded in different instances of CRIS.

212389 - Patient DOB validationReported in: 06.12   Fixed in: 2.09.10a

Description: The DOB validation for dates in the future is not performed on the patient search page. This can allow patients to be created with future dates of birth.

206640 - Incorrect Patients loaded using Accession NumberReported in: 06.12   Fixed in: 2.07.12a

Description: If a user tries to load a patient by entering an eight digit hospital number or accession number into the CRIS number field then there is a possibility that a different patient will be displayed than expected if there is another record that contains a matching accession or hospital number.

200616 - Flagging possible duplicates in patient searchReported in: 06.12   Fixed in: 07.12

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 29 of 47

Page 30: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

Description: The functionality to right click on a patient search to mark patients as possible duplicates with another patient no longer records the potential duplicate patients in the log which would be used for later investigation.

212979 - Blank HospNo field on patient search for PAS patients with a hospital numberReported in: 06.12   Fixed in: 2.09.10a

Description: When searching for patients using the hospital number search and multiple patients are found with this hospital number the PAS patients do not display their Hospital number. Performing a search on surname and forename will display their hospital number.

5.2.12 Post Processing

206719 - Unable to Post Process from Report Info list (unallocated)Reported in: 06.12   Fixed in: 2.07.12a

Description: Users are unable to Post Process an event if selecting from the Report Info List when the unallocated tick box is selected.

This produces a NULL pointer exception error message.Incident No. FJ 280542

200672 - Numeric entry in mAs fieldReported in: 06.12   Fixed in: 07.12

Description: The mAs field is automatically calculated from the mA and Secs fields. This causes problems when using the on screen numeric keypad. This results in the number entered using the keypad being appended to value automatically calculated from the mA and Secs fields. The user can use the keyboard to enter values as normal.

200528 - Projection details without a projection type are allowed to be savedReported in: 06.04   Fixed in: 07.12

Description: In post processing a projection line with no projection code is used to indicate that that projection line should be removed. CRIS should also prevent the creation of a projection line with no projection code and warn the user that the projection line will not be saved.

208289 - Post Processing symbol left on eventReported in: 06.12   Fixed in: 2.07.12a

Description: This occurs when the event is being post processed then the users goes back to the events details screen and clicks the undo attend button.Incident No. HSS 208207

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 30 of 47

Page 31: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

202151 - Post processing start timeReported in: 06.12   Fixed in: 07.12

Description: The post processing start time can sometimes default to earlier than the attendance time if the exam is performed quickly.

5.2.13 Printing

205529 - Ability to change font and font sizeReported in: 06.12   Fixed in: 07.12

Description: In printing, the entire letter content is produced by one template (letter) in one content area. However, font and font size can only be specified per content area, so the entire letter content is always in the same font and font size (usually Arial 11pt).

Some sites would like to use different fonts and font sizes, e.g. for information of different importance.

205554 - Page Preview in Print Content Editor does not inform user of parse errorsReported in: 06.12   Fixed in: 07.12

Description: The preview options in the Print Content Editor are used not only to preview the output but verify the Velocity code. The Template Preview option tells the user in a dialog box if there is a parse error in the Velocity code. However the Page Preview option does not.

204691 - Flexiforms with lookup table entry fields do not print prefix/suffixReported in: 06.04   Fixed in: 07.12

Description: All data entry fields can have a prefix (brief) and suffix. However this is only printed for non-lookup table fields.

203556 - Hospital cancel and reappointment letter does not mention changeReported in: 06.12   Fixed in: 07.12

Description: Appointments cancelled for hospital reasons, then reappointed, print the generic appointment letter with no mention of the previous appointment being changed.Incident No. 050I0224295

202862 - Ending a report line with ~ causes following text to not printReported in: 06.12   Fixed in: 07.12

Description: If a line of a report ends in the tilde character (~), then parts of the report text will not print correctly.

210544 - Labels marked as in comments on flexible forms print twice.Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 31 of 47

Page 32: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

Reported in: 06.12   Fixed in: 2.07.12a

Description: When a label is marked as to be displayed in the report comments, in a flexible form definition, it is inserted into the report text when the form is used, and it is not displayed on the flexible form. The label is still included in the flexible form printout however, when due to it being inserted as normal report text, there is no need.

201204 - Requests print appointment labelsReported in: 06.12   Fixed in: 07.12

Description: Right clicking on a request offers to print an appointment label. It should offer to print a request label.

201751 - Auto Capitalisation doesn't work well for postcodes or Scottish namesReported in: 06.12   Fixed in: 07.12

Description: Names like McName or MacName or O'Name do not convert to upper and lower case as a person would expect in letters when taken from the database which stores all names in uppercase.

5.2.14 Reporting

208499 - Possible to verify a report as another userReported in: 06.12   Fixed in: 2.07.12a

Description: When using the Verify action on the report page, the verified by user is set equal to the reported by user, which may be different to the current user. This means that one person can verify someone elses reports which could be a legal issue.

208638 - Unchecked and addended reports do not display in unverified list on report info screen.Reported in: 06.12   Fixed in: 2.07.12a

Description: If you have correctly added a name in the 'unchecked' field - these reports are identified via batch verify, with a 'u' as their status. You need to search using either no radiologists filter, or the radiologist who is identified in the unchecked field. However, they do not display in the unverified list of the report info list screen.

207465 - Reports saved with blank "reported_by"Reported in: 06.12   Fixed in: 07.12

Description: Some reports have been saved with a blank reported by value. This only occurs if the event has multiple exams AND the user enters a totally blank report with blank lines AND they have more than one copy of CRIS open AND the other copy of CRIS has not had a reporting session set.

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 32 of 47

Page 33: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

208009 - Coded phrases assigned to users not always being availableReported in: 06.04   Fixed in: 07.12

Description: If a user ID is different from the users login ID, when a coded phrase is assigned to their user ID, it does not always pop up in the F4 list when inserting the phrase into a report.

208010 - Tick box hover help on fetal anomaly report pagesReported in: 06.12   Fixed in: 2.07.12a

Description: Some of the tick boxes on the ANOMNW fetal anomaly report page either have no hover help or the wrong hover help.

213492 - Batch verify incorrectly populates reporting sessionReported in: 06.12   Fixed in: 2.09.10a

Description: If the reporting session has not been set then batch verify populates the reporting session with the clinician code entered in reported by.

212653 - Inaccuracy in Printing and viewing Obs GraphsReported in: 06.12   Fixed in: 2.07.12b

Description: When printing obs graphs, it has been noted the points can appear to move in relation to the graph curves when comparing the on screen and printed graphs. Investigation has shown that the plotted point is in exactly the same place, but the lines on the graph are not in the same place when viewed on screen and when printed.

212659 - Date last verifiedReported in: 06.12   Fixed in: 2.09.10a

Description: If a user selects a verified report and presses finished and save then the date last verified is updated to today's date even though the user has not made any changes and has not re-verified the report because it was already verified.

217151 - Verified status of different sections of a reportReported in: 06.12

Description: After a report has been verified, if a user un-verifies a single section then uses the 'verify' button on the right to reverify it the properties of each section within the report have details populated in the 'Last Verified' section even though strictly speaking only one section was altered.

216259 - Right click verify does not disable report editorReported in: 06.12   Fixed in: 2.09.10a

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 33 of 47

Page 34: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

Description: When you right click on a report and choose verify it is still possible to edit the report.

203309 - Useless Series Report Message sent to PACSReported in: 06.04   Fixed in: 07.12

Description: When using series reporting the reports that are part of this series are given the text: This attendance is part of a series Please see the report for event 123456

This therefore is the text that gets sent to PACS, but in PACS the event key is useless.Incident No. 226764

210388 - Some obstetric reports loading an invalid lookup tableReported in: 06.12   Fixed in: 2.07.12a

Description: Some of the obstetric report fields are trying to load a normal table that doesn't exist.

202800 - Null verification detailsReported in: 06.12   Fixed in: 07.12

Description: It is possible to get a verified report with no verification details, and also change the report text of a verified report by having 2 batch verification pages open at the same time.

210916 - Verified reports with blank verified by.Reported in: 06.12   Fixed in: 2.07.12b

Description: The report verified by value can be left blank after a report has been verified. Two radiologists load the same report into batch verify and the second radiologist ignores the warning saying that they are doing something potentially dangerous. Then the first radiologist modifies and verifies the report unaware of what the second radiologist is doing. The second radiologist then modifies and verifies the report again ignoring another warning that the report has been modified by someone else. This second save has wrongly removed the verified by code.

210203 - Merge eFilm PACS DTI ClearReported in: 06.12   Fixed in: 2.07.12a

Description: Sites using the Merge eFilm PACS would like a clear message sent to the PACS when the patient is cleared from CRIS so that the images are no longer displayed on the PACS.

204817 - Exhausted resultset saving NW anomaly obs reportLast Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 34 of 47

Page 35: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

Reported in: 06.12   Fixed in: 07.12

Description: On saving a report with heart abnormalities and report text, an error dialog appears. Also happens with no abnormalities and two invasive invests The invasive location disappears on re-saving Not possible to blank out any abnormalities

204541 - Unverifying during batch verify session for obstetric examsReported in: 06.12   Fixed in: 2.07.12a

Description: When using batch verify on obstetric exams the user cannot undo the verify action on an obstetric exam by using the right click option on the verify list.

209543 - Obstetric report changed values not saved warningReported in: 06.12   Fixed in: 2.07.12a

Description: If a user changes values on an obstetric report and clears without saving then they do not get a warning message that they have not saved their changes. Additionally it is possible to print the report without saving by using the right click menu.

209551 - EDD not shared on new multiple-fetus obstetric reportsReported in: 06.12   Fixed in: 2.07.12a

Description: On a new pregnancy with multiple fetuses, if the user uses add fetus to create the second fetus's report page before entering the EDD for the first fetus then the second fetus does not use the EDD already calculated on the first fetus. CRIS should always use any EDD already calculated unless this is changed by the user.

209835 - Fife obstetric anomaly report layout problem at low resolutionsReported in: 06.12   Fixed in: 2.07.12a

Description: The soft markers field no longer fits on 1024x768 screens if the amniocentesis option is selected.

209855 - Post Exam Auto Report reported byReported in: 06.12   Fixed in: 2.07.12a

Description: Once a user has used the "Auto Report" option in post exam then any subsequent reports they create using the report editor page are also saved as reported by "AUTO" rather than reported by the user.

204213 - Reports with no reporting radiologist.Reported in: 06.04   Fixed in: 07.12

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 35 of 47

Page 36: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

Description: When a report is typed from a dictation the radiologist code assigned to the report is always obtained from the dictation. If a user who is not configured with a radiologist code creates a dictation then when the report is typed the radiologist code assigned to the report is the blank code from the dictation. This would mean that the report would never appear on any radiologists batch verify list. It also prevents reports from printing correctly.

202508 - Duplicates on Report Info ListReported in: 06.12   Fixed in: 07.12

Description: If you select both Show Unallocated and Show Selected when in the report info list, and then have blank radiologist selected, it returns two results for each patient.Incident No. CSC - HD118394

202766 - Voice recognition insert phraseReported in: 06.12   Fixed in: 07.12

Description: On the first report since login the "insert phrase" VR command asks the user to confirm their radiologist code rather than assume the users default code when they have one.

201214 - Filtering Diagnosis Code Help.Reported in: 06.12   Fixed in: 07.12

Description: When entering a diagnosis code the filter field on the F4 prompt list has no effect.

212043 - Auto report with end dated Clinician codeReported in: 06.12   Fixed in: 2.07.12d

Description: If you auto report an event using a user with an end dated Clinician code and a coded phrase that will verify the report then the verified_by field is populated with the end dated Clinician code.

212050 - Batch Auto Report/Track screen is inadvertently closed when loading an event from the Report Info ListReported in: 06.12

Description: The Batch Auto Report/Track screen is inadvertently closed when selecting an Unreported event from the Report Info list (doble clicking the Event or selecting Change).

5.2.15 Scanning

203155 - Rescanning images other than REQCARD type uses REQCARD settingsReported in: 06.12   Fixed in: 07.12

Description: If any image type (MRI,PREGNANCY etc) is rescanned, other than REQCARD,

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 36 of 47

Page 37: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

the image is rescanned using the REQCARD settings.

203162 - Deleting or rescanning request cards causing save problems.Reported in: 06.04   Fixed in: 07.12

Description: If a request card image is deleted or rescanned and the next scan done is by two separate users at exactly the same time then one of the scanned images can replace the other and one is effectively lost. This does not always happen and is very time critical to make the issue occur.

212996 - can't delete or rescan corrupt scanned imagesReported in: 06.12   Fixed in: 2.09.10a

Description: If an image is scanned and for some reason there is a problem with the image so that there is no valid image available it is not possible to delete the request card record from the event. It is also not possible to rescan the request card to update the missing image.

5.2.16 Setup Tables

200725 - Closed Setup Tables reopenReported in: 06.12   Fixed in: 07.12

Description: If a setup page is opened and closed and then the user expands a node in the Setup Tables then the previously opened and closed tab will reopen.

212388 - Copying Appointment Diary Weeks on wrong daysReported in: 06.12   Fixed in: 2.09.10a

Description: When you copy an existing appointment diary for whole weeks CRIS is supposed to take the week you are copying and copy it exactly as it is to the destination week, Monday to Monday, Tuesday to Tuesday etc. It does not always do this if you have part weeks defined or you set the start date to a day other than Monday or the date you have selected for copying is not a Monday.

200542 - Cannot End Date Radiologist in Staff TablesReported in: 06.04   Fixed in: 2.09.10a

Description: Filling in the end date in the staff table for radiologist or Radiographer does not save unless another field is changed at the same time.

If you end-date the radiologist or radiographer in their own setup table this is correctly reflected in the staff table.Incident No. CSC - G150075009

202943 - Possible to create multiple blank radiologistsLast Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 37 of 47

Page 38: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

Reported in: 06.12   Fixed in: 2.07.12a

Description: The radiologists table has a unique index on code. However it is still possible to create multiple entries in the radiologists table with blank codes.

210875 - Validate Days of Week in Exams Per HospitalReported in: 06.12   Fixed in: 2.09.10a

Description: Need to validate the Days of Week and OV Days of Week fields in the exams per hospital table.

202406 - Signed fields in setup tables which should be unsignedReported in: 06.12   Fixed in: 07.12

Description: The following fields are signed and allow negative values and should only allow positive values. For ARSAC limits, dosages, time and weight, offsets etc, these could cause issues in further calculations.

PostExamDefaults: Quantity Used, Concentration ExaminationCodes: Max Wait, ARSAC Limit, Real Time, Male Dose, Female Dose Diary Setup: Room slot max patients value ExamsPerHospital: Max Wait, Procedure Time, Preparation Time, Number of Visits, Visit Frequency

202030 - StatsDatafld not saving but no error messageReported in: 06.12   Fixed in: 07.12

Description: If a new StatsDatafld is added to the system using the setup table, with a "Table" value of more than 48 characters but no other values, when it is saved, the error message informing the user that a field is too large is not displayed

201942 - New user group trust not validated.Reported in: 06.12   Fixed in: 07.12

Description: When creating a new user security group the trust field is not restricted to the trusts in the prompt table. Any value can be entered as a trust. If a group is created with an invalid trust it cannot be added to a user.

201506 - Deleting Entries in Exams Per Hosp SetupReported in: 06.12   Fixed in: 07.12

Description: If you have a modality selected in the exams per hospital setup table and delete one of the entries then the page is refreshed ignoring the modality selected and re-displays all exams for all modalities.

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 38 of 47

Page 39: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

201178 - Flexiforms cache is not refreshed when Refresh Tables is selectedReported in: 06.12   Fixed in: 07.12

Description: The Refresh Table selection does not refresh the Flexiforms help list correctly when inserting but not saving a new form The help list only gets refreshed when the application is shut down and restarted.

200872 - Changing a security setting can update more than one value.Reported in: 06.12   Fixed in: 07.12

Description: If User security role protection is disabled then changing a setting to "N" can change another unrelated setting to N if the table has been re-sorted into a different order by pressing the title button of one of the columns.

200866 - The same warning displayed four times on the Log In ID fieldReported in: 06.12   Fixed in: 07.12

Description: When an illegal character is used in the Log In ID field the warning message 'Log In ID contains invalid characters' is correctly displayed. However when accepted the same message is then displayed a further three times.

203290 - Blank grey areas in MOD_JAVA message of the dayReported in: 06.12   Fixed in: 07.12

Description: When html in the message of the day is wrapped due to being wider than the display, a grey area is rendered above the message of the day roughly equal in height to the wrapped section.

218863 - Translation table not saving changesReported in: 06.12

Description: It is not possible to change the CRIS code or Foreign code for an entry in the translation table setup.

208076 - View Only GroupsReported in: 06.12   Fixed in: 2.07.12a

Description: Users with a view only user group can perform some actions that update data. They also have the ability to print letters, labels and documents.

205029 - Cannot add new exam code without filling in DWT fieldReported in: 06.12   Fixed in: 07.12

Description: When adding a new exam code the DWT field should be defaulted to 'N' (in the database it is), but because the field is specified in the insert statement, if it is left blank, this

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 39 of 47

Page 40: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

displays an error informing that a null value cannot be entered into the field. The user should not have to fill this DWT field in for each exam code, it should be defaulted to 'N'.

208713 - Coded Phrase trust code problemsReported in: 06.12   Fixed in: 2.07.12a

Description: It's not possible to change the trust code of a coded phrase from blank to the current trust.

206102 - Can't delete values from Normal tableReported in: 06.12   Fixed in: 07.12

Description: Users cant delete a value from tables such as CRISREAC if the code contains trailing or leading spaces.

209165 - Scottish Bank HolidaysReported in: 06.12   Fixed in: 2.07.12a

Description: Most bank holidays used in CRIS are defined as the English set of bank holidays. Scottish bank holidays are currently not treated correctly by CRIS.

206751 - ExamCodesPerHospital Letter field lists letters for current site not selected siteReported in: 06.12   Fixed in: 2.07.12a

Description: In the exams per hospital table, when pressing F4 on the LETTER field, it will only produce a list of the letters assigned to the site code you are logged in as rather than the sitecode of the site you have selected in the exams per hospital tableIncident No. 280560

209314 - CRIS MOBL - Able to add Code of more than 1 characterReported in: 06.12   Fixed in: 2.07.12a

Description: It is possible to enter a code of 2 characters into the CRISMOBL normal table even though the database field length is only 1 character. Add a warning message to the normal tables setup table that stops codes longer than 1 character being created in the CRISMOBL table.

204042 - Multi Line Phrase SetupReported in: 06.12   Fixed in: 07.12

Description: In the report phrase setup it is possible to create a phrase split into several lines. When this is reloaded for modification in the setup tables it appears to have been joined into one line. If the phrase is used however it is actually still split over several lines

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 40 of 47

Page 41: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

209018 - Department hover help in the Rooms SetupReported in: 06.04   Fixed in: 2.07.12a

Description: Table Setup > Places > Rooms.

In the department field if you select a department, it populates the field fine but in the hover help it will display the site code for the department at the top of the list.Incident No. FJ 050I0306662

5.2.17 Statistics

207715 - Foreign fields in output fields of stats don't perform null checks.Reported in: 06.12   Fixed in: 07.12

Description: Even if the fields that make up a foreign field in stats have the relevant null flags set, the checks still aren't performed. This means that a blank value is returned for some fields such as the DICTATE.By Name field, instead of the value against the blank code, which would be "Blank Radiol".

209084 - Removing multiple selection criteria in stats.Reported in: 06.12   Fixed in: 2.07.12a

Description: If multiple selection criteria are selected in stats, and the selected nodes contain brackets, when the remove button is pressed, the criteria is not removed and null pointers are thrown in the Java console. This can then prevent the removing of other selection criteria on the page.

209111 - Popup table displayed on valid selection criteria.Reported in: 06.04   Fixed in: 2.07.12a

Description: When selection criteria has been added to a stat such that one field = another field, if the focus is lost, either by clicking on the operator field, or by pressing tab, the popup table is displayed (if there is one set). Other selection criteria can set selected, or return can be pressed and the pop up does not appear.

209146 - Linking tables being inserted when auto joins are not to be used.Reported in: 06.04   Fixed in: 2.07.12a

Description: When the "use auto joins" check box is not selected in stats, the links between the tables are not automatically inserted, however, the tables that the system believes are required for the auto joins are still inserted into the query. This results in invalid large queries, as even though the auto join links are not present, the tables are, and what is more, they no longer have a link to them as the system is not adding them automatically.

Also, if auto join links is not selected, if there is no selection criteria for the auto joined links, the system thinks we are still using them.

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 41 of 47

Page 42: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

214857 - Stat selection of foreign field >= blank value gives errorReported in: 06.12   Fixed in: 2.09.10a

Description: Selection criteria of where a foreign field >= blank value gives an error message and does not work.

206418 - Invalid query error on single foreign field selection in statsReported in: 06.12   Fixed in: 07.12

Description: When in stats, if a single selection criteria is entered, on a field that is a foreign field (a field in a different table), the stat fails and a message appears informing that the query performed was invalid

206194 - Saving output format in stats leaves blank output on statReported in: 06.12   Fixed in: 07.12

Description: If an output template is saved from an existing stat, either a template or a previously run stat, then the stat template as a whole is saved immediately afterwards, and the overwrite option is selected, the stat is displayed with no output format on screen, and none in the database.

206806 - Selecting end dated codes in statsReported in: 06.12   Fixed in: 07.12

Description: The lookup lists in CRIS normally remove any end dated codes as they should no longer be used. This functionality has been copied across to the lookups in the stats module, however, stats are run retrospectively and it is possible that end dated codes need to be able to be selected to run stats on them.

206384 - <> operator on nullable fields in statsReported in: 06.12   Fixed in: 2.07.12

Description: When a field can be nullable, and the <> operator is used on a value, the null values are not included in the list of results. This is only a problem when using a specified value, not when using join on two fields

206368 - Stats version, date and update dateReported in: 06.12   Fixed in: 07.12

Description: There is no way for a trust to currently know what version of the stats package they have on their system. It would be useful if it was displayed to them somewhere. This would include the version number, the date of the version, and the date their system was updated.

201550 - Stopping stats on log out / shutdownLast Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 42 of 47

Page 43: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

Reported in: 06.12   Fixed in: 07.12

Description: When a stat is running locally on a client, if the user shuts down CRIS or logs out and restarts, the stat is still set as running. If the stat is selected from the previous stats screen, the option is there to stop the stat, but no one is able to as no one controls the thread that belongs to the stat. The thread has in fact been shutdown at the same time the application was, and the stat query also stopped at this point. The stat should in fact have its status set to stopped when this happens, rather than still appearing as running.

202815 - Stats "in" Operator on selection Criteria of derived fieldsReported in: 06.12   Fixed in: 07.12

Description: When using a derived field in statistical reporting, the "in" operator does not return results that contain the value entered.

202820 - Changing "look and feel" theme to "windows" breaks display of statsReported in: 06.04   Fixed in: 07.12

Description: When changing the look and feel of CRIS, the stats page does not display correctly, fields cannot be read.Incident No. HSS REF 202818

210621 - ~ is not handled the same in stats as in reporting.Reported in: 06.12

Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also displayed as single tilda. This is true for all cases that are not control characters. The viewer for stats has not been changed to reflect this however, and so is inconsistent with the report view.

212292 - Stats report viewer doesn't handle ~(Reported in: 06.12

Description: The stats report viewer doesn't handle ~( well. If a matching closing bracket is found then only the details contained within the brackets is missing from the output when viewed in the viewer, however if there is a ~( with no matching bracket, the viewer displays nothing.

202878 - Selecting from prompt table problemReported in: 06.12   Fixed in: 2.07.12a

Description: When there is a prompt table used in the statistical reporting selections, that is large enough to require a scroll bar to view all entries, selecting an entry in the list actually selects the next row in the table.

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 43 of 47

Page 44: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

204321 - To use "Stop Stat" button stat, has to be reselected from previous stats screenReported in: 06.12   Fixed in: 07.12

Description: In order to stop a running stat, it has to be selected from within the previous stats screen. This means once a stat has been loaded and started to run, the user cannot just press "Stop Stat", they have to find the stat in the previous stats screen and reselect it. This could be made slicker by enabling a user to press "Stop Stat" as soon as they have press "Run Stat"

204371 - View and Print stat button disablingReported in: 06.12   Fixed in: 07.12

Description: The view and print buttons are available when a stat template is loaded, when the template was created from a previously run stat. The view and print buttons should never be enabled when a template has been loaded, as there will never be any stat output files created for a template.

204943 - Case sensitivity on type "L" datafieldsReported in: 06.12   Fixed in: 07.12

Description: The datafield type of "L" is used for large text objects, as these can only have the operator of "in" applied to selections on them. The text stored within these database fields however, can be both upper and lower case, but the only datafields that are affected by case sensitivity are those marked as type "A" for ascii. Both types of "A" and "L" need to be affected when they are marked as being case sensitive.

203391 - No output format error message breaks run stat buttonReported in: 06.12   Fixed in: 07.12

Description: If a new stat is created from scratch and attempted to run before an output format type is selected, the appropriate error message pops up. However if the user selects no to continue the run, selects an output type, and then selects run again, nothing happens.

5.2.18 Stats Scheduler

201188 - No message to the user if the report file cannot be FTP'd to the remote serverReported in: 06.12   Fixed in: 07.12

Description: When sending a report from the database server to a remote server, if the file transfer is not completed an error message is not generated in the application.

212061 - Stopping long stats with large sql queryReported in: 06.12   Fixed in: 2.07.12b

Description: The query which currently gets long running stats in order to warn or stop them when they will take too long to complete, uses the gv$sql.sql_text field. This field does not always return the required full query, but only the first 1000 characters. This can mean that the

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 44 of 47

Page 45: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

text returned does not always contain all the information required, and long running stats are not always stopped.

203392 - Date expansion in the scheduler start date and end date fieldsReported in: 06.12   Fixed in: 07.12

Description: The date expansion does not automatically happen in the start date and end date fields on the statistical reporting scheduler page

5.2.19 Voice Recognition

206299 - Assigned Dragon VR User Changing.Reported in: 06.12   Fixed in: 07.12

Description: Occasionally a CRIS users assigned Dragon id seems to change to someone else's.

201872 - Voice recognition disabled icon after clear patient command.Reported in: 06.12   Fixed in: 07.12

Description: Using the "Clear Patient" command in voice recognition incorrectly changes the CRIS microphone icon to show the microphone off icon.

204486 - Abnormal application termination with Voice Recognition enabledReported in: 06.12   Fixed in: 07.12

Description: The application abnormally terminates (VR is enabled) when the X is pressed on the Continue Without Voice Recognition ...... Show Report dialogue which is shown if a user tries to load the report editor before Dragon has finished loading.

208435 - Correction menu fails to close after correctionsReported in: 06.12   Fixed in: 2.07.12a

Description: The pop-up correction menu, triggered by the 'correct that'/'correct [word]' command will on occasions remain open after corrections have been made. This seems to occur when Dragon misinterprets correction menu commands, such as 'choose two' or registers other input as valid dictation and continues entering text into CRIS. The only way to close the correction menu after this happens is by clicking on the application window.

218587 - Wrong profiles loaded/savedReported in: 06.12

Description: It is possible for a user to get the wrong VR profile loaded and assigned to them.

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 45 of 47

Page 46: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

If the users profile is corrupt then VR will fail to load that profile and load the previous profile loaded.

205785 - Assigning Dragon user to new CRIS userReported in: 06.12   Fixed in: 07.12a

Description: If a CRIS user who has not been assigned a Dragon user logs into CRIS in Voice recognition mode then CRIS will ask Dragon for a Dragon user id to tie to the CRIS user. If the user cancels the Dragon dialogue box without selecting a new Dragon user then CRIS will use the same Dragon user as was previously open on this PC.

205783 - Dragon User displayed on microphone iconReported in: 06.12   Fixed in: 2.07.12a

Description: On a workstation configured to use voice recognition the VR microphone icon at the top has a hover help so that it shows the Dragon user id loaded. When the user logs out and another user logged in then this hover help shows the previous user ID until either the user navigates to the report page or presses the microphone button to turn on or off the microphone.

5.2.20 Worklists

207233 - Dictation untyped incorrect figuresReported in: 06.12   Fixed in: 2.07.12a

Description: The 'Total Number of Untyped Dictations' displayed on the Dictation List page includes dictation with a status of 05LOCK, these should not be counted as they are not ready for transcription.

200586 - Hover help does not work correctly on the Porters ListReported in: 06.12   Fixed in: 07.12

Description: Some of the hover helps on the Porter List do not display the code description.

201868 - New patient matching on order selectionReported in: 06.04   Fixed in: 07.12

Description: When an order is selected for a pas patient who has not previously been registered on CRIS, then CRIS does not perform the match test to check if this patient already exists on CRIS.Incident No. CSC HD91590 This issue has been resolved in CRIS 06.12f

202228 - Dictation list orderReported in: 06.12   Fixed in: 07.12

Description: The dictation list does not always return the oldest dictations when there is a max

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 46 of 47

Page 47: Appointments - Home | Wellbeing Software€¦  · Web viewReported in: 06.12 Description: When using ~ in a report, single ~ are displayed as single tilda, and double tilda is also

The Radiology Information Solution

limit set. It returns a number of dictations that match the selected criteria up to the max number set but of Oracles choosing which can be random and not always the oldest.

205231 - Batch verify list report buttonReported in: 06.12   Fixed in: 07.12

Description: The report button on the batch verify list takes the user to the report that was selected. However if a list is loaded the button is disabled until a report is selected. If another batch verify search is then performed, the button is still enabled, and when pressed would take the user to the report screen for the old report that was selected. Each time no report is selected in the list, the buttons should be disabled, not do the action on the previously selected event

200761 - Report info list date expansionReported in: 06.04   Fixed in: 07.12

Description: The start date and end date fields on the report info list do not auto format the date into the dd/mm/yyyy format.

209383 - Report info list fetches all results before refreshing listReported in: 06.12   Fixed in: 2.07.12a

Description: The unreported list fetches all the results for the specified search criteria before updating the list. It should fetch 5 days worth of data at a time and update the list in between queries.

Last Updated: HSS 24/05/2023 Healthcare Software Systems – Commercial in Confidence Page 47 of 47


Recommended