+ All Categories
Home > Documents > Armstrong Air Heat Pumps - ECCO Supply · 2020. 7. 31. · system air conditioners and heat pumps...

Armstrong Air Heat Pumps - ECCO Supply · 2020. 7. 31. · system air conditioners and heat pumps...

Date post: 18-Feb-2021
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
11
ARMSTRONG AIR HEAT PUMPS www.armstrongair.com Revised: June 2016 • Replaces: May 2013 Expert Service. Quality Products. Since 1960. www.eccosupply.ca 5-1 ECCO Supply™ INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM — EFC/EFV............................................................................. 5-10 ELECTRIC HEAT KITS..................................................................................................................................................... 5-11 EVAPORATOR COILS EC1P / EM1P — UPFLOW / COUNTERFLOW APPLICATIONS AND UPFLOW / HORIZONTAL APPLICATIONS (CASED) ........................................................................ 5-6 – 5-7 EH1P — DEDICATED HORIZONTAL APPLICATIONS (CASED) ................................................................... 5-9 EU1P — UPFLOW / COUNTERFLOW APPLICATIONS (UNCASED) ........................................................... 5-8 SPLIT SYSTEM HEAT PUMPS 4SHP13LE — ENHANCED ........................................................................................................................................ 5-2 4SHP14LE — ENHANCED ........................................................................................................................................ 5-3 4SHP16LT — ENHANCED ........................................................................................................................................ 5-4 4SHP18LT — ENHANCED ........................................................................................................................................ 5-5 TXV KITS ............................................................................................................................................................................ 5-11 For Technical and Warranty Information visit www.armstrongair.com
Transcript
  • ARMSTRONG AIR HEAT PUMPSwww.armstrongair.com

    Revised: June 2016 • Replaces: May 2013

    Expert Service. Quality Products. Since 1960.

    www.eccosupply.ca 5-1ECCO Supply™

    INDEXELECTRIC FURNACE MODULAR AIR SYSTEM — EFC/EFV ............................................................................. 5-10ELECTRIC HEAT KITS ..................................................................................................................................................... 5-11EVAPORATOR COILS

    EC1P / EM1P — UPFLOW / COUNTERFLOW APPLICATIONS AND UPFLOW / HORIZONTAL APPLICATIONS (CASED) ........................................................................ 5-6 – 5-7EH1P — DEDICATED HORIZONTAL APPLICATIONS (CASED) ................................................................... 5-9EU1P — UPFLOW / COUNTERFLOW APPLICATIONS (UNCASED) ........................................................... 5-8

    SPLIT SYSTEM HEAT PUMPS4SHP13LE — ENHANCED ........................................................................................................................................ 5-24SHP14LE — ENHANCED ........................................................................................................................................ 5-34SHP16LT — ENHANCED ........................................................................................................................................ 5-44SHP18LT — ENHANCED ........................................................................................................................................ 5-5

    TXV KITS ............................................................................................................................................................................ 5-11

    For Technical and Warranty Information visit www.armstrongair.com

  • ARMSTRONG AIR HEAT PUMPS

    www.armstrongair.com

    – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

    ECCO Supply™5-2 www.eccosupply.ca

    Revised: June 2015 • Replaces: May 2013

    SPLIT SYSTEM HEAT PUMPS4SHP13LE — ENHANCEDCompressor• High efficiency scroll compressor• R410a refrigerant• Grommet mounted compressor for quiet

    operation• Internally protected against high temperature

    motor overload conditions• Heavy duty compressor sound blanket for quiet

    operation

    Design• Designed for ambients up to 125°F

    Coil• Enhanced aluminum fins and copper

    tubing for high efficiency and capacity• Raised coil prevents debris from

    collecting in bottom of coil and causing loss of airflow

    Accessories• Low ambient kit• Crank Case Heater• Freezestat

    ITEM # MODEL DIMENSIONS (")W D H

    COOLING CAPACITY

    (TONS)VOLTAGE/ HZ/PHASE

    SHIPPING WEIGHT (LBS)

    C894148 4SHP13LE118P 24.75 26.75 33.75 1.5 208-230/60/1 169894352 4SHP13LE124P 24.75 26.75 33.75 2.0 208-230/60/1 174894354 4SHP13LE130P 29.38 31.25 29.75 2.5 208-230/60/1 185894356 4SHP13LE136P 29.38 31.25 37.75 3.0 208-230/60/1 208894358 4SHP13LE142P 29.38 31.25 43.75 3.5 208-230/60/1 253894360 4SHP13LE148P 29.38 31.25 33.75 4.0 208-230/60/1 257894362 4SHP13LE160P 29.38 31.25 37.75 5.0 208-230/60/1 279

    NOTE: Weights listed are unit weights with packaging. Dimensions listed are unit sizes without packaging.

    4SHP13LE

    Split System Heat Pump 4SHP13LE

    UnitDimensionsandSoundRatings

    ModelNumberGuide

    PhysicalandElectrical

    4 SHP 13 LE 1 24 P - 5 A

    4 - R410a Minor Revision Code

    Split Heat Pump Major Revision Code

    13 - 13 SEER NominalVoltageP - 208-230v/60hz/1Ph

    Louvered Enhanced Nominal Capacity

    Series24 - 24,000 Btuh

    ModelVoltage/

    HZ/ Phase

    Voltage Range

    Min. Circuit Amp.

    Max. Over

    current Device (amps)

    Compressor Fan MotorRefrig.

    Charge+ (oz.)

    Shipping Weight (lbs.)

    Rated Load

    (amps)

    Locked Rotor

    (amps)

    Rated Load

    (amps)

    Rated HP

    Nom. RPM

    Wire Guard

    Louvered

    4SHP13LE118P-5 208-230/1/60 197 - 253 11.9 20 9.0 48 0.7 1/10 1075 106 NA 169

    4SHP13LE124P-5 208-230/1/60 197 - 253 14.2 20 10.7 53 0.8 1/10 1075 101 NA 174

    4SHP13LE130P-5 208-230/1/60 197 - 253 16.3 25 12.4 59 0.7 1/6 825 108 NA 185

    4SHP13LE136P-5 208-230/1/60 197 - 253 19.9 35 15.2 70 0.9 1/6 825 114 NA 208

    4SHP13LE142P-5 208-230/1/60 197 - 253 27.8 45 21.1 90 1.4 1/4 825 134 NA 253

    4SHP13LE148P-5 208-230/1/60 197 - 253 31.7 50 24.1 100 1.5 1/4 825 198 NA 257

    4SHP13LE160P-5 208-230/1/60 197 - 253 36.3 60 27.6 120 1.7 1/3 825 210 NA 279

    Model No.Dimensions (inches) Sound

    Ratings (dBA)A-Width B-Depth C-Height

    4SHP13LE118P-5 24.75 26.75 33.75 75

    4SHP13LE124P-5 24.75 26.75 33.75 74

    4SHP13LE130P-5 29.38 31.25 29.75 74

    4SHP13LE136P-5 29.38 31.25 37.75 74

    4SHP13LE142P-5 29.38 31.25 43.75 76

    4SHP13LE148P-5 29.38 31.25 33.75 76

    4SHP13LE160P-5 29.38 31.25 37.75 76

    - Page 2-

    Note:Weights listed are unit weights with packaging.+ Factory charged for 15 feet of line set. Adjust per installation instructions.

    Note: Dimensions listed are unit sizes without packaging.

    Model Number Guide

  • ARMSTRONG AIR HEAT PUMPS

    www.armstrongair.com

    – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

    www.eccosupply.ca 5-3ECCO Supply™

    Revised: June 2015 • Replaces: May 2013

    SPLIT SYSTEM HEAT PUMPS (cont’d)4SHP14LE — ENHANCEDCompressor• High-efficiency scroll compressor• R410a refrigerant• Grommet-mounted compressor for quiet

    operation• Internally protected against high temperature

    motor overload conditions• Heavy-duty compressor sound blanket for

    quiet operation

    Design• Designed for ambients up to 125°F

    Coil• Enhanced aluminum fins and copper tubing for

    high efficiency and capacity• Raised coil prevents debris from collecting in

    bottom of coil and causing loss of airflow

    Accessories• High pressure cutout kit• Fossil fuel kit• Outdoor thermostat/low-ambient

    compressor cutout kit• Thermal expansion valve kits

    ITEM # MODEL DIMENSIONS (")W D H

    COOLING CAPACITY

    (TONS)VOLTAGE/ HZ/PHASE

    SHIPPING WEIGHT (LBS)

    894380 4SHP14LE118P 29.38 31.25 29.75 1.5 208-230/60/1 178894382 4SHP14LE124P 29.38 31.25 37.75 2.0 208-230/60/1 195894384 4SHP14LE130P 29.38 31.25 37.75 2.5 208-230/60/1 197894386 4SHP14LE136P 29.38 31.25 33.75 3.0 208-230/60/1 222894388 4SHP14LE142P 35.75 35.75 37.75 3.5 208-230/60/1 304894390 4SHP14LE148P 35.75 35.75 37.75 4.0 208-230/60/1 308894392 4SHP14LE160P 35.75 35.75 43.75 5.0 208-230/60/1 335

    NOTE: Weights listed are unit weights with packaging. Dimensions listed are unit sizes without packaging.

    14 SEER Split System Enhanced Heat Pump

    - Page 2-

    Model No.Dimensions (inch) Rating

    (dBA)A-Width B-Depth C-Height

    4SHP14LE118P-5 29.38 31.25 29.75 74

    4SHP14LE124P-5 29.38 31.25 37.75 74

    4SHP14LE130P-5 29.38 31.25 37.75 74

    4SHP14LE136P-5 29.38 31.25 33.75 74

    4SHP14LE142P-5 35.75 37.75 37.75 76

    4SHP14LE148P-5 35.75 37.75 37.75 76

    4SHP14LE160P-5 35.75 37.75 43.75 76

    ModelNumberGuide

    ModelVoltage/ Phase/

    Hz

    Voltage Range

    Min. Circuit Amp.

    Max. Over

    current Device (amps)

    Compressor Fan MotorRefrig.

    Charge+ (oz.)

    Shipping Weight (lbs.)

    Rated Load

    (amps)

    Locked Rotor

    (amps)

    Rated Load

    (amps)

    Rated HP

    Nom. RPM Wire Guard Louver

    4SHP14LE118P-5 208-230/60/1 197-253 12.3 20 9.0 48 1.1 1/6 825 87 NA 178

    4SHP14LE124P-5 208-230/60/1 197-253 17.9 30 13.4 58 1.1 1/6 825 108 NA 195

    4SHP14LE130P-5 208-230/60/1 197-253 17.1 25 12.8 64 1.1 1/6 825 110 NA 197

    4SHP14LE136P-5 208-230/60/1 197-253 18.7 30 14.1 77 1.1 1/6 825 159 NA 222

    4SHP14LE142P-5 208-230/60/1 197-253 24.2 40 17.9 112 1.8 1/3 825 184 NA 304

    4SHP14LE148P-5 208-230/60/1 197-253 29.0 50 21.8 117 1.8 1/3 825 232 NA 308

    4SHP14LE160P-5 208-230/60/1 197-253 29.4 50 22.1 125 1.8 1/3 825 228 NA 335

    4 SHP 14 LE 1 24 P - 5 A

    4 - R410a Minor Revision Code

    Split Heat Pump Major Revision Code

    14 - 14 SEER NominalVoltageP - 208-230v/60hz/1Ph

    Louvered Enhanced Nominal Capacity

    Series24 - 24,000 Btuh

    PhysicalandElectrical

    UnitDimensionsandSoundRatings

    Note: Dimensions listed are unit sizes w/o packaging

    Note: Weights listed are unit weights with packaging. + Factory charged for 15 feet of line set. Adjust per installation instructions.

    Model Number Guide

    Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR® criteria. Visit www.energystar.gov for details.

    Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR® criteria. Visit www.energystar.gov for details.

  • ARMSTRONG AIR HEAT PUMPS

    www.armstrongair.com

    – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

    ECCO Supply™5-4 www.eccosupply.ca

    Revised: June 2015 • Replaces: May 2013

    4SHP16LTSPLIT SYSTEM HEAT PUMPS (cont’d)4SHP16LT — ENHANCEDCompressor• High efficiency 2 stage Copeland UltraTechTM

    scroll compressor• R410a refrigerant• Grommet mounted compressor for quiet

    operation• Internally protected against high temperature

    motor overload conditions

    Design• Designed for ambients up to 125°F

    Coil• Enhanced aluminum fins and copper tubing for

    high efficiency and capacity• Raised coil prevents debris from collecting in

    bottom of coil and causing loss of airflow

    Factory Installed Accessories• Crank case heater• Compressor sound cover for quiet

    operation• High pressure switch• Low pressure switch for loss of charge

    protection

    ITEM # MODEL DIMENSIONS (")

    W D H

    COOLING CAPACITY

    (TONS)VOLTAGE/ HZ/PHASE

    WEIGHT (LBS)

    894368 4SHP16LT124P 24.75 26.75 33.75 2.0 208-230/60/1 207894370 4SHP16LT136P 29.375 31.25 37.75 3.0 208-230/60/1 253894372 4SHP16LT148P 35.75 37.75 37.75 4.0 208-230/60/1 288894374 4SHP16LT160P 35.75 37.75 43.75 5.0 208-230/60/1 313

    16 SEER Split System Heat Pump

    Unit Dimensions (in.) and Sound Ratings

    Model Number Guide

    Physical and Electrical

    4 SHP 16 LT 1 24 P - 2 A

    4 - R410a Minor Revision Code

    Heat Pump Major Revision Code

    16 - 16 SEER NominalVoltageP - 208-230v/60hz/1Ph

    Louvered Two Stage Nominal Capacity

    Series24 - 24,000 Btuh

    Model Voltage/Hz/PhaseVoltageRange

    Min.CircuitAmp.

    Max.Over

    currentDevice(amps)

    Compressor FanMotorRefrig.Charge(oz.)

    Weight(lbs.)Rated

    Load(amps)

    LockedRotor(amps)

    RatedLoad(amps)

    RatedHP

    Nom.RPM

    4SHP16LT124P-2 208-230-60/1 197-253 13.5 20 11.4 52 0.7 1/10 1075 146 207

    4SHP16LT136P-2 208-230-60/1 197-253 22.5 35 19.0 82 1.7 1/4 825 192 253

    4SHP16LT148P-2 208-230-60/1 197-253 28.2 45 24.0 96 1.8 1/3 825 236 288

    4SHP16LT160P-2 208-230-60/1 197-253 35.1 60 26.0 118 2.8 1/3 ECM 244 313

    ModelNo.Dimensions Sound

    RatingdBAA B C

    4SHP16LT124P-2 24-3/4 26-3/4 33-3/4 73

    4SHP16LT136P-2 29-3/8 31-1/4 37-3/4 75

    4SHP16LT148P-2 35-3/4 37-3/4 37-3/4 75

    4SHP16LT160P-2 35-3/4 37-3/4 43-3/4 74

    FPO

    - Page 2 -

    Model Number Guide

    Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR® criteria. Visit www.energystar.gov for details.

    Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR® criteria. Visit www.energystar.gov for details.

  • ARMSTRONG AIR HEAT PUMPS

    www.armstrongair.com

    – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

    www.eccosupply.ca 5-5ECCO Supply™

    Revised: June 2015 • Replaces: May 2013

    SPLIT SYSTEM HEAT PUMPS (cont’d)4SHP18LT — ENHANCEDCompressor• High-efficiency 2-stage Copeland UltraTechTM

    scroll compressor• R410a refrigerant• Grommet-mounted compressor for quiet

    operation• Internally protected against high temperature

    motor overload conditions• Heavy-duty compressor sound blanket for quiet

    operation

    Design• Designed for ambients up to 125°F

    Coil• Enhanced aluminum fins and copper

    tubing for higher efficiency and capacity• Raised coil prevents debris from collecting

    in bottom of coil and causing loss of airflow

    ITEM # MODEL DIMENSIONS (")W D H

    COOLING CAPACITY

    (TONS)VOLTAGE/ HZ/PHASE

    WEIGHT (LBS)

    894394 4SHP18LT124P 35.66 37.66 44 2.0 230/60/1 341894396 4SHP18LT136P 35.66 37.66 44 3.0 230/60/1 338894398 4SHP18LT148P 35.66 37.66 44 4.0 230/60/1 338894400 4SHP18LT160P 35.66 37.66 44 5.0 230/60/1 361

    SoundRatings

    Dimensions(in.)

    ModelNumberGuide

    PhysicalandElectrical

    4 SHP 18 LT 1 24 P - 1 A

    4 - R410a Minor Revision Code

    Split Heat Pump Major Revision Code

    18 - 18 SEER NominalVoltageP - 208-230v/60hz/1Ph

    Louvered Two Stage Nominal Capacity

    Series24 - 24,000 Btuh

    Model Voltage/Hz/PhaseVoltage Range

    Min. Circuit Amp.

    Max. Over

    current Device (amps)

    Compressor Fan Motor RefrigerantLine Connections Refrig. Charge

    (oz.)

    Weight (lbs.)Rated

    Load (amps)

    Locked Rotor

    (amps)

    Rated Load

    (amps)

    Rated HP

    Nom. RPM

    Liquid O.D. (in.)

    Vapor O.D. (in.)

    4SHP18LT124P-1 230-60/1 216-253 15.6 25 10.2 52 .7 1/3 825 3/8 7/8 300 341

    4SHP18LT136P-1 230-60/1 216-253 23.7 40 16.6 82 .6 1/3 825 3/8 7/8 283 338

    4SHP18LT148P-1 230-60/1 216-253 29.3 50 21.1 96 .8 1/3 825 3/8 7/8 262 338

    4SHP18LT160P-1 230-60/1 216-253 34.4 60 25.6 118 .8 1/3 825 3/8 7/8 274 361

    Model No.Sound Rating dBA

    4SHP18LT124P-1 72

    4SHP18LT136P-1 75

    4SHP18LT148P-1 75

    4SHP18LT160P-1 75

    Model No. A B C

    4SHP18LT124P-1 35.66 37.66 44

    4SHP18LT136P-1 35.66 37.66 44

    4SHP18LT148P-1 35.66 37.66 44

    4SHP18LT160P-1 35.66 37.66 44

    Highest achievable in product family offering

    - Page 2 -

    Model Number Guide

    Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR® criteria. Visit www.energystar.gov for details.

    Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR® criteria. Visit www.energystar.gov for details.

  • ARMSTRONG AIR HEAT PUMPS

    www.armstrongair.com

    – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

    ECCO Supply™5-6 www.eccosupply.ca

    Revised: June 2015 • Replaces: May 2013

    EVAPORATOR COILS• All piston coils are compatible with R22 or R410A• All drain pans are compatible with UV lights

    (cont’d on next page)

    Features• Cased• Upflow/Counterflow (EC1P) for application

    flexibility Upflow/Horizontal (EM1P) for application flexibility

    • Microban® antimicrobial additive in the drain pan to resist mold and mildew growth

    • One of the lowest water retention drain pans in the industry to minimize mold and mildew growth

    • Insulated steel coil case with high quality painted finish

    • Interlocking door assemblies and snug line seal grommets to minimize air leakage

    • External cabinet mounted distributor body designed for easy changing of orifice sizes and fast TXV connections

    • Foil-face insulation for easy cleaning• Two dual drain connections on front of coil

    for installation flexibility of drain lines around furnace vent and utility connections

    • Side drain pan built in for easy horizontal coil installations (EM1P only)

    • Tubing located at door split for easy coil service or coil cleaning

    E C 1P 18 A G - 1

    Model Number Guide

    E = Evaporator Coil

    C = Cased M = Multi-position

    U = Uncased H = Horizontal

    Expansion Device 1P = Piston

    4T = R410A AC or HP TXV w/check valve

    Nominal Capacity 18, 19 = 1.5 ton 23, 24 = 2.0 ton 29, 30 = 2.5 ton 35, 36 = 3.0 ton

    42 = 3.5 ton 43 = 3.5/4.0 ton

    48, 49, 50 = 4.0 ton 60, 61, 62 = 5.0 ton

    Series

    Color N = Not Applicable G = Platinum Gray M = Galvanized Embossed

    Matching Gas Furnace Cabinet Width A = 14.5 B = 17.5 C = 21 D = 24.5

    Model Number Guide

    EC1P EM1P

    EC1P / EM1P — UPFLOW / COUNTERFLOW APPLICATIONS AND UPFLOW / HORIZONTAL APPLICATIONS

  • ARMSTRONG AIR HEAT PUMPS

    www.armstrongair.com

    – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

    www.eccosupply.ca 5-7ECCO Supply™

    Revised: June 2015 • Replaces: May 2013

    EVAPORATOR COILS (cont’d)EC1P / EM1P — UPFLOW / COUNTERFLOW APPLICATIONS AND UPFLOW / HORIZONTAL APPLICATIONS (cont’d)

    ITEM # MODEL

    NOMINAL CAPACITY

    (TONS)

    REFRIGERANTCONNECTION

    LIQUID (") VAPOR (")WEIGHT

    (LBS)893421 EC1P24AG 2.0 3/8 3/4 37893400 EC1P24BG 2.0 3/8 3/4 40893401 EC1P29AG 2.5 3/8 3/4 47893422 EC1P30AG 2.5 3/8 3/4 45893423 EC1P30BG 2.5 3/8 3/4 46893416 EC1P30CG 2.5 3/8 3/4 50893424 EC1P36AG 3.0 3/8 3/4 49893425 EC1P36BG 3.0 3/8 3/4 51893426 EC1P36CG 3.0 3/8 3/4 55893436 EC1P43BG 3.5/4.0 3/8 7/8 60893434 EC1P43CG 3.5/4.0 3/8 7/8 63893427 EC1P48BG 4.0 3/8 7/8 52893417 EC1P48CG 4.0 3/8 7/8 55893428 EC1P49CG 4.0 3/8 7/8 72893429 EC1P50CG 4.0 3/8 7/8 66893431 EC1P60DG 5.0 3/8 7/8 66893430 EC1P62CG 5.0 3/8 7/8 76893432 EC1P62DG 5.0 3/8 7/8 77893479 EM1P23AM/AG 2.0 3/8 3/4 40893480 EM1P23BM/BG 2.0 3/8 3/4 40893471 EM1P24AG 2.0 3/8 3/4 42893481 EM1P24BG 2.0 3/8 3/4 42893487 EM1P29AG 2.5 3/8 3/4 40893488 EM1P29BG 2.5 3/8 3/4 41893472 EM1P30AG 2.5 3/8 3/4 42893473 EM1P30BG 2.5 3/8 3/4 42893474 EM1P36AG 3.0 3/8 3/4 57893475 EM1P36BG 3.0 3/8 3/4 57893476 EM1P36CG 3.0 3/8 3/4 57893483 EM1P43BM/BG 3.5/4.0 3/8 7/8 45893484 EM1P43CM/CG 3.5/4.0 3/8 7/8 45893477 EM1P48BG 4.0 3/8 7/8 48893485 EM1P48CG 4.0 3/8 7/8 48893486 EM1P50CM/CG 4.0 3/8 7/8 77

  • ARMSTRONG AIR HEAT PUMPS

    www.armstrongair.com

    – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

    ECCO Supply™5-8 www.eccosupply.ca

    Revised: June 2015 • Replaces: May 2013

    EVAPORATOR COILS (cont’d)• All piston coils are compatible with R22 or R410A• All drain pans are compatible with UV lights

    EU1P — UPFLOW / COUNTERFLOW APPLICATIONS

    NOMINALCAPACITY

    (TONS)

    REFRIGERANT CONNECTION

    LIQUID (") VAPOR (")ITEM # MODEL WEIGHT

    (LBS)893450 EU1P18AN 1.5 3/8 3/4 18893448 EU1P19AN 1.5 3/8 3/4 19893449 EU1P23AN 2.0 3/8 3/4 22893451 EU1P24AN 2.0 3/8 3/4 22893460 EU1P24BN 2.0 3/8 3/4 23893459 EU1P29AN 2.5 3/8 3/4 24893452 EU1P30AN 2.5 3/8 3/4 26893462 EU1P30BN 2.5 3/8 3/4 27893463 EU1P30CN 2.5 3/8 3/4 29893453 EU1P36AN 3.0 3/8 3/4 31893454 EU1P36BN 3.0 3/8 3/4 33893464 EU1P36CN 3.0 3/8 3/4 34893467 EU1P43BN-1 3.5/4.0 3/8 7/8 43893468 EU1P43CN-1 3.5/4.0 3/8 7/8 44893455 EU1P48BN 4.0 3/8 7/8 33893465 EU1P48CN 4.0 3/8 7/8 35893469 EU1P49CN 4.0 3/8 7/8 53893456 EU1P50CN 4.0 3/8 7/8 40893447 EU1P59DN 5.0 3/8 7/8 49893466 EU1P60DN 5.0 3/8 7/8 42893457 EU1P62CN 5.0 3/8 7/8 58

    Features• Uncased• Upflow/Counterflow for application flexibility• Microban® antimicrobial additive in the drain

    pan to resist mold and mildew growth• One of the lowest water retention drain pans

    in the industry to minimize mold and mildew growth

    • Two dual drain connections on front of coil for installation flexibility of drain lines around furnace vent and utility connections

    • Orifice assembly designed for easy changing of orifice sizes and fast TXV connections

  • ARMSTRONG AIR HEAT PUMPS

    www.armstrongair.com

    – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

    www.eccosupply.ca 5-9ECCO Supply™

    Revised: June 2015 • Replaces: May 2013

    EVAPORATOR COILS (cont’d)• All piston coils are compatible with R22 or R410A• All drain pans are compatible with UV lights

    EH1P — DEDICATED HORIZONTAL APPLICATIONSFeatures• Cased• Dedicated horizontal• Microban® antimicrobial additive in the drain

    pan to resist mold and mildew growth• Drain pan has trough to fully drain condensate

    away• Insulated galvanized steel coil case with

    durable embossed finish• Top panels are removable for easy service or

    coil cleaning• Dual condensate drains on front and back

    of coil allows flexibility of placement to accommodate left or right airflow furnaces

    • Foil faced insulation for easy cleaning• Refrigerant connections on top of coil for ease

    of installation in left or right airflow furnaces

    ITEM # MODEL

    NOMINAL CAPACITY

    (TONS)

    REFRIGERANTCONNECTION

    LIQUID (") VAPOR (")WEIGHT

    (LBS)C893000 EH1P23AM 2.0 3/8 3/4 38C893000 EH1P23BM 2.0 3/8 3/4 50C893000 EH1P29AM 2.5 3/8 3/4 56C893000 EH1P29BM 2.5 3/8 3/4 45C893000 EH1P36BM 3.0 3/8 3/4 56C893000 EH1P36CM 3.0 3/8 3/4 64C893000 EH1P43BM 3.5/4.0 3/8 7/8 52C893000 EH1P43CM 3.5/4.0 3/8 7/8 56C893000 EH1P49CM 4.0 3/8 7/8 58C893000 EH1P49DM 4.0 3/8 7/8 66

    893496 EH1P62CM 5.0 3/8 7/8 63893494 EH1P62DM 5.0 3/8 7/8 63

  • ARMSTRONG AIR HEAT PUMPS

    www.armstrongair.com

    – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

    ECCO Supply™5-10 www.eccosupply.ca

    Revised: June 2015 • Replaces: May 2013

    ELECTRIC FURNACE MODULAR AIR SYSTEMEFC/EFV

    Model Number Guide

    Physical

    ledoM /egatloV esahP/zH

    rewolBrotoM

    )ph(

    rewolBrotoMsdeepS

    .xaMtcuDcitatS

    detaRdaoLspmA

    lanimoNegannoT

    thgieW).sbl(

    CB80CFE 1/06/032-802 4/1 3 02. 9.1 2-2/11 87CB21CFE 1/06/032-802 3/1 3 53. 6.2 3-2/12 58CC61CFE 1/06/032-802 4/3 3 51. 0.4 4 69CD02CFE 1/06/032-802 4/3 3 51. 3.4 5 401CB21VFE 1/06/032-802 3/1 * 04. 1.3 3-2/11 68CC61VFE 1/06/032-802 4/3 * 04. 7.5 4-2 79CD02VFE 1/06/032-802 4/3 * 04. 7.5 5-3 501

    deepselbairaV*

    ecanruFcirtcelE edoCnoisiveR

    tnatsnoC-CØ1/zH06/V032-802-A

    elbairaV-V

    wolFriAseireS

    )001x(MFC.moN-21

    htdiWtenibaC"2/171-B"12-C"2/142-D

    FE V 21 B C A - A1

    EFC/EFV

    EFC/EFV

    Application• 1-1/2 – 5 Ton Sizes• Upflow, Counterflow and Horizontal Positions

    Cabinet• Cabinet dimensions match standard furnace

    widths• Painted galvanized cabinet

    Components• EFC models feature efficient PSC motors• EFV models feature ECM variable speed motors• Field installed 5 – 20 kW Heat Strips• Factory installed Fan Relays for Non-Heat Strip

    installations

    ITEM # MODEL NOMINAL TONNAGE

    VOLTAGE/ HZ/PHASE WEIGHT (LBS)

    894624 EFC08BC 1-1/2 – 2 208-230/60/1 78894626 EFC12BC 2-1/2 – 3 208-230/60/1 85894628 EFC16CC 4 208-230/60/1 96894630 EFC20DC 5 208-230/60/1 104894631 EFV08BC-1A 1-1/2 – 2 208-230/60/1 79894632 EFV12BC 1-1/2 – 3 208-230/60/1 86894634 EFV16CC 2 – 4 208-230/60/1 97894636 EFV20DC 3 – 5 208-230/60/1 105

    Model Number Guide

  • ARMSTRONG AIR HEAT PUMPS

    www.armstrongair.com

    – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

    www.eccosupply.ca 5-11ECCO Supply™

    Revised: June 2015 • Replaces: May 2013

    ELECTRIC HEAT KITSMODEL NUMBER GUIDE

    ITEM # MODEL DESCRIPTION USED ON894600 AEHBCC05NSA-1 5 kW with Terminal Block BCS2*24, 36, 42, 48, 60894599 AEHBCC05CSA-1 5 kW with Circuit Breaker BCS2*24, 36, 42, 48, 60894601 AEHBCC07NSA-1 7.5 kW with Terminal Block BCS2*24, 36, 42, 48, 60894604 AEHBCC07CSA-1 7.5 kW with Circuit Breaker BCS2*24, 36, 42, 48, 60894602 AEHBCC10NSA-1 10 kW with Terminal Block BCS2*24, 36, 42, 48, 60894605 AEHBCC10CSA-1 10 kW with Circuit Breaker BCS2*24, 36, 42, 48, 60894603 AEHBCC15CSA-1 15 kW with Circuit Breaker BCS2*36, 42, 48, 60894611 AEHBCC20CSA-1 20 kW with Circuit Breaker BCS2*48, 60

    ITEM # MODEL DESCRIPTION USED ON894612 ECB25-2.5-P 2.5 kW with Terminal Block BCE3*18, 24, 30, 36, 42894613 ECB25-5-P 5 kW with Terminal Block BCE3*18, 24, 30, 36, 42, 48, 60894614 ECB25-5CB-P 5 kW with Circuit Breaker BCE3*18, 24, 30, 36, 42, 48, 60894615 ECB25-7-P 7.5 kW with Terminal Block BCE3*18, 24, 30, 36, 42, 48, 60894616 ECB25-7CB-P 7.5 kW with Circuit Breaker BCE3*18, 24, 30, 36, 42, 48, 60894617 ECB25-10-P 10 kW with Terminal Block BCE3*18, 24, 30, 36, 42, 48, 60894618 ECB25-10CB-P 10 kW with Circuit Breaker BCE3*18, 24, 30, 36, 42, 48, 60894619 ECB25-12.5CB-P 12.5 kW with Circuit Breaker BCE3*30, 36, 42, 48, 60894620 ECB25-15CB-P 15 kW with Circuit Breaker BCE3*36, 42, 48, 60894621 ECB25-20CB-P 20 kW with Circuit Breaker BCE3*48, 60

    Electric Heat Model Number Guide

    A EH BCC 05 N S A - 1

    Accessory Revision Code

    Electric Heat A - 208-230V/60hz/1Ph

    Applicable Product FamilyCabinet Size

    BC* - Air Handler

    Heat Size Circuit Protection

    05 - 5 kW Electric N - None

    07 - 7.5 kW Electric C - Circuit Breaker

    10 - 10 kW Electric15 - 15 kW Electric20 - 20 kW Electric

    TXV KITSITEM # MODEL DESCRIPTION PRICE

    894706 H4TXV01 Expansion Valve $156.00894707 H4TXV02 Expansion Valve 156.00894708 H4TXV03 Expansion Valve 156.00

    INDEXELECTRIC FURNACE MODULAR AIR SYSTEMEFC/EFV

    ELECTRIC HEAT KITSEVAPORATOR COILSEC1P / EM1P — UPFLOW / COUNTERFLOW APPLICATIONS AND UPFLOW / HORIZONTALAPPLICATIONSEH1P — DEDICATED HORIZONTAL APPLICATIONSEU1P — UPFLOW / COUNTERFLOW APPLICATIONS

    SPLIT SYSTEM HEAT PUMPS4SHP13LE — ENHANCED4SHP14LE — ENHANCED4SHP16LT — ENHANCED4SHP18LT — ENHANCED

    TXV KITS


Recommended