AVANCE III Cabinet
Avance III WiringUser Manual
Version
001The information in this manual may be altered without notice.
BRUKER BIOSPIN accepts no responsibility for actions takenas a result of use of this manual. BRUKER BIOSPIN acceptsno liability for any mistakes contained in the manual, leading tocoincidental damage, whether during installation or operation ofthe instrument. Unauthorized reproduction of manual contents,without written permission from the publishers, or translationinto another language, either in full or in part, is forbidden.
This manual was written by
Stephane Kreiss
© June 18, 2007: Bruker Biospin GmbH
Rheinstetten, Germany
P/N: Z31812DWG-Nr.: Z4D10273001
Contents
Contents ............................................................... 3
1 Introduction ........................................................... 51.1 Introduction ......................................................................... 51.2 Disclaimer ........................................................................... 51.3 Safety Issues ...................................................................... 51.4 Warnings and Notes ............................................................ 61.5 Contact for Additional Technical Assistance ......................... 61.6 Declaration of Conformity .................................................... 7
2 Console Configuration .......................................... 92.1 AVANCE III MicroBay .......................................................... 92.2 AVANCE III OneBay .......................................................... 102.3 AVANCE III TowBay HR ..................................................... 112.4 Avance III TwoBay Solids .................................................. 12
3 Internal Wiring ..................................................... 133.1 AVANCE III Wiring ............................................................. 13
4 Main Power Wiring ............................................... 254.1 AVANCE III MicroBay & OneBay 230V 16A ........................ 254.2 AVANCE III TwoBay 230V 16A ........................................... 264.3 AVANCE III TwoBay 230V 32A ........................................... 274.4 AVANCE III TwoBay 380V 3x16A ....................................... 284.5 AVANCE III OneBay Accesory Cabinet .............................. 29
User Manual Version 001 BRUKER BIOSPIN 3
Contents
4 BRUKER BIOSPIN User Manual Version 001
1Introduction 1
Introduction 1.1
The fundamentally superior precision and stability of fully digital signal generationand processing was introduced and established by the precedent-setting series ofAVANCE™ NMR spectrometers. With its digital advantage, the Bruker AVANCE™series set revolutionary standards for performance, long-term reliability and ease-of-use, whether for routine applications or the most demanding research.
The next-generation Avance III NMR spectrometer series features a second-gen-eration digital receiver technology (2G-DR™), a new milestone in NMR detectionfidelity. The 2G-DR provides significant benefits for the most demanding NMR ap-plications, e.g., materials science, polymer analysis, trace analysis, LC-NMR, MRimaging and structural biology, particularly for measurements with Bruker Bio-Spin's ultrasensitive CryoProbes™.
This manual provides detailed information on the AVANCE III console configura-tion and wiring.
Disclaimer 1.2
The AVANCE III consoles should only be used for their intended purpose asdescribed in this manual. Use of the unit for any purpose other than that for whichit is intended is taken only at the users own risk and invalidates any and allmanufacturer warranties.
Service or maintenance work on the consoles must be carried out by qualifiedpersonnel.
Only those persons schooled in the operation of Bruker spectrometers shouldoperate the unit.
Read this manual before operating the unit. Pay particular attention to any safetyrelated information.
Safety Issues 1.3
The spectrometer hardware is no more or less hazardous than any typical elec-tronic or pneumatic hardware and should be treated accordingly. Do not removeany of the protective panels from the various units. They are fitted to protect youand should be opened by qualified service personnel only. The main panel at therear of the console is designed to be removed using two quick release screws, butagain, this should only be done by trained personnel. Please note that, unless dis-connected, cooling fans on the rear panel will continue to run even with the panelremoved.
User Manual Version 001 BRUKER BIOSPIN 5 (31)
Introduction
Warnings and Notes 1.4
There are two types of information notices used in this manual. These noticeshighlight important information or warn the user of a potentially dangeroussituation. The following notices will have the same level of importance throughoutthis manual.
Note: Indicates important information or helpful hints
WARNING: Indicates the possibility of severe personal injury, loss of life orequipment damage if the instructions are not followed.
Contact for Additional Technical Assistance 1.5
For further technical assistance, please do not hesitate to contact your nearestBRUKER dealer or contact us directly at:
BRUKER BioSpin GMBHam SilberstreifenD-76287 RheinstettenGermany
Phone: + 49 721 5161 0FAX: + 49 721 5171 01Email: [email protected]: www.bruker-biospin.de
6 (31) BRUKER BIOSPIN User Manual Version 001
Declaration of Conformity
Declaration of Conformity 1.6
DECLARATION OF CONFORMITYThe undermentioned product
conforms to the main requirementsset by the commission for the
Harmonization of Regulations of the EU Member Stateswith regards to electromagnetic compatibility
(EMI 89/336/EWG) and safety (Low Voltage ElectricalEquipment: 72/23/EWG) regulations.
For the assessment the following norms were applied:
EMI: EN 61326:97+A1:98+A2:01+A3:03Safety: EN 61 010-1
Tested by:
Test report:
Manufacturer’s Name: Bruker Elektronik D-76287 RheinstettenBruker S.A. F-67166 WissembourgBruker AG CH-8117 Fällanden
Declaration approved by:
Dr. Tonio Gianotti Jean Yves Fraval Werner Schittenhelm Head of Development Technical Manager Direction
FS-0603-63703
NMR Spectrometer AVANCE III CabinetH03128T2
Rheinstetten: May 09, 2006
Nemko GmbH
User Manual Version 001 BRUKER BIOSPIN 7 (31)
Introduction
8 (31) BRUKER BIOSPIN User Manual Version 001
2Console Configuration 2
AVANCE III MicroBay 2.1
BSMS/2
AQS3
Eth. SWITCH
AQSIPSO
User Manual Version 001 BRUKER BIOSPIN 9 (31)
Console Configuration
AVANCE III OneBay 2.2
10
10
IPSO
AQS3
BSMS/2
BLAX300
BLAXH2H
Eth. SWITCH
10 (31) BRUKER BIOSPIN User Manual Version 001
AVANCE III TowBay HR
AVANCE III TowBay HR 2.3
BLA ...
BLA ...
BLA ...
BVT
MAS
BLA ...
BSMS/2
AQS3
IPSOEth. SWITCH
User Manual Version 001 BRUKER BIOSPIN 11 (31)
Console Configuration
Avance III TwoBay Solids 2.4
BLA...1000
BVT
MAS
BSMS/2
AQS
IPSOEth. SWITCH
P.S.
BLA...1000
P.S.
BLA...1000
P.S.
BLA...
12 (31) BRUKER BIOSPIN User Manual Version 001
3Internal Wiring 3
AVANCE III Wiring 3.1
User Manual Version 001 BRUKER BIOSPIN 13 (31)
nel
14 (3 PDr
AQS/3
A
BSMS
1)B
RU
KER
BIO
SPINU
ser Manual Version 001
POS.
Figure 3.1.Avance III M
icroBay 2 C
hannel with A
QS
Pream
p Page 1/2
123456789
1011121314151617181920212223242526272829303132333435363738394041424344454647484950
Ethe
rnet
Sw
itch
AQS
IPS
O
DR
U
RXA
D
REF
SGU
1
SGU
2
PRE
AMP
XBB
PR
EAM
P 1H
-2H
PSD
3
SLC
B/2
GAB
/2
SCB
20
ELC
B
BVT3
200
Cab
inet
Bac
kpa
MA
S
ETH
LANLAN
HZ13840 To NMR Station RS232
86002 To NMR Station Ethernet
TTY00
RS232
RS232TTY01
TTY04
86057 Z100240 To Probe Heat ATMA/
22887 to BSMS Keybord
86000
85997
85995
HZ10356 to Sample Changer
Included in HZ12223 to Magnet
Included in HZ12223 to Magnet
TTY05 HZ10019 To Sample Changer
Module Control W1304068PREAMP
HZ04054
Sample Control
Sample Changer
Helium Level
Keybord
ATMA/PICS
W1100125 to Probehead
W1100644 to Probehead
W1100117to Probehead
86001
8728387283
HZ04055
W1100864 to Probehead
HEATER
BTO
THERMOCOUPLER
PT100
87283
BSMS RCP87281
Lock Hold - Homospoil - INT A (Z0)88201 SER DATA
88201 SER DATA86868 GRAD CONTRL
W1213791 to Probehead
Z101089 to Probehead
GRAD OUT
SHIM
Channel 1Channel 2Channel 4
RA
M
AG
DI
ING
IRW
icationModif
Draw
nK
ST
18.06.07
r lyI
-No. fo
ing on
NC
E II
artawVA
Us PDr
AQS3
A
BSMS AQS3
er Manual Version 001
BR
UK
ER B
IOSPIN
15 (31)
POS.
Figure 3.2.Avance III M
icroBay 2 C
hannel with A
QS
Pream
p Page 2/2
123456789
1011121314151617181920212223242526272829303132333435363738394041424344454647484950
AQS
IPS
O
DR
U
RXA
D
REF
SGU
1
SGU
2
PSD
3
SCB
20
ELC
B
LTX
LRX
2H-T
X
GAB
/2
BLA2
BB
PRE
AMP
XBB
PR
EAM
P 1H
-2H
MA
S
SMA J2
J4 LO out SMA HZ03804J3 LO In SMA HZ03804SMA J4 LO Out
SMA J3 REF IN
SEL 2H/DEC
SMA 2H Lo J3 HZ12195SMA J3
SMA !SEL 2H AMP HZ13679
RF IN I1A SMARF IN I2A SMA
RF in BLA
RF in BLA
J7 SMA HZ14169SMB TP_F0 TP_F0
HZ03806
HZ10105HZ10105
J4 SMAHZ10105
SMA J2
LO2 J5 SMA HZ03804
SMA J2 LO IN
SMA J6 Ref.1 Ref. IN J1SMA HZ03804Ref. IN J1SMA HZ03804SMA J7 Ref.1
SMA FX IN HZ04329
Coaxipack U1
SMA J2 SGU Out
SMA J2 SGU Out
SMA 2H-TX FO IN SMA HZ03806
SMA TX_BLNK LTX BLANK SMA HZ03805
SMA 2H Out TRANSM 2H SMA HZ03806SMA 2H-REC J2 LOCK OUT SMB Z00055
TUNE IN SMB Z100054SMA J7 AUX OUTRF OUT SMB Z100054SMA RF IN j1
N XBB Transm. Z100052N OUT 1N OUT 2 N 1H Transm. Z100053
N XBB ProbeN 1H Probe
SMA 2H Probe
RF IN SMB Z100184TUNE OUT SMB Z100184SMB TUNE IN
SMB RF OUT
Z100371Z100057Z100056
To Probehead
20MHz IN SMA
SMA J3 SMA EXT CLK HZ03806
J1 84200J8 84200J9 84200
I1 84200I2 84200
SMA J7 AUX OUT
SMB EMERGENCY
HZ13617Coaxipack Z3Coaxipack Z4 SMB STATUS_IN
HZ14170 HR MAS TRIG0 TWIN BNC TRIG HZCoaxipack V1
AM
GR
DIA
NG
IRI
W
icationModif
Draw
nK
ST
18.06.07
r lyI
-No. fo
ing on
NC
E II
artawVA
nel
16 (3 PDr
AQS/3
A
BSMS
1)B
RU
KER
BIO
SPINU
ser Manual Version 001
POS.
Figure 3.3.Avance III M
icroBay 3 C
hannel with H
PP
R/2 P
age 1/2
0102030405060708091011121314151617181920212223242526272829303132333435363738394041424344454647484950
Ethe
rnet
Sw
itch
AQS
IPS
O
DR
U
RXA
D
REF
SGU
1
SGU
2
SGU
3
PSD
3
SLC
B/2
GAB
/2
SCB
20
ELC
B
BVT3
200
Cab
inet
Bac
kpa
MA
S
ETH
LANLAN
HZ13840 To NMR Station RS232
86002 To NMR Station Ethernet
TTY00
RS232
RS232TTY01
TTY04
86057 Z100240 To Probe Heat ATMA/PICS
22887 to BSMS Keybord
86000
85997
85995
HZ10356 to Sample Changer
Included in HZ10362 to Magnet
Included in HZ10362 to Magnet
TTY05 HZ10019 To Sample Changer
HZ04054
Sample Control
Sample Changer
Helium Level
Keybord
ATMA/PICS
W1100125 to Probehead
W1100644 to Probehead
W1100117to Probehead
86001
8728387283
HZ04055
W1100864 to Probehead
HEATER
BTO
THERMOCOUPLER
PT100
87283
BSMS RCP87281Lock Hold - Homospoil - INT A (Z0)
88201 SER DATA
88201 SER DATA
86868 GRAD CONTRLW1213791 to Probehead
Z14293 to Probehead
GRAD OUT
SHIM
Channel 1Channel 2
Channel 4
HZ10131 HZ10174 to HPPR/2HPPR
Channel 3 88201 SER DATA
HZ10109 HZ10110 to HPPR/2HPPR PSU
RA
M
AG
DI
ING
IRW
icationModif
Draw
nK
ST
18.06.07
r lyI
-No. fo
ing on
NC
E II
artawVA
HPPR/2QS/3
Us PDrAQS/3
A
BSMS A
er Manual Version 001
BR
UK
ER B
IOSPIN
17 (31)
POS.
Figure 3.4.Avance III M
icroBay 3 C
hannel with H
PP
R/2 P
age 2/2
0102030405060708091011121314151617181920212223242526272829303132333435363738394041424344454647484950
AQS
IPS
O
DR
U
RXA
D
REF
SGU
1
SGU
2
SGU
3
PSD
3
SCB
20
ELC
B
LTX
LRX
2H-T
X
GAB
BLA2
BB
BLAX
300
Cov
er M
odul
e
1H-2
H M
odul
e
XBB
Mod
ule
XBB
Mod
ule
SMA J2
J4 LO out SMA HZ03804J3 LO In SMA HZ03804SMA J4 LO Out
SMA J3 REF IN
SEL 2H/DECSMA 2H Lo J3 HZ12195SMA J3
SMA !SEL 2H AMP HZ13679
RF IN I1A SMARF IN I2A SMA
J7 SMA HZ14169SMB TP_F0
HZ03806
HZ10105HZ10105
J4 SMAHZ10105SMA J2
LO2 J5 SMA HZ03804
SMA J2 LO IN
SMA J6 Ref.1Ref. IN J1SMA HZ03804
Ref. IN J1SMA HZ03804SMA J7 Ref.1
SMA FX IN HZ04329
Coaxipack U1
SMA J2 SGU OutSMA J2 SGU Out
SMA 2H-TX FO IN SMA HZ03806
SMA TX_BLNK LTX BLANK SMA HZ03805
SMA 2H Out TRANSM 2H N Z12257SMA 2H-REC J2 LOCK OUT BNC Z12256
TUNE IN BNC Z12256SMA J7 AUX OUT
RF OUT BNCZ12256 SMA RF IN j1
N XBB Transm. N OUT 1N OUT 2 N 1H Transm. Z100053
N XBB ProbeN 1H ProbeN 2H Probe
Z12285Z12285Z12285
20MHz IN SMA
SMA J3 SMA EXT CLK HZ03806
J1 84200J8 84200J9 84200
I1 84200I2 84200
SMA J7 AUX OUT
SMB EMERGENCYHZ13617
Coaxipack Z3Coaxipack Z4 SMB STATUS_IN
J3 LO In SMA HZ03804SMA J4 LO Out
Ref. IN J1SMA HZ03804
SMA J8 Ref.1
SMA J2 SGU Out RF IN SMA
N OUT N XBB Transm.
Z2739Z2739Z2739
Z12285
HZ10105
AM
GR
DIA
NG
IRI
W
icationModif
Draw
nK
ST
18.06.07
r lyI
-No. fo
ing on
NC
E II
artawVA
nel
18 (3 PDr
AQS
A
BSMS
1)B
RU
KER
BIO
SPINU
ser Manual Version 001
POS.
Figure 3.5.Avance III O
neBay 3 C
hannel HR
Wiring page 1/2
0102030405060708091011121314151617181920212223242526272829303132333435363738394041424344454647484950
Ethe
rnet
Sw
itch
IPS
O
DR
U-E
RXA
D
REF
SGU
1
SGU
2
SGU
3
PSD
SLC
B/2
GAB
/2
SCB
20
ELC
B
MA
S
BVT
BLAX
H2H
...
BLAX
...
Cab
inet
Bac
kpa
HP
PR
/2
ETH
LANLAN
ETH
ETH
HZ13840 To NMR Station RS232
86002 To NMR Station Ethernet
TTY00RS232
RS232TTY01TTY04
Z14361To Probe Heat ATMA/PICS
HPPR HZ10331 HZ10174 Control
HPPR PSU HZ10109 Aux Power OutHZ10110
22887 to BSMS Keybord
86000
85997
85995
HZ10356 to Sample Changer
Included in HZ10362 to Magnet
Included in HZ10362 to Magnet
Sample Control
Sample Changer
Helium Level
TTY05 HZ10019 To Sample Changer
HZ13656 SER DATA
HZ13656 SER DATA
86868W1213791 to Probehead
F Controller 1
G ControllerHZ13656 SER DATA
G CON
GRAD OUT
F Controller 2F Controller 3
85997 RCPBSMS
8605087283
8728385997
8599785997
HZ04053HZ04055
RA
M
AG
DI
ING
IRW
icationModif
Draw
nK
ST
18.06.07
r lyI
-No. fo
ing on
NC
E II
artawVA
n-
HPPR/2
Us PDrAQS
A
er Manual Version 001BR
UK
ER B
IOSPIN
19 (31)
POS.
HZ13635
Figure 3.6.Avance III O
neBay 3 C
hannel HR
Wiring page 2/2
0102030405060708091011121314151617181920212223242526272829303132333435363738394041424344454647484950
IPS
O
DR
U-E
RXA
D
REF
SGU
1
SGU
2
SGU
3
PSD
SLC
B/2
GAB
/2
SCB
20
ELC
B
LTX
LRX
MA
S
BVT
BLAX
H2H
...
BLAX
...
Cab
inet
Bac
kpa
el Cov
er M
odul
e
1H-2
H M
odul
e
XBB
Mod
ule
X-BB
Mod
ule
J4 LO out SMA HZ03804J3 LO In SMA HZ03804SMA J4 LO Out
SMA J3 REF IN
HZ13928 CABLE RD 2P6000 MAS HR TRIG COAXIPACK
HZ13629 CABLE KOAX 1P2000 BNC - COAXIPACK BNC SEL 2H AMP
SMA 2H Lo J3 Z1740SMA J3
BNC HR TRIG
X IN SMA
H IN SMA
HZ04329
HZ04329HZ04329
J4 SMAHZ03805
SMA J2
LO2 J5 SMA HZ03804
SMA J2 LO IN
SMA J6 Ref.1 Ref. IN J1SMA HZ03804Ref. IN J1SMA HZ03804SMA J7 Ref.2
C.pk. T2/A1
C.pk. T2/C5
SMA J2 RF Out
SMA 2H-TR FO IN SMA HZ03806SMA TX_BLNK LTX BLANK SMA HZ03805
N 2H Out TRANSM 2H N SMA 2H-REC J2 LOCK OUT BNC
TUNE IN BNCSMA J7 AUX OUTRF OUT BNCSMA RF IN j1
XBB NN XOUTN HOUT 1H N
RF IN SMB Z100184 Z12285 to PH
20MHz IN SMA
J3 LO In SMA HZ03804SMA J4 LO OutRef. IN J1SMA HZ03804SMA J8 Ref.3
X IN SMAHZ04329
N XOUT
Z12256Z12256
Z12256Z2739
Z2739Z2739
19F NZ2739
N 1HN 2H
N XBB
N 19F
Z12285 to PHZ12285 to PHZ12285 to PH
SMA RO1SMA RO2
SMA RO3
RI 1 SMA HZ10105RI 2 SMA HZ10105RI 3 SMA HZ10105
SMA J2 RF OutSMA J2 RF Out
BLNKTR1BLNKTR2BLNKTR3
HZ10148 Blanking TR1-6 CableCoaxiPack A2CoaxiPack A1CoaxiPack A4
BLNK X BNCBLNK H BNC
BLNK X BNC
10MHz J2 SMA
SMA J3 HZ04329 10MHz EXTCLK SMA
TGPF0 J7 SMASMB TGPF0
Status_INEmergency Stop
SMB Status_IN
C.pk. T2/Z3
C.pk. T2/Z4SMB Emergency Stop HZ13617 CABLE COAX 1200 IPSO STATUS SIGNAL
BLNK X1 BNCBLNK H1 BNC
BLNK X2 BNC
HZ10148 CABLE KOAX 3000MM BL TR1-6 AQSBLNK TR1BLNK TR2BLNK TR3
C.pk. A1C.pk. A2
C.pk. A4
AM
GR
DIA
NG
IRI
W
icationModif
Draw
nK
ST
18.06.07
r lyI
-No. fo
ing on
NC
E II
artawVA
nel
20 (3 PDr
AQS
A
BSMS
1)B
RU
KER
BIO
SPINU
ser Manual Version 001
POS.
Figure 3.7.Avance III Tw
oBay 3 C
hannel HR
Wiring page 1/2
0102030405060708091011121314151617181920212223242526272829303132333435363738394041424344454647484950
Ethe
rnet
Sw
itch
IPS
O
DR
U-E
RXA
D
REF
SGU
1
SGU
2
SGU
3
PSD
SLC
B/2
GAB
/2
SCB
20
ELC
B
MA
S
BVT
BLAX
H2H
...
BLAX
...
Cab
inet
Bac
kpa
HP
PR
/2
ETH
LANLAN
ETH
ETH
HZ13840 To NMR Station RS232
86002 To NMR Station Ethernet
TTY00RS232
RS232TTY01TTY04
Z14361To Probe Heat ATMA/PICS
HPPR HZ10331 HZ10174 Control
HPPR PSU HZ10109 Aux Power OutHZ10110
22887 to BSMS Keybord
86000
85997
85995
HZ10356 to Sample Changer
Included in HZ10362 to Magnet
Included in HZ10362 to Magnet
Sample Control
Sample Changer
Helium Level
TTY05 HZ10019 To Sample Changer
HZ13656 SER DATA
HZ13656 SER DATA
86868W1213791 to Probehead
F Controller 1
G ControllerHZ13656 SER DATA
G CON
GRAD OUT
F Controller 2F Controller 3
85997 RCPBSMS
8605087283
8728385997
8599785997
HZ04053HZ04055
RA
M
AG
DI
ING
IRW
icationModif
Draw
nK
ST
18.06.07
r lyI
-No. fo
ing on
NC
E II
artawVA
nel HPPR/2
Us PDrA
AQS BSMS
er Manual Version 001
BR
UK
ER B
IOSPIN
21 (31)
POS.
Figure 3.8.Avance III Tw
oBay 3 C
hannel HR
Wiring page 2/2
HZ13635
0102030405060708091011121314151617181920212223242526272829303132333435363738394041424344454647484950
IPS
O
DR
U-E
RXA
D
REF
SGU
1
SGU
2
SGU
3
PSD
SLC
B/2
GAB
/2
SCB
20
ELC
B
LTX
LRX
MA
S
BVT
BLAX
H2H
...
BLAX
...
Cab
inet
Bac
kpa
Cov
er M
odul
e
1H-2
H M
odul
e
XBB
Mod
ule
X-BB
Mod
ule
J4 LO out SMA HZ03804J3 LO In SMA HZ03804SMA J4 LO Out
SMA J3 REF IN
HZ13928 CABLE RD 2P6000 MAS HR TRIG COAXIPACK
HZ13629 CABLE KOAX 1P2000 BNC - COAXIPACK BNC SEL 2H AMP
SMA 2H Lo J3 Z1740SMA J3
BNC HR TRIG
HZ04329
J4 SMAHZ03805
SMA J2
LO2 J5 SMA HZ03804
SMA J2 LO IN
SMA J6 Ref.1 Ref. IN J1SMA HZ03804Ref. IN J1SMA HZ03804SMA J7 Ref.2
C.pk. T2/A1
C.pk. T2/C5
SMA J2 RF Out
SMA 2H-TR FO IN SMA HZ03806SMA TX_BLNK LTX BLANK SMA HZ03805
N 2H Out TRANSM 2H N SMA 2H-REC J2 LOCK OUT BNC
TUNE IN BNCSMA J7 AUX OUTRF OUT BNCSMA RF IN j1
XBB NN XOUTN HOUT 1H N
RF IN SMB Z100184 Z12285 to PH
20MHz IN SMA
J3 LO In SMA HZ03804SMA J4 LO OutRef. IN J1SMA HZ03804SMA J8 Ref.3
N XOUT
Z12256Z12256
Z12256Z2739
Z2739Z2739
19F NZ2739
N 1HN 2H
N XBB
N 19F
Z12285 to PHZ12285 to PHZ12285 to PH
IN 1 SMA HZ04329
IN 2 SMA HZ04329SMA J2 RF OutSMA J2 RF Out
10MHz J2 SMA
SMA J3 HZ04329 10MHz EXTCLK SMA
TGPF0 J7 SMASMB TGPF0
Status_INEmergency Stop
SMB Status_IN
C.pk. T2/Z3
C.pk. T2/Z4SMB Emergency Stop HZ13617 CABLE COAX 1200 IPSO STATUS SIGNAL
BLNK X1 BNCBLNK H1 BNC
BLNK X2 BNC
HZ10148 CABLE KOAX 3000MM BL TR1-6 AQSBLNK TR1BLNK TR2BLNK TR3
C.pk. A1C.pk. A2
C.pk. A4
IN 1 SMA HZ04329INI 3SMA HZ04329SMA J7 Aux Out
SMA J7 Aux Out 2H FX INSMA HZ04329
AM
GR
DIA
NG
IRI
W
icationModif
Draw
nK
ST
18.06.07
r lyI
-No. fo
ing on
NC
E II
artawVA
nel
22 (3 PDrA
AQS BSMS
1)B
RU
KER
BIO
SPINU
ser Manual Version 001
POS.
Figure 3.9.Avance III Tw
oBay 3 C
hannel Solids W
iring page 2/1
0102030405060708091011121314151617181920212223242526272829303132333435363738394041424344454647484950
Ethe
rnet
Sw
itch
IPS
O
DR
U-E
RXA
D
REF
SGU
1
SGU
2
SGU
3
PSD
SLC
B/2
GAB
/2
SCB
20
ELC
B
MA
S
BVT
BLAX
100
0
BLAH
100
0
BLAX
500
Cab
inet
Bac
kpa
HP
PR
/2
ETH
LANLAN
ETH
ETH
HZ13840 To NMR Station RS232
86002 To NMR Station Ethernet
TTY00RS232
RS232TTY01TTY04
Z14361To Probe Heat ATMA/PICS
HPPR HZ10331 HZ10174 Control
HPPR PSU HZ10109 Aux Power OutHZ10110
22887 to BSMS Keybord
86000
85997
85995
HZ10356 to Sample Changer
Included in HZ10362 to Magnet
Included in HZ10362 to Magnet
Sample Control
Sample Changer
Helium Level
TTY05 HZ10019 To Sample Changer
HZ13656 SER DATA
HZ13656 SER DATA
86868W1213791 to Probehead
F Controller 1
G ControllerHZ13656 SER DATA
G CON
GRAD OUT
F Controller 2F Controller 3
85997 RCPBSMS
8605087283
8728385997
8599785997
HZ04053HZ04055
ETH85997
RA
M
AG
DI
ING
IRW
icationModif
Draw
nK
ST
18.06.07
r lyI
-No. fo
ing on
NC
E II
artawVA
nel HPPR/2
Us PDrA
AQS BSMS
er Manual Version 001
BR
UK
ER B
IOSPIN
23 (31)
POS.
Figure 3.10.Avance III TwoB
ay 3 Channel S
olids Wiring page 2/2
0102030405060708091011121314151617181920212223242526272829303132333435363738394041424344454647484950
IPS
O
DR
U-E
RXA
D
REF
SGU
1
SGU
2
SGU
3
PSD
SLC
B/2
GAB
/2
SCB
20
ELC
B
LTX
LRX
MA
S
BVT
BLAX
100
0
BLAH
100
0
BLAX
500
Cab
inet
Bac
kpa
Cov
er M
odul
e
1H-2
H M
odul
e
XBB
Mod
ule
X-BB
Mod
ule
HZ13635
J4 LO out SMA HZ03804J3 LO In SMA HZ03804SMA J4 LO Out
SMA J3 REF IN
SMA 2H Lo J3 Z1740SMA J3
BNC Solid MAS TRIG
HZ04329
J4 SMAHZ03805
SMA J2
LO2 J5 SMA HZ03804
SMA J2 LO IN
SMA J6 Ref.1 Ref. IN J1SMA HZ03804Ref. IN J1SMA HZ03804SMA J7 Ref.2
C.pk. T2/C5
SMA J2 RF Out
SMA 2H-TR TRANSM 2H N
SMA 2H-REC J2 LOCK OUT BNCTUNE IN BNCSMA J7 AUX OUTRF OUT BNCSMA RF IN j1
XBB NN XOUTN HOUT 1H N
RF IN SMB Z100184 Z12285 to PH
20MHz IN SMA
J3 LO In SMA HZ03804SMA J4 LO OutRef. IN J1SMA HZ03804SMA J8 Ref.3
N XOUT
Z12256Z12256
Z12256
Z2739
Z2739Z2739
19F NZ2739
N 1HN 2H
N XBB
N 19F
Z12285 to PHZ12285 to PHZ12285 to PH
IN 1 SMA HZ04329
IN 1 SMA HZ04329SMA J2 RF OutSMA J2 RF Out
10MHz J2 SMA
SMA J3 HZ04329 10MHz EXTCLK SMA
TGPF0 J7 SMASMB TGPF0
Status_INEmergency Stop
SMB Status_IN
C.pk. T2/Z3
C.pk. T2/Z4SMB Emergency Stop HZ13617 CABLE COAX 1200 IPSO STATUS SIGNAL
BLNK X1 BNCBLNK H1 BNC
BLNK X2 BNC
HZ10148 CABLE KOAX 3000MM BL TR1-6 AQSBLNK TR1BLNK TR2BLNK TR3
C.pk. A1C.pk. A2
C.pk. A4
IN 1 SMA HZ04329
IN 2 SMA HZ04329SMA J7 Aux OutSMA J7 Aux Out IN 2 SMA HZ04329
BNC RelayBNC Relay
C.pk. T2/C5
C.pk. T2/C5HZ10228
AM
GR
DIA
NG
IRI
W
icationModif
Draw
nK
ST
18.06.07
r lyI
-No. fo
ing on
NC
E II
artawVA
Internal Wiring
24 (31) BRUKER BIOSPIN User Manual Version 001
User Manual Version 001 BRUKER BIOSPIN 25 (31)
4Main Power Wiring 4
AVANCE III MicroBay & OneBay 230V 16A 4.1
P2
P1
6
5
DWG:
APPROV:
ART :
SHEET: /
DRAWN: VISA:
DATE:
EC :
VISA:
WS125852 A
10/05/05
***
W1213612
***
RRO0
AV-E MB 230V/16A SAFETY BOX
WIRING DIAGRAM1 1
230V/16A
BR
BL
CN M 4 TAB FLATCA:73430
16A1.5mm2
1.5mm2
BL
BR
YE/GN
YE/GN
BR
BL
ON/OFF
FILTER
BL
BR
YE
/GN
1.5mm2
SAFETY BOX
BL
BR
BR
BL
shielded5x1.5mm2
BRIDLE
BRIDLE
6600-4220
230V/10AEMB F
TO ACCESSORY RACK
SCHURTER
230VAC
W3005530
MULTISOCKETS *x 2P+E
SECU. BLOC. SUPPORTW3005524
36271
AV ON/OFF SUPPORT
36349
*X plugs
36268
36271
36266
OR
LINE INPUT CABLE
TYPE VII GIP
CN ML6/20P
C19/5795
CABLE UL
FICHE F
NORMEEUROPE
C19/5795
FICHE F
NORMEUSA
H05VVF3G1.5
SJT3X12AWG
7 METERS
7 METERS
90193
1
3
2
1 3 2
U<
J1
LINE INPUT
1
3
2
Main Power Wiring
AVANCE III TwoBay 230V 16A 4.2
P2
P1
6
5
DWG:
APPROV:
ART :
SHEET: /
DRAWN: VISA:
DATE:
EC :
VISA:
WS125910 A
09/01/06
***
W1213849
S KREISS
RRO0
AV-E 2BAY 230V/16A SAFETY BOX
WIRING DIAGRAM
1 1
6600-4220
230V/10AEMB F
TO ACCESSORY RACK
SCHURTER
W3005683
SECU. BLOC. SUPPORTW3005524
36271
AV ON/OFF SUPPORT
36349
230V/16A
BR
BL
CN M 4 TAB FLATCA:73430
16A1.5mm2
1.5mm2
BL
BR
YE/GN
YE/GN
BR
BL
ON/OFF
FILTER
BL
BR
YE
/GN
1.5mm2
SAFETY BOX
BL
BR
BR
BL
shielded5x1.5mm2
BRIDLE
BRIDLE
230VAC
2x MULTISOCKETS 6x 2P+E
6x plugs
36269
BRIDLE
BL
YE/GN
BR
36271
36266
36268
OR
LINE INPUT CABLE
TYPE VII GIP
CN ML6/20P
C19/5795
CABLE UL
FICHE F
NORMEEUROPE
C19/5795
FICHE F
NORMEUSA
H05VVF3G1.5
SJT3X12AWG
7 METERS
7 METERS
90193
1 3 2
1
3
2
U<
1
3
2
J1
LINE INPUT
26 (31) BRUKER BIOSPIN User Manual Version 001
AVANCE III TwoBay 230V 32A
User Manual Version 001 BRUKER BIOSPIN 27 (31)
AVANCE III TwoBay 230V 32A 4.3
6P2
5P1
L N
COMMENTS
VISA:APPROV:
REV
DWG : W2S125906 1/1
DATE:
MODIFIED/DATE
A
VISA:
SHEET:
RRODATE:
ART : W1213841 EC:00
AV-E 2BAY 230V/32A SAFETY BOX
WIRING DIAGRAM
NUMBER
15/12/05
DRAWN:
TO DISPATCHING 230V
3x6mm2
3x4mm2
230V/10AEMB F
TO ACCESSORY RACK
KM1 CTRL 230VAC
BR
BL
KM1
2
BRIDLE
BK
1.5mm2
BL
ON/OFF
A1A2
3
YE/GN
BL
KM1
BL
BK
BL
BK
4
230V/16A
YE
/GN
1
SAFETY BOX
BRIDLEMCB1
FUS DISJONCT S202-D32A
YE/GN
ESB40-20230VAC
LINE INPUT
RECEPT FLATS6.3 4-6MM2
shielded5x1.5mm2
Shielded
BK
6600-4220
W3005683AV ON/OFF SUPPORT
3 4
PLUG AC MALE
1 2
U<1 3 2
N N N
LUG RING M4/6
N L
N L
L CA:73430CN M 4 TAB FLAT
L
CN M 4 TAB FLATCA:73430
CN M 4 TAB FLATCA:73430
N
4mm2CN M 4 TAB FLAT
CA:73430
3X1.5mm2L CA:73430
CN M 4 TAB FLAT
CN M 4 TAB FLATCA:73430
N
6mm2
BL
BL
BL
BL
BL
BL
BL
YE/GN
YE/GN
YE/GN
YE/GN
YE/GN
YE/GN
YE/GN
YE/GN
4mm2
SHEET:
RRODATE:
AV-E 2BAY 230V/32A DISPATCHING
WIRING DIAGRAM
ART : W1213840
4mm2
EC:00
NUMBER
4mm2
4mm2
15/12/05
4m
m2
DRAWN:
COMMENTS
VISA:APPROV:
REV
DWG : WS125905 1/1
DATE:
MODIFIED/DATE
A
VISA:
BK
BL
YE/GN
CN M 4 TAB FLATCA:73430N
1.5mm2
LINEFILTER
6mm2
MCB1
YE
/GN
BLA- 1000
BLA- 1000
BLA- 1000
BL
BL
YE/GN
YE/GN
YE/GN
YE/GNFAN
BK
BL
BK
BK
BK
BK
BK
BK
BK
BL
BL
BK
BK
BK
BK
4X CABLE LINE CORD
4X CABLE LINE CORD
4X CABLE LINE CORD
BREAKER.MAGTHER
AC SOCKET
+
SCREW
Main Power Wiring
AVANCE III TwoBay 380V 3x16A 4.4
L3N L2 L1
P2
P1
6
5
COMMENTS
VISA:APPROV:
REV
DWG : WS125911 1/1
DATE:
MODIFIED/DATE
A
VISA:
SHEET:
RRODATE:
ART : W1213850 EC:
AV-E 2BAY 380V SAFETY BOX
WIRING DIAGRAM
NUMBER
12/12/05
DRAWN:
2 1
4 3
BK
BL
2.5mm2MCB1 KM1
5x2.5mm2
YE/GN
BR
BL BL
BK
YE/GN
6
8
BK 5
7
2.5mm2
RECEPTFLATS 6.32.5MM2
DSX DISPATCHING 400V
3P+T
BK
BR
BK
BK
5x2.5mm2
BK
BR
BL
ON/OFF
YE
/GN
1.5mm2
CONTACTORESB63-40-006
BR BL
6600-4220
230V/10AEMB F
KM1
SCHURTER
A2A1
BRIDLE
BRIDLE
YE/GN
shielded5x1.5mm2
W3005683AV ON/OFF SUPPORT
S204-D16
1 2
5 6
U<
1 3 2
PLUG AC MALE
3 4
7 8
N
L3N
L3
LUG RING M4/6L2 L1
L2 L1
P2N
N
P1N
L
LINE FILTER
BR
BR
BR
BR
BL
BL
BL
BL
BL
BR
YE/GN
YE/GN
YE/GN
YE/GN
YE/GN
SHEET:
RRODATE:
AV-E 2BAY 380V DISPATCHING 3X16A
WIRING DIAGRAM
ART : W1213851 EC:
NUMBER
20/12/05
DRAWN:
COMMENTS
VISA:APPROV:
REV
DWG : WS125912 1/1
DATE:
MODIFIED/DATE
A
VISA:
BR
BL
YE/GN
1.5mm2
CN M 4 TAB FLATCA:73430
1.5mm2
YE
/GN
B
C
D
E
F
G
CA:73430
CN M 4 TAB FLATCA:73430
CN M 4 TAB FLAT
BK
BR
BL
YE/GN
(BLAX1000)
N
CN M 4 TAB FLATCA:73430
CN M 4 TAB FLAT
BR
BL
YE/GN
(BLAH1000)
A
BL
BL
BR
BR
YE/GN
YE/GN
K
J
H
L
YE/GN
I
YE/GN
YE/GN
3X1.5mm2
YE/GN
BL
BR
CN M 4 TAB FLAT
BR
BL BL
BK
BL
BR
BK
BK
YE/GN
1.5mm2
CA:73430 CA:73430
380V/16A73833
1
2
3
CON 7PINS F SRT
1
2
3
4
5
6
7
SCREW
AC SOCKET
28 (31) BRUKER BIOSPIN User Manual Version 001
AVANCE III OneBay Accesory Cabinet
AVANCE III OneBay Accesory Cabinet 4.5
DWG:
APPROV:
ART :
SHEET: /
DRAWN: VISA:
DATE:
EC :
VISA:
WS125915 A
04/01/06
****
W1213858
****
RRO0
AV-E 1/MB ACCES. CAB. 16A SAFETY BOX
WIRING DIAGRAM
1 1
230V/16A
16A 1.5mm2
1.5mm2
BL
BR
YE/GN
YE/GN
BK
BL
FILTER
SAFETY BOX
BRIDLE
ACCESSORY RACK
KM1 CTRL 230VAC
MULTISOCKETS *x 2P+ESECU. BLOC. SUPPORTW300%%%
*x plugs
36266
YE
/GN
BK
HAR/UL
S202-D16A
ESB63-20-001
36275
5991
79953
230VACA2
A1
BL
3x1.5mm2
BL BL
KM1
8BK
MCB1
7
2 1
BK1.5mm2
1.5mm2
BRIDLE
OR
LINE INPUT
CABLE
TYPE VII GIP
CN M
L6/20P
C19/5795
CABLE UL
FICHE F
NORME
EUROPE
C19/5795
FICHE F
NORME
USA
H05VVF3G1.5
SJT3X12AWG
7 METERS
7 METERS
90193
6 2
J1
LINE INPUT
10 8
1 3 2
User Manual Version 001 BRUKER BIOSPIN 29 (31)
Main Power Wiring
30 (31) BRUKER BIOSPIN User Manual Version 001
User Manual Version 001 BRUKER BIOSPIN 31 (31)
Notes: