+ All Categories
Home > Technology > Beijer i x_t15br_rugged_series_brochure

Beijer i x_t15br_rugged_series_brochure

Date post: 16-Apr-2017
Category:
Upload: electromate
View: 118 times
Download: 0 times
Share this document with a friend
7
iX HMI Rugged iX HMI Rugged Proven to the extremes ELECTROMATE Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 www.electromate.com [email protected] Sold & Serviced By:
Transcript

iX HM

I Rugged

iX HMI RuggedProven to the extremes

ELECTROMATEToll Free Phone (877) SERVO98

Toll Free Fax (877) SERV099www.electromate.com

[email protected]

Sold & Serviced By:

Ruggedly reliableWhen the going gets tough, it just keeps goingOperating in extreme environments is tough stuff. So we designed the rugged iX HMI operator panel to give you a long and productive service life, no matter how rough it gets.

Flexible software and rock solid hardware always function smoothly. Whether they’re hit by wind, snow and rain, working on heavy duty motors in remote locations, or in a steamy offshore engine room. Things might get hot, but you’ll never have to sweat on your hardware letting you down.

With iX HMI Rugged you get:• Proven reliability, we test our hardware to the extremes

• Trouble-free use in the harshest of environments, fully certified

• An all-in-one solution including hardware and software

30 years of rugged reliabilityWith over thirty years of experience designing and manufacturing rugged HMI, we offer you the confidence to perform in the field.

ELECTROMATEToll Free Phone (877) SERVO98

Toll Free Fax (877) SERV099www.electromate.com

[email protected]

Sold & Serviced By:

World of rugged Rugged iX HMI panels are designed and tested to perform in environments with high levels of shock, vibration, humidity and extreme temperatures. And they’re certified by all major institutions, so you can use our panels with confidence, anywhere in the world.

Oil and gas

Outdoor applications

Big engines

Rugged marine

Water and wastewater

ELECTROMATEToll Free Phone (877) SERVO98

Toll Free Fax (877) SERV099www.electromate.com

[email protected]

Sold & Serviced By:

Rugged to the coreWe don’t compromise because you don’tWe put rugged into even the smallest details in our HMI. Then we test it. And test it. And test it again. So however tough your requirements are, you can be sure the HMI can handle them.

This truly robust HMI doesn’t compromise. It’s certified by all major classification societies, designed to perform in applications exposed to arctic cold or tropical heat, to water splashes, waves or constant vibrations.

Hazardous environments everywhere Certified for use in hazardous areas, the rugged iX HMI panel can operate in any environment, even in zones where hazardous gases and vapors are present.

UL Class I Div 2 – US hazardous location certificationATEX Zone2 – European hazardous location certificationIECEx Zone2 – International hazardous location certification

Rugged marine environments This panel meets extended classes of marine certifications not normally carried by marine HMIs, making it suitable for all onboard locations. The marine tests are passed and certifications are pending.

DNV – Det Norske Veritas ABS – American Bureau of Shipping GL – Germanischer LloydLR – Lloyd’s Register UK

FOUNDED 1862

We do our best to break every part So you know they won’t break down in the field

We perform extensive testing to ensure that the rugged iX HMI operator panels meet high environmental standards and to guarantee reliable operation in challenging environments.

Read about our test procedures and certifications here. www.beijerelectronics.com/rugged

ELECTROMATEToll Free Phone (877) SERVO98

Toll Free Fax (877) SERV099www.electromate.com

[email protected]

Sold & Serviced By:

Built for the great outdoorsThe high brightness display is easily readable even with high ambient light level such as sunlight. The wide operating temperature range means it operates in extremely hot and cold environments. Thanks to IP66 sealing, the panel withstands direct snow and rain or high pressure wash-downs, dirt, grim and dust.

High vibration environmentsTested to 4 g RMS sweep sine for vibration

Tested to 40 g 11 ms half sine for shock

Wide operating temperatures Operating -30 to +70°CStorage -40 to +85°C

-30 +70

-30 +70 Ready for washdowns IP66NEMA 4

SLC memorySLC NAND flash technology provides faster write times, longer life, wider operating tem-perature range and reduced power consump-tion. Optimal qualities for use in extreme environments.

High brightness display (optional) 1,000 cd/m2 backlight with anti-reflective films provide excellent visibility. The backlight is dim-mable to less than 1 cd/m2. So you can use the panel in high and low ambient light conditions.

SealingCertified to NEMA 4 and IP66 sealing standards. That means it’s totally dust-tight and the sealing is resistant to water jets and waves.

Isolated portsThe two serial ports are each galvanically isolated. No current can flow through the ground wire when connected to another system. This provides the highest level of safety and reliability.

12 V and 24 V powerThe input power range is 10 V to 32 V, permit-ting both a 12 V and 24 V DC power supply. The extended power range allows operation without requiring a DC to DC converter.

CiX CAN module (optional)With the optional CiX CAN module you can inter-face the panel with controllers that use CAN as their communication channel.

ELECTROMATEToll Free Phone (877) SERVO98

Toll Free Fax (877) SERV099www.electromate.com

[email protected]

Sold & Serviced By:

Smart softwareAnother reason to love our hardware

The iX HMI software empowers you with unique tools to communicate. It combines top-class vector graphics and smarter functions that provide intuitive operation on the spot, and eliminate the need for user-manuals. Not to mention the almost limitless connectivity to your other equipment through the extensive list of drivers.

The essential functions you’d expectThe iX HMI software provides you with enhanced functions, including data logging, recipes, alarms, trends, audit trail and a wide range of security features.

Advanced functions you’ll relish Based on Microsoft’s .NET Framework, iX HMI software is both open and flexible. Customize and extend functionality using C#. Create your own objects and .NET controls and use them in iX.

Full of brilliant shortcutsThe intuitive development environment speeds up engineering significantly. Features such as script actions with pre-made functionality, a component library with vector graphics and a smart property grid boost your efficiency and workflow.

Connect to what you need An extensive driver list enables communication with your PLC and other automation equipment from all major automation manufacturers.

Share information easily between users and have safe control of complex machines, even over long distances. Transfer files and control panels remotely with FTP and VNC servers.

ELECTROMATEToll Free Phone (877) SERVO98

Toll Free Fax (877) SERV099www.electromate.com

[email protected]

Sold & Serviced By:

410 mm

286

mm

76 mm

Ethernet10/100 Mbit

Power supply10–32 VDC

Serial portRS-232

USB × 22.0 High speed Ethernet

10/100/1000 Mbit

Serial portRS-422, RS-485

Technical data iX T15BR

Display Type 1280 × 800, TFT Color LCD

Size 15.4”

Lighting White LED

Brightness 450 cd/m2 or 1,000 cd/m2

Touch screen Type Analog-resistive (matte or gloss)

Interfaces Ethernet 1 × 10/100Base-T, 1 ×10/100/1000Base-T

Serial 1 × RS232, 1 × RS422/485 (isolated)

USB 3 × USB 2.0 high speed

Communication modules CiX CAN module (optional): 2 × galvanically isolated ports

Processor Type Intel® Atom (1.0 or 1.6 GHz)

Memory RAM 1 GB DDR2

Flash 4 GB

External storage media One SD card slot

Realtime clock Standard Battery-backed

Power Input voltage 12 or 24 VDC (10-32 VDC)

Consumption 28 W typical @ 24 VDC

Mechanical Type Panel-mount

Size W×H×D 410 × 286 × 83 mm

Cut-out dimensions W×H 394 × 270 mm

Mass 4.5 kg

Housing material Powder-coated aluminum

Environmental Ingress protection IP66 , NEMA 4 front panel

Temperature Operating: -30 to 70 °C; Storage: -40 to 85 °C

Vibration/shock 4g RMS / 40g 11ms half sine

Certifications UL UL/cUL 508, UL50E Type 4 Outdoor

Marine DNV*, GL*, ABS*, LR*

Hazardous UL/cUL Class I Div 2, ATEX (Zone 2), IECEx (Zone 2)

CE EN61000-6-4, EN61000-6-2

Software Development environments iX Developer

Runtime environments iX HMI software

* The marine tests are passed and certifications are pending.

ELECTROMATEToll Free Phone (877) SERVO98

Toll Free Fax (877) SERV099www.electromate.com

[email protected]

Sold & Serviced By:


Recommended