Bell housing Operating / Installation manual BMA0003
Transcript

Bell housing

Operating / Installation manual

BMA0003

Raja-Lovejoy GmbH Bell housing Number: BMA0003Friedrichstr. 6 operating / Page: 1 of 11D-58791 Werdohl installation manual Version: 1ENG

Copyright reserved Signed: 27.09.2010 MBOZ Replacement for:       

Table of contents:

1.0 General information: ........................................................................ 3

1.1 Safety and information symbols: ................................................................ 3

1.2 General hazard warnings:............................................................................ 3

2.0 Intended use: .................................................................................... 4

3.0 Dimensions: ...................................................................................... 4

Figure 1: Diagram of fixed version & integrated damped version ................. 4

Figure 2: Diagram of fixed version & multi‐part damped version .................. 4

Table 1: Motor flange dimensions ø160 ‐ ø200 ‐ part 1 ................................. 5

Table 2: Motor flange dimensions ø400 ‐ ø800 ‐ part 2 ................................. 5

Figure 3: Diagrams of bell housing for gear pumps ....................................... 6

Table 3: Motor flange dimensions ø160mm .................................................. 6

Table 4: Motor flange dimensions ø200mm .................................................. 7

Table 5: Motor flange dimensions ø250mm .................................................. 7

Table 6: Motor flange dimensions ø300mm .................................................. 8

Table 7: Motor flange dimensions ø350mm .................................................. 8

Table 8: Motor flange dimensions ø400mm .................................................. 8

4.0 Assembly .......................................................................................... 9

Figure 4: Grille ................................................................................................ 9

Figure 5: Plug .................................................................................................. 9 

 

as per ISO 16016 Checked: 01.04.2011 JZIS  Replaced by:        

Raja-Lovejoy GmbH Bell housing Number: BMA0003Friedrichstr. 6 operating / Page: 2 of 11D-58791 Werdohl installation manual Version: 1ENG

Copyright reserved Signed: 27.09.2010 MBOZ Replacement for:       as per ISO 16016 Checked: 01.04.2011 JZIS  Replaced by:        

4.1 Fitting the bell housing to the electric motor ............................................10

Figure 4: Exploded diagram: Motor / Bell housing / Pump ..........................10

Table 9: Tightening torques .........................................................................10

5.0 Additional information: .................................................................. 11

Raja-Lovejoy GmbH Bell housing Number: BMA0003Friedrichstr. 6 operating / Page: 3 of 11D-58791 Werdohl installation manual Version: 1ENG

Copyright reserved Signed: 27.09.2010 MBOZ Replacement for:       

The bell housing connects the electric motor and the hydraulic pump. Bell housings are produced in aluminium, cast iron, and steel.

1.0 General information: Carefully read through this installation manual before installing the bell housing. Pay particular attention to the safety instructions! The installation manual is part of your product. Store it carefully and in the vicinity of the bell housing. The copyright for this installation manual shall remain with Raja-Lovejoy GmbH.

1.1 Safety and information symbols:

Danger Risk of injury to personnel

Caution Damage could occur to the machine

Note Note regarding important information

1.2 General hazard warnings:

During installation and removal of the bell housing, make sure that the entire drive train is secured to prevent accidental activation, and that the system is depressurised. Rotating parts can cause serious injury. For this reason, the following safety instructions should be read and followed without exception.

• All work on the bell housing should be performed from the perspective of ->“Safety First” • Secure the drive unit to prevent unintentional activation, e.g. by attaching information signs to the switch-on points or removing the fuse at the power supply. • Do not reach into the working area of the machine while it is still in operation. • Protect the rotating parts to prevent accidental touching. Attach the relevant protective devices and covers.

as per ISO 16016 Checked: 01.04.2011 JZIS  Replaced by:        

Raja-Lovejoy GmbH Bell housing Number: BMA0003Friedrichstr. 6 operating / Page: 4 of 11D-58791 Werdohl installation manual Version: 1ENG

Copyright reserved Signed: 27.09.2010 MBOZ Replacement for:       

2.0 Intended use: You may only install and maintain the bell housing if you: • have carefully read and understood the installation manual • are authorised and trained to do so The bell housing may only be used in accordance with the technical specifications. Unauthorised structural changes to the bell housing are prohibited. We will not accept any liability for damage occurring as a result of this. In the interest further development, we reserve the right to make technical changes. The bell housings described here correspond with the latest technical standards at the time of publication of this installation manual. The bell housing is usually delivered ready for installation.

3.0 Dimensions:

Figure 1: Diagram of fixed version & integrated damped version

Figure 2: Diagram of fixed version & multi-part damped version

 

as per ISO 16016 Checked: 01.04.2011 JZIS  Replaced by:        

Raja-Lovejoy GmbH Bell housing Number: BMA0003Friedrichstr. 6 operating / Page: 5 of 11D-58791 Werdohl installation manual Version: 1ENG

Copyright reserved Signed: 27.09.2010 MBOZ Replacement for:       

Table 1: Motor flange dimensions ø160 - ø200 - part 1

Table 2: Motor flange dimensions ø400 - ø800 - part 2

 

as per ISO 16016 Checked: 01.04.2011 JZIS  Replaced by:        

Raja-Lovejoy GmbH Bell housing Number: BMA0003Friedrichstr. 6 operating / Page: 6 of 11D-58791 Werdohl installation manual Version: 1ENG

Copyright reserved Signed: 27.09.2010 MBOZ Replacement for:       

Figure 3: Diagrams of bell housing for gear pumps

 

Table 3: Motor flange dimensions ø160mm

 

as per ISO 16016 Checked: 01.04.2011 JZIS  Replaced by:        

Raja-Lovejoy GmbH Bell housing Number: BMA0003Friedrichstr. 6 operating / Page: 7 of 11D-58791 Werdohl installation manual Version: 1ENG

Copyright reserved Signed: 27.09.2010 MBOZ Replacement for:       

Table 4: Motor flange dimensions ø200mm

 

Table 5: Motor flange dimensions ø250mm

 

as per ISO 16016 Checked: 01.04.2011 JZIS  Replaced by:        

Raja-Lovejoy GmbH Bell housing Number: BMA0003Friedrichstr. 6 operating / Page: 8 of 11D-58791 Werdohl installation manual Version: 1ENG

Copyright reserved Signed: 27.09.2010 MBOZ Replacement for:       

Table 6: Motor flange dimensions ø300mm

 

Table 7: Motor flange dimensions ø350mm

 

Table 8: Motor flange dimensions ø400mm

 

as per ISO 16016 Checked: 01.04.2011 JZIS  Replaced by:        

Raja-Lovejoy GmbH Bell housing Number: BMA0003Friedrichstr. 6 operating / Page: 9 of 11D-58791 Werdohl installation manual Version: 1ENG

Copyright reserved Signed: 27.09.2010 MBOZ Replacement for:       

4.0 Assembly

  The screws should normally be secured with Loctite, Omnifit 230M or a comparable thread adhesive.

To achieve the full loading capacity of the bell housings, all fastening holes must be screwed to the electric motor.

If the bell housing in question has leakage or installation holes they should be sealed, according to instructions, to make it impossible to touch the rotating coupling. We offer grilles and plugs for this purpose.

Figure 4: Grille

Figure 5: Plug

as per ISO 16016 Checked: 01.04.2011 JZIS  Replaced by:        

Raja-Lovejoy GmbH Bell housing Number: BMA0003

Friedrichstr. 6 operating / Page: 10 of 11

D-58791 Werdohl installation manual Version: 1ENG

Copyright reserved Signed: 27.09.2010 MBOZ Replacement for:       

4.1 Fitting the bell housing to the electric motor • The bell housing is slid onto the centring device of the electric motor and the hydraulic pump, and screwed into place. Only use the existing threaded holes in the bell housing to screw it together with the electric motor. • Insert the cheese head screws (per DIN 912) into the through-holes of the electric motor flange and screw them into the threaded holes in the bell housing. Preferably, a screw length should be selected which enables the entire thread depth of the threaded holes to be used in the bell housing. • Please see Table 9 for the screw tightening torques for the electric motor. • The screw tightening torques for the hydraulic pump can be found in the technical documentation of the hydraulic pump manufacturer.

Figure 4: Exploded diagram: Motor / Bell housing / Pump

Table 9: Tightening torques

 

as per ISO 16016 Checked: 01.04.2011 JZIS  Replaced by:        

Raja-Lovejoy GmbH Bell housing Number: BMA0003

Friedrichstr. 6 operating / Page: 11 of 11

D-58791 Werdohl installation manual Version: 1ENG

Copyright reserved Signed: 27.09.2010 MBOZ Replacement for:       

5.0 Additional information: • The bell housings can be used either horizontally or vertically.

The customer is responsible for ensuring that there is a proper seal between the bell housing and the hydraulic pump. Seals for this purpose can be ordered from us.

as per ISO 16016 Checked: 01.04.2011 JZIS  Replaced by:        