Fire Alarm Systems | BZ 500 LSN Fire Panel The BZ 500 LSN is the ideal fire panel for small and medium- sized objects and offers all the benefits of modern bus technology. Modular extension options make it possible to easily adapt the fire panel to changed operating conditions. Flexible detector integration makes extending the fire alarm system simple and cost-effective. System Overview BE 500 BAT 100 LSN (230 V) Fire 1 2 3 7 8 0 9 5 6 4 BZ 500 LSN 0 400 LSN 0T 400 LSN 0C 410 LSN 0TC 410 LSN T 400 LSN MSS 400 SA MSS 400 DM 210 LSN Feuerwehr SM 210 LSN Feuerwehr 0T 300 GLT FK 100 LSN NBK 100 LSN DOW 1171 Fire 1 2 3 7 8 0 9 5 6 4 SM 20 SM 20 1 2 3 Pos. Description 1 Conventional technology 2 LSN loop 3 Radio technology BZ 500 LSN Fire Panel Easy installation due to modular configuration Up to two loop or four stub lines can be connected For max. 254 LSN elements in up to 64 detector zones and 16 control groups Separate alarm counter for fire alarms and test alarms Self-monitoring of processor technology (Watchdog) www.boschsecurity.com
Transcript
  • Fire Alarm Systems | BZ 500 LSN Fire Panel

    The BZ 500 LSN is the ideal fire panel for small and medium-sized objects and offers all the benefits of modern bustechnology.

    Modular extension options make it possible to easily adaptthe fire panel to changed operating conditions. Flexibledetector integration makes extending the fire alarm systemsimple and cost-effective.

    System Overview

    BE 500

    BAT 100 LSN

    (230 V)

    Fire Alarm

    Next TypeMessage

    FireExternal Alarm

    NextMessage

    1 2 3

    7 8

    CE

    no yesStop

    Enter

    Day/NightOn/Off

    ResetSystem

    Code

    Malfunction

    System

    Transmission unit

    Sounder/Strobe

    Power supply

    Operation

    Code operation

    Day operation

    Maintenance

    Switch off

    Transmission unit

    Sounder/Strobe

    Control

    Transmission unit

    VerificationTime

    ZoneDetector

    SwitchOff

    SounderStrobe

    Reset

    TransmissionUnit

    Control

    ExtinguishingSystem

    Maintenance

    SwitchingPoint

    Addit.Function

    Silence buzzer

    0

    9

    5 64

    BZ 500 LSN

    FireInternal Alarm

    Next TypeDetector

    Message

    Action

    ALARM ALARM

    1 3317 49

    16 4832 64

    ALARM

    65 81

    80 96

    BOSCH Security Systems

    Scheibe einschlagen

    Knopf drücken

    0 400 LSN 0T 400 LSN 0C 410 LSN 0TC 410 LSNT 400 LSN

    MSS 400 SA

    MSS 400

    DM 210 LSN

    Feuerwehr

    Scheibe einschlagen

    SM 210 LSN

    Feuerwehr

    0T 300 GLT

    FK 100 LSN NBK 100 LSN

    DOW 1171

    Fire Alarm

    Next TypeMessage

    FireExternal Alarm

    NextMessage

    1 2 3

    7 8

    CE

    no yesStop

    ALARM ALARM

    1 3332 49

    16 3348 64

    Enter

    Day/NightOn/Off

    ResetSystem

    Code

    Malfunction

    System

    Transmission unit

    Sounder/Strobe

    Power supply

    Operation

    Code operation

    Day operation

    Maintenance

    Switch off

    Transmission unit

    Sounder/Strobe

    Control

    Transmission unit

    VerificationTime

    ZoneDetector

    SwitchOff

    SounderStrobe

    Reset

    TransmissionUnit

    Control

    ExtinguishingSystem

    Maintenance

    SwitchingPoint

    Addit.Function

    Silence buzzer

    0

    9

    5 64

    FireInternal Alarm

    Next TypeDetector

    Message

    Action

    BOSCH Security Systems

    SM 20

    SM 20

    1

    2

    3

    Pos. Description

    1 Conventional technology

    2 LSN loop

    3 Radio technology

    BZ 500 LSN Fire Panel▶ Easy installation due to modular configuration▶ Up to two loop or four stub lines can be connected▶ For max. 254 LSN elements in up to 64 detector zones

    and 16 control groups

    ▶ Separate alarm counter for fire alarms and test alarms▶ Self-monitoring of processor technology (Watchdog)

    www.boschsecurity.com

  • 2 | BZ 500 LSN Fire Panel

    BZ 500 LSN modules (basic version):• ZALE 10, control unit processing module• ANNE 10, connection board• Operating and display panel• Power supply

    1

    2

    3

    4

    5

    6

    7

    8

    9

    1 0

    1 1

    1 2

    1 3

    1 4

    1 5

    1 6

    1 7

    1 8

    1 9

    2 0

    2 1

    2 2

    2 3

    2 4

    2 5

    2 6

    2 7

    2 8

    2 9

    3 0

    3 1

    3 2

    Alarm4 9

    5 0

    5 1

    5 2

    5 3

    5 4

    5 5

    5 6

    5 7

    5 8

    5 9

    6 0

    6 1

    6 2

    6 3

    6 4

    Alarm3 3

    3 4

    3 5

    3 6

    3 7

    3 8

    3 9

    4 0

    4 1

    4 2

    4 3

    4 4

    4 5

    4 6

    4 7

    4 8

    StörungSystem

    ÜESignalgeber

    Energie

    BetriebCodebetriebTagbetriebRevision

    SteuerungÜE

    AbschaltungÜE

    Signalgeber

    Feuer Alarm FeuerExternalarm Internalarm

    weitereMeldungsart Meldungweitere Melderweiterer Maßnahme

    Erkundungszeit Code Rücksetzung TagNacht

    Abschaltung Gruppe

    Rücksetzung Signalgeber

    Steuerung ÜE

    Revision Löschbereich

    Schaltpunkt

    MelderinternSummer ABC1

    DEF2

    GHI3

    STU7

    VWX8

    YZ9

    JKL4

    MNO5

    PQR6

    0 enter

    weitereFunktion

    Sirene

    nein stop jaCE

    1

    2

    3

    4

    5

    6

    7

    8

    9

    1 0

    1 1

    1 2

    1 3

    1 4

    1 5

    1 6

    1 7

    1 8

    1 9

    2 0

    2 1

    2 2

    2 3

    2 4

    2 5

    2 6

    2 7

    2 8

    2 9

    3 0

    3 1

    3 2

    Alarm4 9

    5 0

    5 1

    5 2

    5 3

    5 4

    5 5

    5 6

    5 7

    5 8

    5 9

    6 0

    6 1

    6 2

    6 3

    6 4

    Alarm3 3

    3 4

    3 5

    3 6

    3 7

    3 8

    3 9

    4 0

    4 1

    4 2

    4 3

    4 4

    4 5

    4 6

    4 7

    4 8

    Störung

    System

    Signalgeber

    Energie

    Betrieb

    Codebetrieb

    Tagbetrieb

    Revision

    Steuerung

    ÜE

    Abschaltung

    ÜE

    Signalgeber

    Feuer Alarm FeuerExternalarm MeldungFeuerInternalarm

    weitereMeldungsart Meldung

    weitereMelderweiterer Maßnahme

    Erkundungszeit Code RücksetzungAnlage

    Tag

    Nacht

    Abschaltung GruppeMelder

    Rücksetzung Signalgeber

    Steuerung ÜE

    Revision Löschbereich

    Schaltpunkt

    interner Summer ABC1

    DEF

    2GHI

    3

    STU

    7VWX

    8YZ

    9

    JKL

    4MNO

    5PQR

    6

    0 enter

    weitereFunktion

    Sirene

    Nein Stop Ja

    CE

    ANNE 10

    BZ 500 LSN

    ÜE

    1

    2

    3

    5

    6

    7

    44

    1 Front panel with operating panel and optional alarm display

    2 Toroid transformer

    3 Wall frame

    4 Battery 12 V/40 Ah

    5 Mounting location for hardware accessories

    6 Cutout for cable entry

    7 Cutout for TAE box

    Functions

    Alarm displayDisplay element is a two-line LCD display (2 x 40characters) with backlighting that is switched onautomatically when a message is received or can beswitched on manually by pressing a button.

    Operation/processing of incoming messagesBoth the operation of the entire fire alarm system and theprocessing of incoming messages is carried out on theoperating and display panel of the BZ 500 LSN.

    The fire panel is operated using membrane keys, each keypressed is acoustically confirmed.

    The BZ 500 LSN can be equipped with two key switches,each with two switch settings (optional).

    Each switch can be freely programmed, e. g..:

    • Switch 1: Switch between day/night operation• Switch 2: Connect/disconnect local alarm signaling.Recording and saving informationUp to 255 messages can be stored in an event database.

    A log printer can be connected to document messages(optional).

    Controlling the fire panelThe fire panel has integrated test software that continuallymonitors operation of the system. The test softwareperforms the following tasks running continuously in thebackground:

    • Monitoring communication between BZ 500 LSN andLSN elements

    • Monitoring the fuses• Monitoring the processor function (Watchdog)• Monitoring the program memory• Testing the RAM memory (only when starting the

    system).

    Further performance characteristics• Three interfaces can be connected (one interface is

    included in the basic version)• Two-detector dependency possible• One-man test possible• Ground connection detectionVariantsThe German design of the BZ 500 LSN is available with orwithout the alarm display.

    The BZ 500 LSN Austria has been especially configured forAustria and is a fire panel for 64 detector zones with alarmdisplay for 32 detector zones.

    The following country-specific language variants ofBZ 500 LSN are available:

    • English (en)• French (fr)• Italian (it)• Spanish (es)• Portuguese (pt)• Dutch (nl)• Danish (da)• Polish (pl)• Czech (cz)• Hungarian (hu)The alarm display is ready for installation for fire panels withforeign language labeling (cutout in housing and frontmembrane provided for the alarm display). The requiredATE 100 LSN detector zone display kit with red, yellow orred/yellow LEDs must be ordered separately.

  • BZ 500 LSN Fire Panel | 3

    Certifications and Approvals

    Region Certification

    Germany VdS-S S 295042 BS 1000

    VdS G 298002 BZ 500

    DIBt Z-6.5-1630 FSA 500 LSN Basiszulassung2007-04-13

    Z-6.5-1630 FSA 500 LSN Ergänzung2008-08-29

    Z-6.5-1630 FSA 500 LSN Ergänzung2008-12-05

    Europe CE BZ 500

    CPD 0786-CPD-20358 EV Typ BZ 500

    Austria PFB 007/BM-PSys/002 BZ 500 LSN

    007/BM-PSys/011 BZ 500 LSN

    Poland CNBOP 1908/2005 BZ 500

    CzechRepublic

    TZÚS 080_012700 BZ 500 LSN cz

    080-001277 BS 1000

    Hungary TMT TMT-50-1/2004 BZ 500 LSN

    Russia GOST POCC DE.C313.B06297

    MOE UA1.016.0107652-05 BZ 500, UEZ2000 B, UGM 2020 B

    Slovakia EVPÚ SK08-ZSV-0024 BZ 500 LSN cz

    Installation/Configuration Notes

    Basic installation/configuration notes• Country-specific standards and guidelines must be

    observed during the planning phase.• It is preferable to use the loop formation because of the

    higher security of loop lines compared with stub lines.• It is possible to combine LSN interfaces and LSN

    detectors on one loop or stub line.• Conventional detectors can be connected using an

    NBK 100 LSN fire interfaces. By connecting theNBK 100 LSN, two DC primary lines are made available.

    • When calculating the cable length for fire interfaces, theminimum required supply voltage must beremembered.

    Installation/configuration notes in accordance with VdS/VDE• Loop formation must be according to VDE 0833 if:

    - the detection area comprises more than32 detectors

    - a primary line includes multiple fire sectors.• According to VDE 0833, automatic and hold up alarm

    detectors must not be combined in a stub line.• In line with VDE 0833, a stub line must contain a

    maximum of 10 hold up alarm detectors.• Energy balancing is performed according to VDE 0833

    Part 2 and is determined using the 'UEZPRO' planningand current calculation program.

    LSN system limit values per ZALE 10• Maximum 127 LSN elements (E) per loop can be

    connected (LSN detector + LSN interface ≤ 127 E) per loop line

    • Maximum 32 LSN elements per stub line• Maximum 100 mA current consumption (higher current

    consumption disables the NVU)• Maximum cable length 1000 mVdS limit values per ZALE 10• A maximum of 512 peripheral elements (PE) can be

    connected (LSN elements + GLT elements ≤ 512 PE)• 6000 m2 maximum monitoring area• Maximum 500 m as total cable length of all detector

    alarm displays• Max. 10 hold up alarm detectors per stub (VDE 0833)Limit values for formation of loop lines or stub lines (basicversion)

    E1

    En En

    ZALE 10

    NVU 1

    I II

    E1

    E2

    En

    En-1

    I II

    E1

    ZALE 10

    NVU 1

    a b

    21

    1 Loop connection 2 Stub connection

    a 1 loop: L < 1000 m b 2 stubs: ΣL < 1000 m

    L = cable length

    Limit values for formation of loop lines or stub lines (withhardware accessories)

    E1

    En En

    ZALE 10

    NVU 1

    I II

    E1

    E2

    En

    En-1

    III IV

    E1

    ERLE 10

    NVU 2

    L 3L 2L 1

    L1 < 1000 m L2+L3 < 1000 m

    Limit values for text entry• Short text (informational text) per alarm point (address

    or sub-address dependent)- ZALE: 250 text blocks each with 19 characters- ERLE: 250 text blocks each with 19 characters

    www.boschsecurity.com

  • 4 | BZ 500 LSN Fire Panel

    • Action plan (optionally address or line statusdependent)- ZALE: 15 text blocks each with 68 (28 + 40)

    characters- ERLE: 15 text blocks each with 68 (28 + 40)

    characters• Links for activating switch points/control groups and

    alarm displays (address-, sub-address- or line status-dependent; displays flash separately for each linestatus)- 300 switch points/control groups- 16 detector points per switch point/control group- 8 line statuses per switch point/control group- 500 alarm point entries- 2000 line status entries

    Power supply• The maximum power unit current (battery charge

    current + standby current) is 12 V/5.4 A.• Two batteries with a maximum capacity of 40 Ah each

    can be charged with the integrated power pack.• If additional power is required, a UEV 1000 universal

    power supply with a 12 V/5,4 A power supply unit andtwo 40 Ah batteries can be used.

    • Alternatively, the NEV 300 looped power supply withLSN chip can be used.

    • The integrated BATES deep discharge protectiondisconnects the batteries from the loads as soon as thebattery voltage drops under 10.5 V.

    Hardware accessory optionsThe fire panel can be installed in a 19" system.

    For additional options, the UZG 1000 universal additionalhousing can be used.

    TeleService can be used in conjunction with a transmissionunit (AT 2000/MOD 300).

    Internal hardware accessories

    Module Number Short description

    ERWE 10 1 Voltage converter required for connection ofNBK 100 LSN, NTK 100 LSN, NSB 100 LSN,MSS 401. ERT 100. FK 100 LSN

    ERLE 10 1 Line extension (1 loop with L

  • BZ 500 LSN Fire Panel | 5

    For further applications like monitored activation ofsignaling devices or extinguishing systems, refer to theFLM-20 Series Interface Modules.

    Parts Included

    BZ 500 LSN Fire Panel de, en, fr, it, es, pt, nl, da, pl, cz, hu

    Qty. Components

    1 Sheet steel housing, painted light gray

    1 Operating panel with labeling in national language

    1 ANNE 10 (with a V24 interface)

    1 ZALE 10

    1 5.4 A power supply unit

    1* Front membrane for the alarm display with country-specific la-beling (without ATE 100 LSN)

    * with the exception of BZ 500 LSN de

    BZ 500 LSN Fire Panel de and at, with alarm display

    Qty. Components

    1 Sheet steel housing, painted light gray

    1 Operating panel with labeling in national language

    1 ANNE 10 (with a V24 interface)

    1 ZALE 10

    1 5.4 A power supply unit

    1 ATE 100 LSN kit with 32 red LEDs

    Technical Specifications

    Electrical

    AC line voltage 230 V AC (-15%/+10%), 50 Hz

    Current consumption

    • In standby mode 200 mA• During an alarm 270 mA• Display/illumination 200 mA• Additional per NVU 380 mA

    Power consumption 110 W (fully equipped model)

    Operating voltage 11 V DC . . . 15 V DC(13.9 V DC at 30 °C)

    Battery capacity 80 Ah (2x 12 V/40 Ah)

    Battery charge voltage 13.8V DC

    Back-up time Max. 72 h

    Mechanics

    Dimensions (W x H x D)

    • With key switch (incl. key) 443 x 501 x 230 mm• Without key switch 443 x 501 x 215 mm

    Weight (fully equipped model)

    • Without batteries 17 kg• With 2 batteries (12 V/40 Ah) 46 kg

    Color

    • Housing Light-gray, RAL 9002• Operating panel Pale gray, Bosch NCS

    Environmental conditions

    Protection class as per EN 60529 IP 40

    Classes of equipment as perEN 60950

    Class II equipment

    Permissible operating temperature -5 °C . . . +45 °C

    Permissible storage temperature -20 °C . . . +60 °C

    Planning a Local SecurityNetwork LSN

    Maximum current consumption perLSN loop

    100 mA

    Max. number of LSN elements

    • In basic model (ZALE 10) 127• With extension (ERLE 10) 254

    Maximum LSN cable length 1,000 m

    Cable for the Local SecurityNetworkLSN

    J-Y (St) Y n x 2 x 0.6 orJ-Y (St) Y n x 2 x 0.8

    Ordering Information

    BZ 500 LSN Fire Panel de, without AlarmDisplay

    BZ 500-DE

    BZ 500 LSN Fire Panel de, with AlarmDisplay for 32 Det. Zones

    BZ 500-MG-EAZ-DE

    BZ 500 LSN Fire Panel Austria, with AlarmDisplay for 32 Det. Zones

    BZ 500 A

    BZ 500 LSN Fire Panel en BZ 500-GB

    BZ 500 LSN Fire Panel fr BZ 500 FR

    BZ 500 LSN Fire Panel it BZ 500 IT

    BZ 500 LSN Fire Panel es BZ 500 ES

    BZ 500 LSN Fire Panel pt BZ 500 PT

    BZ 500 LSN Fire Panel nl BZ 500-MG-EAZ-NL

    BZ 500 LSN Fire Panel da BZ 500 DA

    BZ 500 LSN Fire Panel pl BZ 500 PL

    BZ 500 LSN Fire Panel cs BZ 500 CZ

    BZ 500 LSN Fire Panel hu BZ 500 HU

    www.boschsecurity.com

  • 6 | BZ 500 LSN Fire Panel

    Americas:Bosch Security Systems, Inc.130 Perinton ParkwayFairport, New York, 14450, USAPhone: +1 800 289 0096Fax: +1 585 223 [email protected]

    Europe, Middle East, Africa:Bosch Security Systems B.V.P.O. Box 800025600 JB Eindhoven, The NetherlandsPhone: + 31 40 2577 284Fax: +31 40 2577 [email protected]

    Asia-Pacific:Robert Bosch (SEA) Pte Ltd, Security Systems38C Jalan PemimpinSingapore 577180Phone: +65 6319 3453Fax: +65 6319 [email protected]

    Represented by

    © Bosch Security Systems Inc. 2009 | Data subject to change without noticeT275040779 | Cur: en-US, V11, 30 Mar 2009

    System OverviewFunctionsCertifications and ApprovalsInstallation/Configuration NotesParts IncludedTechnical SpecificationsOrdering Information


Recommended