- 289 - DBL_BUS_CAN_PVC.PDF Issue 22.03.2013 Klaus Faber AG, 66113 Saarbrücken, Lebacher Str. 152-156, Tel.: (0681) 9711-0, FAX: - 289 CAN-Bus-Cable (PVC) conductor material: bare copper insulation: foam-PE covering of strand: Plastic-foil screen: Cu-braid, tinned sheathing material: PVC colour of outer sheath: violet flame retardant: VDE 0482-266-2-4/IEC 60332-3-24 UV-resistant: yes oil resistant: Ja max. operating temperature, fixed: -40 - +80 °C temperature, moved/during installation: -10 - +70 °C bending radius, fixed installation: 8 x DA bending radius, moved application: 15 x DA impedance: 120 Ohm operating capacity: 40 nF/km nominal voltage U: 250 V core identification: colours acc. DIN 47100 Application: CAN-bus cable is used in the area of automation technology for the networking of controllers and control devices according to ISO 11898. The products and information presented here are for technical calculation only. They are subject to technical progress and in no way represent the ability of shipment. Outer diameters are approximately. Table: Technical characteristics CAN-Bus PVC p/n part name D A. [mm] Cu . [kg/km] G . [kg] 101120 CAN-Bus PVC 01X2X0,22 UL/CSA VL fuer feste Verlegung 6 17 38 100621 CAN-Bus PVC 02X2X0,22 UL/CSA VL fuer feste Verlegung 7,5 36 70 100961 CAN-Bus PVC 02X2X0,34 UL/CSA VL fuer feste Verlegung 8,5 46,4 88 100945 CAN-Bus PVC 01X2X0,5 UL VL fuer feste Verlegung 7,3 42 83 100574 CAN-Bus PVC 02X2X0,5 UL/ CSA VL fuer feste Verlegung 9 59,4 106 101559 CAN-Bus PVC Kombi 01X2XAWG 20 + 2X1,5 VL 62 115
Transcript
Page 1: CAN-Bus-Cable (PVC)€¦ · 100945 CAN-Bus PVC 01X2X0,5 UL VL fuer feste Verlegung 7,3 42 83 100574 CAN-Bus PVC 02X2X0,5 UL/ CSA VL fuer feste Verlegung 9 59,4 106 101559 CAN-Bus

- 289 -DBL_BUS_CAN_PVC.PDF Issue 22.03.2013 Klaus Faber AG, 66113 Saarbrücken, Lebacher Str. 152-156, Tel.: (0681) 9711-0, FAX: - 289

CAN-Bus-Cable (PVC)

conductor material: bare copper insulation: foam-PE covering of strand: Plastic-foil screen: Cu-braid, tinned sheathing material: PVC colour of outer sheath: violet flame retardant: VDE 0482-266-2-4/IEC 60332-3-24 UV-resistant: yes oil resistant: Ja max. operating temperature,fixed:

-40 - +80 °C

temperature, moved/duringinstallation:

-10 - +70 °C

bending radius, fixedinstallation:

8 x DA

bending radius, movedapplication:

15 x DA

impedance: 120 Ohm

operating capacity: 40 nF/kmnominal voltage U: 250 Vcore identification: colours acc. DIN 47100

Application: CAN-bus cable is used in the area of automation technology for the networking of controllers and controldevices according to ISO 11898.

The products and information presented here are for technical calculation only. They are subject to technical progress and in no way represent theability of shipment. Outer diameters are approximately.

Table: Technical characteristics CAN-Bus PVCp/n part name DA.

[mm]Cu.

[kg/km]G.

[kg]101120 CAN-Bus PVC 01X2X0,22

UL/CSA VL fuer festeVerlegung

6 17 38

100621 CAN-Bus PVC 02X2X0,22UL/CSA VL fuer festeVerlegung

7,5 36 70

100961 CAN-Bus PVC 02X2X0,34UL/CSA VL fuer festeVerlegung

8,5 46,4 88

100945 CAN-Bus PVC 01X2X0,5 ULVL fuer feste Verlegung 7,3 42 83

100574 CAN-Bus PVC 02X2X0,5 UL/CSA VL fuer feste Verlegung 9 59,4 106

101559 CAN-Bus PVC Kombi01X2XAWG 20 + 2X1,5 VL 62 115

Page 2: CAN-Bus-Cable (PVC)€¦ · 100945 CAN-Bus PVC 01X2X0,5 UL VL fuer feste Verlegung 7,3 42 83 100574 CAN-Bus PVC 02X2X0,5 UL/ CSA VL fuer feste Verlegung 9 59,4 106 101559 CAN-Bus

- 290 -DBL_BUS_CAN_PUR.PDF Issue 22.03.2013 Klaus Faber AG, 66113 Saarbrücken, Lebacher Str. 152-156, Tel.: (0681) 9711-0, FAX: - 289

CAN-Bus-Cable (PUR)

conductor material: bare copper insulation: foam-PE covering of strand: Plastic-foil screen: Cu-braid, tinned sheathing material: polyurethan colour of outer sheath: violet flame retardant: VDE 0482-332-1-2/IEC 60332-1 halogen free: yes UV-resistant: yes oil resistant: EN 60811-2-1 max. operating temperature,fixed:

-40 - +70 °C

temperature, moved/duringinstallation:

-30 - +70 °C

bending radius, fixedinstallation:

8 x DA

bending radius, movedapplication:

15 x DA

impedance: 120 Ohm

operating capacity: 40 nF/kmnominal voltage U: 250 Vcore identification: colours acc. DIN 47100

Application: CAN-bus cable is used in the area of automation technology for the networking of controllers and controldevices according to ISO 11898.

The products and information presented here are for technical calculation only. They are subject to technical progress and in no way represent theability of shipment. Outer diameters are approximately.

Table: Technical characteristics CAN-Bus PURp/n part name DA.

[mm]Cu.

[kg/km]G.

[kg]101121 CAN-Bus EFK PUR

01X2X0,5 UL/CSA for dragchain

8,2 42 72

100573 CAN-Bus EFK PUR02X2X0,5 UL/CSA for dragchain

10,8 59,4 106

100926 CAN-Bus EFK PUR04X1X0,25 for drag chain 9,6 41,3 58


Recommended