+ All Categories
Home > Documents > Case Study New

Case Study New

Date post: 14-Apr-2018
Category:
Upload: sakthivisalakshi
View: 218 times
Download: 0 times
Share this document with a friend

of 34

Transcript
  • 7/27/2019 Case Study New

    1/34

    INTRODUCTION Taj club house a business class hotel

    Business environment

    Comfort living environmentTo suit the needs of corporate, executives and officials

    Five star rating for the corporate kindled services.

    Located in chennai,

    In the midst of busiest

    Environment.

    Owned by GVK Group,

    Hyderabad.

    ABOUT .

    Ground area: 75 centsGround coverage area: 81,176 sq.ft

    Total number of rooms: 229 rooms

    Guest entry: 2 ways

    Vehicular entry: 2 ways

    Service entry: 1 way

    Exits: @ rear side

  • 7/27/2019 Case Study New

    2/34

    RECREATIONAL FACILITIESGYM

    SWIMMING POOL

    GYM

    2

    located in the 7th floor of the

    hotel .

    Two spaces

    equipment workout space

    manual workout space

    Along with a store room.

    1

    Glass front @ exteriorside

    Swimming pool view

    on the other side.

    LAUNDRY LINKAGE

    3

    FACILITIES

    Non slippery rubber floor.

    Wooden flooring in themanual workout area.

    High intense a/c.

    Clean movement vision.

    Waiting space.

    4

    Link to the main

    laundry space from

    gym area via laundry

    hole.

  • 7/27/2019 Case Study New

    3/34

    SWIMMING POOL21 m length

    9 m width

    1.2 m depth

    No slope even depth

    No diving allowed.

    Capacity: 1,75,000

    litres of water.

    Child pool is not specific.

    Safety precautions are given.

    Wooden platform mark the

    floor area.

    Set back8 @ the parappet

    And 6 @ swimming pool

    side.

    Pool side bar.

    Fire exit star way:Located @ the entry

    reception.

    Hose reel unit @ the

    entry space.

    Seating spaces, pool side

    allotments are provided in

    required numbers(10 15)

    number of persons.

    Access is through lift,

    stairway

    Services are done thro

    service spaces near by(20m).

  • 7/27/2019 Case Study New

    4/34

    INTERNET ROOM

    Attached with the meeting room

    Entry from open lounge

    Booked on request.No specific attention.

    8 boards in capacity.

    Interiors with woodWooden partitions

    No separate way/entry

    individualized.

    Conditioned server space

    within common to the wi-fi

    enabled meeting space.

    SMOKING SPACES

    Separate smoking area

    near the lounge in theoutdoor to facilitate

    smoking activity.

    ALL THE SPACES ARE NON

    SMOKING AREAS OTHER

    THAN

    SMOKING OUTDOOR

    FIRST FLOOR OF THE

    HOTEL

    smoking alarms are

    regulated with every 12

    and detectors in the main

    monitoring board.

  • 7/27/2019 Case Study New

    5/34

    LOBBY SPACE

    Provided with three reception units

    Travel desk

    Open type lounge

    With column segregations to attain

    A level of privacy.

    A coffee lounge

    Easy access to bar/ restaurants

    To smoking outdoors

    Fire exits and guest lifts corner

    Total area:

    Circulation movement is direct and linear

    approach.

    A small private lobby for premier guest

    with levels of secrecy are given.

  • 7/27/2019 Case Study New

    6/34

    BLEND - BAR

    A 100 seating capacity bar

    With private chambers

    Not a uniform seating arrangement.

    Central drink preparation counter

    Audio video systems

    Wooden flooring

    Carpet floor segregation

    Glass exteriors

    Outdoor party spaceLinen cushioned acoustical absorbers

    Separate wet kitchen for bar

    Wooden bottle racks clinging to wall.

  • 7/27/2019 Case Study New

    7/34

    BEHIND INDUS A MULTI CUSINE RESTAURANT.

    open to public restaurant

    small in size, about

    Seating spaces for 48 persons

    Cloak room @ the entry for

    Refreshment.Reception space and welcome

    Table is provided.

    Linked with the club house

    Restaurant.

    Separate entry for the guest @

    the building level.

    A small preparatory kitchen is provided within the

    kitchen.

    With the small Temporary store and freezer.

    A chamber of non smoke kitchen cabinet is

    provided.With waste disposal unit.( manual).

    Staff flow is through the guest way of club house

    dining a serious disadvantage.

    A level difference between the dining area.

    Immediate food service with kitchen top seating

    provisions.

  • 7/27/2019 Case Study New

    8/34

    CLUB HOUSEMajor restaurant area for the guest

    Accommodates about 130 150

    guests @ the same time.

    Dining area on a raised platform.

    Select variants on buffet display.

    Involves a display area .

    Separate juice and chat counter .

    Separate beverages counter. The kitchen is attached to

    the main kitchen and themain basement store.

    Kitchen area is 1500 sq. ft.

    and it has the cooking

    areas inclusive of it.

    Washing of utensils is

    done within the kitchen

    area.

    Ducts for exhaust are

    linked to the basementexterior

  • 7/27/2019 Case Study New

    9/34

    KEFIA Greece style restaurant

    Traffic flow adjusted between evening

    timings.

    Roof top restaurant with a bar in theexterior.

    Service lift is near the kitchen to facilitate

    easy services.

    Smoking kitchen type is found here.

    Outdoors are available

    Indoor wash unit is provided.Stucco finished walls and ceilings to match

    the morocco style.

    Interiors to suite the Greece detail.

    White bluish tint color of interiors.

  • 7/27/2019 Case Study New

    10/34

    PREMIUM BANQUET HALL

    Located in the first floor of the hotel

    With lavish interiors and an area of about

    Can be changed with the seating

    arrangements.Fully air conditioned and lit by glazing

    artificial lighting.

    Red carpet area with a reception, welcome

    drink area and food serving area.

    Along with a preparatory space.

    Provided near the fire exit and a businesstable on request @ entry.

    Directly connected to the main kitchen

    Separate dining space is provided

    Linked on close proximity to the

    elevators and stairs.

  • 7/27/2019 Case Study New

    11/34

    SUITE

    Suite are of four types

    Business class point of view

    Adhering to comfort

    Provided with common facilities

    One presidential suite on thewhole

    Comfortable interiors

    Clean , open spaces.

    Linear mode of

    Distribution.

    No cluster type

    Free flow for service

    access.Carpeted, compact

    area.

    Glazed, concealed

    openings with blind folds.

    Services made simple.Mechanized building

    systems.

    Intelligence operations

    Control over the main

    sensor display board.

  • 7/27/2019 Case Study New

    12/34

    SUPERIOR SUITE ROOM

    Provided only in the 5th floor of the

    building termed as premier suite/floor.

    Provided with a

    small pantry,work table,

    living area,

    bed space,

    Dressing room,

    Toilet,

    Bath,Jacuzzi.

    Located in the non smoking floor of the

    hotel with about 43 superior suites in

    number.

    Marble flooring along with

    carpet covers.

    Finish is of wood, carpet.

    Anti-slippery tiles @ wet spaceGlazing to the exterior side

    with blinds.

    No natural ventilation

    Lighting is achieved naturally.

    Remote sensitized operations

    in the room.

    Eyehole provisions

    Privacy through television

    chamber.

    Toilet ventilation is through

    ducts.

    No specific reception space

    within the room.Open planning.

  • 7/27/2019 Case Study New

    13/34

    SUPERIOR ROOMArea of about 345 square feet.

    Number of rooms are about 110.

    Basic executive type of room.

    Provided.

    Given with a small working table,

    A bed space,

    A seating lounge,

    Bath and closet space,

    A mini bar,

    A dress wardrobe.

    Compact, clean

    space.

    Glazing is the main

    source of light.Covered with blinds

    and wooden floor

    area @ the bed

    space.

  • 7/27/2019 Case Study New

    14/34

    DELUXE ROOMArea of about : 365

    sq.ft.

    81 rooms of this type.

    Wooden, cushionpaneling found .

    Wooden floor with a

    carpet cover.

    With a small work out

    table.

    Ironing table stand isprovided.

    c

    Rooms are placed adjacent in

    grouping of rooms.

    Common duct for two bath spaces

    are provided.A small preparatory pantry is

    provided.

    And a mini refrigerator

    A tall unit @ the entry near the toilet

    door for wardrobe.

  • 7/27/2019 Case Study New

    15/34

    DELUXE SUITE ROOM

    Each suite is of 662 sq.ft

    Same like the superior suite room

    but with an additional reception

    space.Privacy is hindered

    Open planning with no partitions in

    the dwelling space.

    Provision for physically challenged

    persons.

    A small pantry with cooking provisions

    is provided.

    Special laundry storage is provided

    Space provision for cleaning ofmattresses within the room.

  • 7/27/2019 Case Study New

    16/34

    ORGANISATION OF SPACES

    BARATHIS BUBBLE FIGURE

    IT IS WITH BARATHI..JUST REFER HER..

  • 7/27/2019 Case Study New

    17/34

    SPATIAL ORGANISATION

    Clear picture of the entire space.

    Closer proximity to the spaces.

    Open type of planning @ public areas

    with minimal degree of privacy.Visual treatment with materials and

    colors and interior elements.

    Transparency is emphasized in design.

    Maximum spatial utility is achieved in

    the design. Put a view from lobby

    From restaurant

  • 7/27/2019 Case Study New

    18/34

    CIRCULATION

    Vertical circulation is mainly thro lifts

    Guest lifts are two in number

    With a capacity of 6-8 persons of about450-625 kg.

    Located near to the banquets, meeting

    halls and common spaces in the hotel.

    With a distance of 30 m between the fire

    exit stair case and lift lobby.

    Lobby with a waiting space @ each floor.

    Corridor spaces are

    about 8 in the

    room area and

    about 10 in the

    public interactivespaces.

    Stair ways are minimally used

    For services purpose used.

    Width of the stairways is about 4.

    Provided in caution to fire safety.

  • 7/27/2019 Case Study New

    19/34

    MAIN KITCHENThere is no such common

    kitchen.

    But separate kitchens for each

    of the restaurants.But there exists a common

    store,

    Freezer, processing space for

    the

    raw materials.

    And preparatory areas in themain kitchen located on the

    ground floor.

    Various preparatory spaces

    are:

    Food and beverages

    Confectioneries

    Sea food processing units

    Meat processing unit

    Vegetable cutting unit

    Chicken processing unit

    Florist department

    Chocolate unit

    Common amenities are:

    Store for vegetables, meat,

    Chicken and sea foods.

    Processing units separate

    for veg. and non-veg.

    Freezer for the processed

    foods.

    Waste disposal unit.

    Rice boiling unit.Cutlery store.

    Kitchen office.

  • 7/27/2019 Case Study New

    20/34

    WORK PROCESS

    Dry storage

    Work table

    parcel

    Already prepared

    food

    Receiving

    food

    PREPARATORY SPACES

    Each of these spaces are rectilinear

    Partitions in plan.

    Area vary according to the usage of space.

    Glazing is provided@ the exterior

    Vents are provided to evacuate then heat.

    Each of these units

    are provided with a

    small store,

    Freezer, processing

    area apart from the

    main.

    A small work triangle is obtained in

    working.

    Efficient use of space.

    A TYPICAL PLAN

    1. COOK TOP WITH OVEN

    2. COOKING PROVISION

    3. FOOD PROCESSING

    AREA.

    4. FREEZER

    5. CLEANING AREA

    6. CUTLERY STORE

    7. TALL UNITS FOR

    STORAGE

    8. WORK TOP

    9. PULL OUT CABINETS @

    THE TOP.

  • 7/27/2019 Case Study New

    21/34

    PREPARATORY SPACE

  • 7/27/2019 Case Study New

    22/34

    MAIN KITCHEN UNIT ZONING PLAN

    PUT ZONING PLAN IF AVAILABLE ELSE GIVE SOME PICTURES

  • 7/27/2019 Case Study New

    23/34

    TAJ CLUB HOUSE KITCHEN

    provided with smoking cooking area

    non smoking kitchen

    juice cornercutlery store

    separate washing unit

    individual store

    link to main store @ the basement

    cabin for the chef to monitor

    separate freezer room for storage

    waste disposal unit

    mechanised vents

    glass partitions within

    separate processing areanear the service lifts to serve the

    banquet halls @ 1st floor

  • 7/27/2019 Case Study New

    24/34

    STAFF KITCHEN AND DINING

    Separate staff kitchen with cooking facilities

    Is provided.

    Zoned with a preparatory counter, cooking

    Area and washing area within.

    Area of about 3000 square feet inclusive of

    staff dining space for 60 people at a time.

    Hand wash area is provided within.

    No natural lighting and ventilation is felt.

    Could have provided it separately.

    Than @ the mid of boh services.

    Food serving area is very small to encourageSo many people @ same time.

    Closely associated with house keeping

    Department and staff flow area.

  • 7/27/2019 Case Study New

    25/34

    BACK OF THE HOUSE

    separate entry for the ASSOCIATE OFFICES

    services frOm the other side of the hotel

    upto single level of basement

    associate entry is to the other side of

    the building

    provided with a reception

    Provided with several departments.

    Adequate spaces are addressed.

    Not much attention to the interiors butClean, well maintained spaces.

    Circulation made transparent thro the

    Indications, not a open type of planning.

    Staff area is interrupting in between the

    Office.

  • 7/27/2019 Case Study New

    26/34

    BACK OF THE HOUSE

    GIVE A ZONING PLAN DONE IN CAD

  • 7/27/2019 Case Study New

    27/34

    BACK OF THE HOUSE

    PUT THE PICTURES OF L AND D ,

    HR,

    ACCOUNTS,

    FINANCE, STAFF,

    HOUSE KEEPING,

  • 7/27/2019 Case Study New

    28/34

    BACK OF THE HOUSE

    PUT THE PICTURES OF L AND D ,

    HR,

    ACCOUNTS,

    FINANCE, STAFF,

    HOUSE KEEPING,

  • 7/27/2019 Case Study New

    29/34

    SERVICES

    Inclusive of

    Water management systems.

    Plumbing features.

    Electrical control room.Display board room.

    Fire safety chamber.

    Laundry services.

    Parking amenities.

    Service flow(traffic).Service floor to incorporateplumbing and electrical lines is

    provided.

    Service floor is located

    between the ground and first

    floor.

    This derives the equal

    attention of supply to all the

    floors.

    And the HVAC elements are

    carried on to the top most floor.

    No proper control system over

    the board of services.

    Service floor drops down

    to 8 in height.

    Water distribution pipes

    are done thro duct spaces

    in toilets seems efficient.Electrical supply are

    remote operated and

    controlled by the main

    board.

  • 7/27/2019 Case Study New

    30/34

    WATER MANAGEMENT SYSTEMS

    Involves the storage and distribution

    of water for general use.

    Water plant room in the ground floor.

    With compressors.

    Storage tanks with processing units.

    Addition water storage tanks: 4

    Water capacity:

    Additional tanks are kept for fire safetymeasures.

    Digital monitoring of water is done to

    know about the inflow of water.

  • 7/27/2019 Case Study New

    31/34

    FIRE SAFETY MEASURES

    Fire alarms, smoke detectors are

    provided at spacing of

    every 12.

    Fire exits and hose reel provisions on

    each floor are indicative.

    Common access by service areas is

    encouraged in case of fire exits.

    PARKING @ THE HOTEL

    Parking provisions are provided around the

    building.

    No specific parking lots and numbers are

    followed.

    experience serious difficulty in case of

    banquets, meetings.

  • 7/27/2019 Case Study New

    32/34

    LAUNDRY SPACE

  • 7/27/2019 Case Study New

    33/34

    WASTE MANAGEMENT SYSTEMS

    Segregation of waste based on their components

    as

    Organic

    Inorganic

    Plastic

    Three sectors are disposed in different ways.

    Through the vehicular entry in the basement

    that is specifically for the services.

    SEWAGE DISPOSAL PLANT

    PROVIDED IN THE BASEMENT OF THE

    BUILDING.

  • 7/27/2019 Case Study New

    34/34

    MERITS

    suits to the context of business class hotel.

    circulation of spaces is made direct and according to the needs of the people.

    Transparency is achieved in the design helps in movement through the spaces.

    Business class environment in every part of the hotel.

    Lobby space is provided with lounge seating to accommodate business meetings.

    Provision of spacious lift lobby houses the waiting activity.

    Service entry being separate facilitates easy flow of services in vehicular means.


Recommended