15
AIZ 2014 MEDIUM VOLTAGE MECHANICAL CABLE LUGS & CONNECTORS CATALOGUE BOLTED ALUMINUM LUGS: ML(A), ML(B) for 1-10kV MLS(A), MLS(B) for 1-10kV ML36 for 10-36kV BOLTED ALUMINUM CONNECTORS: MC(A), MC(B) for 1-10kV MC36 for 10-36kV
Transcript
Page 1: CATALOGUE 2014 - Aiz · CABLE LUGS & CONNECTORS CATALOGUE ... Medium voltage mechanical aluminum cable lugs The main purpose of bolted lugs is to fix aluminum and copper wires to

AIZ

2014

MEDIUM VOLTAGE MECHANICAL

CABLE LUGS & CONNECTORS

CATALOGUE

BOLTED ALUMINUM LUGS: ML(A), ML(B) for 1-10kV MLS(A), MLS(B) for 1-10kV ML36 for 10-36kV

BOLTED ALUMINUM CONNECTORS: MC(A), MC(B) for 1-10kV MC36 for 10-36kV

Page 2: CATALOGUE 2014 - Aiz · CABLE LUGS & CONNECTORS CATALOGUE ... Medium voltage mechanical aluminum cable lugs The main purpose of bolted lugs is to fix aluminum and copper wires to

AAAIIIZZ

- 1 - www.aiz.lt; www.iospk.ru

Medium voltage mechanical aluminum cable lugs

BOLTED ALUMINUM LUG TYPE ML- 6...150/25...240 A for 1-10 kV

The main purpose of bolted lugs is to fix aluminum wires to electrical devices and other equipment. It doesn't need a hydraulic or mechanical tool, but a spanner to finish installation. The special eccentric design ensures enough anti-wrench strength and conductivity. The bolt has two or three share ends. The lugs and bolts are specially designed to be installed on wide range of conductors. When installing, you can choose the suitable end and tighten it until it breaks. The barrel is filled with joint compound to avoid oxidation. Share off bolts are made from aluminum alloy.

Conforms to IEC 61238-1.

M

l

L

Dd

Type L,mm l,mm d,mm D,mm MBolt q-ty

Conductor cross sec.

mm2

ML-6-25x10-A 53 19 10 16 10.5 1 6-25

ML-16-70x12-A 72 52 12 21.5 13 2 16-70

ML-70-150x12-A 90 60 17.5 27.5 13 2 70-150

ML-150-240x12-A 110 70 24.5 36 13 2 150-240

Lug Body: electrotechnical aluminum alloy, tin plated rolled threadBolts: high strength aluminum alloy

Type L,mm l,mm d,mm D,mmBolt q-ty

Conductor cross sec.

mm2

ML-6-25x10-A 53 19 10 16 1 6-25

ML-16-70x12-A 72 52 12 21.5 2 16-70

ML-70-150x12-A 90 60 17.5 27.5 2 70-150

ML-150-240x12-A 110 70 24.5 36 2 150-240

Page 3: CATALOGUE 2014 - Aiz · CABLE LUGS & CONNECTORS CATALOGUE ... Medium voltage mechanical aluminum cable lugs The main purpose of bolted lugs is to fix aluminum and copper wires to

AAAIIIZZ

www.aiz.lt; www.iospk.ru - 2 -

Medium voltage mechanical aluminum cable lugs

The main purpose of bolted lugs is to fix aluminum and copper wires to electrical devices and other equipment. It doesn't need a hydraulic or mechanical tool, but a spanner to finish installation. The special eccentric design ensures enough anti-wrench strength and conductivity. The bolt has two or three share ends. The lugs and bolts are specially designed to be installed on wide range of conductors. When installing, you can choose the suitable end and tighten it until it breaks. The barrel is filled with joint compound to avoid oxidation. Share off bolts are made from brass.

Conforms to IEC 61238-1.

M

l

L

Dd

Type L,mm l,mm d,mm D,mm MBolt q-ty

Conductor cross sec.

mm2

ML-6-25x10-B 53 19 10 16 10.5 1 6-25

ML-16-70x12-B 72 52 12 21.5 13 2 16-70

ML-70-150x12-B 90 60 17.5 27.5 13 2 70-150

ML-150-240x12-B 110 70 24.5 36 13 2 150-240

BOLTED ALUMINUM LUG TYPE ML- 6...150/25...240-B for 1-10 kV

Body material: electrotechnical aluminum alloy, tin plated rolled threadBolts: brass, tin plated

Type L,mm l,mm d,mm D,mmBolt q-ty

Conductor cross sec.

mm2

ML-6-25x10-B 53 19 10 16 1 6-25

ML-16-70x12-B 72 52 12 21.5 2 16-70

ML-70-150x12-B 90 60 17.5 27.5 2 70-150

ML-150-240x12-B 110 70 24.5 36 2 150-240

Page 4: CATALOGUE 2014 - Aiz · CABLE LUGS & CONNECTORS CATALOGUE ... Medium voltage mechanical aluminum cable lugs The main purpose of bolted lugs is to fix aluminum and copper wires to

AAAIIIZZ

- 3 - www.aiz.lt; www.iospk.ru

Medium voltage mechanical aluminum cable lugs

BOLTED ALUMINUM LUG TYPE MLS- 6...150/25...240 A for 1-10 kV

The main purpose of bolted lugs is to fix aluminum wires to electrical devices and other equipment. It doesn't need a hydraulic or mechanical tool, but a spanner to finish installation. The special eccentric design ensures enough anti-wrench strength and conductivity. The bolt has two or three share ends. The lugs and bolts are specially designed to be installed on wide range of conductors. When installing, you can choose the suitable end and tighten it until it breaks. The barrel is filled with joint compound to avoid oxidation. Share off bolts are made from aluminum alloy.

Conforms to IEC 61238-1.

Type L,mm l,mm d,mm D,mm MBolt q-ty

Conductor cross sec.

mm2

MLS-6-25x10-A 40.7 19 9.2 16 10.5 1 6-25

MLS-25-50x12-A 48.5 28 12 19 10.5 1 25-50

MLS-70-120x12-A 64.5 41 18 27 13 2 70-120

MLS-150-240x16-A 82.5 53 26 37 17 2 150-240

M

l

L

Dd

Lug Body: electrotechnical aluminum alloy, tin plated rolled threadBolts: high strength aluminum alloy

Type L,mm l,mm d,mm D,mmBolt q-ty

Conductor cross sec.

mm2

MLS-6-25x10-A 40.7 19 9.2 16 1 6-25

MLS-25-50x12-A 48.5 28 12 19 1 25-50

MLS-70-120x12-A 64.5 41 18 27 2 70-120

MLS-150-240x16-A 82.5 53 26 37 2 150-240

Page 5: CATALOGUE 2014 - Aiz · CABLE LUGS & CONNECTORS CATALOGUE ... Medium voltage mechanical aluminum cable lugs The main purpose of bolted lugs is to fix aluminum and copper wires to

AAAIIIZZ

www.aiz.lt; www.iospk.ru - 4 -

Medium voltage mechanical aluminum cable lugs

The main purpose of bolted lugs is to fix aluminum and copper wires to electrical devices and other equipment. It doesn't need a hydraulic or mechanical tool, but a spanner to finish installation. The special eccentric design ensures enough anti-wrench strength and conductivity. The bolt has two or three share ends. The lugs and bolts are specially designed to be installed on wide range of conductors. When installing, you can choose the suitable end and tighten it until it breaks. The barrel is filled with joint compound to avoid oxidation. Share off bolts are made from brass.

Conforms to IEC 61238-1.

BOLTED ALUMINUM LUG TYPE MLS- 6...150/25...240-B for 1-10 kV

Type L,mm l,mm d,mm D,mm MBolt q-ty

Conductor cross sec.

mm2

MLS-6-25x10-B 40.7 19 9.2 16 10.5 1 6-25

MLS-25-50x12-B 48.5 28 12 19 10.5 1 25-50

MLS-70-120x12-B 64.5 41 18 27 13 2 70-120

MLS-150-240x16-B 82.5 53 26 37 17 2 150-240

M

l

L

Dd

Body material: electrotechnical aluminum alloy, tin plated rolled threadBolts: brass, tin plated

Type L,mm l,mm d,mm D,mmBolt q-ty

Conductor cross sec.

mm2

MLS-6-25x10-B 40.7 19 9.2 16 1 6-25

MLS-25-50x12-B 48.5 28 12 19 1 25-50

MLS-70-120x12-B 64.5 41 18 27 2 70-120

MLS-150-240x16-B 82.5 53 26 37 2 150-240

Page 6: CATALOGUE 2014 - Aiz · CABLE LUGS & CONNECTORS CATALOGUE ... Medium voltage mechanical aluminum cable lugs The main purpose of bolted lugs is to fix aluminum and copper wires to

AAAIIIZZ

- 5 - www.aiz.lt; www.iospk.ru

Medium voltage mechanical aluminum cable lugs

BOLTED ALUMINUM LUG TYPE ML36- 16...185/95...400 for 10-36 kV

The main purpose of bolted lugs is to fix aluminum and copper wires to electrical devices and other equipment. It doesn't need a hydraulic or mechanical tool, but a spanner to finish installation. The special design ensures enough anti-wrench strength and conductivity. The bolt has two or three share ends. The lugs and bolts are specially designed to be installed on wide range of conductors. When installing, you can choose the suitable end and tighten it until it breaks. The barrel is filled with joint compound to avoid oxidation. Share off bolts are made from brass.

Conforms to IEC 61238-1.

M

l

L

D d

Body material: electrotechnical aluminum alloy, tin plated rolled threadBolts: brass, tin plated

Type L,mm l,mm d,mm D,mmBolt q-ty

Conductor cross sec.

mm2

ML36-16-95x12 60 32 12.5 24 1 16-95

ML36-50-150x12 79 35 15.5 30 1 50-150

ML36-50-150x16 79 35 15.5 30 1 50-150

ML36-95-240x12 95 56 20.0 33 2 95-240

ML36-95-240X16 95 56 20.0 33 2 95-240

ML36-120-300x12 100 67 25.0 38 2 120-300

ML36-120-300X16 100 67 25.0 38 2 120-300

ML36-185-400x12 115 82 26.0 42 3 185-400

ML36-185-400x16 115 82 26.0 42 3 185-400

Page 7: CATALOGUE 2014 - Aiz · CABLE LUGS & CONNECTORS CATALOGUE ... Medium voltage mechanical aluminum cable lugs The main purpose of bolted lugs is to fix aluminum and copper wires to

AAAIIIZZ

www.aiz.lt; www.iospk.ru - 6 -

Medium voltage mechanical cable connector

The main purpose of bolted connector is to connect aluminum wires. It doesn't need a hydraulic or mechanical tool, but a spanner to finish the installation. Special eccentric design ensures enough anti-wrench strength and conductivity. The bolt has two or three share ends. The connectors and bolts are specially designed to be installed on wide range of conductors. When installing, you can choose the suitable end and tighten it until it breaks. The barrel is filled with joint compound to avoid oxidation. Share off bolts are made from aluminum alloy.

Conforms to IEC 61238-1.

BOLTED ALUMINUM CONNECTOR TYPE MC- 6...120/25...240-A for 1-10 kV

Type L,mm d,mm D,mm MBolt q-ty

Conductor cross sec.

mm2

MC-6-25-A 40 9.3 16 8 2 6-25

MC-25-70-A 55 14.0 25 12 2 25-70

MC-70-150-A 70 17.5 28 16 2 70-150

MC-120-240-A 80 24.5 36 18 2 120-240

• Body material: electrotechnical aluminum• Bolts: High strength aluminum alloy

Type L,mm d,mm D,mmBolt q-ty

Conductor cross sec.

mm2

MC-6-25-A 40 9.3 16 2 6-25

MC-25-70-A 55 14.0 25 2 25-70

MC-70-150-A 70 17.5 28 2 70-150

MC-120-240-A 80 24.5 36 2 120-240

Page 8: CATALOGUE 2014 - Aiz · CABLE LUGS & CONNECTORS CATALOGUE ... Medium voltage mechanical aluminum cable lugs The main purpose of bolted lugs is to fix aluminum and copper wires to

AAAIIIZZ

- 7 - www.aiz.lt; www.iospk.ru

Medium voltage mechanical cable connector

BOLTED ALUMINUM CONNECTOR TYPE MC- 6...120/25...240 B for 1-10 kV

The main purpose of bolted connector is to connect aluminum and copper wires. It doesn't need a hydraulic or mechanical tool, but a spanner to finish the installation. Special eccentric design ensures enough anti-wrench strength and conductivity. The bolt has two or three share ends. The connectors and bolts are specially designed to be installed on wide range of conductors. When installing, you can choose the suitable end and tighten it until it breaks. The barrel is filled with joint compound to avoid oxidation. Share off bolts are made from brass.

Conforms to IEC 61238-1.

Type L,mm d,mm D,mm MBolt q-ty

Conductor cross sec.

mm2

MC-6-25-B 40 9.3 16 8 2 6-25

MC-25-70-B 55 14.0 25 12 2 25-70

MC-70-150-B 70 17.5 28 16 2 70-150

MC-120-240-B 80 24.5 36 18 2 120-240

• Body material: electrotechnical aluminum• Bolts material: brass, tin plated

Type L,mm d,mm D,mmBolt q-ty

Conductor cross sec.

mm2

MC-6-25-B 40 9.3 16 2 6-25

MC-25-70-B 55 14.0 25 2 25-70

MC-70-150-B 70 17.5 28 2 70-150

MC-120-240-B 80 24.5 36 2 120-240

Page 9: CATALOGUE 2014 - Aiz · CABLE LUGS & CONNECTORS CATALOGUE ... Medium voltage mechanical aluminum cable lugs The main purpose of bolted lugs is to fix aluminum and copper wires to

AAAIIIZZ

www.aiz.lt; www.iospk.ru - 8 -

Medium voltage mechanical cable connector

The main purpose of bolted connector is to connect aluminum and copper wires. It doesn't need a hydraulic or mechanical tool, but a spanner to finish the installation. Special design ensures enough anti-wrench strength and conductivity. The bolt has two or three share ends. The connectors and bolts are specially designed to be installed on wide range of conductors. When installing, you can choose the suitable end and tighten it until it breaks. The barrel is filled with joint compound to avoid oxidation. Share off bolts are made from brass

Conforms to IEC 61238-1.

BOLTED ALUMINUM CONNECTOR TYPE MC36- 16...185/95...400 for 10-36 kV

l

L

D d

82 33

• Body material: electrotechnical aluminum• Bolts material: brass, tin plated

Type L,mm l,mm d,mm D,mmBolt q-ty

Conductor cross sec.

mm2

MC36-16-95 70 32 12.5 24 2 16-95

MC36-50-150 85 35 15.5 30 2 50-150

MC36-95-240 120 56 20.0 30 4 95-240

MC36-120-300 142 67 25.0 33 4 120-300

MC36-185-400 170 82 26.0 33 6 185-400

Page 10: CATALOGUE 2014 - Aiz · CABLE LUGS & CONNECTORS CATALOGUE ... Medium voltage mechanical aluminum cable lugs The main purpose of bolted lugs is to fix aluminum and copper wires to

AAAIIIZZ

- 9 - www.aiz.lt; www.iospk.ru

Electrical installer memo

Flexible screw connecting products1.Aluminum alloy terminals2.Aluminum alloy connectors without partition3.Aluminum alloy connectors with partition4.Aluminum alloy clamps5.Bimetallic clamps

Other products6. Copper alloy clamps7. Copper alloy flat screw terminals8. Electro technical outputs – clamps; one of them are connected to the flat ones, other – to the stud (electric apparatus, machines, devices) outputs.9. Plate electro technical washers – to overcome aluminum creep.10. Bimetallic contact washers – are not resilient, designed to improve the status of contacts.11. Flat screw connection resilient contact Al – washers – to prevent aluminum creep.12. Contact grease13. Flat contact connection screw electro technical contact parts and products.14. Wedge OL resilient contact products, other products.

Notes:1. A need to overcome aluminum contact disadvantages resulted emergence of aluminum alloy screw contact production. Every product is suitable for a few adjacent conductors crocs sections; generally the same for both aluminum or copper conductor for connection according to the manufacturer's instructions.2. Casted aluminum alloy screw contact products are plated or alloy composition (Mg / Si components) is resistant to surface corrosion. However, connecting them to copper and alloys conductors in the open devices usually requires the use of corrosion prevention measures.3. Contact surfaces of cast production are striated.4. The inner cylindrical part of casted production is usually covered with contact grease.5. Product bolt tightening procedure and the torque if necessary is specified by the manufacturer.6. Some of the screw contact products can be dismantled and re-assembled.7. Conductor (cable core) centring parts may be added to the product.8. Usually there an opportunity to choose terminals with different connecting screw holes.9. Selecting the elastic contact products is necessary to evaluate the products for their intended use (compliance merging conductor design, their content, connection to electrical outputs conditions etc.)10. Elastic contact production installation is simple. Contact resistivity is low and stable.

Flat bolt connections contact details, accessories, installation tools and actions1. Electro technical screw parts, galvanized - specially produced and used in accordance to standards (e.g., DIN, GOST, CENELEK; further - Standards) requirements: Bolts; Nuts, counter nuts; Simple washers; Special increased dimension washers; Spring washers-holding the bolt from turning itself.

2. Nonferrous metal alloys electro technical screw parts - are specially manufactured and used in accordance with standards: Bolts; Nuts, counter nuts; Special increased dimension washers;

3. Electro technical measures that improve contacts - are specially manufactured and used in accordance with standards:3.1. Electro technical steel tray washers;3.2. Bimetallic washers;3.2. Al - contact elastic washers;3.3. Contact grease 3.4. Transition parts ( e.g. Flat: copper, bimetallic – copper and aluminum welded to each other and aluminum casting – with the contact holes or on-site drilling them on demand.

Page 11: CATALOGUE 2014 - Aiz · CABLE LUGS & CONNECTORS CATALOGUE ... Medium voltage mechanical aluminum cable lugs The main purpose of bolted lugs is to fix aluminum and copper wires to

AAAIIIZZ

www.aiz.lt; www.iospk.ru - 10 -

Electrical installer memo

4. Installation measures: Cloths (zero-fuzz or fibers woven cloth, cotton rags) Solvents (unleaded clean gasoline, white spirit and other fat solvents) Steel brush; Sandpaper; Depth gauge; Woven terry set of keys; Torsion set of keys; Dynamometer wrenches; Flat paintbrush; Connectors holder; Other measures;

5. Installation actions5.1 Special task of direct supervisor for electrician is required, including installation drawings (worksheet).5.2 Electrician must have conditions to complete a task.5.3 Installation steps require technological discipline.5.4 Compulsory technological job control.5.5 Acceptance of completed work is mandatory.

Conductor terminals bolting to flat indoor electrical equipment findingsConductor terminals must be connected to electrical equipment as it is shown in the instruction by the manufacturer of findings; Recommended to apply the following methodic in that case if there are no special directions from the manufacturer, it is recommended to apply the following1.There's no aluminum conductor in contact conjunction.(Can be present: copper, bronze, brassy, aluminum and steel alloy)

Preparing:Hole of the terminal conjunction plane for the bolt must match with the hole of conjunction finding. Diameter of the bolt can be smaller than the diameter of the contact output or tip contact plane just by 1 typical diameter. (E.g.: When diameter of the output hole is 13mm, tip – 11mm, M10 bolt must be used.)Hole for the bolt in terminals contact plane can not be increased;Contact conjunction bolting parts (bolts, nuts, washers, can be sparingly washer until M8) are electro technical.To prevent oxidation of aluminum alloy and other metals, except copper, contact grease must be used.

Notes:1.If conductors' wires were not suitably composed until the terminals installation, these actions must be done before connecting terminals. Assessing condition of the phase, cable termination wires have to be folded that way, that their bending curves, rapprochements and other things would meet the coupling manufacturer requirements.2.Cable below the coupling must be tightened respectively, and the grounding conductor connected to ground circuit.

Installation:Contact surfaces are degreaser with organic solvent (cloth, petrol, white spirit);Contact surfaces are cleaned to metallic gloss (coarsely sandpaper, wire brush, scraper);The contact surfaces are covered with 1-2mm of contact grease (except, when copper is connected with copper ones);Measures must be applied to prevent self-slew of the contact nut. For that purpose you must use counter nut.Counter nut is tightened. When it is done, at the bottom of the nut must be left 2-3 free thread strands.

Other notes: 1. During connection of again dismantled screw terminals, the whole assembly must be repeated. 2. Two-wire lugs (permissible only in exceptional cases and only in phase circuits), the flat output single screw plug on both sides of the outlet. 3. Contact grease lubrication of threads and mechanisms is inappropriate.4. The nominal contact compression is achieved by using a torque wrench.

a- terminal connected with M8 bolt parts, b- terminal connected with M10 and bigger diameter bolt parts, c- two conductor terminals (in exceptional cases, only in phase chain) to flat output with one bolt connected from both sides1 - core; 2 - copper terminal; 3 - output; 4 - steel contact; 5 - steel bolt; 6 - steel washer; 7 - enlarged washer; 8 - spring nut.

a) b) c)

Page 12: CATALOGUE 2014 - Aiz · CABLE LUGS & CONNECTORS CATALOGUE ... Medium voltage mechanical aluminum cable lugs The main purpose of bolted lugs is to fix aluminum and copper wires to

AAAIIIZZ

- 11 - www.aiz.lt; www.iospk.ru

Electrical installer memo

2.There are one or more aluminum conductors in the contact connection

Preparing:Hole of the terminals conjunction plane for the bolt must match with the hole of conjunction finding. Diameter of the bolt can be smaller than the diameter of the contact output or terminals contact plane just by 1 typical diameter. (E.g.: When diameter of the output hole is 13mm, tip – 11mm, M10 bolt must be used.)Hole for the bolt at contact output or terminals contact plane can not be increased;Contact conjunction bolting parts (bolts, nuts, washers, can be sparingly washer until M8) are electro technical.To avoid aluminum creep problem it is necessary to use one of these special contact compression stabilizer: tray electrical steel washers; non ferrous alloys contact bolt parts and washer or elastic contact washers. Aluminum or aluminum alloys and other metal contact surface against oxidation require the use of a contact lubricant.

Notes:1.If conductors wires were not suitably composed until the terminals installation, these actions must be done before connecting tips. Assessing condition of the phase, cable termination wires have to be folded that way, that their bending curves, rapprochements and other things would meet the coupling manufacturer requirements.2.Cable below the coupling must be tightened respectively, and the grounding conductor connected to ground circuit.Installation:Contact surfaces are degreased with organic solvent (cloth, petrol, white spirit);Contact surfaces are cleaned to metallic gloss (coarsely sandpaper, wire brush, scraper);The contact surfaces are covered with 1-2mm of contact grease (except, when copper is connected with copper ones);Depending on the contact compression stabilizers and their manufacturer instructions for installation of the measures in contact details combined and normal contact compression to achieve is usually tightened nuts such contact (M) circular moments (Nm).Using Pfisterer elastic contact washers – using the torques specified in the instruction. M8 (22), M10 (40), M16(120).When using an electrical disc steel washers or non-ferrous washers bolt parts – M5 ( 7,5 ± 1,0); M6 (10,5 ± 1,0); M8 (22,0 ± 1,5); M10 (30-44); M12(50-70); M16(60-100); M20(120-150).When the nut is tightened. When it is done, at the bottom of the nut must be left 2-3 free thread strands. In the case of elastic contact part (e.g. tray washer, elastic washer for contact), IT is not required to use counter nut.

Other notes:1.During dismantling and re-installing of screw connection of all the necessary steps have to be repeated.2.Two-wire lugs (permissible only in exceptional cases and only phase circuits), the flat output single screw plug on both sides of the outlet.3.Contact grease for lubrication of threads and mechanisms is inappropriate.4.Elastic contact washer can be re-dismantled up to 5 times.5.The normal contact compression is achieved by using a torque wrench.

BRIEFLY

Some of the common wire assembly solutions1.In any case, contact conductors shall be: mounted using appropriate electrical equipment and other tools; cleaned (dirt, grease, oxides); specially grained and coarse (free from oxide) surfaces; lubricated with contact grease, except when connecting with each other only copper surfaces; contact compression screw diameter must comply with the contacting surfaces or holes can be reduced only through a

standard diameter; protected, from the aluminum creep; necessary to compress - as indicated by the manufacturer of outlet; it is tightened bolt diameter torque size and use the self-contact nuts twirl measures; protected against the harmful effects of mechanical installation time; protected against vibration, mechanical loading of unauthorized operation.2. It is recommended to avoid the use of aluminum conductors pressed aluminum parts.3. If the connection contains at least one aluminum, part, additionally has to be used: creep reducing special bolting parts kits of your choice: disc and washers to increase the dimensions of the contact steel washers; non-ferrous metal alloy electro technical details of the bolt; Al - elastic contact and increased dimensions of the contact steel washers; special contact lubricants; in open plants and in wet areas - galvanic corrosion prevention measures. For example, aluminum conductors

(components) direct contacts not to bundle with other metal conductors (copper, brass, stainless steel), or, where appropriate, use of bi-metal parts, Al - elastic contact for the washers, or other in project (indicated) measures.

Page 13: CATALOGUE 2014 - Aiz · CABLE LUGS & CONNECTORS CATALOGUE ... Medium voltage mechanical aluminum cable lugs The main purpose of bolted lugs is to fix aluminum and copper wires to

AAAIIIZZ

www.aiz.lt; www.iospk.ru - 12 -

Electrical installer memo

M

l

L

D d

Steps of installation:1.Put and press core centering ring into barrel.2.The connector is pre-greased. Do not remove the grease.3.Strip insulation to fit conductor into barrel.4.Clean and brush conductor and put into barrel. 5.Fasten bolts steadily by hand.6.Fasten bolts slowly with tool according to pictures shown until heads shear off.7.Repeat with second side of connector.8.Screws have to be prerounded if they do not shear off flush with connector body.

Designationcross-section

ML 36216-95mm

ML 36250-150mm

ML 36295-240mm

ML 362120-300mm

ML 362185-400mm

Allen keysize

screw/unscrew

13 mmAF 6

17 mmAF 6

18 mmAF 6

22 mmAF 6

22 mmAF 6

Centring sleeve 1 clr. none 1 clr. 2 clr. none 1 clr. 2 clr. none 1 clr. none 1 clr. none

Round solidAlCu

RE: 10-50 70-90 50 70-95 120-150 95 120-150 185-240 120-185 240-300 185-240 300-400

Sector solidAlCu

SE: 16-50 70-95 50 70-95 120-150 95 120-150 185-240 120-185 240-300 185-245 300-400

Round strandedAlCu

RM:16-5010-50

70-9050

35-5070-95 95-150 95 120-150 185-240 120-185 240-300 185-240 300-400

Round stranded and compressed

AlCu

RMV: 16-50 70-95 35-50 70-95 120-150 95-120 150 185-240 120-185 240-300 185-240 300-400

Sector strandedAlCu

SM: 25-35 50-90 50 50-70 95-150 95 95-120 150-240 120-150 185-240 185 240-300Designation

cross-section

Bolt size,

Allen key size

Centring

sleeveBlue none Yellow Gray none Red Brown none Gray none Gray none

Round

solid

Al

Cu RE: 10-50 70-90 50 70-95 120-150 95 120-150 185-240 120-185240-300 185-240 300-400

Sector

solid

Al

CuSE: 16-50 70-95 50 70-95 120-150 95 120-150 185-240 120-185240-300 185-245 300-400

Round

stranded

Al

Cu RM:16-50

10-5070-90

50

35-5070-95 95-150 95 120-150 185-240 120-185240-300 185-240 300-400

Round

Stranded

and

compressed

Al

CuRMV: 16-50 70-95 35-50 70-95 120-150 95-120 150 185-240 120-185240-300 185-240 300-400

Sector

stranded

Al

CuSM: 25-35 50-90 50 50-70 95-150 95 95-120 150-240 120-150185-240 185 240-300

ML36/MC36

95-240 mm²

18 mm

AF 6

22 mm

AF 6

ML36/MC36

185-400 mm²

13 mm

AF 6

ML36/MC36

16-95mm²

17 mm

AF 6

ML36/MC36

50-150 mm²

22 mm

AF 6

ML36/MC36

120-300 mm²

Page 14: CATALOGUE 2014 - Aiz · CABLE LUGS & CONNECTORS CATALOGUE ... Medium voltage mechanical aluminum cable lugs The main purpose of bolted lugs is to fix aluminum and copper wires to

AAAIIIZZ

- 13 - www.aiz.lt; www.iospk.ru

Electrical installer memo

MC36 16x95 MC36 95x240 MC36 185x400 MC36 50x150 MC36 120x300

Steps of installation:1. Put and press core centering ring into barrel.2. The connector is pre-greased. Do not remove the grease.3. Strip insulation to fit conductor into barrel.4. Clean and brush conductor and put into barrel. 5. Fasten bolts steadily by hand.6. Fasten bolts slowly with tool according to pictures shown until heads shear off.7. Repeat with second side of connector.8. Screws have to be prerounded if they do not shear off flush with connector body.

l

L

D d

Designationcross-section

MC 36216-95mm

MC 36250-150mm

MC 36295-240mm

MC 362120-300mm

MC 362185-400mm

Allen keysize

screw/unscrew

13 mmAF 6

17 mmAF 6

18 mmAF 6

22 mmAF 6

22 mmAF 6

Centring sleeve 1 clr. none 1 clr. 2 clr. none 1 clr. 2 clr. none 1 clr. none 1 clr. none

Round solidAlCu

RE: 10-50 70-90 50 70-95 120-150 95 120-150 185-240 120-185 240-300 185-240 300-400

Sector solidAlCu

SE: 16-50 70-95 50 70-95 120-150 95 120-150 185-240 120-185 240-300 185-245 300-400

Round strandedAlCu

RM:16-5010-50

70-9050

35-5070-95 95-150 95 120-150 185-240 120-185 240-300 185-240 300-400

Round stranded and compressed

AlCu

RMV: 16-50 70-95 35-50 70-95 120-150 95-120 150 185-240 120-185 240-300 185-240 300-400

Sector strandedAlCu

SM: 25-35 50-90 50 50-70 95-150 95 95-120 150-240 120-150 185-240 185 240-300

Designation

cross-section

Bolt size,

Allen key size

Centring

sleeveBlue none Yellow Gray none Red Brown none Gray none Gray none

Round

solid

Al

CuRE: 10-50 70-90 50 70-95 120-150 95 120-150 185-240 120-185240-300 185-240 300-400

Sector

solid

Al

CuSE: 16-50 70-95 50 70-95 120-150 95 120-150 185-240 120-185240-300 185-245 300-400

Round

stranded

Al

Cu RM:16-50

10-5070-90

50

35-5070-95 95-150 95 120-150 185-240 120-185240-300 185-240 300-400

Round

Stranded

and

compressed

Al

CuRMV: 16-50 70-95 35-50 70-95 120-150 95-120 150 185-240 120-185240-300 185-240 300-400

Sector

stranded

Al

CuSM: 25-35 50-90 50 50-70 95-150 95 95-120 150-240 120-150185-240 185 240-300

ML36/MC36

95-240 mm²

18 mm

AF 6

22 mm

AF 6

ML36/MC36

185-400 mm²

13 mm

AF 6

ML36/MC36

16-95mm²

17 mm

AF 6

ML36/MC36

50-150 mm²

22 mm

AF 6

ML36/MC36

120-300 mm²

Page 15: CATALOGUE 2014 - Aiz · CABLE LUGS & CONNECTORS CATALOGUE ... Medium voltage mechanical aluminum cable lugs The main purpose of bolted lugs is to fix aluminum and copper wires to

UAB “AIZ”

DARIAUS AND GIRENO STR. 107LT-02189 VILNIUS, LITHUANIA, EU

PHONE NO.: +370 62749925

FAX NO: +370 5 235 0342

e-mail:[email protected]@aiz.com

www.aiz.lt

CA