23
1REVISIONS:
TITLE: DESIGN CRITERIA
1/15SHEET:
NONE
DATE:
SCALE:
PROJECT: 2018196LOCATION:3190 BENET LANECOLORADO SPRINGS, CO 80921
06/18/2018
CLIENT: BENET HILL MONASTERY
285 ENGINEERINGP.O. BOX 1048CONIFER, CO
80433(720)-515-1781
23
1REVISIONS:
TITLE: PROJECT SITE PLAN
2/15SHEET:
SHOWNSCALE:
DATE:
PROJECT: 2018196LOCATION:3190 BENET LANECOLORADO SPRINGS, CO 80921
06/18/2018
CLIENT: BENET HILL MONASTERY
285 ENGINEERINGP.O. BOX 1048CONIFER, CO
80433(720)-515-1781
23
1REVISIONS:
TITLE: SUBSURFACE CONDITIONS
3/15SHEET:
SHOWNSCALE:
DATE:
PROJECT: 2018196LOCATION:3190 BENET LANECOLORADO SPRINGS, CO 80921
06/18/2018
CLIENT: BENET HILL MONASTERY
285 ENGINEERINGP.O. BOX 1048CONIFER, CO
80433(720)-515-1781
23
1REVISIONS:
TITLE: SYSTEM 1 SITE PLAN
4/15SHEET:
SHOWNSCALE:
DATE:
PROJECT: 2018196LOCATION:3190 BENET LANECOLORADO SPRINGS, CO 80921
06/18/2018
CLIENT: BENET HILL MONASTERY
285 ENGINEERINGP.O. BOX 1048CONIFER, CO
80433(720)-515-1781
23
1REVISIONS:
TITLE: SYSTEM 2 SITE PLAN
5/15SHEET:
SHOWNSCALE:
DATE:
PROJECT: 2018196LOCATION:3190 BENET LANECOLORADO SPRINGS, CO 80921
06/18/2018
CLIENT: BENET HILL MONASTERY
285 ENGINEERINGP.O. BOX 1048CONIFER, CO
80433(720)-515-1781
23
1REVISIONS:
TITLE: SYSTEM 3 SITE PLAN
6/15SHEET:
SHOWNSCALE:
DATE:
PROJECT: 2018196LOCATION:3190 BENET LANECOLORADO SPRINGS, CO 80921
06/18/2018
CLIENT: BENET HILL MONASTERY
285 ENGINEERINGP.O. BOX 1048CONIFER, CO
80433(720)-515-1781
23
1REVISIONS:
TITLE: SYSTEM 4 SITE PLAN
7/15SHEET:
SHOWNSCALE:
DATE:
PROJECT: 2018196LOCATION:3190 BENET LANECOLORADO SPRINGS, CO 80921
06/18/2018
CLIENT: BENET HILL MONASTERY
285 ENGINEERINGP.O. BOX 1048CONIFER, CO
80433(720)-515-1781
23
1REVISIONS:
TITLE: ADVANTEX SYSTEM PLAN DETAIL
8/15SHEET:
SHOWNSCALE:
DATE:
PROJECT: 2018196LOCATION:3190 BENET LANECOLORADO SPRINGS, CO 80921
06/18/2018
CLIENT: BENET HILL MONASTERY
285 ENGINEERINGP.O. BOX 1048CONIFER, CO
80433(720)-515-1781
23
1REVISIONS:
TITLE: ADVANTEX SYSTEM PROFILE
9/15SHEET:
SHOWNSCALE:
DATE:
PROJECT: 2018196LOCATION:3190 BENET LANECOLORADO SPRINGS, CO 80921
06/18/2018
CLIENT: BENET HILL MONASTERY
285 ENGINEERINGP.O. BOX 1048CONIFER, CO
80433(720)-515-1781
23
1REVISIONS:
TITLE: DRIP DISPERSAL PLAN DETAIL
10/15SHEET:
SHOWNSCALE:
DATE:
PROJECT: 2018196LOCATION:3190 BENET LANECOLORADO SPRINGS, CO 80921
06/18/2018
CLIENT: BENET HILL MONASTERY
285 ENGINEERINGP.O. BOX 1048CONIFER, CO
80433(720)-515-1781
23
1REVISIONS:
TITLE: DRIP DISPERSAL PLAN VIEW
11/15SHEET:
SHOWNSCALE:
DATE:
PROJECT: 2018196LOCATION:3190 BENET LANECOLORADO SPRINGS, CO 80921
06/18/2018
CLIENT: BENET HILL MONASTERY
285 ENGINEERINGP.O. BOX 1048CONIFER, CO
80433(720)-515-1781
23
1REVISIONS:
TITLE: DRIP DISPERSAL PLAN VIEW
12/15SHEET:
SHOWNSCALE:
DATE:
PROJECT: 2018196LOCATION:3190 BENET LANECOLORADO SPRINGS, CO 80921
06/18/2018
CLIENT: BENET HILL MONASTERY
285 ENGINEERINGP.O. BOX 1048CONIFER, CO
80433(720)-515-1781
23
1REVISIONS:
TITLE: DRIP DISPERSAL PLAN VIEW
13/15SHEET:
SHOWNSCALE:
DATE:
PROJECT: 2018196LOCATION:3190 BENET LANECOLORADO SPRINGS, CO 80921
06/18/2018
CLIENT: BENET HILL MONASTERY
285 ENGINEERINGP.O. BOX 1048CONIFER, CO
80433(720)-515-1781
23
1REVISIONS:
TITLE: DRIP DISPERSAL PUMP SYSTEM
14/15SHEET:
SHOWNSCALE:
DATE:
PROJECT: 2018196LOCATION:3190 BENET LANECOLORADO SPRINGS, CO 80921
06/18/2018
CLIENT: BENET HILL MONASTERY
285 ENGINEERINGP.O. BOX 1048CONIFER, CO
80433(720)-515-1781
4"
18" MIN.
504SECTION Not To Scale
GF5043-08-99
23
1REVISIONS:
TITLE: DRIP DISPERSAL DETAIL
15/15SHEET:
SHOWNSCALE:
DATE:
PROJECT: 2018196LOCATION:3190 BENET LANECOLORADO SPRINGS, CO 80921
06/18/2018
CLIENT: BENET HILL MONASTERY
285 ENGINEERINGP.O. BOX 1048CONIFER, CO
80433(720)-515-1781
7525
7530
7535
7515
7520
7525
7530
7515
7515
7520
7520
7525
7525
7510
7515 7520
S 89°55'15"E 605.10S 89°54'25"E 742.84
N 0
°10'
16"W
331
.15
BENET LANE(30' R.O.W. PRIVATE)
UNPLATTEDUNPLATTED
7500
7500
7505
7505
7505
7510
7510
7510
7515751575
15
7525
7530
7525
7515
7520
7525
7535
PROPOSED 20' ASPHALT PAVEMENT
PROPOSEDPARKING LOT
PROPOSED SINGLE FAMILYATTACHED RESIDENTS (TYP)
PROPOSED SINGLE FAMILYATTACHED RESIDENTS (TYP)
24.0
' UTIL
ITYEA
SEM
ENT
24.0
' UTIL
ITYEA
SEM
ENT
LOT 114,592 SF
TRACT B153,278 SF
TRACT C1,750 SF
TRACT D5,909 SF
TRACT E12,420 SF
LOT 23,945 SF
LOT 34,232 SF
LOT 43,696 SF
LOT 53,696 SF
LOT 64,199 SF
LOT 74,329 SF
LOT 84,476 SF
LOT 94,118 SF
LOT 115,047 SF
LOT 124,167 SF
LOT 134,310 SF
LOT 144,312 SF
LOT 154,135 SF
LOT 164,634 SF LOT 17
4,147 SF
LOT 185,041 SF
LOT 194,757 SF
LOT 204,232 SF
LOT 214,232 SF
LOT 224,032 SF
LOT 234,152 SF
LOT 245,279 SF
LOT 254,631 SF
LOT 264,323 SF LOT 27
4,157 SF
EXISTING ASPHALT PAVEMENT EXISTING ASPHALT PAVEMENT
COMMUNITYBUILDING
PROPOSED 20' ASPHALT PAVEMENT
PROPOSED 20'ASPHALT PAVEMENT
PROPOSEDPARKING LOT
PROPOSED SINGLE FAMILYATTACHED RESIDENTS (TYP)
PROPOSED SINGLE FAMILYATTACHED RESIDENTS (TYP)
PROPOSED SINGLE FAMILYATTACHED RESIDENTS (TYP)
24.0
' UTIL
ITYEA
SEM
ENT
24.0
' UTIL
ITYEA
SEM
ENT
LOT 114,592 SF
TRACT B153,278 SF
TRACT C1,750 SF
TRACT D5,909 SF
TRACT E12,420 SF
TRACT F1,825,457 SF41.907 AC
TRACT A
TRACT A
LOT 23,945 SF
LOT 34,232 SF
LOT 43,696 SF
LOT 53,696 SF
LOT 64,199 SF
LOT 74,329 SF
LOT 84,476 SF
LOT 94,118 SF
LOT 104,483 SF
LOT 124,167 SF
LOT 134,310 SF
LOT 144,312 SF
LOT 154,135 SF
LOT 164,634 SF LOT 17
4,147 SF
LOT 185,041 SF
LOT 194,757 SF
LOT 204,232 SF
LOT 214,232 SF
LOT 224,032 SF
LOT 234,152 SF
LOT 245,279 SF
LOT 254,631 SF
LOT 264,323 SF LOT 27
4,157 SF
TRACT F1,825,457 SF41.907 AC
EXISTING ASPHALT PAVEMENT EXISTING ASPHALT PAVEMENT
COMMUNITYBUILDING
44'44'
5'
46'
L 37'
75'
55'
48'
45'
55'
19'L 16' 19' 39'
72'
46' 46'
96'
89'
46'46'
92'
88'
55'55'
84'94'
89'
55'55'
34'
30'
L 16'
82'10
1'
63'
44'46'
45'
L 8' 7'
9'
L 8'22'
46'
18'
95'
94'
92'
92'
92'
12'46'
46'
32'
L 28'98'
98'
66'
22'
53'
41'
48'
55'55'
46'
25'
21'
18'
22'
56'
54'
54'
88'
88'
30'
16'
60'
31'
73'
47'
118'
101'
46'
40'
55'
55'
42'
5'
L 30' 42'L 8'
25'
54'
50'
88'
55'
55'
55'
40'
17'33'
19'
45'
56'
55'
55'
56'
50'
84'
88'
84'
84'
92'
92'
84'
44'
44'
46'
38'
46'
44'
44'
43'
10'77'
24'
L 19
'
24'
L 51
'
103'
72'
39'
119'
71'
104'
L 84'
97'
20'
L 79'
39'
33'
96'
32'
15'
20'
38'12'
128'
160'
L 93'
L 66'26'
PROPOSED DRAINAGE &UTILITY EASEMENT (TYP)
PROPOSED DRAINAGE &UTILITY EASEMENT (TYP)
PROPOSED GARAGES
PROPOSED PARKING
PROPOSED PARKING
BENCHMARK
EN
GIN
EE
RS
S
UR
VE
YO
RS
MV
E, I
NC
.M
VE
, IN
C.
1903 lelaray s
treet, suite 200
colorado
springs co 8
0909 719
.635.573
6
EN
GIN
EE
RS
S
UR
VE
YO
RS
CHECKED BY _____
DESIGNED BY
___________________
CHECKED BY _____ ___________________
REVISIONS
OF
AS-BUILTS BY
MVE DRAWING
MVE PROJECT
DRAWN BY
SHEET
61087
OWTS PLANPRELIMINARY PUD
OWTS-1
SANCTUARY OFPEACE RESIDENTIAL
COMMUNITY
1 1FEBRUARY 21, 2019
VICINITY MAPNOT TO SCALE
SITE
ROLL
ER C
OA
STER
RD
HWY
83
HWY 83
HODGEN RDBAPTISTRD
BENET LN
STAGECOACH RD
CONSTRUCTION DOCUMENT
NOT A
0
1" = 40' 1:480
80402010
LEGEND
FF = 5986.00
PROPERTY LINE
EASEMENT LINE
LOT LINE
BUILDING SETBACK LINE
ADJACENT PROPERTY LINE
EXISTING
INDEX CONTOUR
INTERMEDIATE CONTOUR
CONCRETE AREA
ASPHALT AREA
CURB AND GUTTER
BUILDING/BUILDING OVERHANG
DECK
RETAINING WALL - SOLID/ROCK
SIGN
BOLLARD
WOOD FENCE
CHAIN LINK FENCE
BARBED WIRE FENCE
TREE(EVERGREEN/DECIDUOUS)
SHRUB
ROCK
PROPOSED
INDEX CONTOUR
INTERMEDIATE CONTOUR
CONCRETE AREA
ASPHALT AREA
CURB AND GUTTER
BUILDING/BUILDING OVERHANG
DECK
RETAINING WALL - SOLIDROCK
SIGN
BOLLARD
TOP OF WALL/GRADE AT BOTTOMOF WALL
TOP OF CURB/FLOWLINE
SPOT ELEVATIONFL = FLOWLINETSW = TOP OF SIDEWALK
FINISHED FLOOR ELEVATION
86.0 TW83.0 FG
86.8583.35
84.96TSW
5985
84
5985
84
B B
DETAIL MAP1" = 40'
Z:\6
1087
\_Sh
eet D
wgs
\610
87-D
EV-O
WTS
Pla
n.d
wg,
2/2
2/20
19 2
:14:
04 P
M, C
huck
Cru
m
Markup Summary
Subject: Page Label: 30Author: AutoCAD SHX TextDate: Color:
PURPOSES. IT IS PREPARED FOR THE CITYOF COLORADO
AutoCAD SHX Text (5)
Subject: Page Label: 30Author: AutoCAD SHX TextDate: Color:
PLANS ADHERE TO THE APPROVEDDEVELOPMENT PLAN.
Subject: Page Label: 30Author: AutoCAD SHX TextDate: Color:
THIS PLAN SHALL NOT BE USED FORCONSTRUCTION
Subject: Page Label: 30Author: AutoCAD SHX TextDate: Color:
SPRINGS DEVELOPMENT PLAN APPROVALPROCESS ONLY.
Subject: Page Label: 30Author: AutoCAD SHX TextDate: Color:
IT IS REQUIRED THAT ANY SUBSEQUENTCONSTRUCTION
Subject: CalloutPage Label: 30Author: dsdparsonsDate: 3/28/2019 1:52:38 PMColor:
Place the septic systems in a tract so one canseparate the maintenance.
dsdparsons (4)
Subject: CalloutPage Label: 1Author: dsdparsonsDate: 3/28/2019 1:55:50 PMColor:
CDPHE has comments to be addressed within thisreport. Please work with Aaron D at The County'sHealth Dept as well as CDPHE.
Subject: CalloutPage Label: 1Author: dsdparsonsDate: 3/28/2019 2:05:27 PMColor:
View the report LDC Code 8.4.8 requirements;some of the calculations are missing in the texthere. Also; the figures indicate that the Sisterscurrent system is to be removed from Statessystem and into County's...explain this....
CONSTRUCTION DOCUMENT
NOT A
CONSTRUCTION DOCUMENT
NOT A
CONSTRUCTION DOCUMENT
NOT A
CONSTRUCTION DOCUMENT
NOT A
CONSTRUCTION DOCUMENT
NOT A
75
Place the septicsystems in a tract soone can separate themaintenance.
CDPHE hascomments to beaddressed within thisreport. Please workwith Aaron D at TheCounty's Health Deptas well as CDPHE.
View the report LDC Code8.4.8 requirements; some ofthe calculations are missingin the text here. Also; thefigures indicate that theSisters current system is tobe removed from Statessystem and intoCounty's...explain this....
Subject: CalloutPage Label: 1Author: dsdparsonsDate: 3/28/2019 2:08:23 PMColor:
mention the waivers related to this report....mention the waivers related to this report....