WEIGH IN G SOLU TION S FR OM C EN TR A L C A N A D Awww.cencanscales.ca
General Features- Advanced digital truck scale program with lots of new functions
- Stainless steel enclosure and keys assure longer keypad lifetime
- Complete connectivity with up to 16 digital load cells
- Self diagnostics minimizing possible risks from load cell or communication errors
- Flexible communications with serial, RS232, RS485, Analog Out, Modbus - RTU...
- Dual power supply with AC and 12V external rechargeable battery
Specifications subject to change without notice.
CENCAN SCALES CI100D DIGITAL INDICATOR
Dimension
Keypad
Display
Internal Resolution
Displayed Resolution
Repeatability
Excitation Voltage
Decimal Points
Warm-up Time
Communications
Power Input
Voltage
Frequency
Power Consumption
Scale Types
Calibration
Update Rates
Operating Temperature
Shipping Weight
339(L) x 110(W) x 230(D) mm (13.3 x 4.3 x 9.0 in.), S/S enclosure
30 S/S tactile keys with numeric keys, function keys, application keys
7 digits super-bright LED, 7 status indicator
1,000,000
100,000
±0.01% F.S.
15VDC
Configurable
Self test complete
Two serial ports (RS232/RS485 - RS232/20mA)
Analog Output
Modbus RTU
110-230VAC 10% / 12VDC±
50/60Hz ±10%
45VA max
Power up to 16 x digital load cells
Multi-point calibration
50 per secondO O-10 C - +40 C
4.5 kg (10 lbs)
Technical Specifications
Model CL1D
Lightning Harsh Temperatures Flood Frequency Interference
WEIGH IN G SOLU TION S FR OM C EN TR A L C A N A D A
DescriptionCL1D is canister high accuracy digital load cell, designed
for heavy-duty truck scales, rail scales, tank and silo
weighing applications. Made with industry highest
standards and with exceptional built-in surge arrestors,
CL1D in combination with CI100D digital indicator is the
ideal choice for applications which require harsh-
environment, heavy-duty and high-accuracy.
ApplicationsTruck scales
Rail scale
Tank, hopper, silo weighing
Technical Specifications
www.cencanscales.ca
CENCAN SCALES
Load Cell Type��
Capacity (ton)���
Accuracy���
Communication��
Communication Rate��
Cable Length ����
Cable Length, Home Run��
Warm-up Time from Cold Start�
Temperature - Operating �
Temperature - Compensated�
Working Angle���
Minimum Dead Load��
Combined Error�
Effect of Cable Length on System Accuracy
Zero Balance
Temperature Effect on Minimum Dead Load Output
Humidity Effect, Continuous 100% R.H.
Nonrepeatability
Supply Voltage Regulated in load cell
+ Typical
+ Min / Max
Fatigue Life at R.C. �
Protection���
Safe Load Limit��
Ultimate Load Limit
Construction�
Lightning Protection��
Break down Voltage��
Insulation Resistance��
Column Compression, Digital Weight Processor
30, 40, 50, 60
C4, OIML
RS485 Encrypted
19200bps
16m��
≤ 200m�
10 minutes0 0-30 C - +70 C0 0
-10 C - +40 C0
Max ±3 from vertical
0 kg
< 250ppm R.C.
0 kg (digital signal)
< ±0.1% R.C.0 0
< ±0.8 kg/ C * Vmin (OIML) / 5 C
0 kg (Hemertic Seal)
< ±55 ppm R.C.
7.5 to 15 VDC
7.5 to 20 VDC
> 1,000,000 Cycles
IP68 (1m - 7 days submersion), IP69K Externally Tested
150%
300%
Stainless Steel
Integral TVSS All Lines
≥ 500 VAC
≥ 5000 MΩ @ 50VDC