Page 1: CF-M-Main-Cast-B-0213 Layout 1

Multistage CentrifugalB L O W E R S / E X H A U S T E R S

Page 2: CF-M-Main-Cast-B-0213 Layout 1

Hoffman® and Lamson® brand centrifugals are recognized aroundthe world as the best blower and exhauster solutions for wastewatertreatment applications. For more than 100 years customers have trust-ed the quality performance these legacies provide. Anchored in tradi-tion, this experienced Hoffman and Lamson blower/exhauster lineupremains the most comprehensive offering in the world. Today, as thelargest manufacturer of blowers/exhausters, our number one prioritycontinues to be unparalleled responsiveness to meeting customerneeds. Our unwavering commitment to developing long-term cus-tomer relationships, innovative product designs, and quality manufac-turing is evident with over two hundred thousand units manufac-tured. We are continually improving delivery and response times,while setting the highest performance standards in the industry.Never in the history of blower/exhauster manufacturers has therebeen a company as capable of delivering great value, exceptionalquality and quick turnaround on orders. So the next time you’re eval-uating blower/exhauster options for your application, remember thebest, Hoffman and Lamson brands and give us a call. Our professionalsales representatives are honored to assist you with your applicationchallenges and requirements. These factory trained representativesare conveniently located throughout the United States and aroundthe world.

Blowers & Exhausters that Serve a Wide Range of ApplicationsThe range of applications for Hoffman and Lamson centrifugal prod-ucts is ever-expanding and is firmly illustrated with over 100,000machines in operation. In water & wastewater treatment, air is pro-vided to water and wastewater aeration systems and air scouring/fil-ter backwashing. Hoffman and Lamson blowers can be specified forcoarse/fine bubble diffuser systems, reactor batch supplemental air,digester gas boosters, grit channels and sludge digestion applications.In the industrial market, our blowers provide air or gas for sulfurrecovery, combustion air, process gas boosting, coal mine venting, flu-idized bed combustion systems, vapor and gas extraction, composting,sludge incineration and printing systems, to name a few.

Gardner Denver Engineered Vacuum Systems are used to pick up, con-vey and capture a myriad of materials ranging from aluminum gran-ules to corn flakes. The experienced Gardner Denver team, backed byyears of research and development, provides effective, affordablesolutions for a variety of application needs.

Hoffman® & Lamson®

W O R L D W I D E L E A D E R O F M U L T I S T A G E C E N T R I F U G A L T E C H N O L O G Y

Page 3: CF-M-Main-Cast-B-0213 Layout 1

IndustrialProcessingAeration BasinsAir DryingAir Flotation and SlidingAir Knife StrippingBlow-off SystemsCarbon BlackCoal GasificationCombustion Air BlowersFGD – Forced OxidationFluidized BedGas Boosting

– O², CO², N², etc.Gas RecoveryLandfill GasLNG VaporizersPrinting Operations

– Turning Bars– Dryers– Binding Applications

Pulp DewateringSteel Plating BathsSulfur RecoveryVapor Recompression

Water & WastewaterTreatmentAerationAerobic DigestionBiogasDigester Gas BoostersFilter Backwashing/Air ScouringGrit Chambers

Engineered Vacuum SystemsClean RoomsElectronicsExplosive Dust CollectionFlux RecoveryHousekeepingNuisance Dust CollectionOral EvacuationOSHA Standard RequiredPneumatic ConveyingPowder PaintProduct ReclamationSanitary/Product Quality

– Bakeries– Flour/Grain Mills– Food Products– Pharmaceuticals

Source Capture

Your ApplicationContact us for designassistance for yourunique application.

Blowers & ExhaustersT H A T S E R V E A W I D E R A N G E O F A P P L I C A T I O N S

Page 4: CF-M-Main-Cast-B-0213 Layout 1

Superior QualityI N D E S I G N , M A T E R I A L S A N D W O R K M A N S H I P

Durable, reliable and efficient, Hoffman andLamson centrifugal blowers/exhausters representthe highest quality workmanship in the industryusing the finest materials and state-of-the-artmachining tools available today. Our dedicationto design and quality assures you that theHoffman and Lamson blower you select is thebest in the industry.

5

4

6

7

3

2

1

Page 5: CF-M-Main-Cast-B-0213 Layout 1

5

Multiple Baffle Rings Many models feature ourpatented Multiple BaffleRings (MBR™) which helpturn airflow smoothly intothe eye of the impeller, dra-matically reducing inlet pas-sage losses. MBR combinedwith the two-dimensionalimpeller design increasesblower efficiency and pres-sure/vacuum capability.

Balance PistonA balance piston is locatedat the outlet end of therotating impeller assemblyto compensate for the axialforce of the impellers onthe inlet bearing. Thisgreatly increases bearinglife for longer, trouble-freeoperation.

Flexible CouplingBlowers/exhausters connectdirectly to the powersource with a precisionaligned flexible coupling.This optimizes power trans-fer and minimizes bearingloads for longer life.

Cast HousingBlower housings are preci-sion machined from high-grade cast iron. Smallermodels are cast aluminum.The intermediate blowersections are assembledtogether using highstrength steel tie rods. Theblower and its driver aremounted together on a sin-gle steel baseplate. Thisassures long lasting per-formance and durability.

Multistage Shrouded ImpellersTwo-dimensional shroudedcast aluminum impellers arebalanced individually andkeyed onto the shaft. Onmost blowers, the completeassembly is then balanced toachieve smooth operationwith lowest vibration levelsin the industry. Rotor assem-blies are designed to operatewell below first criticalspeeds for added reliability.

Labyrinth SealNon-contact, non-wearinglabyrinth air seals arestandard. This no-mainte-nance seal is used in mostair and some gas applica-tions (purge option avail-able).

Carbon Ring SealFor special air and gasapplications requiringsuperior sealing, optionalcarbon ring seals are avail-able with purge option.

4

6

7

3

2

1

Page 6: CF-M-Main-Cast-B-0213 Layout 1

Models to 41,000 cfmHoffman and Lamson multistage centrifugal blower/exhauster mod-els cover a broad performance range to meet your needs. Each basemodel presents its own unique performance characteristics anddesign features that are illustrated in the chart below and the airmaps on the following pages.

CF Select™ Precision Sizing ServiceTo help customers select the optimal blower or exhauster for theiroperation, Hoffman and Lamson engineers use CF Select, a comput-erized sizing service. CF Select software can create an infinite num-ber of performance curves for pressure, efficiency, temperature andpower consumption. Based on the specific gas mixture, inlet condi-tions, flow and pressure/vacuum requirements, CF Select chooses themost appropriate model, impeller design, operating speeds or throt-tling options.

Performance & Specifications

Gardner Denver Performance Specifications

Blower Model 260 310 400 510 550 42 732 850 741 870 742

Blower/Exhauster Capacity

Minimum Flow (cfm) 100 60 70 150 200 50 400 550 650 1,000 700

Maximum Flow (cfm) 440 450 1,050 1,300 1,300 1,200 2,400 3,200 4,400 5,500 4,800

Minimum Flow (m³h) 170 405 120 255 340 85 650 935 1,100 1,700 1,200

Maximum Flow (m³/h) 680 765 1,785 2,210 2,210 2,050 4,100 5,440 7,500 9,350 8,100

Maximum Pressure (psig) 8.6 7.4 7.2 11.8 11.8 9.75 15.2 14.7 16 17 20.8

Maximum Pressure (bar) 0.6 0.6 0.51 0.81 0.81 0.67 1.05 1.01 1.1 1.17 1.43

Maximum Vacuum ("Hg) 11.2 11.2 9.9 13.7 13.7 12 15 15.2 15.5 16 18

Maximum Vacuum (mm Hg) 284 284 251 348 348 300 380 386 380 406 450

Maximum Number of Stages 5 11 10 10 10 8 10 9 9 9/10* 11

Design Benefits

Single Baffle Ring

Multiple Baffle Rings (MBR)

Balance Piston

Lubrication Grease Grease Grease Gr/Oil Gr/Oil Gr/Oil Gr/Oil Gr/Oil Gr/Oil Gr/Oil Gr/Oil

Labyrinth Seal

Carbon Ring Seal O O O O O O O

Connections

Inlet (125# ANSI) 2 1/2" 3" 5" 5" 6" 6" 6" 8" 8" 10" 10"

Outlet (125# ANSI) 2 1/2" 3" 5" 5" 5" 6" 6" 8" 8" 8" 8"

Air map data is representative of maximum RPM design for each model with standard conditions at 60 Hz. *Maximum stages at 50 Hz. ** 2 7/8" as cast O.D. (standard), 2 1/2" male N.P.T. or 2 1/2" threaded ANSI flange.

Standard O OptionalContact your Hoffman/Lamson representative for job specific blower sizing.

Page 7: CF-M-Main-Cast-B-0213 Layout 1

Size & Performanceto Fit Your ApplicationWith 22 models to choose from and the ability to specify a variety of manufacturing options, you canbe assured that the blower or exhauster you order will deliver the performance you expect. In addi-tion to the base models available, customers can choose from a variety of design options such as spe-cial coatings, alternative component materials, oil or grease lubrication, special seals, drive couplingsand power sources. The Hoffman and Lamson blower/exhauster you specify is then manufacturedaccording to your unique application and requirements.

Gardner Denver Performance Testing LabHoffman and Lamson blowers and exhausters are tested in our state-of-the-art test facility inPeachtree City, Georgia. Using the most sophisticated testingequipment available in the industry, we test units up to 3,000horsepower in accordance with the latest edition of theASME test code PTC-10, ISO and all other applicable inter-national standards. Units are brought into this two-storylaboratory and connected to a specialized power unit andprecision monitoring equipment. The blower/exhauster isthen tested and evaluated for performance characteristics,noise level and vibration. Overall performance data is cap-tured in real time for performance curve evaluation anddocumentation. We frequently host performance testing forcustomers and inspectors from all over the world.

Blower Model 751 1260 752 1270 761 1400 1600 1870 671 2000 2400

Blower/Exhauster Capacity

Minimum Flow (cfm) 950 1,250 3,250 1,175 1,250 2,300 3,000 3,000 3,500 5,000 10,000

Maximum Flow (cfm) 8,500 8,000 9,00 8,500 14,500 14,500 12,000 15,000 22,800 32,000 40,000

Minimum Flow (m³/h) 1,600 2,125 5,500 2,000 2,100 3,900 5,100 5,100 5,500 8,500 17,000

Maximum Flow (m³/h) 14,500 13,600 15,300 14,400 24,600 24650 20,400 25,500 35,850 50,800 68,000

Maximum Pressure (psig) 12.5 14.3 19.5 17.3 13 12.6 17 19 19 24.7 22

Maximum Pressure (bar) 0.86 0.99 1,35 1.2 0.9 0.87 1.17 1.31 1.31 1.7 1.52

Maximum Vacuum ("Hg) 13.7 14.8 17 16.2 14 13.8 16 17 17 18.8 17.6

Maximum Vacuum (mm Hg) 350 375 425 412 350 351 406 432 432 477 447

Maximum Number of Stages 7 8 10 8/9* 7 7/8* 7/8* 7 7/8* 7/8* 5/6*

Design Benefits

Single Baffle Ring

Multiple Baffle Rings (MBR)

Balance Piston

Lubrication Oil Oil Oil Oil Oil Oil Oil Oil Oil Oil Oil

Labyrinth Seal

Carbon Ring Seal O O O O O O O O O O

Connections

Inlet (125# ANSI) 12" 12" 14" 14" 14" 18" 16" 20" 20" 20" 24"

Outlet (125# ANSI) 12" 12" 10" 12" 14" 14" 14" 18" 18" 18" 20"

Gardner Denver Performance Specifications

Page 8: CF-M-Main-Cast-B-0213 Layout 1

Choose From Multiple Drive OptionsHoffman and Lamson blowers and exhaustersmay be direct driven, V-belt driven or gearboxdriven with an electric motor. Alternative driversinclude steam turbines, diesel engines, gasolineengines and liquid petroleum or methane gasengines. Also available is the Next GenerationControls (NGC) variable frequency drive system.The NGC system automatically adjusts airflowoutput to match the actual airflow demand. Theblower/exhauster power requirement adjustsautomatically resulting in energy savings. YourHoffman and Lamson representative can workwith you to determine the best drive option andconfiguration to match your application.

Page 9: CF-M-Main-Cast-B-0213 Layout 1

Air MapsH O F F M A N & L A M S O N M O D E L S 4 2 – 7 3 2

Page 10: CF-M-Main-Cast-B-0213 Layout 1

Air MapsH O F F M A N & L A M S O N M O D E L S 7 4 1 – 1 2 7 0

Page 11: CF-M-Main-Cast-B-0213 Layout 1

Air MapsH O F F M A N & L A M S O N M O D E L S 7 6 1 – 2 4 0 0

Page 12: CF-M-Main-Cast-B-0213 Layout 1

Whether you’re responsible for awastewater treatment plant, thesmelting operation at a foundry orthe precise material handlingneeds of a manufacturing facility,our control systems are designedto properly operate your Hoffmanand Lamson blowers andexhausters and protect them fromconditions that may lead to cata-strophic mechanical failure, costlydowntime or voiding your manu-facturer’s warranty. Our state-of-

the-art control systems and moni-tors provide you with the protec-tion and information you need tokeep your operation running atpeak efficiency.

Our control systems can monitor avariety of conditions that includemotor current, motor temperature,blower vibration, bearing temper-ature, bearing oil level, dischargeair temperature, inlet vacuum andoutlet pressure.

Genuine Hoffman & Lamson Factory Service & Parts

Hoffman & Lamson Monitoring & Control Systems

• Factory TrainedService Professionals

• On-site, On-Demand Service• System Optimization• Blower Remanufacturing• Training, Troubleshooting

and Consulting• Warranty Renewal Programs

• Genuine GD QualityReplacement Parts

• Highest Quality Lubricants– AEON® Centrifugal

Lubricating Grease– AEON CF-46 Centrifugal

Blower Oil

Accessories

• Engines• Motors• Turbines• Variable Frequency Drives• Butterfly Valves• Check Valves

• Filters• Silencers• Expansion Joints• Gauges• SmartMeter• Blower Control Panels

Please recycle after use.

[email protected]

Gardner Denver Nash PO Box 130 Bentleyville, PA 15314 USANew Equipment Sales: (800) 543-7736 Aftermarket Parts Sales: (800) 982-3009

Phone: +1 724-239-1500 Fax: +1 724-239-1502

©2013 Gardner Denver NashCF-M-CAST-B-0213

Specifications subject to change without notice.