of 21
8/9/2019 Cme2100 Quick Manual English v.3.0 0
1/59
CMe2100 Quick Manual English v3.0 Page | 1
CMe2100 Quick Manual CMe2100
EnglishVersion 3.0
Get the complete manual online at www.elvaco.com
8/9/2019 Cme2100 Quick Manual English v.3.0 0
2/59
Page | 2 Support: +46 300 434300 [email protected]
Contents
1 DOCUMENT NOTES..........................................................................2 INTRODUCTION ................................................................................3
MOUNTING .......................................................................................4 CONFIGURE FOR E-MAIL REPORTS .................................................5 CONFIGURE FOR FTP REPORTS .......................................................6 CONFIGURE FOR HTTP REPORTS ....................................................7 CONFIGURE FOR TRANSPARENT M-BUS ........................................8 RESET TO FACTORY DEFAULT.........................................................
9
CHANGING CONFIGURATION ..........................................................10 LED INDICATIONS.............................................................................11 TROUBLESHOOTING ........................................................................12 REPORT TEMPLATES ........................................................................13 COMMAND LISTING .........................................................................14 TECHNICAL SPECIFICATIONS ..........................................................
15
SAFETY AND ENVIRONMENT ..........................................................16
ACCESSORIES AND SIMILAR PRODUCTS .......................................
8/9/2019 Cme2100 Quick Manual English v.3.0 0
3/59
CMe2100 Quick Manual English v3.0 Page | 3
1 Document notes
All information in this manual, including product data, diagrams, charts,
etc. represents information on products at the time of publication, and issubject to change by Elvaco AB without notice. It is recommended thatcustomers contact Elvaco AB to find out the latest available documentation.Elvaco AB assumes no responsibility for technical inaccuracies,typographical errors or any damage, liability, or other losses by use ofthis product.
© 2011, Elvaco AB. All rights reserved. No part of the contents of this manual may betransmitted or reproduced in any form by any means without the written permissionof Elvaco AB. Printed in Sweden.
8/9/2019 Cme2100 Quick Manual English v.3.0 0
4/59
Page | 4 Support: +46 300 434300 [email protected]
This manual provides information needed to get started with theCMe2100 product.
CMe2100 version appliance: >= 1.2.0
For a complete description of the CMe2100 product, download the fullmanual from Elvaco AB web site, www.elvaco.com.
http://www.elvaco.com/http://www.elvaco.com/
8/9/2019 Cme2100 Quick Manual English v.3.0 0
5/59
CMe2100 Quick Manual English v3.0 Page | 5
1.1
Contact information
Elvaco AB Headquarter
Teknikgatan 18434 37 KungsbackaSWEDEN
Phone: +46 300 30250Fax: +46 300 18440E-Mail: [email protected]
Elvaco AB Technical Support
Phone: +46 300 434300E-Mail: [email protected]: www.elvaco.com
mailto:[email protected]://www.elvaco.com/http://www.elvaco.com/mailto:[email protected]
8/9/2019 Cme2100 Quick Manual English v.3.0 0
6/59
Page | 6 Support: +46 300 434300 [email protected]
2 Introduction
The CMe2100 is a stand-alone, DIN-mounted GSM/GPRS equipmentwith M-Bus master, intended to read and store values from any metersupporting the M-Bus protocol.
The CMe2100 is available in the following variants:
CMe2100 GPRS M-Bus terminal with M-Bus 2-wire interface andE-Mail support
8/9/2019 Cme2100 Quick Manual English v.3.0 0
7/59
CMe2100 Quick Manual English v3.0 Page | 7
2.1
Key features
Read and store meter data from ABB electricity meters withIR interface or any slaves supporting the M-Bus standard protocol
Connect up to 8 M-Bus slaves, extendable using CMeX Series Send a variety of meter data reports using E-Mail, FTP, HTTP and SMS Transparent M-Bus using TCP and GSM data Configurable using SMS ,Telnet and HTTP Remotely upgradable application and firmware
Manufacturer specific report templatesThe CMe2100 fits into almost any kind of meter collecting system, i.e.remote reading for M-Bus compatible electricity meters, water meters,gas meters, temperature meters, heat meters etc.
8/9/2019 Cme2100 Quick Manual English v.3.0 0
8/59
Page | 8 Support: +46 300 434300 [email protected]
2.2
Overview
1. Serial number2. Button3.
M-Bus connector4. Antenna SMA connec
5.
M-Bus IR interface
8/9/2019 Cme2100 Quick Manual English v.3.0 0
9/59
CMe2100 Quick Manual English v3.0 Page | 9
6.
GSM LED (Yellow)7. Error LED (Red)8.
Status LED (Green)9. SIM card holder10. Service interface11.
Power supply N
12.
Power supply L
8/9/2019 Cme2100 Quick Manual English v.3.0 0
10/59
Page | 10 Support: +46 300 434300 [email protected]
3 Mounting
The CMe2100 should be mounted on a DIN-rail. The metallic clip on thebottom is used to mount and demount the unit from the DIN-rail. Forsafety reasons, a DIN-rail enclosure must cover the terminals.
3.1 SIM card
Install the GSM SIM card into the SIM card holder (9). Remember thephone number for later use.
IMPORTANT
The SIM card shall not have any PIN code activated The SIM card must have GPRS internet access activated for full
functionality
If a prepaid SIM card is used, ensure that enough credits are availab
8/9/2019 Cme2100 Quick Manual English v.3.0 0
11/59
CMe2100 Quick Manual English v3.0 Page | 11
3.2
Antenna
The antenna should be connected to the SMA connector (4). Dependingon signal strength and environment, a different antenna with extension
cable can be used. Torque should be finger tight.
IMPORTANT
Do not mount the antenna close to any metallic objects Do not mount the antenna close to the M-Bus 2-wire bus
Do not mount the antenna inside a metallic cabinet
3.3 M-Bus 2-wire bus
M-Bus is a multi-drop 2-wire bus with no polarity. A cable of eithershielded (typically 4 x 0.8 mm diam./0.5 mm2) telephone type orstandard mains type (1.5 mm2) should be used. Connect the wiring tothe connector (3). Do not exceed the maximum cable length of 1000 m.
http://en.wiktionary.org/wiki/tightenhttp://en.wiktionary.org/wiki/tighten
8/9/2019 Cme2100 Quick Manual English v.3.0 0
12/59
Page | 12 Support: +46 300 434300 [email protected]
IMPORTANT
The internal M-Bus interface can handle up to 8 slaves. Overloadingthe bus causes communication problems with the connected slaves.
All connected slaves must have unique M-Bus secondary addresses.
3.4 IR interface with ABB electricity meters or
CMeX Series modules
When the IR interface will be used beside an ABB electricity meter or
CMeX module, the IR shield (5) should be removed. The CMe2100should be mounted on the left side of the ABB electricity meter or CMemodule. There shall be no space between the CMe2100 and the ABBelectricity meter or CMeX module. (Do not remove the shield if not usebeside an ABB electricity meter or CMeX module.)
8/9/2019 Cme2100 Quick Manual English v.3.0 0
13/59
CMe2100 Quick Manual English v3.0 Page | 13
3.5
Power supply
The main supply should be connected to the power supply screwterminals (11) and (12). Main supply voltage should be in the range of
100-240 VAC, 50/60 Hz. The CMe2100 will be running factory defaultsettings when first powered up.
An emergency circuit breaker should be used in order to ensure safeseparation of the CMe2100 product from the main power supply.
The next chapters cover the configuration of the CMe2100 product. If anyproblem occurs during configuration, please refer to theTroubleshooting section on page 33 .
8/9/2019 Cme2100 Quick Manual English v.3.0 0
14/59
Page | 14 Support: +46 300 434300 [email protected]
4 Configure for E-Mail reports
This section describes how to enable the CMe2100 product to sendE-Mail reports of connected slaves to one or more E-Mail recipients. ThCMe2100 product will store hourly values of connected slaves, sendvalue reports every day at 00:00 and send an E-Mail installation reporton completion.
4.1 Set E-Mail recipients
SMS to CMe2100 product: qset email
Example: qset email [email protected],[email protected]
The CMe2100 product will acknowledge with an SMS receipt.
mailto:[email protected],[email protected]:[email protected],[email protected]
8/9/2019 Cme2100 Quick Manual English v.3.0 0
15/59
CMe2100 Quick Manual English v3.0 Page | 15
4.2
Search and install M-Bus slaves
The CMe2100 product will search and install M-Bus slaves using primaryand secondary addressing on 2400 baud and synchronize time with an
internet time server.
SMS to CMe2100 product: install
Parameter description:
- Number of slaves to find. Not mandatory
- Configuration profile name. Not mandatory - Use word keep to keep existing slaves and clean toremove all slaves before searching for new.
8/9/2019 Cme2100 Quick Manual English v.3.0 0
16/59
Page | 16 Support: +46 300 434300 [email protected]
Examples:Install and search for 2 meters and use profile myprofile :install 2 myprofile
Install and search for 2 meters:install 2
Clean all existing meters and install and search for 2 meters:install 2 clean
Keep all existing meters and install and search for 2new
meters:install 2 keep
Install and search for unknown number of meters:install
The CMe2100 product is now configured and will by default send E-Ma
value reports of connected slaves every day at 00:00.
8/9/2019 Cme2100 Quick Manual English v.3.0 0
17/59
CMe2100 Quick Manual English v3.0 Page | 17
5 Configure for FTP reports
This section describes how to enable the CMe2100 product to send FTPreports of connected slaves to an FTP server. The CMe2100 product willstore hourly values of connected slaves, send value reports every day at00:00 and send an E-Mail installation report on completion (if E-Mail isconfigured, see page 14 ).
5.1 Set FTP server
SMS to CMe2100 product: qset ftp
Example: qset ftp ftp.domain.com 21 user pass datafolder
The CMe2100 product will acknowledge with an SMS receipt.
ftp://ftp.domain.com/ftp://ftp.domain.com/
8/9/2019 Cme2100 Quick Manual English v.3.0 0
18/59
Page | 18 Support: +46 300 434300 [email protected]
5.2
Search and install M-Bus slaves
First perform steps as described on page 15.
FTP reports must be manually activated.
Examples:Activate to send FTP reports every day using report template 2104:sch report2 1day 2104
Activate to send FTP reports every hour using report template 2104:sch report2 1hour 2104
Activate to send FTP reports every month using report template 2105:sch report2 1month 2105
8/9/2019 Cme2100 Quick Manual English v.3.0 0
19/59
CMe2100 Quick Manual English v3.0 Page | 19
6 Configure for HTTP reports
This section describes how to enable the CMe2100 product to sendHTTP POST reports of connected slaves to a web server. The CMe2100product will store hourly values of connected slaves, send value reportsevery day at 00:00 and send an E-Mail installation report on completion(if E-Mail is configured, see page 14 ).
6.1 Set HTTP server
SMS to CMe2100 product: qset http
Example: qset http http://www.domain.com user pass basic
The CMe2100 product will acknowledge with an SMS receipt.
http://www.domain.com/http://www.domain.com/
8/9/2019 Cme2100 Quick Manual English v.3.0 0
20/59
Page | 20 Support: +46 300 434300 [email protected]
6.2
Search and install M-Bus slaves
First perform steps as described on page 15.
HTTP reports must be manually activated.
Examples:Activate to send HTTP reports every day using report template 3104:sch report3 1day 3104
Activate to send HTTP reports every hour using report template 3104:sch report3 1hour 3104
Activate to send HTTP reports every month using report template 3105sch report3 1month 3105
8/9/2019 Cme2100 Quick Manual English v.3.0 0
21/59
CMe2100 Quick Manual English v3.0 Page | 21
7 Configure for transparent M-Bus
This section describes how to enable transparent M-Bus over TCP ordial-up GSM data.
7.1
Configure for transparent M-Bus over
GSM data
SMS to CMe2100 product: qset csd on tmbus
Example: qset csd on tmbus 300
The CMe2100 product will acknowledge with an SMS receipt.
Available baud rates are 300 and 2400. The calling party should use 8data bits, even parity and 1 stop bit (8E1).
8/9/2019 Cme2100 Quick Manual English v.3.0 0
22/59
Page | 22 Support: +46 300 434300 [email protected]
7.2
Configure for transparent M-Bus over TCP
on baud 300
SMS to CMe2100 product:qset tmbus1 on
Or to turn off transparent server:SMS to CMe2100 product: qset tmbus1 off
The CMe2100 product will acknowledge with an SMS receipt. The producwill listen for incoming connections on TCP port 300.
7.3
Configure for transparent M-Bus over TCP
on baud 2400
SMS to CMe2100 product: qset tmbus2 on
The CMe2100 product will acknowledge with an SMS receipt. The producwill listen for incoming connections on TCP port 2400.
8/9/2019 Cme2100 Quick Manual English v.3.0 0
23/59
CMe2100 Quick Manual English v3.0 Page | 23
8 Reset to factory default
In order to reset the CMe2100 product configuration to factory default,press and hold the button on power-up until the green and red LED
lights flashes fast. Then release the button and the CMe2100 product willreset to factory default configuration and restart.
The CMe2100 product can also be reset to factory default using SMS.
SMS to CMe2100 product: factoryreset
Example: factoryreset
The CMe2100 product will acknowledge with an SMS receipt.
8/9/2019 Cme2100 Quick Manual English v.3.0 0
24/59
Page | 24 Support: +46 300 434300 [email protected]
9 Changing configuration
9.1 Manually set network parameters
How to manually set network configuration if the Auto APN is notavailable or a specific network setting is needed, i.e. static public IP AP
SMS to CMe2100 product: qset net
Example: qset net online.telia.se guest guest
The CMe2100 product will acknowledge with an SMS receipt.
SMS to revert to Auto APN: qset net
Reverting to Auto APN also reverts to Auto SMTP.
8/9/2019 Cme2100 Quick Manual English v.3.0 0
25/59
CMe2100 Quick Manual English v3.0 Page | 25
9.2
Manually set SMTP server
How to manually set SMTP server if the Auto SMTP is not available or aspecific SMTP server setting is needed:
SMS to CMe2100 product: qset email
Example: qset email [email protected] smtpserver.domain.com 25 user password
The CMe2100 product will acknowledge with an SMS receipt.
SMS to revert to Auto SMTP: qset email
Reverting to Auto SMTP also reverts to Auto APN.
8/9/2019 Cme2100 Quick Manual English v.3.0 0
26/59
Page | 26 Support: +46 300 434300 [email protected]
9.3
Change slave log interval
How to change the interval for the CMe2100 product to read and storevalues of installed slaves:
SMS to CMe2100 product: sch storevalue
Example: sch storevalue 10min
The CMe2100 product will acknowledge with an SMS receipt.
Available intervals: 1min, 5min, 10min, 15min, 20min, 30min, 1hour,12hour, 1day, 1week, 1month
8/9/2019 Cme2100 Quick Manual English v.3.0 0
27/59
CMe2100 Quick Manual English v3.0 Page | 27
9.4
Change M-Bus search mode and baud rate
How to change the M-Bus search configuration:
SMS to CMe2100 product: qset mbus
Example: qset mbus primary,secondary 300,2400
The CMe2100 product will acknowledge with an SMS receipt.
Available searchmode: primary,secondaryAvailable searchbaud: 300, 600, 1200, 2400, 4800, 9600
8/9/2019 Cme2100 Quick Manual English v.3.0 0
28/59
Page | 28 Support: +46 300 434300 [email protected]
9.5
Change report schedule or template
How to change the interval and template for a report configuration:
SMS to CMe2100 product: sch report1 [template]Or to turn off report schedule:SMS to CMe2100 product: sch report1 off
Example: sch report1 10min 1104
The CMe2100 product will acknowledge with an SMS receipt.
Available intervals: 1min, 5min, 10min, 15min, 20min, 30min, 1hour,12hour, 1day, 1week, 1monthAvailable templates: See page 42. Leaving out the template parameter,will keep current template setting.
Changing report interval doesn’t change slave log interval, see page 26
8/9/2019 Cme2100 Quick Manual English v.3.0 0
29/59
CMe2100 Quick Manual English v3.0 Page | 29
9.6
Get product status information
How to get a variety of information on the CMe2100 product:
SMS to CMe2100 product: status
Example: status net
The CMe2100 product will respond with an SMS of common statusinformation.
Available requests: common, prepaid, net, module, ver
8/9/2019 Cme2100 Quick Manual English v.3.0 0
30/59
Page | 30 Support: +46 300 434300 [email protected]
9.7
Change time UTC offset
How to set the local time offset from UTC:
SMS to CMe2100 product: set common.time.utcoffset=
Example: set common.time.utcoffset=2
The CMe2100 product will acknowledge with an SMS receipt.
Offset range: -11 to 11
CMe2100 currently does not support daylight savings.
8/9/2019 Cme2100 Quick Manual English v.3.0 0
31/59
CMe2100 Quick Manual English v3.0 Page | 31
9.8
Request a specific report
How to manually request a report without scheduling the report:
SMS to CMe2100 product: report orSMS to CMe2100 product: report
Example: report 1004
The CMe2100 product will send report 1004 (System log) to configuredE-Mail recipients.
Available intervals: 1min, 5min, 10min, 15min, 20min, 30min, 1hour,12hour, 1day, 1week, 1monthAvailable templates: See page 42.
8/9/2019 Cme2100 Quick Manual English v.3.0 0
32/59
Page | 32 Support: +46 300 434300 [email protected]
9.9
Change password
How to change password for security level 1 to enable passwordsecurity for all communication with the CMe2100 product:
SMS to CMe2100 product:set common.security.password1=
Example: set common.security.password1=1234
The CMe2100 product will acknowledge with an SMS receipt.
Default password is blank. Default password for security level 2 is 222and for security level 3 is 3333. When password for security level 1 isset, all SMS messages must start with and new line.
8/9/2019 Cme2100 Quick Manual English v.3.0 0
33/59
CMe2100 Quick Manual English v3.0 Page | 33
10 LED indications
The CMe2100 product is equipped with three LEDs. The red LEDindicates error, the green LED show currents operation and the yellow
LED indicates GSM/GPRS modem activity. See following pages for LEDindication explanations. Green and Red operation LEDs:
Off/RestartGreen LED (Off)
Red LED (Off)
Power OnGreen LED (On)
Red LED (On)
Normal operationGreen LED (Short dip)
Red LED (Off)
8/9/2019 Cme2100 Quick Manual English v.3.0 0
34/59
Page | 34 Support: +46 300 434300 [email protected]
Green and Red operation LEDs continued:
M-Bus short-circuitGreen LED (Short dip)
Red LED (On)
No SIM installedGreen LED (Short dip)
Red LED (50/50)
No GSM networkGreen LED (Short dip)
Red LED (Short flash)
8/9/2019 Cme2100 Quick Manual English v.3.0 0
35/59
CMe2100 Quick Manual English v3.0 Page | 35
11 Troubleshooting
11.1 All LEDs are permanently off
There is a problem with the supply voltage. Please verify 100-240 VAC. Ifthe problem persists, the product may be malfunctioning. Please contactElvaco support.
11.2 Red LED is permanently on
This indicates an error on the M-Bus 2-wire bus.
Please verify no short-circuit of the M-Bus bus. The voltage of the busshould be between 24 VDC and 30 VDC.
8/9/2019 Cme2100 Quick Manual English v.3.0 0
36/59
Page | 36 Support: +46 300 434300 [email protected]
11.3
Red LED is flashing 50/50
This indicates a SIM card error. Please verify:
SIM card has no PIN code activated
SIM card is activated SIM card contact areas are clean
LED Indication
No SIM installed
Green LED(Short dip)
Red LED(50/50)
8/9/2019 Cme2100 Quick Manual English v.3.0 0
37/59
CMe2100 Quick Manual English v3.0 Page | 37
11.4
Red LED is flashing short
No GSM network coverage/unable to attach to GSM network. Please verify:
Antenna installation
o
Installation with bad network coverage sometimes requires anexternal antenna. Do not mount antenna inside metallic cabinets
SIM card activated SIM card contact areas are clean
LED Indication
No GSM network
Green LED(Short dip)
Red LED(short flash)
8/9/2019 Cme2100 Quick Manual English v.3.0 0
38/59
6 I ll d d fi d
8/9/2019 Cme2100 Quick Manual English v.3.0 0
39/59
CMe2100 Quick Manual English v3.0 Page | 39
11.6
Install command does not find any meters
Please verify your M-Bus slave configuration:
Voltage over M-Bus slave should be between 24 VDC and 30 VDC All M-Bus slaves must have unique secondary addresses M-Bus slave baud rates
o Default search baud is 2400, please see command qset mbus,page 27, how to change the searched baud rates
11 7 S i di APN
8/9/2019 Cme2100 Quick Manual English v.3.0 0
40/59
Page | 40 Support: +46 300 434300 [email protected]
11.7
Status report indicates no APN
This may be due to Auto APN detection has no information about yournetwork provider. Please contact your network provider for the followi
internet access information:
APN Optional APN username Optional APN password
Set network parameters manually using command qset net, see page 24
11 8 E M il ti i fi d b t
8/9/2019 Cme2100 Quick Manual English v.3.0 0
41/59
CMe2100 Quick Manual English v3.0 Page | 41
11.8
E-Mail reporting is configured but no
E-Mails are sent
This may be due to the following reasons:
No or wrong SMTP server is auto detected. Please verify commandstatus, see page 29. If the SMTP server is not set, please set theSMTP server manually using command qset email, see page 25.
No valid recipients set. Set recipients with command qset email,see page 25.
Report is not correctly activated, please configure E-Mail reports withcommand sch, see page 28.
If you still have problems getting your CMe2100 running, please contactElvaco support, see page 5.
12 R t t l t
8/9/2019 Cme2100 Quick Manual English v.3.0 0
42/59
Page | 42 Support: +46 300 434300 [email protected]
12 Report templates
Get the complete report template documentation on Elvaco web site.
Report Id DescriptionSMS Reports
1 Installation report
E-Mail Reports
1001 Installation report (HTML)
1002 Installation report (PLAIN)
1003 System report (HTML) 1004 System log report (HTML)
1005 Event report (HTML)
1006 Log report (HTML, machine friendly in CSV attached file of E-Mail)
1007 Monitor event report (HTML)
1101 Value report (HTML, human readable in body of E-Mail)
1102 Value report (HTML machine friendly in body of E-Mail)
8/9/2019 Cme2100 Quick Manual English v.3.0 0
43/59
CMe2100 Quick Manual English v3.0 Page | 43
1102 Value report (HTML, machine friendly in body of E Mail)
1103 Value report (HTML, machine friendly in CSV attached files of E-Mail)
1104 Value report (HTML, human readable in CSV attached files of E-Mail) 1105 Value report (HTML, machine friendly in CSV attached files of E-Mail
+ extra column header indicator) 1106 Value report (HTML, machine friendly with zip extension (not zipped)
attached files of E-Mail + extra column header indicator) 1107 Value report with energy consumption (HTML, machine friendly in
CSV attached files of E-Mail) 1108 Value report (HTML, machine friendly in CSV attached file of E-Mail +
extra column header indicator)
FTP Reports2101 Value report (human readable in a single CSV files)
2102 Value report (machine friendly CSV files)
2103 Value report (machine friendly CSV files)
2104 Value report (human readable CSV files)
2105 Value report (human readable CSV files + extra column header
indicator)
2108 Value report (machine friendly in CSV file + extra column header
8/9/2019 Cme2100 Quick Manual English v.3.0 0
44/59
Page | 44 Support: +46 300 434300 [email protected]
2108 Value report (machine friendly in CSV file + extra column headerindicator)
HTTP Reports
3101 Value report (human readable in a single CSV POST)
3102 Value report (machine friendly CSV POSTs)
3103 Value report (machine friendly CSV POSTs)
3104 Value report (human readable CSV POSTs)
3105 Value report (human readable CSV POSTs + extra column headerindicator)
3108 Value report (machine friendly CSV POST + extra column headerindicator)
13 Command listing
8/9/2019 Cme2100 Quick Manual English v.3.0 0
45/59
CMe2100 Quick Manual English v3.0 Page | 45
13 Command listing
Get the complete command description documentation from Elvaco website.
Command name Description
command1 User definable command 1.
command2 User definable command 2.
command3 User definable command 3.
command4 User definable command 4.
command5 User definable command 5.device Send M-Bus command directly to slave
factoryreset Restore all settings to factory default
fwupdate Update product firmware
get Get a configuration key
install Search for installed slaves
login Login in console or SMS mode
maintenance Maintenance task
8/9/2019 Cme2100 Quick Manual English v.3.0 0
46/59
Page | 46 Support: +46 300 434300 [email protected]
monitor1 User definable monitor 1.
monitor2 User definable monitor 2.
monitor3 User definable monitor 3.
monitor4 User definable monitor 4.monitor5 User definable monitor 5.
qset Quick set configuration
reboot Reboot product
report User definable report.
report1 User definable report 1
report2 User definable report 2report3 User definable report 3
report4 User definable report 4
report5 User definable report 5
set Set a configuration key
sch Schedules a command
status Get status information from the product
8/9/2019 Cme2100 Quick Manual English v.3.0 0
47/59
CMe2100 Quick Manual English v3.0 Page | 47
p
storevalue Read and store value of installed slaves
sysreport Sends system report
logreport Sends system log report
sync Synchronize configuration with synchronize servertimesync Synchronize time with internet timeserver
14 Technical specifications
8/9/2019 Cme2100 Quick Manual English v.3.0 0
48/59
Page | 48 Support: +46 300 434300 [email protected]
14 Technical specifications
14.1 Characteristics
Value Unit Comments Mechanics
Casing material Polyamide -
Protection class IP20 -
Dimensions 100x65x36 mm
Weight 120 g
Connection M-Bus
Pin terminal - Solid wire 0.6-0.8 Ø mm
Electrical
Nominal voltage 100-240 VAC
Power supply Screwterminal
- Cable 0-2.5 mm2, 0.5 Nmtightening torque
Voltage range -10 to +10 % Of nominal voltage
Frequency 50/60 Hz
8/9/2019 Cme2100 Quick Manual English v.3.0 0
49/59
CMe2100 Quick Manual English v3.0 Page | 49
Powerconsumption(Max)
8/9/2019 Cme2100 Quick Manual English v.3.0 0
50/59
Page | 50 Support: +46 300 434300 [email protected]
rangeOperatinghumidity max.
80 %RH Temperatures up to 31°C,decreasing linearly to50%RH at 40°C
Pollution Degree 2 -Operatingaltitude
0-2000 Meters
Usage Indoor useonly
can be extended with IP67enclosure for outdoor use
User interface
Green LED PowerRed LED Error
Yellow LED GSM status -
Push button Factoryreset
-
M-Bus
M-Bus standard EN 13757 - Full M-Bus decoder
implemented
8/9/2019 Cme2100 Quick Manual English v.3.0 0
51/59
CMe2100 Quick Manual English v3.0 Page | 51
M-Bus baud rate 300, 2400 Bit/s
TransparentM-Bus
Listeningserver onTCP andGSM data
-
Maximumconnected M-Bus slaves
8 - Can be extended usingCMeX10 Series
Maximum cablelength
1000 m
IR Interface Yes -Pass Through No -
Compatibility All standardM-Busmeters, allABB meters
with IR
interface,C
8/9/2019 Cme2100 Quick Manual English v.3.0 0
52/59
Page | 52 Support: +46 300 434300 [email protected]
CMeXSeriesproducts
General
Data storage ~1.4 MByte Data storage for meterdata and custom reportconfiguration
Real time clockBackup
12 h Number of hours realtime clock resumesrunning without power
Real time clockAccuracy
8/9/2019 Cme2100 Quick Manual English v.3.0 0
53/59
CMe2100 Quick Manual English v3.0 Page | 53
Software update UsingGSM/GPRS/ HTTP
-
Integration
Transparent M-Bus static IP
TCP
Transparent M-Bus
GSMCSD/raw M-Bus data
E-mail SMTPFTP Standard
FTP clientHTTP Standard
HTTP andHTTPS
client, POST
& GET
8/9/2019 Cme2100 Quick Manual English v.3.0 0
54/59
Page | 54 Support: +46 300 434300 [email protected]
Configuration SMS, HTTP,FTP, GSMCSD, Telnet
Approvals
EMC EN 61000-6-2, EN 61000-6-3
Safety EN 61010-1,
CAT IV
15 Safety and environment
8/9/2019 Cme2100 Quick Manual English v.3.0 0
55/59
CMe2100 Quick Manual English v3.0 Page | 55
y
The following safety precautions must be observed during all phases ofthe operation, usage, service or repair of any CMe2100 product. Users of
the product are advised to convey the following safety information tousers and operating personnel and to incorporate these guidelines intoall manuals supplied with the product. Failure to comply with theseprecautions violates safety standards of design, manufacture andintended use of the product. Elvaco AB assumes no liability forcustomer’s failure to comply with these precautions.
When in a hospital or other health care facility, observe the restrictionson the use of mobiles. Switch the product off, if instructed to do so bythe guidelines posted in sensitive areas. Medical equipment may besensitive to RF energy.
The operation of cardiac pacemakers, other implanted medicali t a d h a i aid a b aff t d b i t f f ll l
8/9/2019 Cme2100 Quick Manual English v.3.0 0
56/59
Page | 56 Support: +46 300 434300 [email protected]
equipment and hearing aids can be affected by interference from cellulterminals or mobiles placed close to the product. If in doubt aboutpotential danger, contact the physician or the manufacturer of theproduct to verify that the equipment is properly shielded. Pacemakerpatients are advised to keep the product away from the pacemaker,while it is on.
Switch off the product before boarding an aircraft. Make sure it cannotbe switched on inadvertently. The operation of wireless appliances in aaircraft is forbidden to prevent interference with communication
systems. Failure to observe these instructions may lead to the suspensioor denial of cellular services to the offender, legal action, or both.
Do not operate the product in the presence of flammable gases orfumes. Switch off the product when you are near petrol stations, fueldepots, chemical plants or where blasting operations are in progress.
Operation of any electrical equipment in potentially explosiveatmospheres can constitute a safety hazard
8/9/2019 Cme2100 Quick Manual English v.3.0 0
57/59
CMe2100 Quick Manual English v3.0 Page | 57
atmospheres can constitute a safety hazard.
Your product receives and transmits radio frequency energy whileswitched on. Remember that interference can occur if it is used close to
TV sets, radios, computers or inadequately shielded equipment. Followany special regulations and always switch off the product whereverforbidden, or when you suspect that it may cause interference ordanger.
IMPORTANT
CMe2100 operates using radio signals and cellular networks. Because ofthis, connection cannot be guaranteed at all times under all conditions.Therefore, you should never rely solely upon any wireless product foressential communications, for example emergency information.
16 Accessories and similar products
8/9/2019 Cme2100 Quick Manual English v.3.0 0
58/59
Page | 58 Support: +46 300 434300 [email protected]
p
Elvaco provides a complete product range to meet various demands.Accessories:
Product Description
ExternalAntenna
External antenna to increase GSM signal strength
CMeX10 M-Bus master – Connect up to 32 M-Bus slaves
CMeX20 M-Bus activator – Enable standard M-Buscommunication to ABB electricity meters with IRinterface
CMeX30 M-Bus D/A module – Steer 0 to 10 V or 0 to 20 mAoutput
CMeX40 M-Bus I/O module – Input/output to peripheral devices
CMa10 M-Bus temperature and humidity sensor for indoor usewith display
CMa11 M-Bus temperature and humidity sensor for indoor usewithout display
8/9/2019 Cme2100 Quick Manual English v.3.0 0
59/59
CMe2100 Quick Manual English v3.0 Page | 59
without displayCMa20 M-Bus temperature and humidity sensor for outdoor
useM-Bus Splitter Share one to four M-Bus meter between two M-Bus
mastersSimilar products:
Product Description
CMi2110 GPRS M-Bus communication module integrated inLandis+Gyr UH50 meter and 8 M-Bus slaves
CMi2120 GPRS M-Bus communication module integrated inLandis+Gyr E350 meter and 8 M-Bus slavesCMi2130 GPRS M-Bus communication module integrated in Itron
ECHO II / CF meters and 8 M-Bus slavesCMe3000 TCP/IP M-Bus communication module for ABB
electricity meters with IR interface and 8 M-Bus slaves