IntroductionColorless and Directionless ROADM architectures PXC based architecture WSS based architecture
Colorless, Directionless and Contentionless ROADMarchitecturePractical Implementation IssuesConclusion
8/8/2019 Colorless Devarajan
3/30
Rich MediaServices
Triple PlayServices
BusinessServices
US HQ
India
ScientificResearch
CERN
8/8/2019 Colorless Devarajan
4/30
Challenges :Services are unpredictable in terms of their bandwidth, routing patternsand requirements.Provisioning high bandwidth connectivity to every single site.Expectations - access to all the contents on demand, at any time and from
anywhere.In this unpredictable business environment, deliver all the services, asquickly as possible.
Solutions:Next gen agile optical network reconfigurable and scalable optical layerROADMs Reconfigurable Optical Add/Drop Multiplexers.Colorless and Directionless architecture.
8/8/2019 Colorless Devarajan
5/30
In ROADM-driven optical systems, the flexibility of the mesh networkcan be extended by Colorless and Directionless (C&D) feature at everynode in the network
Colorless feature at a local add/drop port - ability of tunabletransponders to have wavelength transparent access to all the DWDM
network portsDirectionless feature at a local add/drop port - ability of tunabletransponders to have non-blocking access to all the DWDM networkports
C&D feature enables efficient use of all the tunable access resources for
on-demand and high bandwidth network configuration and simplify thenetwork architecture
8/8/2019 Colorless Devarajan
6/30
At a 4 degree node, the architecture consists of:320x320 non-blocking 3D MEMS large optical switches at the coreof PXCA set of AWG based 40 channel Mux/DemuxsTunable transponders at local add/drop ports
PXC based C&D architecture
Sample mesh optical network
8/8/2019 Colorless Devarajan
7/30
AdvantagesProvides Colorless and Directionless featureProvides Contentionless feature - same wavelengths carrying differentinformation can be received/sent simultaneously with the help of multipletunable transponders from/to different input/output fiber portsEfficient utilization of wavelengths
Provides 100% add/drop at the local portsMinimal loss
ConcernsAs the number of ports N, in NxN core switch grows the number of possible connections increases as N 2
Does not support multicasting can not drop a wavelength from adirection while simultaneously sending the same wavelength to otherdirections along the express path Core switching fabric acts as a single point of failure
8/8/2019 Colorless Devarajan
8/30
Both the cores are keptactive to avoidchallenges faced whileswitching the entireservicesProtection Switching Card (PSC) - performsthe functions of a 2x1Protection Switch (PS)and also a passivesplitter (S)
Protection is providedper transponder basis
Protection Scheme employed with dual core switching matrix inPXC based architecture
8/8/2019 Colorless Devarajan
9/30
1
2
3
4
40
Port 1 Port 2 Port 3 Port NPort 4
VOA
8/8/2019 Colorless Devarajan
10/30
1
2
3
4
40
Port 1 Port 2 Port 3 Port NPort 4
VOA
8/8/2019 Colorless Devarajan
11/30
The architecture
consists of: 1x9 WSS modules Multi-port splitter
combiners (S/C)
S/C at the localadd/drop siteprovides expansionfacility.
WSS along eachdirection can eitherblock or allow acertain wavelength.
WSS is a betterchoice along eachdirection as it offersintelligentfunctionalities than apassive combiner.
8/8/2019 Colorless Devarajan
12/30
Advantages:Provides Colorless and Directionless feature at the local add/drop siteWSS can provide Dynamic Channel Equalization and hence maximizesoverall performanceAny wavelength from any direction or originating at that node can bemulticast to all the directions
Offers Pay-as-you-grow approach allows modular growth Scalable in terms of bothnode-degree and number of add/drop wavelengths
Number of WSS modulesrequired at the local add/dropsite depends on the numberof ports in it.
8/8/2019 Colorless Devarajan
13/30
Concerns:Very expensive on day 1Does not provide contentionless add/drop
Consider 2 differentservices on samewavelength with commonend point no contention
If another service on samewavelength to the sameend point contention
Contention can be avoidedwith multiple WSS & S/Cmodules, but expensive
8/8/2019 Colorless Devarajan
14/30
CD&C architecture is realized by combining the WSS basedROADMs with PXCThe WSS modules and multi-port splitter combiners are replacedby PXC in the WSS based C&D architecture
CD&C architecture
consists of: WSS modules Multi-port splitter
combiners 320x320 non
blocking 3D MEMSbased PXC
8/8/2019 Colorless Devarajan
15/30
Provides all the features offered by both PXC based and WSS basedarchitectures
PXC used for the local add/drop provides the Contentionlessadd/drop access in addition to C&D feature
Allows modular growth in number of transponders depending onnumber of add/drop wavelengths at the local add/drop site
Better wavelength utilization
Minimal optical power loss compared to WSS based architecture
Completely eliminates the need for a number of WSS modules andsplitter combiners at the local add/drop site Minimum CAPEX
8/8/2019 Colorless Devarajan
16/30
Performance analysis
Choice of sub-system technologies
Cost considerationsOther challenges
8/8/2019 Colorless Devarajan
17/30
Power budgeting and OSNR calculationDistances between the nodes in the sample mesh network -80km
Launch power of a 10Gbps tunable transponder : 1.5dBm - PXC based C&D architecture 4.5dBm - WSS based C&D architecture 4.0dBm - CD&C architecture
Minimum permissible value of the power level, at the APD
receiver is -26dBm
8/8/2019 Colorless Devarajan
18/30
Every wavelength from a local add site must pass through: Protection Switch Card, PSC ( 3.5dB loss ) 320x320 MEMS switching core ( 2.5dB loss ) 40 channel Mux ( 4dB loss ) Protection Switch PS ( 3.5dB loss )
Every wavelength along the pass-through channels are sent via: 1x2 power splitter ( 3dB loss ) 40 channel Demux ( 4dB loss ) 320x320 MEMS switching core ( 2.5dB loss ) 40 channel Mux ( 4dB loss ) Protection Switch ( 3.5dB loss )
Every wavelength that is to be dropped must pass through: 1x2 power splitter( 3dB loss ) 40 channel Demux ( 4dB loss ) 320x320 MEMS switching core ( 2.5dB loss ) Protection switch ( 3.5dB loss )
Fiber loss for each fiber link of 80km
Total loss of 13.5dB
Total loss of 17.0dB
Total loss of 13.0dB
20.0dB (loss of 0.25dB/km )
8/8/2019 Colorless Devarajan
19/30
Every wavelength from a local add site must pass through:
Protection switching card, PSC ( 3.5dB loss ) Two WSS modules ( 6dB loss each ) Two 1x8 power splitters ( 9dB loss each )
Every wavelength along the pass-through channels are sent via: 1x8 power splitter ( 9dB loss ) WSS module ( 6dB loss )
Every wavelength that is to be dropped must pass through: Two 1x8 power splitters ( 9dB loss each ) Two WSS modules ( 6dB each ) Protection switching card ( 3.5dB loss )
Fiber loss for each fiber link of 80km
Total loss of 33.5dB
Total loss of 15.0dB
Total loss of 33.5dB
20.0dB (loss of 0.25dB/km )
8/8/2019 Colorless Devarajan
20/30
Every wavelength from a local add site must pass through: Protection Switch Card, PSC ( 3.5dB loss ) 320x320 MEMS switching core ( 2.5dB loss ) 40 channel Mux ( 4dB loss ) Protection Switch PS ( 3.5dB loss ) WSS module ( 6dB loss )
Every wavelength along the pass-through channels are sent via: 1x8 power splitter ( 9dB loss ) WSS module ( 6dB loss )
Every wavelength that is to be dropped must pass through: 1x2 power splitter ( 3dB loss ) 1x8 power splitter ( 9dB loss ) 40 channel Demux ( 4dB loss ) 320x320 MEMS switching core ( 2.5dB loss ) Protection switch ( 3.5dB loss )
Fiber loss for each fiber link of 80km
Total loss of 19.5dB
Total loss of 15.0dB
Total loss of 22.0dB
20.0dB (loss of 0.25dB/km )
8/8/2019 Colorless Devarajan
21/30
Launch power of a 10Gbps tunabletransponder : 1.5dBm for the case of PXC based C&D
architecture 4.5dBm for the case of WSS based C&D
architecture 4.0dBm for the case of CD&C architecture
Each channel suffers a specific loss
EDFAs at various locations provide therequired amplification to keep opticalpower level within the limits
8/8/2019 Colorless Devarajan
22/30
24dB 13dB
18dB
18dB18dB
12dB
20dB 16dB EDFAs are associated with specific noisefigures (NF) which vary with amplificationvalues
8/8/2019 Colorless Devarajan
23/30
NF = Noise figure of the amplifier h = Plancks constant = 6.634 x 10 -34
f = bandwidth that measures the NF= 0.5nm (62.08GHz)
= optical frequency = 193 THz
CD&C architecture has better OSNRperformance
CD&C ROADM architecture could alsobe 40Gbps ready as it readily providesthe 6dB higher OSNR margin
1
1OSNRprevious_stage +
NF h f Pi/p_current_stage(Watts)
OSNRcurent_stage=
OSNR values at amplifiers along a chosen path
8/8/2019 Colorless Devarajan
24/30
Plays important roll in the performance of architectureLiquid crystal based switches - stable but slight defect introducesa high power lossBubble based switches high switching speed but lesser coresizeThermo optical waveguides faster switching but constantheating and cooling causes adverse on the deviceMEMS based switches requires vibration free environment butprovides high i/p & o/p port counts, minimal loss, low PDL
8/8/2019 Colorless Devarajan
25/30
In PXC based & WSS based architectures, cost of implementation isvery expensive
CD&C architecture - relatively lower CAPEXThe overall cost of architecture at a node is calculated by: cost of the devices cost based on number of ports used for a particular add/drop ratio
No. of ports used = (No. of degrees) x (No. of channels per degree) x 2 +(Add/drop ratio) x (No. of d egrees) x (No. of channels per degree) x 2
For PXC based architecture: $ 200 per PXC port
$ 3,000 for a pair of AWG based Mux/DemuxsFor WSS based architecture: $ 9,000 for a 1x9 WSS module
The same costs were considered for CD&C architecture
8/8/2019 Colorless Devarajan
26/30
At lower add/dropratio, PXC basedarchitecture is veryexpensiveWSS based architecturebecomes expensive asmore no. of wavelengthsadded/droppedAs the add/drop ratioincreases, the CD&Carchitecture is very costeffective
8/8/2019 Colorless Devarajan
27/30
Complex interconnections between core switches andMux/Demuxs or other components
Integrating core switches with other components reduces complexity, power requirement and space
occupiedHowever, it has the drawback of making it a single-vendor solution
Scalability beyond 8 degrees and 40 channels
8/8/2019 Colorless Devarajan
28/30
Colorless, Directionless and Contentionless ROADM architectureenabled by the combination of WSS based ROADM and PXC is
proposedPractical implementation issues of CD&C architecture werediscussedCD&C provides
contentionless add/drop along with Colorless and Directionless features dynamic optimization of lightpaths by optical bridge-and-roll elimination of wavelength conversion alternate protection paths
CD&C architecture is a promising solution: Flexibility Ease of provisioning Modular add/drop Minimal pre-planning