R.A.S.E.R. vs. Shipping ContainerProduct Overview
•4 RASER High Density Zone•Water Cooled RASER deployment 1680 Blade Servers in 40’ x 5.5’•50 Air Cooled 600 KVA IT Load Data Center Build•50 Water Cooled 825 KVA IT Load Data Center Build
Elliptical Mobile SolutionsElliptical Mobile Solutions, LLC is an Arizona Limited Liability Company that has invested over 4 years in the development of its Green Mobile Data Center products.EMS has 2 patents issued, 2 patents with “Notice of Allowance” granted on all claims and has another 5 pending applications filed with the US Patent and Trademark Office. EMS has also filed for international patents for the same inventions in India, China, EP, Canada and South Korea.
EMS is Green IT and Next Generation Technology.
Current Partners
EMS CURRENT PRODUCTSS.P.E.A.R. : Half Height, Hardened, Air Tight, Water Tight, Shielded IT Mobile Enclosure / Data Center
R.A.S.E.R. : Full Height, Sealed Enclosure
• Up To 50% $ Savings on Electricity• Patented zero bypass cooling system• 50-80% More efficient = Green
• Up To 75% Floor Area Savings• 25 ft² for EMS enclosures vs. 100 ft² traditional raised floor
• Fireproof and Water Proof• Air Tight Closed Loop System
• Eliminates Shock and Vibration Damage• Patented Equipment Suspension
• Scalable from 1 Micro Data Center to 100’s; “Pay as You Need”• Purchase cooling, security, fireproofing, raised floor, hot and cold isle
• Customer Validated• Customer “Trial Success” and First Purchase Order Received
C-S.P.E.A.R.: Lightweight, Self Contained Half Height Mobile Enclosure
3Copyright Elliptical Mobile Solutions 2009 www.ellipticalmobilesolutions.com
R.A.S.E.R.™is available in several different configurations• 12KW Self Contained• 16.5KW (Water cooled) Self Contained• 20KW on Product Roadmap
Includes the following:Keyed Lock System• 42,000 BTU single or double rear door mounted air conditioner• Patch Panel/switch side car• Basic suspension system for shock/vibration isolation
Optional Upgrades:• Cyberlock Security Key System and software• Aerogel fireproof insulation • Interior Lighting• Extreme Seismic/ Shock and Vibration Control• N+1 Venting
Physical Characteristics:Rail to Rail Depth: 36”Total Cabinet Depth: 43”Overall Dimensions: Air Cooled - 36 + (6U side car) *30” W X 82” H X 80” DWater Cooled - 36 + (6U side car) *30” W X 82” H X 66” D(Side Car) is for 6U of low density equipment mounted vertically Air Cooled 42U - *24” W X 96” H X 80” DWater Cooled 42U - *24” W X 96” H X 66” DWeight: Air Cooled 550LBS Water Cooled: 400 LBS10g Powder Coated Steel Construction
Blades/Servers
StorageNetwork
and Monitoring
Storage/
Blades/Server
36U+6U “sidecar” for network/management
42U
7 U14 Blades
7 U14 Blades
7 U14 Blades
7 U14 Blades
7 U14 Blades
7 U14 Blades
Two Versions 36+6U RASER and 42U RASER
30” 24”
RASER Front
RASER Front
Example Equipment Type
83” 96”
16.5 KW Water Cooled R.A.S.E.R.
6 Super Micro Super Blade 5500 Blade Chassis 84 Dual Core Blade Servers inside 1 R.A.S.E.R. Self Contained Data Center.
• 6 DataCenter Blades• Dual-Core Intel® Xeon® DP• 84 Server blades• High Efficiency N+1 redundant
power supplies (100~240VAC Option)
Highest Performance per Watt (353 GFLOPS/KW)84 Blade Severs per Enclosure
84 Blade Severs( 336 Cores) 60 Blade Servers (1440 Cores)
• 6 SuperBlade Dual Socket• Quad-Core Intel® Xeon® 5500• 60 Server blades• High Efficiency N+1 redundant
power supplies (100~240VAC Option)
Air Loop 1
Cold Air
Cold
Aisle
Hot Aisl
e
ZERO BYPASS Air Loop 2
Equipment
Equipment
Equipment
Equipment
Equipment
Equipment
Traditional Hot/Cold open aisle Not efficient at high density
Complete Hot And Cold Aisle Containment and Mclean Cooling Technology
Heat removed of data center
floor
Mclean Cooling Technology: Manufacturing mission critical facility cooling for 30 years
“Compressors have a failure rate of 2197 failures/billion hours or an MTBF of 455,166 hours/failure (52.0 years).The blower failure rate is 500 failures/billion hours or an MTBF of 2,000,000 hours/failure (228.3 years).”-Mclean Cooling Technologies
ALL EMS PRODUCTS ENCLOSE THE HOT AND COLD AISLE; REDUCING POWER REQUIRED TO COOL BY 50%
16.5 KW Water12 KW Air
R.A.S.E.R. has three main componentsR.A.S.E.R. Sidecar6U low density space4 power and data pathways
R.A.S.E.R. 36U of high density blade ready space (42U version without sidecar is available)
3 Ton (42,000 BTU) air cooled Heat rejection system16.5KW water cooled available
Standard 19” rack form factor with patented equipment level air delivery
Remove heat through ceiling plenum, flex duct, or room exhaust fan
Switches, KVM Infiniband extender, communications router, CSU/DSU, VIOP
Ambient air in (ducting possible)Or water from chiller
4 Blade Chassis56 Blades448 Cores240 TB Storage
48KW 1.5 PUE Air Cooled High Density Zone
Virtualization, Automated Failover
Blades/Servers
StorageNetwork
and Monitoring
4 Blade Chassis56 Blades448 Cores240 TB Storage
4 Blade Chassis56 Blades448 Cores240 TB Storage
4 Blade Chassis56 Blades448 Cores240 TB Storage
20 16.5KW RASERVendor Neutral 840 RU’sSpace for 1680 Blade SeversCost: $1,200,000Water: 1200W/ft ² design (Not including chillers)Air: 1090W/ft² (including cooling plant)
40’
8’ 5’6”
40” ISO Shipping Container
Width Comparison
330KW 1.2 PUE High Density Zone via 20 Water Cooled R.A.S.E.R.s
20 R.A.S.E.R units
Proprietary and Confidential
Elliptical Mobile Solutions 2009
240KW 1.5 PUE High Density Zone via 20 Air Cooled R.A.S.E.R.sChoose Water or Air Cooled
(Air Cooled 6’7”)
Other Benefits• Can be installed in
traditional building, does not need warehouse (dock door access for install)
• Equipment easily accessed from front and rear of RASER
65. ft
65.2 ft
Offices/Support Equipment
EMS WAY
600KVA IT load12KW RASER
RASER Area
2300ft²50 x $68,000 RASER=$3,400,000 Standardized Modular Compute Space
RASER• Physical Security• Electronic Security• Fireproofing• Watertight
50 X• Energy Efficient• Easy to Expand• Easy to Relocate• Site Management in
Warranty• Scalable• Modular• “Pay as You Go”
RASER Based Data Center2300ft² computer floor
2000ft² office Space
$6,330/KW capacity Build Cost
600 KVA of IT computing capacity with Air Cooled R.A.S.E.R.
The Datacenter as a Computer An Introduction to the Design of Warehouse-Scale Machines 2009 Luiz André Barroso and Urs Hölzle Google, Inc
Competitive Assessment vs. Shipping Container Modular Data CentersEMS “20” Microsoft IBM Sun Rackable HP
Solution 1 R.A.S.E.R. 20 R.A.S.E.R. Shipping container
Shipping container
Shipping container
Semi tractor trailer
Shipping Container
Size(l,w,h)
66” x 24” 83”14 ft²
Shipping Container Footprint
40’ x 7.6 x8’20’ x 8’ x 8.6’
160 ft²40’ x 8’ x 8.6’
320 ft²20’ x 8’ x 8.6’
160 ft²(without
water chiller)
40’ x i8’ x 9.6’320 ft²
(without water chiller)
40’ x 8’ x 8.6’360 ft²
(not including water chiller
Capacity 36+6 RUor 42RU 840RU 1000RU 1000RU 240RU 1400 RU 1100RU
IT load (KVA)
12 KVA Air Cooled
16.5 KVA Water 330 KVA NA NA 200 KVA NA 590KVA
Mobility
1 person + pallet jackThrough Doorway
1 person+ pallet jack Through
Doorway
4 vehicle operators plus
technicians Truck & crane
4 vehicle operators plus
technicians Truck & crane
4 vehicle operators plus
technicians Truck & crane
1 vehicle operator plus technicians
Tractor trailer
4 vehicle operators plus
technicians Truck & crane
FeaturesLead time 6-8 Weeks Air OR Water Cooled
Lead Time 8 weeksWater Cooled
12-18 weeksWater Cooled
12-18 weeksWater Cooled 12-14 weeks
Water Cooled12-24 weeks
Water Cooled6-12 weeks
Water Cooled
Vendor Neutral Vendor NeutralProprietary Equipment
Vendor
Proprietary Equipment
Vendor
Proprietary Equipment
Vendor
Proprietary Equipment
VendorVendor Neutral
CostList ±$68k
Cost Per KW: $4121/KW
List: ±$ 1.2MCost Per KW:
$3636/KW
±$1M (internal Use
Only)
±$3M Including Servers
±$860KCost per KW:
$4300/KW
±$3.4M Including
ServersN/A
13
Uptime Institute White Paper
14Elliptical Mobile Solutions®, LLC 2009
“the cost of building a new facility is approaching $2,500 a square foot.” Dan Golding, Vice president and research director of Tier1 Research. April 2009
60 ft
70 ft
Offices/Support Equipment
Raised Floor (Racks/HVAC/Servers)
4,200 ft² x $2,500=$10,500,000
STATE OF THE ART “TRADITIONAL
WAY”
840KW Compute14KW/Rack200W/ft² Design
High Security Area
Elliptical Mobile Solutions®, LLC 2009
• Broken System• Custom• Long Lead Time• Inflexible• Requires
remodel every five years
840KW HPC High Performance Computing Data Center Application Brief
$12,500/KW capacity Build Cost
15
60 ft
60 ft
Offices/Support Equipment
EMS WAY
825KW Compute16.5 KW R.A.S.E.R.708W/ft² Design
R.A.S.E.R. Area
3600ft² x $300 = $1,080,000 Building50 x $60,000 R.A.S.E.R.=$3,000,000$4,080,000 Standardized Modular Compute Space
R.A.S.E.R.• Physical Security• Electronic Security• Fireproofing• Watertight
50 X• Energy Efficient• Easy to Expand• Easy to Relocate• Site Management in
Warranty• Scalable• Modular• “Pay as You Go”
63% SAVINGS FOR SAME COMPUTER POWER
Elliptical Mobile Solutions®, LLC 2009
Data Centers using R.A.S.E.R.
$4,945/KW capacity Build Cost
16
HPC
Summary of HPC Data Center CapEx vs. EMS R.A.S.E.R.®• Broken System• Custom• Long Lead Time• Inflexible• Requires remodel/retrofit every five years
• Energy Efficient• Easy to Expand• Easy to Relocate• Site Management in
Warranty• Scalable• Modular• “Pay as You Go”
3600ft² x $300 = $1,080,000 Building 50 x $68,000 R.A.S.E.R.= $3,000,000Total CapEx = $4,080,000 825KW Standardized Modular Compute Space
4,200ft² x $150 = $630,000 Foundation Building Shell Computer Racks, Fireproofing, HVAC, Security, Air Handling, Raised Floor= $9,870,000Total CapEx = $10,500,000 840KW Custom built traditional raised floor
54% CAPITAL EXPENDITURE SAVINGS FOR SAME SERVER, STORAGE, NETWORK CAPACITY
17
Elliptical Mobile Solutions®, LLC 2009
New Build vs. Retrofit?Elliptical Mobile Solutions products provide the function of the building on the enclosure. They required only a basic building shell. This drastically reduces the cost to build an equivalent data center. A perfect example of this is the retrofit comparison. An additional $500K would provide a new building for a RASER based data center as opposed to a 5 million dollar building with an additional 6 million dollar retrofit.
EMS New Build with Air Cooled RASER• “Requires” $500K Building
• 90 Day Build Time- $60,000 interest during construction
• $400K Labor Savings• One floor• No Raised Floor• 50 RASERS (12KW)• 4,300ft²• Use 9 of 10 Watts purchased for HVAC/
Air Handling• Total Cost 6,798,152
• Requires $5,000,000+ Building• 24 Month Build Time
- $1,000,000 interest during construction• 600K+ Labor• 3 Floors• Raised Floor• 100 Rack Enclosures (6KW)• 10,500ft²• Use 1 of 3 Watts purchased for HVAC/Air
Handling• Total Cost $11,874,074
Traditional New Build
Proprietary and Confidential Elliptical Mobile Solutions 2009
Streamlined Implementation• Rapid Deployment: Rollout in 2 months or less• Standardized Equipment Package• Portable Independent Asset• Avoid Complex Project Management of Build Out• Perfectly Scalable Solution
Other Benefits