+ All Categories
Home > Documents > Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase...

Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase...

Date post: 15-May-2018
Category:
Upload: lammien
View: 339 times
Download: 13 times
Share this document with a friend
25
Compresor lg de 12000 BTU modelo QK173KAG
Transcript
Page 1: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

Compresor lg de 12000 BTU modelo QK173KAG

Page 2: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

Compresor lg de 12000 BTU modelo QK173KAG

Page 3: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

DataRev. No

Rev. description Write

0.Revision History

2 / 13

Ref. No. LGETA-140113-1572

Issued Date 2014.01.13

Rev. No. Rev. 0

Rev. Date -

Page 4: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

1.Specification

1.1 Compressor

1.2 Motor

1 Model Name QK173KAG

2 Compressor Type Hermetic Motor Compressor

3 Compression Type Rotary Type (Rolling Piston Type)

4 Application Refrigeration system (Cooling & Heating)

5 Refrigerant R22

6 Safety Approval -

7 Oil / Oil Charging Amount SUNISO 4GSI or NM56M / 350±5 cc

8 Displacement 17.3 ㎤ / rev

9 Painting Black Color Paint

10 Net Weight ( Including Oil ) 11.9 kg

11 Suction Tube I.D Φ 12.8 mm

12 Discharge Tube I.D Φ8.06 mm

Motor Type / Starting Type Single Phase Induction Motor / PSC

Pole / Rated Output 2 Pole / 940Watts

Power Source 1 Ph - 208/230Volts - 60 Hz

Rated Revolution 3435 rpm

Insulation Class E Class

Windings Resistance

( at 75 ℃ )

Main 3.18 ± 7% Ohms

Sub 5.10 ± 7% Ohms

Locked Rotor Ampere 29 A

3 / 13

Ref. No. LGETA-140113-1572

Issued Date 2014.01.13

Rev. No. Rev. 0

Rev. Date -

+0.150

+0.100

Page 5: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

1.3 Wiring diagram

1.5 Performance

Voltage At 220 V

Cooling Capacity (-5%↑) [ BTU/h ] 12,100

[ W/h ] 3,546

Power Input (+5%↓) [ W ] 1141

EER (-5%↑) [ BTU/Whr ]

[ W / W ]

10.6

3.11

Running Current [ A ] 5.4 A

☞ Rated Conditions (ASHRAE-T Condition)

Cond. Temp. : 54.4 ℃ ( 130 ℉ )Evap. Temp. : 7.2 ℃ ( 45 ℉ )

Return Gas Temp. : 35.0 ℃ ( 95 ℉ )Liquid Temp. : 46.1 ℃ ( 115 ℉ )Ambient Temp. : 35.0 ℃ ( 95 ℉ )

4 / 13

Running Capacitor 25 MFD / 370 VAC

Over Load Protector MRA12074-12027

1.4 Electrical Component

※ Make Sure to connect right way same with the wiring diagram.

Ref. No. LGETA-140113-1572

Issued Date 2014.01.13

Rev. No. Rev. 0

Rev. Date -

Page 6: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

Noise & Vibration Measuring Points

● Measuring points for specification approval- Noise : 2 points ( X , Y )- Vibration : 2 points ( A , B )

● Compressor vibration is measured by a vibration meter which is contacted compressor A ~ B at load condition

● Test Condition : - Standard Condition (Ps/Pd = 5.34 / 20.86 (kgf/cm2G) )(Return Gas: 18.3℃)

Microphone

X

Y300mm

300mm

Microphone

300mm

H/4

H/4

H/4

H/4

H

B

A

1.6 Noise & Vibration

Voltage At 220 V

Sound Level [ dB(A) ] 61 Max

Vibration [ μm/gal ] 130/ 1820 Max

5 / 13

Ref. No. LGETA-140113-1572

Issued Date 2014.01.13

Rev. No. Rev. 0

Rev. Date -

Page 7: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

1.7 Minimum Starting Voltage

Leak Tight PressureHigh Pressure Side 28㎏f / ㎠ G

Low Pressure Side -

Hydrostatic strength

Pressure

High Pressure Side 155 ㎏f / ㎠ G

Low Pressure Side 50.6 ㎏f / ㎠ G

Insulation Resistance

( with 500V D.C Mega Tester )50 ㏁ Min.

Withstand VoltageAt 2,200 V / 1 Sec.

Leakage Current is less than 5 ㎃

Residual Moisture ( Karl Fisher Method ) 60 mg Max.

* Residual Impurities 70 mg Max

Cold Start

- Temp. Condition : 35℃

- Balanced pressure : Pd – Ps ≤ 0.5 ㎏f/㎠176 Volts Max.

at Standard Condition 187 ~ 253 Volts

at Overload Condition 198 ~ 242 Volts

*) Each part was measured separately

1.8 Voltage Range

6 / 13

1.9 Others

☞ Test Conditions

Standard Condition Overload Condition

Con. Temp (℃)

Eva. Temp (℃)

Return Gas. Temp (℃)

Ambient Temp (℃)

54 65

7 13

35 25

35 43

Ref. No. LGETA-140113-1572

Issued Date 2014.01.13

Rev. No. Rev. 0

Rev. Date -

Page 8: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

2.Delivered Parts List

※ ) Refer to Attachments ( Accessory Parts Drawings. )

7 / 13

Parts Name Type ( Model ) EAParts Dwg. NO.

SupplyLG

Compressor QK173KAG 1 - Yes No

OLP MRA12074-12027 1 6750U-L035A Yes No

Cover ,Terminal - 1 3550UTL004A Yes No

Gasket - 1 4986UTL001H Yes No

Nut, Common - 1 1NZZUTL001A Yes No

Washer, Customized - 1 1WZZUTL001A Yes No

Damper, Rubber - 3 4022UTL002B Yes No

Sleeve, Damper - - - Yes No

Bolt, Stud - - - Yes No

Washer, Plain - - - Yes No

Nut, Hexagon - - - Yes No

Ref. No. LGETA-140113-1572

Issued Date 2014.01.13

Rev. No. Rev. 0

Rev. Date -

Page 9: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

3.Operating Limit

8 / 13

Discharge Pressure [ ㎏f / ㎠ G ] 28 Max

Suction Pressure [ ㎏f / ㎠ G ] 2.0 ~ 7.0

Discharge Pipe Temp. [ ℃ ] 115 Max.

Motor Coil Temp. [ ℃ ] 130 Max.

3.1 Operation Range

Area A : Normal Operating Zone

Area B : High Density Flow Zone-Running time less than 3 minutes.

Area C : Low Pressure Zone( defrosting & re-starting )-Running time less than 3 minutes. -Should be checked liquid back

Ref. No. LGETA-140113-1572

Issued Date 2014.01.13

Rev. No. Rev. 0

Rev. Date -

Page 10: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

Refrigerant

Charge Limit

Cooling Only for SRAC system : 550g Max

(Charge limit depends on Oil Dilution Rate *note 1 & accumulator ‘K’)

Liquid

Refrigerant Back

System should be designed not to allow the liquid to go back to

compressor which cause knocking noise , current increase or undesirable

vibration and make short compressor life time.

Δ T :

Temp. Difference

Δ T = Case Bottom Temp.- Condensing Temp.

It must be kept Δ T ≥ 5℃

Pressure

Difference

in Operating

The Pressure difference in operating shall be 5.0㎏f/㎠ or more, but 3

minutes starting excluded.

ON/OFF

OperationEach cycle should be at least 6 minutes

(ON Time : at least 3 minute , OFF Time : at least 3 minutes)

Pressure

Difference

at Starting

When starting, discharge pressure is balanced with suction pressure.

( Pd – Ps ≤ 0.5 ㎏f/㎠ )

Tilt in Operation The allowable tilt of the compressor in operation shall be 5˚ or less.

System

Accumulator

The Accumulator volume should be enough to cover 30% of maximum

system refrigerant volume.

Ratio coefficient ‘K’ should be over 0.6(heating system) or 0.4(cooling

system)

Volume of Accum.(Comp+System) × Specific gravity of RefrigerantK = ----------------------------------------------------------------------

Charged Weight of Refrigerant

※ Effective volume of compressor accumulator = 176 ㎤※ Specific gravity of refrigerant (R22) = 1.25 g/㎤ ( at 20℃ )

If coefficient “K” does not meet recommendation, refrigerant system must check liquid back phenomenon at accumulator.

Protecting

Reverse

Operation

The compressor must be operated by proper voltage in accordance with

the frequency without reverse revolution condition. The reverse

revolution condition can be avoided by just keeping right order of phase

supplied power source.

9 / 13

3.2 Application Limit

Ref. No. LGETA-140113-1572

Issued Date 2014.01.13

Rev. No. Rev. 0

Rev. Date -

※ This guide contains many important safety messages. Always read and obey all safety messages.

You can be killed or seriously injured if you don’t follow instructions.

Page 11: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

* Effective Period of This Document *

This document will be effective after LG’s receipt with your authorized signature.When design modification is approved by the customer, the current document is unavailable.

Frequency Range Rated Frequency ±2%

Pipe Stress Don’t allow any force on discharge & suction pipe .

The piping stress must be less than 300㎏f/㎠ at starting and

stopping. And less than 153㎏f/㎠ at running.

Oil Level It must be checked oil level by the compressor with

sight glass we supply. And oil level must be kept over

guide line level **note 2. at any condition.

Protection device Refrigeration system must has the compressor protection device

like over pressure, high temperature, sensing locked pump in the

controller.

When starting & running fail by abnormal overload, controller

must be able to cut off power of compressor before motor burn

out.

An earth terminal should be installed to prevent electrical

accidents.

Pump down

refrigerant

If pump down time is too long, compressor can be damaged due

to excessive temperature increase or poor lubrication.

Guideline of pump down process.

- Time : less than 30 seconds

- Suction Pressure : It should not run under below 1㎏f/㎠G.

And before closing a service valve, compressor running for more

than 5 minutes is recommended.

10 / 13

※ If gas charge amount of refrigerant specified is exceeded, both parties should discuss the matter to determine compressor specification.(accumulator volume, lubricating oil amount) and system specifications (crank case heater, oil separator , additional accumulator, etc)

3.2 Application Limit

Ref. No. LGETA-140113-1572

Issued Date 2014.01.13

Rev. No. Rev. 0

Rev. Date -

Page 12: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

Use defined Refrigerant

and oil

Any process in where the HCFC’s refrigerant or the

different kind of oil against the defined. Compressor oil are

mixed should be avoided.

Avoid Damage running The running operation that inspection and the protector

inspection that affect a damage to the function and

durability of the compressor should be avoided

Running dummy indoor When the outdoor unit is operated with the indoor dummy

unit, the discharged oil should be recovered enough

Prevent oxidation in pipe Always purge the system and the compressor with the dry

nitrogen in order to prevent oxidation of the piping

Charging Refrigerant When charging refrigerant into the cycle, make sure that

refrigerant always be filled from the higher pressure side

(condenser exit) of the cycle.

If liquid refrigerant is sucked in to the compressor liquid

compression occurs, The discharge valve is damaged,

lubrication effectiveness degenerates and reliability drops

noticeably

Avoid Vacuum running Do not operate the compressor in a vacuum state.

Furthermore do not apply high voltage to a vacuum state

compressor. There is a danger that insulation could

degenerate, causing electric shock

Avoid Air compression Do not compress the air including the case of leakage in the

refrigeration cycle. If compressors run with air mixed,

inside the compressor is heated and pressurized , which

may cause an explosion

Promptly Assemble

compressor in line

After removing rubber plugs from compressor tubes,

Promptly use the compressor. And do not leave in the

atmosphere for 10 minutes over. If Air gets into the

compressor , accelerating degeneration of the inside of the

cycle or compressor

Wiring Wires connected to the compressor, follow the compressor

specification manual and instructions

Storage temperature -10℃ ~ 65℃

11 / 13

3.3 Process Limit

Ref. No. LGETA-140113-1572

Issued Date 2014.01.13

Rev. No. Rev. 0

Rev. Date -

Page 13: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

* Effective Period of This Document *

This document will be effective after LG’s receipt with your authorized signature.When design modification is approved by the customer, the current document is unavailable.

12 / 13

** Note 2. Oil Level Guide Line

* Note 1. OIL Dilution rate

Oil Weight------------------------------------------ ≥ 0.22(Heating) or 0.20(Cooling) Refrigerant Weight + Oil Weight

※ Specific Gravity of NM56 = 0.92 (at 20℃)

[ Unit ]

☞ Oil Weight : [ g ]

☞ Refrigerant Weight : [ g ]

Over Level A : Steady state at any condition.

Over Level B : Minimum level of transition period within 3 minutes.

Level A

Level B

Sight glass

H/2

H/2

SUB BEARING

CYLINDER

MAIN BEARING

Ref. No. LGETA-140113-1572

Issued Date 2014.01.13

Rev. No. Rev. 0

Rev. Date -

Page 14: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

* LABEL *

* Effective Period of This Document *

This document will be effective after LG’s receipt with your authorized signature.When design modification is approved by the customer , the current document isunavailable.

13 / 13

EXPLOSION OR FIRE- Wear safety goggles and gears as systemcontains oil and refrigerant under pressure- Do not compress air.- Do not use refrigerant and lubricants besidesthose specified.

- Make sure to connect right way with valves.

30

45

WARNINGWARNING

ELECTRIC SHOCK HAZARD - Ground the equipment securely.- Turn off the power before servicing.- Retain Terminal Cover in position whenever

power is applied to the compressor.

Service should be performed by trained personnel only .

BURN HAZARD- Do not touch the Compressor with bare hands

during operation or after stoppage instantly.

EXPLOSION OR FIRE- Wear safety goggles and gears as system

contains oil and refrigerant under pressure.- Do not compress air- Do not use refrigerant and lubricants besides

those specified.- Make sure to connect right way with valves.

66

QK173KAGTHERMALLY PROTECTED R22

SERIAL NOX

XX

XX

XX

XX

XX

XX

XX

XX

X

Ref. No. LGETA-140113-1572

Issued Date 2014.01.13

Rev. No. Rev. 0

Rev. Date -

208-230V ~ 60Hz 1PH LRA29

All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed. You are strongly advised to follow these safety instructions.

This is the Safety alert symbol. It indicates a hazardous situation which, if not avoided, could result in death or serious injury.

This is the Electric shock hazard symbol. It indicates a hazardous situation which, if not avoided, could result in the electric shock.

This is the Getting burnt symbol. It indicates a hazardous situation which, if not avoided, could cause fire.

This is the Explosion or Fire symbol. . It indicates a hazardous situation which, if not avoided, could cause explosion or fire.

Page 15: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

Attachment

PAGE

: A-1

: A-2

: A-3 ~ A-8

: A-9

1. Compressor Drawing

2. Accessory Fitting

3. Part Drawings

4. OLP Curve

Page 16: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

2014.01.13

X.L.YANG

A-1

NOTES

1. PAINTING : BLACK PAINT ( ELECTRO DEPOSITION )

2. OIL : SUNISO 4GSI or NM56M 350±5 cc CHARGED

3. NITROGEN CHARGED AFTER DEHYDRATION

4. UNIT : m

m

Ref. No.

Issued date

Rev. No.

Rev. Date

LGETA-140113-1572

2014.01.13

Rev. 0

-

QK173KAG

UNIT

mm

SCALE

N / S

CHF. ENGR.

DES. ENGR.

CUSTOMER

G.C.Alliance

COMP. OUT LINE

2014.01.13

S. M. BYUN

LG Electronics(Tianjin)

Appliance Co.,Ltd

Detail of Suction Tube

Detail of Discharge Tube

A D

eta

ilB

Deta

il

90

93

176

3-19.1

3-

Ø19.1

Ø17

6

93.4±

3

10

0.5

Ф12.8

+0

.15

8.0

6

15.9

18

+0.1

0

BA

Ø5

0.8

Ø1

17

.74

227

223.6

229

2.3

42 20

35

220 33.6

Label P

ositio

n

270°

265.6±3

253.6±3

Page 17: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

A-2

Accessory Fitting

LG Electronics Inc.

Accessory Fitting

○◐

○◐

POWERSUPPLY

RUNNINGCAPACITOR

HERMETICTERMINAL

C

R S

Cover Terminal

R

C

S

(W)

(U)

(V)

C,S,R mark embossed on cover terminal

Gasket

Cover Terminal

Nut, Hexagon Flange

O.L.P

Washer, Plain Cover

Page 18: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

A-3

COLORMATERIAL REMARK

MARKS(C(W),R(U),S(V))BLACKLumax

Cover, Terminal

Drawing No. 3550UTL004A( UNIT : ㎜ )

LG Electronics Inc.

Page 19: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

A-4

1.0

MATERIAL REMARK

MARKS(C(W),R(U),S(V))PRESS RUBBER EPDM

30

43.6

Φ44

Φ12

Φ46

Φ29

Φ30

47.2 S(V)

R(U)

C(W)

Gasket

Drawing No. 4986UTL001H

( UNIT : ㎜ )

LG Electronics Inc.

Page 20: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

5.5

Φ12

8

9.2

* MATERIAL : STEEL ( ELECTRIC PLATING OF ZINC )

Nut, Common

Drawing No. 1NZZUTL001A

( UNIT : ㎜ )

LG Electronics Inc.

A-5

Page 21: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

* MATERIAL : POLYAMIDE ( NYLON )

Washer, Customized

Drawing No. 1WZZUTL001AΦ

5.5

Φ15

1

( UNIT : ㎜ )

LG Electronics Inc.

A-6

Page 22: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

Damper, Rubber

Drawing No. 4022UTL002B

( UNIT : ㎜ )

LG Electronics Inc.

A-7

Page 23: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

A-8

Overload ProtectorDrawing NO. 6750U-L035A

( UNIT : ㎜ )

LG Electronics Inc.

VENDER : Sensata

VENDER PART No. :

SPECIFICATION

1. OPEN TEMP. :

2. CLOSE TEMP. :

3. SHORT TIME TRIP :

4. ULTIMATE TRIP CURRENT :

150±5℃

70±11℃

20.5 Amps.,11±5sec.at 25℃

9.8 Amps. at100℃

MRA12074-12027

0.8

6.4

8.0

7.3

16

QUICK CONNECT BLADE

Φ26.2

Φ24.6

±0.2

±0.2

±0.2

+0.05-0.03

±0.3

±0.3

±0.5

29

.5 以下

3.0±

0.3

1

32

57±

4

Page 24: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

A-9

O.L.P Characteristic Curve

1. EPA : Temperature (℃)

<FIG-1>

EPA = ( A + B ) / 2

A = Temp. of the inner space of Terminal Cover.

B = Temp. of the seat of O.L.P ( the top of compressor )

※ to see FIG-1.

2. Reference (FIG-2)

Section A : O.L.P doesn't work.(Compressor run)

Section B : Uncertain section.

Section C : O.L.P work. (Compressor doesn't run)

* To run compressor, The Amp. & E.P.A must be in section-A.

A

BGasket

Cover Terminal

<FIG-1>

EPA(℃)

Amp.A

BC

<FIG-2>

OPEN TEMP. : 150.00 ± 5.0 ℃ LG P/No.: 6750U-L035A CLOSE TEMP. : 70.00 ± 11.0 ℃ VENDER : Sensata SHORT TIME TRIP: 20.50 Amps.,11±5Sec. at 25℃ VENDER P/No.: MRA12074-12027 ULTIMATE TRIP CURRENT: 9.80 Amps.,at 100.00 ℃

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

66 71 76 81 86 91 96 101 106 111 116 121 126 131

EPA(℃)

Amp.

A

B

C

Page 25: Compresor lg de 12000 BTU modelo QK173KAG - REFECOL · Motor Type / Starting Type Single Phase Induction Motor / PSC ... Compressor QK173KAG 1 ... Protection device Refrigeration

Distribuido por: