Compressed Air DryersHigh efficiency direct expansion dryersfor ultimate performance and reliability
The principles of operationWet compressed air enters thedryer and is directed to the singlemonobloc plate heat exchangers.The air entering is cooled downby the outgoing cold and driedair which reduces the load on therefrigeration compressor, savingenergy costs.The air now passes tothe “air to refrigerant”heat exchangerwhich reduces itstemperature to thepre-set dew point(normally +3°C)where water dropletsform. All thecondensedmoisture isseparated fromthe air in the highefficiency waterseparator whereit is dischargedto a drain.
Finally, the cool and dry air isreheated by thermally mixing itwith the incoming air that alsoreduces its relative humidity, thuspreventing pipework corrosionand annoying condensation onthe downstream pipework.
Water - theessence of life,curse of thepneumaticsindustry!
Why is water so much a
poison to industrial
compressed air users, and
where does it come from?
Water in a compressor
system is simply a
nuisance. It makes things
rust, causes seizures,
washes away lubricant
from air tools, causes
inaccuracies and much
more, resulting in product
wastage inconvenient
malfunctions and costly
downtime.
This water comes from the
air that originally entered
the compressor. Although
it entered as a harmless
vapour, it changes its state
during compression and
aftercooling resulting in
water droplets forming
which in turn causes all
the associated problems.
Installing a Rep Air dryer
within the process will
prevent these costly
diseases by eliminating
almost all of the harmful
water and return only
clean and dry air into the
network which will ensure
the plant can operate
efficiently and reliably with
minimal running costs.
The Rep Air range:
simplicity, efficiency
and reliability using
modern concepts in
air drying
Many refrigerated dryers maylook the same but the new Rep Air range is far from beingjust another dryer. The use of thelatest, and highly efficient,stainless steel plate type heatexchangers, designed into arefined package, results in adryer that has an excellentperformance, is simple tooperate and will keep doing itsjob reliably for many years. All this from such a compactcabinet.
The Rep Air series : small in size but awealth of features
• High performance
• Low running costs
• Reliable in service
• Simple to operate
• Built to last
• Compact design
• Service friendly
• Environmentally friendly
High performanceUsing the latest designs of platecoolers (which are a fifth of the sizeof the old “shell and tube” types forthe same capacity), combined withproven direct expansion refrigerationtechnology, produces a dryer withultra high performance under alloperating conditions.
Low running costsIn order to minimise any additionalload on the air compressor, carefulattention has been paid to reducingpressure losses. This, together withthe use of high efficiency heatexchangers and separators, hasbeen a design priority to ensure lowrunning costs.
Reliable in serviceThe use of a reliable control valve in awell designed refrigeration circuiteliminates any risk of freeze-ups.Additionally, the use of fewersoldered joints or couplings meansthat there is less chance of refrigerantleakage - less service calls!
Simple to operateSimplicity is a key to reliability. The Rep Air range uses proven, easyto read instrumentation – nogimmicks, just what’s needed. Onceconnected to the system dry air isthere at the press of switch.
Built to lastThe dryer is built by dedicatedcraftsmen. The quality standards wefollow to ensure consistent reliabilityare in accordance with ISO 9001.
Compact designCombining the monobloc heatexchanger with a cleverly laid outinterior, has allowed the entire dryerto be shrunk compared toconventional dryers saving valuablefloor space.
Service friendlyJust like the reliability of a domesticrefrigerator, the Rep Air dryer willrequire virtually no maintenance –only routine checks. All serviceableitems are located in convenientpositions.
Environmentally friendlyThe Rep Air dryers use only R134aor R407C refrigerants (CFC free),which fully complies with the latestlegislation.
Reference Conditions
Inlet compressed air pressure: 7 barg
Inlet compressed air temperature: 35ºC @ 100% RH
Ambient air temperature: 25ºC
Minimum pressure dew point (PDP): 3ºC
Pressure - barg 5 6 7 8 9 10 12 14 16
Factor (Pc) 0.96 0.98 1.0 1.04 1.06 1.09 1.13 1.18 1.22
Capacity correction for various operating conditions
Example of dryer selection:Which dryer is required to handle the following worst case conditions?
Maximum compressed air flow of 12 m3/min.
Lowest operating pressure of 10 barg.
Maximum air inlet temperature of 40ºC.
Maximum ambient air temperature of 35ºC.
Corrected Capacity is:
Actual Capacity / (Pc * Ic * Ac). = 12 m3/min / (1.09 * 0.89 * 0.9) = 13.74 m3/min.
Dryer Selection is: H11 for a 3ºC PDP.
General Information • Operating pressure range: 2 to 16 barg
• Maximum inlet air temperature: 55ºC
• Ambient temperature range: 0ºC to 43ºC (47ºC option)
• A full range of high performance oil removal and particle filters are also available to suit each dryer
All specifications and details are subject to change without prior notice.
Rep Air Services Ltd.Unit 23,Monarch WayBelton Road Trading EstateLoughbroughLeicsLE11 5XG
T: 01509 213 452F: 01509 212 102
E: [email protected]: www.rep-air.co.uk
AD007 UK 0604
Rep Air Industries Technical SpecificationsDryer Port Capacity Capacity Capacity SizeModel Size @ 3ºC PDP @ 7ºC PDP @ 10ºC PDP Power L x W x H
BSPF cfm m3/min cfm m3/min cfm m3/min kW kg (mm)
H01 1/2" 25 0.7 28 0.79 32 0.9 0.2 30 512x370x512
H02 1/2" 34 0.96 38 1.08 42 1.2 0.21 31 512x370x512
H03 1/2" 42 1.2 48 1.35 53 1.5 0.24 34 512x370x512
H04 1/2" 57 1.6 64 1.8 71 2 0.29 35 512x370x512
H05 1” 71 2 79 2.25 88 2.5 0.52 50 492x562x797
H06 1” 106 3 119 3.38 134 3.8 0.57 55 492x562x797
H07 1” 159 4.5 179 5.06 198 5.6 0.64 65 492x562x797
H08 1” 230 6.5 256 7.26 286 8.1 1.02 75 492x562x797
H09 2” 318 9 357 10.1 396 11.2 1.30 140 1005x776x908
H10 2” 381 10.8 431 12.2 477 13.5 1.90 150 1005x776x908
H11 2” 547 15.5 614 17.4 685 19.4 2.36 170 1005x776x908
H12 2” 636 18 717 20.3 795 22.5 2.66 180 1005x776x908
H13 2” 795 22.5 893 25.3 992 28.1 3.46 190 1005x776x908
Performances are in accordance with ISO 7183.
Inlet temperature - ºC 30 35 40 45 50 55
Factor (Ic) 1.11 1.0 0.89 0.79 0.7 0.62
Inlet temperature - ºC 25 30 35 40 43
Factor (Ac) 1.0 0.95 0.90 0.85 0.84