OSHA  Federal Occupational Safety and Health Act of 1970 resulted in regulations imposed on employers to comply with safety and health standards. This act was promulgated by the U.S Department of Labor and gives OSHA the authority to:  Investigate  Issue citations / safety orders  Levy penalties / fines  Seek criminal prosecution Confined Space Rescue Level I
23
OHIO RESPONSE SYSTEM Confined Space Rescue Level I Confined Space Rescue Level I Technical References: Mod 3
Transcript
Page 1: Confined Space Rescue Level I Technical References: Mod 3.

OHIO RESPONSE SYSTEM Confined Space Rescue Level I

Confined Space Rescue Level I

Technical References: Mod 3

Page 2: Confined Space Rescue Level I Technical References: Mod 3.

Technical ReferencesAgencies and Standards

OSHA (Occupational Safety and Health Administration) 1910.146: Established October 15, 1993 “Permit Required Confined Spaces”

NIOSH (National Institute for Occupational Health and Safety) First edition 1980, Second Edition 1987 “Criteria for a Recommended Standard – Working in

Confined Spaces” ANSI (American National Standards Institute)

ANSI Z117.1: 1989 “Safety Requirements for Confined Spaces”

Confined Space Rescue Level I

Page 3: Confined Space Rescue Level I Technical References: Mod 3.

Technical ReferencesOSHA

Federal Occupational Safety and Health Act of 1970 resulted in regulations imposed on employers to comply with safety and health standards. This act was promulgated by the U.S Department of Labor and gives OSHA the authority to: Investigate Issue citations / safety orders Levy penalties / fines Seek criminal prosecution

Confined Space Rescue Level I

Page 4: Confined Space Rescue Level I Technical References: Mod 3.

Technical ReferencesOSHA

OSHA guidelines are the framework for NFPA 1006, 1670 and should be utilized as a guideline.

Rescue agencies are not immune from OSHA sanctions and or penalties.

Violation of recommended guidelines per OSHA, NFPA and NIOSH could result in findings of malfeasance / negligence.

Confined Space Rescue Level I

Page 5: Confined Space Rescue Level I Technical References: Mod 3.

Technical References OSHA training requirements in relation to rescue

agencies Agencies must be made aware of confined space

hazards Agencies must receive access to comparable permit

spaces in order to: Develop rescue plans Practice Rescues

Goals Familiarize agencies with potential confined space

rescue sites Reduce potential of unfamiliar confined space

environments in jurisdictionConfined Space Rescue Level I

Page 6: Confined Space Rescue Level I Technical References: Mod 3.

Technical References OSHA requirements for Companies with

confined spaces Identify potential areas for confined space

rescue Apply for and post permits at the confined

space sites Prohibit entry of employees into confined

space areas unless a permit is posted at the entrance and OSHA precautions have been followed.

Confined Space Rescue Level I

Page 7: Confined Space Rescue Level I Technical References: Mod 3.

Technical ReferencesOSHA General Employer Requirements

All permit spaces must have danger signs, or other effective means, to designate confined spaces in the workplace

Employers who determine that employees will not enter permit space must still take effective measures to prevent employees from entering the space

Confined Space Rescue Level I

Page 8: Confined Space Rescue Level I Technical References: Mod 3.

Technical ReferencesOSHA General Employer Requirements

Employers whose employees enter a permit space are required to have a written permit-required confined space program

Employees must identify and evaluate permit space hazards before making entry

Develop and implement procedures/operations/practices directed at safe entry operations Specify acceptable entry conditions Isolate permit space Control atmospheric hazards Establish barriers Verify acceptable conditions throughout the duration of any

authorized entry.

Confined Space Rescue Level I

Page 9: Confined Space Rescue Level I Technical References: Mod 3.

Technical ReferencesOSHA General Employer Requirements

Provide equipment at no cost to employees including the maintenance and ensuring the use of such equipment

Evaluate permit space conditions when entry operations are conducted

Provide at least one attendant outside the permit space for the duration of operations

Designate qualified personnel to execute duties Develop and implement procedures for rescue

and emergency services regarding rescuing entrants from permit spaces

Confined Space Rescue Level I

Page 10: Confined Space Rescue Level I Technical References: Mod 3.

Technical ReferencesOSHA General Employer Requirements

Develop and implement a permit system Develop and implement procedures upon

conclusion of a entry operation Evaluate entry operations Assess permit required confined space

program

Confined Space Rescue Level I

Page 11: Confined Space Rescue Level I Technical References: Mod 3.

Technical References Entry Permits

Must be completed prior to making entry Should be posted at entry portal Document compliance with regulations Must be signed by entry supervisor Authorize entry to the space Duration of permit must not exceed time

required to perform the authorized task

Confined Space Rescue Level I

Page 12: Confined Space Rescue Level I Technical References: Mod 3.

Technical ReferencesENTRY PERMIT CONTENT

Space to be entered Purpose Date Duration Name of entrants Name of attendants Supervisor Hazards

Measures used to: Isolate the space Control / Eliminate

hazards Lock/Out Tag/Out Purging Inerting Ventilation / Flushing

Entry Conditions Atmospheric Readings

Confined Space Rescue Level I

Page 13: Confined Space Rescue Level I Technical References: Mod 3.

Technical ReferencesENTRY PERMIT CONTENT

Rescue / Emergency resources

Communications procedures

Equipment Used PPE Testing

Measures used to: Isolate the space Control / Eliminate

hazards Lock/Out Tag/Out Purging Inerting Ventilation / Flushing

Entry Conditions Atmospheric Readings

Confined Space Rescue Level I

Page 14: Confined Space Rescue Level I Technical References: Mod 3.

Entry ChecklistChecklists are a tool that helps rescuers insure they are systematically approaching the rescue sequence in an effective, compliant, and safe manner.

Confined Space Rescue Level I

Page 15: Confined Space Rescue Level I Technical References: Mod 3.

Technical References Spaces must be

monitored and findings should be cross referenced utilizing NIOSH Guide to Chemical Hazards, facility MSDS sheets, Emergency Response Guidebook or other approved reference guide.

Confined Space Rescue Level I

Page 16: Confined Space Rescue Level I Technical References: Mod 3.

NFPA Rating Summary Health (Blue)

4 Danger May be fatal on short exposure. Specialized protective equipment required

3 Warning Corrosive or toxic. Avoid skin contact or inhalation 2 Warning May be harmful if inhaled or absorbed 1 Caution May be irritating 0 No unusual hazard

Flammability (Red) 4 Danger Flammable gas or extremely flammable liquid 3 Warning Flammable liquid flash point below 100° F 2 Caution Combustible liquid flash point of 100° to 200° F 1 Combustible if heated 0 Not combustible

Reactivity (Yellow) 4 Danger Explosive material at room temperature 3 Danger May be explosive if shocked, heated under confinement or mixed

with water 2 Warning Unstable or may react violently if mixed with water 1 Caution May react if heated or mixed with water but not violently 0 Stable Not reactive when mixed with water

Special Notice Key (White) W Water Reactive Oxy Oxidizing Agent

Confined Space Rescue Level I

Page 17: Confined Space Rescue Level I Technical References: Mod 3.

Facilities or Vehicles transporting or housing chemicals should have MSDS sheets available to identify hazards.

Confined Space Rescue Level I

MSDS Sheet

Page 18: Confined Space Rescue Level I Technical References: Mod 3.

Technical References3 basic sections to the NIOSH Guide

Confined Space Rescue Level I

Alphabetical Chemical Listing

Appendices (Carcinogens, Exposure Limits, Respirator Requirements, Miscellaneous InformationIndices (CAS # Index, DOT ID # Index, Chemical/Synonym/Trade Name Index)

Page 19: Confined Space Rescue Level I Technical References: Mod 3.

Technical References5 basic sections to the ERG

Confined Space Rescue Level I

Placards

Material Listing by 4 Digit ID Number

Alphabetical Listing by Material Name

Material Listing by Guide Number

Table of Initial Isolation and Protective Action Distances

Page 20: Confined Space Rescue Level I Technical References: Mod 3.

Application

Confined Space Rescue Level I

Page 21: Confined Space Rescue Level I Technical References: Mod 3.

Technical References Lethal Dose is expressed as LD50

Single dose that will cause death of 50% of a group of test animals exposed to it by any route other than inhalation

Lethal Concentration is expressed as LC50 Median lethal concentration of a hazardous

material which is the concentration of a material in air that on the basis of laboratory tests (inhalation) is expected to kill 50 % of a group of test animals when administered in a specific time period

Confined Space Rescue Level I

Page 22: Confined Space Rescue Level I Technical References: Mod 3.

Technical References Detection of flammable or toxic

atmospheres. Acceptable levels after ventilation are defined

as 50% of the level of toxic or flammable substance that would constitute a hazardous atmosphere.

Methane 0.5% is considered hazardous, therefore 0.25%

would be the acceptable maximum level. Chlorine

0.5 PPM is considered hazardous, therefore 0.25 PPM would be the acceptable maximum level.

Confined Space Rescue Level I

Page 23: Confined Space Rescue Level I Technical References: Mod 3.

Technical References

Approach Confined Spaces with EXTREME

CAUTION

Confined Space Rescue Level I


Recommended