+ All Categories
Home > Documents > CP TSSPEC 221 Rev 0 Cable fault location machine Cabl… · shall guide operator through...

CP TSSPEC 221 Rev 0 Cable fault location machine Cabl… · shall guide operator through...

Date post: 27-Apr-2020
Category:
Upload: others
View: 5 times
Download: 0 times
Share this document with a friend
19
REFERENCE REV TITLE: SPECIFICATION FOR CABLE FAULT LOCATION MACHINE CP_TSSPEC_221 1 DATE: FEBRUARY 2019 PAGE: 1 OF 20 TABLE OF CONTENTS Page FOREWORD ...................................................................................................................................... 2 INTRODUCTION ................................................................................................................................ 3 1. SCOPE .......................................................................................................................................... 3 2. NORMATIVE REFERENCES ....................................................................................................... 3 3. REQUIREMENTS ......................................................................................................................... 3 4. DESIGN ......................................................................................................................................... 3 4.1 Digital Time Domain Reflectometer (TDR) Set (Pre-Location Unit)…………………………3 4.2 Continuously Variable Surge Generator………………………………………………………..4 4.3 Acoustic and Magnetic pin-pointing set………………………………………………………...5 4.4 Power Supply………………………………………………………………………………………6 4.5 Installation frame…………………………………………………………………………………..6 4.6 Assembling of equipment………………………………………………………………………...6 5. TRAINING ..................................................................................................................................... 7 6. DOCUMENTATION ...................................................................................................................... 7 7. QUALITY MANAGEMENT ............................................................................................................ 7 8. HEALTH AND SAFETY ................................................................................................................ 7 9. ENVIRONMENTAL MANAGEMENT ............................................................................................ 8 ANNEXURE A - BIBLIOGRAPHY ..................................................................................................... 9 ANNEXURE B - REVISION INFORMATION ................................................................................... 10 ANNEXURE C - Item No. 1 – Cable fault location machine......................................................... 11 ANNEXURE D – Stock Items .......................................................................................................... 19
Transcript
Page 1: CP TSSPEC 221 Rev 0 Cable fault location machine Cabl… · shall guide operator through step-by-step fault locating procedures, 4.1.11 Optimized support of all Arc reflection methods

REFERENCE REV

TITLE: SPECIFICATION FOR CABLE FAULT LOCATION MACHINE

CP_TSSPEC_221 1

DATE: FEBRUARY 2019

PAGE: 1 OF 20

TABLE OF CONTENTS

Page

FOREWORD ...................................................................................................................................... 2

INTRODUCTION ................................................................................................................................ 3

1. SCOPE .......................................................................................................................................... 3

2. NORMATIVE REFERENCES ....................................................................................................... 3

3. REQUIREMENTS ......................................................................................................................... 3

4. DESIGN ......................................................................................................................................... 3

4.1 Digital Time Domain Reflectometer (TDR) Set (Pre-Location Unit)…………………………3

4.2 Continuously Variable Surge Generator………………………………………………………..4

4.3 Acoustic and Magnetic pin-pointing set………………………………………………………...5

4.4 Power Supply………………………………………………………………………………………6

4.5 Installation frame…………………………………………………………………………………..6

4.6 Assembling of equipment………………………………………………………………………...6

5. TRAINING ..................................................................................................................................... 7

6. DOCUMENTATION ...................................................................................................................... 7

7. QUALITY MANAGEMENT ............................................................................................................ 7

8. HEALTH AND SAFETY ................................................................................................................ 7

9. ENVIRONMENTAL MANAGEMENT ............................................................................................ 8

ANNEXURE A - BIBLIOGRAPHY ..................................................................................................... 9

ANNEXURE B - REVISION INFORMATION ................................................................................... 10

ANNEXURE C - Item No. 1 – Cable fault location machine ......................................................... 11

ANNEXURE D – Stock Items .......................................................................................................... 19

Page 2: CP TSSPEC 221 Rev 0 Cable fault location machine Cabl… · shall guide operator through step-by-step fault locating procedures, 4.1.11 Optimized support of all Arc reflection methods

SPECIFICATION FOR CABLE FAULT LOCATION MACHINE

REFERENCE REV

CP_TSSPEC_221 1

PAGE 2 OF 19

FOREWORD

This standard was prepared by the following work group members: H. S. Somo Technology Services R. Mabasa Plant Test The work group was appointed by the Distribution Study Committee, which, at the time of approval, comprised of the following members: Emmanuel Hlatshwayo Secondary Plant Marc Paravano Secondary Plant Patrick o Halloran PCM David Makoni Primary Plant Ledingwana Chidi Network Operations Tshililo Mudzudzanyi Infrastructure Planning Lungi Mzizi Infrastructure Planning Recommendations for corrections, additions or deletions should be addressed to the: Technology Services Manager

City Power Johannesburg (SOC) Ltd

P O Box 38766

Booysens

2016

Page 3: CP TSSPEC 221 Rev 0 Cable fault location machine Cabl… · shall guide operator through step-by-step fault locating procedures, 4.1.11 Optimized support of all Arc reflection methods

SPECIFICATION FOR CABLE FAULT LOCATION MACHINE

REFERENCE REV

CP_TSSPEC_221 1

PAGE 3 OF 19

INTRODUCTION

The cable fault locating equipment is used for testing, pre-locating, and pin-pointing conductor and insulation faults of low and high resistance, intermittent or flashing nature in PVC, PILC and XLPE High Voltage underground power cables.

1. SCOPE

The scope of this specification cover the design, manufacturing, testing, supply, installation, and training of cable fault locating equipment.

2. NORMATIVE REFERENCES

The following documents contain provisions that, through reference in the text, constitute requirements of this specification. At the time of publication, the editions indicated were valid. All standards and specifications are subject to revision, and parties to agreements based on this specification are encouraged to investigate the possibility of applying the most recent editions of the documents listed below.

DIN VDE 0104 (EN50191): Erection and operation of electrical test equipment

DIN VDE 0105 (EN 50110): Operational of electrical installations-Part 100: General requirements

SANS 20055: Uniform provisions concerning the approval of mechanical coupling components of combinations of vehicles

VC 8026: Category o1 and o2 vehicles (caravans and light trailers)

3. REQUIREMENTS

Nothing in this specification shall lessen the obligation of the contractor. The contractor shall be fully responsible for the cable fault location machine, installations and satisfactory performance in service.

4. DESIGN

The system shall operate on 110 to 230 V, 50Hz ±5%, and single phase supply with standalone operation. The system shall be accompanied by easy to use software, which visualizes the recorded data in an understandable way on a PC.

All system components shall be integrated together and there shall be only one control panel with LCD/VGA display for controlling the system above with single button operation. TDR shall be separate and removable from the system to enable the use independently OR with the integrated cable fault locating system. The control of the system shall be easy to operate and should be able to guide the operator in all aspects of cable fault location including Testing, Pre location, Sheath fault location and Pinpointing.

The system shall be suitable for testing (including insulation test), burning and surging for fault conditioning and pinpointing of faults. The system shall be menu driven with single control display with choice of various modes for ease of operation. A central control device, e.g. from the TDR directly will be favoured.

4.1 Digital Time Domain Reflectometer (TDR) Set (Pre-Location Unit)

Pre location unit shall consist of the following features:

4.1.1 Time Domain Reflection Measurement on 3 phases simultaneously,

4.1.2 Arc Reflection Measurement,

Page 4: CP TSSPEC 221 Rev 0 Cable fault location machine Cabl… · shall guide operator through step-by-step fault locating procedures, 4.1.11 Optimized support of all Arc reflection methods

SPECIFICATION FOR CABLE FAULT LOCATION MACHINE

REFERENCE REV

CP_TSSPEC_221 1

PAGE 4 OF 19

4.1.3 Pro-Range technology,

4.1.4 Impulse Current Mode (ICE),

4.1.5 Decay Travelling Wave Method,

4.1.6 Intermittent Fault Location (IFL),

4.1.7 ARM Burning,

4.1.8 Partial Discharge Pinpointing,

4.1.9 Symmetrical / Unsymmetrical reflection measurements,

4.1.10 The pre-location unit shall very convenient to operate with on-line guidance system, which shall guide operator through step-by-step fault locating procedures,

4.1.11 Optimized support of all Arc reflection methods by ΔU Trigger,

4.1.12 Easiest operation by touchscreen and control knob,

4.1.13 Automatic trace analysis with cable end and fault position indication,

4.1.14 Touch Screen colour display,

4.1.15 Compensation: 8 Ω...500 Ω, adjustable,

4.1.16 High resolution by sampling rate of 400 MHz,

4.1.17 Internal compensation for better fault location at short range,

4.1.18 Memory for data storage 8GB,

4.1.19 USB interface for memory stick and printer,

4.1.20 Report generation,

4.1.21 ARM slide - 15 measurement in one ARM shot for selection of best trace,

4.1.22 Automatic storage of all measurements,

4.1.23 Professional range adjustment for optimized display of distant details,

4.1.24 Evaluation of direct measurement on phase, comparison of two phases, and difference of two phases,

4.1.25 An integrated battery, (standby time minimum 4 hours),

4.1.26 Pulse width: 20ns (Nano seconds) range to 10μs (micro second) range.

4.1.27 Measuring range: 20m to 160 km @ v/2 = 80m/μs

4.1.28 IP rating: IP65 closed & IP 54 open.

4.1.29 The TDR can be used as a control unit for the Surge Generator.

4.2 Continuously Variable Surge Generator

The surge generator shall be capable of providing repetitive surges at voltage variable from zero to the required voltage indicated below with an output of 2000 J in each range. It shall be possible to obtain a single shot surge for breaking down the fault for analysis in conjunction with digital fault

Page 5: CP TSSPEC 221 Rev 0 Cable fault location machine Cabl… · shall guide operator through step-by-step fault locating procedures, 4.1.11 Optimized support of all Arc reflection methods

SPECIFICATION FOR CABLE FAULT LOCATION MACHINE

REFERENCE REV

CP_TSSPEC_221 1

PAGE 5 OF 19

locator (TDR). It shall be possible to apply repetitive surge for pin-pointing the faults with the help of pin pointing set.

4.2.1 Integrated insulation measurement at 5kV,

4.2.2 DC testing up to 40kVdc,

4.2.3 Automatically determining breakdown voltage,

4.2.4 Burning 0 to 8kV with 700mA,

4.2.5 Burning 0 to 20kV with 100mA,

4.2.6 Test and locate sheath faults with step voltage of 0 to 5kV and 0 to 10kV,

4.2.7 Pre-Location methods ARM, ICE, Decay & IFL,

4.2.8 Remote control panel capabilities,

4.2.9 Output voltage 0 to 4kV / 2000J, 0 to 8kV / 2000J, 0 to 16kV 2000J, 0 to 32kV / 2000J,

4.2.10 Single shot / pulse adjustable between 3 - 10 seconds,

4.2.11 Burn current shall be adjustable to a maximum of at least 500 mA at 8 kV in order to facilitate pre conditioning of faults,

4.2.12 Discharge devices shall be part of the system.

NOTE: During HV Testing leakage current shall be auto ranging and the system should be capable of auto shutdown and display of breakdown voltage during testing on control panel.

Operation

All modes including insulation testing, DC testing, breakdown recognition, fault conditioning/burning, surge generator, insulation testing etc. with their individual set-ups shall be selectable and operable from this unit. It shall include checking ground loop resistance, step potential, internal emergency-OFF button, over temperature, over current/voltage shut-off features.

It shall have LCD display of sufficient size with one rotary control button and emergency switch. Display shall guide user through the complete testing and cable fault locating modes and shall also give status information, inputs (to surge generator, DC tester, insulation tester etc. with regard to their individual set-up) and results.

All necessary safety interlocks / safety loops shall be incorporated with warning / error massage. System shall not raise any voltage in case it found wrong with the safety loops / interlocks. Storage of the recorded data shall happen automatically to a suitable medium (e.g. USB stick).

4.3 Acoustic and Magnetic pin-pointing set

The portable pin pointing instrument shall consist of a receiver and combined sensor which shall measure electromagnetic and acoustic signals associated with flashovers in cables. The instrument shall pinpoint the fault with direction when used in conjunction with surge generator by combination of acoustic and magnetic signal. The set shall be portable and battery operated with colour LCD display facility to indicate various parameters. Fault location by the magnetic field and sound signal fluke method with the following capabilities:

4.3.1 Consisting of a receiver and ground sensor with accessories, headphones, connection cables

and transport box or mountings,

4.3.2 High acoustic and magnetic field sensitivity,

4.3.3 High performance electronic suppression of external noise and interference,

4.3.4 Excellent acoustic characteristics (frequency range 100 Hz to 1.5 kHz),

4.3.5 Active ear protection by a 85 dB limiter,

4.3.6 Measurement of magnetic field and sound coincidence with automatic selection and calibration of the measuring range,

Page 6: CP TSSPEC 221 Rev 0 Cable fault location machine Cabl… · shall guide operator through step-by-step fault locating procedures, 4.1.11 Optimized support of all Arc reflection methods

SPECIFICATION FOR CABLE FAULT LOCATION MACHINE

REFERENCE REV

CP_TSSPEC_221 1

PAGE 6 OF 19

4.3.7 Automatic contactless turn off of the Headset, as the hand approaches the handle,

4.3.8 Indication of cable position in respect to the sensor,

4.3.9 Indication of the direction to the fault,

4.3.10 Built in adjustable filters for the suppression of interference range 270 Hz - 1,5 kHz,

4.3.11 Colourful display,

4.3.12 Comparison of last and the new measurement on screen,

4.3.13 Graphical indication of the magnetic field,

4.3.14 Peak hold of the magnetic field value,

4.3.15 Indication of the acoustic signal detection,

4.3.16 Indication of all adjustments and settings,

4.3.17 Distance Measurement,

4.3.18 The unit shall have a floating microphone suspension to reduce body sounds of the sensors and provide a solid standing even on sloped surfaces and

4.3.19 The unit shall have a filter setting for Low Pass (100 to 400Hz), Band Pass (150 to 600Hz), and High Pass (200 to 1500Hz).

4.4 Power Supply

A power supply system shall be provided to ensure uninterrupted supply to the equipment during testing with the following requirements:

4.4.1 3kW system,

4.4.2 Integrated inverter,

4.4.3 Integrated charger,

4.4.4 Deep cycle maintenance free batteries and

4.4.5 Strong durable metal enclosure to ensure batteries are kept in safe and stationary position

4.5 Installation frame

The installation shall include a frame/rack with the following requirements:

4.5.1 Silicone HT lead with rated voltage above 50kV,

4.5.2 Earth and Mains lead shall be 50m,

4.5.3 Drums shall have auto braking and anti-roll-off system and

4.5.4 A frame shall an integrated central earth point connected to surge unit to ensure proper earthing

4.6 Assembling of equipment

All equipment and accessories shall be installed in the trailer to ensure a safe and comfortable working experience, meeting the following requirements:

4.6.1 An installation shall include all wiring with DB Board, Separation Transformer, central earth points and a minimum of two additional 3 plug outlets,

4.6.2 Mounted but removable rotating office chair,

4.6.3 Storage shelves for small portable equipment,

Page 7: CP TSSPEC 221 Rev 0 Cable fault location machine Cabl… · shall guide operator through step-by-step fault locating procedures, 4.1.11 Optimized support of all Arc reflection methods

SPECIFICATION FOR CABLE FAULT LOCATION MACHINE

REFERENCE REV

CP_TSSPEC_221 1

PAGE 7 OF 19

4.6.4 A counter top for control units and additional work space,

4.6.5 An installation shall have external orange warning lights system indicating the presence of high voltage or when the system is earthed.

4.6.6 Installation shall include mounting brackets for the ground microphone.

4.6.7 Installation shall include a discharge rod with a resister to ensure soft discharge with a minimum voltage rating of 50kV and

4.6.8 An earthing spike and hammer

5. TRAINING

5.1 The following approved training courses, for City Power’s staff, shall be provided:

5.1.1 Operating, and

5.1.2 Maintenance.

5.2 The associated costs for an approved training course in 5.1 shall be given per person. 5.3 The suppliers shall provide technical support on system and equipment queries for the duration of

the contract.

6. DOCUMENTATION

The following documents shall be provided:

6.1 Technical product catalogue

6.2 operating manual and

6.3 maintenance manuals

6.4 The service provider shall make available all documentation in both hard and soft copy

7. QUALITY MANAGEMENT

A Quality Management Plan/System shall be set up in order to assure the quality of the cable fault location

machine during design, development, production and servicing. Guidance on the requirements for a quality

management system may be found in the following standards: ISO 9001:2015. The details shall be subject to

agreement between the City Power and Supplier/Contractor.

8. HEALTH AND SAFETY

A Health and Safety Plan/System shall be set up in order to ensure proper management and compliance of

the cable fault location machine during installation, operation, maintenance, and decommissioning phase/s.

Guidance on the requirements of a Health and Safety Plan/System may be found in OHSAS 18001:2007

standards. This is to ensure that the asset/service conforms to standard operating procedures and City Power

SHERQ Policy. The details shall be subject to agreement between City Power and the Supplier/Contractor.

Page 8: CP TSSPEC 221 Rev 0 Cable fault location machine Cabl… · shall guide operator through step-by-step fault locating procedures, 4.1.11 Optimized support of all Arc reflection methods

SPECIFICATION FOR CABLE FAULT LOCATION MACHINE

REFERENCE REV

CP_TSSPEC_221 1

PAGE 8 OF 19

9. ENVIRONMENTAL MANAGEMENT

An Environmental Management Plan/System shall be set up in order to ensure the proper environmental management and compliance of the cable fault location machine during its entire life cycle (i.e. during design, development, production, installation, operation and maintenance, decommissioning as well as Rehabilitation, Recycling or Disposal phase/s). Guidance on the requirements for an environmental management plan/system may be found in ISO 14001:2015 standards. The details shall be subject to agreement between City Power and the Supplier. This is to ensure that the asset created conforms to environmental standards and City Power SHERQ Policy

Page 9: CP TSSPEC 221 Rev 0 Cable fault location machine Cabl… · shall guide operator through step-by-step fault locating procedures, 4.1.11 Optimized support of all Arc reflection methods

SPECIFICATION FOR CABLE FAULT LOCATION MACHINE

REFERENCE REV

CP_TSSPEC_221 1

PAGE 9 OF 19

ANNEXURE A - BIBLIOGRAPHY

None

Page 10: CP TSSPEC 221 Rev 0 Cable fault location machine Cabl… · shall guide operator through step-by-step fault locating procedures, 4.1.11 Optimized support of all Arc reflection methods

SPECIFICATION FOR CABLE FAULT LOCATION MACHINE

REFERENCE REV

CP_TSSPEC_221 1

PAGE 10 OF 19

ANNEXURE B - REVISION INFORMATION

DATE REV. NO. NOTES

August 2014

March 2019

0

1

First issue

Second issue

Removed trailer

Page 11: CP TSSPEC 221 Rev 0 Cable fault location machine Cabl… · shall guide operator through step-by-step fault locating procedures, 4.1.11 Optimized support of all Arc reflection methods

SPECIFICATION FOR CABLE FAULT LOCATION MACHINE

REFERENCE REV

CP_TSSPEC_221 1

PAGE 11 OF 19

ANNEXURE C - Item No. 1 – Cable fault location machine Schedule A: Purchaser's specific requirements Schedule B: Guarantees and technical particulars of equipment offered

Item Sub clause of CP_TSSPEC_000

Description Schedule A Schedule B

1 Manufacturer XXXX

2 Location XXXX

3 Description

110 to 230 V, 50/60 Hz±5%, single phase supply. Yes/No

4 Digital Time Domain Reflectometer

Yes/No

1. Time Domain Reflection Measurement on 3 phases simultaneously.

Yes/No

2. Arc Reflection Measurement Yes/No

3. Impulse Current Mode. Yes/No

4. Decay Method. Yes/No

5. Intermittent Fault Location

(IFL) Yes/No

6. Symmetrical / Unsymmetrical

reflection measurements. Yes/No

7. The pre-location unit should be very convenient to operate with on-line guidance system, which shall guide operator through step-by-step fault locating procedures.

Yes/No

8. Automatic trace analysis with cable end and fault position indication.

Yes/No

9. Large bright 10.4”

Touchscreen color display Yes/No

10. High resolution by sampling

rate of 400 Mhz Yes/No

11. Internal Compensation for better fault location at short range

Yes/No

12. Large 2 GB memory for data

storage Yes/No

13. USB interface for memory

stick and printer Yes/No

Note: Ticks, Cross [√, X], Astrick [*], Word [Noted] or TBA [“To Be Advice”] will not be accepted.

Tender Number: _________________________________________________________________

Tenderer’s Authorised Signatory: _________________________________ __________________

Name in block letters Signature

Full name of company: _____________________________________________________________

Page 12: CP TSSPEC 221 Rev 0 Cable fault location machine Cabl… · shall guide operator through step-by-step fault locating procedures, 4.1.11 Optimized support of all Arc reflection methods

SPECIFICATION FOR CABLE FAULT LOCATION MACHINE

REFERENCE REV

CP_TSSPEC_221 1

PAGE 12 OF 19

Item Sub clause of CP_TSSPEC_000

Description Schedule A Schedule B

14. Report Generation in PDF

format Yes/No

15. ARMslide 15 Measurement in one ARM shot for selection of best trace

Yes/No

16. Automatic storage of all

measurements Yes/No

17. Professional Range adjustment for optimized display of distant details

Yes/No

18. It shall allow evaluation of direct measurement on phase, comparison of two phases, and difference of two phases.

Yes/No

19. Shall have built in battery, capable of operating the system for continuous period of 4 Hrs without charging / replacement. Necessary intelligent charger shall also be provided.

Yes/No

20. Pulse width: Shall be continuously variable from a nano second range to10 micro second range.

Yes/No

21. Measuring range of 20m to

at least 160 km. Yes/No

5 Continuously variable Surge generator:

1. Report Generation in PDF

format Yes/No

2. ARMslide 15 Measurement in one ARM shot for selection of best trace

Yes/No

3. Automatic storage of all

measurements Yes/No

4. Burning 0 to 8kV with 700mA Yes/No

5. Burning 0 to 20kV with 100mA Yes/No

Note: Ticks, Cross [√, X], Astrick [*], Word [Noted] or TBA [“To Be Advice”] will not be accepted.

Tender Number: _________________________________________________________________

Tenderer’s Authorised Signatory: _________________________________ __________________

Name in block letters Signature

Full name of company: _____________________________________________________________

Page 13: CP TSSPEC 221 Rev 0 Cable fault location machine Cabl… · shall guide operator through step-by-step fault locating procedures, 4.1.11 Optimized support of all Arc reflection methods

SPECIFICATION FOR CABLE FAULT LOCATION MACHINE

REFERENCE REV

CP_TSSPEC_221 1

PAGE 13 OF 19

Item Sub clause of CP_TSSPEC_000

Description Schedule A Schedule B

6. Test and locate sheath faults with step voltage of 0 to 5kV and 0 to 10kV

Yes/No

7. Pre-Location Methods ARM, ICE,

Decay Yes/No

8. Must be capable of being installed

with remote control panel Yes/No

9. Output voltage 0 to 4kV / 2000J, 0 to 8kV / 2000J, 0 to 16kV 2000J, 0 to 32kV / 2000J

Yes/No

10. Single shot / pulse adjustable between 3 to 10 seconds and single pulse.

Yes/No

11. During HV Testing leakage current shall be auto ranging and the system should be capable of auto shutdown and display of breakdown voltage during testing on control panel.

Yes/No

12. Burn current must be adjustable to a maximum of at least 500 mA at 8 kV in order to facilitate pre conditioning of faults. Yes/No

Yes/No

13. Discharge devices shall be part

of the system Yes/No

14. All modes including insulation testing, DC testing, breakdown recognition, fault conditioning/burning, surge generator, insulation testing etc. with their individual set-ups shall be selectable and operable from this unit.

Yes/No

15. It shall have LCD display of sufficient size with one rotary control button and emergency switch. Display shall guide user through the complete testing and cable fault locating modes and shall also give status information, inputs (to surge generator, DC tester, insulation tester etc. with regard to their individual set-up) and results.

Yes/No

Note: Ticks, Cross [√, X], Astrick [*], Word [Noted] or TBA [“To Be Advice”] will not be accepted.

Tender Number: _________________________________________________________________

Tenderer’s Authorised Signatory: _________________________________ __________________

Name in block letters Signature

Full name of company: _____________________________________________________________

Page 14: CP TSSPEC 221 Rev 0 Cable fault location machine Cabl… · shall guide operator through step-by-step fault locating procedures, 4.1.11 Optimized support of all Arc reflection methods

SPECIFICATION FOR CABLE FAULT LOCATION MACHINE

REFERENCE REV

CP_TSSPEC_221 1

PAGE 14 OF 19

Item Sub clause of CP_TSSPEC_000

Description Schedule A Schedule B

16. All necessary safety interlocks / safety loops shall be incorporated with warning / error massage. System shall not raise any voltage in case it found wrong with the safety loops / interlocks.

Yes/No

17. The system must be accompanied by an easy to use software, which visualizes the recorded data in an understandable way on a PC.

Yes/No

18. Storage of the recorded data shall happen automatically to a suitable medium, like an USB stick.

Yes/No

19. The software shall provide the possibility to supplement the measurements with additional data about cable and measurement details

Yes/No

20. Printouts and export of the

data are required Yes/No

21. Safety of the operator and the equipment shall be at prime consideration during operation comprehensive self safety check shall be built in to the system and shall carry out automatically by the system before raising any voltage.

Yes/No

22. It shall include checking ground loop resistance, step potential, internal emergency-OFF button, over temperature, over current/voltage shut-off features.

Yes/No

Note: Ticks, Cross [√, X], Astrick [*], Word [Noted] or TBA [“To Be Advice”] will not be accepted.

Tender Number: _________________________________________________________________

Tenderer’s Authorised Signatory: _________________________________ __________________

Name in block letters Signature

Full name of company: _____________________________________________________________

Page 15: CP TSSPEC 221 Rev 0 Cable fault location machine Cabl… · shall guide operator through step-by-step fault locating procedures, 4.1.11 Optimized support of all Arc reflection methods

SPECIFICATION FOR CABLE FAULT LOCATION MACHINE

REFERENCE REV

CP_TSSPEC_221 1

PAGE 15 OF 19

Item Sub clause of CP_TSSPEC_000

Description Schedule A Schedule B

6 Acoustic and magnetic Pin-pointing Set

Yes/No

1. Consisting of a receiver and ground sensor with accessories, headphones, connection cables and transport box or mountings

Yes/No

2. High acoustic and magnetic

field sensitivity Yes/No

3. High performance electronic suppression of external noise and interference

Yes/No

4. Excellent acoustic characteristics (frequency range 100 Hz to 1.5 kHz)

Yes/No

5. Active ear protection by a 85

db limiter Yes/No

6. Measurement of magnetic field and sound coincidence with automatic selection and calibration of the measuring range

Yes/No

7. Automatic contactless turn off of the Headset, as the hand approaches the handle

Yes/No

8. Indication of cable position in

respect to the sensor Yes/No

9. Indication of the direction to

the fault Yes/No

10. Built in adjustable filters for the suppression of interference 270 Hz ... 1,5 kHz

Yes/No

11. Bright sun readable colour display with at least 320 x 240 pixels

Yes/No

Note: Ticks, Cross [√, X], Astrick [*], Word [Noted] or TBA [“To Be Advice”] will not be accepted.

Tender Number: _________________________________________________________________

Tenderer’s Authorised Signatory: _________________________________ __________________

Name in block letters Signature

Full name of company: _____________________________________________________________

Page 16: CP TSSPEC 221 Rev 0 Cable fault location machine Cabl… · shall guide operator through step-by-step fault locating procedures, 4.1.11 Optimized support of all Arc reflection methods

SPECIFICATION FOR CABLE FAULT LOCATION MACHINE

REFERENCE REV

CP_TSSPEC_221 1

PAGE 16 OF 19

Item Sub clause of CP_TSSPEC_000

Description Schedule A Schedule B

12. Comparison of last and the

new measurement on screen Yes/No

13. Graphical indication of the

magnetic field Yes/No

14. Peak hold of the magnetic

field value Yes/No

15. Indication of the acoustic

signal detection Yes/No

16. Indication of all adjustments

and settings Yes/No

17. Distance Measurement Yes/No

18. The unit must have a floating microphone suspension to reduce body sounds of the sensors and provide a solid standing even on sloped surfaces.

Yes/No

19. The unit must have a filter setting for Low Pass (100 to 400Hz), Band Pass (150 to 600Hz), High Pass (200 to 1500Hz)

Yes/No

7 Power Supply for Equipment:

1. 3000 W system Yes/No

2. Integrated inverter Yes/No

3. Integrated charger Yes/No

4. Four Deep cycle maintenance free

batteries Yes/No

5. Strong durable metal enclosure to ensure batteries are kept in safe and stationary position

Yes/No

8 Installation

1. Durable and strong floor must be installed with a minimum thickness of 19mm and should be covered with industrial strength and durable non slip rubber tiles to ensure equipment is mounted properly.

Yes/No

Note: Ticks, Cross [√, X], Astrick [*], Word [Noted] or TBA [“To Be Advice”] will not be accepted.

Tender Number: _________________________________________________________________

Tenderer’s Authorised Signatory: _________________________________ __________________

Name in block letters Signature

Full name of company: _____________________________________________________________

Page 17: CP TSSPEC 221 Rev 0 Cable fault location machine Cabl… · shall guide operator through step-by-step fault locating procedures, 4.1.11 Optimized support of all Arc reflection methods

SPECIFICATION FOR CABLE FAULT LOCATION MACHINE

REFERENCE REV

CP_TSSPEC_221 1

PAGE 17 OF 19

Item Sub clause of CP_TSSPEC_000

Description Schedule A Schedule B

2. Installation should have

internal lighting system for working at night.

Yes/No

3. Installation should include all wiring with DB Board, Separation Transformer, central earth points and a minimum of two additional 3 point plugs which is connected to separate breakers.

Yes/No

4. Mounted but removable

rotating office chair. Yes/No

5. Additional storage shelf’s for

small portable equipment Yes/No

6. Counter top for control units

and additional work space.

Yes/No

7. Installation should have internal red/green warning lights system indicating the presence of high voltage or when the system is earthed.

Yes/No

8. Installation should include

mounting brackets for the ground microphone.

Yes/No

9. Installation should include a discharge rod with a resister to ensure soft discharge with a minimum voltage rating of 50kV

Yes/No

9 Training

Is theoretical and field training on operating the equipment being offered?

Yes/No

10 ISO 9001 accreditation certificated

Yes/No

11 ISO 14001 accreditation corticated

Yes/No

Note: Ticks, Cross [√, X], Astrick [*], Word [Noted] or TBA [“To Be Advice”] will not be accepted.

Tender Number: _________________________________________________________________

Tenderer’s Authorised Signatory: _________________________________ __________________

Name in block letters Signature

Full name of company: _____________________________________________________________

Page 18: CP TSSPEC 221 Rev 0 Cable fault location machine Cabl… · shall guide operator through step-by-step fault locating procedures, 4.1.11 Optimized support of all Arc reflection methods

SPECIFICATION FOR CABLE FAULT LOCATION MACHINE

REFERENCE REV

CP_TSSPEC_221 1

PAGE 18 OF 19

Item No. 1 – CABLE FAULT LOCATION MACHINE

Deviation schedule

Any deviations offered to this specification shall be listed below with reasons for deviation. In addition, evidence shall be provided that the proposed deviation will at least be more cost-effective than that specified by City Power.

Item Sub clause of CP_TSSPEC_000

Proposed deviation

Tender Number: _________________________________________________________________

Tenderer’s Authorised Signatory: _________________________________ __________________

Name in block letters Signature

Full name of company: _____________________________________________________________

Page 19: CP TSSPEC 221 Rev 0 Cable fault location machine Cabl… · shall guide operator through step-by-step fault locating procedures, 4.1.11 Optimized support of all Arc reflection methods

SPECIFICATION FOR CABLE FAULT LOCATION MACHINE

REFERENCE REV

CP_TSSPEC_221 1

PAGE 19 OF 19

ANNEXURE D – Stock Items

It is not intended that City Power should keep stock of these items.


Recommended