Page 1: CPVC -  · PDF fileCPVC Fitting Socket Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439) Size(mm) Schedule D d1 d2 A I 20 40 33.9 26.87 26.57 2.6 21 25 40 44 33.66 33.27 2.6 32
Page 2: CPVC -  · PDF fileCPVC Fitting Socket Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439) Size(mm) Schedule D d1 d2 A I 20 40 33.9 26.87 26.57 2.6 21 25 40 44 33.66 33.27 2.6 32

CPVCWhen dealing with fire protection, you need a piping system you can depend on. Paradise BlazeMasterⓇ CPVC pipe and fittings are designed specifically for fire sprinkler systems based on more than 40 years of proven experience.

Paradise Industry Co.,Ltd. is the only Licensed Manufacture in Korea to supply CPVC pipe and fittings to the market by using UL approved Lubrizol material. Paradise BlazeMasterⓇ CPVC takes fire sprinkler systems to a level of superior performance that exceeds your expectations.

Resistance to corrosion and chemical attackResistance to heat and pressureFlame resistance and mechanical strength at high temperaturesEasy installation and economy in total installation cost

Direct exposure to flame at 878℃(Water Pressure Resistance: 1.2Mpa)

The inner side of the pipe maintains good condition after cutting.

LOI(Limiting Oxygen Index)

Heat Conductivity

Material LOI

CPVC 60

Cotton 16 ~ 17

PE 17

PP / PB / ABS 18

PVC 45

Oxygen composition in the air : 21%

Material Heat Conductivity(Btu/ft hr℉)

Insulation 0.25

CPVC 0.95

Steel Pipe 325

Copper Pipe 2.688

Page 3: CPVC -  · PDF fileCPVC Fitting Socket Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439) Size(mm) Schedule D d1 d2 A I 20 40 33.9 26.87 26.57 2.6 21 25 40 44 33.66 33.27 2.6 32

Paradise builds the reliability, we guarantee

3 pageParadise

( listed)

PIPES

( listed)

FITTINGS

Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439)Fitting 45° ElbowSize Schedule D d1 d2 J I

20 40 33.8 26.87 26.57 8 21

25 40 42 33.66 33.27 9 23

32 40 51 42.42 42.04 11 27

40 80 60 48.56 48.11 12 37

50 80 73 60.63 60.17 16 42

65 80 88 73.38 72.85 18 47

80 80 105 89.31 88.70 21 50

Standard (ASTM F442 SDR13.5)PipeSize(mm) Do = Avg.OD(mm) t = min.Thickness(mm)

20 26.7 1.98

25 33.4 2.46

32 42.2 3.12

40 48.2 3.58

50 60.3 4.47

65 73.0 5.41

80 88.9 6.58

Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439)Fitting TeeSize(mm) Schedule D d1 d2 A I

20 40 33.8 26.87 26.57 14.4 21

25 40 41.9 33.66 33.27 18 23

32 40 50.4 42.42 42.04 23 27

40 80 60 48.56 48.11 26 37

50 80 73 60.63 60.17 32 42

65 80 89 73.38 72.85 40 47

80 80 106 89.30 88.70 48 50

Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439)Fitting 90′ ElbowSize(mm) Schedule D d1 d2 A I

20 40 33.8 26.87 26.57 14.4 21

25 40 41.2 33.66 33.27 18 23

32 40 50.5 42.42 42.04 23 27

40 80 59.9 48.56 48.11 26 37

50 80 73.0 60.63 60.17 32 42

65 80 88.9 73.38 72.85 40 47

80 80 106.0 89.31 88.70 53 50

Fitting Reducing Tee Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439)

Size(mm) Schedule D d1 d2 D2 d3 d4 A B I1 I2

25×20 40 42 33.66 33.27 33.8 26.87 26.57 15.4 18.0 23 21

32×20 40 50.4 42.42 42.04 33.8 26.87 26.57 16.4 23.0 27 21

32×25 40 50.4 42.42 42.04 41.2 33.66 33.27 18.0 22.5 27 23

40×20 80 60 48.56 48.11 35 26.87 26.57 17.3 26.0 37 27

40×25 80 60 48.56 48.11 44 33.66 33.27 18.0 26.0 37 32

40×32 80 60 48.56 48.11 53.4 42.42 42.04 23.0 25.7 37 35

50×20 80 73 60.63 60.17 35 26.87 26.57 16.3 32.0 42 27

50×25 80 73 60.63 60.17 44 33.66 33.27 18.0 32.5 42 32

50×32 80 73 60.63 60.17 53.4 42.42 42.04 23.0 32.7 42 35

50×40 80 73 60.63 60.17 60 48.56 48.11 26 33.2 42 37

65×25 80 89 73.38 72.85 44 33.667 33.27 18 37.7 47 32

65×32 80 89 73.38 72.85 53.4 42.42 42.04 23 38.2 48 35

65×40 80 89 73.38 72.85 60 48.56 48.11 26 38.7 47 37

65×50 80 89 73.38 72.85 73 60.63 60.17 32 38.7 47 42

80×50 80 106 89.31 88.70 73 60.63 60.17 32 48 50 42

80×65 80 106 89.31 88.70 89 73.38 72.85 40 48 50 47

Page 4: CPVC -  · PDF fileCPVC Fitting Socket Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439) Size(mm) Schedule D d1 d2 A I 20 40 33.9 26.87 26.57 2.6 21 25 40 44 33.66 33.27 2.6 32

CPVCStandard (Sch.40 : ASTM F438, Sch.80 : ASTM F439)Fitting Socket

Size(mm) Schedule D d1 d2 A I

20 40 33.9 26.87 26.57 2.6 21

25 40 44 33.66 33.27 2.6 32

32 40 53.4 42.42 42.04 4 35

40 80 60 48.56 48.11 5 37

50 80 73 60.63 60.17 6 42

65 80 89 73.38 72.85 6 47

80 80 106 89.31 88.70 6 50

Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439)Fitting Reducing SocketSize(mm) Schedule D d1 d2 D2 d3 d4 A B I1 I2

25×20 40 42 33.66 33.27 33.8 26.87 26.57 15.4 18.0 23 21

32×25 40 50.4 42.42 42.04 41.2 33.27 33.27 18.0 22.5 27 23

40×25 80 60 48.56 48.11 44 33.27 33.27 18.0 26.0 37 32

40×32 80 60 48.56 48.11 53.4 42.04 42.04 23.0 25.7 37 35

50×25 80 73 60.63 60.17 44 33.27 33.27 18.0 32.5 42 32

50×32 80 73 60.63 60.17 53.4 42.04 42.04 23.0 32.7 42 35

50×40 80 73 60.63 60.17 60 48.11 48.11 26 33.2 42 37

65×50 80 89 73.38 72.85 73 60.17 60.17 32 38.7 47 42

80×50 80 106 89.31 88.70 73 60.17 60.17 32 48 50 42

80×65 90 106 89.31 88.70 89 72.85 72.85 40 48 50 47

Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439)Fitting Sprinkler Head AdapterSize(mm) Schedule D d1 d2 T B I

20×PT15 40 33.8 26.87 26.57 PT 1/2″ 38 21

25×PT15 80 44 33.66 33.27 PT 1/2″ 50 32

Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439)CPVC Fitting Valve Socket

Size(mm) Schedule D d1 d2 T B IWt.

(g/ea)Packing(ea/Box)

ULApproval

20×BSPF25(1” X BSPF1”)

80 44.0 33.66 33.27 PF 1″ 46 32 57 200

Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439)CPVC Fitting Reducing Bushing

Size(mm) Schedule D1 d1 d2 D2 d3 d4 A I1 I2Wt.

(g/ea)Packing(ea/Box)

ULApproval

50×25(2”X1”)

80 60.33 51.10 28 70 33.66 33.27 2.9 43 32 160 100

50×32(2”X1-1/4”)

80 60.33 51.10 35 70 42.42 42.04 4.0 43 35 130 100

50×40(2”X1-1/2”)

80 60.33 51.10 40 70 48.56 48.11 5.0 43 37 100 100

Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439)Fitting Female Adapter w/t Brass

Size(mm) Schedule D0 D d1 d2 T B IWt.

(g/ea)Packing(ea/Box)

ULApproval

25×PT25(1″×BSPT1″)

80 54.1 44.0 33.66 33.27 BSPT 1″ 50 32 150 100 ○

32×PT32(1-1/4″×BSPT1-1/4″)

80 64 54 42.42 42.04 BSPT 1-1/4″ 60 35 230 60 ○

40×PT40(1-1/2″×BSPT1-1/2)

80 73.5 60 48.56 48.11 BSPT 1-1/2″ 70 38 280 45 ○

50×PT50(2″×BSPT2″)

80 90 73 60.63 60.17 BSPT 2″ 86.5 42 420 25 ○

CPVC Fitting Female Adapter w/t Steel

Size(mm) Schedule D0 D1 d1 d2 T B IWt.

(g/ea)Packing(ea/Box)

ULApproval

20×BSPT50(2” X BSPT2”)

80 82 73 60.63 60.17 PT 2″ 77 42 790 30

Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439)

Page 5: CPVC -  · PDF fileCPVC Fitting Socket Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439) Size(mm) Schedule D d1 d2 A I 20 40 33.9 26.87 26.57 2.6 21 25 40 44 33.66 33.27 2.6 32

Paradise builds the reliability, we guarantee

5 pageParadise

Solvent CementDiv. Volume (㎖/can) Net Wt. (g.can) Packong (can/Box)

Pint 473 500 12

Quart 946 1,000 12

CPVC Fitting Male Adapter

Size(mm) Schedule D0 D d1 d2 T B IWt.

(g/ea)Packing(ea/Box)

ULApproval

25×BSPF25(1″×BSPT1″)

80 52.6 44 33.66 33.27 BSPF 1″ 46.6 28 210 80 ○

32×BSPT32(1″×BSPT1″)

80 52.6 44 33.6 33.27 BSPT 1″ 46.6 28 215 80 ○

40×BSPT40( 1-1/2″×BSPT 1-1/2″)

80 66 60 48.56 48.11BSPT 1-1/2″

63 37 360 25 ○

50×BSPT50(2″×BSPT2″)

80 82 73 60.63 60.17 BSPT 2″ 77 42 580 25

Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439)

CPVC Fitting Spigot Female Adapter

Size(mm) Schedule D d1 d2 T B IWt.

(g/ea)Packing(ea/Box)

ULApproval

25×BSPT25(1″×BSPT1″) (Female)

80 33.4 25.8 25.8 BSPT 1″ 50.0 32 140 100 ○

25×BSPT25(1″×BSPT1″) (Male)

80 33.4 25.5 25.5 BSPT 1″ 46.6 32 210 80

25×BSPF25(1″×BSPF1″) (Spigot “M”)

80 33.4 25.5 25.5 BSPF 1″ 46.6 32 200 80

Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439)

Fitting CrossSize(mm) Schedule D d1 d2 A I

20 40 33.8 26.87 26.57 14.4 21

25 80 44 33.66 33.27 18 32

32 80 53.4 42.42 42.04 23 35

Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439)

Fitting CapSize(mm) Schedule D d1 d2 I

20 40 33.8 26.87 26.57 27

25 80 44 33.66 33.27 32

32 80 53.4 42.42 42.04 35

40 80 60 48.56 48.11 37

50 80 73 60.63 60.17 42

Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439)

Fitting FlangeSize(mm) Schedule D0 D1 D2 d1 d2 I T n Φe

50 80 155 120 73 60.63 60.17 42 20 4 18

65 80 185 145 92 73.38 72.85 70 22 4 18

80 80 200 150 110 89.31 88.70 72 25 8 18

Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439)

Fitting Gasket (EPDM)Size(mm) D1 D2 D3 D4 n Φe

50 68 83 120 153 4 19

65 86 101 140 173 4 19

80 98 112 150 183 8 19

Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439)

Page 6: CPVC -  · PDF fileCPVC Fitting Socket Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439) Size(mm) Schedule D d1 d2 A I 20 40 33.9 26.87 26.57 2.6 21 25 40 44 33.66 33.27 2.6 32

CPVCBlazeMasterⓇ CPVC pipe and fittings are Listed by Underwriters Laboratories (UL & C-UL) for use in:

Light Hazard occupancies as defined in the Standard for Installation of Sprinkler Systems, NFPA 13 (regardless of the height of the building).

Residential occupancies as defined in the Standard for Installation of Sprinkler Systems in Residential Occupancies up to Four Stories in Height, NFPA 13R.

Ordinary Hazard Installations. Sections 6.3.6.2 of NFPA 13 (2010 Edition) and 5.2.2.3 of NFPA 13R (2010 Edition) permit the use of pipe or tube listed for light hazard occupancies to be installed in ordinary hazard rooms of otherwise light hazard occupancies where the room does not exceed 400 ft2 (37 m2). BlazeMasterⓇ CPVC pipe and fittings may be installed in these installations in accordance with these installation instructions.

Residential occupancies as defined in the Standard for Sprinkler Systems in One and Two Family Dwellings and Manufactured Homes, NFPA 13D.

Air plenums, as defined by the Installation of Air Conditioning and Ventilating Systems, NFPA 90

Installation of Private Fire Service Mains and Their Appurtenances, NFPA 24

System risers in residential buildings up to four stories in height, NFPA 13R and 13D.

See UL Fire Protection Equipment Directory, categories VIWT and HFYH. BlazeMasterⓇ fire sprinkler systems shall be employed in wet-pipe systems. (A wet-pipe system contains water and is connected to a water supply so that the water will discharge immediately when the sprinkler is opened.)

BlazeMasterⓇ CPVC pipe manufactured by Paradise must never be used in a system using compressed air or other gases.

National Fire Protection Association Standards 13, 13R, 13D, and NFPA 24 must be referenced and followed for design and installation requirements.

Where Can BlazeMasterⓇ Fire Sprinkler Systems Be Used?

• Cut pipe squarely using a ratchet cutter, a wheel-type plastic tubing cutter, a power saw or a fine toothed saw.

• Ratchet cutter should not apply when temp. below 10。C

• Use a chamfering tool or other tool to remove burrs and filings from the inside and outside of the pipe.

• Apply solvent cement to outside of pipe using a brush or a dauber.

• Apply solvent cement to the fitting socket.

• Do not puddle the cement in fitting.

• Immediately insert the pipe into the fitting socket while rotating the pipe 1/4 turn. This ensures against potential “leak” tracks in the solvent cement.

• Make sure that the pipe bottoms in the socket and hold for 10~15 seconds.

• Do not apply external shock or internal pressure until the adhesive is absolutely cured.

Installing CPVC1. Cutting 2. Deburring

3-1. Cement Application to pipe 3-2. Cement Application to fittings

4. Assembly 5. Observe specified curing time.

Page 7: CPVC -  · PDF fileCPVC Fitting Socket Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439) Size(mm) Schedule D d1 d2 A I 20 40 33.9 26.87 26.57 2.6 21 25 40 44 33.66 33.27 2.6 32

Paradise builds the reliability, we guarantee

7 pageParadise

Minimum Cure Prior to Pressure Testing

Solvent cement can be applied at temperatures below 4。C for pipe 2” in size and larger, however the temperature of the system must be raised to 4。C or higher and allowed to cure per the above recommendations prior to pressure testing. When bringing cement, pipe or fittings in from the outside, be sure they are brought up to room temperature before using the 16。C to 49。C cure schedule.

Curing time

Hangers and Support

Paradise BlazeMasterⓇ CPVC is a tough, corrosion resistant material, but does not have the mechanical strength of steel. Reasonable care must be exercised in handling Paradise BlazeMasterⓇ CPVC pipe and fittings. They must not be dropped or have objects dropped on them. If improper handling results in scratches, splits, or gouges, the damaged section shall be cut out and discarded.

Paradise BlazeMasterⓇ CPVC pipe must be covered with a nontransparent material when stored out of doors for extended periods of time. Brief exposure to direct sunlight on the job site may result in color fade but will not affect physical properties. Paradise BlazeMasterⓇ fittings should be stored in their original containers to keep them free from dirt and reduce the possibillity of damage. Caution should be taken not to overstack boxes of Paradise BlazeMasterⓇ fittings in extreme temperature environments (≻ 65℃).

General Handling and Storage

BlazeMasterⓇ pipe is rigid, it requires fewer supports than flexible plastic systems.

Expansion Loop and Offset Configuration

(mm) (inch) 16℃ to 49℃ (60℉ to 120℉) 4℃ to 15℃ (39℉ to 59℉) -18℃ to 4℃ (0℉ to 39℉)

20 3/4″ 1 hr. 4 hrs. 48 hrs.

25 1″ 1 1/2 hr. 4 hrs. 48 hrs.

32×40 1 1/4″ & 1 1/2″ 3 hrs. 32 hrs. 10 days

50 2″ 8 hrs. 48 hrs.

65×80 2 1/2″ & 3″ 24 hrs. 96 hrs.

mm inches meters feet

20 3/4″ 1.7 5-1/2

25 1″ 1.8 6

32 1-1/4″ 2.0 6-1/2

40 1-1/2″ 2.1 7

50 2″ 2.4 8

65 2-1/2″ 2.7 9

80 3″ 3.0 10

Nominal Size Maximum Support Spacing

Loop Off set Change of direction

Ambient Temperature During CurePipe Size

Page 8: CPVC -  · PDF fileCPVC Fitting Socket Standard (Sch.40 : ASTM F438, Sch.80 : ASTM F439) Size(mm) Schedule D d1 d2 A I 20 40 33.9 26.87 26.57 2.6 21 25 40 44 33.66 33.27 2.6 32

Headquarters·Factory65-2 Chunui Dong, Wonmi Gu, Bucheon Si, Kyoungki Do, KoreaTEL :032)675-2288(Rep.)

FAX:032)675-6297

Seoul Office683-116 Hannam Dong, Yongsan Gu, Seoul, KoreaTEL :02)795-2300(Rep.)FAX:02)797-0910(Overseas Team)Home Page:www.paradise-ind.co.kr www.fesco.co.kr

The ownership of the data contained in the catalog is vested in Paradise Ind. co.,Ltd. The content of the catalog is subject to change without prior notice in order to achieve our goal to upgrade out

products trough constantly improving out technology. 2013. 08. Rev. 5

Please strictly refer to Paradise BlazeMasterⓇ CPVC Installation Manual for right CPVC application.


Recommended