NVLAP Lab Code 500089-0 Test Report Number: PL08879-001A RESTL-R010 Rev F This report contains data that are not covered by the NVLAP accreditation. Cree, Inc | 9201 Washington Avenue | Racine, WI 53406 Page 1 of 13 Report Number: PL08879-001A Model: OSQ-A-xx-3ME-K-30K-ULxxxxx Date: 08/05/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher Strom Cree, Inc. 9201 Washington Avenue Racine, WI 53406 Prepared By: Approved By: Linjie Li, LC, Test Engineer Christopher McLaurin, Photometric Specialist
Transcript

NVLAP Lab Code 500089-0

Test Report Number: PL08879-001A RESTL-R010 Rev F

This report contains data that are not covered by the NVLAP accreditation.

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 1 of 13

Report Number: PL08879-001A

Model: OSQ-A-xx-3ME-K-30K-ULxxxxx

Date: 08/05/2016

Cree Racine Engineering Services Testing Laboratory

(RESTL) Photometric Testing and Evaluation

Report

Prepared For:

Christopher Strom

Cree, Inc.

9201 Washington Avenue

Racine, WI 53406

Prepared By: Approved By:

Linjie Li, LC, Test Engineer Christopher McLaurin, Photometric Specialist

NVLAP Lab Code 500089-0

Test Report Number: PL08879-001A RESTL-R010 Rev F

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 2 of 13

Product Information

Manufacturer Cree, Inc.

Model Number (SKU) OSQ-A-xx-3ME-K-30K-ULxxxxx

Serial Number PL08879-001

LED Type MDA

Product Description

Brown finned metal housing. Two circuit boards each with six LEDs. Two optic carriers each with one black plastic uplight shield. One clear plastic optical lens below each LED.

Driver Information (Where Applicable)

Philips XI150C105V140CNF1

Length Width Height

20.0” 19.0” 4.0”

Sample

The following sample was submitted for evaluation

NVLAP Lab Code 500089-0

Test Report Number: PL08879-001A RESTL-R010 Rev F

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 3 of 13

Key Photometric Data Sphere Output Goniophotometer

Luminous Flux 16164.5 16046.1 lm

Efficacy 128.28 126.76 lm/W

Correlated Color Temperature (CCT) 2924 K

Color Rendering Index (CRI) 71

R9 -29

Duv 0.00101117

S/P Ratio* 1.14

Sphere Goniophotometer

Electrical Measurements 120V 277V 120V 277V

Input Wattage 126.01 124.24 126.59 124.16 W

Input Current 1.05 0.46 1.06 0.45 A

Input Voltage 119.98 277.05 120.14 277.03 V

Power Factor 0.998 0.985 0.999 0.986

Off-State Power 0 0 0 0 W

Total Harmonic Distortion (Voltage) 0.04 0.05 0.12 0.06 %

Total Harmonic Distortion (Amperage) 4.05 4.55 3.97 4.50 %

Note: All photometric measurements taken at 120VAC.

Luminous Intensity Distribution Goniophotometer

Max Candela 10297.4 Cd

Angle of Max Candela (Horizontal) 60 ˚

Angle of Max Candela (Vertical) 62.5 ˚

Key Test Parameters Sphere Output Goniophotometer

Stabilization Time 86 35 min

Total Operating Time (Stabilization + Test) 90 55 min

Ambient Temperature 25.0 24.8 ˚C

NVLAP Lab Code 500089-0

Test Report Number: PL08879-001A RESTL-R010 Rev F

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 4 of 13

Chromaticity Coordinates

x y u v u’ v’ Duv

0.4440 0.4090 0.2530 0.3496 0.2530 0.5243 0.00101117

Color Rendering Index Details

Ra R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14

71 68 80 90 69 67 72 79 46 -29 53 64 45 70 94

Chromaticity Diagram

NVLAP Lab Code 500089-0

Test Report Number: PL08879-001A RESTL-R010 Rev F

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 5 of 13

Spectral Distribution

λ(nm) W/nm λ(nm) W/nm λ(nm) W/nm

360 0.000113 530 0.168212 700 0.041909

370 0.000059 540 0.190901 710 0.030779

380 0.000078 550 0.213584 720 0.022787

390 0.000068 560 0.243506 730 0.016645

400 0.000100 570 0.277544 740 0.012209

410 0.002871 580 0.310191 750 0.009001

420 0.018635 590 0.331822 760 0.006593

430 0.065868 600 0.333878 770 0.004898

440 0.147224 610 0.318670 780 0.003581

450 0.155409 620 0.286567 790 0.002586

460 0.057043 630 0.247941 800 0.001847

470 0.027058 640 0.206317 810 0.001318

480 0.019105 650 0.165816 820 0.000913

490 0.025262 660 0.130538 830 0.000620

500 0.053304 670 0.099633

510 0.096768 680 0.075173

520 0.138350 690 0.056269

Dominant Wavelength 582 nm

Peak Wavelength 598 nm

Spectral Power Distribution (W/nm)

NVLAP Lab Code 500089-0

Test Report Number: PL08879-001A RESTL-R010 Rev F

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 6 of 13

Zonal Lumen Summary

Zone Lumens % of Total Zone Lumens % of Total

0-5 53.0 0.3% 90-95 0 0%

5-10 168.9 1.1% 95-100 0 0%

10-15 285.7 1.8% 100-105 0 0%

15-20 399.2 2.5% 105-110 0 0%

20-25 538.0 3.4% 110-115 0 0%

25-30 714.0 4.4% 115-120 0 0%

30-35 881.1 5.5% 120-125 0 0%

35-40 1,009.6 6.3% 125-130 0 0%

40-45 1,157.6 7.2% 130-135 0 0%

45-50 1,428.4 8.9% 135-140 0 0%

50-55 1,711.8 10.7% 140-145 0 0%

55-60 1,976.3 12.3% 145-150 0 0%

60-65 2,134.2 13.3% 150-155 0 0%

65-70 1,702.1 10.6% 155-160 0 0%

70-75 1,073.9 6.7% 160-165 0 0%

75-80 563.7 3.5% 165-170 0 0%

80-85 216.9 1.4% 170-175 0 0%

85-90 31.8 0.2% 175-180 0 0%

Total 16046.1 lm 100%

NVLAP Lab Code 500089-0

Test Report Number: PL08879-001A RESTL-R010 Rev F

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 7 of 13

Candela Plot Illuminance Plot

Roadway Utilization Roadway Summary Lumens % Lamp

Distribution TYPE III, SHORT

Downward Street Side 11,832.1 73.7%

Downward House Side 4,212.5 26.3%

Downward Total 16,044.7 100%

Upward Street Side 0 0%

Upward House Side 0 0%

Upward Total 0 0%

Total Lumens 16,044.7 100%

NVLAP Lab Code 500089-0

Test Report Number: PL08879-001A RESTL-R010 Rev F

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 8 of 13

Luminaire Classification System

NVLAP Lab Code 500089-0

Test Report Number: PL08879-001A RESTL-R010 Rev F

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 9 of 13

Candela Tabulations

0 5 15 25 35 45 55 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 95 105 115 125 135 145 155 165 175 180

0 2110 2110 2110 2110 2110 2110 2110 2110 2110 2110 2110 2110 2110 2110 2110 2110 2110 2110 2110 2110 2110 2110 2110 2110 2110 2110 2110 2110 2110 2110

2.5 2298 2330 2320 2317 2273 2260 2231 2215 2207 2199 2198 2198 2188 2178 2173 2167 2163 2159 2149 2139 2137 2114 2096 2091 2088 2070 2084 2071 2065 2072

5 2675 2703 2682 2655 2557 2474 2386 2345 2326 2306 2294 2283 2263 2244 2229 2215 2202 2190 2173 2157 2145 2115 2101 2100 2101 2085 2093 2071 2061 2066

7.5 2913 2921 2936 2933 2843 2729 2548 2466 2430 2394 2368 2343 2313 2283 2261 2238 2218 2198 2177 2156 2138 2109 2096 2097 2096 2078 2075 2044 2025 2027

10 2972 2978 3010 3037 2986 2947 2775 2643 2574 2505 2455 2406 2359 2312 2281 2249 2225 2201 2176 2150 2133 2111 2098 2096 2085 2041 2028 1994 1978 1980

12.5 2930 2929 2991 3056 3072 3101 2987 2860 2761 2661 2564 2468 2388 2309 2262 2214 2177 2140 2110 2080 2064 2060 2074 2089 2063 2003 1974 1935 1916 1916

15 2878 2896 2940 3045 3164 3231 3132 3044 2948 2852 2720 2588 2459 2330 2254 2178 2125 2073 2041 2009 1996 1993 2017 2039 2027 1962 1898 1842 1815 1812

17.5 2918 2922 2963 3051 3191 3383 3335 3277 3192 3108 2964 2819 2634 2449 2326 2203 2130 2057 2018 1980 1960 1952 1964 1971 1949 1886 1807 1738 1704 1699

20 2870 2898 3016 3197 3294 3603 3671 3620 3532 3444 3295 3146 2904 2662 2479 2296 2194 2091 2040 1988 1948 1923 1921 1913 1874 1808 1716 1639 1595 1586

22.5 2922 2970 3123 3382 3652 3871 4075 4029 3928 3828 3665 3503 3215 2928 2678 2428 2295 2162 2092 2023 1955 1888 1884 1866 1829 1748 1645 1569 1520 1516

25 3098 3166 3376 3722 4089 4308 4406 4356 4236 4116 3948 3779 3474 3169 2865 2561 2405 2249 2166 2083 1978 1855 1842 1850 1800 1706 1615 1553 1502 1502

27.5 3369 3420 3670 4182 4540 4736 4569 4553 4416 4278 4101 3923 3610 3298 2972 2646 2495 2344 2246 2147 2013 1853 1827 1855 1794 1712 1637 1569 1508 1505

30 3643 3653 3886 4547 4899 5088 4710 4659 4503 4348 4163 3979 3665 3351 3017 2682 2542 2402 2299 2196 2046 1877 1850 1882 1822 1750 1666 1573 1510 1508

32.5 3820 3806 3946 4694 5038 5323 4945 4733 4545 4356 4158 3959 3652 3346 3010 2674 2543 2413 2313 2213 2066 1905 1903 1919 1868 1783 1664 1561 1515 1517

35 3896 3859 3970 4660 5017 5402 5220 4800 4569 4338 4124 3911 3603 3296 2967 2639 2514 2389 2296 2202 2075 1932 1943 1939 1907 1786 1642 1543 1506 1508

37.5 3930 3882 4015 4584 4919 5499 5433 4882 4621 4360 4129 3899 3578 3258 2926 2595 2472 2348 2261 2174 2070 1945 1954 1930 1910 1763 1606 1507 1471 1470

40 4003 3967 4146 4617 4828 5590 5582 5060 4790 4520 4257 3994 3638 3283 2936 2590 2459 2329 2248 2167 2064 1949 1938 1902 1885 1721 1554 1454 1416 1414

42.5 4157 4155 4324 4694 4840 5637 5816 5390 5143 4896 4614 4332 3925 3518 3137 2757 2588 2418 2310 2202 2073 1947 1895 1856 1833 1670 1488 1388 1347 1342

45 5331 5416 5064 4751 4865 5709 6117 5791 5587 5384 5049 4714 4266 3817 3427 3036 2828 2620 2456 2292 2113 1941 1843 1788 1762 1594 1421 1324 1279 1273

47.5 6567 6680 6464 5865 4997 5805 6360 6137 5956 5774 5427 5080 4590 4099 3714 3330 3088 2846 2642 2437 2198 1936 1796 1703 1671 1498 1359 1273 1228 1225

50 7248 7188 7410 7184 6226 5913 6584 6449 6264 6079 5706 5333 4840 4347 3989 3631 3355 3080 2850 2621 2329 1947 1746 1614 1560 1404 1309 1240 1204 1207

52.5 6017 6046 7114 8265 7845 6674 6843 6771 6508 6245 5782 5320 4858 4397 4092 3788 3530 3272 3011 2750 2427 1972 1703 1528 1453 1334 1271 1232 1208 1218

55 5524 5586 6227 7819 9104 8612 7090 7101 6761 6422 5855 5288 4881 4474 4184 3894 3657 3420 3118 2816 2477 2015 1629 1450 1369 1333 1389 1398 1331 1345

57.5 5443 5429 5788 6676 8720 9618 8114 7479 7146 6813 6258 5703 5336 4968 4694 4419 4164 3910 3601 3292 2952 2154 1489 1455 1630 1758 1681 1664 1742 1846

60 4916 4803 5233 6043 7434 9824 9752 8631 8116 7602 7243 6884 6608 6333 6073 5813 5450 5086 4578 4071 3439 2106 1596 2108 2108 1808 1735 2078 2567 2763

62.5 3807 3795 4414 5302 6570 8734 10080 10297 9657 9017 8362 7706 7325 6944 6612 6281 5725 5169 4613 4058 3385 2369 2370 2253 1951 1615 1850 2415 2763 2773

65 2935 2931 3494 4202 5313 7180 9431 10162 9637 9111 8185 7259 6818 6378 5992 5606 5106 4606 4110 3613 3160 2493 2254 1968 1642 1500 1974 2194 2137 2054

67.5 2460 2441 2693 2935 3860 5625 8004 8945 8661 8376 7777 7178 6634 6090 5571 5052 4575 4097 3708 3319 2900 2259 1985 1597 1289 1401 1661 1680 1701 1656

70 1922 1826 1800 1983 2663 4167 6633 7762 7686 7610 7146 6682 6045 5408 4891 4375 3923 3471 3130 2790 2419 2023 1633 1192 1016 1158 1167 1138 968 843

72.5 1237 1079 1004 1176 1855 2990 5175 6524 6544 6564 6162 5761 5217 4674 4191 3708 3219 2731 2435 2138 1956 1655 1185 821 767 771 767 544 444 419

75 544 504 556 664 1214 2091 3775 5201 5267 5334 5082 4830 4434 4038 3641 3244 2708 2172 1874 1576 1379 1168 755 523 493 480 389 352 326 317

77.5 257 255 301 393 767 1443 2667 3917 4036 4154 4030 3906 3560 3216 2885 2555 2028 1500 1258 1017 756 586 394 322 307 308 285 264 245 235

80 176 169 182 224 487 975 1872 2807 2901 2994 2847 2699 2388 2076 1821 1565 1201 837 678 520 373 285 242 218 222 220 210 188 173 164

82.5 110 105 119 145 286 576 1151 1559 1555 1552 1422 1292 1145 998 896 793 603 413 322 231 174 158 154 142 148 148 146 131 115 108

85 61 57 61 71 114 226 392 514 568 622 597 572 542 512 469 425 315 204 156 108 86 84 80 75 81 83 83 72 54 47

87.5 22 17 18 19 26 43 84 121 138 154 137 120 105 90 68 47 35 23 21 18 18 19 21 20 18 14 10 8 5 3

90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

NVLAP Lab Code 500089-0

Test Report Number: PL08879-001A RESTL-R010 Rev F

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 10 of 13

Candela Tabulations (Continued)

0 5 15 25 35 45 55 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 95 105 115 125 135 145 155 165 175 180

92.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

97.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

100 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

102.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

105 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

107.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

110 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

112.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

115 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

117.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

120 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

122.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

125 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

127.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

130 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

132.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

135 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

137.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

140 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

142.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

145 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

147.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

150 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

152.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

155 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

157.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

160 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

162.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

165 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

167.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

170 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

172.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

175 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

177.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

180 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

NVLAP Lab Code 500089-0

Test Report Number: PL08879-001A RESTL-R010 Rev F

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 11 of 13

Integrating Sphere Equipment List

Description Manufacturer Model Serial Number

2M Sphere Everfine 2M 1004156T

CCD Array Spectrometer Otsuka MC-9801 98010360

Programmable AC Source Adaptive FC200 2280220

Power Analyzer Yokogawa WT310 C2QC04045V

Goniophotometer Equipment List

Description Manufacturer Model Serial Number

AC Power Source Chroma 61602 616020002300

Type C Goniophotometer LSI / UL 6440T 6440PN2028

Spectroradiometer Gooch & Housego 770VIS/NIR 12415212

Power Meter Yokogawa WT210 91M945458

Test Methods Used:

Title Description

ANSI C82.77:2002 Harmonic Emission Limits- Related Power Quality Reqt’s for Lighting Equipment

CIE Pub. 13.3:1995 Method of Measuring and Specifying Color Rendering of Light Sources

CIE Pub. 15:2004 Colorimetry

IES LM-58:1994 Spectroradiometric Measurements

IES LM-65:2001 Single-Ended Compact Fluorescent Lamps – Life Test Performance

IES LM-79:2008 Electrical and Photometric Measurements of Solid-State Lighting Products

Reference Standard Used:

Equipment Description

2m Sphere Tungsten Halogen Omni-Directional 75W Calibration Lamp, Serial Number F119

Type C Goniophotometer and Spectrometer

Tungsten Halogen Omni-Directional 500W Calibration Lamp, Serial Numbers 13C069. 13C070, 13C071. For color calibration of spectrometer, 13C074.

NVLAP Lab Code 500089-0

Test Report Number: PL08879-001A RESTL-R010 Rev F

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 12 of 13

Disclaimers:

This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of the federal government.

The results contained in this report pertain only to the tested sample.

This report shall not be reproduced, except in full, without written approval of the RESTL.

*Items marked with a single asterisk are not covered by the NVLAP accreditation.

In the event that the recorded temperature is outside of 25 ± 1˚C, this is considered a non-standard condition.

** In the event that testing is subcontracted, test results in this report marked with the symbol **, or noted as

“Sphere” or “Integrating Sphere”, were performed by the subcontracted laboratory identified in the footer on the

first page of this report. Subcontracted testing is strictly integrating sphere based. All other tests are

performed using a Type C goniophotometer.

The integrating sphere information in the equipment list, report items marked with **, or results specifically

identified as “Sphere” or “Integrating Sphere”, are the actual equipment used, and test results produced, by the

subcontracted laboratory when subcontracting is indicated on the cover page.

Additional Comments:

The photos below are intended to show the orientation and fixturing/set-up of the units under test. These

are critical to understanding the results of the test given the sensitivity of many products and

measurement systems to orientation and set-up considerations, and also for reproducing the conditions of

the test.

Goniophotometer Integrating Sphere

NVLAP Lab Code 500089-0

Test Report Number: PL08879-001A RESTL-R010 Rev F

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 13 of 13

Document Revision History:

Each subsequent revision of this report replaces the preceding report.

Date Rev DCN # Change at the time of this test By Approval

08/05/16 A DMS Origination L. Li C. McLaurin