CRYOGENIC VALVES
T ES
0036
MANAGEMENT SERVICE
W 0 / TRD 100W 0 / TRD 100
2016 - 11
Phone:+90 216 309 72 50 Fax: +90 216 377 98 01Phone:+90 216 309 72 50 Fax: +90 216 377 98 01
YKJ
Application Examples
Yakac kıCryogenic Valves
Design and modification rights are reserved
Phone:+90 216 309 72 50 Fax: +90 216 377 98 01Phone:+90 216 309 72 50 Fax: +90 216 377 98 01
Yakac kıCryogenic Valves
Technical Specifications
Socket welded
Operating Temperature : -196 , +200°C °C
Operating Pressure Max : 63 bar
Size : DN15 - DN25 - DN40 - DN50
Application Areas
Cryogenic lines
LNG (liquified natural gas) industry
Advantages
Quick and easy maintenance
Long life
Stem can be rotated with a low momentum
One piece body casted by precision epoxy casting
Electrostatic painted hand wheel
100% assurance for sealing reliability
Special nut design to prevent the plug damaging KFC ring
Cryogenic Valve Application Areas
Transportation and storage of liquified gases like oxygen,
azote, carbon dioxide, argon, krypton, ethane, methane,
ethylen, nitrogen, LNG, hydrogen.
Design and modification rights are reserved
Phone:+90 216 309 72 50 Fax: +90 216 377 98 01Phone:+90 216 309 72 50 Fax: +90 216 377 98 01
(1) Body
(13) Stud
(6) Nut
(7) Plug
(8) Sliding Washer
(14) Stem
(2) Cover
(18) Stuffing Nut
(22) Hand Wheel Nut
(5) Washer
(3) Plug Teflon Fixing Washer
(4) Plug Teflon
(12) Nut
(20) Hand Wheel
(19) Stuffing Teflon
(21) Lock washer
(16) Gland Retainer
(17) Washer
(15) Stuffing Ring
(24) PTFE Gasket
(25) Graphite Gasket
(26) Stuffing Washer
(9) Setscrew
(11) Cover Gasket
(10) Double Piece Nut
(23) Screw Bushing
Yakac kıCryogenic Valves
Design and modification rights are reserved
Phone:+90 216 309 72 50 Fax: +90 216 377 98 01Phone:+90 216 309 72 50 Fax: +90 216 377 98 01
Cryogenic ValvesDN 15 - 50T p :y e YKJ Socket
DN15-50
PN 63
DIN EN 558/1. serie
Socket according to
- °C + °C196 200
Y .9 .__.00KJ S
Size
Pressure
Dimension
Connection Type
Temperature
Valve Order
MaterialPart Name
1.4408
1.4408
1.4401
KFC+%25 C
1.4401
A2-70
1.4 04 1
1.4401
1.4401
1.4401
Acid PTFE
A2-70
1.4401
1.4401
P.No
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Washer
Plug
Nut
Stud
Stem
Body
Cover
Plug Teflon Fixing Washer
Plug Teflon
Nut
Sliding Washer
Setscrew
Double Piece Nut
Cover Gasket
L
85
115
155
130
H
270
270
270
270
G
97
97
120
120
D
30
42
69
57
d1
22
34,5
61,5
49
10
13
16
13
t1
Dimensions Assembly SizeDN
mm
15
25
50
40
Typeinch
1/2''
1''
2''
1 ''1/2
Graphite
1.4401
1.4401
1.4401
YFC+%25 C
Aluminium
A2-70
A2-70
12 Sn Bronze
PTFE
9655-PR
A2-70
15
16
17
18
19
20
21
22
23
24
25
26
Stuffing Teflon
Lock washer
Stuffing Washer
Stuffing Ring
Gland Retainer
Washer
Stuffing Nut
Hand Wheel
Nut
Screw Bushing
PTFE Gasket
Graphite Gasket
YKJ 15
YKJ 25
YKJ 40
YKJ 50
DIN EN 12760
Design and modification rights are reserved
Phone:+90 216 309 72 50 Fax: +90 216 377 98 01Phone:+90 216 309 72 50 Fax: +90 216 377 98 01
Maintenance Directives
Fluid Types
Allowable fluids are nitrogen, argon, krypton, carbon dioxide, dinitrogen monoxide,chlorinetrifluorinemethane, trifluorinemethane, methane, ethane and ethylene.
Design and modification rights are reserved
Operating Principle
Cryogenic valves are of plug and seat type. The hand wheel is rotated to the right forclosing and to the left for opening.
Important Notes
Fluid type, pressure and temperature specifications should be checked for suitability.
Do not remove the valve from its package till it is necessary to use it.
Keep it dry and prevent from humidity.
Valves are cleaned and the oil remnants are removed to prevent from meeting with oxygen.
Before installation, please remove protection cap if there is any.
The valves should be visually checked before installation. If any damage is observed, theyshould not be assembled.
All parts should be cleaned before installation. No foreign materials should be left in the valve.
Qualified engineers or technicians should be responsible for mounting.
Professional mounting and safety equipment should be used during installation.
Correct mounting position should be selected according to the flow direction shown on valve body.
Should be operated in vertical or horizontal lines.
Painting is not allowed.
Do not apply excessive tightening moment.
Before welding or soldering, the upper cover should be removed.
Thermal expansion of the piping system should be adjusted by expansion joints.
Strainer with filter should be used.
Pay attention to the general directives, safety rules and installation standards of the pipeline.
If the above points are not obeyed:
1. Warranty will be void.
2. Severe injury or death and substantial property loss may be inflicted.
Phone:+90 216 309 72 50 Fax: +90 216 377 98 01Phone:+90 216 309 72 50 Fax: +90 216 377 98 01
Maintenance periods should be determined according to the working conditions.
If the valve has leakage through the stuffing ring (Pos.1), please tighten the stuffing nut(Pos.2) until the leakage disappears. Do not apply excessive moment to the nut.
If leakage is not fixed by just tightening the stufing nut, the valve should be sen toYAKACIK VALF for maintenance and repair.
Only qualified technical staff is allowed for dismounting.
Piping system should be cleaned from aggressive or dangerous remnants.
The valve must be in room temperature.
There should be no fluid left inside the valve.
Parameters Used for Valve Orders
-1 Quantity
-2 Size
-3 Max. Operating Pressure
-4 Max. and Min. Operating Temperature
-5 Connection Type and Norm
-6 Fluid
-7 Actuation Type
Product Code
9SYKJ
Cryogenic Valve
Connection Type
S Socket
Material Code9 Stainless Steel
00
Norms
00 DIN
Dimensions
40
DNDN 25DN 40DN 50
15
YKJ
Design and modification rights are reserved
Maintenance and Repair
Dismounting
It is important that you should specify the parameters stated belowto choose the suitable valve. Please contact us for unclear issues.
VALVE ORDER
You can use the following encoding system in your orders.
Example: YKJ.9S.40.00
Cryogenic Valve, Stainless Steel, Socket, DN40, DIN Norm
Phone:+90 216 309 72 50 Fax: +90 216 377 98 01Phone:+90 216 309 72 50 Fax: +90 216 377 98 01
CE 2354
PED 97/23 EC / III MODULE H
ISO 9001-2008 AD 2000 - W 0
MANUFACTURING QUALIFIED CERTIFICATEQUALITY MANAGEMENT SYSTEM
FIRE SAFE GOSTFIRE SAFE
ALL PRODUCTSBALL VALVES - CAST STEEL PISTON VALVES - CAST STEEL
TPED 99 36
TRANSPORTABLE PRESSURE
Piston Valves DN15 - DN50
Balanced Piston Valves DN65 - DN200
Y SetsX - GT Ring DN15 - DN200
Bellows Sealed Globe Valves DN15 - DN300
Globe Valves DN15 - DN300
Boiler Blowdown Valves DN32 - DN50
T Type Strainers DN15 - DN300
Y Type Strainers DN15 - DN500
Expansion Joints DN25 - DN2500
Manometer Cocks 1/2''
Ball Valves (for natural gas) D 15 - DN 00N 4
Ball Valves Monoball DN15 - DN100
Check Valves DN15 - DN300
Disc Check Valves D 25 - DN100N
Dual Plate Check Valves DN40 - DN400
Butterfly Valves DN32 - DN500
YAKACIK VALF Products
Cryogenic Valves DN15 - DN50
Level Gauges PBR - UPR - UPTY Y Y
Transparent Gauge Glass
Safety Valves DN 20 32 - DN 100 150x x
Fire Hydrants DN80 - DN150
Phone:+90 216 309 72 50 Fax: +90 216 377 98 01Phone:+90 216 309 72 50 Fax: +90 216 377 98 01
Piston Valves DN15 - DN50
Balanced Piston Valves DN65 - DN200
Y SetsX - GT Ring DN15 - DN200
Bellows Sealed Globe Valves DN15 - DN300
Globe Valves DN15 - DN300
Boiler Blowdown Valves DN32 - DN50
T Type Strainers DN15 - DN300
Y Type Strainers DN15 - DN500
Expansion Joints DN25 - DN2500
Manometer Cocks 1/2''
Ball Valves (for natural gas) D 15 - DN 00N 4
Ball Valves Monoball DN15 - DN100
Check Valves
Butterfly Valves DN32 - DN500
YAKACIK VALF Products
Cryogenic Valves DN15 - DN50
Level Gauges PBR - UPR - UPTY Y Y
Transparent Gauge Glass
Fire Hydrants
Disc Check Valves
Dual Plate Check Valves
Safety Valves
DN80 - DN150
DN40 - DN400
DN15 - DN300
D 25 - DN100N
DN 20 32 - DN 100 150x x
Phone:+90 216 309 72 50 Fax: +90 216 377 98 01Phone:+90 216 309 72 50 Fax: +90 216 377 98 01
EQUIPMENT DIRECTIVE
Ball Valves DN15 - DN 004Ball Valves DN15 - DN 004
KocaeliİzmirTrakya
Gsm :Gsm :Gsm :
+90 532 453 25 27+90 533 591 93 98+90 530 370 40 96
İstanbul Deri Organize Sanayi BölgesiTabak Sk. No:4 N7-2 Özel Parsel34956 Tuzla / iSTANBUL / TÜRKİYETel: +90 216 309 72 50 (Pbx) Faks: +90 216 377 98 01www.yakacikvalf.com.tr [email protected]
https://twitter.com/yakacikvalf
YAKACIK VALF A. .SAN. ve TİC. ŞYAKACIK VALF A. .SAN. ve TİC. Ş
https://facebook.com/yakacikvalf
YAKACIK VALF A. .SAN. ve TİC. ŞYAKACIK VALF A. .SAN. ve TİC. Ş
Ankara Gsm :+90 530 497 51 08