+ All Categories
Home > Documents > CSI 9420 Wireless_para Clientes

CSI 9420 Wireless_para Clientes

Date post: 05-Apr-2018
Category:
Upload: micael
View: 224 times
Download: 0 times
Share this document with a friend

of 13

Transcript
  • 7/31/2019 CSI 9420 Wireless_para Clientes

    1/13

    CSI 9420 WirelessMachinery HealthTransmitterWireless HART Connectivity

  • 7/31/2019 CSI 9420 Wireless_para Clientes

    2/13

    Company Confidential

    CSI 9420 Wireless Machinery HealthTransmitterWhile sensor should be

    mounted on the machinebeing monitored, thetransmitter should be mounted

    off the machine.

    Transmitter contains:signal processing,battery, radiocommunication

    Overall Velocity,PeakVue and

    Temperature scalarvalues

    Transmitter can connectto one accelerometer,one accelerometer withembedded temperature,or two accelerometers

  • 7/31/2019 CSI 9420 Wireless_para Clientes

    3/13

    Company Confidential

    300 feet / 100 meters) ) )

    Outputs (scalar values)

    1. Overall Vibration Units: Velocity (in/sec or mm/sec)

    Range: 2 Hz 1000 Hz (per ISO 10816 standard).Comment: Identifies problems like imbalance and looseness

    2. PeakVueVibration Units: Gs PeakRange: 1,000 Hz 20,000 HzComment: Quantify early bearing & gearbox defects

    3. Temperature Range: -30 to +250 F / -34 to +120 CComment: When sensor with embedded temperature used

    CSI 9420 Wireless ApplicationPlace on any equipment

    Mount transmitteraway from machine

    Measurement processing Radio communication Power Module

    1420Smart Wireless Gateway

    CSI 9420Wireless Vibration Transmitter

    Application Works on any equipment Not application specific

    Typical: 10 ft / 3 m

  • 7/31/2019 CSI 9420 Wireless_para Clientes

    4/13

    Company Confidential

    Vibration Measurements MoreThan a Single Overall Value

    Overall Vibration measured in Velocityunits (in/sec)

    2Hz-1000Hz per ISO 10816 standard.Guidelines and tables in velocity units exist toguide plant engineers and maintenance staffson alert limits

    PeakViewTM Overallmeasured in gs pk

    PeakView is a numerical method to detectpeak vibration typically due to rolling elementbearing failures

    1kHz to 20kHz

  • 7/31/2019 CSI 9420 Wireless_para Clientes

    5/13

    Company Confidential

    PeakVue Provides Superior BearingDefect Detection

    PeakVue provides theearliest indication of abearing defect

    Increase in PeakVue valueis proportional to bearing

    defect severity In the late stage bearing

    failure a decrease inPeakVue with acorresponding increaseOverall vibration indicateslate stage bearing failure.

  • 7/31/2019 CSI 9420 Wireless_para Clientes

    6/13

  • 7/31/2019 CSI 9420 Wireless_para Clientes

    7/13

    Company Confidential

    EDDL Enabled Trend of Sensor 1Velocity Value in AMS Device Manager

  • 7/31/2019 CSI 9420 Wireless_para Clientes

    8/13

    Company Confidential

    EDDL Enabled Gauges Show AllProcess Variables in a Single View

  • 7/31/2019 CSI 9420 Wireless_para Clientes

    9/13

    Company Confidential

    Fan Monitoring Application

    Sensor mountedon the bearing.

    Bearing defectdetected withPeakVue

  • 7/31/2019 CSI 9420 Wireless_para Clientes

    10/13

    Company Confidential

    Closer View of Early Stage BearingFault Identified with PeakVueTM

    Bearing defect showsevidence of early-stage

    Impacting.

  • 7/31/2019 CSI 9420 Wireless_para Clientes

    11/13

    Company Confidential

    Get Started With a CSI 9420 SmartPack

    1420Gateway

    CSI 9420Machinery Health

    Transmitters

    5 CSI 9420Transmitters

    1 1420 Gateway

    INSTALL service

    SmartStart service AMS Device

    Manager 5 Tag

    HART Modem

    SmartStart

    INSTALL

  • 7/31/2019 CSI 9420 Wireless_para Clientes

    12/13

    Company Confidential

    CSI 9420 Advantages

    Delivers overall velocity AND PeakVue per sensor

    Overall measurement good down to 2Hz

    Two channel inputs

    Update rate configurable for 1 minute updates

    Delivers data through same network as process valuestemperature, pressure, flow, level

    Can communicate data to multiple hosts simultaneously

    Wireless HART standard exists and will be part of ISA100

    standard.

  • 7/31/2019 CSI 9420 Wireless_para Clientes

    13/13

    Company Confidential


Recommended