CURRENT TRANSDUCERS PHONE (614) 889-6152 TECH. ASSISTANCE (614) 876-8308 FAX # (614) 876-8538 4970 Scioto Darby Rd. Hilliard, Ohio 43026 Div. Morlan & Associates, Inc. WWW.FLEX-CORE.COM sales@flex-core.com 99 CURRENT TRANSDUCERS 3 IN 1 RMS CURRENT TRANSDUCER MODEL 3CTR THREE RMS CURRENT TRANSDUCERS IN ONE ENCLOSURE INPUT Current............................................................ See Table Frequency Range ....................................... 48 to 420Hz Burden ........................................................... 0.4VA F.S. Current Overload 1-10A Range ........................................ 2 X F.S.(cont.) 15-20A Range ................................. 1.25 X F.S.(cont.) 1A Range ................................ 10A (10 sec. transient) All other Ranges ..................... 50A (10 sec. transient) ................................................ 250A (1 sec. transient) Dielectric Test.......(Input/Output/Case) ................... 2200Vac LOAD LINE All Dimensions In Inches OUTPUT Output Ripple................................................ <1.0% F.S. Response (90%) ................................................. 100ms Output Loading (Ω) 0-1mA .............................................................. 0-10K 0-10Vdc, 0-5Vdc ............................................ 2K min. 4-20mA ............................................................. 0-500 Field Adjustable Cal.............................................. +10% ACCURACY ................................. +0.25% F.S. at 60Hz ............. Includes effects of linearity and repeatability. ............................... +0.5% F.S. over frequency range Temperature Effect...........(-20°C to +60°C) ...... +1.0% Rdg. Instrument Power (Std.) ......85-265Vac, 48-420Hz, 5VA or .................................................... 110-370Vdc, 5VA Weight .............................................................. 2.5 Lbs. FEATURES APPLICATIONS SPECIFICATIONS DIMENSIONS CONNECTION DIAGRAMS USING CURRENT TRANSFORMERS USING INTERNAL CURRENT SENSORS 1 6 5 4 3 2 11 10 9 8 7 12 6a 12a L2 L3 L1 OUTPUT L1 - + - + OUTPUT L3 - + L2 OUTPUT TERMINALS 1, 3, AND 5 ARE INTERNALLY COMMON INST POWER (+) (-) L1 L3 L2 L1 OUTPUT - + 1 2 L2 OUTPUT - + L3 OUTPUT - + (+) (-) 10 6a 3 4 5 6 8 7 9 11 12 12a INST PWR LOAD LINE 1.50 4.75 0.25 0.25 3.63 CASE HEIGHT 6.63" DIA 0.38 (2 PLCS) DIA 0.19 (4 PLCS) 12 34 56 CAL ZERO 6a 7 8 9 10 12a 12 11 STANDARD OUTPUTS MODEL 3CTR- 001E 005E 010E 015E 020E 0 to 1.0A 0 to 5.0A 0 to 10.0A 0 to 15.0A 0 to 20.0A AC AMPS INPUT 001B 005B 010B 015B 020B 001D 005D 010D 015D 020D 0-1mAdc 4-20mAdc 0-10Vdc 0-5Vdc 001X5 005X5 010X5 015X5 020X5 Example: 5Aac Input with 0-10Vdc Output. 3CTR-005D ORDERING INFORMATION Accurate measurement of the true RMS value of input signals over a wide frequency range. Accurate to 0.25% Full Scale Designed to withstand motor start-up transients. Input/output isolation. Designed for use in applications where measurement of non-sinusoidal waveforms is required. Designed for use on three-phase systems, but may also be used to monitor three single phase circuits where panel space is limited. Use with current transformers for high current applications.
Transcript
  • CURRENT TRANSDUCERS

    PHONE (614) 889-6152TECH. ASSISTANCE (614) 876-8308

    FAX # (614) 876-85384970 Scioto Darby Rd. Hilliard, Ohio 43026Div. Morlan & Associates, Inc.

    [email protected]

    99

    CU

    RR

    EN

    T T

    RA

    NS

    DU

    CE

    RS

    3 IN 1 RMS CURRENT TRANSDUCER MODEL 3CTRTHREE RMS CURRENT TRANSDUCERS IN ONE ENCLOSURE

    INPUTCurrent ............................................................ See TableFrequency Range ....................................... 48 to 420HzBurden ........................................................... 0.4VA F.S.Current Overload

    1-10A Range ........................................ 2 X F.S.(cont.)15-20A Range ................................. 1.25 X F.S.(cont.)1A Range ................................10A (10 sec. transient)All other Ranges .....................50A (10 sec. transient) ................................................250A (1 sec. transient)

    Dielectric Test.......(Input/Output/Case) ...................2200Vac

    LOADLINE

    All Dimensions In Inches

    OUTPUTOutput Ripple ................................................


Recommended