Product Release Letter For further information please contact your local AVEVA support office, which can be found at http://support.aveva.com This document has been prepared and approved by the following: Job Title Name Product Manager Peter Brunning Test Manager John Henderson Head of Product Gavin Watton GSC Managers Ricky Padhiar, John Reynard File: d51925.doc Last saved: 14-Jul-2010 Copyright 2010 AVEVA Solutions Limited Page 1 of 13 AVEVA PDMS 12.0.SP6 Full Release 51925 Windows XP and Windows 7 This letter introduces and describes this release, which is supported on the indicated platform(s). This Release Contains A full release of AVEVA PDMS, which replaces the full release 51877 AVEVA PDMS 12.0.SP5. The separately licensed products or product components installable from or upgraded by this release are as follows: Product Code Product Name Version Number V01FN240 AVEVA PDMS 12.0.SP6 V00FN243 AVEVA QUERY 12.0.SP6 V00FN248 AVEVA Laser Model Interface 12.0.SP6 V00FN250 AVEVA Final Designer 1.3 SP2 V00FN266 AVEVA Schematic Model Manager 12.0.SP6 V00FN267 AVEVA Schematic 3D Integrator 12.0.SP6 V00FN268 AVEVA Cable Design 12.0.SP6 V00FN277 AVEVA Diagrams 12.0.SP6 V30FN800 AVEVA Pipe Stress Interface 12.0.SP6 V10FN805 AVEVA Multi Discipline Supports 12.0.SP6 V10FN806 AVEVA Area Based ADP 12.0.SP6 V10FN811 AVEVA ExPLANT-I 1.4.SP1 V10FN825 AVEVA ExPLANT-A 1.1.SP1 V00FN826 AVEVA Nuclear Concrete Design 12.0.SP6 V00FN827 AVEVA Nuclear Room Manager 12.0.SP6 V00FN829 AVEVA Nuclear Concrete Quantities 12.0.SP6 V00FN977 AVEVA Mechanical Equipment Interface Import 12.0.SP6 V00FN978 AVEVA Mechanical Equipment Interface Export 12.0.SP6 The installer for PDMS and the associated products listed above will install software and documentation see notes below. You are only entitled to run those specified in your contract and for which you have valid licenses.
Transcript
Page 1: d51925

Product Release Letter

For further information please contact your local AVEVA support office, which can be found at http://support.aveva.com

This document has been prepared and approved by the following:

Job Title Name

Product Manager Peter Brunning

Test Manager John Henderson

Head of Product Gavin Watton

GSC Managers Ricky Padhiar, John Reynard

File: d51925.doc

Last saved: 14-Jul-2010 Copyright 2010 AVEVA Solutions Limited Page 1 of 13

AVEVA PDMS 12.0.SP6

Full Release 51925

Windows XP and Windows 7 This letter introduces and describes this release, which is supported on the indicated platform(s).

This Release Contains

A full release of AVEVA PDMS, which replaces the full release 51877 AVEVA PDMS 12.0.SP5.

The separately licensed products or product components installable from or upgraded by this release are as follows:

Product

Code Product Name

Version

Number

V01FN240 AVEVA PDMS 12.0.SP6

V00FN243 AVEVA QUERY 12.0.SP6

V00FN248 AVEVA Laser Model Interface 12.0.SP6

V00FN250 AVEVA Final Designer 1.3 SP2

V00FN266 AVEVA Schematic Model Manager 12.0.SP6

V00FN267 AVEVA Schematic 3D Integrator 12.0.SP6

V00FN268 AVEVA Cable Design 12.0.SP6

V00FN277 AVEVA Diagrams 12.0.SP6

V30FN800 AVEVA Pipe Stress Interface 12.0.SP6

V10FN805 AVEVA Multi Discipline Supports 12.0.SP6

V10FN806 AVEVA Area Based ADP 12.0.SP6

V10FN811 AVEVA ExPLANT-I 1.4.SP1

V10FN825 AVEVA ExPLANT-A 1.1.SP1

V00FN826 AVEVA Nuclear Concrete Design 12.0.SP6

V00FN827 AVEVA Nuclear Room Manager 12.0.SP6

V00FN829 AVEVA Nuclear Concrete Quantities 12.0.SP6

V00FN977 AVEVA Mechanical Equipment Interface – Import 12.0.SP6

V00FN978 AVEVA Mechanical Equipment Interface – Export 12.0.SP6

The installer for PDMS and the associated products listed above will install software and documentation – see notes below. You are only entitled to run those specified in your contract and for which you have valid licenses.

Page 2: d51925

Product Release Letter

d51925.doc 14-Jul-2010 Copyright 2010 AVEVA Solutions Limited Page 2 of 13

Please note that use of the schematics database requires a new license feature from version 12.0.SP5. This has been included with the relevant schematics product licenses issued after September 2009. Existing license servers will need their license file refreshed to enable the schematics products to function. Please note the change of operating system and licence server specified below. A major update

for this service pack is the provision of support for Windows 7; as a result, Windows 2000 is no

longer supported. At this release, a single 32-bit installation is supplied for use on both 32- and 64-bit variants of Windows 7 (Professional or Enterprise).

Prerequisite for this release - operating system:

Build Operating System Windows Server 2003 R2 (Service Pack 2)

Minimum Supported O/S Version (for each supported platform)

Windows XP Service Pack 2 or Windows 7 (32- or 64-bit) - with Microsoft .NET Framework 3.5 (supplied) N.B. Windows 2000 is no longer supported

Mandatory O/S Patches (for each supported platform)

XP: Service Pack 2 or 3 The use of SP3 is recommended as Microsoft drops support for SP2 in July 2010

Please note that recommended/supported hardware and software configurations are constantly subject to review, so please consult the AVEVA support web pages for the latest recommendations.

Prerequisite for this release - products:

Flexman 5 (32-bit or 64-bit as appropriate) and an appropriate Flexman license (License files generated from June 2010 onwards are compatible with Flexman 5 as well as Flexman 3 & 4). For further details of Flexman License Server 5, please see http://support.aveva.com – Licensing section. Microsoft Office 2003 or 2007 is required for some functions:

Optimum operation of the AVEVA Design Platform GUI requires Arial Unicode MS font, supplied with Microsoft Office (2000 onwards) and also with Microsoft Office Visio.

Microsoft Office Excel import requires “.NET Programmability Support” enabled when Office is installed. This can be found under “Advanced customization of applications” and installs the Microsoft.Office.Interop.Excel.dll; without this, Excel import will not work.

Microsoft Office Visio 2007 (Standard edition) is required for AVEVA Diagrams and for viewing the Schematic model in AVEVA Schematic 3D Integrator. Adobe SVG Viewer 3.02 is required for AVEVA Schematic 3D Integrator and AVEVA P&ID Manager. It may be downloaded from: http://www.adobe.com/svg/viewer/install/old.html

For full details, please refer to the AVEVA Plant 12.0 Minimum System Requirements manual.

AVEVA Licensing Library

Products in this release include the AVEVA licensing library cadcflex 5.2; please refer to the Flexman Installation and Configuration Guide or the Licensing section of the AVEVA support website http://support.aveva.com for a list of licensing features supported by this version of cadcflex.

Page 3: d51925

Product Release Letter

d51925.doc 14-Jul-2010 Copyright 2010 AVEVA Solutions Limited Page 3 of 13

Works (is compatible) with:

Other AVEVA Plant (12 series) products on this DVDR

AVEVA Model Management 12.0.SP4, Clash Manager 12.0.SP4

AVEVA NET Gateway 1.1

AVEVA PDMS VPRM Gateway 5.1

For full details, please see the compatibility matrix on the http://support.aveva.com/support/.

Supersedes:

This release supersedes the previous full release 51877 AVEVA PDMS 12.0.SP5.

To install product release:

Please read the installation guide, which is visible on the DVD and will be placed under the product\manuals folder once the product install (setup.exe) has been run. Please note that there is now a combined installer for PDMS and the associated products listed above. This can be configured by using the check boxes to install a selection of products. Control Panel > Add or Remove Programs may subsequently be used to add additional ones or remove them at a later date. Installations using setup.exe will by default install to C:\. The individual .msi files will by default use the drive with most free space. More details are given in the user bulletin. If you require sample PDMS projects, please ensure that you check the „PDMS models‟ box. If you require the product documentation in PDF format, that is also a separate tick-box. The Global tick-box installs the necessary support for Global use of PDMS. There is a separate installer for the Global server; please note that there is no longer a tick-box option to install it with PDMS.

PDMS Models – revised deployment

These are now distributed and installed using zipped files for efficiency. Once they have been unzipped, the evars.bat file should also be edited appropriately. The line to edit is:

set projects_dir=[PathToMyModels]

This also means that such models will not be repaired or uninstalled by this installation or that of a subsequent fix release.

Plot Utilities – revised deployment

The following plot files have been moved to C:\ProgramFiles\Common Files\Aveva Shared\Plot\ : PLOTDRIVERS PlotServ.exe PlotServCmd.exe PlotViewer.exe PlotViewer.hlp PlotViewer.tlb

Diagrams upgrade from Service Pack 4 to later service packs – additional

information

This applies to those who have Diagrams created at PDMS 12.0.SP4 or earlier releases, including those supplied in the Sample project. See also User Bulletin section 2.6.1.

Page 4: d51925

Product Release Letter

d51925.doc 14-Jul-2010 Copyright 2010 AVEVA Solutions Limited Page 4 of 13

There is a change at SP4 in the method used to reference from the Visio drawing to the database. Any diagrams created in earlier versions will be automatically upgraded when opened. After that, they need to be saved again, notably before using Project Copy.

Note for Final Designer:

Sample projects, revised for Final Designer, are installed with the product but not activated, as they may not work well with all other applications. To activate them, please revise your project directory environment variable (usually set in evars.bat) from:

set projects_dir=%pdms_installed_dir%\project

to: set projects_dir=%pdms_installed_dir%\project\fd

Note for developers of .NET assemblies

In order to allow these applications to work through service pack and fix release updates, the service pack and patch versions have been removed from all published .NET interface assemblies and PMLNet.dll. The assembly version for these is 12.0.0.0 for all versions of PDMS 12.0, for SP4 and later (the file version contains the full version number including the service pack and patch). If you have written PML.NET applications for PDMS 12.0.SP3 or earlier releases, please refer to the PDMS User Bulletin - section 23.1.1 Notes for developers of .NET assemblies.

Global Deployment – Rebranded to “Global Server”

To help distinguish the Global Client from the Global Server product, the dialogs in the Global installation now refer to themselves as the “Global Server”, and the installation folder now defaults to: C:\AVEVA\GlobalServer12.0.SP6\

Page 5: d51925

Product Release Letter

d51925.doc 14-Jul-2010 Copyright 2010 AVEVA Solutions Limited Page 5 of 13

First released on:

This product release is first available on AVEVA DVD PDMS 12.0.SP6 and associated products,

release number 41108.

List of Enhancements

This release includes many functional enhancements, including the following:

Description

For details, please refer to the updated PDMS User Bulletin.

List of Fault Corrections

This release addresses many defect reports, not all of which are listed. Incident

number

Defect

number Description

P-3660 Cats & Specs: Format exception error entering special characters in Size range table

P-8264 DRAFT: Corrupt Cyrillic DXF output when using TrueType text

DFN 2847 P-8950 Query manuals updated

DFN 11557 HPD 36211 P-10189 Enhancements to ISODRAFT

DFN 11648 HPD 36938 P-10241 Item code (UDA) on IDF does not appear in record 20

5365 P-12355 Structures: Availability of non-penetration managed holes to other design disciplines

P-14003 Hole Management modified for Global operation

P-14081 Structures: Unhandled Exception message when moving Current Vertex for Platform

8145 P-16666 Design Representation Issue

P-17455 Diagrams: Automatically add Tee on dragging end of one connector onto another

P-18246 Search utility filters value field not updated correctly

P-18492 Diagrams: Cursor is changed to hour glass after closing some standard Visio dialogs

P-18671 Create a FIXING as a member of PNOD; FIXING is displayed in wrong place in Review

P-18748 3D view not refreshed, element not removed, after Un-doing Copy element

7118 P-19985 Diagrams: When fitting is inserted, Question dialog info should have DTXR field

P-20451 Cable Design: STAREF/ENDREF of EXTGEO for Cable displays RNODE instead of EQUI name and displays incorrect CBRNLS

P-20540 Cable Design: Autoroute should minimise free route rather than route on CableWay

P-21429 Testing for unset values in collections

P-21768 Diagrams: Replace Shapes - Stencils

P-22132 Diagrams: Consistency check should report nested shapes

14282 P-22886 Spooler: hangs when the customer's automatic spooling macro run.

P-24126 Diagrams: Annotation format should support text formatting functions

15778 P-24572 Unmark PDMS Branches

P-24583 Isodraft: Error message “(61,129) – Options save aborted while creating Option File

13000 P-24917 Cable Design: when Auto Route performed, cable cannot be routed along the provided CW branch

15165 P-24960 Cabletray: System crash using Modify > Component > Connection ref. on Cross with no connection refs

16633 P-24967 Cats & Specs: Unable to switch to a Engineering view on the Modify>Spec form.

16474 P-25041 ExPLANT License warning causes error

17089 P-25205 Diagrams: Old version shapes - menu commands

Page 6: d51925

Product Release Letter

d51925.doc 14-Jul-2010 Copyright 2010 AVEVA Solutions Limited Page 6 of 13

17058 P-25514 Diagrams: Commands from canvas

17314 P-25789 Representation Rules in Design enhancement to available types required

17489 P-25866 Diagrams: Cable EQUI copy shape

15167 P-25875 Cabletray: Connection References - Variable not set

P-25886 Cable Design: auto routing should use HATTA and TATTA instead RNODE

17588 P-25931 Hiding APPLDW, ASSOWL, ASDFWL, etc. elements in Design Explorer

17698 P-25977 Equipment application, Modify main menu, Angle... entry

17405 P-25991 Cats & Specs: cannot add to spec

P-26269 The querying of C of G produces an incorrect result

P-26311 Weld missing on the isometric whereas present in the spool

P-26312 Isodraft: Reading from properties db from option file

P-26313 Weld not shown on isometric if ATTA positioned at P-point of TEE

P-26314 Isodraft: Weld missing if Spec has SHOP flag set to FALS rather than FALSE.

P-26315 Incorrect weld number on spldrg bypass loop

P-26482 Consistency Check

18351 P-26538 Cats & Specs: replace Edit Ref/Attributes by Edit References on the Modify>Spec form

18394 P-26617 Diagrams: Upgrade Drawing

16641 P-26705 Update of Pipe Specifications in Paragon incorrectly updating data

P-26757 Sch. M M: Unhandled Exception errors when DAC is ON for Schematic Model Manager

P-26797 Clashing of GENPRI element fails to report any clash

12393 P-27086 Diagrams: Unable to create Offset and Plate HBAV Element types

P-27092 SQL Direct: installation Guide needs to be updated. Displays incorrect snapshots

P-27094 SQL Direct Installation guide displays incorrect Installation window snapshots

17889 P-27119 Diagrams: Element SCEQUI do not define in drawing

19153 P-27149 Cats & Specs: remove Wall thickness column, grid insertion type from Nominal Bore range table

19322 P-27380 P/A: SC Status control doesn't work with UDETS - Status Definition assigned to UDET causes error

P-27440 Cats & Specs: Documentation of Sphere incorrect

19367 P-27477 Diagrams: More than 7 letters input for SCSTYPE attribute

P-27617 Weld not shown on Spool Drawing isometric if ATTA positioned at P-point of ELBOW

P-27619 Spooler: Extra joint numbers added when Hubbed Flange are used

P-27620 Spooler: Missing ATTA in spool drawing when ATTA is at start of the first branch

P-27621 MDS Adjustable Plate AC67 - Missing number tag on Isos - ITEM NO. 4 "FITTING No."

P-27623 Kink in isometric when produced from spldrg.

P-27624 Isodraft: Wrong representation of branch offset connected to elbows on sloped line

P-27625 Wrong weight on isometric

P-27626 Part of MTO takeoff missing when Iso has Field fit Weld and Flange set to Shop False

HPD 39978 P-27627 Isodraft: Incorrect Piece No with Branch's MTOH off(Set-on TEE Connection)

P-27650 Isodraft: Wrong coordinates of pipe head when pipe starts with a blind flange

P-27652 Isodraft: Pcom Skey 'BAFL' Block - Angle, does not display correctly when a small angle is app

P-27654 Isodraft: change highlighting causes wrong dimension

P-27655 Isodraft : Eccentric reducers.

HPD 38034 P-27656 Isodraft cannot output isometrics on pipe level with bypass line which contains PCOMs

P-27660 Isodraft: Correct the placement of the Bulkhead ATEXTs.

19530 P-27822 Cabling: Loading some forms very slow.

P-27961 Sch. M M: Check CE does not report inconsistent CRFA on SCFITT

9951 P-27965 Cats & Specs: Autonaming

16526 P-27979 Diagrams: element size change cause renaming of all SCNOZZ

P-27999 Diagrams: Text splitting functions in annotation format

P-28024 Isodraft: Missing weights for MTOR components when it's pipe

P-28028 DRAFT: Vertical Alignment not working in s/r GDFTPA (Wigwam)

P-28083 Sch. 3D I: Not possible to change view limits in Integrator compare 3D view

Page 7: d51925

Product Release Letter

d51925.doc 14-Jul-2010 Copyright 2010 AVEVA Solutions Limited Page 7 of 13

P-28107 Isodraft: Fatal error when on entry when multiple DICT DBs are in MDB

P-28164 Bending machine radius errors should not appear if BendMacReference unset at zone

18282 P-28172 Weight and CofG cannot be calculated for SCTN

P-28180 Isodraft: Why aren’t the Lugs (Olets) numbered on the isometric?

20063 P-28212 MEI: Imported STEP objects loading very slowly

P-28255 Isodraft: Wrong bolt length generated with wafer components

P-28256 Isodraft: weight of pipe should not change if length changed between Metric & Imperial

HPD 40322 P-28257 Wrong Isos created due to :UDAs with text

P-28258 Isodraft: Missing weld number for an additional weld on a trunnion

P-28261 AttributeLikeFilter has incorrect operation

P-28262 Paragon: Copy button required for Structural geometry components and Plines on Model View

P-28345 Sch. 3D I: Schematic grid not being populated when picking object at bottom of list

P-28382 Set View limits to Grid only works for form !!GPH3DDESIGN1

P-28383 Saving purposes to a defined file from define purpose form fails

18761 P-28397 DRAFT: OUTL primitive

19872 P-28398 Diagrams: We cannot extract "N1" from original SCNOZZ name.

P-28406 Cable Design: System pull down required

P-28408 Paragon: Offset attributes for SPVE elements not editable from the Model View form

20732 P-28411 DRAFT: Crash adding ASL element to viewlist

20722 P-28417 Negative values for X/Y-Offset of primitives cannot be entered

18458 P-28421 Performance differences between COLLECT and !!CollectAllFor()

18110 P-28422 Structures: Sort order for Structural Profiles in Specification forms

P-28432 Global: De-allocation will not start.

P-28445 Auto Clash stops working following Utilities > Clashes…

P-28446 Problem with Justification gadget on Joint Specification form.

20158 P-28454 Choice not available error when choice is available in spec (H/T Bore will not be set when we BUILD several pipes at one time)

P-28460 Sch. M M: Edit Members: Attribute update errors are not shown

P-28461 DARS interface does not support usernames with lower-case letters

P-28462 Sch. M M: Edit Members: Grid layout and Autofilters are unexpectedly being reset

P-28465 Sch. M M: Edit Members: Selected row becomes unselected after activating DB order button

P-28466 Sch. M M: Edit Members: Filter function works in a non-intuitive way

P-28477 Cable: The graphical display of the Offset for a Gap RNODE is incorrect

P-28478 Cable Design: Not possible to use any new non standard width parameter for cable way material dressing

P-28480 Wall thickness pseudo attributes

P-28481 Cable Design: Missing a part of cable routing

P-28493 Modifying Cableway material is very clumsy and time consuming

P-28494 Cable Design: Straights overlap when using Straight between Picked Component with modified components

P-28496 Sch. M M: Check CE on schematic data should report inconsistent flows and refs

20513 P-28510 ExPLANT-A: license warning prevents export

P-28525 Sch. M M: Import option in the General tab of the Project options window does not function properly

9754 P-28544 Cable Design: a route node cannot register the cable

21106 P-28583 Cable Design: when modify CW by model editor, the model editor cannot locate on CW

P-28596 Template Member Parameters form does not navigate to created primitives.

P-28598 Equipment: Attributes form displays False for attributes which are of reference type.

21140 P-28603 Cable Design: Two CWB cannot connect

21134 P-28605 Cable Design: Create route point, cable system appear following error information

20321 P-28623 Quick Router Connect and Complete does not set TCON

P-28628 selection by drawlist in list form

Page 8: d51925

Product Release Letter

d51925.doc 14-Jul-2010 Copyright 2010 AVEVA Solutions Limited Page 8 of 13

P-28629 DRAFT: Russian text DGN output is sometimes garbled (native fonts)

P-28675 Sch. 3D I: Set spec change for Router

P-28717 Diagrams: Support for 3-state checkbox needs to be added to the AVEVA Grid Control

P-28726 Router hangs routing a pipe created from P&ID Integrator that has a tee

P-28731 Form changes for free hole creation

P-28732 Hole Association Manager form has incorrect radio button caption.

P-28734 PIPE Spec Break cannot be reproduced by Router

P-28735 Connecting to Nozzles is not possible if a nozzle in an Equip has unknown ref.

21359 P-28738 Cats & Specs: Part Family form inconsistent with attributes of CABD element

21362 P-28739 Cats & Specs: change order of the selectors for STYP and SHOP in standard headings.

P-28822 SQL direct server crashes when connecting unless workaround setting applied

21443 P-28826 Sch. M M: Incorrect Help Text in line list Configuration Form

P-28911 PDMS Server will not stop even after closing SQL Direct

P-28920 Lexicon Window Layouts unhappy

21485 P-28923 Nuclear Concrete Design: Modification positive volume in general HOLE

P-28929 PDMS Grid control AfterSelectChange event should return data for cell click event

P-28934 Programmatical method required for reordering columns in the PDMS Grid

9075 P-28946 Piping component creation within Design

21804 P-28984 Nuclear Concrete Design: Imperial units not behaving properly in splitting walls

P-28993 Diagrams: Invalid References in SCHEMATIC/DIAGRAMS

P-29018 OUTPUT command produces duplicate entries

21806 P-29031 HVAC: Wrong assignment of design parameters on circular three-way fittings

21792 P-29087 Diagrams: including the PMG schematic model Mgr UDA cause crash on re-edit Master

P-29109 Sch. M M: Edit Members function: Principle for storing Saved Layouts needs changing

P-29111 PDMS: Preserve feedback colors across grid refresh

P-29132 INCLUDE ACROSSDB sets certain external references on moved elements to nulref

P-29133 Diagrams: Auto Connect option in SMV

P-29156 Improve Explorer addin start up performance

P-29168 Facility to retrieve the filtered rows

P-29199 Sch. M M: Remove Schematic Model Viewer menu options

P-29209 Cats & Specs: Specifications in /PIPECATA have SHOP before STYP in the selectors.

19350 P-29228 DRAFT: “DESADD” and “GENERATE MODEL" performance difference

P-29262 Piping Head and Tail positions

P-29263 Default Temp of Piping Form should be -100000

P-29264 Pipe creation form does not identify the current branch graphically.

P-29265 Create > Pipe, should display new form

P-29266 Update "Pipe Modification" form in order to be able to change from a Pipe to another

P-29269 Ability to copy a head and tail position on the branch modify form

P-29270 Spec/bore change utility does not change branch HSTU, though it appears to on form

P-29272 Insert component error in Design Pipework.

P-29273 Component creation does not insert components in the correct place near ATTAs

P-29274 Creating the first component in a branch no longer works in component creation.

P-29275 Expanding the pipe assembly hierarchy in the Pipe Assembly Manager

P-29276 Pipe assemblies do not work if one or more of the components from a different spec.

P-29278 Piping Assembly Rules - slash is not added before Specification on STYPE rules

P-29279 automatically orientate branch head and tail to remove dotted line

P-29280 On Pipework Application, it is not modified.

P-29281 ABA defaults form shows a sad face if libraries are missing but does not say which ones

P-29284 Sch. M M: HCref of SCSEG in SWS-002 fails to set back if SWS-001 is deleted re-imported

P-29291 Diagrams: Icons in Shape menu.

P-29315 Tool Tip changes when cell is in update mode

P-29408 Sch. 3D I: Show numbers of errors, warnings & messages, for each item in compare report tree

P-29475 Integrator user guide database access statement is wrong especially regarding global

Page 9: d51925

Product Release Letter

d51925.doc 14-Jul-2010 Copyright 2010 AVEVA Solutions Limited Page 9 of 13

P-29531 Global: Improved 11.6 to 12.0 upgrade script for satellites

21052 P-29539 PDMS 3D View Clipping with Capped is not working properly

P-29540 Schematic model manager gives an exception at start-up

22167 P-29624 Spooler: 'Spooling add' command causes memory leak and slowdown

P-29626 MDS: Error message “(2,751) Variable! NAMEOFMEM does not exist” is displayed when the user deletes an M

P-29671 Diagrams: Instrumentation Data Update option is not visible

P-29677, P-29678 PEROPS addition to status control manual

P-29680 Sch. M M: Delete Option enabled on right click context menu with Schematic World as CE i

P-29683 Sch. M M: Edit > UNDO functionality does not work

P-29685 Diagrams: Consistency Check window not turning to blank when elements consistent

P-29714 Equipment: Remove Last Definition button overlaps OK button in the Create Extrusion

P-29719 Cats & Specs: Error message “(2,752) Array element 8 does not exist” shown on importing the edited file in Model View form

P-29727 DRAFT: Section planes fail to move to the P-point selection with Align With feature

P-29741 P/A: SC status controller causes crash on undo

P-29752 Reference List gets sorted by Name on mouse-over of “Arrange By >” context menu item.

21480 P-29757 Cable Design: Automatic Dressing should take Bend Radius info from POINTR elements

21482 P-29758 Cable Design: RATTA requires additional info so that correct material component can be selected

P-29762 Diagrams: Events problem

P-29763 Cats & Specs: DESC entered for Parameter1 disappears on Clicking on New button in Model view form.

P-29786 UNDO related problems with DB_RawChanges, improve robustness to error conditions

P-29789 Sch. M M: Need to consider only the SCVALV elements having “INST” as GTYPE

P-29790 Sch. M M: Status check box status on partial update from Inst.

P-29812 Draft performance is slow when navigating between elements

P-29816 DRAFT: background Process manager crashes if the install path is in c:\program files

P-29821 String object does not work correctly when length of string greater than 256 characters

18995 P-29829 Diagrams: Incorrect translation of Chinese characters from Lexicon UDA definition

P-29832 Unhandled exception while switching from Design to Schematic Model Manager

P-29839 INCLUDE ACROSSDB sets certain external references on moved elements to nulref (again)

P-29842 Message 'make.exe encountered problem' is displayed when creating project

P-29845 DRAFT: error (2,752) on the user defined linear styles form (Isodraft libs)

P-29846 Unhandled Exception when PipeAssemblyManager Form is opened after closing PreviewIsometricDrwg

P-29858 Diagrams: Unhandled exception error appears selecting Released radio button in Visualize Release

23142 P-29863 DRAFT: Print Sketch on PipeSketch form

P-29868 DRAFT: Error message displayed while recreating Shapes in Draft Module.

P-29874 REF attribute supported instead of DBREF attribute on Navigator

P-29876 DICE: Runtime error when performing project-wide Integrity check, foreign database excluded

23147 P-29885 Sch. M M: Edit Member - Added column is removed when saved work is applied

23099 P-29891 Global: Primary Location Form is not displaying all the locations when in Modify Database Mode

HPD 36076 DFN 11541 P-29901 Spooler: Unhandled Exception error for Spools with more than 500 items

P-29902 Runtime error displayed while executing the newly created encrypted macro file in Admin.

Page 10: d51925

Product Release Letter

d51925.doc 14-Jul-2010 Copyright 2010 AVEVA Solutions Limited Page 10 of 13

23220 P-29932 Piping: Error message when deleting a Managed Hole

P-29933 Structures: Inappropriate error msg displayed while creating second sectn with Primary node set to on

P-29934 Sch. M M: Att Changes made in Instmentn not reflected in SCHE DB after performing refresh func

P-29935 Admin: Unhandled exception on selecting Aveva.Pdms.Database.xml under Customize Resource

P-29936 Sch. 3D I: Unhandled error appears on editing the grid value in the 3DIntegrator main table

P-29938 Sch. M M: Inconsistency in Accept All function provided on main menu of Inst Data Update Addin

P-29943 Design Explorer view scrolling problem

P-29947 Piping: No Bore listed for the Default Spec PSI-SPEC in Bore drop-down list in Create Pipe form.

P-29951 Sch. M M: AI data import failure for duplicate TagNo

P-29963 The color of the grid fails to change on changing the color in Display Gridlines form.

P-29977 Cable: Selecting value in Penetration drop down in Cable Hole Mgt Defn form leads to Splash Err

P-29982 Sch. 3D I: Link EQUIPMENT header displays‘Select 3D Element’ instead of ‘Select Schematic Element'

P-29983 Sch. 3D I: Unhandled exception appears while linking the 3D equipment to Schematic equipment.

P-29988 Global: Extract Data Control form gets disabled when FLUSH option is selected.

22671 P-29995 Nuclear Concrete Quantities: Compatibility problem with %PRJDFLTS%

23307 P-30001 Nuclear Concrete Design: "Repeat" button to create a FLOOR, if 2D Contour Editor is set to "Modify" it will modify origin

23338 P-30007 Problem with imperial units in search utility form

P-30014 Cable Design: Cable Primary System (Consistency)

P-30021 Store CAF SettingsManager settings in a version specific directory.

P-30026 Cats & Specs: Appln turns to Not Responding mode on selecting Utilities > Autonaming > CE Offspring.

P-30028 Cable Design: Error message is displayed while entering the name for the copied cableway elements.

23481 P-30107 Sch. M M: Edit Member - Error message displayed when Manage grid layouts is selected.

P-30112 Piping: Err msg'(2,754) Argument 1 to ATTRIBUTE is unset' is displayed selecting Bend type as BB

P-30121 Sch. 3D I: Application crashes while unlinking the SCPLIN when Link SCPLIN window is opened.

18948 P-30129 Draft: Matchline text broken in imperial units

P-30133 Using "Align with feature" functionality from Model Editor crashes

P-30140 Sch. M M: First row of attribute details is shown accepted when one instrument accepted

P-30148 Performance of context menu display in Explorer improved

P-30159 Piping: Unhandled exception msg is displayed on clicking on Save button in Log Viewer form.

P-30166 crash starting PDMS application following Admin password change control

P-30174 Error message is displayed while clicking on the Apply Representation Rule Set button.

P-30176 Sch. 3D I: Unhandled Error after selecting Save icon in Competition Category window.

P-30224 Diagrams: Inconsistent behaviour on starting DiagramsCadExportAddin

23656 P-30232 Equipment: Modifications to REVO loop are undone when Apply button clicked.

P-30245 DRAFT: Problem with Styles & Colours at SLABs

23659 P-30250 Structures: Modify>Sections>Mitre Ends command is not working correctly

23647 P-30275 Equipment : Primitives invalid data entries do not return to previous value

P-30278 Cats & Specs: Unhandled error appears after selecting Print Preview from the context

Page 11: d51925

Product Release Letter

d51925.doc 14-Jul-2010 Copyright 2010 AVEVA Solutions Limited Page 11 of 13

menu in status

P-30283 Design Explorer fails to open again, after closing it by using Close button

P-30297 Panel is not clashing with Pipe when it should

23695 P-30304 Graphical Select does not select Branch Tail

23802 P-30339 Cats & Specs: Bolt Table Utility form

23761 P-30365 Cable: Modify route point, cable system appear following error information

23808 P-30366 Sch. M M: SCBRAN name not correctly uploaded on import

P-30413 MDS: Error message “(2,752) Array element 1 does not exist” appears on selecting ancillary AN19

P-30425 Equipment: Error 'Element does not have VDISTA' displayed on selecting Modify Properties for Equip

P-30427 Exception populating grid in draft "user defined linear styles" form

23913 P-30433 12.SP6#4 Deleting a PDMS user but not the NT gives Database error 10

P-30434 Cable: performance problem with moving the equipment

P-30435 Piping: Creation of component against the flow near the ATTA does not work correctly

23921 P-30441 Fatal error related to NT Authentication, when PDMS users deleted

23339 P-30446 Fatal Error - Using user defined nominal Bore & Large Bore Value & Inch Bore Setting

P-30449 Global: Working Extract Number Range field accepts value “0 to 8191” in Modify Lo cation form

P-30456 Search filter error for boolean attribute

P-30467 Piping: choose should say which spec it is using

23965 P-30501 Diagrams: Enabled undefine button causes exception

23978 P-30527 Structures: Plines do not display on GENSECs

P-30529 Some Panel Clashing not showing up in 3D View and Clasher Graphics Window

23967 P-30541 Equipment: Primitive NXTR displaced when Apply button on Modify NXTR form is clicked.

P-30549 Sch. M M: Unhandled error appears while viewing the schematic diagram in the View Diagram window

23939 P-30550 When we create pipe spools in SP6, it does not work properly.

24078 P-30596 Diagrams: Unexpected exception

P-30612 Cable Design: User not able to copy the cableway elements upon entering the number of copies more then1

P-30636 Cable Design: (2,751) Variable Spec does not exist error occurs while creating Cable Material

23986 P-30637 Structures: Modifing NXTR in Panels & Plates application has inconsistent behaviour

23804 P-30652 Bolt Table utility form screen shots

P-30654 Unhandled err occurs while selecting valves in Editor Mode by drawing rectangle in 3Dview

24053 P-30655 PSI: Not Working, Output files not being produced

24128 P-30669 Diagrams: Startup error

24177 P-30691 Cats & Specs: Creating Branch Table functionality prompt C# exception error

P-30702 Admin: GPSETS need to be primary

21492 P-30771 Localization of OBST 0 and 1 primitive objects

P-30776 Performance of Instrument addin very slow if Inst DB contains large number of Tags

23065 P-30777 Piping: Angle selection does not work with spaces in STYPEs.

P-30783 MDS: Error “(2,752) Array element 1 does not exist” appears while creating a Vessel

P-30795 Improved Integration between PDMS 12.0.SP6 and other products

24383 P-30884 Piping: When we insert component, it does not work properly.

21493 P-30886 Nuclear Concrete Design: pseudo attribute displaying thickness

P-30957 Isodraft: Error "(61,143)Cannot access directory / - reset to local directory " is given

P-30962 MDS: Error message “F&M: Object or Value is unset” given when modifying support

P-30974 License expiring message appears every time bran is dropped

24489 P-30975 Modify Pipe – Change Detail Form Fails is the “System” is Deleted

24372 P-30981 DWG Export Error "External component has thrown an exception"

Page 12: d51925

Product Release Letter

d51925.doc 14-Jul-2010 Copyright 2010 AVEVA Solutions Limited Page 12 of 13

24520 P-30983 .NET error on Drawlist Primitives

P-30990 An error message is displayed while selecting Bend in Component Creation form.

P-30996 Sch. M M: Import of large data sets from Inst. needs filter

24531 P-31007 Global Daemon Signal 11 trapped if no transaction db

P-31017 Creation of DBJunk File when replicating and creating project (12.0.SP6)

24604 P-31068 Global: Location creation Allocation Count wrong

P-31075 Section 2.8 Save Result link in the Nuclear Concrete Quantities User Guide corrected

P-31110 New PML option to capture 3D view

24657 P-31139 Piping: Component Creation form Error after reducer

P-31160 Cats & Specs: Value is invalid err occurs while adding new items in Specification window

P-31161 SQL-Direct: ‘PDMSProv OLE DB Provider 12.0’ is not listed in the Data Link Properties dialog

P-31188 Sch. M M: Exception message when mapping file for Inst. data update is missing

P-31229 User Documentation Quality Improvements

P-31247 PDMS -Crash opening alpha log

24551 P-31251 Diagrams: Limitations on dwg export

P-30240 P-30321 P-30570 P-30640 P-30647

A number of improvements have been made to improve operation when PDMS is installed in a folder with a pathname including spaces; however, this is still not recommended and may require some amendments.

23482 P-30726 Isodraft fails with default option files if PDMS has space in path

23058 P-29815 Project Creation Wizard cannot create projects if there are spaces in install folder path

23094 P-29892 Global: Location Check fails if PDMSWK path has spaces

P-30300 PSI: Problems if installation folder contains spaces

P-30301 MDS: Problems if installation folder contains spaces

PRODUCT QUALITY STATEMENT

The development, maintenance and testing of AVEVA Solutions‟ software products is carried out in accordance with the company‟s KEYSTONE lifecycle processes and this document includes a summary of the testing carried out on this release and a list of significant defects known to exist at the time of release.

Development Testing

Developers have carried out unit testing of each enhancement and/or fix in the development environment to verify that any new functionalities have been correctly implemented and identified defects have been corrected. Regression tests have been run in the development environment to verify that enhancements and/or fixes have not adversely affected the integrity of the product.

System Testing

Independent system testing has been carried out on the product, as released, to verify that it installs correctly in all supported configurations and that product functionality operates as intended, subject to any known exceptions listed below.

Acceptance Testing

This document has been prepared before Acceptance Testing. This product release will be subjected to an acceptance test by AVEVA‟s Group Solutions Centre.

Page 13: d51925

Product Release Letter

d51925.doc 14-Jul-2010 Copyright 2010 AVEVA Solutions Limited Page 13 of 13

AVEVA‟s Group Solutions Centre is satisfied that the System Testing for this release is sufficient to assure product quality. Any exceptions found during Acceptance Testing or after release will be reported in the Product Release Latest Update Note on AVEVA's support web site http://downloads.aveva.com/51925/w51925.pdf.

Exceptions – Significant Defects and Recommended Workarounds

AVEVA has been advised by a customers of a problem with Symantec Endpoint Protection. It seems that it can cause networking problems on recent versions of Windows (including Vista and Windows 7) which can cause the computer to lose all network connections. This appears to happen in a PDMS environment after a few hours work! For details, please see http://service1.symantec.com/SUPPORT/ent-security.nsf/docid/2008081513390448. AVEVA intends to fix the defects listed below in a fix release or service pack as soon as reasonably possible. Incident number

Defect number

Description Recommended Workaround

SI-18428 MDS: Occasionally the Ancillary Selection form that is used to add ATTAs to Pipe, HVAC and Tray elements remains open when the „OK‟ button is clicked. If the user then closes the form by using the „Close‟ button, and then tries to re-open it, the application will effectively crash.

Allow the form to close of its own accord. This will occur when the main MDS Framework form closes.

P-31274 Cable Design: If a CWBRAN is claimed by a user, another user can still split the CWBRAN – the latter will have only the newly created element claimed and the elements are not split as would be expected.

It is not thought that this can cause a major issue but it will be corrected as soon as possible to ensure that the user wishing to perform the split is given an „Unable to Claim‟ error.

SI-25161 P-31491 In Windows 7 using Schematic Model Manager, if the user first imports and displays a diagram in the viewer,

then selects the Import Icon or File > Import> Diagrams

or File > Import> Diagram Set, an Unhandled

Exception is raised. Note this defect only occurs on

Windows 7.

This defect is caused by a conflict with the Diagram Viewer. Following an import and display of a

diagram, select Help >

Contents and then

close the Help dialogue. The Import function will then work correctly.

SI-25254 P-31606 PDMS executables cannot be started directly on Windows 7 but must be started from a .bat file. This is how PDMS is normally started from pdms.bat. This affects the integration between AVEVA Instrumentation and PDMS on Windows 7 as AVEVA Instrumentation fails to connect to PDMS.

This will be corrected in a future release.