Devise simplified equation to calculate the heat loss with exhaust gases in the boiler that burns heavy fuel oil Salah Salem Ali Efficiency And Test Senior Engineer Al-HISWA Thermal Power Station -Aden [email protected]
Transcript
Page 1: Develop a simple equation to calculate the heat loss due to flue gases in boiler

Devise simplified equation  to calculate the heat loss with exhaust gases in the

boiler that burns heavy fuel oilSalah Salem Ali

Efficiency And Test Senior Engineer Al-HISWA Thermal Power Station -Aden

[email protected]

Page 2: Develop a simple equation to calculate the heat loss due to flue gases in boiler

• This paper had come as a result of practical demand that is finding simple and quick equation, with enough accuracy to calculate the heat loss with exhaust gases (q2) in the boiler, and also count the efficiency (ηg) of the boiler , so that it to be facilitated the specialist researcher to find out (q2), and thus (ηg) immediately without going to the long equations.

Abstract

Page 3: Develop a simple equation to calculate the heat loss due to flue gases in boiler

INTRODUCTION •One of the popular equations to

calculate the heat loss with flue gasses q2 ( russian standard ) is:

Look how it is so long .

Page 4: Develop a simple equation to calculate the heat loss due to flue gases in boiler

•But by the developed simplifiedequation we can get the heat loss with flue gasses (q2) by this simple equation:

2

26fg fg cat t

q

Page 5: Develop a simple equation to calculate the heat loss due to flue gases in boiler

How was the access to this equation?

By indirect method to find the efficiency of :boilers

Page 6: Develop a simple equation to calculate the heat loss due to flue gases in boiler
Page 7: Develop a simple equation to calculate the heat loss due to flue gases in boiler

Multiply each end by :

Page 8: Develop a simple equation to calculate the heat loss due to flue gases in boiler
Page 9: Develop a simple equation to calculate the heat loss due to flue gases in boiler
Page 10: Develop a simple equation to calculate the heat loss due to flue gases in boiler
Page 11: Develop a simple equation to calculate the heat loss due to flue gases in boiler
Page 12: Develop a simple equation to calculate the heat loss due to flue gases in boiler

Putting these values in the previous equation we get the final version of the simplified equation to find the percentage of boiler heat loss with exhaust

gases :

Page 13: Develop a simple equation to calculate the heat loss due to flue gases in boiler

• This extracted equation had been tested and compared its results with the reference test after installation the boiler of AL-HISWA POWER STATION-Aden by the manufacturing authority by hand account method, and also with the tests after the over haul maintenance which had been done by computer application. The comparison results were excellent, so that the error rate in finding out q2 is( -1.91 % max only one time, and maximum error rate of finding out (ηg) is (-0.1%), and sometimes the error for q2 & ηg was zero .

Page 14: Develop a simple equation to calculate the heat loss due to flue gases in boiler

Comparison with the results of reference tests of boiler no.1 Al-Hiswa thermal station – Aden 1986

Page 15: Develop a simple equation to calculate the heat loss due to flue gases in boiler

Comparison with the results of reference tests of boiler no. 2 - Al_Hiswa thermal station-1987

Page 16: Develop a simple equation to calculate the heat loss due to flue gases in boiler

maintenance Comparison with the results of after overall test of boiler no. 3 Al_Hiswa thermal station

2005

Page 17: Develop a simple equation to calculate the heat loss due to flue gases in boiler

No

Data The results

q2 ˬ % ηg ˬ %

Da, t/h tf.g. c0 tc.aˬ C

0 αfg q5ˬ % Test result

By equation

error rate %ˬ

Test result

By equation

error rate %ˬ

Comparison with the results of reference tests of boiler no. 1 - Al_hiswa thermal station - Aden 1986

1 157.4 145 40 1.3 0.64 5.25 5.25 0.0 94.11 94.11 0.0

2 140 145 45 1.384 0.72 5.3 5.32 0.38 93.98 93.96 -0.02

3 123.3 144 40 1.372 0.82 5.42 5.49 1.29 93.76 93.69 -0.07

4 98 135 43 1.44 1.03 5.07 5.10 0.59 93.9 93.87 -0.03

5 96.1 131.5 36.2 1.411 1.05 5.1 5.17 1.37 93.85 93.78 -0.07

6 93.1 132.3 36 1.34 1.08 4.93 4.96 0.61 93.99 93.96 -0.03

7 88.6 137 37.4 1.376 1.14 5.24 5.29 0. 95 93.62 93.57 -0.05

Comparison with the results of reference tests of boiler no. 2 - Al_hiswa thermal station – 1987

1 156.2 142 40 1.195 0.65 4.75 4.69 -1.26 94.6 94.66 0.06

2 156.3 141.5 40 1.208 0.65 4.77 4.72 -1.05 94.58 94.63 0.05

3 139.2 143 40 1.235 0.73 4.93 4.89 -0.81 94.34 94.38 0.04

4 119.7 139 40 1.222 0.84 4.7 4.65 -1.06 94.46 94.51 0.05

5 117.8 139.5 40 1.271 0.86 4.87 4.86 -0.21 94.27 94.28 0.01

6 100.3 140 34 1.359 1.0 5.46 5.54 1.47 93.54 93.46 -0.08

7 78 137 45 1.396 1.3 4.94 4.94 0.0 93.76 93.76 0.0

8 75.6 130 38 1.457 1.33 5.07 5.16 1.78 93.6 93.51 -0.09

Comparison with the results of after overall maintenance test boiler no. 3- Al_hiswa thermal station 2005

1 160.1 144 39 1.4 0.65 5.76 5.65 -1.91 93.59 93.7 0.1

2 160 145 36 1.52 0.65 6.43 6.37 -0.93 92.92 92.98 0.06

3 140.1 146 36 1.50 0.74 6.42 6.35 -1.09 92.84 92.91 0.08

4 140 148 36 1.51 0.75 6.57 6.50 -1.07 92.68 92.75 0.08

5 120.1 149 36 1.53 0.87 6.7 6.65 -0.75 92.43 92.48 0.05

6 120 150 36 1.55 0.87 6.84 6.8 -0.58 92.3 92.34 0.04

7 100.1 152 37 1.74 1.04 7.67 7.7 0.39 91.29 91.26 -0.02

8 100 152 37 1.79 1.04 7.86 7.92 0.76 91.1 91.04 -0.06


Recommended