DES FE Workshop at FNAL December 14-15, 2005Vaidas Simaitis, University of Illinois at Urbana-Champaign
1
DHE Crate Design and Status
• The mechanical design is ~95% completed.• ~5% = finalize mounting to telescope.• For the prototype, we are ignoring telescope
requirements for cooling water, temperature monitoring, and other instrumentation.
• Most prototype manufactured parts are out for quote.
• Most prototype purchased parts are on hand.
DES FE Workshop at FNAL December 14-15, 2005Vaidas Simaitis, University of Illinois at Urbana-Champaign
2
6-SLOT + 4-SLOT Crate
Schroff Card Guides and Rails are on hand. 4-slot backplane is on hand, 6-slot on order
Chassis plate designs finished, drawings out for quote.
DES FE Workshop at FNAL December 14-15, 2005Vaidas Simaitis, University of Illinois at Urbana-Champaign
3
HEAT EXCHANGERS & FANS
2 Fan Manifold and 2 Cooling Manifold drawings out for quote
2 fans on hand from early Monsoon design
1 heat exchanger on hand, 1 on back order
DES FE Workshop at FNAL December 14-15, 2005Vaidas Simaitis, University of Illinois at Urbana-Champaign
4
MAIN MANIFOLDS
2 Main manifold drawings out for quote
Heat sink extrusion just arrived.
2 Thermo-electric coolers (TEC) not yet ordered.
DES FE Workshop at FNAL December 14-15, 2005Vaidas Simaitis, University of Illinois at Urbana-Champaign
5
POWER SUPPLIES
2 Power Supply Mount drawings out for quote
2 Power Supplies to be ordered by Todd
DES FE Workshop at FNAL December 14-15, 2005Vaidas Simaitis, University of Illinois at Urbana-Champaign
6
POWER SUPPLY MANIFOLDS
2 power supply manifold drawings out for quote
2 delrin crate mounting bars on hold until mounting design is done (not shown)
DES FE Workshop at FNAL December 14-15, 2005Vaidas Simaitis, University of Illinois at Urbana-Champaign
7
PROTOTYPE ASSEMBLY
• Expect to receive chassis and manifolds by the end of January
• Assemble prototype, without heat shields• If assembly is OK, order heat shields• Order TEC’s, and TEC mounts• Test air flow and heating and cooling
through February• Install TEC’s and heat shields
DES FE Workshop at FNAL December 14-15, 2005Vaidas Simaitis, University of Illinois at Urbana-Champaign
8
THERMOELECTRIC MOUNT
DELRIN INSULATOR / SPACER
TEC
HEAT SHIELD WILL ATTACH TO COPPER PLATE
DES FE Workshop at FNAL December 14-15, 2005Vaidas Simaitis, University of Illinois at Urbana-Champaign
9
View with HEAT SHIELDS
DES FE Workshop at FNAL December 14-15, 2005Vaidas Simaitis, University of Illinois at Urbana-Champaign
10
CRATE Installed on Cylinder
DES FE Workshop at FNAL December 14-15, 2005Vaidas Simaitis, University of Illinois at Urbana-Champaign
11
MOUNTING PIVOTS
NORMAL LOCKED POSITION
EXTENDED POSITION
PIVOT
LOCK
DES FE Workshop at FNAL December 14-15, 2005Vaidas Simaitis, University of Illinois at Urbana-Champaign
12
Why PIVOTS ?
• Allow some FLEXIBILITY to avoid possible obstructions, for extraction or insertion of front modules or transition cards.
• PIVOTS allow either end to be angled out, and are locked in position for SAFE access.
• Little extra $$ for a lot of SAFETY!
• Final design is on hold until mounting method and position is OK’ed by FNAL
DES FE Workshop at FNAL December 14-15, 2005Vaidas Simaitis, University of Illinois at Urbana-Champaign
13
Z-AXIS VIEW WITH R=52” ID
DES FE Workshop at FNAL December 14-15, 2005Vaidas Simaitis, University of Illinois at Urbana-Champaign
14
WORST-CASE MODULE ACCESS
DES FE Workshop at FNAL December 14-15, 2005Vaidas Simaitis, University of Illinois at Urbana-Champaign
15
CRATE PIVOTED FOR ACCESS
DES FE Workshop at FNAL December 14-15, 2005Vaidas Simaitis, University of Illinois at Urbana-Champaign
16
DESIGN DETAILS
• Our design resides in much detail at our UIUC website at CLICK HERE or copy and paste:
• web.hep.uiuc.edu/Engin/DES/DHE_10_Crate/DHE_10_Crate.html
• The best way to see the design is to download the free DWF Viewer.
• You can then rotate, zoom in/out, hide parts in assemblies so you can see the insides, and print any view you like.
• Else, you’re stuck with the 2D PDF views.