33
DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012
Transcript
Page 1: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

DigitalDiagnostLong length imaging &Automatic Image Stitching

Diagnostic X-ray, Marketing

January 2012

Page 2: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

2

Content

1. DigitalDiagnost benefits

2. Philips’ single focus approach

3. Show me howa. Full legs, 3 images with movable vertical stand

b. Full legs, 3 images with fixed vertical stand

c. Full spine, 2 images on table

4. Flexibility: vertical stand and table

5. The Eleva concept advantage

6. Reduced dose

7. Latest literature on dose reduction

8. Dedicated accessories

9. Flex room with swiveling table

10. Stitching and PCR integration

Page 3: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

3

DigitalDiagnost benefitsfor long length imaging

• Available with all vertical stands and tables

• “Single focus” approach to minimize distortions

• Easy to perform- Adjust collimation, the system determines how many

images are necessary to acquire

• Low dose

• Fully automatic process- Images acquisition with motorized tube and detector

movements- Creation of the resulting composite image

o Manual correction possible

• No extra workstation- Everything done by the Eleva workspot- Includes dedicated orthopedic measurements

Page 4: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

4

Automatic image stitchingPhilips’ single focus approach

Parallax error

Single focus

• More accurate overlaps areas• Minimizes stitching distortions

Multiple focus

• Big distortions in overlap areas

Page 5: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

5

Stitching with moveable vertical stand (VM)

Page 6: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

6

Single focus

Tube will rotate around its focal spot

Automatic image stitchingShow me how: acquisition principle

Movable vertical stand

Detector will move vertically from top to

bottom and stop to acquire 2 or 3 images

Page 7: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

7

Automatic image stitchingShow me how: a 3 steps procedure

Movable vertical stand

Position patient standing in front of the detector(patient stand recommended)

1

Adjust collimation light to get the required patient coverageThe system will automatically determine how many images need to be acquired.

2

3 Press exposure switch

Page 8: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

8

Automatic image stitchingShow me how: fully automatic acquisition

Movable vertical stand

Page 9: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

9

Automatic image stitchingShow me how: fully automatic acquisition

Movable vertical stand

Page 10: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

10

Automatic image stitchingShow me how: fully automatic acquisition

Movable vertical stand

Page 11: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

11

Automated detection of overlaps

Using ruler and anatomy Motion compensation No visible borders Equalizing contrast & brightness

Automatic image stitchingShow me how (3 images, full legs)

Page 12: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

12

Stitching with fixed vertical stand (VS)

Page 13: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

13

Single focus

Tube will rotate around its focal spot

Detector will move vertically from top to bottom and stop to acquire 2 or 3 images

Automatic image stitchingShow me how: acquisition principle

Fixed vertical stand

Page 14: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

14

Automatic image stitchingShow me how: a 3 steps procedure

Position patient standing in front of the detector(patient stand recommended)

1

Adjust collimation light to get the required patient coverage

The system will automatically determine how many images need to be acquired.

2

3 Press exposureswitch

Fixed vertical stand

Page 15: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

15Fixed vertical stand

Automatic image stitchingShow me how: fully automatic acquisition

Page 16: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

16Fixed vertical stand

Automatic image stitchingShow me how: fully automatic acquisition

Page 17: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

17Fixed vertical stand

Automatic image stitchingShow me how: fully automatic acquisition

Page 18: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

18

Automated detection of overlaps

Using ruler and anatomy Motion compensation No visible borders Equalizing contrast & brightness

Automatic image stitchingShow me how (3 images, full legs)

Page 19: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

19

Stitching with side suspended table (TH-S)

(stitching on table is also possible with the traditional, central base, TH table)

Page 20: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

20

Single focus

Tube will rotate around its focal spot

Automatic image stitchingShow me how: acquisition principle

TH-S table

Detector will move horizontally from right to left and stop to acquire 2 images

Page 21: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

21

Automatic image stitchingShow me how: a 3 steps procedure

TH-S table

Position patient laying on the table

1

Adjust collimation light to get the required patient coverage

The system will automatically determine how many images need to be acquired.

2

3

Press exposure

switch

Page 22: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

22

Automatic image stitchingShow me how: fully automatic acquisition

TH-S table

Page 23: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

23

Automatic image stitchingShow me how: fully automatic acquisition

TH-S table

Page 24: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

24

Automatic image stitchingShow me how (2 images, full spine)

Automated detection of overlaps

Using ruler and anatomy Motion compensation No visible borders Equalizing contrast & brightness

Page 25: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

25

• Available with all vertical stands and tables- Demonstration video: long length exams performed in a Flex room, vertically and on table

• Key numbers

Place Max patient coverage

Max number of acquired images

Minimum SID required

Vertical stands 120 cm (47”) 3 260 cm (102”)

Tables 80 cm (31”) 2 160 cm (63”)

Automatic image stitchingFlexibility: at the vertical stand and at the table

Page 26: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

26

Automatic image stitchingThe Eleva concept advantage

• Thanks to Eleva, long length imaging is seamlessly integrated in you workflow

– Fully automatic motorized acquisition procedure– Fully automatic stitching algorithm

• Manual override possible

– UNIQUE image processing– No extra workstation

• Saves space and time

– Dedicated orthopedic measurements• Cobb’s angles, femoral height difference, segments,

angles, measurements calibration

• Fast & efficient procedure– Customized exposure & image processing presets– Performed with very few clicks (touches)

Page 27: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

27

Automatic image stitchingThe Eleva concept advantage

Page 28: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

DigitalDiagnostStandard CR

28

Automatic image stitchingTypically half the radiation dose

~ 32 µGy.m² ~ 12 µGy.m²

~ 4 µGy.m²

~ 16 µGy.m²

(typical Dose-Area-Product (DAP) values. Values may vary with patient and examination conditions)

Page 29: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

29

Automatic image stitchingLatest literature on low radiation dose & pediatrics with DigitalDiagnost

A big improvement in Digital Radiography

Philips DigitalDiagnost minimizes X-ray doses at Val d’Hebron Maternity/ Children’s Hospital, Barcelona, Spain.

(Customer testimonial, October 2010)

Link to document

Low-Dose Full-Spine Radiography with Digital Flat Panel Detector and Image Stitching System

When imaging scoliosis patients, a flat-panel detector combined with an image stitching system can substantially reduce the exposure dose.

(Study made on DigitalDiagnost, Germany, November 2011)

Link to document

Page 30: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

Extra ruler for table

• Patient stand- More comfort and confidence

throughout the procedure

• Spine stitching filters- Minimize ghosting artifacts

with challenging patients

• Extra lead ruler, straps

• Comes with dedicated guide

Link to document

Automatic image stitchingDedicated accessories

Set of 2 spinefilters

Patient stand

Page 31: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

31

Automatic image stitchingFlex room swiveling table and stitching

• In small rooms, a swiveling table can be a great complement to stitching

• Table is swiveled during stitching procedure

• Gives more space and avoids the tabletop being in X-ray beam

• Improves

Access to the patientAccess to the system Image quality

Page 32: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

32

Automatic image stitching with PCREven more long length imaging flexibility with PCR integration

• With PCR integration & stitching together, automatic stitching is also possible on DigitalDiagnost with PCR “long view” cassettes

- 2 or 3 imaging plates per cassette- Plates images are automatically stitched together after cassette reading- Several cassette sizes available to fit dedicated needs

• Same stitching algorithm & UNIQUE image processing- Comparable image impression with DR

• Quicker acquisition procedure than DR stitching- Only 1 exposure shot

• Alternative to DR stitching for some particular situations- Agitated patients- Patients who cannot stand for more than a few seconds- Trauma

Example: a 24 x 57 cm or 10 x 23” cassette allows to X-ray a broken

femur with both knee & hip joins or a child spine

Long viewcassette size

# of platesin cassette

35 x 124 cm (14 x 49”) 3

35 x 102 cm (14 x 40”) 3

35 x 84 cm (14 x 33”) 2

24 x 57 cm 2

10 x 23” 2

Page 33: DigitalDiagnost Long length imaging & Automatic Image Stitching Diagnostic X-ray, Marketing January 2012.

33


Recommended