  • 7/28/2019 direct drive.pdf

    1/12

    Baldor Adjustable SpeedDirect Drive Cooling Tower

    Motor and Drive System

  • 7/28/2019 direct drive.pdf

    2/12www.baldor.com1

    Adjustable Speed Direct Drive

    Cooling Tower System

    New Direct Drive Technology Improves

    Reliability, Reduces Maintenance, Runs

    Quieter & Saves EnergyBycombiningthetechnologiesofthefieldprovenandpowerdenseAClaminated

    frameRPMACmotorwithhighperformancepermanentmagnet(PM)salientpole

    rotordesignsandthematchedperformanceofanadjustablespeeddrive,Baldor

    Electriccanofferhightorquedirectdrivemotorsforcoolingtowerapplications

    withallthebenefitsofvariablespeedcontrolandeliminatingthecostand

    maintenancerequiredfortraditionalgearboxorbeltedsolutions.Thefancouples

    directlytothemotorandiscontrolledbyauniqueACdrivetoprovideoptimal

    speedandcoolingtowerperformancethatrunsquieterwithreducedenergy

    consumption.ThedriveisdesignedtoaccommodatethemostcommonHVAC

    communicationprotocols.

    Direct Drive RPM AC SynchronousPM Motor Reduces Maintenance Cost

    TheRPMACsynchronousPMmotoruseslaminatedfinnedframeconstructiontoprovideahighlyefficient

    powerdensepackagewithflangemountingdimensionsthatcanreplacetherightanglegearboxandjackshaft

    installationinmanyconventionalcoolingtowers.Thissametechnologyisofferedinconventional,yetpower

    dense,footmounteddesignsthatcanreplacethebeltandsheaveapplicationwheremoreverticalmounting

    spaceisavailable.Derivedfromoneofthetoughestmotorplatformsusedinthemostdemandingindustrial

    applications,theRPMACmotoristherightsolutionforoperationinsidethetowershotandhumidenvironment.

    TheTEAO(totallyenclosedairover)RPMACcoolingtowermotorisdesignedforminimalmaintenance.Bearings

    requirelubricationonlyonceperyear.WateringressalongtheshaftispreventedwiththeuseofanInpro/

    Sealbearingisolatorandaslinger.TheelectricalinsulationsystemismanufacturedusingaVPI(vacuum

    pressureimpregnation)processthatensureslongmotorlifeeveninthemostextremeenvironmentalconditions.

    Condensationdrainsrelieveanymoisturethatmaycollectinsidethemotor.Nomorechanginggearoil,lubricatingpillowblockbearingsorchangingoutbelts.

    Baldor VS1CTD PM Cooling Tower Drive

    TheBaldorVS1CTDintegratescustomfeaturesthathavebeendesignedexclusivelyforthecoolingtower

    industry.TheVS1CTDutilizesourMatchedPerformancephilosophytopaireachRPMACPMmotorwitha

    specificcontrol.CriticalmotoroperationalparametersareintegratedrightintotheVS1CTDfirmwaretoprovide

    simplifiedCoolingTowerstartups,eliminatingtheneedforuserstoentercomplexinformationintothecontrolor

    theneedtotunethecontroltothemotorpriortooperation.SincetheVS1CTDistargetedforuseinthecooling

    towermarket,muchofthecomplexitythattypicallyresidesingeneralpurposecontrolshasbeeneliminated

    furtheraddingtothesimplicityofourAdjustableSpeedDirectDriveCoolingTowerMotorandDriveSystem.

    Whensystemautomationandcontrolisarequirementforyourcoolingtoweroperation,theBaldordrivereadilycommunicateswithmultiplecommunicationnetworksincludingMODBUS-RTU,MODBUS/TCP,LonWorks,Metasys-N2,BACnet,EtherNet/IP,DeviceNetandPROFIBUS.

    Field Tested Reliability

    AfterextensiveLabtestingatBaldorsfacility,motoranddrivesystemshavebeeninstalledandfieldtestedforaslongasthreeyears.Onesystem

    isrunningunderacontrolledenvironmentononeoftwoidenticalcoolingtowersatClemsonUniversity.Bothtowerswereinstrumentedandthe

    traditionalgearedsystemwascomparedtotheoneconvertedtouseBaldorsAdjustableSpeedDirectDriveMotorandDriveSystem.Eachtower

    hadthesame5blade18footdiameterfan.Theconversionwasmadeinlessthanaday.Performanceresults,whichwereverifiedbyathird

    party,measuredaninputkWpowersavingsof11.8%comparedtoatraditionalgearedsystem,withhighspeednoisereductionfrom82.3dBAto

    74.4dBAandreducedvibration.

  • 7/28/2019 direct drive.pdf

    3/12www.baldor.com

    RPM AC Direct Drive Cooling Tower Features & Benefts

    Direct Drive Motor

    Eliminatestheneedforagearbox,jackshaft,pillowblockbearingsandcouplings

    Reducesmaintenanceandprovidesimprovedreliability

    Eliminatescoolingwatercontaminationbyeliminatinggearboxoilandleakage

    Reducespowerconsumption

    Resultsinincreasedsafetybecausetherearefewermechanicalcomponents

    Water-tightmotordesignoperatesintheairstream

    Eliminatesthealignmentofmechanicalcomponentsforquickerinstallationandreducedinstallationcosts

    Bearings and Seals

    OversizedtomaintainlongerbearinglifeexceedingL-10100,000hours

    Greaselubricatedforlonglife

    Handlesfanloadswithimprovedreliability

    ProvenInpro/Sealbearingisolatorwithslingerumbrellaoverseal

    Onlyoneingresspoint

    InsulatedoppositedriveendbearingonFL440andFL5800

    Adjustable Speed Control

    DesignedspecificallyfortheCoolingTowerIndustryandcanbesetattheoptimumspeedpoint SensorlessPermanentMagnetmotorcontroloperateswithoutanencoderorresolver

    Trickleheatingeliminatesneedformotorspaceheaters

    NotuningisrequiredduetotheMatchedPerformanceofthemotorandcontrol

    Allowsforasoftstart(controlledramp)

    Savesenergyandreducesmechanicalstressonthesystem

    Improvessystemreliabilityandextendslife

    Reducesnoise

    Allowsforoptimizedreturnwatercoolingtemperatureforoptimizedcompressoroperation

    Tricklecurrentforbrakingpreventsfanwindmillingwhennotinoperation

    Systemresonancespeedscanbebypassed

    Communication Protocols

    UtilizesMODBUS-RTU,MODBUS/TCP,EtherNet/IP,LonWorks,Metasys-N2,BACnet,DeviceNetorPROFIBUSprotocols Interfaceswithexistingbuildingautomationsystems

    MATCHED

    P

    ERFORMA N

    C E

    Retroit or New Tower Designs

    RPMACcoolingtowermotorsareavailableineitherflangemountorfootmount

    designsformountingintheairstream.Theflangemountunitsaredesignedtobe

    interchangeablewithmanypopulargearboxboltholemountingconfigurations.Shaft

    height,diameterandflangemountingdimensionscanbedirectlyinterchangeable

    withsomeexistingcoolingtowergearboxdesigns.Highermotortorqueratingsare

    availableusingtallermotorswhenspaceisavailable.Inaddition,traditionalfootmount

    constructionisavailable.Bothflangeandfootmountdesignsareavailableinawide

    torquerangeinframesizesFL250,FL280,FL440andFL5800.

    A typical conventional fan drive

    arrangement of a gearbox mounted

    under the fan.

    Baldors Direct Drive motor eliminates many components of a right angle

    geared system.

    Conventional Tower Design New Direct Drive Tower Design

  • 7/28/2019 direct drive.pdf

    4/12www.baldor.com3

    RPM AC Cooling Tower Motor and Drive Specifcations

    Motor

    MotorFrame Size

    Max. Torque(lb. ft.)

    Min. Re-quired AirVelocity(ft/min)

    Aprox.Wgt. (lb)

    *Est. MotorHeight

    M (in.)

    CatalogNumber

    FL2554 90

    500

    375 15 Custom

    FL2562 155 440 17 CustomFL2570 215 515 19 Custom

    FL2578 290 590 21 Custom

    FL2873 305

    750

    610 19 Custom

    FL2882 415 705 21 Custom

    FL2890 510 790 23 Custom

    FL2898 590 860 25 Custom

    FL4472 500

    750

    1154 18 Custom

    FL4477 720 1290 19 Custom

    FL4485 1050 1515 21 Custom

    FL4493 1375 1730 23 Custom

    FL4402 1820 1980 25 Custom

    FL4413 1275 2290 28 Custom

    FL4421 2740 2510 30 Custom

    FL4429 3050 2730 32 Custom

    FL4440 3520 3035 35 Custom

    FL5816 4744

    750

    5445 37 Custom

    FL5818 5400 5880 39 Custom

    FL5820 6058 6315 41 Custom

    FL5822 6715 6750 43 Custom

    FL5824 7372 7185 45 Custom

    FL5826 8029 7620 47 Custom

    FL5828 8686 8055 49 Custom

    FL5830 9343 8490 51 Custom

    FL5832 10000 8925 53 Custom

    Selectmotorframesizeasdeterminedbyrequiredfantorque.

    FanTorque=(HP*5252)/FanSpeed.

    UseexistingmotorHPandfanspeedtocalculaterequiredtorque.

    Drive

    Max. Amps HP FrameCatalogNumber

    240 Vac

    19.4 5 AA VS1CTD25-1B

    19.4 7.5 AA VS1CTD27-1B

    37.0 10 B VS1CTD210-1B

    47.5 15 B VS1CTD215-1B

    59.8 20 B VS1CTD220-1B

    70.4 25 C VS1CTD225-1B

    91.5 30 C VS1CTD230-1B

    91.5 40 C VS1CTD240-1B

    147.5 50 D VS1CTD250-1B

    147.5 60 D VS1CTD260-1B

    480Vac

    11.9 10 AA VS1CTD410-1B

    23.0 15 B VS1CTD415-1B

    28.9 20 B VS1CTD420-1B

    34.0 25 B VS1CTD425-1B

    44.2 30 C VS1CTD430-1B

    55.3 40 C VS1CTD440-1B

    65.5 50 C VS1CTD450-1B

    90.8 60 D VS1CTD460-1B

    116.6 75 D VS1CTD475-1B

    136.3 100 D VS1CTD4100-1B

    143.8 125 D VS1CTD4125-1B

    204.0 150 E VS1CTD4150-1T

    256.7 200 E VS1CTD4200-1T

    600Vac

    9.4 10 AA VS1CTD510-1B18.7 15 B VS1CTD515-1B

    23.0 20 B VS1CTD520-1B

    27.2 25 B VS1CTD525-1B

    33.6 30 C VS1CTD530-1B

    42.6 40 C VS1CTD540-1B

    50.8 50 C VS1CTD550-1B

    72.8 60 D VS1CTD560-1B

    93.1 75 D VS1CTD575-1B

    117.5 100 D VS1CTD5100-1B

    132.8 125 D VS1CTD5125-1B

    173.6 150 E VS1CTD5150-1T

    218.8 200 E VS1CTD5200-1T

    Selectdrivebaseduponmotorfullloadamps.

    ForlineandloadreactorsseetheBaldor501catalog.

  • 7/28/2019 direct drive.pdf

    5/12www.baldor.com

    RPM AC Cooling Tower Motor DimensionsSelectmotorframesizebaseduponrequiredfantorque

    Min.

    Max.

    4 holes on

    X B.C.

    4 holes on

    Y B.C.

    Shaft

    Length

    UsableShaft

    Length

    Length

    M

    U

    Diam.

    FL Family

    MotorFrame Size

    * TypicalShaft Length

    Usable ShaftLength

    * TypicalShaft Dia. U

    X Min.Bolt Circle (in.)

    Y Max.Bolt Circle (in.)

    Number ofholes per bolt

    circle

    FL25XX 8.5 6.94 1.999 14 16 4

    FL28XX 8.0,8.5 5.75,6.25 2.374 15-16Slot 20 4

    FL44XX 8.5,9.0,9.5 6.38,6.88,7.38 2.999 22 25 4

    FL58XX 12.0 6.88,11.75 4.999 34 8

    *Shaftlengthanddiametercanvarybyapplicationrequirements.Taperedshaftsarealsoavailable.Typicaltaperis1/2perfoot.Specialnon-standardshaftrequirementsmustbedenedontheorder.

    Motor Features

    Mountingpadforvibrationsensor

    Thermostatsoneperphasenormallyclosed

    Heavybuildexternalcoatings

    ProvenInpro/Sealbearingisolatorwithslingerumbrellaoverseal

    Proveninsulationsystemtechnologyusedinoff-shore

    drillingapplications

  • 7/28/2019 direct drive.pdf

    6/12www.baldor.com5

    Adjustable Speed Drive Cooling Tower DimensionsSelectdriveratingandframesizebaseduponmotorfullloadamps

    0.25(6.35)dia.

    Exhaust

    0.25(6.35) dia.

    B1

    A1

    A

    B1

    A1

    A

    0.35 (8.9)

    B C

    0.35(8.9) Exhaust

    B C

    # HolesSize

    AA 4 0.870 (22)

    Diameterinches (mm)

    # HolesDiameter

    inches (mm)Size

    B

    C

    D

    3

    333

    3211

    1.115 (28.3)

    1.362 (34.6)

    1.680 (42)

    2.470 (62.7)1.362 (34.60.500 (12.7)

    E

    1.115 (28.3)

    1.115 (28.3)

    1.115 (28.3)4.000 (102)1.680 (43)0.500 (12.7)

    3211

    Size AA

    FrameSize

    Dimensions inches (mm)Weightlb (kg)

    Outside Mounting

    Height (A) Width (B) Depth (C) Height (A1) Width (B)

    AA 12.27(311) 7.97(202) 8.21(208) 11.75(298) 7.38(187) 20(9.1)

    B 18(457) 9.10(231) 9.75(248) 17.25(438) 7.00(178) 30(13.6)

    C 22(559) 9.10(231) 9.75(248) 21.25(540) 7.00(178) 60(27.2)

    D 28(711) 11.50(292) 13.00(330) 27.25(692) 9.50(241) 120(54.4)

    E 42.81(1087) 18.75(476) 16.06(407) 39.75(1010) 15.75(400) 250(113.4)

    CustomenclosuresincludingNEMA4Xareavilable

  • 7/28/2019 direct drive.pdf

    7/12www.baldor.com

    Easy Field Installation

    Belowisamotorfanassemblybeingloweredintoposition.

  • 7/28/2019 direct drive.pdf

    8/12www.baldor.com7

    Baldor Cooling Tower Motor RFQ

    Company Name: Project:

    Fan Diameter (ft.) ____________________________ Air Flow (cfm) ___________________________

    Fan Speed (RPM) ____________________________ Ambient Temp. __________________________

    Existing Motor Hp____________________________ Static Pressure (inches of H20) _______________

    Fan Shaft Hp ____________________________ ___ Air Density (lb/ft3) ________________________(This is normally an odd number ex: 42.3 Hp based on operating conditions)

    Voltage Required ____________________________ Fan mfq P/N ____________________________

    Height Restrictions_________YES / NO ___________ No. Fan Blades __________________________

    A inches _________________________________If Yes, please give maximum height from motor to mounting plate to shaft extension (see diagram - A dimension)

    Match Existing Bolt Hole Pattern?____YES / NO _____

    If Yes, please give existing Bolt Hole Pattern ________________________________________________

    Air Velocity in Region of Motor (ft/min) _____________________________________________________

    (shaded area shown below)

    If retrot

    Gearbox Manufacturer_______________________________

    Gearbox Model No.__________________________________

    The Baldor Solution requires a Baldor CTPM VFD

    Approximate distance from motor to VFD location _______ Feet

    Drive location: Control Room __________ Outside: __________

    Fan Shaft Diameter (in.) Keyway (in.)

    1.999 .0005 1/2 x 1/4

    2.374 .0005 5/8 x 5/16

    2.624 .0005 5/8 x 5/162.999 .0005 3/4 x 3/8

    Other Shaft Dia. Requirements

    Required information to quote properly

    Questions regarding above information

    Please contact your local Baldor District Ofce

    6from

    Motor/Gearbox

    AirFlow A Small end dia B _________________________Large end dia C _________________________

    Length of taper L1 _______________________

    Length of exposed shaft L2_________________

    Keyway size F __________________________

    Shaft end drilled & tapped hole D ____________

    B

    C

    D

    L1

    L

    F

  • 7/28/2019 direct drive.pdf

    9/12www.baldor.com

    98

    97

    96

    95

    94

    93

    92

    Energy Efcient Premium Efciency PM

    %E

    FFICIENCY

    0 20 40 60 80 100 120

    % LOAD

    AnotherimportantaspectofthePMmotordesignversusatraditionalinductionmotorisitsabilitytomaintainhighefficiencyperformancewhen

    operatingunderlowloadconditionswhicharetypicalforvariablespeedfanapplications.

    V*S Control Provides Optimized Cooling Tower Perormance and

    Energy Savings Even Under Low Load Conditions

    Byoptimizingmotorspeedconsiderableenergycanbesaved.TheentirecoolingtowersystemmustbedesignedfortheWorstCase(orhighest

    airflow)scenario.Foroptimumsystemperformancethefanmayneedtooperateatreducedspeed.

    Asthespeedofthemotorisdecreased,theairflowdropsinacorrespondinglinearfashion.So,forexample,ifthemotorrunsatonly50%speed,

    theairflowiscorrespondinglyreducedto50%ofmaximumairflow.

    However,theinputpowertothemotorvarieswiththecubeofthemotorspeed.Forexample,ifamotorisrunathalf-speed,thepowerconsumed

    bythemotoris12.5%or1/8[i.e.()3]ofthepowerconsumedatfullspeed.So,iftheneededairflowcanbeachievedbyrunningathalf-speed,

    itispossibletosavealargeamountofenergy(seeenergychartbelow).

    Adjustable Speed Saves Energy

    Permanent Magnet Maintain Efficiency Over Wide Load Range

    0 20 40 60 80 100

    100

    80

    60

    40

    20

    0

    % RPM

    %I

    nputPower

  • 7/28/2019 direct drive.pdf

    10/12www.baldor.com9

    Why Baldor?

    Fornearly100years,Baldorhasstrivedtoprovide

    customerswiththebestvalueandreliabilityinindustrial

    electricmotors.Thatdedicationshowsincustomer

    preferenceforBaldorReliancemotors.Tobeconsideredas

    themostpreferred...

    Baldor offers the industrys broadest line of stock

    products.SavevaluabletimewithjustonecalltoBaldor.Weoffermorethan10,000stockmotors,drives,gearboxes,

    bearingsandPTcomponents.

    Energy-efficiency leader.Baldorbeganloweringtheenergyconsumptionofourmotorsinthe1920s,longbeforeothers

    wereeventalkingaboutit.Today,BaldorsexpansivelineofPremiumEfficiencymotorsextendsfrom1through15,000Hp.

    Baldorsmotorsoffercustomersthehighestoverallefficiency

    levelsintheindustry,includingBaldorRelianceSuper-E

    (1through500Hp)motorsthatexceedNEMAPremium

    efficiencies.

    Baldorcontinuallylooksforapplicationswhereimprovements

    inenergyefficiencyispossible.Byreplacingconventional

    coolingtowerfandrivesystemswithBaldorsadjustablespeed

    directdrivemotoranddrivesystem,significantimprovements

    inenergyefficiencyarepossible.

    Baldor products are

    available at more locations

    than any other brand.

    Our35districtoffices

    acrossNorthAmericaand

    officesaroundtheworld,

    offerimmediateandlocal

    availabilityofBaldorproductstothousandsofcustomers.

    Continuous innovation to improve reliability.

    Baldorleadsthemotorindustryinapplyingnewtechnologies

    toimprovemotorreliability.Recentimprovementstotheline

    ofSevereDutymotorsarefurtherproofthatBaldoristhe

    leaderinmotorsforprocessindustryapplications.These

    improvementsareexplainedindetailinthefollowingpages.

    Industrys shortest

    lead times/Flexible

    manufacturing.Baldorhasthe

    industrysshortest

    leadtimesoncustom

    motors.Ourunique

    LEANFLEXFLOW

    manufacturing

    processletsus

    produceanyorderin

    anyquantity,quicklyandefficiently.

    Industrys best information.OnlyBaldorofferscustomers

    somanychoicesforproductinformationwithawidevarietyof

    catalogsandproductbrochures,theBaldorWebsiteatwww.

    baldor.com,oryoumaytalktoaBaldorcustomerservice

    personatoneofoursalesoffices.

    94%2003

    20%1985

    50%1990

    90%2000

    95.5%2007

    Customer Preference

    The percentages shown reflect results of studies conducted

    in which Baldor was chosen as most preferred

  • 7/28/2019 direct drive.pdf

    11/12www.baldor.com

    Leadership in

    Premium Efciency

    CalledakeybreakthroughbytheConsortiumforEnergyEfciency,theCEEin1998

    recognizedBaldorsSuper-Easthefirstpremiumefcientmotorlinetomeettheir

    stringentefciencycriteria,citingForthersttime,onemanufacturerwillcarryall

    qualifyingproducts.

    MinimumEfciencyPerformanceStandards(MEPS)forelectricmotorsarebecoming

    commonplacethroughouttheworld.TherstofthesewastheEnergyPolicyActof1992

    (EPAct)thatmandatedefciencylevelsfor1-200Hpgeneralpurposemotorsforsalein

    theU.S.afterOctober1997.TheEnergyIndependenceandSecurityActof2007(EISA)

    buildsuponEPActandraisestheefciencylevelforthesemotorstoNEMAPremium

    efciencyaddsothercongurationsand201-500HpratingsforMEPScompliance.

    BaldorRelianceSuper-EmotorsmanufacturedtodaymeetorexceedEISArequirements.

    Ascountriesandregionsacrosstheworldestablishminimumefciencylevelsformotors,

    morecompaniesareturningtotheBaldorRelianceSuper-E.Thisincludesplantand

    processingapplications,aswellasOEMproductsforshipmentoverseas.Super-Emotors

    meetorexceedtheefciencylevelsdenedbyNEMAPremium

    ,EPActintheU.S.,NRCinCanada.CEMEPEFF1inEurope,andthenewIE3levelofIEC60034-30.

    Awideselectionofpremiumefcientmotors,availablefromstock,manufacturedand

    soldbyacompanycommittedtobuildingbetterproductsforindustriesworldwide.No

    wonder,sincethe1920s,BaldorRelianceisrecognizedastheleaderinenergyefcientindustrialmotorsanddrives.

    Making Energy Efciency Work For You

    Why is Energy Efficiency Important?

    Electricmotor-drivensystemsusedinindustrialprocessesconsume63%ofallelectricityusedinU.S.industrialsectoraccordingtoaU.S.DepartmentofEnergyreportpublishedin1998.A2002reportshowsthatcompaniesthatpracticed

    DOEbestpracticesactuallyaveraged33percentsavingsiftheyweretoapplymotorandmotorsystemefficiencyupgrades,includingtheuseofadjustablespeeddrives.Thepotentialpositiveimpactsoncompaniesbottomlinesandtheenvironmentaresignificant.

    Purchase Price is Only a Small Piece of the Pie

    Thepiecharttotherightshowsthetypicallifecyclecostofa100Hpmotoroperatingincontinuousdutyovera20-yearlife.Asyoucansee,theoriginalpurchasepriceisalmostinsignificantcomparedtowhatitwillcosttopowerthemotorduringitsusefullife.

    How Baldor Super-E Efficiencies Compare to Industry Standards

    BaldorslineofSuper-Emotorsofferscustomersthehighestlevelofoverall

    efficienciesavailablefromanymotormanufacturer,meetingorexceedingNEMAPremiumefficiency.

    BE$T Baldor Energy Savings Tool Makes Calculating Payback Easy

    Inordertomakepaybackcalculationseasierforcustomers,BaldordevelopedBE$T,BaldorEnergySavingsTool.Thesoftwarehelpscalculateenergycostandenergysavingsformotors,aswellaspaybacktimeframes.ApopularfeatureofBE$Tisthatitallowsuserstomakehead-to-headcomparisonsofuptothreemotors,givingcustomerstheinformationtomakeaninformeddecisionthroughcomparativeanalysis.

    BE$T,BaldorEnergySavingsToolisavailableasadownloadthroughBaldorsaward-winningWebsite(www.baldor.com/support/software_BEST.asp,)aswellasastand-aloneCD-ROM,availablefromyourBaldorDistrictOffice.

    0

    300

    600

    900

    1200

    $1500

    Electric Motor Efficiency Ratings

    What is Higher Efficiency Worth?

    A Baldor Super-E motor and Inverter Control

    provide premium energy efciency and improvedprocess control to a municipal water treatment

    facility.

  • 7/28/2019 direct drive.pdf

    12/12

    Baldor Electric Company

    BR411

    Printed in U.S.A.

    10/10 TCP 25 000

    BALDOR ELECTRIC COMPANY

    World Headquarters P.O. Box 2400 Fort Smith, AR 72902-2400 U.S.A.Ph: (479) 646-4711 Fax (479) 648-5792 International Fax (479) 648-5895 www.baldor.com

    JAPAN

    DIABLDG802, 2-21-1TSURUYA-CHO, KANAGAWA-KU YOKOHAMA,221-0835,JAPAN PHONE:81-45-412-4506 FAX:81-45-412-4507

    MEXICO

    LEON, gUANAJUATO

    KM.2.0BLVD.AEROPUERTO LEN37545,GUANAJUATO,MXICO PHONE:+524777612030 FAX:+524777612010MIDDLE EAST & NORTH AFRICA

    VSEINTERNATIONALCORP. P.O.BOX5618 BUFFALOGROVE,IL60089-5618 PHONE:8475905547 FAX:8475905587

    PANAMA

    AVE.RICARDOJ.ALFARO EDIFICIOSUNTOWERSMALL PISO2,LOCAL55 CIUDADDEPANAM,PANAM

    PHONE:+507236-5155 FAX:+507236-0591

    SINgAPORE

    18KAKIBUKITROAD3,#03-09 ENTREPRENEURBUSINESSCENTRE SINGAPORE415978 PHONE:(65)67442572 FAX:(65)67471708

    SWITZERLAND

    POSTFACH73 SCHUTZENSTRASSE59 CH-8245FEUERTHALEN SWITZERLAND PHONE:+41526474700 FAX:+41526592394

    TAIWAN

    1F,NO126WENSHAN3RDSTREET, NANTUNDISTRICT, TAICHUNGCITY408 TAIWANR.O.C PHONE:(886)423804235 FAX:(886)423804463

    UNITED KINgDOM

    6BRISTOLDISTRIBUTIONPARK HAWKLEYDRIVE BRISTOLBS320BFU.K. PHONE:+441454850000 FAX:+441454859001

    VENEZUELA

    AV.ROMA.QTAELMILAGRO.URB. CALIFORNIANORTE CARACAS,1070 VENEZUELA PHONE/FAX:+582122727343 MOBILE:+584141148623

    NEW YORK

    AUBURN ONEELLISDRIVE AUBURN,NY13021 PHONE:315-255-3403 FAX:315-253-9923

    NORTH CAROLINA

    gREENSBORO 1220ROTHERWOODROAD GREENSBORO,NC27406 PHONE:336-272-6104 FAX:336-273-6628

    OHIO

    CINCINNATI 2929CRESCENTVILLEROAD WESTCHESTER,OH45069 PHONE:513-771-2600 FAX:513-772-2219

    CLEVELAND 8929FREEWAYDRIVE MACEDONIA,OH44056 PHONE:330-468-4777 FAX:330-468-4778

    OKLAHOMA

    TULSA 7170S.BRADEN,SUITE140 TULSA,OK74136 PHONE:918-366-9320 FAX:918-366-9338

    OREgON

    PORTLAND 20393SWAVERYCOURT TUALATIN,OR97062 PHONE:503-691-9010 FAX:503-691-9012

    PENNSYLVANIA

    PHILADELPHIA

    1035THOMASBUSCH MEMORIALHIGHWAY PENNSAUKEN,NJ08110

    PHONE:856-661-1442 FAX:856-663-6363

    PITTSBURgH

    159PROMINENCEDRIVE NEWKENSINGTON,PA15068 PHONE:724-889-0092 FAX:724-889-0094

    TENNESSEE

    MEMPHIS 4000WINCHESTERROAD MEMPHIS,TN38118 PHONE:901-365-2020 FAX:901-365-3914

    INDIANA

    INDIANAPOLIS 5525W.MINNESOTASTREET INDIANAPOLIS,IN46241 PHONE:317-246-5100 FAX:317-246-5110

    IOWA

    DES MOINES 1800DIXONSTREET,SUITEC DESMOINES,IA50316 PHONE:515-263-6929 FAX:515-263-6515

    MARYLAND

    BALTIMORE

    6660SANTABARBARARD. SUITES22-24 ELKRIDGE,MD21075 PHONE:410-579-2135 FAX:410-579-2677

    MASSACHUSETTS

    BOSTON

    6PULLMANSTREET WORCESTER,MA01606 PHONE:508-854-0708 FAX:508-854-0291

    MICHIgAN

    DETROIT 5993PROGRESSDRIVE STERLINGHEIGHTS,MI48312 PHONE:586-978-9800 FAX:586-978-9969

    MINNESOTA

    MINNEAPOLIS 21080134THAVENUENORTH ROGERS,MN55374

    PHONE:763-428-3633 FAX:763-428-4551

    MISSOURI

    ST LOUIS 422INDUSTRIALDRIVE MARYLANDHEIGHTS,MO63043 PHONE:314-298-1800 FAX:314-298-7660

    KANSAS CITY

    1501BEDFORDAVENUE NORTHKANSASCITY,MO64116 PHONE:816-587-0272 FAX:816-587-3735

    TEXAS

    DALLAS

    2920114THSTREETSUITE100

    GRANDPRAIRIE,TX75050 PHONE:214-634-7271 FAX:214-634-8874

    HOUSTON 10355W.LITTLEYORKROAD SUITE300 HOUSTON,TX77041 PHONE:281-977-6500 FAX:281-977-6510

    UTAH

    SALT LAKE CITY

    2230SOUTHMAINSTREET SALTLAKECITY,UT84115 PHONE:801-832-0127 FAX:801-832-8911

    WISCONSIN

    MILWAUKEE 1960SOUTHCALHOUNROAD NEWBERLIN,WI53151 PHONE:262-784-5940 FAX:262-784-1215

    INTERNATIONAL SALES

    FORT SMITH, AR P.O.BOX2400 FORTSMITH,AR72902 PHONE:479-646-4711 FAX:479-648-5895

    CANADA

    EDMONTON, ALBERTA

    4053-92STREET EDMONTON,ALBERTAT6E6R8 PHONE:780-434-4900 FAX:780-438-2600

    TORONTOOAKVILLE, ONTARIO

    2750COVENTRYROAD OAKVILLE,ONTARIOL6H6R1 PHONE:905-829-3301 FAX:905-829-3302

    MONTREAL, QUEBEC 5155J-ARMANDBOMBARDIER SAINT-HUBERT,QUBEC CANADAJ3Z1G4 PHONE:514-933-2711

    FAX:514-933-8639

    VANCOUVER,

    BRITISH COLUMBIA

    1538KEBETWAY PORTCOQUITLAM, BRITISHCOLUMBIAV3C5M5 PHONE604-421-2822 FAX:604-421-3113

    WINNIPEg, MANITOBA

    54PRINCESSSTREET WINNIPEG,MANITOBAR3B1K2 PHONE:204-942-5205 FAX:204-956-4251

    AUSTRALIA

    UNIT3,6STANTONROAD SEVENHILLS,NSW2147,AUSTRALIA PHONE:(61)(2)96745455 FAX:(61)(2)96742495

    UNIT8,5KELLETTSROAD ROWVILLE,VICTORIA,3178AUSTRALIA PHONE:(61)(3)97534355 FAX:(61)(3)97534366

    EL SALVADOR

    RESIDENCIALPINARESDESUIZA POL.15#44, NVA.SANSALVADOR,ELSALVADOR PHONE:+5032288-1519 FAX:+5032288-1518

    CHILE

    LUISTHAYEROJEDA166, OF402-PROVIDENCIA SANTIAGO,CHILE PHONE:+5628169900

    CHINA

    160SONGSHENGROAD SONGJIANGINDUSTRYZONE SHANGHAI201613,CHINA PHONE:+862157605335 FAX:+862157605336

    gERMANY

    HERMANN-HEINRICH-GOSSEN3 50858KOLN,GERMANY PHONE:49-2234379410 FAX:49-22343794164

    DIESELSTRASSE22 D-85551KIRCHHEIM MUNICH,GERMANY PHONE:+4989905080 FAX:+498990508492

    INDIA

    14,COMMERCEAVENUE MAHAGANESHCOLONY PAUDROAD PUNE-411038 MAHARASHTRA,INDIA PHONE:+912025452717/18

    FAX:+912025452719

    INDONESIA

    TALAVERAOFFICEPARK, 28THFLOOR,SUITEM18 JI.T.B.SIMATUPANG,KAV.22-26 JAKARTA12430,INDONESIA PHONE:+622175999879 FAX:+622175999878

    ITALY

    VIASOTTOBISIO30 BALERNACH-6828 PHONE:+41916836161 FAX:+41916302633

    UNITED STATES

    ARIZONA

    PHOENIX 4211S43RDPLACE PHOENIX,AZ85040 PHONE:602-470-0407 FAX:602-470-0464

    ARKANSAS

    CLARKSVILLE 1001COLLEGEAVENUE CLARKSVILLE,AR72830 PHONE:479-754-9108 FAX:479-754-9205

    CALIFORNIA

    LOS ANgELES 6480FLOTILLASTREET COMMERCE,CA90040 PHONE:323-724-6771 FAX:323-721-5859

    HAYWARD 21056FORBESAVENUE HAYWARD,CA94545 PHONE:510-785-9900 FAX:510-785-9910

    COLORADO

    DENVER 3855FORESTSTREET DENVER,CO80207 PHONE:303-623-0127 FAX:303-595-3772

    CONNECTICUT

    WALLINgFORD 65SOUTHTURNPIKEROAD WALLINGFORD,CT06492 PHONE:203-269-1354 FAX:203-269-5485

    FLORIDA

    TAMPA/PUERTO RICO/VIRgIN ISLANDS

    3906EAST11THAVENUE TAMPA,FL33605 PHONE:813-248-5078

    FAX:813-247-2984

    gEORgIA

    ATLANTA 62TECHNOLOGYDRIVE ALPHARETTA,GA30005 PHONE:770-772-7000 FAX:770-772-7200

    ILLINOIS

    CHICAgO 340REMINGTONBLVD. BOLINGBROOK,IL60440 PHONE:630-296-1400 FAX:630-226-9420

    EDMONTONVANCOUVER

    DISTRICT OFFICE& WAREHOUSES

    PORTLAND

    HAYWARD

    LOS ANELES

    PHOENIX

    MONTERREY

    UADALAJARA

    TAMPA

    FORTSMITH

    MEMPHIS

    WINNIPE

    ATLANTA

    KANSAS CITY

    ST LOUIS

    DENVERDES MOINES

    REENSBORO

    BALTIMORE

    PITTSBURH

    CINCINNATI

    INDIANAPOLIS

    DALLAS

    CHICAO

    PHILADELPHIA

    NEW YORK

    BOSTONAUBURN

    CLEVELAND

    DETROIT

    TORONTOMINNEAPOLIS

    MILWAUKEE

    SALT LAKE CITY

    TULSA

    MONTREAL

    HOUSTON

    LEON

    WALLINFORD

    CLARKSVILLE

    MEXICO CITY

    BALDOR SALES OFFICES


Recommended