AWe keep power under control.
Distribution EquipmentShort Form Catalogue 2007–2008
www.moeller.co.uk
2
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
3
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Distribution Equipment Short Form CatalogueIntroduction
Moeller Electric LtdMoeller Electric is a world renowned innovator and supplier of components for industrial automation and power distribution applications. Founded in 1899, Moeller has always been at the forefront of electrical innovation.
A global player with a turnover in excess of £680 million, Moeller has extensive experience, a customer-focused approach and continued investment in developing both its products and employees. Moeller continues to set new standards in the industry.
With 350 sales offices in more than 80 countries, Moeller is well placed to meet the needs of customers and end users wherever they are. But Moeller is not just selling locally; it is also a local producer. One of Moeller’s 36 production plants is situated in the UK at Worksop where it produces rotary cam switches and switch disconnectors.
The UK headquarters, in AylesburyMoeller in the UK – Known for Quality and Value for 50 years
Moeller opened its first office in the UK in 1957 and has always been associated with high quality products, well engineered solutions and responding to customer needs. Moeller’s UK distribution centre, where over 3,500 line items are held in stock, is also the central location for:
sales and sales support
technical support
finanace and credit control
marketing and UK product management
Distribution EquipmentMoeller’s Distribution Equipment Division provides circuit protection and building control products from 0.5 Amps to 4,000 Amps. From single devices through to type tested switchboards, Moeller’s range is comprehensive.
Founded in 1874, and now part of the Moeller group, F&G developed the world’s first voltage operated Earth Leakage Circuit Breaker, and RCCB technology as we know it today. Followed by fast, modern RCDs and RCBOs, Moeller now licence their RCD technology to many of the world’s leading electrical companies. Over 30 million poles for circuit protection devices are produced each year at just one of the five Moeller circuit protection manufacturing plants in Europe.
To efficiently service the needs of electrical contractors and end users, Moeller’s team of Distribution Equipment Sales Engineers work in partnership with the national network of a hundred Key Stockists.
Moeller’s Technical Support staff are on hand to help select the right component for an application. In-depth product support is provided by technically biased Product Management, working closely with engineers and factories in Austria.
Industrial AutomationWith over 100 years’ experience in motor control, Moeller have developed a full line of automation control products – from contactors and front-of-panel control devices to variable speed drives, soft starts, PLCs and HMIs, as well as the market leading easy relays. For full details of Moeller’s range of industrial switchgear, please call our Literature Line on 01296 310321.
Intr
oduc
tion
Use this catalogue to select the products you require, then just contact your nearest Moeller Stockist, who will be happy to take your order. (Call 01296 397400 for details of your nearest stockist.)
2
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
3
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Distribution Equipment Short Form CatalogueContents
Cont
ents
XBoard Consumer Units 4
A & B TypeMCB Distribution Boards 11
Mini Panel Boards 22
MCCB Panel Boards 31
Enclosed Switch Fuses 42
Enclosed MCCBs 45
Enclosed Switch Disconnectors 46
Enclosed Starters 49
Enclosures 53
Miniature Circuit Breakers (MCBs) 65
Residual Current Devices (RCDs) 83
Combined RCD/MCBs (RCBOs) 97
MCCBs and Disconnects 103
Control and Switching 113
Surge Protection 117
Fuse Protection 129
Busbar Systems 130
xEnergy Switchboards 133
4
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
XBoa
rd C
onsu
mer
Uni
ts5
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
XBoa
rd C
onsu
mer
Uni
ts
XBoard Consumer UnitsIntroduction
XBoard Consumer UnitsStylish and easy to fi t, the Moeller range of insulated and metal Consumer Units has been designed in accordance with EN 60439-3.
A full and extensive range of outgoing devices are available to meet all possible application needs from MCBs, RCBOs, RCDs to DIN mountable control devices.
4
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
XBoa
rd C
onsu
mer
Uni
ts
5
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
XBoa
rd C
onsu
mer
Uni
ts
XBoard Consumer UnitsInsulated
2-Pole · Main Switch Controlled
Outgoing Ways Rated Current In (A) Dimensions (mm) Width Height Depth Part Number
2 100 172 225 111 BC-P2
6 100 244 225 111 BC-P6
10 100 316 225 111 BC-P10
12 100 351 225 111 BC-P12
18 100 457 225 111 BC-P18
2-Pole · RCD Controlled
Type Outgoing Ways Rated Current In (A) Dimensions (mm) Width Height Depth Part Number
30 mA RCD-controlled 2 40 172 225 111 BC-P2R40
2 63 172 225 111 BC-P2R63
6 63 244 225 111 BC-P6R63
6 80 244 225 111 BC-P6R80
6 100 244 225 111 BC-P6R100
10 63 316 225 111 BC-P10R63
10 80 316 225 111 BC-P10R80
10 100 316 225 111 BC-P10R100
12 63 351 225 111 BC-P12R63
12 80 351 225 111 BC-P12R80
12 100 351 225 111 BC-P12R100
18 80 457 225 111 BC-P18R80
18 100 457 225 111 BC-P18R100
100 mA time-delayedRCD (Type G)
12 100 351 225 111 BC-P12R100G
18 100 457 225 111 BC-P18R100G
Split Load · 2-Pole · 100 A Main Switch / 30 mA RCD Controlled
Outgoing Ways RCD Ways Available* Rated Current In (A) Dimensions (mm) Width Height Depth Part Number
8 1–7 63 316 225 111 BC-P8SR63
8 1–7 80 316 225 111 BC-P8SR80
10 1–9 63 351 225 111 BC-P10SR63
10 1–9 80 351 225 111 BC-P10SR80
16 1–15 80 457 225 111 BC-P16SR80
Note * number of freely configurable RCD protected ways.
Dual Tariff · 2 x 2-Pole Main Switch Controlled
Outgoing Ways Rated Current In (A) Dimensions (mm) Width Height Depth Part Number
10 100 351 225 111 BC-P10SS
16 100 457 225 111 BC-P16SS
6
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
XBoa
rd C
onsu
mer
Uni
ts7
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
XBoa
rd C
onsu
mer
Uni
ts
2-Pole · Main Switch Controlled
Outgoing Ways Rated current In (A) Dimensions (mm) Width Height Depth Part Number
2 100 180 223 113 BC-M2
6 100 252 223 113 BC-M6
10 100 324 223 113 BC-M10
12 100 359 223 113 BC-M12
18 100 465 223 113 BC-M18
2-Pole · RCD Controlled
Type Outgoing Ways Rated Current In (A) Dimensions (mm) Width Height Depth Part Number
30 mA RCD-controlled 2 40 180 223 113 BC-M2R40
2 63 180 223 113 BC-M2R63
6 63 252 223 113 BC-M6R63
6 80 252 223 113 BC-M6R80
6 100 252 223 113 BC-M6R100
10 63 324 223 113 BC-M10R63
10 80 324 223 113 BC-M10R80
10 100 324 223 113 BC-M10R100
12 63 359 223 113 BC-M12R63
12 80 359 223 113 BC-M12R80
12 100 359 223 113 BC-M12R100
18 80 465 223 113 BC-M18R80
18 100 465 223 113 BC-M18R100
100 mA time-delayedRCD (Type G)
12 100 359 223 113 BC-M12R100G
18 100 465 223 113 BC-M18R100G
Split Load · 2-Pole · 100 A Main Switch / 30 mA RCD Controlled
Outgoing Ways RCD Ways Available* Rated Current In (A) Dimensions (mm) Width Height Depth Part Number
8 1–7 63 324 223 113 BC-M8SR63
8 1–7 80 324 223 113 BC-M8SR80
10 1–9 63 359 223 113 BC-M10SR63
10 1–9 80 359 223 113 BC-M10SR80
16 1–15 80 465 223 113 BC-M16SR80
Note * number of freely configurable RCD protected ways.
Dual Tariff · 2 x 2-Pole Main Switch Controlled
Outgoing Ways Rated Current In (A) Dimensions (mm) Width Height Depth Part Number
10 100 359 223 113 BC-M10SS
16 100 465 223 113 BC-M16SS
XBoard Consumer UnitsMetal
6
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
XBoa
rd C
onsu
mer
Uni
ts
7
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
XBoa
rd C
onsu
mer
Uni
ts
Miniature Circuit Breakerssingle-pole · 6 kA
Rated Current In (A) B Curve C Curve
2 PLS6-B2 PLS6-C2
6 PLS6-B6 PLS6-C6
10 PLS6-B10 PLS6-C10
13 PLS6-B13 PLS6-C13
16 PLS6-B16 PLS6-C16
20 PLS6-B20 PLS6-C20
25 PLS6-B25 PLS6-C25
32 PLS6-B32 PLS6-C32
40 PLS6-B40 PLS6-C40
50 PLS6-B50 PLS6-C50
63 PLS6-B63 PLS6-C63
Combined RCD/MCB (RCBO)single-pole + Neutral · conditionally surge current proof 250 A · B & C curve · type AC
Rated Current In (A) Type / Tripping CurrentB Curve · 30 mA B Curve · 100 mA C Curve · 30 mA C Curve · 100 mA
6 PKS6-6/1N/B/003 PKS6-6/1N/B/01 PKS6-6/1N/C/003 PKS6-6/1N/C/01
10 PKS6-10/1N/B/003 PKS6-10/1N/B/01 PKS6-10/1N/C/003 PKS6-10/1N/C/01
13 PKS6-13/1N/B/003 PKS6-13/1N/B/01 PKS6-13/1N/C/003 PKS6-13/1N/C/01
16 PKS6-16/1N/B/003 PKS6-16/1N/B/01 PKS6-16/1N/C/003 PKS6-16/1N/C/01
20 PKS6-20/1N/B/003 PKS6-20/1N/B/01 PKS6-20/1N/C/003 PKS6-20/1N/C/01
25 PKS6-25/1N/B/003 PKS6-25/1N/B/01 PKS6-25/1N/C/003 PKS6-25/1N/C/01
32 PKS6-32/1N/B/003 PKS6-32/1N/B/01 PKS6-32/1N/C/003 PKS6-32/1N/C/01
40 PKS6-40/1N/B/003 PKS6-40/1N/B/01 PKS6-40/1N/C/003 PKS6-40/1N/C/01
Main Incoming Switch · 2-Pole · 10 kA
Rated Current In (A) Part Number
63 IS-63/2
80 IS-80/2
100 IS-100/2
125 IS-125/2
Garage Units · IP552 outgoing ways
Rated Current In (A) MCB Ratings (A) (A)
Dimensions (mm) Width Height Depth Part Number
RCD 40 16 6 120 192 105 BC-G3R40/16/6
RCD 63 32 6 120 192 105 BC-G3R63/32/6
INC 100 16 6 120 192 105 BC-G3/16/6
RCD 40 – – 120 192 105 BC-G3R40
RCD 63 – – 120 192 105 BC-G3R63
INC 100 – – 120 192 105 BC-G3
XBoard Consumer UnitsIncoming and Outgoing Devices
Outgoing Devices
Incoming Devices
8
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
XBoa
rd C
onsu
mer
Uni
ts9
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
XBoa
rd C
onsu
mer
Uni
ts
Standard AC RCDs · 2-Pole
Rated Current In (A) Tripping Current30 mA 100 mA 300 mA 500 mA
16 * PFIM-16/2/001 – – –
25 PFIM-25/2/003 PFIM-25/2/01 PFIM-25/2/03 PFIM-25/2/05
40 PFIM-40/2/003 PFIM-40/2/01 PFIM-40/2/03 PFIM-40/2/05
63 PFIM-63/2/003 PFIM-63/2/01 PFIM-63/2/03 PFIM-63/2/05
80 PFIM-80/2/003 PFIM-80/2/01 PFIM-80/2/03 PFIM-80/2/05
100 PFIM-100/2/003 PFIM-100/2/01 PFIM-100/2/03 PFIM-100/2/05
Note * 16 A RCD is rated for 10 mA earth leakage.
Standard AC RCDs · 4-Pole
Rated Current In (A) Tripping Current30 mA 100 mA 300 mA 500 mA
25 PFIM-25/4/003 PFIM-25/4/01 PFIM-25/4/03 PFIM-25/4/05
40 PFIM-40/4/003 PFIM-40/4/01 PFIM-40/4/03 PFIM-40/4/05
63 PFIM-63/4/003 PFIM-63/4/01 PFIM-63/4/03 PFIM-63/4/05
80 PFIM-80/4/003 PFIM-80/4/01 PFIM-80/4/03 PFIM-80/4/05
100 PFIM-100/4/003 PFIM-100/4/01 PFIM-100/4/03 PFIM-100/4/05
Installation Relays
Control Voltage Rated Current AC1 (A) Contacts Module Width Part Number
230 V AC 20 1 N/O 1 Z-RE230/S
20 2 N/O 1 Z-RE230/SS
20 1 N/O + 1 N/C 1 Z-RE230/SO
24 V AC 20 2 N/O 1 Z-RE24/SS
20 1 N/O + 1 N/C 1 Z-RE24/SO
24 V DC 20 2 N/O + 2 N/C 2 Z-RE23/2S20
Installation Contactors
Control Voltage Rated Current AC1 (A) Contacts Module Width Part Number
230 V AC 25 4 N/O 2 Z-SCH230/25-40
4 N/C 2 Z-SCH230/25-04
3 N/O + 1 N/C 2 Z-SCH230/25-31
2 N/O + 2 NC 2 Z-SCH230/25-22
40 4 N/O 4 Z-SCH230/40-40
3 N/O + 1 N/C 4 Z-SCH230/40-31
2 N/O + 2 NC 4 Z-SCH230/40-22
2 N/O 4 Z-SCH230/40-20
63 4 N/O 4 Z-SCH230/63-40
3 N/O + 1 N/C 4 Z-SCH230/63-31
2 N/O + 2 NC 4 Z-SCH230/63-22
2 N/O 4 Z-SCH230/63-20
24 V AC 25 4 N/O 2 Z-SCH24/25-40
2 N/O + 2 NC 2 Z-SCH24/25-22
XBoard Consumer UnitsRCDs · Control and Switching DIN Mounted Devices
8
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
XBoa
rd C
onsu
mer
Uni
ts
9
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
XBoa
rd C
onsu
mer
Uni
ts
Analogue Time Switch
Drive Program Contacts Chan/Mod Part Number
Synchronous Day 1 N/O 1/1 Z-SGS/TA
Day 1 C/O 1/3 SU-GS/1W-TA
Week 1 C/O 1/3 SU-GS/1W-WO
Quartz Day 1 N/O 1/1 SU-CQ-TA
Day 1 C/O 1/3 SU-CQ/1W-A
Week 1 C/O 1/3 SU-CQ/1W-WO
Day + Week 2 C/O 2/6 SU-CQ/2W-TW
Digital Time Switch
Drive Program Contacts Chan/Mod Part Number
Quartz Day 1 C/O 1/2 Z-SDM/1K-TA
Week 1 C/O 1/2 Z-SDM/1K-WO
Week 2 C/O 2/2 Z-SDM/2K-WO
Signalling Devices
Function Voltage (V AC) Module Width Part Number
Buzzer 12 1 Z-SUM12
24 1 Z-SUM24
230 1 Z-SUM230
Bell 12 1 Z-GLO12
24 1 Z-GLO24
230 1 Z-GLO230
Light Intensity Switch
Function Rated Current AC1 (A) Contacts Module Width Part Number
DIN rail mount 16 1 N/O 1 DS-GS/1S
DIN rail mount 16 1 C/O + Timer 3 DS-GS/1W
Outdoor installation 10 1 N/O – DS-GK
Spare sensor for DS–DG – – – Z-DS/SENSOR
Cap for daylight 100–10,000 lux – – – Z-DS/KAPPE
Staircase Switch
Function Rated Current AC1 (A) Contacts Module Width Part Number
with stop function 16 1C/O 1 TLE
stop & alarm function 16 1C/O 1 TLK
XBoard Consumer UnitsControl and Switching DIN Mounted Devices
10
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
XBoa
rd C
onsu
mer
Uni
ts11
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCB
Dis
trib
utio
n Bo
ards
· A
& B
Typ
eTransformers · 230 V AC
Description SecondaryVoltage (V)
SecondaryCurrent (A) Module Width Part Number
Bell (8 VA) 8 1 2 TR-G/8
4–8–12 1–1–0.67 2 TR-G3/8
8 1 2 TR-G/8-S *
Bell (18 VA) 4–8–12 2–2–1.5 2 TR-G3/18
12–24 2–1 3 TR-G2/24
Note * TR-G/8-S has primary switch.
Busbar Comb with Fork Connectors1 metre length
Description Poles Rating Part Number
Busbar block 1 63 A Z–GV–10/1P–1TE
3 63 A Z–GV–10/3P–3TE
1 80 A Z–GV–16/1P–1TE
3 80 A Z–GV–16/3P–3TE
End cover cap 2+3 63 A Z–AK–10/2+3P
2+3 80 A Z–AK–16/2+3P
XBoard Consumer UnitsControl and Switching DIN Mounted Devices · Busbars
Fuse Basessingle-pole · complete with fuse gG (gL)
Rated Current (A) Fuse Size (mm) Part Number
10 8.5 x 23 SGD/10/1
16 10.3 x 25.8 SGD/16/1
20 8.5 x 31.5 SGD/20/1
32 10.3 x 38 SGD/32/1
Cable Sets for Split Board Conversioncontains 1 Live and 2 Neutral cables
For use with Part Number
10 & 12 way boards BCZ-PM-CS12
18 way boards BCZ-PM-CS18
10
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
XBoa
rd C
onsu
mer
Uni
ts
11
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCB
Dis
trib
utio
n Bo
ards
· A
& B
Typ
e
A & B Type MCB Distribution BoardsIntroduction
A & B Type MCB Distribution BoardsMoeller’s single-phase and three-phase MCB Distribution Board range has been developed to meet the needs of UK specifi ers, electrical contractors and distributors. The resulting high quality, value-for-money board is versatile and easy to install, conforming to the latest British, European and international standards, with the option to incorporate energy metering.
12
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCB
Dis
trib
utio
n Bo
ards
· A
& B
Typ
e13
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCB
Dis
trib
utio
n Bo
ards
· A
& B
Typ
eA Type · Single Phase with 125 A Busbar
Outgoing Ways Dimensions (mm) Width Height Depth Part Number
6 220 285 150 FG-A-06
12 330 285 150 FG-A-12
19 480 285 150 FG-A-19
Main Incoming Switch · 2-Pole · 10 kA
Rated Current In (A) Part Number
63 IS-63/2
80 IS-80/2
100 IS-100/2
125 IS-125/2
RCDs · 2-Pole · Standard AC
Rated Current In (A) Tripping Current30 mA 100 mA 300 mA 500 mA
80 PFIM-80/2/003 PFIM-80/2/01 PFIM-80/2/03 PFIM-80/2/05
100 PFIM-100/2/003 PFIM-100/2/01 PFIM-100/2/03 –
Single-Pole Miniature Circuit Breakers · 10 kA · IEC 60897
Rated Current In (A) B Curve C Curve D Curve
6 PLSM-B6 PLSM-C6 PLSM-D6
10 PLSM-B10 PLSM-C10 PLSM-D10
16 PLSM-B16 PLSM-C16 PLSM-D16
20 PLSM-B20 PLSM-C20 PLSM-D20
25 PLSM-B25 PLSM-C25 PLSM-D25
32 PLSM-B32 PLSM-C32 PLSM-D32
40 PLSM-B40 PLSM-C40 PLSM-D40
50 PLSM-B50 PLSM-C50 PLSM-D50 *
63 PLSM-B63 PLSM-C63 PLSM-D63 *
Note * PLSM-D50 and D63 available July 2007.
MCB Distribution BoardsA Type
Toggle Colours
2 A 4 A 6 A 10 A 13 A 16 A
20 A 25 A 32 A 40 A 50 A 63 A
12
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCB
Dis
trib
utio
n Bo
ards
· A
& B
Typ
e
13
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCB
Dis
trib
utio
n Bo
ards
· A
& B
Typ
eB Type · Three Phase with 250 A Busbar
Outgoing Ways Dimensions (mm) Width Height Depth Part Number
4 460 595 155 FG-B-04
6 460 595 155 FG-B-06
8 460 870 155 FG-B-08
12 460 870 155 FG-B-12
18 460 1145 155 FG-B-18
24 460 1145 155 FG-B-24
Main Incoming Switch · 10 kA
Number of Poles Rated Current (In)100 A 125 A
2 IS-100/2 IS-125/2
3 IS-100/3 IS-125/3
4 IS-100/4 IS-125/4
RCDs · 4-Pole · Standard AC
Rated Current In (A) Tripping Current30 mA 100 mA 300 mA 500 mA
80 PFIM-80/4/003 PFIM-80/4/01 PFIM-80/4/03 PFIM-80/4/05
100 PFIM-100/4/003 PFIM-100/4/01 PFIM-100/4/03 PFIM-100/4/05
MCB Distribution BoardsB Type
Neutral Link Kit
Description Used on range Part Number
Kit for installing Neutral link for 2- and 4-pole incomers FG-B FG-B/K-4
Adapter Kit
Description Used on range Part Number
Adapter kit to convert a TP&N board to a SP&N board FG-B FG-TP/SP
Incomer Enclosure · supplied with connection leads
Rated Current (A) Used on range Description Part Number
160 FG-B Incomer enclosure for 4 and 24 way FG-B/INC-160
250 FG-B Incomer enclosure for 4 and 24 way FG-B/INC-250
14
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCB
Dis
trib
utio
n Bo
ards
· A
& B
Typ
e15
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCB
Dis
trib
utio
n Bo
ards
· A
& B
Typ
e
MCB Distribution BoardsIncoming Devices · Energy Metering
Incoming Devices · 25 kA
Rated Current (A) For use with Description Part Number
160 FG-B/INC-160 Switch Disconnector PN1-160
Moulded Case Circuit Breaker LZMB1-A160
250 FG-B/INC-250 Switch Disconnector PN2-250
Moulded Case Circuit Breaker LZMB2-A250
Energy Metering Section Enclosure
Description Part Number
Enclosure with cut-out for 96 x 96 meter and DIN rail FG-B/MB
Note Requires cable sets for connecting MCCB incomer with single or split-load boards.
Cable Setsfor use with single metering section and split-load metering sections · used on range FG-B
Description For use with Part Number
Meter box cable set LZMB1/PN1 FG-B/MBCS-160
LZMB2/PN2 FG-B/MBCS-250
Meter box split cable set LZMB1/PN1 FG-B/MBSCS-160
LZMB2/PN2 FG-B/MBSCS-250
Energy Meters
Description Part Number
Multifunction energy meter KWH/A20
Multifunction energy meter, facility for harmonics measuring KWH/A40
Note Energy meters are enabled for the following add-on modules:A20 and A40: modbus 485 communication module, pulse output module;
A40: harmonics module, analogue module, profibus module, i/o module.Please contact your local sales engineer for the additional options.
Metering Connection Kits
Description Part Number
Wiring loom for CT, voltage and supply connections KWH/CBLB
DIN rail fuses for supply and voltage inputs, for 1 energy meter KWH/DINB
Earth common connection links for CTs, for 1 energy meter KWH/CTEB
Earth cable from CT to enclosure KWH/CTEARTH
Metering Kitcurrent transformers (see below) to be ordered separately
Description Part Number
Includes enclosure, connection kits and KWH/A20 meter KWH/BKIT
Metering Current Transformers
Description Part Number
Selected based on maximum full-load current to be measured CT-SET (***)
Note Add full-load current value in brackets (***).Please contact your local sales engineer for the options.
14
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCB
Dis
trib
utio
n Bo
ards
· A
& B
Typ
e
15
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCB
Dis
trib
utio
n Bo
ards
· A
& B
Typ
eSingle-Pole Miniature Circuit Breakers · 10kA · IEC 60898
Rated Current In (A) B Curve C Curve D Curve
6 PLSM-B6 PLSM-C6 PLSM-D6
10 PLSM-B10 PLSM-C10 PLSM-D10
16 PLSM-B16 PLSM-C16 PLSM-D16
20 PLSM-B20 PLSM-C20 PLSM-D20
25 PLSM-B25 PLSM-C25 PLSM-D25
32 PLSM-B32 PLSM-C32 PLSM-D32
40 PLSM-B40 PLSM-C40 PLSM-D40
50 PLSM-B50 PLSM-C50 PLSM-D50 *
63 PLSM-B63 PLSM-C63 PLSM-D63 *
Note * PLSM-D50 and -D63 available July 2007.
Double-Pole Miniature Circuit Breakers · 10kA · IEC 60898
Rated Current In (A) B Curve C Curve D Curve
6 PLSM-B6/2 PLSM-C6/2 PLSM-D6/2
10 PLSM-B10/2 PLSM-C10/2 PLSM-D10/2
16 PLSM-B16/2 PLSM-C16/2 PLSM-D16/2
20 PLSM-B20/2 PLSM-C20/2 PLSM-D20/2
25 PLSM-B25/2 PLSM-C25/2 PLSM-D25/2
32 PLSM-B32/2 PLSM-C32/2 PLSM-D32/2
40 PLSM-B40/2 PLSM-C40/2 PLSM-D40/2
50 PLSM-B50/2 PLSM-C50/2 PLSM-D50/2 *
63 PLSM-B63/2 PLSM-C63/2 PLSM-D63/2 *
Note * PLSM-D50/2 and -D63/2 available July 2007.
Triple-Pole Miniature Circuit Breakers · 10 kA · IEC 60898
Rated Current In (A) B Curve C Curve D Curve
6 PLSM-B6/3 PLSM-C6/3 PLSM-D6/3
10 PLSM-B10/3 PLSM-C10/3 PLSM-D10/3
16 PLSM-B16/3 PLSM-C16/3 PLSM-D16/3
20 PLSM-B20/3 PLSM-C20/3 PLSM-D20/3
25 PLSM-B25/3 PLSM-C25/3 PLSM-D25/3
32 PLSM-B32/3 PLSM-C32/3 PLSM-D32/3
40 PLSM-B40/3 PLSM-C40/3 PLSM-D40/3
50 PLSM-B50/3 PLSM-C50/3 PLSM-D50/3 *
63 PLSM-B63/3 PLSM-C63/3 PLSM-D63/3 *
Note * PLSM-D50/3 and -D63/3 available July 2007.
Toggle Colours
MCB Distribution BoardsOutgoing Devices
2 A 4 A 6 A 10 A 13 A 16 A
20 A 25 A 32 A 40 A 50 A 63 A
16
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCB
Dis
trib
utio
n Bo
ards
· A
& B
Typ
e17
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCB
Dis
trib
utio
n Bo
ards
· A
& B
Typ
e
MCB Distribution BoardsOutgoing Devices
Combined RCD/MCB (RCBO) · Single Module (1+N) · B Curve
Rated Current In (A) Tripping Current10 mA 30 mA 100 mA 300 mA
6 PKS6-6/1N/B/001 PKS6-6/1N/B/003 PKS6-6/1N/B/01 PKS6-6/1N/B/03
10 PKS6-10/1N/B/001 PKS6-10/1N/B/003 PKS6-10/1N/B/01 PKS6-10/1N/B/03
16 PKS6-16/1N/B/001 PKS6-16/1N/B/003 PKS6-16/1N/B/01 PKS6-16/1N/B/03
20 PKS6-20/1N/B/001 PKS6-20/1N/B/003 PKS6-20/1N/B/01 PKS6-20/1N/B/03
25 PKS6-25/1N/B/001 PKS6-25/1N/B/003 PKS6-25/1N/B/01 PKS6-25/1N/B/03
32 PKS6-32/1N/B/001 PKS6-32/1N/B/003 PKS6-32/1N/B/01 PKS6-32/1N/B/03
40 PKS6-40/1N/B/001 PKS6-40/1N/B/003 PKS6-40/1N/B/01 PKS6-40/1N/B/03
Combined RCD/MCB (RCBO) · Single Module (1+N) · C Curve
Rated Current In (A) Tripping Current10 mA 30 mA 100 mA 300 mA
6 PKS6-6/1N/C/001 PKS6-6/1N/C/003 PKS6-6/1N/C/01 PKS6-6/1N/C/03
10 PKS6-10/1N/C/001 PKS6-10/1N/C/003 PKS6-10/1N/C/01 PKS6-10/1N/C/03
16 PKS6-16/1N/C/001 PKS6-16/1N/C/003 PKS6-16/1N/C/01 PKS6-16/1N/C/03
20 PKS6-20/1N/C/001 PKS6-20/1N/C/003 PKS6-20/1N/C/01 PKS6-20/1N/C/03
25 PKS6-25/1N/C/001 PKS6-25/1N/C/003 PKS6-25/1N/C/01 PKS6-25/1N/C/03
32 PKS6-32/1N/C/001 PKS6-32/1N/C/003 PKS6-32/1N/C/01 PKS6-32/1N/C/03
40 PKS6-40/1N/C/001 PKS6-40/1N/C/003 PKS6-40/1N/C/01 PKS6-40/1N/C/03
Combined RCD/MCB (RCBO) · Single Module (1+N) · D Curve
Rated Current In (A) Tripping Current10 mA 30 mA 100 mA 300 mA
6 PKS6-6/1N/D/001 – – –
10 PKS6-10/1N/D/001 – – –
16 PKS6-16/1N/D/001 – – –
20 PKS6-20/1N/D/001 – – –
16
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCB
Dis
trib
utio
n Bo
ards
· A
& B
Typ
e
17
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCB
Dis
trib
utio
n Bo
ards
· A
& B
Typ
e
Busbar Kit for N, PE and Clean PE
Description Part Number
2 x 13 terminal FG-BTS-04/06
2 x 22 terminal FG-BTS-08/12
2 x 40 terminal FG-BTS-18/24
Accessories for FG-A/FG-B
Description Part Number
Lock and key FG-DOORLOCK
Busbar tag shroud FG-BTS
Blanking strips (6 modules) AP-45-W
Modular Service Box with DIN Railcomplete with Earth and Neutral terminal bars
Description Neutral andEarth Terminal
Dimensions (mm) Width Height Depth Part Number
8 module DIN rail 7 + 7 214 286 146 FG-MS-06
14 module DIN rail 13 + 13 323 286 146 FG-MS-12
21 module DIN rail 22 + 22 437 286 146 FG-MS-19
Spreader Boxes (without door)
Description Dimensions (mm) Width Height Depth Part Number
Small 459 284 117 FG-B/ES
Large 459 560 117 FG-B/EX
Glazed Door
Used on range Part Number
FG-B-04, FG-B-06 FG-B/GD-04/06
FG-B-08, FG-B-12 FG-B/GD-08/12
FG-B-18, FG-B-24 FG-B/GD-18/24
MCB Distribution BoardsAccessories
18
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCB
Dis
trib
utio
n Bo
ards
· A
& B
Typ
e19
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCB
Dis
trib
utio
n Bo
ards
· A
& B
Typ
eInstallation Relays
Control Voltage Rated Current AC1 (A) Contacts Module Width Part Number
230 V AC 20 1 N/O 1 Z-RE230/S
20 2 N/O 1 Z-RE230/SS
20 1 N/O + 1 N/C 1 Z-RE230/SO
24 V AC 20 2 N/O 1 Z-RE24/SS
20 1 N/O + 1 N/C 1 Z-RE24/SO
24 V DC 20 2 N/O + 2 N/C 2 Z-RE23/2S20
Installation Contactors
Control Voltage Rated Current AC1 (A) Contacts Module Width Part Number
230 V AC 25 4 N/O 2 Z-SCH230/25-40
4 N/C 2 Z-SCH230/25-04
3 N/O + 1 N/C 2 Z-SCH230/25-31
2 N/O + 2 N/C 2 Z-SCH230/25-22
40 4 N/O 4 Z-SCH230/40-40
3 N/O + 1 N/C 4 Z-SCH230/40-31
2 N/O + 2 N/C 4 Z-SCH230/40-22
2 N/O 4 Z-SCH230/40-20
63 4 N/O 4 Z-SCH230/63-40
3 N/O + 1 N/C 4 Z-SCH230/63-31
2 N/O + 2 N/C 4 Z-SCH230/63-22
2 N/O 4 Z-SCH230/63-20
24 V AC 25 4 N/O 2 Z-SCH24/25-40
2 N/O + 2 N/C 2 Z-SCH24/25-22
Light Intensity Switch
Function Rated Current AC1 (A) Contacts Module Width Part Number
DIN rail mount 16 1 N/O 1 DS–GS/1S
DIN rail mount 16 1 C/O + Timer 3 DS–GS/1W
Outdoor installation 10 1 N/O – DS–GK
Spare sensor for DS–DG – – – Z–DS/SENSOR
Cap for daylight 100–10,000 lux – – – Z–DS/KAPPE
Staircase Switch
Function Rated Current AC1 (A) Contacts Module Width Part Number
with stop function 16 1 C/O 1 TLE
stop & alarm function 16 1 C/O 1 TLK
MCB Distribution BoardsControl and Switching DIN Mounted Devices
18
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCB
Dis
trib
utio
n Bo
ards
· A
& B
Typ
e
19
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCB
Dis
trib
utio
n Bo
ards
· A
& B
Typ
e
MCB Distribution BoardsControl and Switching DIN Mounted Devices
Analogue Time Switch
Drive Program Contacts Chan/Mod Part Number
Synchronous Day 1 N/O 1/1 Z-SGS/TA
Day 1 C/O 1/3 SU-GS/1W-TA
Week 1 C/O 1/3 SU-GS/1W-WO
Quartz Day 1 N/O 1/1 SU-CQ-TA
Day 1 C/O 1/3 SU-CQ/1W-A
Week 1 C/O 1/3 SU-CQ/1W-WO
Day + Week 2 C/O 2/6 SU-CQ/2W-TW
Digital Time Switch
Drive Program Contacts Chan/Mod Part Number
Quartz Day 1 C/O 1/2 Z-SDM/1K-TA
Week 1 C/O 1/2 Z-SDM/1K-WO
2 C/O 2/2 Z-SDM/2K-WO
Signalling Devices
Function Voltage (V AC) Module Width Part Number
Buzzer 12 1 Z-SUM12
24 1 Z-SUM24
230 1 Z-SUM230
Bell 12 1 Z-GLO12
24 1 Z-GLO24
230 1 Z-GLO230
Transformers · 230 V AC
Description SecondaryVoltage (V)
SecondaryCurrent (A) Module Width Part Number
Bell (8 VA) 8 1 2 TR-G/8
4–8–12 1–1–0.67 2 TR-G3/8
8 1 2 TR-G/8-S *
Bell (18 VA) 4–8–12 2–2–1.5 2 TR-G3/18
12–24 2–1 3 TR-G2/24
Note * TR-G/8-S has primary switch.
20
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCB
Dis
trib
utio
n Bo
ards
· A
& B
Typ
e21
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCB
Dis
trib
utio
n Bo
ards
· A
& B
Typ
e
MCB Distribution BoardsControl and Switching DIN Mounted Devices
Fuse Basesmax rated current 32 A · for use with 10 x 38 gG (gL) fuses
Poles Part Number
1 SGI/1
1+N SGI/1N
2 SGI/2
3 SGI/3
3+N SGI/3N
Busbar Comb with Fork Connectors1 metre length
Description Poles Rating Part Number
Busbar block 1 63 A Z–GV–10/1P–1TE
3 63 A Z–GV–10/3P–3TE
1 80 A Z–GV–16/1P–1TE
3 80 A Z–GV–16/3P–3TE
End cover cap 2+3 63 A Z–AK–10/2+3P
2+3 80 A Z–AK–16/2+3P
20
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCB
Dis
trib
utio
n Bo
ards
· A
& B
Typ
e
21
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCB
Dis
trib
utio
n Bo
ards
· A
& B
Typ
e
MCB Distribution BoardsTechnical Data
A Type Distribution Boards
Electrical
Applicable standard BS EN 60439-3Busbar nominal rating 125 ABusbar short circuit withstand 16 kARated voltage 230 V AC 50/60 HzLimits of operation 40°C ambient 50% RHMaximum incomer rating 100 AMaximum outgoing device 63 A
Mechanical
Ingress protection IP40 with door closed, IP2X with door openEnclosure steel gauge 1.5 mmPaint finish RAL 7035 textured,epoxy powder coatedGland plate 1 blank and 1 with knockoutsMaximum cable capacity
Neutral bar 16 mm2
Earth bar 16 mm2
Main Earth termination 16 mm2
Incomers and outgoersRCBO 25 mm2
RCD 63 A 25 mm2
RCD 80 A / 100 A 50 mm2
MCB 25 mm2
Switch disconnectors 50 mm2
B Type Distribution Boards
Electrical
Applicable standard BS EN 60439-3Busbar nominal rating 250 ABusbar short circuit withstand 16 kA 1.2 sec / 22 kA 0.5 secRated voltage 415 V AC 50/60 HzLimits of operation 40°C ambient 50% RHMaximum incomer rating Internal device 125 A, external device 250 AMaximum outgoing device 63 A
Mechanical
Ingress protection IP40 with door closed, IP2X with door openEnclosure steel gauge 1.5 mmPaint finish RAL 7035 textured, epoxy powder coatedGland plate 1 blank and 1 with knockoutsMaximum cable capacity
Neutral bar 70 mm2
Earth bar 70 mm2
Main Earth termination 70 mm2
Incomers and outgoersRCBO 25 mm2
RCD 63A 25 mm2
RCD 80A/100A 50 mm2
MCB 25 mm2
Switch disconnectors – IS 50 mm2
MCCB/Switch disconnectors 120 mm2
22
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
i Pan
el B
oard
s23
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
i Pan
el B
oard
s
Mini Panel BoardsIntroduction
Mini Panel BoardsThe Mini Panel Board is a highly innovative new board featuring a pan assembly rated to 400 A. It offers a cost-effective and compact alternative to a traditional, assembled panel board, and is well suited to commercial and industrial applications.
As part of Moeller’s comprehensive range of consumer units, A & B Type boards and panel boards, the Mini Panel Board has been developed to meet the needs of UK specifi ers, electrical contractors and distributors to the latest British, European and international standards. In line with market requirements, the Mini Panel Board can incorporate energy metering.
Three Phase with 400 A BusbarNumber of
Outgoing WaysDimensions (mm)
Width Height Depth Part Number
4 610 960 200 FG-LH-04
8 610 960 200 FG-LH-08
12 610 1290 200 FG-LH-12
16 610 1290 200 FG-LH-16
Incomer Enclosuresupplied complete with shrouds and copper link
For Use With Dimensions (mm) Width Height Depth Part Number
LZMC3 or PN3 610 340 200 FG-LH/INC400
Incoming Devices · 3-Pole
Rated Current (A) Moulded CaseCircuit Breaker
SwitchDisconnector
160 LZMB2-A160 PN2-160
200 LZMB2-A200 PN2-200
250 LZMB2-A250 PN2-250
320 LZMN3-A320 PN3-400
400 LZMN3-A400 PN3-400
Note LZMN3 and PN3 must be used in conjunction with FG-LH/INC400 (below).
22
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
i Pan
el B
oard
s
23
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
i Pan
el B
oard
s
Mini Panel BoardsEnergy Metering
Energy Meters
Description Part Number
Multifunction energy meter KWH/A20
Multifunction energy meter, facility for harmonics measuring KWH/A40
Note Energy meters are enabled for the following add-on modules:A20 and A40: modbus 485 communication module, pulse output module;
A40: harmonics module, analogue module, profibus module, i/o module.Please contact your local sales engineer for the additional options.
Metering Section Enclosure
Description Dimensions (mm) Width Height Depth Part Number
Enclosure for up to 4 meters 610 460 180 FG-LH/MB
Cover plate for unused 96x96 meter cut-out FG-LH/MBP
Metering Connection Kits
Description Part Number
Wiring loom for CT, voltage and supply connections KWH/CBLB
DIN rail fuses for supply and voltage inputs, for 1 energy meter KWH/DINB
Earth common connection links for CTs, for 1 energy meter KWH/CTEB
Earth cable from CT to enclosure KWH/CTEARTH
Metering Kitcurrent transformers (see below) to be ordered separately
Description Part Number
Includes connection kits and KWH/A20 meter KWH/LHKIT
Metering Current Transformers
Description Part Number
Selected based on maximum full-load current to be measured CT-SET (***)
Note Add full-load current value in brackets (***).Please contact your local sales engineer for the options.
24
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
i Pan
el B
oard
s25
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
i Pan
el B
oard
s
Mini Panel BoardsOutgoing Devices
Miniature Circuit Breakers · 25 kAthermomagnetic release · switching capacity up to 25 kA at 415 V 50/60Hz
Poles Rated Current (A) B Curve C Curve D Curve
1-Pole
20 PLHT-B20 PLHT-C20 PLHT-D20
25 PLHT-B25 PLHT-C25 PLHT-D25
32 PLHT-B32 PLHT-C32 PLHT-D32
40 PLHT-B40 PLHT-C40 PLHT-D40
50 PLHT-B50 PLHT-C50 PLHT-D50
63 PLHT-B63 PLHT-C63 PLHT-D63
80 PLHT-B80 PLHT-C80 PLHT-D80
100 PLHT-B100 PLHT-C100 PLHT-D100
125 PLHT-B125 PLHT-C125 –
3-Pole
20 PLHT-B20/3 PLHT-C20/3 PLHT-D20/3
25 PLHT-B25/3 PLHT-C25/3 PLHT-D25/3
32 PLHT-B32/3 PLHT-C32/3 PLHT-D32/3
40 PLHT-B40/3 PLHT-C40/3 PLHT-D40/3
50 PLHT-B50/3 PLHT-C50/3 PLHT-D50/3
63 PLHT-B63/3 PLHT-C63/3 PLHT-D63/3
80 PLHT-B80/3 PLHT-C80/3 PLHT-D80/3
100 PLHT-B100/3 PLHT-C100/3 PLHT-D100/3
125 PLHT-B125/3 PLHT-C125/3 –
Toggle Colours
2 A 4 A 6 A 10 A 13 A 16 A
20 A 25 A 32 A 40 A 50 A 63 A
24
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
i Pan
el B
oard
s
25
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
i Pan
el B
oard
s
Terminal Extension Adapters
Description Part Number
35 mm2 (pack of 10) FG-KLA/ZB-35
50 mm2 (pack of 10) FG-KLA/ZB-50
Accessories · for FG-LH-*
Description Part Number
Lock and key FG-DOORLOCK
Busbar tag shroud FG-BTS
Blanking strips (6 modules) AP-45-W
Modular Service Box with 19" DIN railcomplete with Earth and Neutral terminal bars
Used on range Dimensions (mm) Width Height Depth Part Number
FG–LH–* Mini Panel Board 610 340 130 FG-LH/SM-30
Spreader Boxes (without door)
Used on range Dimensions (mm) Width Height Depth Part Number
FG–LH–* Mini Panel Board 610 340 130 FG-LH-EX
Glazed Door
Used on range Part Number
FG-LH-04,08 FG-LH-GD-4/8
FG-LH-12,16 FG-LH-GD-12/16
Cable Lugs · required as standard
Cable Size (mm2) For use with Number of Poles Description Part Number
95 LZMN2 / PN2 3 1 cable lug KS95-NZM7
120 LZMN2 / PN2 3 1 cable lug KS120-NZM7
150 LZMN2 / PN2 3 1 cable lug KS150-NZM7
185 LZMN2 / PN2 3 1 cable lug NZM2-XKS185
185 LZMN3 / PN3 3 1 cable lug NZM3-XKS185
240 LZMN3 / PN3 3 1 cable lug NZM3-XKS240
Note Order 3-off for 3-pole.Box Terminals · copper cable, stranded
For use with Number of Poles Terminal Capacity In (A) Part Number
LZMN2 / PN2 3 1 x (4–16) + 2 x (4–16) 160 NZM2-160-XKC
LZMN2 / PN2 3 1 x (25–185) + 2 x (25–70) 250 NZM2-250-XKC
LZMN3 / PN3 3 1 x (35–240) + 2 x (16–120) 500 NZM3-XKC
Mini Panel BoardsAccessories
26
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
i Pan
el B
oard
s27
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
i Pan
el B
oard
s
Installation Relays
Control Voltage Rated Current AC1 (A) Contacts Module Width Part Number
230 V AC 20 1 N/O 1 Z-RE230/S
20 2 N/O 1 Z-RE230/SS
20 1 N/O + 1 N/C 1 Z-RE230/SO
24 V AC 20 2 N/O 1 Z-RE24/SS
20 1 N/O + 1 N/C 1 Z-RE24/SO
24 V DC 20 2 N/O + 2 N/C 2 Z-RE23/2S20
Installation Contactors
Control Voltage Rated Current AC1 (A) Contacts Module Width Part Number
230 V AC 25 4 N/O 2 Z-SCH230/25-40
4 N/C 2 Z-SCH230/25-04
3 N/O + 1 N/C 2 Z-SCH230/25-31
2 N/O + 2 N/C 2 Z-SCH230/25-22
40 4 N/O 4 Z-SCH230/40-40
3 N/O + 1 N/C 4 Z-SCH230/40-31
2 N/O + 2 N/C 4 Z-SCH230/40-22
2 N/O 4 Z-SCH230/40-20
63 4 N/O 4 Z-SCH230/63-40
3 N/O + 1 N/C 4 Z-SCH230/63-31
2 N/O + 2 N/C 4 Z-SCH230/63-22
2 N/O 4 Z-SCH230/63-20
24 V AC 25 4 N/O 2 Z-SCH24/25-40
2 N/O + 2 N/C 2 Z-SCH24/25-22
Light Intensity Switch
Function Rated Current AC1 (A) Contacts Module Width Part Number
DIN rail mount 16 1 N/O 1 DS–GS/1S
DIN rail mount 16 1 C/O + Timer 3 DS–GS/1W
Outdoor installation 10 1 N/O – DS–GK
Spare Sensor for DS-DG – – – Z–DS/SENSOR
Cap for daylight 100–10,000 lux – – – Z–DS/KAPPE
Staircase Switch
Function Rated Current AC1 (A) Contacts Module Width Part Number
with stop function 16 1 C/O 1 TLE
stop & alarm function 16 1 C/O 1 TLK
Mini Panel BoardsControl and Switching Accessories
26
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
i Pan
el B
oard
s
27
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
i Pan
el B
oard
s
Analogue Time Switch
Drive Program Contacts Chan/Mod Part Number
Synchronous Day 1 N/O 1/1 Z-SGS/TA
Day 1 C/O 1/3 SU-GS/1W-TA
Week 1 C/O 1/3 SU-GS/1W-WO
Quartz Day 1 N/O 1/1 SU-CQ-TA
Day 1 C/O 1/3 SU-CQ/1W-A
Week 1 C/O 1/3 SU-CQ/1W-WO
Day + Week 2 C/O 2/6 SU-CQ/2W-TW
Digital Time Switch
Drive Program Contacts Chan/Mod Part Number
Quartz Day 1 C/O 1/2 Z-SDM/1K-TA
Week 1 C/O 1/2 Z-SDM/1K-WO
2 C/O 2/2 Z-SDM/2K-WO
Signalling Devices
Function Voltage (V AC) Module Width Part Number
Buzzer 12 1 Z-SUM12
24 1 Z-SUM24
230 1 Z-SUM230
Bell 12 1 Z-GLO12
24 1 Z-GLO24
230 1 Z-GLO230
Transformers · 230 V AC
Description SecondaryVoltage (V)
SecondaryCurrent (A) Module Width Part Number
Bell (8 VA) 8 1 2 TR-G/8
4–8–12 1–1–0.67 2 TR-G3/8
8 1 2 TR-G/8-S *
Bell (18 VA) 4–8–12 2–2–1.5 2 TR-G3/18
12–24 2–1 3 TR-G2/24
Note * TR-G/8-S has primary switch.
Busbar Comb with Fork Connectors1 metre length
Description Poles Rating (A) Part Number
Busbar block 1 63 Z–GV–10/1P–1TE
3 63 Z–GV–10/3P–3TE
1 80 Z–GV–16/1P–1TE
3 80 Z–GV–16/3P–3TE
End cover cap 2+3 63 Z–AK–10/2+3P
2+3 80 Z–AK–16/2+3P
Mini Panel BoardsControl and Switching Accessories
28
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
i Pan
el B
oard
s29
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
i Pan
el B
oard
s
Mini Panel Board · Three Phase with 400 A Busbar
General
Incoming options 3-Pole MCCB, 3-Pole Switch DisconnectorApplicable standard BS EN 60439-1: 1994
Electrical
Busbar nominal rating 400 ABusbar short-circuit withstand 40 kA for 0.5 s, 25 kA for 1 sRated voltage Ue 415 V AC 50/60 HzMaximum incomer rating 400 AMaximum outgoing device 125 ASafety class IElectromagnetic compatibility Environment 1Maximum amount of heat to be dissipated* * Calculated regarding IEC 890
FG-LH-04 148 WFG-LH-08 148 WFG-LH-12 123 WFG-LH-16 123 W
Mechanical
Ingress protection IP40 when the door is closed, IP30 when the door is open, IP2X without cover platePaint finish RAL 7035 textured, epoxy powder coatedLimits of operation 40°C ambient 50% RHEnclosure steel gauge 1.5 mmGland plate 1 blank and 1 with knockoutsMaximum cable capacity
Neutral bar 25 mm2 *Earth bar 25 mm2 *
* 35 mm2 with adaptor (FG-KLA/ZB-35), 50 mm2 with adaptor (FG-KLA/ZB-50)Main Earth termination 150 mm2
Main Neutral termination 150 mm2
Material
Plastic partsSupport for busbar Noryl SE1Cover for busbar PVC greyCover for neutral wire PVC transparentHinge roller PolyamideRotary lever lock Polyamide
Metal partsConsole for devices ST 37 1.00 mm galvanizedCasing ST 37 1.25 mmLid ST 37 1.25 mmDoor ST 37 1.25 mmMounting plate ST 37 1.5 mmBusbar copper E-Cu 58Neutral and Earth busbar MS 58Screws Galvanized and passivated
Environmental Conditions
Ambient temperature -5°C to +40°CAverage ambient temperature over 24 hours 35°CRelative air humidity 50% at 40°C
Mini Panel BoardsTechnical Data
28
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
i Pan
el B
oard
s
29
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
i Pan
el B
oard
s
Moulded Case Circuit Breakers · LZM
General
Standards IEC/EN 60947, VDE 0660Protection against direct contact Finger and back-of-hand proof to VDE 0160 part 100Climatic proofing Damp heat, constant, to IEC 60068-2-78, Damp heat, cyclic, to IEC 60068-2-30Ambient temperature -25°C / +70°CMechanical shock resistance 20 g (half-sinusoidal shock 20 ms)Safe isolation to VDE 0106 part 101 & 101/A1 Between auxiliary contacts and main circuits: 500 V AC
Between the auxiliary contacts: 300 V ACDirection of incoming supply As required
LZMB2-… LZMN3-…Rated impulse withstand voltage Main contacts Uimp (V) 8,000 8,000
Auxiliary contacts Uimp (V) 6,000 6,000Rated operational voltage Ue (V AC) 440 690Rated insulation voltage Ui (V) 690 690Overvoltage category / pollution degree III / 3 III / 3Terminal capacity mm2 1 x (25–185)
2 x (25–70)1 x (25–240)2 x (25–240)
Switching capacity
Rated short-circuit making capacity 240 V AC Icm (kA) 63 187400/415 V AC Icm (kA) 53 105
Rated short-circuit breaking capacity Icu to IEC/EN 60947 test cycle O-t-CO
240 V AC Icu (kA) 30 85400/415 V AC Icu (kA) 25 50
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO
240 V AC Ics (kA) 15 42.5400/415 V AC Ics (kA) 12.5 25
Utilisation category A A
Rated making and breaking capacity
Rated operational current AC-1 240 V AC Ie (A) 250 630400/415 V AC Ie (A) 250 630
Lifespan, mechanical(of which max. 20% trip by shunt/undervoltage release)
operations 20,000 15,000
Maximum operating frequency S/h 120 120Lifespan, electrical AC-1 240 V AC operations 10,000 5,000
400/415 V AC operations 7,500 3,000Current heat loss per pole at Iu W 19 40
Overload releases
Temperature compensation for PMC2 to IEC/EN 60947,VDE 0660, part 101. Residual error in range -25°C / +70°C (ref. temperature 40°C)
thermomagnetic %/K 0.3 –
electronic %/K 0.3 0.3
Total opening delay on short-circuit ms < 10 < 10
Mini Panel BoardsTechnical Data
30
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
i Pan
el B
oard
s31
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
B Pa
nel B
oard
s
Switch Disconnectors · PN
PN2-… PN3-…
Rated impulse withstand voltage Main contacts Uimp (V) 8,000 8,000Auxiliary contacts Uimp (V) 6,000 6,000
Rated operational voltage Ue (V AC) 525 525Overvoltage category / pollution degree III/3 III/3Terminal capacity mm2 1 x (25–185)
2 x (25–70)1 x (25–240)2 x (25–240)
Switching capacity
Rated short-circuit making capacity Icm (kA) 5.5 25
Rated short-time withstand currentt = 0.3s Icw (kA) 3.5 12t = 1s Icw (kA) 3.5 12
Rated conditional short-circuit current with back-up fuse A gG/gL 250 630240 V AC kA 100 100400/415 V AC kA 100 100
Rated making and breaking capacity
Rated operational current AC-22/23A240 V AC Ie (A) 250 630400/415 V AC Ie (A) 250 630
Lifespan, mechanical operations 10,000 7,500Maximum operating frequency S/h 30 30Lifespan, electrical AC-1 240 V AC operations 5,000 2,500
400/415 V AC operations 5,000 2,500Current heat loss per pole at Iu W 16 40
Miniature Circuit Breakers · PLHT
Electrical
Design according to EN 60947-2Current test marks as printed onto the deviceRated voltage
AC 230/400 VDC 60 V (per pole)
Ultimate short-circuit breaking capacity according to IEC/EN 60947-2Characteristics B, C In = 20–63 A 25 kA
In = 80–100 A 20 kAIn = 125 A 15 kA
Characteristic D In = 63 A 25 kAIn = 80 A 20 kAIn = 100 A 15 kA
Characteristic in accordance with characteristics B, C, DBack-up fuse max. 200 A gLRated insulation voltage 440 VPeak withstand voltage Uimp 4 kVSelectivity class in accordance with Class 3Endurance ≥ 20,000 operating cycles
Mechanical
Frame size 45 mmDevice height 90 mmDevice width 27 mm (1.5 MU) per poleMounting quick fastening with two lock-in positions on DIN rail EN 50022Degree of protection, built-in IP40Upper and lower terminals lift terminalsTerminal protection finger and hand touch safe, BGV A3, ÖVE-EN 6Terminal capacity 2.5–50 mm2
Mini Panel BoardsTechnical Data
30
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
i Pan
el B
oard
s
31
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
B Pa
nel B
oard
s
MCCB Panel BoardsIntroduction
MCCB Panel BoardsMoeller’s MCCB Panel Boards are designed and built to the latest British and European standards. The panel boards are ASTA certifi ed and fully type tested to BS EN 60439-1.
Wall-mounted with Form 2 separation as standard (Form 3b with additional shrouding), they provide a fl exible solution for a wide range of distribution requirements up to 800 A.
As well as Moeller’s LZM range of moulded case circuit breakers and PN / N switch disconnectors, the panel boards can also hold Moeller’s NZM range of moulded case circuit breakers to provide diagnostic and operational data. The NZM range can give information on energy use around a building and is also ideal for diagnostics in high integrity applications.
Panel Boards for 3-Pole IncomerNumber of
Outgoing Ways Rating (A) Dimensions (mm) Width Height Depth Part Number
6 400 900 1285 300 PB06/400
12 400 900 1600 300 PB12/400
6 630 900 1285 300 PB06/630
12 630 900 1600 300 PB12/630
6 800 900 1285 300 PB06/800
12 800 900 1600 300 PB12/800
Panel Boards for 4-Pole IncomerNumber of
Outgoing Ways Rating (A) Dimensions (mm) Width Height Depth Part Number
6 400 900 1285 300 PB06/400-4
12 400 900 1600 300 PB12/400-4
6 630 900 1285 300 PB06/630-4
12 630 900 1600 300 PB12/630-4
6 800 900 1285 300 PB06/800-4
12 800 900 1600 300 PB12/800-4
Note See page 38 for dimensions and technical data.
32
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
B Pa
nel B
oard
s33
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
B Pa
nel B
oard
s
MCCB Panel BoardsAdapter Kits · Incoming Devices
4-Pole Adapter Kit
Description Used with Part Number
Kit for 3-pole panel board to 4-polefor switched Neutral incomer All 3-pole panel boards PB4P-NLNK
Neutral Rail
Description Used with Part Number
Additional Neutral rail for outgoing devices All 3- & 4-pole panel boards PBNL-NSET
Moulded Case Circuit Breakersthermal-magnetic release · switching capacity 50 kA at 415 V 50/60 Hz
Number of Poles Rated Current In (A) Overload Release Ir (A) Short-circuit Release
Non-delayed Ir (A) Part Number
3 250 200–250 500–2750 LZMN3-A250
400 320–400 800–4400 LZMN3-A400
630 500–630 1260–5040 LZMN3-A630
800 400–800 1600–9600 LZMN4-A800
4 400 320–400 800–4400 LZMN3-4-A400
630 500–630 1260–5040 LZMN3-4-A630
800 400–800 1600–9600 LZMN4-4-A800
Notes For LZM, PN / N and NZM: Three switch positions I, +, 0; can be tripped remotely with shunt/undervoltage release (see page 35).Bolt terminals as standard – optional box terminals on page 34.
Switch Disconnectors
Number of Poles Rated Current In (A) Short-circuit ReleaseNon-delayed Ir (A) Part Number
3 400 630 PN3-400
630 630 PN3-630
800 2 x 800 N4-800
4 400 630 PN3-4-400
630 630 PN3-4-630
800 2 x 800 N4-4-800
Incoming Devices
32
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
B Pa
nel B
oard
s
33
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
B Pa
nel B
oard
s
Moulded Case Circuit Breakersthermal-magnetic release · 3-pole · Switching capacity 25 kA at 415 V 50/60 Hz
Rated Current In (A) Overload Release Ir (A) Short-circuit ReleaseNon-delayed Ir (A) Part Number
20 15–20 350 LZMB2-A20
25 20–25 350 LZMB2-A25
32 25–32 350 LZMB2-A32
40 32–40 320–400 LZMB2-A40
50 40–50 300–500 LZMB2-A50
63 50–63 380–630 LZMB2-A63
80 63–80 480–800 LZMB2-A80
100 80–100 600–1000 LZMB2-A100
125 100–125 750–1250 LZMB2-A125
160 125–160 960–1600 LZMB2-A160
200 160–200 1200–2000 LZMB2-A200
250 200–250 1500–2500 LZMB2-A250
Notes Three switch positions I, +, 0; can be tripped remotely with shunt/undervoltage release (see page 35).Order 3 x PBSP-BL below for each spare 3-pole outgoing way.
MCCB Panel BoardsOutgoing Devices
Outgoing Devices
Single-Pole Miniature Circuit Breakersthermomagnetic release · C curve · switching capacity up to 25 kA at 415V 50/60Hz
Rated currentIn (A)
Rated ultimate short circuitbreaking capacity Icu (kA)
PartNumber
20 25 PLHT-C20
25 25 PLHT-C25
32 25 PLHT-C32
40 25 PLHT-C40
50 25 PLHT-C50
63 25 PLHT-C63
80 20 PLHT-C80
100 20 PLHT-C100
125 15 PLHT-C125
Note Order PBPLHT-ADP on page 34 to install single pole outgoing ways in panel board.
34
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
B Pa
nel B
oard
s35
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
B Pa
nel B
oard
s
To achieve Form 3b separation, covers and terminal covers (two tables below) must be used.
Coversprovide degree of protection IP4X when using cable lugs
For use with Poles Part Number
LZM2 / PN2 / NZM2 3 NZM2-XKSA
LZM3 / PN3 / NZM3 3 NZM3-XKSA
LZM3 / PN3 / NZM3 4 NZM3-4-XKSA
LZM4 / N4 / NZM4 3 NZM4-XKSA
LZM4 / N4 / NZM4 4 NZM4-4-XKSA
Terminal Coversfor above cover
For use with Poles Part Number
LZM2 / PN2 / NZM2 3 NZM2-XIPA
LZM3 / PN3 / NZM3 3 NZM3-XIPA
LZM3 / PN3 / NZM3 4 NZM3-4-XIPA
Note NZM*-XIPA can be used in conjunction with NZM*-XKSA for protection against direct contact with box terminals to IP2X.
MCCB Panel BoardsAccessories
Cable Lugs
Cable Size (mm2) For use with Poles Part Number
95 LZM2 / PN2 / NZM2 3 KS95-NZM7
120 LZM2 / PN2 / NZM2 3 KS120-NZM7
150 LZM2 / PN2 / NZM2 3 KS150-NZM7
185 LZM2 / PN2 / NZM2 3 NZM2-XKS185
185 LZM3 / PN3 / N4 / NZM3&4 3/4 NZM3-XKS185
240 LZM3 / PN3 / N4 / NZM3&4 3/4 NZM3-XKS240
Notes Order 3-off for 3-pole and 4-off for 4-pole.Can be used in conjunction with NZM*-XKSA.
Panel Board Accessories
Description Notes Part Number
Plinth Fits both PB06/*** and PB12/*** PBPL
Spreader box – short Fits both PB06/*** and PB12/*** PBSBS
Spreader box – long Fits both PB06/*** and PB12/***PBSBL can only be used when fitting two vertical cable ways PBSBL
Vertical cable ways – 6-way Order two if required on both sides. PBVCW6
Vertical cable ways – 12-way Order two if required on both sides PBVCW12
Side gland plate 2mm thick for pb06/*** (1 only)
Supplied as optional extra for side entry to panel board(Comes with 1.6mm blank side plates as standard) PBGP-06
Side gland plate 2mm thick for pb12/*** (1 only)
Supplied as optional extra for side entry to panel board(Comes with 1.6mm blank side plates as standard) PBGP-12
Lockable door handle with key PBLOCK
Toggle lever locking device (toggle switch interlock)
Lockable in Off position with up to three padlocks (hasp 4–8 mm)Can be used with LZM / PN / NZM 2 and 3 NZM2/3-XKAV
Single-pole blanking plate This item includes single-pole blank for dead front and tag shroud for busbarPlease order 3-off for each spare 3-pole outgoing way PBSP-BL
Single-pole plht adapter Single-pole adapter kit for 3-pole ways, enabling up to three PLHT MCBsto be fitted as outgoers PBPLHT-ADP
Lockable handle with keyPBLOCK
Toggle lever locking deviceNZM2/3-XKAV
34
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
B Pa
nel B
oard
s
35
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
B Pa
nel B
oard
s
Box Terminalscopper cable, stranded
For use with Poles Terminal Capacity In (A) Part Number
LZM2 / PN2 / NZM2 3 1 x (4–16) + 2 x (4–16) 160 NZM2-160-XKC
LZM2 / PN2 / NZM2 3 1 x (25–185) + 2 x (25–70) 250 NZM2-250-XKC
LZM3 / PN3 / NZM3 3 1 x (35–240) + 2 x (16–120) 500 NZM3-XKC
LZM3 / PN3 / NZM3 4 1 x (35–240) + 2 x (16–120) 500 NZM3-4-XKC
Notes Conversion kit for bolted terminals on LZM* / PN* / NZM* -2&3.Can be used in conjunction with NZM*-XIPK.Box Terminal Covers
protection against direct contact with box terminals IP2X
For use with Poles Part Number
LZM2 / PN2 / NZM2 3 NZM2-XIPK
LZM3 / PN3 / NZM3 3 NZM3-XIPK
LZM3 / PN3 / NZM3 4 NZM3-4-XIPK
MCCB Panel BoardsAccessories
Tunnel Terminalsincludes terminal covers NZM*-XKSA
For use with Poles Conductor Terminal Capacity In (A) Part Number
LZM2 / PN2 / NZM2 3 Copper cable solid 1 x 16 stranded 1 x (25–185) 250 NZM2-XKA
LZM3 / PN3 / NZM3 3 Copper cable stranded 1 x (25–185) 350 NZM3-XKA1
LZM3 / PN3 / NZM3 3 Copper cable stranded 1 x (50–240) 630 NZM3-XKA2
LZM3 / PN3 / NZM3 4 Aluminium cable solid 1 x 16 stranded 1 x (25–185) 350 NZM3-4-XKA1
LZM3 / PN3 / NZM3 4 Aluminium cable stranded 1 x (50–240) and 2 x (50–240) 630 NZM3-4-XKA2
Auxiliary Contactsstandard auxiliary contact, switching with the main contacts · used for indication and interlocking tasks
For use with Contacts Part Number
LZM* / PN* / N* / NZM* 1 N/O M22-K10
1 N/C M22-KO1
Undervoltage Releasenon-delayed tripping of the switch when the rated control voltage is removed · suitable for use in emergency-stop circuits
For use with Rated Control Voltage Us (V) Part Number
LZM / PN / NZM -2&3 208–240 V 50/60Hz NZM2/3-XU208-240AC
380–440 V 50/60Hz NZM2/3-XU380-440AC
LZM4 / N4 / NZM4 208–240 V 50/60Hz NZM4-XU208-240AC
380–440 V 50/60Hz NZM4-XU380-440AC
D1
D2
Shunt Releasenon-delayed tripping of the switch when the rated control voltage is applied · not suitable for use in emergency-stop circuits
For use with Rated Control Voltage Us (V) Part Number
LZM / PN / NZM -2&3 208–250 V 50/60Hz NZM2/3-XA208-250AC/DC
380–440 V 50/60Hz NZM2/3-XA380-440AC/DC
LZM4 / N4 / NZM4 208–250 V 50/60Hz NZM4-XA208-250AC/DC
380–440 V 50/60Hz NZM4-XA380-440AC/DC
C1
C2
36
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
B Pa
nel B
oard
s37
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
B Pa
nel B
oard
s
Moulded Case Circuit Breakers · NZMAs standard, these NZM MCCBs have a built-in LED to indicate when the load has reached 70%, 100% and 120% of the set thermal current. NZM-XPC-Soft can be used to access more detailed information held within the breaker.
Electronic release, switching capacity 50 kA at 415 V 50/60 Hz.
PolesRated Current = Rated Uninterrupted Current
In = Iu (A)
Setting Range
Part NumberOverload Releases Short-circuit ReleasesMain Poles
Ir (A)Neutral
Ir (A)Non-delayed
Ii (A)DelayedIsd (A)
3 100 50–100 1200 100–1000 NZMN2-VE100
3 160 80–160 1920 160–1600 NZMN2-VE160
3 250 125–250 3000 250–2500 NZMN2-VE250
3 250 125–250 500–2750 250–2500 NZMN3-VE250
3 400 200–400 800–4400 400–4000 NZMN3-VE400
3 630 315–630 1260–5040 472–4410 NZMN3-VE630
3 630 315–630 1260–7560 630–6300 NZMN4-VE630
3 800 400–800 1600–9600 800–8000 NZMN4-VE800
4 400 200–400 200–400 800–4400 400–4000 NZMN3-4-VE400
4 630 315–630 315–630 1260–5040 472–4410 NZMN3-4-VE630
4 800 400–800 400–800 1600–9600 800–8000 NZMN4-4-VE800
Data Management Interface (DMI) ModulesThe DMI can be used in conjunction with the NZM 2, 3 and 4 electronic circuit breakers to collect and communicate diagnostic and operational data, as well as currents, motor starter function, parameterisation and control of the circuit breaker. This information can also be accessed and transferred via Profibus (using an NZM-XDMI-DPV1).
Description Part Number
Data Management Interface (DMI) Module NZM-XDMI612
Diagnostic Software for communication-enabled NZM circuit breakersUsing a simple connection from any NZM 2, 3 and 4 electronic circuit breaker to a PC, the software displays: • Phase currents • Status data • Load warnings • Current trending • Diagnostic data • Event history (last ten events), even when the MCCB is de-energised. The software also configures the Data Management Interface (DMI).
Description Part Number
Diagnostics and parameterisation software NZM-XPC-KIT
Notes Only for use in combination with circuit breakers with electronic releases.Free demo software NZM-XPC-Soft Demo is available from www.moeller.net.
MCCB Panel BoardsDiagnostics and Metering
36
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
B Pa
nel B
oard
s
37
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
B Pa
nel B
oard
s
Residual Current ProtectionThe new Moeller relay/transducer combination covers operating currents from 1 A to 1,800 A. Fault currents are detected and processed by the relay from 30 mA to 5 A. The adjustable relay provides a pre-warn function which alerts before the set fault current is exceeded. The pre-warning allows preventative action to be taken to avoid shutdown of the supply. The current relay signals that the set fault current has been exceeded with a changeover contact. Depending on the application, the contact signal can be subsequently processed in the controls, as well as by the shunt or undervoltage release fitted to the circuit breaker, which initiates the trip. The relay and transducer can be combined with every moulded case circuit breaker and switch disconnector. The ring-type transducer can be placed at a suitable position on the cable run.
Description Part Number
Residual Current 30 mA PFR-003
Differential Relay 300 mA PFR-03
Differential Relay 0.03–5 A PFR-5
Transducers andMagnetic Screens
– Internal Diameter:
Transducer Magnetic Screen
21 mm PFR-W-20 –
30 mm PFR-W-30 –
35 mm PFR-W-35 PFR-WMA-35
70 mm PFR-W-70 PFR-WMA-70
105 mm PFR-W-105 PFR-WMA-105
140 mm PFR-W-140 PFR-WMA-140
210 mm PFR-W-210 PFR-WMA-210
Attachment Clip for DIN mount of PFR-WMA-35 to -210 PFR-WC
MCCB Panel BoardsDiagnostics and Metering
Metering Options
Description
For details of energy metering options on the panel board, please contact your local sales engineer.
38
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
B Pa
nel B
oard
s39
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
B Pa
nel B
oard
s
Moulded Case Circuit Breaker Panel Boards
General Comments
Construction Steel structureType 3 Phase, 4 WireForms of segregation Form 2 standard, Form 3b with additional shroudingIncoming options 3P MCCB / Isolator
4P MCCB / IsolatorIncoming device ratings 400 A, 630 A and 800 A LZM3 / PN3 / N4 / NZM3&4Outgoing device ratings 20–250 A LZM2 / NZM2 (three-pole)
20–125 A PLHT (single-pole )Applicable standards Type Tested according to BS EN 60439-1 (ASTA Certified)Degree of protection IP40
Electrical Data
Busbar nominal rating 800 ABusbar short circuit withstand Up to 35 kA for 1 sRated operational voltage (Ue) 415 V 50/60 HzRated insulation voltage (Ui) 690 V ACMaximum incomer rating 800 AMaximum outgoer rating 250 A
Mechanical
Paint finish RAL7035 Light Grey Semi-texturedEnclosure steel gauge 1.6 mm, 2.5 mm, 1.0 mm Enclosure, top and bottom gland plates, dead-frontMax. incoming cable capacity 1 x 240 mm2 or 2 x 120 mm2 For 400 A and 630 A LZM3 / PN3 / NZM3 devices
1 x 185 mm2 or 2 x 185 mm2 For 800 A LZM4 / N4 / NZM4 devicesMax. outgoing cable capacity 1 x 120 mm2 or 2 x 70 mm2 For 250 A LZM2 / NZM2 devices
1 x 50 mm2 For PLHT devicesNeutral connection cable capacity 120 mm2
Earth connection cable capacity 70 mm2
Main Earth bolt cable capacity 120 mm2
Dimensions width x height x depth (mm)
Weight (Kg)Empty Full*
For PB06/*** panel board 900 x 1285 x 230 92 113For PB12/*** panel board 900 x 1600 x 230 120 168For PBPL – standard plinth 900 x 300 x 230For PBSBS – spreader box short 900 x 300 x 230For PBSBL – spreader box long 1500 x 300 x 230For PBVCW6 – vertical cable way for PB06/*** 300 x 1285 x 230For PBVCW12 – vertical cable way for PB12/*** 300 x 1600 x 230
* These weights are indications only and depend on number of breakers fitted
MCCB Panel BoardsTechnical Data
38
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
B Pa
nel B
oard
s
39
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
B Pa
nel B
oard
s
Moulded Case Circuit Breakers · LZM and NZM
General
Standards IEC/EN 60947, VDE 0660Protection against direct contact Finger and back-of-hand proof to VDE 0160 part 100Climatic proofing Damp heat, constant, to IEC 60068-2-78 · Damp heat, cyclic, to IEC 60068-2-30Ambient temperature -25°C / +70°CMechanical shock resistance 20 g (half-sinusoidal shock 20 ms)Safe isolation to VDE 0106 part 101 & 101/A1 Between auxiliary contacts and main circuits: 500 V AC · Between the auxiliary contacts: 300 V ACMounting position Vertical and 90° in all directionsDirection of incoming supply As required
Device type by rated uninterrupted current250 A max.LZMB2-…
630 A max.LZMN3-…
800 A max.LZMN4-… NZMN2-… NZMN3-… NZMN4-…
Rated impulse withstand voltage Main contacts Uimp (V) 8,000 8,000 8,000 8,000 8,000 8,000Auxiliary contacts
Uimp (V) 6,000 6,000 6,000 6,000 6,000 6,000
Rated operational voltage Ue (V AC) 440 690 690 690 690 690Rated insulation voltage Ui (V) 690 690 1,000 1,000 1,000 1,000Overvoltage category / pollution degree III/3 III/3 III/3 III/3 III/3 III/3
Switching capacity
Rated short-circuit making capacity 240 V AC Icm (kA) 63 187 105 187 187 110400/415 V AC Icm (kA) 53 105 105 110 110 110
Rated short-circuit breaking capacity Icu to IEC/EN 60947 test cycle O-t-CO
240 V AC Icu (kA) 30 85 50 85 85 50400/415 V AC Icu (kA) 25 50 50 50 50 50
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO
240 V AC Ics (kA) 15 42.5 25 85 85 37400/415 V AC Ics (kA) 12.5 25 25 50 50 37
Utilisation category A A B A A B
Rated making and breaking capacity
Rated operational current AC-1 240 V AC Ie (A) 250 630 800 – – –400/415 V AC Ie (A) 250 630 800 250 630 1,600
Lifespan, mechanical(of which max. 20% trip by shunt/undervoltage release)
operations 20,000 15,000 5,000 (Note 1) (Note 1) (Note 1)
Maximum operating frequency S/h 30 30 30 120 60 60Lifespan, electrical AC-1 240 V AC operations 10,000 5,000 1,500 – – –
400/415 V AC operations 2,500 3,000 1,500 10,000 5,000 3,000Current heat loss per pole at Iu W 19 40 97 19 40 97
Overload releases
Temperature compensation for PMC2 to IEC/EN 60947, VDE 0660, part 101. Residual error in range -25°C / +70°C (ref. temperature 40°C)
thermomagnetic %/K 0.3 – – – – –electronic %/K 0.3 0.3 0.3 – – –
Total opening delay on short-circuit ms < 10 < 10 <25 <415 V<35 >415 V
< 10 < 10 <25 <415 V<35 >415 V
Note For additional technical information on the NZM range please refer to the main catalogue for industrial switchgear.
MCCB Panel BoardsTechnical Data
40
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
B Pa
nel B
oard
s41
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
B Pa
nel B
oard
s
Miniature Circuit Breaker · PLHT
Electrical
Design according to EN 60947-2Current test marks as printed onto the deviceRated voltageAC 230/400 VDC 60 V (per pole)Ultimate short-circuit breaking capacity according to IEC/EN 60947-2Characteristics B, C In = 20–63 A 25 kA
In = 80–100 A 20 kAIn = 125 A 15 kA
Characteristic D In = 63 A 25 kAIn = 80 A 20 kAIn = 100 A 15 kA
Characteristic in accordance with characteristics B, C, DBack-up fuse max. 200 A gLRated insulation voltage 440 VPeak withstand voltage Uimp 4 kVSelectivity class in accordance with class 3Endurance ≥ 20,000 operating cycles
Mechanical
Frame size 45 mmDevice height 90 mmDevice width 27 mm (1.5MU) per poleMounting quick fastening with two lock-in positions on DIN rail EN 50022Degree of protection, built-in IP40Upper and lower terminals lift terminalsTerminal protection finger and hand touch safe, BGV A3, ÖVE-EN 6Terminal capacity 2.5–50 mm2
Switch Disconnectors · PN and NDevice type by
rated uninterrupted current630 A max.PN3-…
800 A max.N4-…
Rated impulse withstandvoltage
Main contacts Uimp (V) 8,000 8,000Auxiliary contacts Uimp (V) 6,000 6,000
Rated operational voltage Ue (V AC) 525 525Overvoltage category / pollution degree III / 3 III / 3
Switching capacity
Rated short-circuit making capacity Icm (kA) 25 53Rated short-time withstand current t = 0.3 s Icw (kA) 12 25
t = 1 s Icw (kA) 12 25Rated conditional short-circuit current with back-up fuse A gG/gL 630 800
240 V AC kA 100 100400/415 V AC kA 100 100
Rated making and breaking capacityRated operational current AC-22/23A 240 V AC Ie (A) 630 800
400/415 V AC Ie (A) 630 800Lifespan, mechanical operations 7,500 5,000Maximum operating frequency S/h 30 30Lifespan, electrical AC-1 240 V AC operations 2,500 1,500
400/415 V AC operations 2,500 1,500Current heat loss per pole at Iu W 40 97
MCCB Panel BoardsTechnical Data
40
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
B Pa
nel B
oard
s
41
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
B Pa
nel B
oard
s
Vertical Cable Ways, Spreader Box and Plinth Combinations
Vertical Cable Waysfit either side of the 6 way
(PBVCW6) and 12 way (PBVCW12) Panel Board
Spreader Box – Short (PBSBS)fits either the top or bottom
of both the 6 way and 12 way Panel Board
Spreader Box – Long (PBSBL)fits either the top or bottom of
the Panel Board, extending across Vertical Cables Ways fitted each
side.
Plinth (PBPL)can be fitted to the bottom of
the Panel Board, enabling it to be floor standing.
Please note: the Panel Board will still need to be bolted to a wall
– it is not free standing.
MCCB Panel BoardsConfiguration Illustration
42
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osed
Sw
itch
Fus
es43
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osed
Sw
itch
Fus
es
Enclosed Switch FusesIntroduction
Enclosed Switch FusesMoeller’s range of enclosed switch fuses comes complete with fully-rated fuses. Fully rated to AC23 suitable for distribution and motor loads, according to BS EN 60947-3.
Enclosed Switch Fuses3-pole & Neutral · complete with fuses
AC23 415 VCurrent (A) Enclosure Size Dimensions (mm)
Width Height Depth Part Number
20 1 180 215 135 ENCSWF/20TPN
32 1 180 215 135 ENCSWF/32TPN
63 2 270 300 150 ENCSW/F63TPN
100 3 320 395 175 ENCSWF/100TPN
160 3 320 395 175 ENCSWF/160TPN
200 3 320 395 175 ENCSWF/200TPN
250 4 450 600 275 ENCSWF/250TPN
400 4 450 600 275 ENCSWF/400TPN
630 5 550 750 300 ENCSWF/630TPN
800 5 550 750 300 ENCSWF/800TPN
Note See technical details for fuse sizes fi tted in each switch fuse on page 44.
42
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osed
Sw
itch
Fus
es
43
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osed
Sw
itch
Fus
es
Extension Boxessuitable for enclosed switch fuses utilising the same Enclosure Size reference
Enclosure Size Dimensions (mm) Width Height Depth Part Number
3 320 275 175 ENCX/100/200
4 450 275 275 ENCX/250/400
5 550 275 300 ENCX/630/800
Shrouds for Outgoing Terminations · IP20set of 3
Description Enclosure Ref Size Used with switch Number of Poles Part Number
IP20 shroud · standard 1 & 2 32 A / 63 A N/A N/A
Set of 3 terminal shrouds 3 100 A / 160 A / 200 A 3 IP20TS/100/200
4 250 A / 400 A 3 IP20TS/250/400
5 630 A / 800 A 3 IP20TS/630/800
Auxiliary Contact Blocksseparately direct-mountable contact blocks for 32 A to 800 A enclosed switches
Rating Ith (A) Contact Type Part Number
10 1 N/O ENCAUX1NO
10 1 N/C ENCAUX1NC
Note Maximum number in any combination of N/O or N/C contact blocks is 4 per switch.
Enclosed Switch FusesAccessories
44
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osed
Sw
itch
Fus
es45
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osed
MCC
Bs
Enclosed Switch FusesTechnical Data
Technical Data
Electrical
Characteristics (to EN IEC 60947-3)Thermal Current Ith (40°C) 20 32 63 100 160 200 250 400 630 800BS88 Fuse Size A1 A1 A2-A3 A4 A3-A4 A3-A4 B1-B2 B1-B2-B3-B4 C1-C2 D1/4Rated Insulation voltage Ui (V) 800 750 750 750 750 800 750 800 1,000 1,000Rated impulse withstand voltage Uimp (kV) 8 8 8 8 8 8 8 8 12 12Rated operational currents Ie (A) Rated voltage 400 V AC
AC-22 A / AC-22 B 20/20 32/32 63/63 100/100 160/160 200/200 250/250 400/400 630/630 800/800AC-23 A / AC-23 B 20/20 32/32 63/63 100/100 160/160 200/200 250/250 400/400 630/630 800/800
Rated voltage 690 V AC
AC-22 A / AC-22 B 20/20 32/32 63/63 100/100(2) 160/160(2) 200/200(2) 250/250(2) 315/400 500/630 800/800AC-23 A / AC-23 B 20/20 32/32 63/63 100/100(2) 160/160(2) 200/200(2) 250/250(2) 250/315 315/400 630/630
Fuse protected short-circuit characteristics Protective short-circuit current (kA rms) 80 80 80 80 80 80 80 80 80 80 Fuse switch cut-off current (kA peak) 5.5 5.5 10 20 20 20 32.5 40 70 80Fuse selection (maximum fuse size) (see Note 1 below relating to fuses selected) Bussman Standard max NITD 20 NITD 20 BOA 63 CEO 100 DEO 160 DEO 200 ED 250 ED 400 FF 630 GF 800
Motor max NITD 20M32
NITD 20M32
BOA 63M80
CEO 100M125
CEO 100M160
DEO 100M200
DD 200M315
ED 400M500
Lawson Standard max NIT 20 NIT 20 TIS 63 TCP100 CTFP 160 CTFP 200 TKF 250 TMF 400 TTM 630 TLM 800Motor max NIT 20M32 NIT 20M32 TIS 63M80 CTFP
100M125CTCP
100M160CTCP
100M200TF
200M315TMF
400M500 GE Standard max NIT 20 NIT 20 TIS 63 TCP100 TCP 100 TCP 100 TKF 250 TMF 400 TTM 630 TLM 800
Motor max NIT 20M32 NIT 20M32 TIS 63M80 OCP 100M125
OCP 100M160
OCP 100M160
TF 200M315
TMF 400M500
Connection Minimum Cu cable section (mm2) 2.5 2.5 10 25 35 50 95 185 2 x 150 2 x 185 Maximum Cu cable section (mm2) 16 16 25 95 95 95 240 240 2 x 300 2 x 300 Minimum tightening torque (Nm) 2 2 6 9 9 9 20 20 40 40
Mechanical
Endurance: number of operating cycles 20,000 20,000 10,000 10,000 10,000 10,000 10,000 10,000 8,000 5,000
Notes 1 Please ensure that the cut-off current of the fuse links does not exceed the value given for the fuse switch.2 Achieved by ensuring the terminal shrouds or screens are used.
• According to BS EN 60947-3• IP54 rated mild steel enclosures 20–32 A• IP55 rated mild steel enclosures 63–800 A• Hinged doors with fastening screws
• Paint finish RAL 7035• All switches are supplied complete with fuses• Disconnectable solid neutral link• Fully rated AC23 suitable for distribution and motor loads
• Door interlocked padlockable handle as standard• Incoming terminals IP20• Metric knockouts top and bottom (20–63 A)• Removable gland plates top and bottom (100–800 A)
Enclosed Switch Fuses
44
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osed
Sw
itch
Fus
es
45
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osed
MCC
Bs
Enclosed MCCBs
Enclosed MCCBsA range of enclosed moulded case circuit breakers, manufactured and designed to the latest UK and European standards, specifi cally for the contracting market.
Enclosed MCCBs · 3-PoleAC23 415 VCurrent (A)
Dimensions (mm) Width Height Depth MCCB Type Part Number
100 300 400 150 LZMB1 ENCCB/100/3
160 300 500 200 LZMB1 ENCCB/160/3
200 400 600 200 LZMB2 ENCCB/200/3
250 400 600 200 LZMN2 ENCCB/250/3
400 600 800 300 LZMN3 ENCCB/400/3
630 600 1000 300 LZMN3 ENCCB/630/3
800 600 1500 400 LZMN4 ENCCB/800/3
Incoming and Outgoing Terminal Shrouds3-pole · IP4X · top or bottom fi xing
For use with Part Number
LZM*1 NZM1-XKSA
LZM*2 NZM2-XKSA
LZM*3 NZM3-XKSA
LZM*4 NZM4-XKSA
Auxiliary Contacts
Description For use with Part Number
Internal fi xing N/O contact LZM M22-K10
Internal fi xing N/C contact LZM M22-K01
2 x early-make contacts LZM*1 NZM1-XHIV
2 x early-make contacts LZM*2/3 NZM2/3-XHIV
2 x early-make contacts LZM*4 NZM4-XHIV
Accessories for LZM MCCBsFor accessories available for LZM MCCBs please see Moulded Case Circuit Breaker section, page 65.
46
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osed
Sw
itch
Dis
conn
ecto
rs47
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osed
Sw
itch
Dis
conn
ecto
rs
Enclosed Switch Disconnectors
Enclosed Switch DisconnectorsMoeller’s range of enclosed switch disconnectors covers the range from 20 Amps through to 800 Amps. Designed and manufactured to meet UK and European standards.
All switches according to IEC EN 60947-3
Padlockable in Off position
IP55 metal enclosures
Sheet Steel Enclosures · Red/Yellow Handle · 3-PoleAC23 415 VCurrent (A)
Dimensions (mm) Width Height Depth Part Number
20 104 174 134 T0-2-1/ST/SVB
25 104 174 134 P1-25/ST/SVB
32 104 174 134 P1-32/ST/SVB
63 184 184 149 P3-63/ST/SVB
100 184 184 149 P3-100/ST/SVB
Sheet Steel Enclosures · Red/Yellow Handle · 6-Pole + 1 N/O + 1 N/CAC23 415 VCurrent (A)
Dimensions (mm) Width Height Depth Part Number
20 104 174 134 T0-4-15682/ST/SVB
32 184 284 149 T3-4-15682/ST/SVB
63 184 284 149 T5B-4-15164/ST/SVB
100 184 284 149 T5-4-151634/ST/SVB
Sheet Steel Enclosures · Black Handle · 3-Pole & NeutralAC23 415 VCurrent (A) Enclosure Size Dimensions (mm)
Width Height Depth Part Number
160 – 270 300 150 ENCSD/160TPN
200 – 270 300 150 ENCSD/200TPN
250 3 320 395 175 ENCSD/250TPN
400 4 450 600 175 ENCSD/400TPN
630 4 450 600 275 ENCSD/630TPN
800 5 450 750 300 ENCSD/800TPN
46
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osed
Sw
itch
Dis
conn
ecto
rs
47
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osed
Sw
itch
Dis
conn
ecto
rs
Enclosed Switch DisconnectorsAccessories
Extension Boxes for 250 A to 800 A Enclosuressuitable for enclosed fuse switches utilising the same Enclosure Size reference
Enclosure Size Dimensions (mm) Width Height Depth Part Number
3 320 275 175 ENCX/100/200
4 450 275 275 ENCX/250/400
5 550 275 375 ENCX/630/800
Shrouds for Outgoing Terminations · IP20
Description Number of Poles Enclosure Size Used with switch Part Number
set of 3 terminal shrouds IP20 3 – 100 A IP20TS/100
set of 3 terminal shrouds IP20 3 – 160 A / 200 A IP20TS/160/200
set of 3 terminal shrouds IP20 3 3 250 A IP20TS/200/250
set of 3 terminal shrouds IP20 3 4 400 A / 630 A IP20TS/400/630
set of 3 terminal shrouds IP20 3 5 800 A IP20TS/800
Auxiliary Contact Blocks
Description Max No of Contacts
Switch Rating (A)
Rating Ith (A) Contact Type Part Number
Pre-break auxiliary contact 2 160/200 5 CO– N/O N/C ENCAUX/2NO/2NC
1st on Pre-break auxiliary contact 1 250/800 16 CO– N/O N/C ENCAUX/1ST/1NO/1NC
2nd on Pre-break auxiliary contact 1 250/800 16 CO– N/O N/C ENCAUX/2ND/1NO/1NC
48
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osed
Sw
itch
Dis
conn
ecto
rs49
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osed
Sta
rter
s
Enclosed Switch DisconnectorsTechnical Data
Enclosed Switch Disconnectors• All switches according to IEC EN 60947-3• Padlockable in Off position• IP55 metal enclosures
Technical Data
Electrical
Characteristics (to EN IEC 60947-3)Thermal current Ith (40°C) 20 25 32 63 100 160 200 250 400 630 800Rated impulse withstand voltageUimp (kV)
6 6 6 6 6 8 8 8 12 12 12
Operational power at AC-23 (kW) Rated voltage 400 V AC 6.5 13 15 37 50 80 100 132 220 280 450 Rated voltage 690 V AC 6.5 11 18.5 30 45 55 75 90 150 150 185Fuse protected short-circuit rating A gG/gL 20 25 50 80 100 160 200 250 400 630 800Rated short-time withstand current 1s Icw Arms
320 640 640 1,260 2,000 7,000 9,000 9,000 13,000 13,000 26,000
Connection Minimum Cu cable section (mm2) 1 x
(1–2.5)1 x
(1.5–6)1 x
(1.5–6)1 x
(2.5–35)1 x
(2.5–35) 50 70 95 185 2 x 150 2 x 185
Maximum Cu cable section (mm2) 2 x (1–2.5)
2 x (1.5–6)
2 x (1.5–6)
2 x (2.5–10)
2 x (2.5–10) 95 95 150 240 2 x 300 2 x 300
Minimum tightening torque (Nm) 1 1.6 1.6 3 3 9 20 20 20 20 20
Mechanical
Endurance: number of operating cycles 1,000,000 300,000 300,000 100,000 100,000 10,000 10,000 10,000 5,000 5,000 3,000
48
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osed
Sw
itch
Dis
conn
ecto
rs
49
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osed
Sta
rter
s
Enclosed Starters
Enclosed StartersMoeller’s comprehensive range of enclosed starters has been designed to meet the specifi c needs of the UK market. Available in sheet steel IP55 enclosures in a variety of sizes, with and without isolators.
50
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osed
Sta
rter
s51
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osed
Sta
rter
s
Direct-On-Line without Isolator · 3-PoleAC3 400 V
kWDimensions (mm)
Width Height DepthOverload RelayType Required
Part Number(see Note 1 below)
4 104 174 134 ZB12-* XD4/ST
5.5 104 174 134 ZB12-* XD5,5/ST
7.5 104 174 134 ZB12-* XD7,5/ST
11 184 184 149 ZB32-* XD11/ST
15 184 184 149 ZB32-* XD15/ST
18.5 300 300 200 ZB65-* XD18,5/ST
22 300 300 200 ZB65-* XD22/ST
30 300 300 200 ZB65-* XD30/ST
Direct-On-Line Reversing without Isolator · 3-PoleAC3 400 V
kWDimensions (mm)
Width Height DepthOverload RelayType Required
Part Number(see Note 1 below)
4 184 184 149 ZB12-* XDR4/ST
5.5 184 184 149 ZB12-* XDR5,5/ST
Star-Delta without Isolator · 6-PoleAC3 400 V
kWDimensions (mm)
Width Height DepthOverload RelayType Required
Part Number(see Note 1 below)
5.5 284 184 149 ZB12-* XSD5,5/ST
7.5 284 184 149 ZB12-* XSD7,5/ST
11 284 184 149 ZB12-* XSD11/ST
15 284 184 149 ZB32-* XSD15/ST
22 300 300 200 ZB32-* XSD22/ST
30 300 300 200 ZB32-* XSD30/ST
37 300 300 200 ZB65-* XSD37/ST
45 300 300 200 ZB65-* XSD45/ST
55 300 400 200 ZB65-* XSD55/ST
75 400 500 200 ZB150-* XSD75/ST
90 400 500 200 ZB150-* XSD90/ST
Enclosed StartersStarters without Isolators
Notes1 Part Number must be completed with control voltage, either “(230V50HZ)” or “(400V50HZ)”, for example “XD4/ST(230V50HZ)”.2 ZB overload relays must be ordered separately.3 For star-delta starters, overload fitted directly below main or delta contactor, set relay to 0.58 x rated FLC.4 For all other voltages and versions available please contact technical support: details at bottom of each page.
50
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osed
Sta
rter
s
51
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osed
Sta
rter
s
Direct-On-Line with Isolator · 3-PoleAC3 400 V
kWDimensions (mm)
Width Height DepthOverload RelayType Required
Part Number(see Note 1 below)
4 184 184 149 ZB12-* XDP4/ST
5.5 184 184 149 ZB12-* XDP5,5/ST
7.5 184 184 149 ZB12-* XDP7,5/ST
11 184 184 149 ZB32-* XDP11/ST
15 184 184 149 ZB32-* XDP15/ST
18.5 300 300 200 ZB65-* XDP18,5/ST
22 300 300 200 ZB65-* XDP22/ST
30 300 300 200 ZB65-* XDP30/ST
Direct-On-Line Reversing with Isolator · 3-PoleAC3 400 V
kWDimensions (mm)
Width Height DepthOverload RelayType Required
Part Number(see Note 1 below)
4 284 184 149 ZB12-* XDRP4/ST
5.5 284 184 149 ZB12-* XDRP5,5/ST
Star-Delta with Isolator · 6-PoleAC3 400 V
kWDimensions (mm)
Width Height DepthOverload RelayType Required
Part Number(see Note 1 below)
5.5 284 184 149 ZB12-* XSDP5,5/ST
7.5 284 184 149 ZB12-* XSDP7,5/ST
11 284 184 149 ZB12-* XSDP11/ST
15 285 305 159 ZB32-* XSDP15/ST
22 400 400 200 ZB32-* XSDP22/ST
30 400 400 200 ZB32-* XSDP30/ST
37 400 400 200 ZB65-* XSDP37/ST
45 400 400 200 ZB65-* XSDP45/ST
55 400 400 200 ZB65-* XSDP55/ST
75 500 500 200 ZB150-* XSDP75/ST
90 500 500 200 ZB150-* XSDP90/ST
Enclosed StartersStarters with Isolators
Notes1 Part Number must be completed with control voltage, either “(230V50HZ)” or “(400V50HZ)”, for example “XDP4/ST(230V50HZ)”.2 ZB overload relays must be ordered separately.3 For star-delta starters, overload fitted directly below main or delta contactor, set relay to 0.58 x rated FLC.4 For all other voltages and versions available please contact technical support: details at bottom of each page.
52
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osed
Sta
rter
s53
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es
Overloads · for DOL and Star-Delta Starters
Motor Rating at AC-3 400 VOverload Range (A) Part NumberDOL kW Star-Delta kW
0.25 – 0.6 – 1 ZB12-1
0.37 – 1 – 1.6 ZB12-1,6
0.55 1.1 1 – 1.6 ZB12-1,6
0.75 1.5 1.6 – 2.4 ZB12-2,4
1.1 2.2 2.4 – 4 ZB12-4
1.5 3 2.4 – 4 ZB12-4
2.2 4 4 – 6 ZB12-6
3 5.5 6 – 10 ZB12-10
4 7.5 6 – 10 ZB12-10
5.5 – 9 – 12 ZB12-12
7.5 11 12 – 16 ZB12-16
11 15 16 – 24 ZB32-24
– 18.5 16 – 24 ZB32-24
– 22 16 – 24 ZB32-24
15 30 24 – 32 ZB32-32
18.5 37 24 – 40 ZB65-40
22 45 40 – 57 ZB65-57
30 – 40 – 57 ZB65-57
– 55 50 – 65 ZB65-65
– 75 70 – 100 ZB150-100
– 90 70 – 100 ZB150-100
– 110 95 – 125 ZB150-125
– 132 120 – 150 ZB150-150
Notes1 Always check motor rating plate for exact full-load current.2 ZB overload relays must be ordered separately.3 For star-delta starters, overload fitted directly below main or delta contactor, set relay to 0.58 x rated FLC.4 For all other voltages and versions available please contact technical support: details at bottom of each page.
Enclosed StartersStarter Overloads
52
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osed
Sta
rter
s
53
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es
EnclosuresIntroduction
EnclosuresIntroducing a range of insulated and metal enclosures, available in surface and fl ush mounted options. Usable ways on the insulated enclosures range from 4 through to 56, while the steel enclosures allow 2-row 48-way through to 6-row 196-ways, with paint fi nishes of white and grey and options that include clear doors. All the enclosures come complete with Neutral and Earth terminals.
54
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es55
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es
IP41 Surface-Mounted Moisture-Proof Compact Distribution Boxes
Neutral Terminals Earth Terminals Usable Ways Dimensions (mm) Width Height Depth Part Number
4 4 4 120 192 105 FKV-O7-FR41-1/4
7 7 8 192 192 105 FKV-O7-FR41-1/8
8 8 12 274 192 105 FKV-O7-FR41-1/12
10 10 12 274 259 138 FKV-O7-FR41-H-1/12
14 14 18 372 259 138 FKV-O7-FR41-H-1/18
17 17 24 274 384 138 FKV-O7-FR41-H-2/24
22 22 36 372 409 138 FKV-O7-FR41-H-2/36
28 28 54 372 559 138 FKV-O7-FR41-H-2/54
EnclosuresMoisture-Proof Compact Distribution Boxes
IP55 Surface-Mounted Moisture-Proof Compact Distribution Boxes
Neutral Terminals Earth Terminals Usable Ways Dimensions (mm) Width Height Depth Part Number
4 4 4 120 192 105 FKV-O7-FR55-1/4
7 7 8 192 192 105 FKV-O7-FR55-1/8
8 8 12 274 192 105 FKV-O7-FR55-1/12
10 10 12 274 259 138 FKV-O7-FR55-H-1/12
14 14 18 372 259 138 FKV-O7-FR55-H-1/18
17 17 24 274 384 138 FKV-O7-FR55-H-2/24
22 22 36 372 409 138 FKV-O7-FR55-H-2/36
28 28 54 372 559 138 FKV-O7-FR55-H-2/54
IP65 Surface-Mounted Moisture-Proof Compact Distribution Boxes
Neutral Terminals Earth Terminals Usable Ways Dimensions (mm) Width Height Depth Part Number
4 4 4 120 192 105 FKV-O7-FR65-1/4
7 7 8 192 192 105 FKV-O7-FR65-1/8
8 8 12 274 192 105 FKV-O7-FR65-1/12
10 10 12 274 259 138 FKV-O7-FR65-H-1/12
14 14 18 372 259 138 FKV-O7-FR65-H-1/18
17 17 24 274 384 138 FKV-O7-FR65-H-2/24
22 22 36 372 409 138 FKV-O7-FR65-H-2/36
28 28 54 372 559 138 FKV-O7-FR65-H-2/54
Accessories
Description Part Number
2 x 4 Neutral and protective Earth terminals FKV-O7-FR-N/PE-2X4
2 x 7 Neutral and protective Earth terminals FKV-O7-FR-N/PE-2X7
2 x 10 Neutral and protective Earth terminals FKV-O7-FR-N/PE-2X10
2 x 14 Neutral and protective Earth terminals FKV-O7-FR-N/PE-2X14
2 x 22 Neutral and protective Earth terminals FKV-O7-FR-N/PE-2X22
2 x 28 Neutral and protective Earth terminals FKV-O7-FR-N/PE-2X28
54
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es
55
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es
EnclosuresIP40 Compact Distribution Boxes
IP40 Compact Distribution Boxes · Flush-Mounted · Transparent Door
Neutral Terminals Earth Terminals Usable Ways
Dimensions (mm) Width Height
Surface Depth
Recess Depth Part Number
4 x 10 mm2 4 x 10 mm2 5 116 156 35 70 BC-U-1/5-ECO
8 x 10 mm2 8 x 10 mm2 8 195 195 35 70 BC-U-1/8-ECO
12 x 10 mm2 12 x 10 mm2 12 303 212 35 70 BC-U-1/12-ECO
18 x 10 mm2 18 x 10 mm2 18 410 260 35 71 BC-U-1/18-ECO
2 x (12 x 10 mm2) 2 x (12 x 10 mm2) 24 303 406 35 68 BC-U-2/24-ECO
2 x (18 x 10 mm2) 2 x (18 x 10 mm2) 36 330 522 36 64 BC-U-2/36-ECO
3 x (12 x 10 mm2) 3 x (12 x 10 mm2) 36 330 550 36 62 BC-U-3/36-ECO
IP40 Compact Distribution Boxes · Flush-Mounted · White Door
Neutral Terminals Earth Terminals Usable Ways
Dimensions (mm) Width Height
Surface Depth
Recess Depth Part Number
4 x 10 mm2 4 x 10 mm2 5 116 156 35 70 BC-U-1/5-TW-ECO
8 x 10 mm2 8 x 10 mm2 8 195 195 35 70 BC-U-1/8-TW-ECO
12 x 10 mm2 12 x 10 mm2 12 303 212 35 70 BC-U-1/12-TW-ECO
18 x 10 mm2 18 x 10 mm2 18 410 260 35 71 BC-U-1/18-TW-ECO
2 x (12 x 10 mm2) 2 x (12 x 10 mm2) 24 303 406 35 68 BC-U-2/24-TW-ECO
2 x (18 x 10 mm2) 2 x (18 x 10 mm2) 36 330 522 36 64 BC-U-2/36-TW-ECO
3 x (12 x 10 mm2) 3 x (12 x 10 mm2) 36 330 550 36 62 BC-U-3/36-TW-ECO
IP40 Compact Distribution Boxes · Surface-Mounted · Transparent Door
Neutral Terminals Earth Terminals Usable Ways Dimensions (mm) Width Height Depth Part Number
4 x 10 mm2 4 x 10 mm2 5 116 156 93 BC-O-1/5-ECO
8 x 10 mm2 8 x 10 mm2 8 195 195 90 BC-O-1/8-ECO
12 x 10 mm2 12 x 10 mm2 12 303 212 98 BC-O-1/12-ECO
18 x 10 mm2 18 x 10 mm2 18 410 260 98 BC-O-1/18-ECO
2 x (12 x 10 mm2) 2 x (12 x 10 mm2) 24 303 406 98 BC-O-2/24-ECO
2 x (18 x 10 mm2) 2 x (18 x 10 mm2) 36 410 522 98 BC-O-2/36-ECO
3 x (12 x 10 mm2) 3 x (12 x 10 mm2) 36 303 550 93 BC-O-3/36-ECO
3 x (18 x 10 mm2) 3 x (18 x 10 mm2) 54 410 784 98 BC-O-3/54-ECO
IP40 Compact Distribution Boxes · Surface-Mounted · White Door
Neutral Terminals Earth Terminals Usable Ways Dimensions (mm) Width Height Depth Part Number
4 x 10 mm2 4 x 10 mm2 5 116 156 93 BC-O-1/5-TW-ECO
8 x 10 mm2 8 x 10 mm2 8 195 195 90 BC-O-1/8-TW-ECO
12 x 10 mm2 12 x 10 mm2 12 303 212 98 BC-O-1/12-TW-ECO
18 x 10 mm2 18 x 10 mm2 18 410 260 98 BC-O-1/18-TW-ECO
2 x (12 x 10 mm2) 2 x (12 x 10 mm2) 48 303 406 98 BC-O-2/24-TW-ECO
2 x (18 x 10 mm2) 2 x (18 x 10 mm2) 72 410 522 98 BC-O-2/36-TW-ECO
3 x (12 x 10 mm2) 3 x (12 x 10 mm2) 108 303 550 93 BC-O-3/36-TW-ECO
3 x (18 x 10 mm2) 3 x (18 x 10 mm2) 162 410 784 98 BC-O-3/54-TW-ECO
56
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es57
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es
EnclosuresCompact Distribution Boxes
Accessories
Description Part Number
Combination-set BCZ-MP65-COMS
Mounting flange BCZ-MP65-MF
Lock-set BCZ-MP65-LS
Cable cover BCZ-MP65-CABC
Cover strip 6MU BCZ-MP65-COVS
Ventilation plug M20 BCZ-MP65-VP
Cable pull relief IP68 M20 BCZ-MP65-CPR-M20
Cable pull relief IP68 M25 BCZ-MP65-CPR-M25
Cable pull relief IP68 M32 BCZ-MP65-CPR-M32
IP65 Surface-Mounted Compact Distribution Boxes
Neutral Terminals Earth Terminals Usable Ways Dimensions (mm) Width Height Depth Part Number
1x16, 3x6 1x16, 3x6 3 100 150 96 BC-MP65-1/3
2x16, 3x6 2x16, 3x6 5 125 200 122 BC-MP65-1/5
2x16, 5x6 2x16, 5x6 9 200 200 122 BC-MP65-1/9
2x16, 10x6 2x16, 10x6 12 250 200 122 BC-MP65-1/12
1x25,4x16,12x6 1x25,4x16,12x6 24+4 300 450 142 BC-MP65-2/28
1x25,4x16,12x6 1x25,4x16,12x6 36+6 300 600 142 BC-MP65-3/42
1x25,6x16,18x6 1x25,6x16,18x6 48+8 300 750 142 BC-MP65-4/56
14 300 450 142 BC-MP65-2/14P
28 300 600 142 BC-MP65-3/28P
Compact Enclosure · IP30(no door or cover plate available)
Neutral Terminal Blocks Earth Terminal Blocks Usable Ways Dimensions (mm) Width Height Depth Part Number
– – 1+1 50 135 72 KLV-TC-2
– – 3+1 90 160 78 KLV-TC-4
– – 6+2 162 170 78 KLV-TC-8
4 – 3+1 90 160 78 KLV-TC-4-TB
4 – 6+2 162 170 78 KLV-TC-8-TB1
4 4 6+2 162 170 78 KLV-TC-8-TB2
Terminal Blocks · for KLV-TC Enclosures
Description Part Number
2 x 10 mm2 + 2 x 16 mm2 terminal block for use in KLV-TC-4 box KLV-TC-TB-4/4
2 x 10 mm2 + 2 x 16 mm2 terminal block for use in KLV-TC-8 box KLV-TC-TBC-4/4
2 x (2 x 10 mm2 + 2 x 16 mm2) terminal block for use in KLV-TC-8 box KLV-TC-TBC-4/4+4
56
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es
57
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es
Flat Distribution Boards · Surface-Mounted · Steel Door · Whiteincludes steel door, front plates, DIN rail frame and N-/PE-terminals
Module/Rows NeutralTerminals
EarthTerminals
UsableWays
Dimensions (mm) Width Height Depth Part Number
24/2 45 45 48 543 450 140 BF-O-2/48-UK
24/3 76 76 72 543 600 140 BF-O-3/72-UK
24/4 90 90 96 543 750 140 BF-O-4/96-UK
24/5 120 120 120 543 900 140 BF-O-5/120-UK
24/6 136 136 144 543 1050 140 BF-O-6/144-UK
33/4 120 120 132 666.5 750 140 BF-O-4/132-UK
33/5 152 152 165 666.5 900 140 BF-O-5/165-UK
33/6 152 152 198 666.5 1050 140 BF-O-6/198-UK
Flat Distribution Boards · Surface-Mounted · Steel Door · Greyincludes steel door, front plates, DIN rail frame and N-/PE-terminals
Module/Rows NeutralTerminals
EarthTerminals
UsableWays
Dimensions (mm) Width Height Depth Part Number
24/2 45 45 48 543 450 140 BF-O-2/48-G-UK
24/3 76 76 72 543 600 140 BF-O-3/72-G-UK
24/4 90 90 96 543 750 140 BF-O-4/96-G-UK
24/5 120 120 120 543 900 140 BF-O-5/120-G-UK
24/6 136 136 144 543 1050 140 BF-O-6/144-G-UK
33/4 120 120 132 666.5 750 140 BF-O-4/132-G-UK
33/5 152 152 165 666.5 900 140 BF-O-5/165-G-UK
33/6 152 152 198 666.5 1050 140 BF-O-6/198-G-UK
Flat Distribution Boards · Surface-Mounted · Transparent Door · Whiteincludes transparent door, front plates, DIN rail frame and N-/PE-terminals
Module/Rows NeutralTerminals
EarthTerminals
UsableWays
Dimensions (mm) Width Height Depth Part Number
24/2 45 45 48 543 450 140 BF-OT-2/48-UK
24/3 76 76 72 543 600 140 BF-OT-3/72-UK
24/4 90 90 96 543 750 140 BF-OT-4/96-UK
24/5 120 120 120 543 900 140 BF-OT-5/120-UK
24/6 136 136 144 543 1050 140 BF-OT-6/144-UK
33/4 120 120 132 666.5 750 140 BF-OT-4/132-UK
33/5 152 152 165 666.5 900 140 BF-OT-5/165-UK
33/6 152 152 198 666.5 1050 140 BF-OT-6/198-UK
Flat Distribution Boards · Surface-Mounted · Transparent Door · Greyincludes transparent door, front plates, DIN rail frame and N-/PE-terminals
Module/Rows NeutralTerminals
EarthTerminals
UsableWays
Dimensions (mm) Width Height Depth Part Number
24/2 45 45 48 543 450 140 BF-OT-2/48-G-UK
24/3 76 76 72 543 600 140 BF-OT-3/72-G-UK
24/4 90 90 96 543 750 140 BF-OT-4/96-G-UK
24/5 120 120 120 543 900 140 BF-OT-5/120-G-UK
24/6 136 136 144 543 1050 140 BF-OT-6/144-G-UK
33/4 120 120 132 666.5 750 140 BF-OT-4/132-G-UK
33/5 152 152 165 666.5 900 140 BF-OT-5/165-G-UK
33/6 152 152 198 666.5 1050 140 BF-OT-6/198-G-UK
Enclosures Flat Distribution Boards · Surface-Mounted
58
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es59
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es
Flat Distribution Boards · Flush-Mounted · Transparent Door · Whiteincludes transparent door, front plates, DIN rail frame and N-/PE-terminals
Module/Rows NeutralTerminals
EarthTerminals
UsableWays
Dimensions (mm) Width Height Depth Part Number
24/2 45 45 48 588 470 136 BF-UT-2/48-UK
24/3 76 76 72 588 620 136 BF-UT-3/72-UK
24/4 90 90 96 588 770 136 BF-UT-4/96-UK
24/5 120 120 120 588 920 136 BF-UT-5/120-UK
24/6 136 136 144 588 1070 136 BF-UT-6/144-UK
33/4 120 120 132 750 770 136 BF-UT-4/132-UK
33/5 152 152 165 750 920 136 BF-UT-5/165-UK
33/6 152 152 198 750 1070 136 BF-UT-6/198-UK
Flat Distribution Boards · Flush-Mounted · Transparent Door · Greyincludes transparent door, front plates, DIN rail frame and N-/PE-terminals
Module/Rows NeutralTerminals
EarthTerminals
UsableWays
Dimensions (mm) Width Height Depth Part Number
24/2 45 45 48 588 470 136 BF-UT-2/48-G-UK
24/3 76 76 72 588 620 136 BF-UT-3/72-G-UK
24/4 90 90 96 588 770 136 BF-UT-4/96-G-UK
24/5 120 120 120 588 920 136 BF-UT-5/120-G-UK
24/6 136 136 144 588 1070 136 BF-UT-6/144-G-UK
33/4 120 120 132 750 770 136 BF-UT-4/132-G-UK
33/5 152 152 165 750 920 136 BF-UT-5/165-G-UK
33/6 152 152 198 750 1070 136 BF-UT-6/198-G-UK
Flat Distribution Boards · Flush-Mounted · Steel Door · Whiteincludes steel door, front plates, DIN rail frame and N-/PE-terminals
Module/Rows NeutralTerminals
EarthTerminals
UsableWays
Dimensions (mm) Width Height Depth Part Number
24/2 45 45 48 588 470 136 BF-U-2/48-UK
24/3 76 76 72 588 620 136 BF-U-3/72-UK
24/4 90 90 96 588 770 136 BF-U-4/96-UK
24/5 120 120 120 588 920 136 BF-U-5/120-UK
24/6 136 136 144 588 1070 136 BF-U-6/144-UK
33/4 120 120 132 750 770 136 BF-U-4/132-UK
33/5 152 152 165 750 920 136 BF-U-5/165-UK
33/6 152 152 198 750 1070 136 BF-U-6/198-UK
Flat Distribution Boards · Flush-Mounted · Steel Door · Greyincludes steel door, front plates, DIN rail frame and N-/PE-terminals
Module/Rows NeutralTerminals
EarthTerminals
UsableWays
Dimensions (mm) Width Height Depth Part Number
24/2 45 45 48 588 470 136 BF-U-2/48-G-UK
24/3 76 76 72 588 620 136 BF-U-3/72-G-UK
24/4 90 90 96 588 770 136 BF-U-4/96-G-UK
24/5 120 120 120 588 920 136 BF-U-5/120-G-UK
24/6 136 136 144 588 1070 136 BF-U-6/144-G-UK
33/4 120 120 132 750 770 136 BF-U-4/132-G-UK
33/5 152 152 165 750 920 136 BF-U-5/165-G-UK
33/6 152 152 198 750 1070 136 BF-U-6/198-G-UK
EnclosuresFlat Distribution Boards · Flush-Mounted
58
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es
59
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es
Front Plates · Blind · White
Description Module/Rows Part Number
Infill blind front plate 24/0 BFZ-FP-0+/BL
Mid section single row plate 24/1 BFZ-FP-1/BL
Incoming/outgoing single row plate 24/1+ BFZ-FP-1+/BL
Mid section single row plate 33/1 BFZ-FP-1/BL3
Incoming/outgoing single row plate 33/1+ BFZ-FP-1+/BL3
Front Plates · Blind · Grey
Description Module/Rows Part Number
Infill blind front plate 24/0 BFZ-FP-0+/BL-G
Mid section single row plate 24/1 BFZ-FP-1/BL-G
Incoming/outgoing single row plate 24/1+ BFZ-FP-1+/BL-G
Mid section single row plate 33/1 BFZ-FP-1/BL3-G
Incoming/outgoing single row plate 33/1+ BFZ-FP-1+/BL3-G
Front Plates · 45 mm Device Cut-out · White
Description Module/Rows Part Number
Mid section single row plate 24/1 BFZ-FP-1/24
Incoming/outgoing single row plate 24/1+ BFZ-FP-1+/24
Mid section single row plate 33/1 BFZ-FP-1/33
Incoming/outgoing single row plate 33/1+ BFZ-FP-1+/33
Front Plates · 45 mm Device Cut-out · Grey
Description Module/Rows Part Number
Mid section single row plate 24/1 BFZ-FP-1/24-G
Incoming/outgoing single row plate 24/1+ BFZ-FP-1+/24-G
Mid section single row plate 33/1 BFZ-FP-1/33-G
Incoming/outgoing single row plate 33/1+ BFZ-FP-1+/33-G
DIN Rail Frame Replacement
Description Module/Rows Part Number
Two row DIN rail frame 24/2 BFZ-DINS-2/48
Three row DIN rail frame 24/3 BFZ-DINS-3/72
Four row DIN rail frame 24/4 BFZ-DINS-4/96
Five row DIN rail frame 24/5 BFZ-DINS-5/120
Six row DIN rail frame 24/6 BFZ-DINS-6/144
Four row DIN rail frame 33/4 BFZ-DINS-4/132
Five row DIN rail frame 33/5 BFZ-DINS-5/165
Six row DIN rail frame 33/6 BFZ-DINS-6/198
EnclosuresFlat Distribution Boards · Accessories
60
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es61
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es
Universal Mounting Plate
Description Module/Rows Part Number
Mounting plate for surface-mounted enclosures 24/1+ BFZ-O-ITMPL-1+/24
Mounting plate for flush-mounted enclosures 24/1+ BFZ-U-ITMPL-1+/24
Mounting plate for surface-mounted enclosures 33/1+ BFZ-O-ITMPL-1+/33
Mounting plate for flush-mounted enclosures 33/1+ BFZ-U-ITMPL-1+/33
Fastening Clip for Universal Mounting Platefor mounting components
Description Number
Part number is for 1 clip; sold in bags of 10 BFZ-MPFC
MCCB Fitting Set · for LZMB1includes plate and base
Colour Module/Rows Part Number
white 24/1+ BFZ-NZM1-SET
grey 24/1+ BFZ-NZM1-SET-G
white 33/1+ BFZ-NZM1-SET/33
grey 33/1+ BFZ-NZM1-SET/33-G
Internal Section Separation Plate
Colour Module/Rows Part Number
white 24/0 BFZ-SP-24
grey 24/0 BFZ-SP-24-G
white 33/0 BFZ-SP-33
grey 33/0 BFZ-SP-33-G
Wire Fixing Rail
Description Module/Rows Part Number
Wire fixing rail for 24-module enclosure 24/0 BFZ-WFR-24
Wire fixing rail for 33-module enclosure 33/0 BFZ-WFR-33
Lock Set
Description Part Number
Lock set for all enclosures KLV-U-SS-F/SF
EnclosuresFlat Distribution Boards · Accessories
60
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es
61
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es
Terminal Block Sets · 63 Afor Neutral or Earth terminations
Description Part Number
2 x 25 mm2 + 9 x 16 mm2 BFZ-TS-KL11
2 x 25 mm2 + 13 x 16 mm2 BFZ-TS-KL15
2 x 25 mm2 + 27 x 16 mm2 BFZ-TS-KL29
2 x 25 mm2 + 43 x 16 mm2 BFZ-TS-KL45
2 x 25 mm2 + 58 x 16 mm2 BFZ-TS-KL60
2 x 25 mm2 + 74 x 16 mm2 BFZ-TS-KL76
Terminal Supports
Description Part Number
Horizontal support KT-3
Vertical support KT-5
Terminal Blocks only · 63 A
Description Part Number
1 x 25 mm2 + 3 x 16 mm2 KL4
1 x 25 mm2 + 6 x 16 mm2 KL7
2 x 25 mm2 + 9 x 16 mm2 KL11
2 x 25 mm2 + 13 x 16 mm2 KL15
2 x 25 mm2 + 23 x 16 mm2 KL25
2 x 25 mm2 + 27 x 16 mm2 KL29
2 x 25 mm2 + 43 x 16 mm2 KL45
2 x 25 mm2 + 58 x 16 mm2 KL60
2 x 25 mm2 + 74 x 16 mm2 KL76
Cable Extension Terminal
Description Part Number
Terminal for 35 mm2 cables KLA
Terminal Blocks
Description Part Number
1-Pole 80 A terminal block BPZ-KB-4/80
160 A terminal block BPZ-KB-6/160
250 A terminal block BPZ-KB-11/250
4-Pole 125 A, 1 x (L1/L2/L3/N), 7xL1 / 7xL2 / 7xL3 / 10xN BPZ-KB-8/125
160 A, 1 x (L1/L2/L3/N), 11xL1 / 11xL2 / 11xL3 / 11xN BPZ-KB-11/160
EnclosuresFlat Distribution Boards · Accessories
62
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es63
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es
Mounting Plate for Marking Strip
Description Part Number
For 24 modules per row BFZ-PE-432
EnclosuresFlat Distribution Boards · Accessories
Blanking Strips
Description Part Number
Blanking strips (10 x 0.5 modules) AM-45
Blanking strips (2 x 10 modules) AP-45
Blanking strips (6 modules) AP-45-W
Blanking strips – white (1 metre) NBP-1000-W
Earthing Set for Door
Description Part Number
Comprises cable with ring terminals, nuts and washers BFZ-DES
62
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es
63
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es
Surface-Mounted Moisture-Proof Compact Distribution BoxesFKV-07-FR (-H)
General
Good space for mounting and wiring componentsSpace for wiring behind the DIN rail FKV-07-FR: 10 mm · FKV-07-FR-H: 30 mmDistance between DIN rails 150 mm (except FKV-07-FR…-H-2/24: 125 mm)Mounting of terminal support above or below (from FKV-07-FR…-H-2/36 also height adjustment possible)Impact-resistant, fire-retardant plastic, whitePre-moulded PG-bushing on every sideDoor on the left or rightIP41, IP55 and IP65 availableAttractive modern design
Electrical
Design according to IEC 670Degree of protection IP41 to EN 60529 · IP55 to EN 60529 · IP65 to EN 60529Protection class IIRated voltage 400 V AC / 50HzFor network systems TN, TT and IT
Mechanical
Material:Surface mountingEnclosure IP41 and IP55 PS IP65 PCColour WhiteDoor PC colour WhiteDistance between DIN rails 150 mm Type FKV-O7-FR..-H-2/24 125 mmDevice support rail DIN rail 35 x 7.5 mm
Surface-Mounted and Flush-Mounted Compact Distribution BoxesBC-O-…(-TW)-ECO / BC-U-…(-TW)-ECO
General
Range of enclosure, flush- and surface-mountedChoice of transparent door or white doorIncludes device support railComplete with Neutral and earth terminalsFrom 1-row/5-module up to 3-row/54-module
Electrical
Design according to IEC 439-1, -3Degree of protection IP40Protection class IIRated voltage 400 V AC / 50HzFor network systems TN, TT, IT
Mechanical
Material ABSColour / White RAL 9003Temperature resistance -20°C to +70°C
EnclosuresTechnical Data
64
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es65
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
EnclosuresTechnical Data
Surface-Mounted Moisture-Proof Compact Distribution BoxesBC-MP65
General
Moisture-proof compact distribution box with 3, 5, 9, 12, 24+4, 36+6 and 48+8 module unitsImpact-resistant and flame-retardant plasticEach hinged cover is lockable, sealable and removable
Electrical
Degree of protection IP55, IP65Protection class IIRated voltage 400 V AC / 50 Hz
Mechanical
Material Polystyrene (Basic material is halogen-free; only the marginal added flame-retardant consists of up to 6% particles of halogen.)
Burning behaviour acc. to EN60695/UL94 960°C/V-2Max. ambient temperature -25°C to +40°CColour similar to RAL 7035Distance between DIN rails 150 mmMetric cable entry points top and bottom
Flat Distribution Boards · Steel
General
Flat installation distribution board for surface-and flush-mounting2 to 6 rows with 24 module units per row4 to 6 rows with 33 module units per rowEnclosure Pre stamped cable entry openings at the bottom Terminals pre-mounted in the enclosure Easy removable knock-outs 127 mm depth Removable DIN rail frame 150 mm distance between DIN rails MCCB can be mounted internally to be used as incomer
Electrical
Design according to EN 60439-1,-3 · EN 62208Degree of protection IP30 according to EN 60529Protection class I Rated voltage AC 240/415 V 50/60 Hz
Mechanical
Enclosure Steel sheet · Polyester powder coatedDoor Steel sheet · Polyester powder coatedFront plates Steel sheet · Polyester powder coatedDIN rail frame Steel sheet galvanisedColour white RAL 9016 / grey RAL 7035Distance between DIN rails 150 mm
64
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Encl
osur
es
65
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
Miniature Circuit BreakersIntroduction
Miniature Circuit Breakers (MCBs)Moeller’s range of miniature circuit breakers has been designed to meet UK, European and international standards. With ratings from 0.16 Amps through to 125 Amps and fault levels up to 25 kA, Moeller’s comprehensive range can satisfy the requirements of all installations.
66
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)67
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
Miniature Circuit Breakers6 kA range · Single-Pole
Miniature Circuit Breakers · Single-Pole6 kA · EN 60898
Rated Current In (A) B Curve C Curve D Curve
0.16 – PLS6-C0.16 –
0.25 – PLS6-C0.25 –
0.5 – PLS6-C0.5 –
0.75 – PLS6-C0.75 –
1 PLS6-B1 PLS6-C1 PLS6-D1
1.5 PLS6-B1.5 PLS6-C1.5 PLS6-D1.5
1.6 PLS6-B1.6 PLS6-C1.6 PLS6-D1.6
2 PLS6-B2 PLS6-C2 PLS6-D2
2.5 PLS6-B2.5 PLS6-C2.5 PLS6-D2.5
3 PLS6-B3 PLS6-C3 PLS6-D3
3.5 PLS6-B3.5 PLS6-C3.5 PLS6-D3.5
4 PLS6-B4 PLS6-C4 PLS6-D4
5 PLS6-B5 PLS6-C5 PLS6-D5
6 PLS6-B6 PLS6-C6 PLS6-D6
8 PLS6-B8 PLS6-C8 PLS6-D8
10 PLS6-B10 PLS6-C10 PLS6-D10
12 PLS6-B12 PLS6-C12 PLS6-D12
13 PLS6-B13 PLS6-C13 PLS6-D13
15 PLS6-B15 PLS6-C15 PLS6-D15
16 PLS6-B16 PLS6-C16 PLS6-D16
20 PLS6-B20 PLS6-C20 PLS6-D20
25 PLS6-B25 PLS6-C25 PLS6-D25
32 PLS6-B32 PLS6-C32 PLS6-D32
40 PLS6-B40 PLS6-C40 PLS6-D40
50 PLS6-B50 PLS6-C50 PLS6-D50 *
63 PLS6-B63 PLS6-C63 PLS6-D63 *
Note * PLS6-D50 and -D63 available July 2007.
Toggle Colours
2 A 4 A 6 A 10 A 13 A 16 A
20 A 25 A 32 A 40 A 50 A 63 A
66
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
67
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
Miniature Circuit Breakers · Double-Pole6 kA · EN 60898
Rated Current In (A) B Curve C Curve D Curve
0.16 – PLS6-C0.16/2 –
0.25 – PLS6-C0.25/2 –
0.5 – PLS6-C0.5/2 PLS6-D0.5/2
0.75 – PLS6-C0.75/2 –
1 PLS6-B1/2 PLS6-C1/2 PLS6-D1/2
1.5 PLS6-B1.5/2 PLS6-C1.5/2 PLS6-D1.5/2
1.6 PLS6-B1.6/2 PLS6-C1.6/2 PLS6-D1.6/2
2 PLS6-B2/2 PLS6-C2/2 PLS6-D2/2
2.5 PLS6-B2.5/2 PLS6-C2.5/2 PLS6-D2.5/2
3 PLS6-B3/2 PLS6-C3/2 PLS6-D3/2
3.5 PLS6-B3.5/2 PLS6-C3.5/2 PLS6-D3.5/2
4 PLS6-B4/2 PLS6-C4/2 PLS6-D4/2
5 PLS6-B5/2 PLS6-C5/2 PLS6-D5/2
6 PLS6-B6/2 PLS6-C6/2 PLS6-D6/2
8 PLS6-B8/2 PLS6-C8/2 PLS6-D8/2
10 PLS6-B10/2 PLS6-C10/2 PLS6-D10/2
12 PLS6-B12/2 PLS6-C12/2 PLS6-D12/2
13 PLS6-B13/2 PLS6-C13/2 PLS6-D13/2
15 PLS6-B15/2 PLS6-C15/2 PLS6-D15/2
16 PLS6-B16/2 PLS6-C16/2 PLS6-D16/2
20 PLS6-B20/2 PLS6-C20/2 PLS6-D20/2
25 PLS6-B25/2 PLS6-C25/2 PLS6-D25/2
32 PLS6-B32/2 PLS6-C32/2 PLS6-D32/2
40 PLS6-B40/2 PLS6-C40/2 PLS6-D40/2
50 PLS6-B50/2 PLS6-C50/2 PLS6-D50/2 *
63 PLS6-B63/2 PLS6-C63/2 PLS6-D63/2 *
Note * PLS6-D50/2 and -D63/2 available July 2007.
Miniature Circuit Breakers6 kA range · Double-Pole
Toggle Colours
2 A 4 A 6 A 10 A 13 A 16 A
20 A 25 A 32 A 40 A 50 A 63 A
68
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)69
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
Miniature Circuit Breakers · Triple-Pole6 kA · EN 60898
Rated Current In (A) B Curve C Curve D Curve
0.16 – PLS6-C0.16/3 –
0.25 – PLS6-C0.25/3 –
0.5 – PLS6-C0.5/3 PLS6-D0.5/3
0.75 – PLS6-C0.75/3 –
1 PLS6-B1/3 PLS6-C1/3 PLS6-D1/3
1.5 PLS6-B1.5/3 PLS6-C1.5/3 PLS6-D1.5/3
1.6 PLS6-B1.6/3 PLS6-C1.6/3 PLS6-D1.6/3
2 PLS6-B2/3 PLS6-C2/3 PLS6-D2/3
2.5 PLS6-B2.5/3 PLS6-C2.5/3 PLS6-D2.5/3
3 PLS6-B3/3 PLS6-C3/3 PLS6-D3/3
3.5 PLS6-B3.5/3 PLS6-C3.5/3 PLS6-D3.5/3
4 PLS6-B4/3 PLS6-C4/3 PLS6-D4/3
5 PLS6-B5/3 PLS6-C5/3 PLS6-D5/3
6 PLS6-B6/3 PLS6-C6/3 PLS6-D6/3
8 PLS6-B8/3 PLS6-C8/3 PLS6-D8/3
10 PLS6-B10/3 PLS6-C10/3 PLS6-D10/3
12 PLS6-B12/3 PLS6-C12/3 PLS6-D12/3
13 PLS6-B13/3 PLS6-C13/3 PLS6-D13/3
15 PLS6-B15/3 PLS6-C15/3 PLS6-D15/3
16 PLS6-B16/3 PLS6-C16/3 PLS6-D16/3
20 PLS6-B20/3 PLS6-C20/3 PLS6-D20/3
25 PLS6-B25/3 PLS6-C25/3 PLS6-D25/3
32 PLS6-B32/3 PLS6-C32/3 PLS6-D32/3
40 PLS6-B40/3 PLS6-C40/3 PLS6-D40/3
50 PLS6-B50/3 PLS6-C50/3 PLS6-D50/3 *
63 PLS6-B63/3 PLS6-C63/3 PLS6-D63/3 *
Note * PLS6-D50/3 and -D63/3 available July 2007.
Miniature Circuit Breakers6 kA range · Triple-Pole
Toggle Colours
2 A 4 A 6 A 10 A 13 A 16 A
20 A 25 A 32 A 40 A 50 A 63 A
68
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
69
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
Miniature Circuit Breakers · Four-Pole6 kA · EN 60898
Rated Current In (A) B Curve C Curve D Curve
0.16 – PLS6-C0.16/4 –
0.25 – PLS6-C0.25/4 –
0.5 – PLS6-C0.5/4 PLS6-D0.5/4
0.75 – PLS6-C0.75/4 –
1 PLS6-B1/4 PLS6-C1/4 PLS6-D1/4
1.5 PLS6-B1.5/4 PLS6-C1.5/4 PLS6-D1.5/4
1.6 PLS6-B1.6/4 PLS6-C1.6/4 PLS6-D1.6/4
2 PLS6-B2/4 PLS6-C2/4 PLS6-D2/4
2.5 PLS6-B2.5/4 PLS6-C2.5/4 PLS6-D2.5/4
3 PLS6-B3/4 PLS6-C3/4 PLS6-D3/4
3.5 PLS6-B3.5/4 PLS6-C3.5/4 PLS6-D3.5/4
4 PLS6-B4/4 PLS6-C4/4 PLS6-D4/4
5 PLS6-B5/4 PLS6-C5/4 PLS6-D5/4
6 PLS6-B6/4 PLS6-C6/4 PLS6-D6/4
8 PLS6-B8/4 PLS6-C8/4 PLS6-D8/4
10 PLS6-B10/4 PLS6-C10/4 PLS6-D10/4
12 PLS6-B12/4 PLS6-C12/4 PLS6-D12/4
13 PLS6-B13/4 PLS6-C13/4 PLS6-D13/4
15 PLS6-B15/4 PLS6-C15/4 PLS6-D15/4
16 PLS6-B16/4 PLS6-C16/4 PLS6-D16/4
20 PLS6-B20/4 PLS6-C20/4 PLS6-D20/4
25 PLS6-B25/4 PLS6-C25/4 PLS6-D25/4
32 PLS6-B32/4 PLS6-C32/4 PLS6-D32/4
40 PLS6-B40/4 PLS6-C40/4 PLS6-D40/4
50 PLS6-B50/4 PLS6-C50/4 PLS6-D50/4 *
63 PLS6-B63/4 PLS6-C63/4 PLS6-D63/4 *
Note * PLS6-D50/4 and -D63/4 available July 2007.
Miniature Circuit Breakers6 kA range · Four-Pole
Toggle Colours
2 A 4 A 6 A 10 A 13 A 16 A
20 A 25 A 32 A 40 A 50 A 63 A
70
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)71
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
Miniature Circuit Breakers · Triple-Pole & Neutral6 kA · EN 60898
Rated Current In (A) B Curve C Curve D Curve
0.16 – PLS6-C0,16/3N –
0.25 – PLS6-C0.25/3N –
0.5 – PLS6-C0.5/3N PLS6-D0.5/3N
0.75 – PLS6-C0.75/3N –
1 PLS6-B1/3N PLS6-C1/3N PLS6-D1/3N
1.5 PLS6-B1.5/3N PLS6-C1.5/3N PLS6-D1.5/3N
1.6 PLS6-B1.6/3N PLS6-C1.6/3N PLS6-D1.6/3N
2 PLS6-B2/3N PLS6-C2/3N PLS6-D2/3N
2.5 PLS6-B2.5/3N PLS6-C2.5/3N PLS6-D2.5/3N
3 PLS6-B3/3N PLS6-C3/3N PLS6-D3/3N
3.5 PLS6-B3.5/3N PLS6-C3.5/3N PLS6-D3.5/3N
4 PLS6-B4/3N PLS6-C4/3N PLS6-D4/3N
5 PLS6-B5/3N PLS6-C5/3N PLS6-D5/3N
6 PLS6-B6/3N PLS6-C6/3N PLS6-D6/3N
8 PLS6-B8/3N PLS6-C8/3N PLS6-D8/3N
10 PLS6-B10/3N PLS6-C10/3N PLS6-D10/3N
12 PLS6-B12/3N PLS6-C12/3N PLS6-D12/3N
13 PLS6-B13/3N PLS6-C13/3N PLS6-D13/3N
15 PLS6-B15/3N PLS6-C15/3N PLS6-D15/3N
16 PLS6-B16/3N PLS6-C16/3N PLS6-D16/3N
20 PLS6-B20/3N PLS6-C20/3N PLS6-D20/3N
25 PLS6-B25/3N PLS6-C25/3N PLS6-D25/3N
32 PLS6-B32/3N PLS6-C32/3N PLS6-D32/3N
40 PLS6-B40/3N PLS6-C40/3N PLS6-D40/3N
50 PLS6-B50/3N PLS6-C50/3N PLS6-D50/3N *
63 PLS6-B63/3N PLS6-C63/3N PLS6-D63/3N *
Note * PLS6-D50/3N and -D63/3N available July 2007.
Miniature Circuit Breakers6 kA range · Triple-Pole & Neutral
Toggle Colours
2 A 4 A 6 A 10 A 13 A 16 A
20 A 25 A 32 A 40 A 50 A 63 A
70
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
71
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
Auxiliary ContactsRated Current
Ith (A) Contact Function Rated Voltage(V AC)
Minimum Current (mA DC) Part Number
6 1 N/O + 1 N/C 250 10 ZP-IHK
6 1 C/O 250 10 ZP-WHK
6 2 C/O 250 10 ZP-NHK
Note 2 x WHK auxiliary or 2 x IHK auxiliary contacts can be added together.1 contact on NHK auxiliary can be configured as trip signal indicator.
Shunt TripOperational Voltage
AC (V)Operational Voltage
DC (V) Part Number
110–415 110–220 ZP-ASA230
12–110 12–60 ZP-ASA24
Undervoltage Release
Tripping Type Making Threshold Breaking Threshold Rated Voltage AC (V) Part Number
Instantaneous 80% 50% 115 Z-USA/115
80% 50% 230 Z-USA/4230
80% 50% 400 Z-USA/400
Delayed 80% 50% 115 Z-USD/115
80% 50% 230 Z-USD/4230
80% 50% 400 Z-USD/400
Switch Interlockfor padlockable facility
Description Part Number
Toggle attachment for padlock IS/SPE-1TE
Note Padlock not supplied.
Miniature Circuit Breakers6 kA range · Accessories
72
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)73
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
Miniature Circuit Breakers6 kA range · Single-Pole & Neutral
Miniature Circuit Breakers · Single-Pole + Neutral1 module width · 6 kA · EN 60898
Rated Current In (A) B Curve C Curve
2 – PLN6-C2/1N
4 – PLN6-C4/1N
6 PLN6-B6/1N PLN6-C6/1N
10 PLN6-B10/1N PLN6-C10/1N
13 PLN6-B13/1N PLN6-C13/1N
16 PLN6-B16/1N PLN6-C16/1N
20 PLN6-B20/1N PLN6-C20/1N
25 PLN6-B25/1N PLN6-C25/1N
32 PLN6-B32/1N PLN6-C32/1N
40 PLN6-B40/1N PLN6-C40/1N
Auxiliary ContactsRated Current
Ith (A) Contact Function Rated VoltageAC (V)
Minimum Current (mA DC) Part Number
6 1 N/O + 1 N/C 250 10 ZP-IHK
6 1 C/O 250 10 ZP-WHK
6 2 C/O 250 10 ZP-NHK
Note 2 x WHK auxiliary or 2 x IHK auxiliary contacts can be added together.1 contact on NHK auxiliary can be configured as trip signal indicator.
Shunt TripOperational Voltage
AC (V)Operational Voltage
DC (V) Part Number
110–415 110–220 ZP-ASA230
12–110 12–60 ZP-ASA24
Undervoltage Release
Tripping Type Making Threshold Breaking Threshold Rated Voltage AC (V) Part Number
Instantaneous 0.8 0.5 115 Z-USA/115
0.8 0.5 230 Z-USA/4230
0.8 0.5 400 Z-USA/400
Delayed 0.8 0.5 115 Z-USD/115
0.8 0.5 230 Z-USD/4230
0.8 0.5 400 Z-USD/400
72
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
73
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
Miniature Circuit Breakers10 kA range · Single-Pole
Miniature Circuit Breakers · Single-Pole10 kA · IEC 60898
Rated Current In (A) B Curve C Curve D Curve
0.16 – PLSM-C0.16/1 –
0.25 – PLSM-C0.25/1 –
0.5 – PLSM-C0.5/1 PLSM-D0.5/1
0.75 – PLSM-C0.75/1 –
1 PLSM-B1/1 PLSM-C1/1 PLSM-D1/1
1.5 PLSM-B1.5/1 PLSM-C1.5/1 PLSM-D1.5/1
1.6 PLSM-B1.6/1 PLSM-C1.6/1 PLSM-D1.6/1
2 PLSM-B2/1 PLSM-C2/1 PLSM-D2/1
2.5 PLSM-B2.5/1 PLSM-C2.5/1 PLSM-D2.5/1
3 PLSM-B3/1 PLSM-C3/1 PLSM-D3/1
3.5 PLSM-B3.5/1 PLSM-C3.5/1 PLSM-D3.5/1
4 PLSM-B4/1 PLSM-C4/1 PLSM-D4/1
5 PLSM-B5/1 PLSM-C5/1 PLSM-D5/1
6 PLSM-B6/1 PLSM-C6/1 PLSM-D6/1
8 PLSM-B8/1 PLSM-C8/1 PLSM-D8/1
10 PLSM-B10/1 PLSM-C10/1 PLSM-D10/1
12 PLSM-B12/1 PLSM-C12/1 PLSM-D12/1
13 PLSM-B13/1 PLSM-C13/1 PLSM-D13/1
15 PLSM-B15/1 PLSM-C15/1 PLSM-D15/1
16 PLSM-B16/1 PLSM-C16/1 PLSM-D16/1
20 PLSM-B20/1 PLSM-C20/1 PLSM-D20/1
25 PLSM-B25/1 PLSM-C25/1 PLSM-D25/1
32 PLSM-B32/1 PLSM-C32/1 PLSM-D32/1
40 PLSM-B40/1 PLSM-C40/1 PLSM-D40/1
50 PLSM-B50/1 PLSM-C50/1 PLSM-D50/1 *
63 PLSM-B63/1 PLSM-C63/1 PLSM-D63/1 *
Note * PLSM-D50/1 and -D63/1 available July 2007.
Toggle Colours
2 A 4 A 6 A 10 A 13 A 16 A
20 A 25 A 32 A 40 A 50 A 63 A
74
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)75
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
Miniature Circuit Breakers10 kA range · Double-Pole
Miniature Circuit Breakers · Double-Pole10 kA · IEC 60898
Rated Current In (A) B Curve C Curve D Curve
0.16 – PLSM-C0.16/2 –
0.25 – PLSM-C0.25/2 –
0.5 – PLSM-C0.5/2 PLSM-D0.5/2
0.75 – PLSM-C0.75/2 –
1 PLSM-B1/2 PLSM-C1/2 PLSM-D1/2
1.5 PLSM-B1.5/2 PLSM-C1.5/2 PLSM-D1.5/2
1.6 PLSM-B1.6/2 PLSM-C1.6/2 PLSM-D1.6/2
2 PLSM-B2/2 PLSM-C2/2 PLSM-D2/2
2.5 PLSM-B2.5/2 PLSM-C2.5/2 PLSM-D2.5/2
3 PLSM-B3/2 PLSM-C3/2 PLSM-D3/2
3.5 PLSM-B3.5/2 PLSM-C3.5/2 PLSM-D3.5/2
4 PLSM-B4/2 PLSM-C4/2 PLSM-D4/2
5 PLSM-B5/2 PLSM-C5/2 PLSM-D5/2
6 PLSM-B6/2 PLSM-C6/2 PLSM-D6/2
8 PLSM-B8/2 PLSM-C8/2 PLSM-D8/2
10 PLSM-B10/2 PLSM-C10/2 PLSM-D10/2
12 PLSM-B12/2 PLSM-C12/2 PLSM-D12/2
13 PLSM-B13/2 PLSM-C13/2 PLSM-D13/2
15 PLSM-B15/2 PLSM-C15/2 PLSM-D15/2
16 PLSM-B16/2 PLSM-C16/2 PLSM-D16/2
20 PLSM-B20/2 PLSM-C20/2 PLSM-D20/2
25 PLSM-B25/2 PLSM-C25/2 PLSM-D25/2
32 PLSM-B32/2 PLSM-C32/2 PLSM-D32/2
40 PLSM-B40/2 PLSM-C40/2 PLSM-D40/2
50 PLSM-B50/2 PLSM-C50/2 PLSM-D50/2 *
63 PLSM-B63/2 PLSM-C63/2 PLSM-D63/2 *
Note * PLSM-D50/2 and -D63/2 available July 2007.
Toggle Colours
2 A 4 A 6 A 10 A 13 A 16 A
20 A 25 A 32 A 40 A 50 A 63 A
74
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
75
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
Miniature Circuit Breakers · Triple-Pole10 kA · IEC 60898
Rated Current In (A) B Curve C Curve D Curve
0.16 – PLSM-C0.16/3 –
0.25 – PLSM-C0.25/3 –
0.5 – PLSM-C0.5/3 PLSM-D0.5/3
0.75 – PLSM-C0.75/3 –
1 PLSM-B1/3 PLSM-C1/3 PLSM-D1/3
1.5 PLSM-B1.5/3 PLSM-C1.5/3 PLSM-D1.5/3
1.6 PLSM-B1.6/3 PLSM-C1.6/3 PLSM-D1.6/3
2 PLSM-B2/3 PLSM-C2/3 PLSM-D2/3
2.5 PLSM-B2.5/3 PLSM-C2.5/3 PLSM-D2.5/3
3 PLSM-B3/3 PLSM-C3/3 PLSM-D3/3
3.5 PLSM-B3.5/3 PLSM-C3.5/3 PLSM-D3.5/3
4 PLSM-B4/3 PLSM-C4/3 PLSM-D4/3
5 PLSM-B5/3 PLSM-C5/3 PLSM-D5/3
6 PLSM-B6/3 PLSM-C6/3 PLSM-D6/3
8 PLSM-B8/3 PLSM-C8/3 PLSM-D8/3
10 PLSM-B10/3 PLSM-C10/3 PLSM-D10/3
12 PLSM-B12/3 PLSM-C12/3 PLSM-D12/3
13 PLSM-B13/3 PLSM-C13/3 PLSM-D13/3
15 PLSM-B15/3 PLSM-C15/3 PLSM-D15/3
16 PLSM-B16/3 PLSM-C16/3 PLSM-D16/3
20 PLSM-B20/3 PLSM-C20/3 PLSM-D20/3
25 PLSM-B25/3 PLSM-C25/3 PLSM-D25/3
32 PLSM-B32/3 PLSM-C32/3 PLSM-D32/3
40 PLSM-B40/3 PLSM-C40/3 PLSM-D40/3
50 PLSM-B50/3 PLSM-C50/3 PLSM-D50/3 *
63 PLSM-B63/3 PLSM-C63/3 PLSM-D63/3 *
Note * PLSM-D50/3 and -D63/3 available July 2007.
Miniature Circuit Breakers10 kA range · Triple-Pole
Toggle Colours
2 A 4 A 6 A 10 A 13 A 16 A
20 A 25 A 32 A 40 A 50 A 63 A
76
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)77
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
Miniature Circuit Breakers10 kA range · Four-Pole
Miniature Circuit Breakers · Four-Pole10 kA · IEC 60898
Rated Current In (A) B Curve C Curve D Curve
0.16 – PLSM-C0.16/4 –
0.25 – PLSM-C0.25/4 –
0.5 – PLSM-C0.5/4 PLSM-D0.5/4
0.75 – PLSM-C0.75/4 –
1 PLSM-B1/4 PLSM-C1/4 PLSM-D1/4
1.5 PLSM-B1.5/4 PLSM-C1.5/4 PLSM-D1.5/4
1.6 PLSM-B1.6/4 PLSM-C1.6/4 PLSM-D1.6/4
2 PLSM-B2/4 PLSM-C2/4 PLSM-D2/4
2.5 PLSM-B2.5/4 PLSM-C2.5/4 PLSM-D2.5/4
3 PLSM-B3/4 PLSM-C3/4 PLSM-D3/4
3.5 PLSM-B3.5/4 PLSM-C3.5/4 PLSM-D3.5/4
4 PLSM-B4/4 PLSM-C4/4 PLSM-D4/4
5 PLSM-B5/4 PLSM-C5/4 PLSM-D5/4
6 PLSM-B6/4 PLSM-C6/4 PLSM-D6/4
8 PLSM-B8/4 PLSM-C8/4 PLSM-D8/4
10 PLSM-B10/4 PLSM-C10/4 PLSM-D10/4
12 PLSM-B12/4 PLSM-C12/4 PLSM-D12/4
13 PLSM-B13/4 PLSM-C13/4 PLSM-D13/4
15 PLSM-B15/4 PLSM-C15/4 PLSM-D15/4
16 PLSM-B16/4 PLSM-C16/4 PLSM-D16/4
20 PLSM-B20/4 PLSM-C20/4 PLSM-D20/4
25 PLSM-B25/4 PLSM-C25/4 PLSM-D25/4
32 PLSM-B32/4 PLSM-C32/4 PLSM-D32/4
40 PLSM-B40/4 PLSM-C40/4 PLSM-D40/4
50 PLSM-B50/4 PLSM-C50/4 PLSM-D50/4 *
63 PLSM-B63/4 PLSM-C63/4 PLSM-D63/4 *
Note * PLSM-D50/4 and D63/4 available July 2007.
Toggle Colours
2 A 4 A 6 A 10 A 13 A 16 A
20 A 25 A 32 A 40 A 50 A 63 A
76
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
77
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
Miniature Circuit Breakers · Triple-Pole & Neutral10 kA · IEC 60898
Rated Current In (A) B Curve C Curve D Curve
0.16 – PLSM-C0,16/3N –
0.25 – PLSM-C0.25/3N –
0.5 – PLSM-C0.5/3N PLSM-D0.5/3N
0.75 – PLSM-C0.75/3N –
1 PLSM-B1/3N PLSM-C1/3N PLSM-D1/3N
1.5 PLSM-B1.5/3N PLSM-C1.5/3N PLSM-D1.5/3N
1.6 PLSM-B1.6/3N PLSM-C1.6/3N PLSM-D1.6/3N
2 PLSM-B2/3N PLSM-C2/3N PLSM-D2/3N
2.5 PLSM-B2.5/3N PLSM-C2.5/3N PLSM-D2.5/3N
3 PLSM-B3/3N PLSM-C3/3N PLSM-D3/3N
3.5 PLSM-B3.5/3N PLSM-C3.5/3N PLSM-D3.5/3N
4 PLSM-B4/3N PLSM-C4/3N PLSM-D4/3N
5 PLSM-B5/3N PLSM-C5/3N PLSM-D5/3N
6 PLSM-B6/3N PLSM-C6/3N PLSM-D6/3N
8 PLSM-B8/3N PLSM-C8/3N PLSM-D8/3N
10 PLSM-B10/3N PLSM-C10/3N PLSM-D10/3N
12 PLSM-B12/3N PLSM-C12/3N PLSM-D12/3N
13 PLSM-B13/3N PLSM-C13/3N PLSM-D13/3N
15 PLSM-B15/3N PLSM-C15/3N PLSM-D15/3N
16 PLSM-B16/3N PLSM-C16/3N PLSM-D16/3N
20 PLSM-B20/3N PLSM-C20/3N PLSM-D20/3N
25 PLSM-B25/3N PLSM-C25/3N PLSM-D25/3N
32 PLSM-B32/3N PLSM-C32/3N PLSM-D32/3N
40 PLSM-B40/3N PLSM-C40/3N PLSM-D40/3N
50 PLSM-B50/3N PLSM-C50/3N PLSM-D50/3N *
63 PLSM-B63/3N PLSM-C63/3N PLSM-D63/3N *
Note * PLSM-D50/3N and -D63/3N available July 2007.
Toggle Colours
2 A 4 A 6 A 10 A 13 A 16 A
20 A 25 A 32 A 40 A 50 A 63 A
Miniature Circuit Breakers10 kA range · Triple-Pole & Neutral
78
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)79
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
Miniature Circuit Breakers10 kA range · Single-Pole & Neutral
Miniature Circuit Breakers · Single-Pole and Neutral2 module width ·10 kA · IEC 60898
Rated Current In (A) B Curve C Curve D Curve
0.16 – PLZM-C0.16/1N –
0.25 – PLZM-C0.25/1N –
0.5 – PLZM-C0.5/1N PLZM-D0.5/1N
0.75 – PLZM-C0.75/1N –
1 PLZM-B1/1N PLZM-C1/1N PLZM-D1/1N
1.5 PLZM-B1.5/1N PLZM-C1.5/1N PLZM-D1.5/1N
1.6 PLZM-B1.6/1N PLZM-C1.6/1N PLZM-D1.6/1N
2 PLZM-B2/1N PLZM-C2/1N PLZM-D2/1N
2.5 PLZM-B2.5/1N PLZM-C2.5/1N PLZM-D2.5/1N
3 PLZM-B3/1N PLZM-C3/1N PLZM-D3/1N
3.5 PLZM-B3.5/1N PLZM-C3.5/1N PLZM-D3.5/1N
4 PLZM-B4/1N PLZM-C4/1N PLZM-D4/1N
5 PLZM-B5/1N PLZM-C5/1N PLZM-D5/1N
6 PLZM-B6/1N PLZM-C6/1N PLZM-D6/1N
8 PLZM-B8/1N PLZM-C8/1N PLZM-D8/1N
10 PLZM-B10/1N PLZM-C10/1N PLZM-D10/1N
12 PLZM-B12/1N PLZM-C12/1N PLZM-D12/1N
13 PLZM-B13/1N PLZM-C13/1N PLZM-D13/1N
15 PLZM-B15/1N PLZM-C15/1N PLZM-D15/1N
16 PLZM-B16/1N PLZM-C16/1N PLZM-D16/1N
20 PLZM-B20/1N PLZM-C20/1N PLZM-D20/1N
25 PLZM-B25/1N PLZM-C25/1N PLZM-D25/1N
32 PLZM-B32/1N PLZM-C32/1N PLZM-D32/1N
40 PLZM-B40/1N PLZM-C40/1N PLZM-D40/1N
50 PLZM-B50/1N PLZM-C50/1N –
63 PLZM-B63/1N PLZM-C63/1N –
Toggle Colours
2 A 4 A 6 A 10 A 13 A 16 A
20 A 25 A 32 A 40 A 50 A 63 A
78
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
79
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
Auxiliary ContactsRated Current
Ith (A) Contact Function Rated Voltage(V AC)
Minimum current (mA DC) Part Number
6 1 N/O + 1 N/C 250 10 ZP-IHK
6 1 C/O 250 10 ZP-WHK
6 2 C/O 250 10 ZP-NHK
Note 2 x WHK auxiliary or 2 x IHK auxiliary contacts can be added together.1 contact on NHK auxiliary can be configured as trip signal indicator.
Shunt TripOperational Voltage
AC (V)Operational Voltage
DC (V) Part Number
110–415 110–220 ZP-ASA230
12–110 12–60 ZP-ASA24
Undervoltage Release
Tripping Type Making Threshold Breaking Threshold Rated Voltage AC (V) Part Number
Instantaneous 80% 50% 115 Z-USA/115
80% 50% 230 Z-USA/4230
80% 50% 400 Z-USA/400
Delayed 80% 50% 115 Z-USD/115
80% 50% 230 Z-USD/4230
80% 50% 400 Z-USD/400
Switch Interlockfor padlockable facility
Description Part Number
Toggle attachment for padlock IS/SPE-1TE
Note Padlock not supplied.
Miniature Circuit Breakers10 kA range · Accessories
80
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)81
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
Miniature Circuit Breakers25 kA range
Miniature Circuit Breakers · up to 25 kA · 1.5 module width · EN 60947-2Single-Pole
Rated Current In (A) B Curve C Curve D Curve
20 PLHT-B20 PLHT-C20 PLHT-D20
25 PLHT-B25 PLHT-C25 PLHT-D25
32 PLHT-B32 PLHT-C32 PLHT-D32
40 PLHT-B40 PLHT-C40 PLHT-D40
50 PLHT-B50 PLHT-C50 PLHT-D50
63 PLHT-B63 PLHT-C63 PLHT-D63
80 PLHT-B80 PLHT-C80 PLHT-D80
100 PLHT-B100 PLHT-C100 PLHT-D100
125 PLHT-B125 PLHT-C125 –
Double-Pole
Rated Current In (A) B Curve C Curve D Curve
20 PLHT-B20/2 PLHT-C20/2 PLHT-D20/2
25 PLHT-B25/2 PLHT-C25/2 PLHT-D25/2
32 PLHT-B32/2 PLHT-C32/2 PLHT-D32/2
40 PLHT-B40/2 PLHT-C40/2 PLHT-D40/2
50 PLHT-B50/2 PLHT-C50/2 PLHT-D50/2
63 PLHT-B63/2 PLHT-C63/2 PLHT-D63/2
80 PLHT-B80/2 PLHT-C80/2 PLHT-D80/2
100 PLHT-B100/2 PLHT-C100/2 PLHT-D100/2
125 PLHT-B125/2 PLHT-C125/2 –
Triple-Pole
Rated Current In (A) B Curve C Curve D Curve
20 PLHT-B20/3 PLHT-C20/3 PLHT-D20/3
25 PLHT-B25/3 PLHT-C25/3 PLHT-D25/3
32 PLHT-B32/3 PLHT-C32/3 PLHT-D32/3
40 PLHT-B40/3 PLHT-C40/3 PLHT-D40/3
50 PLHT-B50/3 PLHT-C50/3 PLHT-D50/3
63 PLHT-B63/3 PLHT-C63/3 PLHT-D63/3
80 PLHT-B80/3 PLHT-C80/3 PLHT-D80/3
100 PLHT-B100/3 PLHT-C100/3 PLHT-D100/3
125 PLHT-B125/3 PLHT-C125/3 –
Four-Pole
Rated Current In (A) B Curve C Curve D Curve
20 PLHT-B20/4 PLHT-C20/4 PLHT-D20/4
25 PLHT-B25/4 PLHT-C25/4 PLHT-D25/4
32 PLHT-B32/4 PLHT-C32/4 PLHT-D32/4
40 PLHT-B40/4 PLHT-C40/4 PLHT-D40/4
50 PLHT-B50/4 PLHT-C50/4 PLHT-D50/4
63 PLHT-B63/4 PLHT-C63/4 PLHT-D63/4
80 PLHT-B80/4 PLHT-C80/4 PLHT-D80/4
100 PLHT-B100/4 PLHT-C100/4 PLHT-D100/4
125 PLHT-B125/4 PLHT-C125/4 –
80
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
81
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
Miniature Circuit Breakers25 kA range · Accessories
Miniature Circuit Breakers · up to 25 kA · 1.5 module width · EN 60947-2Triple-Pole and Neutral
Rated Current In (A) B Curve C Curve D Curve
20 PLHT-B20/3N PLHT-C20/3N PLHT-D20/3N
25 PLHT-B25/3N PLHT-C25/3N PLHT-D25/3N
32 PLHT-B32/3N PLHT-C32/3N PLHT-D32/3N
40 PLHT-B40/3N PLHT-C40/3N PLHT-D40/3N
50 PLHT-B50/3N PLHT-C50/3N PLHT-D50/3N
63 PLHT-B63/3N PLHT-C63/3N PLHT-D63/3N
80 PLHT-B80/3N PLHT-C80/3N PLHT-D80/3N
100 PLHT-B100/3N PLHT-C100/3N PLHT-D100/3N
125 PLHT-B125/3N PLHT-C125/3N –
Auxiliary Contacts · for PLHT
Rated Current Ith (A) Contact Function Rated Voltage (V)AC (DC) Minimum Voltage (V) Part Number
8 1 N/O + 1 N/C 440 (230) 24 Z-LHK
Shunt Trip · for PLHT
Tripping Time (ms) Max Current Switch-on AC (A)
Operational VoltageAC (V) Part Number
< 20 2 110–415 Z-LHASA/230
< 20 18 12–60 Z-LHASA/24
82
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)83
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)
Miniature Circuit BreakersTechnical Data
Miniature Circuit Breakers · PLS… , PLZ…
General
Design according to PLSM: IEC EN 60898
Electrical
Current ratings 0.16 A to 63 ARated voltage 230/400 VCharacteristics B, C, DRated short-circuit strength PLSM, PLZM: 10 kA
PLS6: 6 kAEndurance ≥ 8,000 operating cycles
Mechanical
Frame size 45 mmDevice height 80 mmDevice width 17.5 mm per poleDIN rail mountable: on symmetrical DIN railTerminal capacity 1–25 mm2
Positive contact indication (red–green) in accordance with BS 7671
Dimensions (mm)
PLN
PLSM
PLHT
Miniature Circuit Breakers · PLN
General
Design according to IEC EN 60898
Electrical
Current ratings 2 A to 40 ARated voltage 230 VCharacteristics B, CRated short-circuit strength PLN6: 6 kAEndurance ≥ 8,000 operating cycles
Mechanical
Frame size 45 mmDevice height 80 mmDevice width 17.5 mm per poleDIN rail mountable: on symmetrical DIN railTerminal capacity 1–16 mm2
Positive contact indication (red–green) in accordance with BS 7671
Miniature Circuit Breakers · PLHT
General
Design according to IEC EN 60947-2
Electrical
Current ratings 0.16 A to 63 ARated voltage 230/400 V AC 60 V DCCharacteristics B, C, DRated short-circuit strength MCB current rating B,C 20 A – 63 A, 25 kA MCB current rating B,C 80 A – 100 A, 20 kA MCB current rating B,C 125 A, 15 kA MCB current rating D 63 A, 25 kA MCB current rating D 80 A, 20 kA MCB current rating D 100 A, 15 kAEndurance ≥ 20,000 operating cycles
Mechanical
Frame size 45 mmDevice height 90 mmDevice width 27 mm per poleDIN rail mountable: on symmetrical DIN railTerminal capacity 2.5–50 mm2
Positive contact indication (red–green) in accordance with BS 7671
82
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Min
iatu
re C
ircu
it B
reak
ers
(MCB
s)
83
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)
Residual Current Devices (RCDs)Introduction
Residual Current Devices (RCDs)Moeller’s range of Residual Current Devices (RCDs) provide solutions for a wide range of applications. The range is completed with a comprehensive selection of accessories, from auxiliaries to automatic reset devices for those applications too remote for manual intervention.
2-Pole RCDstandard AC
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 500 mA
25 PFIM-25/2/003 PFIM-25/2/01 PFIM-25/2/03 PFIM-25/2/05
40 PFIM-40/2/003 PFIM-40/2/01 PFIM-40/2/03 PFIM-40/2/05
63 PFIM-63/2/003 PFIM-63/2/01 PFIM-63/2/03 PFIM-63/2/05
80 PFIM-80/2/003 PFIM-80/2/01 PFIM-80/2/03 PFIM-80/2/05
100 PFIM-100/2/003 PFIM-100/2/01 PFIM-100/2/03 PFIM-100/2/05
16 * PFIM-16/2/001 – – –
Note * 16 A RCD is rated for 10 mA Earth leakage.
4-Pole RCDstandard AC
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 500 mA
25 PFIM-25/4/003 PFIM-25/4/01 PFIM-25/4/03 PFIM-25/4/05
40 PFIM-40/4/003 PFIM-40/4/01 PFIM-40/4/03 PFIM-40/4/05
63 PFIM-63/4/003 PFIM-63/4/01 PFIM-63/4/03 PFIM-63/4/05
80 PFIM-80/4/003 PFIM-80/4/01 PFIM-80/4/03 PFIM-80/4/05
100 PFIM-100/4/003 PFIM-100/4/01 PFIM-100/4/03 PFIM-100/4/05
84
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)85
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)
2-Pole RCD · Type Asensitive to residual pulsating DC
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 500 mA
16 PFIM-16/2/003-A – – –
25 PFIM-25/2/003-A PFIM-25/2/01-A PFIM-25/2/03-A –
40 PFIM-40/2/003-A PFIM-40/2/01-A PFIM-40/2/03-A PFIM-40/2/05-A
63 PFIM-63/2/003-A PFIM-63/2/01-A PFIM-63/2/03-A PFIM-63/2/05-A
80 – – – –
100 – PFIM-100/2/01-A PFIM-100/2/03-A –
16 * PFIM-16/2/001-A – – –
Note * 16 A RCD is rated for 10mA Earth leakage.
4-Pole RCD · Type Asensitive to residual pulsating DC
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 500 mA
25 PFIM-25/4/003-A PFIM-25/4/01-A PFIM-25/4/03-A PFIM-25/4/05-A
40 PFIM-40/4/003-A PFIM-40/4/01-A PFIM-40/4/03-A PFIM-40/4/05-A
63 PFIM-63/4/003-A PFIM-63/4/01-A PFIM-63/4/03-A PFIM-63/4/05-A
80 PFIM-80/4/003-A – PFIM-80/4/03-A –
100 PFIM-100/4/003-A PFIM-100/4/01-A PFIM-100/4/03-A PFIM-100/4/05-A
Residual Current Devices (RCDs)Type A & Type G
2-Pole RCD · Type Gstandard AC, time delay
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 500 mA
25 PFIM-25/2/003-G PFIM-25/2/01-G – –
40 PFIM-40/2/003-G PFIM-40/2/01-G – –
100 – PFIM-100/2/01/-G – –
4-Pole RCD · Type Gstandard AC, time delay
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 500 mA
40 PFIM-40/4/003-G PFIM-40/4/01-G – –
63 PFIM-63/4/003-G PFIM-63/4/01-G – –
80 PFIM-80/4/003-G – – –
100 PFIM-100/4/003-G – PFIM-100/4/03-G –
84
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)
85
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)
2-Pole RCD · Type G/Asensitive to residual pulsating DC, time delay
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 500 mA
40 PFIM-40/2/003-G/A – – –
63 PFIM-63/2/003-G/A – – –
80 PFIM-80/2/003-G/A – – –
100 PFIM-100/2/003-G/A – – –
4-Pole RCD · Type G/Asensitive to residual pulsating DC, time delay
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 500 mA
40 PFIM-40/4/003-G/A – – –
63 PFIM-63/4/003-G/A – – –
80 PFIM-80/4/003-G/A – – –
100 PFIM-100/4/003-G/A – – –
4-Pole RCD · Type RX-ray application
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 500 mA
63 PFIM-63/4/003-R – – –
100 PFIM-100/4/003-R – – –
Residual Current Devices (RCDs)Type G/A · Type R
86
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)87
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)
4-Pole RCD · Type Sselective
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 500 mA
25 – – PFIM-25/4/03-S –
80 – PFIM-80/4/01-S -– –
4-Pole RCD · Type S/Asensitive to residual pulsating DC, selective
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 500 mA
25 – PFIM-25/4/01-S/A – –
40 – PFIM-40/4/01-S/A PFIM-40/4/03-S/A –
63 – PFIM-63/4/01-S/A PFIM-63/4/03-S/A –
80 – – PFIM-80/4/03-S/A –
100 – – PFIM-100/4/03-S/A –
4-Pole RCD · Type Uselective + surge current-proof 5 kA, frequency converter-proof
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 500 mA
40 – PFIM-40/4/01-U PFIM-40/4/03-U –
63 – PFIM-63/4/01-U PFIM-63/4/03-U –
80 – PFIM-80/4/01-U PFIM-80/4/03-U –
100 – PFIM-100/4/01-U PFIM-100/4/03-U –
4-Pole RCD · Type Ushort time delay + surge current-proof 3 kA, frequency converter-proof
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 500 mA
40 PFIM-63/4/003-U – – –
Residual Current Devices (RCDs)Type S · Type S/A · Type U
2-Pole RCD · Type Sselective
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 500 mA
40 – PFIM-40/2/01-S PFIM-40/2/03-S –
86
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)
87
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)
Auxiliary Contacts · for PFIM
Description Rated CurrentAC11 @ 250 V AC
Minimum Volts per Contact Part Number
Auxilliary contact · 1 N/O + 1 N/C 8 A 24 V AC/DC Z-HK
Trip auxilliary contact · 2 C/O 4 A 5 V DC Z-NHK
Note Z-NHK has one change-over contact configurable for trip indication.
Trip Module for remote tripping · for PFIM
Description Rated Tripping Current A Rated Voltage Part Number
Trip module with 1 N/O + 1 Ω 0.1 – 0.3 230(400) V AC Z-FAM
Automatic Re-closing Device · for PFIM
Description Relay Output Operating Voltages Part Number
230 V AC, 5 x re-closing device 5 A / 250 V 220–240 V AC Z-FW-LP
24–48 V DC, 5 x re-closing device 5 A / 250 V 24–48 V DC Z-FW-LPD
Add on remote control module – 24–230 V AC/DC Z-FW-MO
Residual Current Devices (RCDs)Accessories
Sealing Cover Set · for PFIM
Description Part Number
2-pole sealing cover set Z-RC/AK-2TE
4-pole sealing cover set Z-RC/AK-4TE
88
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)89
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)
2-Pole RCD · Conditional Surge Current Proof0.5µs/100 kHz ring-wave tested · standard AC
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 500 mA
125 PFDM-125/2/003 – PFDM-125/2/03 –
4-Pole RCD · Conditional Surge Current Proof0.5µs/100 kHz ring-wave tested · standard AC
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 500 mA
125 PFDM-125/4/003 PFDM-125/4/01 PFDM-125/4/03 PFDM-125/4/05
4-Pole RCD · Conditional Surge Current Proof · Type A0.5µs/100 kHz ring-wave tested · sensitive to residual pulsating DC
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 500 mA
125 PFDM-125/4/003-A PFDM-125/4/01-A PFDM-125/4/03-A PFDM-125/4/05-A
4-Pole RCD · Conditional Surge Current Proof · Type S/A0.5µs/100 kHz ring-wave tested · sensitive to residual pulsating DC · selective
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 500 mA
125 – – PFDM-125/4/03-S/A –
Auxiliary Contacts · for PFDM
Description Rated CurrentAC11 @ 230 V AC Part Number
Auxilliary contact 1 C/O + 1 N/C 6 A Z-HD
Residual Current Devices (RCDs)Conditional Surge Current Proof RCDs
88
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)
89
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)
2-Pole Add-on RCD · Standard AC
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 500 mA 1 A
40 PBSM-402/003 PBSM-402/01 PBSM-402/03 PBSM-402/05 PBSM-402/1
63 PBSM-632/003 PBSM-632/01 PBSM-632/03 PBSM-632/05 PBSM-632/1
3-Pole Add-on RCD · Standard AC
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 500 mA 1 A
40 PBSM-403/003 PBSM-403/01 PBSM-403/03 PBSM-403/05 PBSM-403/1
63 PBSM-633/003 PBSM-633/01 PBSM-633/03 PBSM-633/05 PBSM-633/1
4-Pole Add-on RCD · Standard AC
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 500 mA 1 A
40 PBSM-404/003 PBSM-404/01 PBSM-404/03 PBSM-404/05 PBSM-404/1
63 PBSM-634/003 PBSM-634/01 PBSM-634/03 PBSM-634/05 PBSM-634/1
2-Pole Add-on RCD · Type Asensitive to residual pulsating DC
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 1 A
40 PBSM-402/003-A PBSM-402/01-A PBSM-402/03-A PBSM-402/1-A
63 PBSM-632/003-A PBSM-632/01-A PBSM-632/03-A PBSM-632/1-A
3-Pole Add-on RCD · Type Asensitive to residual pulsating DC
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 1 A
40 PBSM-403/003-A PBSM-403/01-A PBSM-403/03-A PBSM-403/1-A
63 PBSM-633/003-A PBSM-633/01-A PBSM-633/03-A PBSM-633/1-A
4-Pole Add-on RCD · Type Asensitive to residual pulsating DC
Tripping CurrentRated Current In (A) 30 mA 100 mA 300 mA 1 A
40 PBSM-404/003-A PBSM-404/01-A PBSM-404/03-A PBSM-404/1-A
63 PBSM-634/003-A PBSM-634/01-A PBSM-634/03-A PBSM-634/1-A
Residual Current Devices (RCDs)Add-on RCDs for MCBs
90
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)91
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)
2-Pole Add-on RCD · Type Sselective time delay
Tripping CurrentRated Current In (A) 100 mA 300 mA 1 A
40 PBSM-402/01-S PBSM-402/03-S PBSM-402/1-S
63 PBSM-632/01-S PBSM-632/03-S PBSM-632/1-S
3-Pole Add-on RCD · Type Sselective time delay
Tripping CurrentRated Current In (A) 100 mA 300 mA 1 A
40 PBSM-403/01-S PBSM-403/03-S PBSM-403/1-S
63 PBSM-633/01-S PBSM-633/03-S PBSM-633/1-S
4-Pole Add-on RCD · Type Sselective time delay
Tripping CurrentRated Current In (A) 100 mA 300 mA 1 A
40 PBSM-404/01-S PBSM-404/03-S PBSM-404/1-S
63 PBSM-634/01-S PBSM-634/03-S PBSM-634/1-S
Automatic Re-closing Device
Description Relay Output Operating Voltages Part Number
230 V AC, 5 x re-closing device 5 A / 250 V 220–240 V AC Z-FW-LP
24–48 V DC, 5 x re-closing device 5 A / 250 V 24–48 V DC Z-FW-LPD
Add-on remote control module – 24–230 V AC/DC Z-FW-MO
Residual Current Devices (RCDs)Add-on RCDs for MCBs
2, 3 and 4-Pole Add-on RCD · Type Gstandard AC, time delay
Poles and Tripping CurrentRated Current In (A) 2-Pole 30 mA 3-Pole 30 mA 4-Pole 30 mA
40 PBSM-402/003-G PBSM-403/003-G PBSM-404/003-G
90
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)
91
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)
2-Pole Add-on RCD · Standard AC
Tripping CurrentRated Current In (A) 30 mA 300 mA 500 mA 1 A
80 PBHT-80/2/003 PBHT-80/2/03 PBHT-80/2/05 PBHT-80/2/1
125 PBHT-125/2/003 PBHT-125/2/03 PBHT-125/2/05 PBHT-125/2/1
4-Pole Add-on RCD · Standard AC
Tripping CurrentRated Current In (A) 30 mA 300 mA 500 mA 1 A
80 PBHT-80/4/003 PBHT-80/4/03 PBHT-80/4/05 PBHT-80/4/1
125 PBHT-125/4/003 PBHT-125/4/03 PBHT-125/4/05 PBHT-125/4/1
2-Pole Add-on RCD · Type Asensitive to residual pulsating DC
Tripping CurrentRated Current In (A) 30 mA 300 mA 500 mA 1 A
80 PBHT-80/2/003-A PBHT-80/2/03-A PBHT-80/2/05-A PBHT-80/2/1-A
125 PBHT-125/2/003-A PBHT-125/2/03-A PBHT-125/2/05-A PBHT-125/2/1-A
4-Pole Add-on RCD · Type Asensitive to residual pulsating DC
Tripping CurrentRated Current In (A) 30 mA 300 mA 500 mA 1 A
80 PBHT-80/4/003-A PBHT-80/4/03-A PBHT-80/4/05-A PBHT-80/4/1-A
125 PBHT-125/4/003-A PBHT-125/4/03-A PBHT-125/4/05-A PBHT-125/4/1-A
4-Pole Add-on RCD · Type S/Aselective + sensitive to residual pulsating DC
Tripping CurrentRated Current In (A) 30 mA 300 mA 500 mA 1 A
80 – PBHT-80/4/03-S/A PBHT-80/4/05-S/A PBHT-80/4/1-S/A
125 – PBHT-125/4/03-S/A PBHT-125/4/05-S/A PBHT-125/4/1-S/A
Residual Current Devices (RCDs)Add-on RCDs for MCBs
92
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)93
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)
Auxiliary Contact · for PBHT
Description Rated CurrentAC11 @ 230 V AC Part Number
Auxilliary contact 1 C/O + 1 N/C 6 A Z-HD
Shunt Trip · for PBHT
Tripping Time (ms) Max Current Switch-onAC (A)
Operational VoltageAC (V)
Operational VoltageDC (V) Part Number
< 20 3.4 @ 230 V 110–415 110–230 Z-BHASA/230
< 20 1.4–7 12–60 12–60 Z-BHASA/24
Residual Current Devices (RCDs)Add-on RCD Accessories
92
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)
93
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)
Residual Current Devices (RCDs)Technical Data
Residual Current Devices · PFIM
Specifications
RCD IEC EN 61008 ( IEC EN 61009 connected to MCB)Type G acc. to ÖVE E 8601
Electrical
Current ratings 16 A to 100 ARated voltage 230/400 V AC, 2-Pole and 4-PoleRated tripping currents 10, 30, 100, 300, 500 mATripping types Instantaneous Type G, R, U 10 ms delay (Type U 10ms at 30mA, 40ms above 30mA) Type S, U 40 ms delay – with selective disconnecting functionSensitivity AC and Pulsating DCRated short-circuit strength 10 kA (with back-up fuse)Endurance electrical ≥ 4,000 operating cycles mechanical ≥ 20,000 operating cycles
Mechanical
Frame size 45 mmDevice height 80 mmDevice width 2-Pole 35 mm · 4-Pole 70 mmDIN rail mountable on symmetrical DIN railTerminal capacity 1.5–35 mm2 single wire · 2 x 16 mm2 multi wire Positive contact indication (red–green) in accordance with BS 7671
Type Data
Type -A Protects against special forms of residual pulsating DC which have not been smoothedType -G High reliability against unwanted tripping. Compulsory for any circuit where personal injury or damage to property may occur in case of unwanted tripping (ÖVE/ÖNORM E 8001-1 § 12.1.6).Type -G/A Additionally protects against special forms of residual pulsating pulsating DC which have not been smoothed.Special types for X-ray application PFIM-…-RType -R To aviod unwanted tripping due to X-ray devices.Type -S Selective residual current device sensitive to AC, type -S. Compulsory for systems with surge arresters downstream of the RCD (ÖVE/ÖNORM E8001-1 § 12.1.5).Type -S/A Additionally protects against special forms of residual pulsating DC which have not been smoothed.Type -U Suitable for speed-controlled drives with frequency converters in household, trade, and industry. Unwanted tripping is avoided thanks to a tripping characteristic designed particularly for frequency converters.
Dimensions (mm)
PFIM
35
4580
10,5
4,530,5
44
60
5,52P
70
80
4P
94
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)95
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)
Residual Current Devices · PFDM
Specifications
RCD IEC EN 61008 ( IEC EN 61009 connected to MCB)
Electrical
Current ratings 125 ARated voltage 230/400 V AC, 2-Pole and 4-PoleRated tripping currents 30, 100, 300, 500 mATripping types Instantaneous Type S/A 40 ms delay – with selective disconnecting functionSensitivity AC and Pulsating DCRated short-circuit strength 10 kA (with back-up fuse)Endurance electrical ≥ 4,000 operating cycles mechanical ≥ 20,000 operating cycles
Mechanical
Frame size 45 mmDevice height 85 mmDevice width 2-Pole 35 mm · 4-Pole 70 mmDIN rail mountable on symmetrical DIN railTerminal capacity 1.5–50 mm2
Positive contact indication (red–green) in accordance with BS 7671
Type Data
Type -S/A Additionally protects against special forms of residual pulsating DC which have not been smoothed.
Dimensions (mm)
PFDM
Residual Current Devices (RCDs)Technical Data
94
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)
95
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)
Residual Current Devices (RCDs)Technical Data
Residual Current Devices · PBSM
Specifications
RCD IEC EN 61009Type G acc. to ÖVE E 8601
Electrical
Current ratings 40 A to 63 ARated voltage 196/440 V AC, 2-Pole, 3-Pole and 4-PoleRated tripping currents 30, 100, 300, 500, 1000 mATripping types Instantaneous Type G 10 ms delay Type S 40 ms delay – with selective disconnecting functionSensitivity AC and Pulsating DCRated short-circuit strength same as connected PLS
Mechanical
Frame size 45 mmDevice height 90 mmDevice width 2-Pole 70 mm · 3-Pole 107.5 mm · 4-Pole 125 mmDIN rail mountable on symmetrical DIN railTerminal capacity 1 x (1–25) mm2 · 1 x (0.75–16) mm2 flexible cable
Type Data
Type -G High reliability against unwanted tripping. Compulsory for any circuit where personal injury or damage to property may occur in case of unwanted tripping (ÖVE/ÖNORM E 8001-1 § 12.1.6).Type -S Selective residual current device sensitive to AC, type -S. Compulsory for systems with surge arresters downstream of the RCD (ÖVE/ÖNORM E8001-1 § 12.1.5).
Dimensions (mm)
PBSM
125107,5
70
12mm12mm
12mm
4590
9,5
44
60
5,5
4p3p
2p
T
TT
125107,5
70
12mm12mm
12mm
4590
9,5
44
60
5,5
4p3p
2p
T
TT
125107,5
70
12mm12mm
12mm
4590
9,5
44
60
5,5
4p3p
2p
T
TT
96
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)97
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Com
bine
d RC
D/M
CBs
(RCB
Os)
Residual Current Devices (RCDs)Technical Data
Residual Current Devices · PBHT
Specifications
RCD IEC EN 60947-2
Electrical
Current ratings 80 A to 125 ARated voltage 230/400 V AC, 2-Pole, 3-Pole and 4-PoleRated tripping currents 30, 300, 500, 1000 mATripping types Instantaneous Type S 40 ms delay – with selective disconnecting functionSensitivity AC and Pulsating DCRated short-circuit strength Same as connected PLHTEndurance electrical > 1,000 operating cycles mechanical > 8,000 operating cycles
Mechanical
Frame size 45 mmDevice height 90 mmDevice width 95 mmDIN rail mountable on symmetrical-DIN rail, screwed onto PLHTTerminal capacity 2.5–50 mm2 Positive contact indication (red–green) in accordance with BS 7671
Type Data
Type -S Selective residual current device sensitive to AC, type -S. Compulsory for systems with surge arresters downstream of the RCD (ÖVE/ÖNORM E8001-1 § 12.1.5).
Dimensions (mm)
PBHT
96
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Resi
dual
Cur
rent
Dev
ices
(RCD
s)
97
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Com
bine
d RC
D/M
CBs
(RCB
Os)
Combined RCD/MCBs (RCBOs)Introduction
Combined RCD/MCBs (RCBOs)Moeller’s range of Residual Current Circuit Breakers with Overload protection (RCBOs) combine protection for people and circuits in a single device. Choose between double module and single module width, for when space is at a premium.
98
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Com
bine
d RC
D/M
CBs
(RCB
Os)
99
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Com
bine
d RC
D/M
CBs
(RCB
Os)
Combined RCD/MCBs (RCBOs)Single Module
RCBOs · 1+N Pole · B Curve & C Curvestandard AC
Characteristic and Tripping CurrentRated Current (A) B Curve · 30 mA B Curve · 100 mA C Curve · 30 mA C Curve · 100 mA
6 PKS6-6/1N/B/003 PKS6-6/1N/B/01 PKS6-6/1N/C/003 PKS6-6/1N/C/01
8 PKS6-8/1N/B/003 PKS6-8/1N/B/01 PKS6-8/1N/C/003 PKS6-8/1N/C/01
10 PKS6-10/1N/B/003 PKS6-10/1N/B/01 PKS6-10/1N/C/003 PKS6-10/1N/C/01
13 PKS6-13/1N/B/003 PKS6-13/1N/B/01 PKS6-13/1N/C/003 PKS6-13/1N/C/01
16 PKS6-16/1N/B/003 PKS6-16/1N/B/01 PKS6-16/1N/C/003 PKS6-16/1N/C/01
20 PKS6-20/1N/B/003 PKS6-20/1N/B/01 PKS6-20/1N/C/003 PKS6-20/1N/C/01
25 PKS6-25/1N/B/003 PKS6-25/1N/B/01 PKS6-25/1N/C/003 PKS6-25/1N/C/01
32 PKS6-32/1N/B/003 PKS6-32/1N/B/01 PKS6-32/1N/C/003 PKS6-32/1N/C/01
40 PKS6-40/1N/B/003 PKS6-40/1N/B/01 PKS6-40/1N/C/003 PKS6-40/1N/C/01
RCBOs · 1+N Pole · D Curvestandard AC
Rated Current (A)Tripping CurrentD Curve · 100mA
6 PKS6-6/1N/D/01
8 PKS6-8/1N/D/01
10 PKS6-10/1N/D/01
13 PKS6-13/1N/D/01
16 PKS6-16/1N/D/01
20 PKS6-20/1N/D/01
Auxiliary Contacts
Rated Current Ith (A) Contact Function Rated Voltage AC(V)
Minimum Current(mA DC) Part Number
6 1 N/O + 1 N/C 250 10 ZP-IHK
6 1 C/O 250 10 ZP-WHK
6 2 C/O 250 10 ZP-NHK
Note 2 x WHK auxiliary or 2 x IHK auxiliary contacts can be added together.1 contact on NHK auxiliary can be configured as trip signal indicator.
Shunt TripOperational Voltage
AC (V)Operational Voltage
DC (V) Part Number
110–415 110–220 ZP-ASA230
12–110 12–60 ZP-ASA24
98
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Com
bine
d RC
D/M
CBs
(RCB
Os)
99
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Com
bine
d RC
D/M
CBs
(RCB
Os)
Combined RCD/MCBs (RCBOs)Double Module
RCBOs · 1+N Pole · B Curve standard AC
Tripping CurrentRated Current In (A) 10 mA 30 mA 100 mA 300 mA
2 PKNM-2/1N/B/001 PKNM-2/1N/B/003 PKNM-2/1N/B/01 PKNM-2/1N/B/03
4 PKNM-4/1N/B/001 PKNM-4/1N/B/003 PKNM-4/1N/B/01 PKNM-4/1N/B/03
6 PKNM-6/1N/B/001 PKNM-6/1N/B/003 PKNM-6/1N/B/01 PKNM-6/1N/B/03
10 PKNM-10/1N/B/001 PKNM-10/1N/B/003 PKNM-10/1N/B/01 PKNM-10/1N/B/03
13 PKNM-13/1N/B/001 PKNM-13/1N/B/003 PKNM-13/1N/B/01 PKNM-13/1N/B/03
16 PKNM-16/1N/B/001 PKNM-16/1N/B/003 PKNM-16/1N/B/01 PKNM-16/1N/B/03
20 PKNM-20/1N/B/001 PKNM-20/1N/B/003 PKNM-20/1N/B/01 PKNM-20/1N/B/03
25 – PKNM-25/1N/B/003 PKNM-25/1N/B/01 PKNM-25/1N/B/03
32 – PKNM-32/1N/B/003 PKNM-32/1N/B/01 PKNM-32/1N/B/03
40 – PKNM-40/1N/B/003 PKNM-40/1N/B/01 PKNM-40/1N/B/03
RCBOs · 1+N Pole · C Curve standard AC
Tripping CurrentRated Current In (A) 10 mA 30 mA 100 mA 300 mA
2 PKNM-2/1N/C/001 PKNM-2/1N/C/003 PKNM-2/1N/C/01 PKNM-2/1N/C/03
4 PKNM-4/1N/C/001 PKNM-4/1N/C/003 PKNM-4/1N/C/01 PKNM-4/1N/C/03
6 PKNM-6/1N/C/001 PKNM-6/1N/C/003 PKNM-6/1N/C/01 PKNM-6/1N/C/03
10 PKNM-10/1N/C/001 PKNM-10/1N/C/003 PKNM-10/1N/C/01 PKNM-10/1N/C/03
13 PKNM-13/1N/C/001 PKNM-13/1N/C/003 PKNM-13/1N/C/01 PKNM-13/1N/C/03
16 PKNM-16/1N/C/001 PKNM-16/1N/C/003 PKNM-16/1N/C/01 PKNM-16/1N/C/03
20 PKNM-20/1N/C/001 PKNM-20/1N/C/003 PKNM-20/1N/C/01 PKNM-20/1N/C/03
25 – PKNM-25/1N/C/003 PKNM-25/1N/C/01 PKNM-25/1N/C/03
32 – PKNM-32/1N/C/003 PKNM-32/1N/C/01 PKNM-32/1N/C/03
40 – PKNM-40/1N/C/003 PKNM-40/1N/C/01 PKNM-40/1N/C/03
RCBOs · 1+N Pole · Type A · B Curvesensitive to residual pulsating DC
Tripping CurrentRated Current In (A) 10 mA 30 mA 100 mA 300 mA
2 PKNM-2/1N/B/001-A PKNM-2/1N/B/003-A PKNM-2/1N/B/01-A PKNM-2/1N/B/03-A
4 PKNM-4/1N/B/001-A PKNM-4/1N/B/003-A PKNM-4/1N/B/01-A PKNM-4/1N/B/03-A
6 PKNM-6/1N/B/001-A PKNM-6/1N/B/003-A PKNM-6/1N/B/01-A PKNM-6/1N/B/03-A
10 PKNM-10/1N/B/001-A PKNM-10/1N/B/003-A PKNM-10/1N/B/01-A PKNM-10/1N/B/03-A
13 PKNM-13/1N/B/001-A PKNM-13/1N/B/003-A PKNM-13/1N/B/01-A PKNM-13/1N/B/03-A
16 PKNM-16/1N/B/001-A PKNM-16/1N/B/003-A PKNM-16/1N/B/01-A PKNM-16/1N/B/03-A
25 PKNM-20/1N/B/001-A PKNM-20/1N/B/003-A PKNM-20/1N/B/01-A PKNM-20/1N/B/03-A
25 – PKNM-25/1N/B/003-A PKNM-25/1N/B/01-A PKNM-25/1N/B/03-A
32 – PKNM-32/1N/B/003-A PKNM-32/1N/B/01-A PKNM-32/1N/B/03-A
40 – PKNM-40/1N/B/003-A PKNM-40/1N/B/01-A PKNM-40/1N/B/03-A
100
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Com
bine
d RC
D/M
CBs
(RCB
Os)
101
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Com
bine
d RC
D/M
CBs
(RCB
Os)
Combined RCD/MCBs (RCBOs)Double Module
RCBOs · 1+N Pole · Type A · C Curvesensitive to residual pulsating DC
Tripping CurrentRated Current In (A) 10 mA 30 mA 100 mA 300 mA
2 PKNM-2/1N/C/001-A PKNM-2/1N/C/003-A PKNM-2/1N/C/01-A PKNM-2/1N/C/03-A
4 PKNM-4/1N/C/001-A PKNM-4/1N/C/003-A PKNM-4/1N/C/01-A PKNM-4/1N/C/03-A
6 PKNM-6/1N/C/001-A PKNM-6/1N/C/003-A PKNM-6/1N/C/01-A PKNM-6/1N/C/03-A
10 PKNM-10/1N/C/001-A PKNM-10/1N/C/003-A PKNM-10/1N/C/01-A PKNM-10/1N/C/03-A
13 PKNM-13/1N/C/001-A PKNM-13/1N/C/003-A PKNM-13/1N/C/01-A PKNM-13/1N/C/03-A
16 PKNM-16/1N/C/001-A PKNM-16/1N/C/003-A PKNM-16/1N/C/01-A PKNM-16/1N/C/03-A
20 – PKNM-20/1N/C/003-A PKNM-20/1N/C/01-A PKNM-20/1N/C/03-A
25 – PKNM-25/1N/C/003-A PKNM-25/1N/C/01-A PKNM-25/1N/C/03-A
32 – PKNM-32/1N/C/003-A PKNM-32/1N/C/01-A PKNM-32/1N/C/03-A
40 – PKNM-40/1N/C/003-A PKNM-40/1N/C/01-A PKNM-40/1N/C/03-A
RCBOs · 1+N Pole · Type G · B Curvesurge current-proof 3 kA, time delay
Tripping CurrentRated Current In (A) 10 mA 30 mA 100 mA 300 mA
13 – PKNM-13/1N/B/003-G – PKNM-13/1N/B/03-G
16 – PKNM-16/1N/B/003-G – PKNM-16/1N/B/03-G
20 – PKNM-25/1N/B/003-G – PKNM-25/1N/B/03-G
25 – PKNM-20/1N/B/003-G – PKNM-20/1N/B/03-G
32 – PKNM-32/1N/B/003-G – PKNM-32/1N/B/03-G
40 – PKNM-40/1N/B/003-G – PKNM-40/1N/B/03-G
RCBOs · 1+N Pole · Type G · C Curvesurge current-proof 3 kA, time delay
Tripping CurrentRated Current In (A) 10 mA 30 mA 100 mA 300 mA
13 – PKNM-13/1N/C/003-G – PKNM-13/1N/C/03-G
16 – PKNM-16/1N/C/003-G – PKNM-16/1N/C/03-G
20 – PKNM-20/1N/C/003-G – PKNM-20/1N/C/03-G
25 – PKNM-25/1N/C/003-G – PKNM-25/1N/C/03-G
32 – PKNM-32/1N/C/003-G – PKNM-32/1N/C/03-G
40 – PKNM-40/1N/C/003-G – PKNM-40/1N/C/03-G
100
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Com
bine
d RC
D/M
CBs
(RCB
Os)
101
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Com
bine
d RC
D/M
CBs
(RCB
Os)
Shunt Trip · for PKNMOperational Voltage
AC (V)Operational Voltage
DC (V) Part Number
110–415 110–220 ZP-ASA230
12–110 12–60 ZP-ASA24
Switch Interlockfor padlockable facility
Description Part Number
Toggle attachment for padlock IS/SPE-1TE
Note Padlock not supplied.
Combined RCD/MCBs (RCBOs)Double Module Accessories
Auxiliary Contacts
Contact Function Rated Current Ith(A)
Rated Voltage AC(V)
Minimum Current (mA DC) Part Number
1 N/O + 1 N/C 6 250 10 ZP-IHK
1 C/O 6 250 10 ZP-WHK
2 C/O 6 250 10 ZP-NHK
Note 2 x WHK auxiliary or 2 x IHK auxiliary contacts can be added together.1 contact on NHK auxiliary can be configured as trip signal indicator.
Trip Modulefor remote tripping of PKNM
Description Rated Tripping Current(A) Rated Voltage Part Number
Trip module with 1 N/O + 1Ω 0.1–0.3 230(400) V AC Z-KAM
102
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Com
bine
d RC
D/M
CBs
(RCB
Os)
103
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
Bs a
nd D
isco
nnec
ts
Combined RCD/MCBs (RCBOs)Technical Data
Combined RCD/MCB Devices (RCBOs) · PKS6
Specifications
RCD IEC EN 61009
Electrical
Current ratings 6 A to 40 ARated voltage 240 V AC, 1-PoleRated tripping currents 10, 30, 100, 300 mATripping types InstantaneousSensitivity ACCharacteristics B, C, DEndurance electrical ≥ 4,000 operating cycles mechanical ≥ 20,000 operating cycles
Mechanical
Frame size 45 mmDevice height 120 mmDevice width 17.5 mmDIN rail mountable on symmetrical DIN railTerminal capacity 1–25 mm2
Positive contact indication (red – green) in accordance with BS 7671
Combined RCD/MCB Devices (RCBOs) · PKNM
Specifications
RCD IEC EN 61009Type G acc. to ÖVE E 8601
Electrical
Current ratings 2 A to 40 ARated voltage 240 V AC, 1-Pole + NeutralRated tripping currents 10, 30, 100, 300 mATripping types Instantaneous Type G 10 ms delaySensitivity AC and Pulsating DCCharacteristics B, CEndurance electrical ≥ 4,000 operating cycles mechanical ≥ 20,000 operating cycles
Mechanical
Frame size 45 mmDevice height 80 mmDevice width 35 mmDIN rail mountable on symmetrical DIN railTerminal capacity 1–25 mm2 Positive contact indication (red – green) in accordance with BS 7671
Type Data
Type -G High reliability against unwanted tripping. Compulsory for any circuit where personal injury or damage to property may occur in case of unwanted tripping (ÖVE/ÖNORM E 8001-1 § 12.1.6).
Dimensions (mm)
PKS6
Dimensions (mm)
PKNM
35
80 45
9,5
30,5
44
60
5,5 4,5
T
102
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Com
bine
d RC
D/M
CBs
(RCB
Os)
103
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
Bs a
nd D
isco
nnec
ts
MCCBs and DisconnectsIntroduction
MCCBs and DisconnectsMoeller’s LZM1, 2, 3 & 4 moulded case circuit breakers and PN & N main switches have a uniquely uniform approach to mounting, operation and switching, with accessories designed to save time and money. Available in four frame sizes, with toggle or rotary handle operations, the LZM1-4 are suitable for a wide variety of applications.
104
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
Bs a
nd D
isco
nnec
ts105
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
Bs a
nd D
isco
nnec
ts
MCCBs · 3-Pole · 25 kA @ 415 V ACAC23 415 VCurrent (A)
Overload ReleaseIr (A)
Short-circuit Release Non-delayed Ir (A) Part Number
20 15–20 320–400 LZMB1-A20
25 20–25 300–500 LZMB1-A25
32 25–32 380–630 LZMB1-A32
40 32–40 320–400 LZMB1-A40
50 40–50 300–500 LZMB1-A50
63 50–63 380–630 LZMB1-A63
80 63–80 480–800 LZMB1-A80
100 80–100 600–1000 LZMB1-A100
125 100–125 750–1250 LZMB1-A125
160 125–160 1280 LZMB1-A160
Switch Disconnects · 3-Pole · 25 kA @ 415 V ACAC23 415 VCurrent (A)
Short-circuit Protection Max Fuse (A) gL Part Number
63 125 PN1-63
100 125 PN1-100
125 125 PN1-125
160 160 PN1-160
Auxiliary Contacts
Description Part Number
Internal fixing N/O auxiliary contact M22-K10
Internal fixing N/C auxiliary contact M22-K01
2 x early-make contacts NZM1-XHIV
Undervoltage Release
Description Voltage (V AC) Part Number
Undervoltage release 24 NZM1-XU24AC
240 NZM1-XU208-240AC
440 NZM1-XU380-440AC
Undervoltage release with2 x early-make auxiliary contacts
24 NZM1-XUHIV24AC
240 NZM1-XUHIV208-240AC
440 NZM1-XUHIV380-440AC
Shunt Trip
Description Voltage (V AC/DC) Part Number
Shunt trip 24 NZM1-XA24AC/DC
250 NZM1-XA208-250AC/DC
440 NZM1-XA380-440AC/DC
Shunt trip with2 x early-make auxiliary contacts
24 NZM1-XAHIV24AC/DC
250 NZM1-XAHIV208-250AC/DC
440 NZM1-XAHIV380-440AC/DC
MCCBs and Disconnects25 kA range · up to 160 A
104
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
Bs a
nd D
isco
nnec
ts
105
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
Bs a
nd D
isco
nnec
ts
Residual Current Relay
Description Part Number
30 mA residual current relay PFR-003
300 mA residual current relay PFR-03
0.3 A to 5 A residual current relay PFR-5
Core Balance Transformerused with residual current relay
Max rated current (A) DiameterPart NumberDistribution Motor Transformer max cable
50 50 20 13 PFR-W-20
150 100 30 20 PFR-W-30
150 100 35 23 PFR-W-35
400 200 70 47 PFR-W-70
Rotary Drives with Handles
Description Part Number
Direct mount Black handle with Rotary drive non lockable NZM1-XD
Direct mount Black handle with Rotary drive, shaft padlockable Off only NZM1-XDV
Direct mount Red/Yellow handle with Rotary drive lockable NZM1-XDVR
Door mount Black handle with Rotary drive non door interlocked NZM1-XTD
Door Interlocked Black handle with Rotary drive shaft padlockable NZM1-XTVD
Door Interlocked Red/Yelllow handle with Rotary drive shaft padlockable NZM1-XTVDVR
Extension Shafts
Description Part Number
Extension shaft for 400 mm mounting depth NZM1/2-XV4
Extension shaft for 600 mm mounting depth NZM1/2-XV6
Accessories
Description Part Number
Insulated black insert for door cut outs for MCCB lever and handle NXM1-XBR
Toggle lever locking device for Off position up to 3 padlocks NZM1-XKAV
Spacers for hight adjustment of MCCB – 17.5 mm NZM1/2-XAB
DIN rail clip for mounting MCCB to DIN rail NZM1-XC35
Set of 3 Box Terminals for MCCB NZM1-XKC
Additional terminal for bolt connection on MCCB NZM1-XKS
Terminal cover for 3-pole NZM1-XKSA
Rear connection kit for MCCB – set of 3 NZM2-XKR
MCCBs and Disconnects25 kA range Accessories
106
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
Bs a
nd D
isco
nnec
ts107
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
Bs a
nd D
isco
nnec
ts
MCCBs · 3-Pole · 25 kA @ 415 V ACAC23 415V Current
(A)Overload Release
Ir (A)Short-circuit Release Non-delayed Ir (A) Part Number
20 15–20 350 LZMB2-A20
25 20–25 350 LZMB2-A25
32 25–32 350 LZMB2-A32
40 32–40 320–400 LZMB2-A40
50 40–50 300–500 LZMB2-A50
63 50–63 380–630 LZMB2-A63
80 63–80 480–800 LZMB2-A80
100 80–100 600–1000 LZMB2-A100
125 100–125 750–1250 LZMB2-A125
160 125–160 960–1600 LZMB2-A160
200 160–200 1200–2000 LZMB2-A200
250 200–250 1500–2500 LZMB2-A250
Switch Disconnects · 3-Pole · 25 kA @ 415 V ACAC23 415 V Current
(A)Short-circuit Protection
Max Fuse (A) gL Part Number
160 250 PN2-160
200 250 PN2-200
250 250 PN2-250
Auxiliary Contacts
Description Part Number
Internal fixing N/O auxiliary contact M22-K10
Internal fixing N/C auxiliary contact M22-K01
2 x early-make contacts NZM2/3-XHIV
Undervoltage Release
Description Voltage (V AC) Part Number
Undervoltage release 24 NZM2/3-XU24AC
240 NZM2/3-XU208-240AC
440 NZM2/3-XU380-440AC
Undervoltage release with2 x early-make auxiliary contacts
24 NZM2/3-XUHIV24AC
240 NZM2/3-XUHIV208-240AC
440 NZM2/3-XUHIV380-440AC
Shunt Trip
Description Voltage (V AC/DC) Part Number
Shunt trip 24 NZM2/3-XA24AC/DC
250 NZM2/3-XA208-250AC/DC
440 NZM2/3-XA380-440AC/DC
Shunt trip with2 x early-make auxiliary contacts
24 NZM2/3-XAHIV24AC/DC
250 NZM2/3-XAHIV208-250AC/DC
440 NZM2/3-XAHIV380-440AC/DC
MCCBs and Disconnects25 kA range · up to 250 A
106
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
Bs a
nd D
isco
nnec
ts
107
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
Bs a
nd D
isco
nnec
ts
Core Balance Transformer · used with residual current relay
Max rated current (A) DiameterPart NumberDistribution Motor Transformer Max Cable
50 50 20 13 PFR-W-20
150 100 30 20 PFR-W-30
150 100 35 23 PFR-W-35
400 200 70 47 PFR-W-70
Remote Drive Operator · for NZM2 On and Off switching
Description Part Number
48–60 V AC 50/60 Hz NZM2-XR48-60AC
208–240 V AC 50/60 Hz NZM2-XR110-130AC
380–440 V AC 50/60 Hz NZM2-XR208-240AC
24–30 V DC NZM2-XR24-30DC
Rotary Drives with handles
Description Part Number
Direct mount Black handle with Rotary drive non lockable NZM2-XD
Direct mount Black handle with Rotary drive, shaft padlockable Off only NZM2-XDV
Direct mount Red/Yellow handle with Rotary drive lockable NZM2-XDVR
Door mount Black handle with Rotary drive non door interlocked NZM2-XTD
Door Interlocked Black handle with Rotary drive shaft padlockable NZM2-XTVD
Door Interlocked Red/Yelllow handle with Rotary drive shaft padlockable NZM2-XTVDVR
Extension Shafts
Description Part Number
Extension shaft for 400 mm mounting depth NZM1/2-XV4
Extension shaft for 600 mm mounting depth NZM1/2-XV6
Accessories
Description Part Number
Insulated black insert for door cut outs for MCCB lever and handle NXM2-XBR
Toggle lever locking device for off position up to 3 padlocks NZM2/3-XKAV
Spacers for hight adjustment of MCCB – 17.5 mm NZM1/2-XAB
DIN rail clip for mounting MCCB to DIN rail NZM2-XC75
Set of 3 Box terminals for MCCB NZM2-160-XKC
Set of 3 Box terminals for MCCB NZM2-250-XKC
Additional terminal for bolt connection on MCCB NZM2-XKS
Terminal cover for 3-pole NZM2-XKSA
Rear connection kit for MCCB set of 3 NZM2-XKR
MCCBs and Disconnects25 kA range · Accessories
Residual Current Relay
Description Part Number
30 mA residual current relay PFR-003
300 mA residual current relay PFR-03
0.3 A to 5 A residual current relay PFR-5
108
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
Bs a
nd D
isco
nnec
ts109
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
Bs a
nd D
isco
nnec
ts
MCCBs · 3-Pole · 50 kA @ 415 V ACAC23 415V Current
(A)Overload Release
Ir (A)Short-circuit Release Non-delayed Ir (A) Part Number
250 200–250 1500–2500 LZMN3-A250
320 250–320 1920–3200 LZMN3-A320
400 320–400 2400–4000 LZMN3-A400
500 200–400 3000–5000 LZMN3-A500
630 500–630 3750–6300 LZMN3-A630
400 320–400 2400–4000 LZMN3-4-A400
630 500–630 3750–6300 LZMN3-4-A630
Switch Disconnects · 3-Pole · 50 kA @ 415 V ACAC23 415 V Current
(A)Short-circuit Protection
Max Fuse (A) gL Part Number
250 630 PN3-250
400 630 PN3-400
630 2 x 800 PN3-630
Auxiliary Contacts
Description Part Number
Internal fixing N/O auxiliary contact M22-K10
Internal fixing N/C auxiliary contact M22-K01
2 x early-make contacts NZM2/3-XHIV
Undervoltage Release
Description Voltage (V AC) Part Number
Undervoltage release 24 NZM2/3-XU24AC
240 NZM2/3-XU208-240AC
440 NZM2/3-XU380-440AC
Undervoltage release with2 x early-make auxiliary contacts
24 NZM2/3-XUHIV24AC
240 NZM2/3-XUHIV208-240AC
440 NZM2/3-XUHIV380-440AC
Shunt Trip
Description Voltage (V AC/DC) Part Number
Shunt trip 24 NZM2/3-XA24AC/DC
250 NZM2/3-XA208-250AC/DC
440 NZM2/3-XA380-440AC/DC
Shunt trip with2 x early-make auxiliary contacts
24 NZM2/3-XAHIV24AC/DC
250 NZM2/3-XAHIV208-250AC/DC
440 NZM2/3-XAHIV380-440AC/DC
Residual Current Relay
Description Part Number
30 mA residual current relay PFR-003
300 mA residual current relay PFR-03
0.3 A to 5 A residual current relay PFR-5
MCCBs and Disconnects50 kA range · up to 630 A
D1
D2
C1
C2
108
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
Bs a
nd D
isco
nnec
ts
109
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
Bs a
nd D
isco
nnec
ts
Core Balance Transformerused with residual current relay
Max Rated Current (A) DiameterPart NumberDistribution Motor Transformer Max cable
150 100 35 23 PFR-W-35
400 200 70 47 PFR-W-70
600 250 105 70 PFR-W-105
1200 630 140 93 PFR-W-140
1800 800 210 140 PFR-W-210
Remote Drive Operatorfor NZM2 ON and OFF switching
Description Part Number
48–60 V AC 50/60 Hz NZM3-XR48-60AC
208–240 V AC 50/60 Hz NZM3-XR110-130AC
380–440 V AC 50/60 Hz NZM3-XR208-240AC
24–30 V DC NZM3-XR24-30DC
Rotary Drives with Handles
Description Part Number
Direct mount Black handle with Rotary drive non lockable NZM3-XD
Direct mount Black handle with Rotary drive, shaft padlockable Off only NZM3-XDV
Direct mount Red/Yellow handle with Rotary drive lockable NZM3-XDVR
Door mount Black handle with Rotary drive non door interlocked NZM3-XTD
Door Interlocked Black handle with Rotary drive shaft padlockable NZM3-XTVD
Door Interlocked Red/Yelllow handle with Rotary drive shaft padlockable NZM3-XTVDVR
Extension Shafts
Description Part Number
Extension shaft for 400 mm mounting depth NZM3/4-XV4
Extension shaft for 600 mm mounting depth NZM3/4-XV6
Accessories
Description Part Number
Insulated black insert for door cut outs for MCCB lever and handle NXM3-XBR
Toggle lever locking device for off position up to 3 padlocks NZM2/3-XKAV
Spacers for hight adjustment of MCCB · 17.5 mm NZM3-XAB
Set of 3 Box terminals for MCCB · 500 A In max NZM3-XKC
Set of 3 Box terminals for MCCB · 630 A In max NZM3-4-XKC
Additional terminal for bolt connection on MCCB NZM3-XKS
Terminal cover for 3-pole NZM3-XKSA
Rear connection kit for MCCB set of 3 · 630A In Max NZM3-XKR
MCCBs and Disconnects50 kA range Accessories
110
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
Bs a
nd D
isco
nnec
ts111
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
Bs a
nd D
isco
nnec
ts
MCCBs · 3 & 4 Pole · 50 kA @ 415 V AC
Number of Poles AC23 415V Current(A)
Overload ReleaseIr (A)
Short-circuit Release Non-delayed Ir (A) Part Number
3 800 400–800 1600–9600 LZMN4-A800
4 800 400–800 1600–9600 LZMN4-4-A800
Switch Disconnects · 3 & 4 Pole · 50 kA @ 415 V AC
Number of Poles AC23 415 V Current(A)
Short-circuit Protection Max Fuse (A) gL Part Number
3 800 2 x 800 N4-800
4 800 2 x 800 N4-4-800
Auxiliary Contacts
Description Part Number
Internal fixing Normally Open auxiliary contact M22-K10
Internal fixing Normally Closed auxiliary contact M22-K01
2 x early-make contacts NZM4-XHIV
Undervoltage Release
Voltage (V AC) Part Number
24 NZM4-XU24AC
110–130 NZM4-XU110-130AC
208–250 NZM4-XU208-250AC
380–440 NZM4-XU380-440AC
Shunt Trip
Voltage (V AC/DC) Part Number
24 NZM4-XA24AC/DC
110–130 NZM4-XA110-130AC/DC
208–250 NZM4-XA208-250AC/DC
380–440 NZM4-XA380-440AC/DC
Residual Current Relay
Description Part Number
30 mA residual current relay PFR-003
300 mA residual current relay PFR-03
0.3 A to 5 A residual current relay PFR-5
MCCBs and Disconnects50 kA range · up to 800 A
D1
D2
C1
C2
110
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
Bs a
nd D
isco
nnec
ts
111
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
Bs a
nd D
isco
nnec
ts
Core Balance Transformerused with residual current relay
Max Rated Current (A) DiameterPart NumberDistribution Motor Transformer Max cable
600 250 105 70 PFR-W-105
1200 630 140 93 PFR-W-140
1800 800 210 140 PFR-W-210
Remote Drive Operatorfor NZM2 On and Off switching
Description Part Number
48–60 V AC 50/60 Hz NZM4-XR48-60AC
208–240 V AC 50/60 Hz NZM4-XR110-130AC
380–440 V AC 50/60 Hz NZM4-XR208-240AC
24–30 V DC NZM4-XR24-30DC
Rotary Drives with Handles
Description Part Number
Direct mount Black handle with Rotary drive non-lockable NZM4-XD
Direct mount Black handle with Rotary drive, shaft padlockable Off only NZM4-XDV
Direct mount Red/Yellow handle with Rotary drive lockable NZM4-XDVR
Door mount Black handle with Rotary drive non door interlocked NZM4-XTD
Door Interlocked Black handle with Rotary drive shaft padlockable NZM4-XTVD
Door Interlocked Red/Yelllow handle with Rotary drive shaft padlockable NZM4-XTVDVR
Extension Shafts
Description Part Number
Extension shaft for 400 mm mounting depth NZM3/4-XV4
Extension shaft for 600 mm mounting depth NZM3/4-XV6
Accessories
Description Part Number
Insulated black insert for door cut outs for MCCB lever and handle NXM4-XBR
Terminal cover for 3-pole NZM4-XKSA
Phase isolator plates NZM4-XKP
MCCBs and Disconnects50 kA range Accessories
112
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
Bs a
nd D
isco
nnec
ts113
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Cont
rol a
nd S
wit
chin
g
MCCBs and DisconnectsTechnical Data
Moulded Case Circuit Breakers (MCCBs) · LZMB LZMN PN N• Protection of electric circuits against overload and short-circuit.• Adjustable thermal as well as the short-circuit release.• With the circuit breaker in reverse connection, its rated ultimate short-circuit breaking capacity remains unchanged.• No derating up to +50°C.• Mounting: vertical position, may be turned by 90° in every axis.• Ease of mounting all circuit breakers into the same mounting depth using spacer (in steps of 17.5 mm).• Design according to EN 60947-2 standard.• PN switch disconnectors have the same design as the LZM breakers.
Technical DataLZMB1 / PN LZMB2 / PN2 LZMN3 / PN3 LZMN4 / N4
Electrical
Rated current In 20–165 A / 63–160 A 160–250 A 250–630 A 800 AMaximum operating voltage 440 V AC 440 V AC 690 V AC 690 V ACOvervoltage category III/3 III/3 III/3 III/3Rated impulse withstand voltage Uimp 6 kV 8 kV 8 kV 8 kVAdjustment range for circuit breaker thermal release 0.8–1 x In 0.8–1 x In 0.5–1 x In 0.5–1 x InAdjustment range for circuit breaker short-circuit release 6–10 x In 6–10 x In LZM3-250/400: 2–11 x In
LZM3-630: 2–8 x In2–10 x In
40 A: 8–10 x InRated ultimate short-circuit breaking capacity Icu
(240 V) 30 kA 30 kA 85 kA 50 kA (415 V) 25 kA 25 kA 50 kA 50 kARated service short-circuit breaking capacity Ics
(240 V) 30 kA 30 kA 85 kA 37 kA (415 V) 25 kA 25 kA 50 kA 37 kAEndurance mechanical 20,000 operating cycles 20,000 operating cycles 15,000 operating cycles 15,000 operating cycles electrical (AC-1) 10,000 operating cycles 10,000 operating cycles 5,000 operating cycles 5,000 operating cycles (400–415 V) (AC-3) 7,500 operating cycles 6,500 operating cycles 2,000 operating cycles 2,000 operating cycles
Mechanical
Cover plate cut-out height 45 mm 95 mm 95 mm 95 mmConnecting terminals Clamp type M8 Bolt M10 Bolt M10 BoltTerminal capacity (Cu) solid cable 1 x 2.5–16 mm2
2 x 2.5–16 mm21 x 2.5–16 mm2
2 x 2.5–16 mm22 x 16 mm2
stranded cable 1 x 25–70 mm2
2 x 25 mm21 x 25–185 mm2
2 x 25–70 mm21 x 25–240 mm2
2 x 25–240 mm24 x 50–240 mm2
Ambient temperature range -25 to +70°C -25 to +70°C -25 to +70°C -25 to +70°CMounting Direct to back plate, screws provided 4 x M4 4 x M4 4 x M5 4 x M5 or DIN rail using NZM1-XC35 NZM1-XC35
112
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
MCC
Bs a
nd D
isco
nnec
ts
113
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Cont
rol a
nd S
wit
chin
g
Control and SwitchingMoeller’s comprehensive range of easy-to-use DIN rail mounted automation and control devices can be utilised with our range of consumer units, distribution boards and panel boards. The range includes components such as timers, counters, programmable relays, contactors, and automatic reset devices used in conjunction with RCDs.
To complement our range of DIN rail mounted components we have a range of comb busbar to ensure speed and ease of connection, and a range of fuse holders that will fi t into our consumer units, distribution boards and modular service boxes – see page 130.
Control and SwitchingIntroduction
Main Load Disconnector Switch ( Isolator) · 10 kA
Rated Current In (A) Single-Pole Double-Pole Triple-Pole Four-Pole
16 IS/16/1 IS/16/2 IS/16/3 IS/16/4
20 IS/20/1 IS/20/2 IS/20/3 IS/20/4
25 IS/25/1 IS/25/2 IS/25/3 IS/25/4
32 IS/32/1 IS/32/2 IS/32/3 IS/32/4
40 IS/40/1 IS/40/2 IS/40/3 IS/40/4
63 IS/63/1 IS/63/2 IS/63/3 IS/63/4
80 IS/80/1 IS/80/2 IS/80/3 IS/80/4
100 IS/100/1 IS/100/2 IS/100/3 IS/100/4
125 IS/125/1 IS/125/2 IS/125/3 IS/125/4
Accessories
Description Part Number
Switching interlock (without lock) IS/SPE-1TE
Terminal cover Z-IS/AK-1TE
114
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Cont
rol a
nd S
wit
chin
g115
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Cont
rol a
nd S
wit
chin
g
Control and Switching
Installation Relays
Control Voltage Rated Current AC1 (A) Contacts Module Width Part Number
230 V AC 20 1 N/O 1 Z-RE230/S
20 2 N/O 1 Z-RE230/SS
20 1 N/O + 1 N/C 1 Z-RE230/SO
24 V AC 20 2 N/O 1 Z-RE24/SS
20 1 N/O + 1 N/C 1 Z-RE24/SO
24 V DC 20 2 N/O + 2 N/C 2 Z-RE23/2S20
Installation Contactors
Control Voltage Rated Current AC1 (A) Contacts Module Width Part Number
230 V AC 25 4 N/O 2 Z-SCH230/25-40
4 N/C 2 Z-SCH230/25-04
3 N/O + 1 N/C 2 Z-SCH230/25-31
2 N/O + 2 N/C 2 Z-SCH230/25-22
40 4 N/O 4 Z-SCH230/40-40
3 N/O + 1 N/C 4 Z-SCH230/40-31
2 N/O + 2 N/C 4 Z-SCH230/40-22
2 N/O 4 Z-SCH230/40-20
63 4 N/O 4 Z-SCH230/63-40
3 N/O + 1 N/C 4 Z-SCH230/63-31
2 N/O + 2 N/C 4 Z-SCH230/63-22
2 N/O 4 Z-SCH230/63-20
24 V AC 25 4 N/O 2 Z-SCH24/25-40
2 N/O + 2 N/C 2 Z-SCH24/25-22
Light Intensity Switch
Function Rated Current AC1 (A) Contacts Module Width Part Number
DIN rail mount 16 1 N/O 1 DS-GS/1S
DIN rail mount 16 1 C/O + Timer 3 DS-GS/1W
Outdoor installation 10 1 N/O – DS-GK
Spare sensor for DS–DG – – – Z-DS/SENSOR
Cap for daylight 100–10,000 lux – – – Z-DS/KAPPE
Staircase Switch
Function Rated Current AC1 (A) Contacts Module Width Part Number
with stop function 16 1 C/O 1 TLE
stop & alarm function 16 1 C/O 1 TLK
114
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Cont
rol a
nd S
wit
chin
g
115
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Cont
rol a
nd S
wit
chin
g
Control and Switching
Analogue Time Switch
Drive Program Contacts Chan/Mod Part Number
Synchronous Day 1 N/O 1/1 Z-SGS/TA
Day 1 C/O 1/3 SU-GS/1W-TA
Week 1 C/O 1/3 SU-GS/1W-WO
Quartz Day 1 N/O 1/1 SU-CQ-TA
Day 1 C/O 1/3 SU-CQ/1W-A
Week 1 C/O 1/3 SU-CQ/1W-WO
Day + Week 2 C/O 2/6 SU-CQ/2W-TW
Digital Time Switch
Drive Program Contacts Chan/Mod Part Number
Quartz Day 1 C/O 1/2 Z-SDM/1K-TA
Week 1 C/O 1/2 Z-SDM/1K-WO
Week 2 C/O 2/2 Z-SDM/2K-WO
Multifunction Timers
Description Contacts Operating Voltages(V AC/DC) Part Number
Delay on and off 1 C/O 24–240 ZRER/W
Delay on and off + input + pulse 1 C/O 24–240 ZRMF/W
Continuous interval timer 2 C/O 24–240 ZRTAK/WW
Delay on and off + input + pulse 2 C/O 24–240 ZRMF/WW
Signalling Devices
Function Voltage (V AC) Module Width Part Number
Buzzer 12 1 Z-SUM12
24 1 Z-SUM24
230 1 Z-SUM230
Bell 12 1 Z-GLO12
24 1 Z-GLO24
230 1 Z-GLO230
116
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Cont
rol a
nd S
wit
chin
g117
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
Control and Switching
Transformers · 230 V AC
Description SecondaryVoltage (V)
SecondaryCurrent (A) Module Width Part Number
Bell (8 VA) 8 1 2 TR-G/8
4–8–12 1–1–0.67 2 TR-G3/8
8 1 2 TR-G/8-S *
Bell (18 VA) 4–8–12 2–2–1.5 2 TR-G3/18
12–24 2–1 3 TR-G2/24
Note * TR-G/8-S has primary switch.
Automatic Re-closing Device
Description Relay Output Operating Voltages Part Number
230 V AC 5 x re-closing device 5 A / 250 V 220–240 V AC Z-FW-LP
24–48 V DC 5 x re-closing device 5 A / 250 V 24–48 V DC Z-FW-LPD
Add-on remote control module – 24–230 V AC/DC Z-FW-MO
Undervoltage Relay
Description Switching Voltage Un Operating Voltages Part Number
Single- and three-phase UV relay x 0.85 230/400 V AC Z-UR/400
Undervoltage Monitoring Relay
Description Switching Voltage Un Operating Voltages Part Number
5–15 minute time-delay UV relay x 0.85 230/400 V AC Z-ZRU/400
5–15 minute time-delay UV relay x 0.85 230/380 V AC Z-ZRU/380
116
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Cont
rol a
nd S
wit
chin
g
117
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
Surge ProtectionIntroduction · SPD Class B
Surge ProtectionElectrical surges are a danger to protective devices. Moeller’s range of surge protection devices provide three levels of protection against short circuits, overloads and transient overvoltages.Class B devices Distribution boards should be equipped with class B surge protective devices. This type of device will discharge most of the surge voltages entering your premises through overhead power lines or through the external lightning protection system into the ground.Class C devices Downstream of the distribution board (where the class B surge protective devices are installed) over-voltage will still get into your electric system, leaving many electric appliances vulnerable. By using a class C device a further reduction of overvoltage can be achieved.Class D devices The overvoltage remaining downstream of a class C protective device is still dangerous for many electrical appliances. Additional protection for sensitive or expensive equipment – such as hi-fi systems, computers, or TV sets – can be ensured by means of a class D protective device.
SPD Class B · Lightning Current Arresters · SPIMaximum Discharge
CurrentNominal Discharge
CurrentVoltage Protection
LevelMaximum Continuous
Operating Voltage Part Number
35 kA 35 kA < 1.5 kV 440 V AC SPI-35/440
50 kA 50 kA < 1.5 kV 260 V AC SPI-50/NPE
100 kA 100 kA < 1.5 kV 260 V AC SPI-100/NPE
SPD Class B · Lightning Current Arrester Sets · SPILightning Protection Classes I, II, III, IV
Description Poles Part Number
TN-C-Set 3 SPI-35/440/3
TN-S/TT-Set 3+1 SPI-3+1
118
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
119
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
SPD Class B+C · Lightning Current Arrester Sets · SPBLightning Protection Classes III, IV
Description Poles With Remote Indication Part Number
TN-S-Set 2 No SPB-12/280/2
TN-C-Set 3 No SPB-12/280/3
TN-S-Set 4 No SPB-12/280/4
TN-S/TT-Set 3 Yes SPB-1+1
TN-S/TT-Set 4 Yes SPB-3+1
SPD Class B+C · Auxiliary Switch · SPB
Description Rated CurrentAC12 @ 250 V AC
Minimum Volts per Contact Part Number
1 N/O + 1 N/C aux for SPB-12/280 2 A 24 V AC SPB-HK-W
SPD Class B+C · Lightning Current Arrester Sets · SP-B+CLightning Protection Classes I, II, III, IV
Description Poles Part Number
TN-C-Set 3 SP-B+C/3
TN-S/TT-Set 3+1 SP-B+C/3+1
Surge ProtectionSPD Class B+C
SPD Class B+C · Auxiliary Switch · SP-B+C
Description Rated Current AC12 @ 250 V AC
Minimum Volts per Contact Part Number
1 C/O aux for SPC-B+C 2 A 24 V AC SPC-S-HK
SPD Class B+C · Lightning Current Arrester – Surge Arrester · SPBMaximum Discharge
CurrentNominal Discharge
CurrentVoltage Protection
LevelMaximum Continuous
Operating Voltage Part Number
50 kA 25 kA < 1.5 kV 280 V AC SPB-12/280
100 kA 100 kA < 1.5 kV 255 V AC SPB-100/NPE
118
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
119
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
SPD Class C · Surge Arrester · SPC-Eprotection against transient overvoltage caused by indirect lightning strike and switching operations
Maximum Discharge Current (kA)
Nominal Discharge Current (kA)
Voltage Protection Level
Maximum Continuous Operating Voltage (VAC) Part Number
30 15 < 550 V 75 SPC-E-75
40 20 < 800 V 130 SPC-E-130
40 20 < 1.4 kV 280 SPC-E-280
40 20 < 1.6kV 335 SPC-E-335
40 20 < 1.8kV 385 SPC-E-385
40 20 < 2.2kV 460 SPC-E-460
40 20 < 2.6 kV 580 SPC-E-580
40 20 < 1.0 kV N–PE 260 SPC-E-N/PE
10 5 < 1.2 kV 280 SPC-EFN-280
SPD Class C · Auxiliary Switch · SPC-E
Description Rated current AC12 @ 250 V AC
Minimum Volts per Contact Part Number
1 C/O aux for SPC-E 2 A 24 V AC SPC-S-HK
SPD Class C · Transient Overvoltage · Plug-in Surge Arrester · SPC-SMaximum Discharge
Current (kA)Nominal Discharge
Current (kA)Voltage Protection
LevelMaximum Continuous
Operating Voltage (VAC) Part Number
30 15 < 550 V 75 SPC-S-15/75
40 20 < 800 V 130 SPC-S-20/130
40 20 < 1.0 kV 175 SPC-S-20/175
40 20 < 1.4 kV 280 SPC-S-20/280
40 20 < 1.6kV 335 SPC-S-20/335
40 20 < 1.8kV 385 SPC-S-20/385
40 20 < 2.2kV 460 SPC-S-20/460
40 20 < 2.6kV 580 SPC-S-20/580
40 30 < 1.0 kV N–PE 260 SPC-S-N/PE
SPD Class C · Base for Plug-in Surge Arrester · SPC-S
Description Poles Part Number
Plug-in base 1 SPC-S-S1
Plug-in base 1+1 (2-pole) SPC-S-S2-1+1
Plug-in base 2 SPC-S-S2
Plug-in base 3 SPC-S-S3
Plug-in base 4 SPC-S-S4
Plug-in base 3+1 (4-pole) SPC-S-S4-3+1
Surge ProtectionSPD Class C
120
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
121
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
SPD Class C · Transient Overvoltage · Base and Plug-in Surge Arrester · SPC-SMaximum Discharge
Current (kA)Nominal Discharge
Current (kA) Poles Maximum Continuous Operating Voltage (VAC) Part Number
40 1 x 20 1 130 SPC-S-20/130/1
40 1 x 20 1 175 SPC-S-20/175/1
40 2 x 20 2 175 SPC-S-20/175/2
40 1 x 20 1 280 SPC-S-20/280/1
40 2 x 20 2 280 SPC-S-20/280/2
40 3 x 20 3 280 SPC-S-20/280/3
40 4 x 20 4 280 SPC-S-20/280/4
40 1 x 20 1 335 SPC-S-20/335/1
40 2 x 20 2 335 SPC-S-20/335/2
40 3 x 20 3 335 SPC-S-20/335/3
40 4 x 20 4 335 SPC-S-20/335/4
40 1 x 20 1 385 SPC-S-20/385/1
40 2 x 20 2 385 SPC-S-20/385/2
40 3 x 20 3 385 SPC-S-20/385/3
40 4 x 20 4 385 SPC-S-20/385/4
40 1 x 20 1 460 SPC-S-20/460/1
40 2 x 20 2 460 SPC-S-20/460/2
40 3 x 20 3 460 SPC-S-20/460/3
40 4 x 20 4 460 SPC-S-20/460/4
40 1 x 20 1 580 SPC-S-20//580/1
40 1 x 20 1 + 1p – SPC-S-1+1
40 1 x 20 3 + 1p – SPC-S-3+1
SPD Class C · Auxiliary Switch · SPC-S
Description Rated Current AC12 @ 250 V AC
Rated Voltage per Contact Part Number
1 C/O aux for SPC-S 2 A 24 V AC SPC-S-HK
Surge ProtectionSPD Class C
120
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
121
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
Busbars · for SPI, SP-B+C
Number of Poles Rated Current @ 230/400 V Part Number
2 63 A Z-GV-U/2
3 63 A Z-GV-U/3
4 63 A Z-GV-U/4
5 63 A Z-GV-U/5
6 63 A Z-GV-U/6
7 63 A Z-GV-U/7
8 63 A Z-GV-U/8
9 63 A Z-GV-U/9
Busbars · for SPI, SPC
Number of Poles Rated Current @ 230/400 V Part Number
6 63 A Z-GV-16/3P-3TE/6
Note Must be cut to length in some cases.
Surge ProtectionAccessories
Lead-through Terminal · for SPI
Peak Impulse Current Rated Current @ 30 ˚C Rated Voltage Part Number
100 kA 125 A 500 V AC/DC SPB-D-125
Lead-through Terminal · for SPB, SPC
Rated Current @ 30 ˚C Rated Voltage Part Number
63 A 500 V AC/DC Z-D63
Busbars · for SPCNumber of
Module Units Rated Current @ 230/400 V Part Number
2 63 A ZV-KSBI-2TE
3 63 A ZV-KSBI-3TE
3 63 A ZV-KSBI-3TE/S
4 63 A ZV-KSBI-4TE
5 63 A ZV-KSBI-5TE
5 63 A ZV-KSBI-5TE/N
7 63 A ZV-KSBI-7TE
Marking Label · for SPI…, SPL-35, SPB-D-125
Description Part Number
White labels size 7x17 mm for use with surge arresters SPI-BZS-L/N/PE
122
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
123
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
SPD Class B · Lightning Current Arrester · SPI• Field of application: For the protection of low voltage distribution systems against direct lightning strike into the
overhead power supply line or external lightning protection system (IEC 61024-1, IEC 61312-1).• Application according to IEC 60364-5-53 Clause 534. • Test class I, in accordance with IEC 61643-1. • SPD-
type T1, in accordance with pr EN 61643-1.• Encapsulated version: during the discharge process, the device does not issue any hot ionised gases, therefore
there is no need for keeping a safety distance to flammable materials.
Technical Data
Electrical SPI-35/440 SPI-50/NPE SPI-100/NPE
Design Encapsulated Encapsulated EncapsulatedResponding time Tr < 100 ns < 100 ns < 100 nsVoltage protection level Up 1.5 kV 1.5 kV 1.5 kVMaximum continuous operating voltage Uc 440 V AC 260 V AC 260 V ACRated frequency 50/60 Hz 50/60 Hz 50/60 HzDischarge current (8/20) µs Imax/In 35 kA 50 kA 100 kAImpulse current Iimp (10/350) µs Peak current 35 kA 50 kA 100 kA Charge Q 17.5 As 25 As 50 As Specific energy 305 kJ/Ω 625 kJ/Ω 2500 kJ/ΩInsulation resistance RISO > 10 MΩ > 10 MΩ >1 0 MΩShort-circuit current quenching capability 3 kA rms / 260V 500 A rms / 260V 100 A rms / 260V without back-up fuse 1.5 kA rms / 440V – –Short-circuit current strength at max. back-up fuse 25 kA rms – –Maximum back-up fuse 125 A gL – –
Mechanical
Frame size 45 mm 45 mm 45 mmDevice height 90 mm 90 mm 90 mmDevice width 17.5 mm 17.5 mm 35 mmWeight 174 g 178 g 320 gUpper and lower lift terminal capacity solid 0.5–35 mm2 0.5–35 mm2 10–50 mm2
flexible 0.5–25 mm2 0.5–25 mm2 16–35 mm2
DIN rail mountable: on symmetrical DIN railPermitted relative air humidity < 95% < 95% < 95%Permitted ambient temperature -40°C to +85°C -40°C to +85°C -40°C to +85°C
SPD Class B+C · Lightning Current Arrester – Surge Arresters · SPB• Field of application: For the protection of low voltage distribution systems against transient overvoltage caused
by direct and indirect lightning strike and switching operations.• Application according to IEC 60364-5-53 Clause 534. • Test class I, II, III, in accordance with IEC 61643-1. •
SPD-type T1, T2 , T3 in accordance with EN 61643-11.• Lightning protection classes III and IV in accordance with IEC 61024-1
Technical Data
Electrical SPB-12/280/… SPB-100/NPE
Response time (rate of voltage rise 5 kV/µs) < 25 ns < 100 nsVoltage protection level Up < 1.5 kV < 1.5 kVMaximum continuous operating voltage Uc 280 V AC 255 V ACRated frequency 50/60 Hz 50/60 HzDischarge current (8/20) µs Imax/In 50 kA 100 kAImpulse current Iimp (10/350) µs Peak current 12.5 kA 100kA Charge Q 6.25 As 50 As Specific energy 39.1 kJ/Ω 2500 kJ/ΩMaximum short-circuit current 50 kA –Maximum back-up fuse 160 A gL/gG –
Mechanical
Frame size 45 mm 45 mmDevice height 80 mm 80 mmDevice width 17.5 mm 35 mmWeight 121 g 250 gUpper and lower lift terminal capacity 4–25 mm2 4–35 mm2
DIN rail mountable: on symmetrical DIN rail
Surge ProtectionTechnical Data
Dimensions (mm)
SPI-35/440, SPI-50/NPE
SPI-100/NPE
Dimensions (mm)
SPB-12/280/…
SPB-100/NPE
4580
30,5
6
44
60
4,5
17,5
5,5
SPB-12/280/...
4580
44
6035
SPB-100/NPE
90
4580
30,5
6
44
60
4,5
17,5
5,5
SPB-12/280/...
4580
44
6035
SPB-100/NPE
90
122
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
123
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
Surge ProtectionTechnical Data
SPD Class B+C · Lightning Current Arrester – Surge Arrester Sets · SP-B+CLightning protection classes I, II, III, IV• Field of application: For the protection of low voltage distribution systems against direct lightning strike into the overhead power supply line or external lightning
protection system (IEC 61024-1, IEC 61312-1) and against indirect lightning strike and switching operations.• Application according to IEC 60364-5-53 Clause 534. • Test class I and II in accordance with IEC 61643-1. • SPD-type T1 and T2 in accordance with pr EN 61643-1.• Encapsulated version: during the discharge process, the device does not issue any hot ionised gases, therefore there is no need for keeping a safety distance to flammable
materials.
Technical DataElectrical SP-B+C/3 SP-B+C/3+1
Design Encapsulated EncapsulatedResponding time Tr < 25 ns < 25 nsVoltage protection level Up < 1.5 kV < 1.5 kVMaximum continuous operating voltage Uc L–(PE)N / N–PE 440 V AC / – 440 V AC / 260 V ACRated frequency 50/60 Hz 50/60 HzDischarge current (8/20) µs Imax/In 3 x 35 kA 100 kAImpulse current Iimp (10/350) µs Peak current 100 kA 100 kA Charge Q 50 As 50 As Specific energy 2500 kJ/Ω 2500 kJ/ΩShort-circuit current quenching capability L–(PE)N / N–PE at 260 V 3 kA rms / 3 kA rms 3 kA rms / 100 A rms at 440 V 1.5 kA rms / 1.5 kA rms 1.5 kA rmsShort-circuit current strength at max. back-up fuse 25 kA rms 25 kA rmsMaximum back-up fuse 125 A gL 125 A gL
Mechanical
Frame size 45 mm 45 mmDevice height 90 mm 90 mmDevice width 110 mm 164 mmWeight 1100 g 1420 gUpper and lower lift terminal capacity solid L, N, PEN / PE 0.5–35 mm2 0.5–35 mm2 / 10–50 mm2
flexible L, N, PEN / PE 0.5–25 mm2 0.5–25 mm2 / 16–35 mm2
DIN rail mountable: on symmetrical DIN railPermitted relative air humidity < 95% < 95%Permitted ambient temperature -40°C to +70°C -40°C to +70°C
Dimensions (mm)
TN-C-System TT-, TN-S-System3 x 230/400 V AC(3 x 220/380 V AC)(3 x 240/415 V AC)
3 x 230/400 V AC(3 x 220/380 V AC)(3 x 240/415 V AC)
Lightning Current Arrester – Surge Arrester➀ …SPI-35/440➁ …SPI-100/NPE for protection class I, II, III, IV➂ …SPC-S/20/460/3
Lead-through Terminal➃ …SPB-D-125
Busbar➄ …Z-GV-U/6➅ …Z-GV-U/9➆ …Z-GV-16/3PE-3TE/6
124
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
125
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
Surge ProtectionTechnical Data
SPD Class C · Surge Arresters · SPC-E• Field of application: For the protection of low voltage distribution systems against transient overvoltage caused by indirect lightning strike and switching operations.• Test class according to IEC 61643-1+A1. • SPD-type according to EN 61643-1.• Busbars ZV-KSBI are available for all customary applications.• Suitable for busbar connection to all XtraCombinations switchgear.
Technical Data
Electrical SPC-E-75 SPC-E-180 SPC-E-280 SPC-E-335 SPC-E-385 SPC-E-460 SPC-E-580
Responding time Tr < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 nsVoltage protection level at nominal discharge current < 550 V < 800 V < 1.4kV < 1.6kV < 1.8kV < 2.2kV < 2.6kVVoltage protection level at 5 kA (8/20) µs 400 V 550 V 1000 V 1200 V 1350 V 1700 V 2000 VMaximum continuous operating voltage Uc 75 V AC 130 V AC 280 V AC 335 V AC 385 V AC 460 V AC 580 V ACRated frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 HzNominal discharge current (8/20) µs In 15 kA 20 kA 20 kA 20 kA 20 kA 20 kA 20 kA Charge Q at In 0.43 As 0.57 As 0.57 As 0.57 As 0.57 As 0.57 As 0.57 As Specific energy at In 3.2 kJ/Ω 5.7 kJ/Ω 5.7 kJ/Ω 5.7 kJ/Ω 5.7 kJ/Ω 5.7 kJ/Ω 5.7 kJ/ΩMaximum discharge current Imax 30 kA 40 kA 40 kA 40 kA 40 kA 40 kA 40 kAMaximum back-up fuse 125 A gL 125 A gL 125 A gL 125 A gL 125 A gL 125 A gL 125 A gLMaximum short-circuit current 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA
Mechanical
Frame size 45 mm 45 mm 45 mm 45 mm 45 mm 45 mm 45 mmDevice height 80 mm 80 mm 80 mm 80 mm 80 mm 80 mm 80 mmDevice width 17.5 mm 17.5 mm 17.5 mm 17.5 mm 17.5 mm 17.5 mm 17.5 mmWeight 97 g 97 g 97 g 97 g 97 g 97 g 97 gUpper and lower lift terminal capacity 4–25 mm2 4–25 mm2 4–25 mm2 4–25 mm2 4–25 mm2 4–25 mm2 4–25 mm2
DIN rail mountable: on symmetrical DIN rail
Electrical SPC-E-N/PE
Responding time Tr < 100 nsVoltage protection level at nominal discharge current < 1.0 kVMaximum continuous operating voltage Uc 260 V ACRated frequency 50/60 HzNominal discharge current (8/20) µs In 20 kA Charge Q at In 0.57 As Specific energy at In 5.7 kJ/ΩMaximum discharge current Imax 40 kAMaximum back-up fuse –Maximum short-circuit current –Short-circuit current quenching capability at Uc and In 100 A rms
Mechanical
Frame size 45 mmDevice height 80 mmDevice width 17.5 mmWeight 97 gUpper and lower lift terminal capacity 4–25 mm2
DIN rail mountable: on symmetrical DIN rail
Dimensions (mm)
SPC-E-…
124
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
125
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
Surge ProtectionTechnical Data
SPD Class C · Surge Arresters · SPC-EFN-280• Field of application: For the protection of low voltage distribution systems against transient overvoltage caused by indirect lightning strike and switching operations.• Test class II according to IEC 61643-1. • SPD-type T2 according to pr EN 61643-1.
Technical Data
Electrical SPC-EFN-280
Response time Tr < 100 nsVoltage protection level at nominal discharge current < 1200 VMaximum continuous operating voltage Uc 280 V ACRated frequency 50/60 HzNominal discharge current (8/20) µs In 5 kA Charge Q at In 0.14 As Specific energy at In 357 J/ΩMaximum discharge current Imax 10 kAMaximum back-up fuse not necessaryMaximum short-circuit current 80 kA rms
Mechanical
Frame size 45 mmDevice height 80 mmDevice width 35 mmWeight 148 gUpper and lower lift terminal capacity 4–35 mm2
DIN rail mountable: on symmetrical DIN railPermitted ambient temperature -40°C to +70°C
126
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
127
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
Surge ProtectionTechnical Data
SPD Class C · Plug-in Surge Arresters · SPC-S• Field of application: For the protection of low voltage distribution systems against transient overvoltage caused by indirect lightning strike and switching operations.• Test class II according to IEC 61643-1+A1. • SPD-type T2 according to EN 61643-11.
Technical Data
ElectricalSPC-S-15/75
SPC-S-20/130
SPC-S-20/175
SPC-S-20/280
SPC-S-20/335
SPC-S-20/385
SPC-S-20/460
SPC-S- 20/580
Responding time Tr < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 nsVoltage protection level at nominal discharge current < 550 V < 800 V < 1.0 kV < 1.4 kV < 1.6 kV < 1.8 kV < 2.2 kV < 2.6 kVVoltage protection level at 5 kA (8/20) µs 400 V 550 V 700 V 1000 V 1200 V 1350 V 1700 V 2000 VMaximum continuous operating voltage Uc 75 V AC 130 V AC 175 V AC 280 V AC 335 V AC 385 V AC 460 V AC 580 V ACRated frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 HzNominal discharge current (8/20) µs In 15 kA 20 kA 15 kA 20 kA 20 kA 20 kA 20 kA 20 kA Charge Q at In 0.43 As 0.57 As 0.57 As 0.57 As 0.57 As 0.57 As 0.57 As 0.57 As Specific energy at In 3.2 kJ/Ω 5.7 kJ/Ω 5.7 kJ/Ω 5.7 kJ/Ω 5.7 kJ/Ω 5.7 kJ/Ω 5.7 kJ/Ω 5.7 kJ/ΩMaximum discharge current Imax 30 kA 40 kA 40 kA 40 kA 40 kA 40 kA 40 kA 40 kA Maximum back-up fuse 160 A gL 160 A gL 160 A gL 160 A gL 160 A gL 160 A gL 160 A gL 160 A gLMaximum short-circuit current 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA
Mechanical
Frame size 45 mm 45 mm 45 mm 45 mm 45 mm 45 mm 45 mm 45 mmDevice height 80 mm 80 mm 80 mm 80 mm 80 mm 80 mm 80 mm 80 mmDevice width per pole 17.5 mm 17.5 mm 17.5 mm 17.5 mm 17.5 mm 17.5 mm 17.5 mm 17.5 mmWeight 110 g 110 g 110 g 110 g 110 g 110 g 110 g 110 gUpper and lower lift terminal capacity 4–25 mm2 4–25 mm2 4–25 mm2 4–25 mm2 4–25 mm2 4–25 mm2 4–25 mm2 4–25 mm2
DIN rail mountable: on symmetrical DIN railPermitted ambient temperature -40°C to
+70°C-40°C to +70°C
-40°C to +70°C
-40°C to +70°C
-40°C to +70°C
-40°C to +70°C
-40°C to +70°C
-40°C to +70°C
ElectricalSPC-S-N/PE
Response time Tr < 100 nsVoltage protection level at nominal discharge current < 1.0 kVMaximum continuous operating voltage Uc 260 V ACRated frequency 50/60 HzNominal discharge current (8/20) µs In 20 kA Charge Q at In 0.57 As Specific energy at In 5.7 kJ/ΩMaximum discharge current Imax 40 kA Short-circuit current quenching capability at Uc and InMaximum back-up fuse –Maximum short-circuit current –
Mechanical
Frame size 45 mmDevice height 80 mmDevice width per pole 17.5 mmWeight per pole 110 gUpper and lower lift terminal capacity 4–25 mm2
DIN rail mountable: on symmetrical DIN railPermitted ambient temperature -40°C to
+70°C
Dimensions (mm)
SPC-S-…
126
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
127
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
SPD Class C · Surge Arresters · SPC-S-1+1, SPC-S-3+1• Field of application: For the protection of low voltage distribution systems against transient overvoltage caused by indirect
lightning strike and switching operations.• Test class II according to IEC 61643-1+A1. • SPD-type T2 according to EN 61643-11.• Type SPC-S-3+1: consists of 1 base SPC-S-S4-3+1, 1 insert SPC-S-N/PE and 3 inserts SPC-S-20/335.• Type SPC-S-1+1: consists of 1 base SPC-S-S2-1+1, 1 insert SPC-S-N/PE and 1 insert SPC-S-20/335.
Technical Data
Electrical SPC-S-1+1 SPC-S-3+1
Response time Tr L–N / N–PE / L–PE <25 ns / <100 ns / <100 ns <25 ns / <100 ns / <100 nsVoltage protection level Up at In L–N / N–PE / L–PE 1600 V / 1000 V / 1650 V 1200 V / 1000 V / 1500 VMaximum continuous operating voltage Uc L–N / N–PE 335 V AC / 260 V AC 335 V AC / 260 V ACRated frequency 50/60 Hz 50/60 HzNominal discharge current (8/20) µs In L-N/N-PE/L-PE 20 kA 20 kAMaximum discharge current Imax 40 kA 40 kAMaximum back-up fuse 160 A gL 160 A gLMaximum short-circuit current 50 kA 50 kA
Mechanical
Frame size 45 mm 45 mmDevice height 80 mm 80 mmDevice width per pole 35 mm 70 mmWeight per pole 201 g 412 gUpper and lower lift terminal capacity 1–25 mm2 1–25 mm2
DIN rail mountable: on symmetrical DIN railPermitted ambient temperature -40°C to +70°C -40°C to +70°C
Surge ProtectionTechnical Data
Auxiliary Switch for Lightning Current Arrester – Surge Arrester · SPB-HK-W• Field of application: For mounting onto surge protective devices for signal indication.• Design in accordance with IEC 60947-5-1.
Technical Data
Electrical SPC-S-HK
Rated insulation voltage 250 VRated frequency 50/60 HzSwitching contact 1 N/C + 1 N/OMinimum voltage per contact 24 V ACRated operational current AC12 2 A / 250 V ACMaximum back-up fuse 2 A gLOvervoltage category IVPollution degree 2
Mechanical
Frame size 45 mmDevice height 80 mmDevice width 8.8 mmWeight 41 gMounting screw mounting onto
SPB-12/280, SPC-E
Dimensions (mm)
SPC-S-1+1 SPC-S-3+1
35
4580
44
61,5
5,5
70
SPC-S-1+1 SPC-S-3+1
Dimensions (mm)
SPC-S-HK
35
4580
44
61,5
5,5
70
SPC-S-1+1 SPC-S-3+1
128
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
129
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Fuse
Pro
tect
ion
Surge ProtectionTechnical Data
Lead-Through Terminal for Surge Protective Devices · Class B · SPB-D-125• The lead-through terminal permits orderly wiring of SPDs of class B. It serves as lead-through terminal in circuits
requiring vertical connections from the upper to the lower SPD connection level.• Design in accordance with IEC 61643-1: 1998-02 · DIN VDE 0675 Part 6: 1989-11 · IEC 61024-1: 1990-03 ·
IEC 60947-7-1: 1989-10 · DIN VDE 0110-1: 1997-04.
Technical Data
Electrical SPB-D-125
Rated voltage Uc 500 V AC/DCRated current In 125 A / 30°CImpulse current (10/350) µs Peak current 100 kA Charge Q 50 As Specific energy 2.5 MJ/ΩOvervoltage category
Mechanical
Frame size 45 mmDevice height 90 mmDevice width 17.5 mmUpper and lower lift terminal capacity solid 0.5–35 mm2
flexible 0.5–25 mm2
DIN rail mountable: on symmetrical DIN railPermitted relative air humidity < 95%Temperature range -40°C to +85°C
Lead-Through Terminal for Surge Protective Devices · Class C · Z-D63• The lead-through terminal permits orderly wiring of SPDs of class C. It serves as lead-through terminal in circuits
requiring vertical connections from the upper to the lower SPD connection level.
Technical Data
Electrical Z-D63
Rated voltage Uc 500 V AC/DCRated current In 63 ARated frequency 50/60 Hz
Mechanical
Frame size 45 mmDevice height 90 mmDevice width 17.5 mmUpper and lower lift terminal capacity solid 0.5–35 mm2
flexible 0.5–25 mm2
DIN rail mountable: on symmetrical DIN railPermitted relative air humidity < 95%Temperature range -40°C to +85°C
Dimensions (mm)
SPB-D-125
Dimensions (mm)
Z-D63
128
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Surg
e Pr
otec
tion
129
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Fuse
Pro
tect
ion
Fuse ProtectionThe SG range of fuse bases has been introduced as an all-purpose, all-product solution. All bases can be fi tted into consumer units and distribution boards, as well as for independent DIN rail mounting for any application where basic fuse protection is required.
Fuse Protection
Fuse Basesfor use with 10 x 38 gG (gL) fuses
With Visual Trip Indication Max Rated Current (A) Fuse Size Poles Part Number
No 32 10.3 x 38 1 SGI/1
32 10.3 x 38 1+N SGI/1N
32 10.3 x 38 2 SGI/2
32 10.3 x 38 3 SGI/3
32 10.3 x 38 3+N SGI/3N
Single-Pole Fuse Basescomplete with fuse gG (gL)
With Visual Trip Indication Rated Current (A) Fuse Size Poles Part Number
No 10 8.5 x 23 1 SGD/10/1
16 10.3 x 25.8 1 SGD/16/1
20 8.5 x 31.5 1 SGD/20/1
32 10.3 x 38 1 SGD/32/1
Single-Pole and Neutral Fuse Basescomplete with fuse gG (gL)
With Visual Trip Indication Rated Current (A) Fuse Size Poles Part Number
No 10 8.5 x 23 1+N SGD/10/1N
16 10.3 x 25.8 1+N SGD/16/1N
20 8.5 x 31.5 1+N SGD/20/1N
25 10.3 x 31.5 1+N SGD/25/1N
32 10.3 x 38 1+N SGD/32/1N
Yes 10 8.5 x 23 1+N SGDL/10/1N
16 10.3 x 25.8 1+N SGDL/16/1N
20 8.5 x 31.5 1+N SGDL/20/1N
25 10.3 x 31.5 1+N SGDL/25/1N
32 10.3 x 38 1+N SGDL/32/1N
130
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Busb
ar S
yste
ms
131
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Busb
ar S
yste
ms
Busbar SystemsMoeller has an extensive range of busbar solutions. Satisfying the most common requirements, the versatile busbar range includes variants allowing the positioning of power connections at any point along the busbar, to standard cut-to-size metre lengths and pre-defi ned lengths. The perfect solution for any application, ensuring speed and ease of connection.
Busbar SystemsIntroduction
Busbar1 metre length
Current Rating (A) Rated Voltage Rated Impulse Withstand Part Number
50 240 / 415 V 4 kV ZV-SS
80 240 / 415 V 4 kV ZV-SS-80
Note ZV-SS rated at 80 A when Z-D80 is connected for centre feed,ZV-SS-80 rated at 125 A when Z-D80 is connected for centre feed.
Shrouding and Connectorsfor 1 metre length busbar
Description Part Number
Cover section 1 m for 50+80 A ZV-ADP
End caps for busbar cover ZV-AEK
Power feed block 25/50 mm2 Z-D80
Angled Phase Connections · L1, N
Current Rating (A) 10 pieces 36 pieces 100 pieces
50 ZV-L1/N-10 ZV-L1/N-36 ZV-L1/N-100
80 ZV-L1/N-80A-10 ZV-L1/N-80A-36 ZV-L1/N-80A-100
Angled Phase Connections · L2, L3
Current Rating (A) 10 pieces 36 pieces 100 pieces
50 ZV-L2/L3-10 ZV-L2/L3-36 ZV-L2/L3-100
80 ZV-L2/L3-80A-10 ZV-L2/L3-80A-36 ZV-L2/L3-80A-100
130
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Busb
ar S
yste
ms
131
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Busb
ar S
yste
ms
Busbar Fork Connections1 metre length, 25 kA
Description Rated 63 A Rated 80 A
1-phase Z-GV-10/1P-1TE Z-GV-16/1P-1TE
1-phase + auxiliary switch Z-GV-16/1P+HS –
2-phases Z-GV-16/1P+N-2TE –
3-phases Z-GV-10/3P-3TE Z-GV-16/3P-3TE
3-phases Z-GV-10/3P-4TE –
3-phases + auxiliary switch Z-GV-16/3P+HS –
4-phases Z-GV-16/3P+N-4TE –
4-phases Z-GV-16/3P+3N-6TE –
Note Z-GV-10/… rated at 80 A when Z-EK/50 is connected for centre feed,Z-GV-16/… rated at 125 A when Z-EK/50 is connected for centre feed.
Busbar End Caps
Description To Fit 63 A To Fit 80 A
End cap 1-phase Z-V-AK/1P Z-V-AK/1P
End cap 2+3-phases Z-AK-10/2+3P Z-AK-16/2+3P
End cap 4-phase Z-AK-16/4P
Busbar Cable Extension Terminal
Description Part Number
Busbar cable extension terminal 25–50 mm2 Z-EK/50
Accessories
Description Part Number
Busbar tag shrouds ZV-BS-G
Busbar SystemsOpen Ended Busbar Combs
132
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Busb
ar S
yste
ms
Busbar Fork Connections · for 2-Pole Combined RCD/MCB Devicevariable module length · 25 kA
Description Module Width Rated 63A Rated 80 A
1-phase 2+5 EVG-1PHAS/N/2-5MODUL/FILS –
Busbar Fork Connections · for Combination RCD/MCBs with RCD · 4-polevariable module length · 25 kA
Description Module Width Rated 63 A Rated 80 A
3-phases 4+5 EVG-3PHAS/N/5MODUL/LS EVG-16/3PHAS/N/5MODUL/LS
3-phases 4+8 EVG-3PHAS/N/8MODUL/LS EVG-3PHAS/N/8MODUL/LS
Note 80 A EVG can be rated at 125 A when centre-fed.
Busbar SystemsClosed End Commoning Busbar
Busbar Fork Connectionsvariable module length · 25 kA
Description Module Width Rated 63 A Rated 80A
1-phase 2 EVG-1PHAS/2MODUL EVG-16/1PHAS/2MODUL
6 EVG-1PHAS/2MODUL EVG-16/1PHAS/2MODUL
12 EVG-1PHAS/12MODUL EVG-16/1PHAS/12MODUL
2-phases 4 EVG-2PHAS/4MODUL EVG-16/2PHAS/4MODUL
6 EVG-2PHAS/6MODUL EVG-16/2PHAS/6MODUL
12 EVG-2PHAS/12MODUL EVG-16/2PHAS/12MODUL
3-phases 6 EVG-3PHAS/6MODUL EVG-16/3PHAS/6MODUL
9 EVG-3PHAS/9MODUL EVG-16/3PHAS/9MODUL
12 EVG-3PHAS/12MODUL EVG-16/3PHAS/12MODUL
16 EVG-3PHAS/16MODUL EVG-16/3PHAS/16MODUL
20 EVG-3PHAS/20MODUL EVG-16/3PHAS/20MODUL
4-phases 16 EVG-3P+3N/16MODUL –
18 EVG-3P+3N/18MODUL –
8 EVG-4PHAS/8MODUL EVG-16/4PHAS/8MODUL
12 EVG-4PHAS/12MODUL EVG-16/4PHAS/12MODUL
Busbar Fork Connections · with Auxiliary Positionvariable module length · 25 kA
Description Module Width Rated 63 A Rated 80 A
1-phase 2.5 EVG-1PHAS/2MODUL/HI EVG-16/1PHAS/2MODUL/HI
8.5 EVG-1PHAS/6MODUL/HI EVG-16/1PHAS/6MODUL/HI
13 EVG-1PHAS/9MODUL/HI EVG-16/1PHAS/9MODUL/HI
2-phases 4.5 EVG-2PHAS/4MODUL/HI EVG-16/2PHAS/4MODUL/HI
7 EVG-2PHAS/6MODUL/HI EVG-16/2PHAS/6MODUL/HI
12 EVG-2PHAS/10MODUL/HI EVG-16/2PHAS/10MODUL/HI
3-phases 6.5 EVG-3PHAS/6MODUL/HI EVG-16/3PHAS/6MODUL/HI
13.5 EVG-3PHAS/12MODUL/HI EVG-16/3PHAS/12MODUL/HI
3x1-phases 8.5 – EVG-16/3x1PHAS/6MODUL/HI
11.5 – EVG-16/3x1PHAS/8MODUL/HI
13 – EVG-16/3x1PHAS/9MODUL/HI
132
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Busb
ar S
yste
ms
xEnergy Switchboards
Reliably and safely controlling, switching and managing power.In industry, in buildings and in machine construction.Innovative protection concepts.With built-in diagnostics and communication functions.Housed in modern switchboard systems.
NZM circuit-breakers
IZM circuit-breakers
AWe keep power under control.
xEnergy Switchboards
133
134
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
xEne
rgy
Swit
chbo
ards
135
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
xEne
rgy
Swit
chbo
ards
Of course, we all like the idea of progress, but often what we really need are tangible, practical solutions – innovations we can implement and use right now.
And that is precisely why Moeller has developed xEnergy. This new switchboard system has been designed so that you can configure your projects efficiently to meet your own specific requirements – from planning and assembly to installation. It provides the ideal basis for building infrastructures up to 4,000 A.
xEnergy cleverly combines switching and protective devices, mounting systems and enclosure components, so that you can work quickly and efficiently in your workshop and easily integrate future innovations as they arise.
Ideal modules, intelligent system platformMoeller’s new xEnergy system range thinks ahead by allowing for tomorrow’s requirements today. The xEnergy’s switching and
protective devices, mounting and switchboard systems together form a single technical and cost-effective economic unit that offers you the best in power management, switching and control.
How does it work? Quite simply: the new system’s modular design allows for a wide range of intelligent combinations. That means you save time, money and space. And because you can also rely on Moeller’s excellent reputation for safety, you can implement individual projects in functional buildings or office and industrial buildings simply, quickly and flexibly.
xEnergy is available oas flat-pack or partially assembled metalwork to enable the quick assembly of type-tested switchboard to IEC 439, using the Moeller range of circuit protection devices.
xEnergy Switchboards
Make way for progress by integrating innovation
134
134
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
xEne
rgy
Swit
chbo
ards
135
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
xEne
rgy
Swit
chbo
ards
Designed with The Building Regulations part L2 in mindEnergy management is a fundamental part of any power distribution system installed in the UK today, and for the foreseeable future.
Based on our customers’ experi-ences, Moeller design engineers have incorporated the capability to include energy metering at any stage of the design and build process, without having to change anything except the addition of a new door. It can even be incorporated when the distribution board has been installed on site.
xEnergy – reliably and safely controlling, switching and ena-bling the management of power in industry and in buildings.
Functionality is a fundamentalThe xEnergy switchboard system consists of IEC/EN 60439 type-tested function modules. These have an internal separa-tion up to Form 4, and comply with various national or regional installation requirements, such as DIN VDE, CEI, NF or UNE. This means you can design customised solutions for use in several different countries.
The xEnergy system offers you a wide range of options for implementing power distribution reliably, economically and fully in accordance with your customers’ requirements.
You can use feeder and coupling sections for circuit-breakers up to 4,000 A, and individually equipped outgoer sections with fixed compartment modules for switching and protective devices up to 630 A.
Outgoer sections up to 630 A for switch-fuse strips, fuse rails and fuse switch-disconnectors are also available.
Control sections and empty sections can be combined as requi-red for installing ancillary components such as motor starters, PFC modules, frequency inverters, soft starters or for automa-tion solutions. The mounting systems for rail-mounted service installation devices can be used in conventional service distri-bution boards.
IZM and NZM circuit-breakers for xEnergy power sections
Type-tested switchgear assemblies (TTA) up to 4,000 A. Clear and symmetrical design with only one circuit-breaker
per section reduces the number of busbar connections and saves mounting requirements.
Internal separation up to Form 4 increases personnel and system protection.
Fast and direct allocation of circuit-breaker mounting kits for the mechanical fastening of circuit-breakers.
High level of flexibility in the terminal area thanks to alternative connection options.
NZM and PKZ circuit-breakers for xEnergy outgoer sections
3-pole and 4-pole switching and protective devices, type-tested switchboard systems (TTA) up to 630 A.
Max. 38 fixed compartment modules in one section (H 50 mm), optimum device utilisation despite high packing density.
Flexible module mounting to Form 4 with different device mounting depths, however with standard operating front.
Simple module mounting to Form 2 on one mounting depth. Highly flexible combination possible for functional areas
and busbars in accordance with IEC/EN 60439 and national installation practice.
xEnergy Switchboards
136
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
137
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Inde
x
136
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
137
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
Inde
x
automatic re-closing device 87, 90, 116auxiliary contacts 35, 45, 71, 72, 79, 81,
87, 88, 98, 101, 104, 106, 108, 110auxiliary contact blocks 43, 47A & B type distribution boards 11–21bells: See signalling devicesblanking strips 62box terminals 25, 35, 105busbar
for consumer units 10for MCB distribution boards 20for mini panel boards 27for surge protection 121systems 130–132
buzzers: See signalling devicescable lugs 25, 34cable sets 10, 14combined RCD/MCBs: See RCBOscompact distribution boxes
IP30 compact enclosure 56IP40 55IP65 56moisture-proof 54
consumer units 4–10control and switching 8garage units 7insulated 5metal 6outgoing devices 7
control and switching 113–116data management interface module 36diagnostic software 36distribution boards 11–21
A type 12B type 13flat (enclosures) 57–58incoming devices 14
distribution boxesIP40 compact 55IP65 surface-mounted compact 56moisture-proof compact 54
earthing set 62enclosed
MCCBs 45starters 49–52switch disconnectors 46–48switch fuses 42–44
enclosures 53–64flat distribution boards 57–62IP40 compact distribution boxes 55IP65 compact distribution boxes 56moisture-proof distribution boxes 54
energy metering section enclosure 14energy meters 14, 23extension boxes 43, 47extension shafts 105, 107, 109, 111front plates 59
fuse bases 10, 20, 129fuse protection 129garage units 7installation contactors 8, 18, 26, 114installation relays 8, 18, 26, 114isolators 51, 113lead-through terminals 121, 123light intensity switches 9, 18, 26, 114main incoming switches 7, 12, 13main load disconnector switches: See iso-
latorsmarking label 121MCBs (miniature circuit breakers) 65–82
6 kA range [PLS6/PLN6] 66–7210 kA range [PLSM/PLZM] 73–7825 kA range [PLHT] 80–81for consumer units 7for MCB distribution boards 12, 15for MCCB panel boards 33for mini panel boards 24
MCB distribution boards 11–21MCCBs (moulded case circuit breakers)
enclosed 45for MCB distribution boards [LZMB] 14for MCCB panel boards [LZMN/NZM] 32,
36MCCBs and disconnects 103–112MCCB panel boards 31–41
configuration illustration 41metering
connection kits 14, 23current transformers 14, 23kits 14, 23
mini panel board 22–30mounting plate (for marking strip) 62overloads 52panel boards
MCCB 31–41mini panel board 22–30
phase connections, angled 130RCBOs (combined RCD/MCBs) 97–102
double module 99–101for consumer units 7for MCB distribution boards 16single module 98
RCDs (residual current devices) 83–96add-on 89–92conditional surge current proof 88for consumer units 8for MCB distribution boards 12, 13
remote drive operators 107, 109, 111residual current protection 37residual current relay 105, 107, 108, 110rotary drives with handles 105, 109, 111shrouds for outgoing terminations 43, 47shunt releases 35signalling devices 9, 19, 27, 115
staircase switches 9, 18, 26, 114starters, enclosed 49–52surge protection 117–128
accessories 121–122class B+C [SP-B+C] 118class B+C [SPB] 118class B [SPI] 117class C plug-in [SPC-S] 119class C [SPC-E] 119
switching and control: See control and switching
switch disconnectorsfor MCB distribution boards [PN] 14for MCCB panel boards [PN /N] 32
switch disconnectors, enclosed 46–48switch disconnects 104, 106, 108, 110switch fuses, enclosed 42–44switch interlocks 71, 79, 101technical data
A type distribution boards 21B type distribution boards 21enclosed switch disconnectors 48enclosed switch fuses 44enclosures 63–64MCBs [PLHT] 30, 40, 82MCBs [PLN] 82MCBs [PLS, PLZ] 82MCB distribution boards 21MCCBs [LZM] 29, 39, 112MCCBs [N] 112MCCBs [NZM] 39MCCBs [PN] 112MCCB panel boards 38mini panel boards 28RCBOs [PKNM] 102RCBOs [PKS6] 102RCDs [PBHT] 96RCDs [PBSM] 95RCDs [PFDM] 94RCDs [PFIM] 93surge protection 122–128switch disconnectors [N] 40switch disconnectors [PN] 30, 40
terminal blocks 56, 61terminal supports 61time switches
analogue 9, 19, 27, 115digital 9, 19, 27, 115
transformerscore balance 105, 107, 109, 111current 14, 23for signalling devices 10, 19, 27, 116
trip modules 87, 101undervoltage releases 35, 71, 72, 79, 104,
106, 108, 110XBoard consumer units: See consumer unitsxEnergy switchboards 133–135
Index
Index
138
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
139
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
138
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
139
Internal Sales & Technical Support: Tel 01296 397400 · Fax 01296 392413 · Email [email protected] / [email protected] · Web www.moeller.co.uk
AWe keep power under control.
Moeller Electric LimitedPO Box 35, Gatehouse CloseAylesburyBuckinghamshire HP19 8DH
Direct sales ordering and technical supporttel 01296 397400fax 01296 392413email [email protected] [email protected]
© Moeller Electric Limited 05/07
SK0200-271GB