Installing Flexi Cabinet for Indoor (FCIA) DN7064519 Issue 3 en 18/06/2008 # Nokia Siemens Networks 1 (63) 471841A.101 Nokia Flexi EDGE Base Station, Rel. EP2, Product Documentation, v.1
Transcript
Page 1: Dn7064519_Installing Flexi Cabinet for Indoor

Installing Flexi Cabinet for Indoor(FCIA)

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 1 (63)

471841A.101Nokia Flexi EDGE Base Station, Rel. EP2,Product Documentation, v.1

Page 2: Dn7064519_Installing Flexi Cabinet for Indoor

The information in this document is subject to change without notice and describes only theproduct defined in the introduction of this documentation. This documentation is intended for theuse of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted inany form or means without the prior written permission of Nokia Siemens Networks. Thedocumentation has been prepared to be used by professional and properly trained personnel,and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomescustomer comments as part of the process of continuous development and improvement of thedocumentation.

The information or statements given in this documentation concerning the suitability, capacity, orperformance of the mentioned hardware or software products are given “as is” and all liabilityarising in connection with such hardware or software products shall be defined conclusively andfinally in a separate agreement between Nokia Siemens Networks and the customer. However,Nokia Siemens Networks has made all reasonable efforts to ensure that the instructionscontained in the document are adequate and free of material errors and omissions. NokiaSiemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues whichmay not be covered by the document.

Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NOEVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THISDOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL,DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUTNOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESSOPPORTUNITY OR DATA, THAT MAYARISE FROM THE USE OF THIS DOCUMENT OR THEINFORMATION IN IT.

This documentation and the product it describes are considered protected by copyrights andother intellectual property rights according to the applicable laws.

The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark ofNokia Corporation. Siemens is a registered trademark of Siemens AG.

Other product names mentioned in this document may be trademarks of their respective owners,and they are mentioned for identification purposes only.

Copyright © Nokia Siemens Networks 2008. All rights reserved.

2 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 3: Dn7064519_Installing Flexi Cabinet for Indoor

Contents

Contents 3

1 Summary of changes 5

2 Overview of installing FCIA 7

3 Unpacking and checking FCIA delivery 9

4 Changing the opening direction of the FCIA door 11

5 Lifting the FCIA 17

6 Installing the cabinet 216.1 FCIA clearances and anchoring holes 216.2 Anchoring the FCIA 24

7 Grounding the FCIA 29

8 Installing optional items 338.1 Installing optional lifting handles in FCIA 338.2 Installing batteries 348.2.1 Overview of battery backup solution for FCIA 348.2.2 Installing batteries in FCIA 358.2.3 Installing MIBBU WPUB (469784A) and WPUC (469955A) 388.2.4 Installing rectifier units (WPMB/WPMC) 488.2.5 Connecting battery backup alarms in FCIA 508.2.6 Changing the alarm polarity and disabling the LTE distribution alarm of the

WPUB unit 528.2.7 Changing the alarm polarity and disabling the LTE distribution alarm of the

WPUC unit 55

9 Checklist for installing FCIA 59

Appendix A Installation tools and torque values 61A.1 Installation tools for Flexi EDGE BTS 61A.2 Torque values 62

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 3 (63)

Contents

Page 4: Dn7064519_Installing Flexi Cabinet for Indoor

4 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 5: Dn7064519_Installing Flexi Cabinet for Indoor

1 Summary of changesChanges between issues 3-0 and 2-0

Updated chapters:

. Installing the rectifier units (WPMB/WPMC) updated with a referenceto FMRx documentation.

. Connecting battery backup alarms for FCIA updated with a newfigure of connecting battery backup alarms in FCIA.

. Changing the alarm polarity and disabling the LTE distribution alarmof the WPUB unit instructions for changing the alarm polarityupdated and information on disabling LTE distribution alarm added

. Changing the alarm polarity and disabling the LTE distribution alarmof the WPUC unit information on disabling LTE distribution alarmadded

Removed chapters:

. Appendix A: Contents of delivery

Changes between issues 2-0 and 1-0

New chapters:

. Summary of changes

. FCIA clearances and anchoring holes

. Overview of battery backup solution for FCIA

. Connecting battery backup alarms for FCIA

Updated chapters:

. Installing PDU for battery backup figure updates made.

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 5 (63)

Summary of changes

Page 6: Dn7064519_Installing Flexi Cabinet for Indoor

Removed chapters:

. Installing Flexi System External Alarm (FSEB)

. FSEB interface signals and connector pin assignments

6 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 7: Dn7064519_Installing Flexi Cabinet for Indoor

2 Overview of installing FCIAPurpose

This is an overview of how to install Nokia Flexi Cabinet for Indoor (FCIA).

Before you start

Check that you have the needed installation tools available. See AppendixInstallation tools and torque values.

Warning

This equipment generates electromagnetic fields. If performinginstallation or maintenance procedures on a base transceiverstation (BTS), make sure that all the transmitters in the area areswitched off.

Warning

The antenna generates electromagnetic fields at radiofrequencies. Do not cross the compliance boundary.

Steps

1. Check that the site meets the installation requirements.

For more information, see Requirements for Installation andOperation document.

2. Unpack and check the delivery.

3. Install the lifting handles, if needed.

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 7 (63)

Overview of installing FCIA

Page 8: Dn7064519_Installing Flexi Cabinet for Indoor

4. Lift the cabinet to the installation location, if needed.

5. Change the door opening direction, if needed.

6. Anchor the cabinet on to the base.

7. Prepare the cabinet cable entries.

8. Route the grounding cable and ground the cabinet.

9. Install the Integrated Battery Backup, if needed.

See. Installing batteries in FCIA. Installing the rectifier units (WPMB/WPMC). Installing Power Distribution Unit in FCIA. Changing the alarm polarity of the WPUB unit. Changing the alarm polarity of the WPUC unit. If you using the Flexi Rectifier Module (FRMA, FRMB or

FRMC), see the installation instructions in NOLS.

Further information

Next, install the modules inside the cabinet, and route and install thecables. For instructions, see the Creating FCIA Configurations document.documents.

8 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 9: Dn7064519_Installing Flexi Cabinet for Indoor

3 Unpacking and checking FCIA deliveryBefore you start

Warning

Base Transceiver Station (BTS) cabinets have sharp edges. Takecare when working with or near the BTS.

The cabinet must be in a horizontal position when unpacking the delivery.

Summary

Figure 1. Flexi Cabinet for Indoor (FCIA) package dimensions

1820 mm(71.6 in)

580 mm(22.8 in)

626 mm(24.6 in)

DN07084962

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 9 (63)

Unpacking and checking FCIA delivery

Page 10: Dn7064519_Installing Flexi Cabinet for Indoor

Steps

1. Check the cardboard delivery packing for any damage beforeproceeding with the unpacking.

2. Remove the packing ribbons.

3. Lift the cardboard cover from around the cabinet.

4. Lift the cardboard lid away from the package.

5. Remove the installation template.

The installation template is needed when the cabinet is anchored tothe base.

6. Remove the cardboard sleeve from around the cabinet.

7. Remove the plastic cover from around the cabinet.

8. Remove the desiccant packs.

9. Check the cabinet for any damage.

10. Lift the cabinet to an upright position.

11. Check that the delivery is correct and complete by comparingthe contents of the delivery to the packing list.

See Contents of delivery for more information.

12. Place the packing list into the site folder.

Further information

It is the responsibility of the customer to maintain and archive site-specific documents. The site folder should contain all the requiredsite-specific information. It should include installation,commissioning, and integration check lists. Note, however, that theexact contents of a site folder is defined by the customer project.

13. Recycle the packing material in accordance with your nationalrecycling recommendations.

10 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 11: Dn7064519_Installing Flexi Cabinet for Indoor

4 Changing the opening direction of theFCIA door

Purpose

Follow these instructions if you need to change the door opening directionof Nokia Flexi Cabinet for Indoor (FCIA).

If necessary, remove and install the door lock-plate on the opposite side ofthe cabinet.

Steps

1. Remove the ground wire and hinge pins, and detach the door.

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 11 (63)

Changing the opening direction of the FCIA door

Page 12: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 2. Remove the hinge pins and detach the door (1).

2. Loosen the hinge screws and remove the hinges.

See the figure below.

3. Install the hinges on the opposite side of the cabinet.

Tip: Remove the lower hinge first

1

DN7086696

12 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 13: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 3. Loosen the hinge screws and remove the hinges (2). Install thehinges on the opposite side of the cabinet (3).

4. Remove the door lock-plate.

See the figure below.

5. Install the door lock-plate on the opposite side of the cabinet.

TightenInstall the hingeon the oppositeside of the cabinet

Removethe hinge

2

Loosenthe hingescrew

3

DN7086715

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 13 (63)

Changing the opening direction of the FCIA door

Page 14: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 4. Remove the door lock-plate (4). Install the door lock-plate on theopposite side of the cabinet (5).

6. Flip the door end-to-end.

4

Loosenscrews

5

DN7086739

14 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 15: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 5. Flip the door end-to-end (6).

7. Mount the door on the opposite side, reinstall the ground wireand attach the hinge pins.

180o

DN7086766

6

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 15 (63)

Changing the opening direction of the FCIA door

Page 16: Dn7064519_Installing Flexi Cabinet for Indoor

16 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 17: Dn7064519_Installing Flexi Cabinet for Indoor

5 Lifting the FCIAPurpose

Follow these instructions when you need to lift Flexi Cabinet for Indoor(FCIA) to the desired installation location.

You can also install optional lifting handles (WLHA) to lift the cabinet. Forinstructions, see Installing optional lifting handles in FCIA.

Before you start

Warning

The cabinets are heavy. Additional personnel or lifting equipmentmay be needed when the cabinets are moved, unpacked, or linedup. In addition, follow any local regulations applicable to theinstallation.

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 17 (63)

Lifting the FCIA

Page 18: Dn7064519_Installing Flexi Cabinet for Indoor

Summary

Figure 6. Lifting the FCIA

Note that empty FCIA cabinet weighs 62 kilograms (136 lbs.).

Steps

1. Attach the 4 x M12 lifting eye bolts to the attachment points.

Lifting eye bolts are not included in the delivery. See figure Lifting theFCIA above, step 1.

2. Attach the hoisting belt or the rope to the lifting eye bolts.

Make sure that the hoisting belt or rope loop is high enough to avoidbending the equipment. See figure Lifting the FCIA above, step 1.

3. Lift the cabinet carefully to the desired installation height.

DN7084974

Minimum500 (19.6)

NOTE: Dimensions: mm (in.)

2

1

18 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 19: Dn7064519_Installing Flexi Cabinet for Indoor

See figure Lifting the FCIA above, step 2.

4. Mount the cabinet.

5. Remove the lifting equipment.

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 19 (63)

Lifting the FCIA

Page 20: Dn7064519_Installing Flexi Cabinet for Indoor

20 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 21: Dn7064519_Installing Flexi Cabinet for Indoor

6 Installing the cabinet

6.1 FCIA clearances and anchoring holes

See the following table and figures for required clearances around NokiaFlexi Cabinet for Indoor (FCIA).

Table 1. Cabinet clearances

Property Required clearance

Front of the cabinet 900 mm (35.4 in.)

Behind the cabinet 50 mm (2.0 in.)

Behind the cabinet (with maintenancespace in the back) 1)

500 mm (19.7 in.) with side access

Space on the door hinges side of thecabinet

50 mm (2.0 in.)

Door swing radius 600 mm (23.6 in.)

Above the cabinet 300 mm (11.8 in.)

1) For maintenance space in the back, side access of 500 mm (19.7 in.) isalso needed.

The floor must be level. The level tolerance is ± 5 mm (0.19 in.) for thebase area immediately under the cabinet.

A 50 mm (2.0 in.) backstop is included in the cabinet delivery. Theclearance behind the cabinet is measured from the back wall of thecabinet.

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 21 (63)

Installing the cabinet

Page 22: Dn7064519_Installing Flexi Cabinet for Indoor

When installing 3rd party 19" rack equipment in the FCIA, the distancefrom the rack fixing space to the inner surface of the door must be 102.5mm (4.0 in.).

For the dimensions of the FCIA cabinet, see dimensions and weight.

Figure 7. Clearances around FCIA

DN7083227

300 mm(11.8 in)

900 mm(35.4 in)

Front

Maintenancespace500 mm(19.7 in)

Top view

600 mm(23.6 in)

570 mm(22.4 in)

Doorswing radius

600 mm (23.6 in)

50 mm(2.0 in)

Height1800 mm(70.87 in)

Width600 mm(23.62 in)

Depth600 mm

(23.62 in)

22 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 23: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 8. FCIA fixing points, minimum clearances

Facility wall

Back stop

Front

600 mm(23.6 in)

457 mm(18.0 in)

71.5 mm(2.8 in)

71.5 mm(2.8 in)

300 mm(11.8 in)

570 mm(22.4 in)

620 mm(24.4 in)

179 mm(7.0 in)

DN7083242

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 23 (63)

Installing the cabinet

Page 24: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 9. FCIA fixing points with maintenance space in the back

Anchoring holes

The cabinet is anchored to the ground using four M10 or M12 bolts. Theoptional mounting holes are available for backup purposes, in case theofficial holes cannot be used for some reason.

6.2 Anchoring the FCIA

Purpose

Flexi Cabinet for Indoor (FCIA) must be anchored to the base if there isany risk of it toppling for example in areas with an earthquake risk.

Facility wall

Back stop

Front

600 mm(23.6 in)

457 mm(18.0 in)

71.5 mm(2.8 in)

71.5 mm(2.8 in)

300 mm(11.8 in)

570 mm(22.4 in)

1070 mm(42.1 in)

629 mm(24.8 in)

DN7086669

24 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 25: Dn7064519_Installing Flexi Cabinet for Indoor

The cabinet should be attached to the base with M10 or M12 anchor bolts,nuts, and washers (4 pcs each). The recommended anchor bolt length is60 mm (2.36 inches). Anchor bolts and nuts are not provided with thedelivery and must be acquired locally.

Before you start

Check that the base is planned and prepared.

Steps

1. Pull out the back stop.

2. Attach the cabinet to the base.

An anchor bolt should be protruding up through each bolting hole.Secure the nuts and washers to the bolts and tighten to therecommended torque.

Attach the cabinet with four bolts, nuts and washers. Adjust theheight of the nuts so that the cabinet is level.

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 25 (63)

Installing the cabinet

Page 26: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 10. FCIA anchor holes

Tip

When considering if the cabinet is level or not, a useful test is to checkthat the door of the cabinet closes properly. If the door does not closeproperly, the cabinet is not level. Another way is to use cross-measureto verify that the cabinet is level.

DN7085007

Cabinet feet adjustment(use a flathead screwdriver)

Anchor hole

26 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 27: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 11. Bolting the indoor cabinet

Use the template in the package for drilling the screw holes and fordefining the required clearances.

3. Adjust the cabinet feet firmly against the floor.

4. Check that the cabinet is still level.

DN02164471

Floor

Cabinet fixing nut

Cabinet spring washer

Anchor bolt

Adjustable feet (4pcs)

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 27 (63)

Installing the cabinet

Page 28: Dn7064519_Installing Flexi Cabinet for Indoor

Check that the cabinet is still level. If necessary, adjust the anchorbolts and cabinet feet (uneven bolting may damage the cabinet).

28 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 29: Dn7064519_Installing Flexi Cabinet for Indoor

7 Grounding the FCIASummary

Figure 12. Grounding (earthing) points of Nokia Flexi Cabinet for Indoor (FCIA),top view

M5M8

DN7087017

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 29 (63)

Grounding the FCIA

Page 30: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 13. Grounding the FCIA, side view

For NEBS installations, use a two-hole compression lug to connect theground cable to the cabinet with two M5 star washers and screws.

Steps

1. Make sure the grounding cable is fixed to the grounding point.

2. At the top of the cabinet, remove the screw and star washer.

3. Strip approximately 2 cm (0.75 in.) off the main ground cable.

4. If this is a NEBS installation, bring the mating surfaces of allunplated ground connections to a bright finish, using emerycloth (or other suitable method). Then coat the exposed groundcable conductor with antioxidant.

5. Insert the stripped end of the cable into a cable shoe lug andcrimp.

6. Fit the lug end of the grounding cable over the groundconnection and fix with the star washer(s) and screw(s).

Tighten to 3.5-4.2 Nm (2.58-3.10 ft-lb).

Cabinetground cable

Cabinetground cable

Side view of cabinet

Star washer

B

Bolt

Lug

A

DN7086921

30 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 31: Dn7064519_Installing Flexi Cabinet for Indoor

Further information

The modules are grounded to cabinet rack, and no separate groundingcables are required.

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 31 (63)

Grounding the FCIA

Page 32: Dn7064519_Installing Flexi Cabinet for Indoor

32 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 33: Dn7064519_Installing Flexi Cabinet for Indoor

8 Installing optional items

8.1 Installing optional lifting handles in FCIA

Purpose

The Lifting Handle Kit (WLHA) can be installed on the sides of the cabinet.

Steps

1. Align the handle screw holes with the four M5 screw holes onthe side of the cabinet.

2. Fix the handle to the cabinet with four M5 screws provided withthe kit.

See the figure Attaching the lifting handles below.

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 33 (63)

Installing optional items

Page 34: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 14. Attaching the lifting handles

3. Repeat for the other handle.

8.2 Installing batteries

8.2.1 Overview of battery backup solution for FCIA

The FCIA long-term battery backup solution consists of a PowerDistribution Unit (PDU or MIBBU) and batteries installed the FCIA cabinet.The PDU converts AC power into DC power, which is then used by theBTS. In the default configuration, alarms are routed from the PDU to theSystem Module.

4xM5

4xM5

DN70293793

34 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 35: Dn7064519_Installing Flexi Cabinet for Indoor

The following HW is required for installing batteries in FCIA:

. Batteries. Power safe battery 4 x 12V62F. Power safe battery 4 x 12V92F

. Rectifier Units (WPMB/WPMC)

. Power Distribution Unit (PDU) (WPUB/WPUC)

. Flexi EDGE Battery Alarm cable (EBCA)

. Battery DC cable set (not included in Flexi EDGE BTS delivery). Forrequirements, see Installing batteries in FCIA

. BTS DC cable set (not included in Flexi EDGE BTS delivery). Forrequirements, see Installing Power Distribution Unit in FCIA

8.2.2 Installing batteries in FCIA

Before you start

When using batteries with Flexi Cabinet for Indoor (FCIA), Flexi MountingKit for Batteries (FMBB) is needed. The mounting kit is installed at thebottom of the cabinet. You can use one of the following battery options:

. Power safe battery 4 x 12V62F

. Power safe battery 4 x 12V92F

Battery cable requirements are:

. 2 sets of 1000 mm (39.3 in.) DC cable

. 1/0 AWG (35 mm2) wire thickness

. 2 x Anderson connectors rated at 180 Amps (one for each DC cableset)

. 4 x M10 ring cable lugs (two for each DC cable set)

. 2 x rubber boots for cable lugs

Check the torque value, it should be 3.5-4.2 Nm (2.58-3.10 ft-lb). Seesection Torque values in the appendix for correct torque values.

Battery cables are not included in the delivery. The cables must be madein the field.

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 35 (63)

Installing optional items

Page 36: Dn7064519_Installing Flexi Cabinet for Indoor

Note that Nokia cable 994954a is 1000 mm in length and meets theserequirements. The cable can be ordered as a spare part. Two pcs areneeded for FCIA installations.

Summary

36 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 37: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 15. Installing batteries in FCIA

4 6

4x12V92F

DN7089218

back plate stiffener

1 32

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 37 (63)

Installing optional items

Page 38: Dn7064519_Installing Flexi Cabinet for Indoor

Steps

1. Install the battery bottom plate.

2. If you are using 12V92F batteries, remove the plate stiffenerfrom the battery back plate.

Store the plate stiffener and the battery fixing adjuster for later usewith 12V62F batteries if needed.

3. Install the battery back plate.

4. Install the batteries.

5. If you are using 12V62F batteries, remove the front platestiffener from the battery front plate and install the battery fixingadjuster. Store the front plate stiffener for later use with 12V92Fbatteries if needed.

6. Install the battery front plate and tighten with six screws.

7. Connect the cable lug end of one set of the 1000 mm cables tothe batteries. Tighten to 5 Nm (3.7 ft-lb). Make sure you installthe rubber boots. The other 1000 mm cable set will beconnected later to the PDU.

Connect the minus (-) power cable first, and then the plus (+) one.

Route the cables from the back.

8. Install the battery bridges.

Warning

Danger of hazardous voltages and electric shock! When installingthe battery bridges, make sure the tool does not touch metal.

8.2.3 Installing MIBBU WPUB (469784A) and WPUC (469955A)

Purpose

The Power Distribution Unit (PDU) is utilised in Flexi Cabinet for Indoor(FCIA) when battery backup is used. Either WPUB or WPUC can be used.

38 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 39: Dn7064519_Installing Flexi Cabinet for Indoor

The PDU converts the AC power into DC power, which the base stationuses.

Install the PDU in the top 3U of the cabinet so that the AC terminal can bemounted on the roof.

Before you start

Prepare DC cables for both the batteries and System modules.

. Other half of battery cables from Installing batteries in FCIA

. One set of DC cables from PDU to the System module. 4 AWG (25 mm2). 1500 mm (78.7 in.). 2 extra cable lugs with M10 rings are required

. Open the PDU and take out the installation parts.

. Connect the power cables to the PDU before installing it in the rack.

. Check that the alarm polarity is correct. The default setting for thealarm polarity is Normally Open. If you need to change it, seeChanging the alarm polarity for the WPUB unit or Changing thealarm polarity for the WPUC unit, depending on your base stationsetup. Remember also to change the Intelligent Shutdown polarity, ifusing it.

Caution

Risk of short circuit. Make sure that all the breakers on the powerdistribution unit (PDU) front panel are in the OFF position before youconnect the cables.

Steps

1. Remove the plastic cover from the back of the PDU.

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 39 (63)

Installing optional items

Page 40: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 16. Principle of connecting the control card power feeding cable to PDU

2. Attach the DC cables to the rear of the PDU.

DN0550465

40 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 41: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 17. Connecting DC cables to PDU

Figure 18. Connecting DC cables to PDU (WPUB)

+ + ---

BTS - Battery -Common+

DN7089206

Top view WPUB cabling

+ + -

Connectthe cables

Remove theplastic cover

--

DN7068106

Controlcard

-

BTS

-

Battery

+

BTS

+

Battery

-

Controlcard

+

BTS - Battery - Common+

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 41 (63)

Installing optional items

Page 42: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 19. Connecting DC cables to PDU (WPUC)

3. Reinstall the plastic cover on the PDU.

4. If you are using the WPUB unit, connect the thermal sensorcable to the back of the PDU.

5. Install the guide plates and cage nuts for the PDU.

Fix with four M5 screws.

1

Removetheplasticcover

Top view WPUC cabling

45 degreesor less

DN70120077

BTS - Battery - Common +

Controlcard

-

Battery

-

Controlcard

+

Battery

+

Remove theplastic cover

BTS

-

BTS

+

Connectthe cables

42 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 43: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 20. Mounting the PDU

6. Slide the PDU halfway into the cabinet. Keep both set of DCcables routed down the back of the unit.

7. Route the AC terminal plate up through the back hole on theFCIA roof.

DN70274146

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 43 (63)

Installing optional items

Page 44: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 21. Installing AC terminal plate

8. Slide the PDU all the way into the cabinet and mount it.

9. Mount the AC terminal terminal plate on the roof.

10. Connect the AC cable to the AC terminal plate.

See the following figures for AC cable connections.

DN70286282

44 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 45: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 22. Single phase, 230 V AC

DN02165007

Cable routingsupport

AC Powerinput cable

Bridges

N1

N2

N3

L1

L2

L3

PE

L1/L2/L3= PhaseN= Neutral, PE= Protective earth

1~ Connection

N

PE

N1N2N3PE

LL1L2L3

Single Phase connection

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 45 (63)

Installing optional items

Page 46: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 23. 3-phase (delta), base voltage 100-120 V AC

DN02178657

Cable routingsupport

AC Powerinput cable

L1/L2/L3= PhaseN= Neutral, PE= Protective earth

PE

N1N2N3PE

L1L1L2L3

L2L3

3~ Connection

L1

L2

L3

N1

N2

N3

PE

3-phase delta connection

46 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 47: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 24. 3-phase (star), 230 V AC

11. Install the AC terminal plastic cover.

12. If you are using the WPUC unit, connect the battery thermalsensor cable to the front panel of the PDU.

13. Fix the battery cables to the battery front plate with cable ties sothat they cross each other.

14. Route the thermal sensor cable and push the rubber plug inplace.

15. Connect the EBCA alarm cable from the EAC connector on thePDU to the FPA connector on the System module.

DN02178645

Cable routingsupport

AC Powerinput cable

L1/L2/L3= PhaseN= Neutral, PE= Protective earth

3~Y Connection

N

PE

N1N2N3PE

L1L2L3

L1L2L3

L1

L2

L3

N1

N2

N3

BridgePE

3-phase star connection

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 47 (63)

Installing optional items

Page 48: Dn7064519_Installing Flexi Cabinet for Indoor

Fix with cable ties.

16. Connect the battery cable connector from the PDU to thebattery cable connector from the batteries.

8.2.4 Installing rectifier units (WPMB/WPMC)

Purpose

The PDU provides four slots for rectifiers. Each of the PDU versions(WPUB/WPUC) has its own rectifier unit: WPMB/WPMC. Install therectifier units as described in these instructions.

Before you start

Remove the dummy panels from the PDU.

Steps

1. Install the rectifier units.

Install the rectifier units in their places. Note that if the rectifier is thetype that has the retaining hooks (WPMB), the hooks must be in anopen position before fixing the unit in place. Use a small screwdriverin the holes in the upper left- and right-hand corners of the unit torelease the hooks.

48 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 49: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 25. Installing the rectifiers, WPMB (top) and WPMC (bottom)

2. Secure the units.

When the unit is in place, tighten the knurled-head fixing screw orinsert the retaining hooks in their slots, depending on the unit typeused.

Retaining hooks

Fixing screw

1

2

DN0424983

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 49 (63)

Installing optional items

Page 50: Dn7064519_Installing Flexi Cabinet for Indoor

Caution

The retaining hooks are fragile. Do not carry the unit by the retaininghooks.

3. Switch on the breakers on the PDU front panel.

Turn the breakers on the PDU front panel into the ON position.

Warning

Risk of electric shock. Do not switch on the breakers before thebase transceiver station (BTS) installation is complete.

4. Close the lid.

Further information

If you are using the Flexi Rectifier Module (FRMx), see Principles forinstalling FRMA, FRMB and FRMC in Flexi EDGE BTS configurations indocument Installing Nokia Flexi EDGE BTS Optional Items.

8.2.5 Connecting battery backup alarms in FCIA

The alarm system for the batteries is “plug and play”. No configuration orconnection to an external alarm box is required if the default alarms areused and the EBCA cable is used. The EBCA cable connects from theEAC connector on the PDU to the FPA connector on the System module.See the following figure for an illustration on connecting battery backupalarms in FCIA.

50 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 51: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 26. Connecting battery backup alarms in FCIA

Note that the FSEB is not required for battery backup alarms in FlexiEDGE FCIA configurations because the default alarms are routed to theSystem module with the EBCA cable.

The default alarms are:

. Mains 1 - Mains breakdown with battery backup

. Mains 2 - Mains breakdown with battery backup

. Mains 3 - Mains breakdown with battery backup

. PSM 1 - Site powering faulty

. PSM 2 – Site powering operation degraded

. PSM 3 – Site powering notification

See the following table for the EBCA cable alarm pin configuration.

DN70521063

ESM

EACX-S

ESMAWPUB/C

FSEB

WLB alarm

EAC

471464A

FPA

994945

EAC

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 51 (63)

Installing optional items

Page 52: Dn7064519_Installing Flexi Cabinet for Indoor

Table 2. EBCA cable alarm pin configuration

D-9 Connector RJ45 Connector

Pin Signal Pin Signal

1 Mains 1 1 Mains 1

2 Mains 2 2 Mains 2

3 Mains 3 3 Mains 3

4 PSM 1 4 PSM 1

5 PSM 2 5 PSM 2

6 PSM 3 6 PSM 3

7 NC 7 GND

8 NC 8 GND

9 GND 9 NC

If it is required to change the default PDU alarm configuration, a customcable is needed to connect from the PDU alarms to the FSEB or otherexternal alarm box. For more details about the PDU alarms, see theWPMB/WPMC description in the Nokia UltraSite WCDMA Base StationOptima Compact Outdoor (WREB) product documentation.

Steps

1. Connect the EBCA cable from EAC connector on the PDU to theFPA connector on the System Module.

2. Tie the cable to the side of the cabinet.

8.2.6 Changing the alarm polarity and disabling the LTE distribution alarmof the WPUB unit

Purpose

The EAC alarm polarity can be set to two states, Normally Open orNormally Closed.

The Normally Open state means that the galvanic EAC alarm circuit loop isopen and electric current is not flowing through it. The corresponding EACalarm is activated if the EAC alarm circuit loop is closed.

The Normally Closed state means that the galvanic EAC alarm circuit loopis closed and electric current is flowing through it. The corresponding EACalarm is activated if the EAC alarm circuit loop is opened.

52 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 53: Dn7064519_Installing Flexi Cabinet for Indoor

The default alarm polarity is Normally Open. Make sure that you set theEAC alarm polarity correspondingly during BTS commissioning.

Before you start

If changing the polarity is needed, it is recommended to do this beforeinstalling the WPUB unit into the cabinet.

Caution

Always use an ESD wrist strap when handling units labelled with theESD sign. Labelled units are sensitive to electrostatic discharge.

Steps

1. Lift off the plastic cover on the backside of the WPUB unit.

2. Remove the screws that attach the cover to the unit and lift offthe cover.

Remove the four screws on the top and three uppermost screws oneach side of the unit.

Note that disabling the LTE distribution alarm does not requireremoving the cover.

3. Move the position of the jumpers so that the required alarmbehaviour is met.

The text on the interface board shows how the jumpers should bemounted for Normally Open (NO) and Normally Closed (NC) states.

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 53 (63)

Installing optional items

Page 54: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 27. Changing the alarm polarity of the WPUB unit

4. Disable the LTE distribution alarm if needed.

To disable the alarm, connect the wire between the pins 10 and 11 ofthe CON41 connector.

JP7

JP8

CON5

NC

NO

NC

NO

7

REL7

REL8

NO

NC

JP1 JP6JP5JP4JP2JP3

1 2 3 4 5 68

RELAY

+

-

CON5

NC

NO

NC

NO

7

REL7

REL8

NO

NC

JP1 JP6JP5JP4JP2 JP3

1 2 3 4 5 68

RELAY

JP7

JP8

+

-

Disabling LTE alarm

54 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 55: Dn7064519_Installing Flexi Cabinet for Indoor

8.2.7 Changing the alarm polarity and disabling the LTE distribution alarmof the WPUC unit

Before you start

There are eight galvanic isolated alarm contacts for remote supervision ofthe alarms. Each alarm contact represents different alarm conditions.Alarm relay coils are powered during normal operation. All alarm relays willgive an alarm with no AC or DC power connected to the system.

Figure 28. Alarm connection, 9-pin D-sub

Tip

If changing the polarity and/or disabling the LTE distribution alarm isneeded, it is recommended to do this before installing the WPUC unitinto the cabinet.

Alarm 1: Pin 1Alarm 2: Pin 2Alarm 3: Pin 3Alarm 4: Pin 4Alarm 5: Pin 5Alarm 6: Pin 6Alarm 7: Pin 7Alarm 8: Pin 8Common: Pin 9

Alarms EAC

1 2 3 4 5

6 7 8 9

DN0570839

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 55 (63)

Installing optional items

Page 56: Dn7064519_Installing Flexi Cabinet for Indoor

Caution

Always use an ESD wrist strap when handling units labelled with theESD sign. Labelled units are sensitive to electrostatic discharge.

Steps

1. Loosen the fixing screw and pull out the alarm interface unitusing the handle.

2. Use JP8 for setting the alarm relays to closed on alarm or openon alarm.

The jumper mounted between pins 1 and 2 on the jumpers (default)means closed on alarm for the corresponding relay.

The jumper mounted between pins 2 and 3 on the jumpers meansopen on alarm for the corresponding relay.

The jumper numbers correspond to the relay numbering (forinstance, JP5 to RL5).

Note that when the jumpers are mounted between pins 1 and 2, thealarm polarity is Normally Open. When the jumpers are mountedbetween pins 2 and 3, the alarm polarity is Normally Closed.

56 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 57: Dn7064519_Installing Flexi Cabinet for Indoor

Figure 29. Alarm interface unit from above

3. Disable the LTE distribution alarm if needed.

LTE distribution alarm is controlled with the jumper JP4.

As default, the alarm is active and the jumper is mounted betweenpins 1 and 2. Mount the jumper between pins 2 and 3 to disable thealarm.

4. Reinstall the alarm interface unit.

Q5

R64 R62 R60 R90 R82 R84 R85R63 R61

JP5

Jumper settings

Alarm

sEAC

RL6

RL8

C21

R30

R21D3

R37 P2

P3

JP3

JP41

R26D1

D4

1 1

JP12

11

JP11

JP10

JP9

1 1

JP8

JP7

1 1

JP6

RL5

RL7

RL10 RL9

RL12 RL11

J12

SC6

R29

JP2

C24

Q6

DN0570842

J1

LTE alarm

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 57 (63)

Installing optional items

Page 58: Dn7064519_Installing Flexi Cabinet for Indoor

58 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 59: Dn7064519_Installing Flexi Cabinet for Indoor

9 Checklist for installing FCIA

Table 3. Checklist for installing Flexi Cabinet for Indoor (FCIA)

Work phase Checked

Delivery is complete and undamaged.

Cabinet is anchored.

Cabinet is grounded.

Flexi System External Alarm (FSEB) is installed (if needed).

Battery backup is installed (if needed).

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 59 (63)

Checklist for installing FCIA

Page 60: Dn7064519_Installing Flexi Cabinet for Indoor

60 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 61: Dn7064519_Installing Flexi Cabinet for Indoor

Appendix A Installation tools and torque values

A.1 Installation tools for Flexi EDGE BTS

This list covers all Flexi EDGE BTS installation options: stack, wall, pole,Flexi Cabinet for Indoor (FCIA), Flexi Cabinet for Outdoor (FCOA), Citytalkcabinet, feederless sites.

Table 4. Installation tools

Installation tools Usage

ESD wrist strap and cable Module/sub-module installation

TORX screwdriver set: T10, T20, T25, T45 . Installing modules (T25). Installing casing kits (T25). Module grounding (T25). FCIA/FCOA/FCFA/FCSA/FMFA mechanics

(T25). Installing sub-modules (T20). Fan plate assembly (T20). Anchoring EMIA standoff casing (T45). FCIA site grounding (T45). Isolating cable clamps (T10). EMIA door alarm kit (T10)

Socket or open-ended spanner (wrench) set:

8 mm (5/16 in.), 13 mm (1/2 in.), 17 mm (11/16) in.), 19 mm(13/16 in.)

Torque wrench is recommended for fastening the DC input lug.

. DC power terminal nuts (17 mm)

. Plinth site grounding (13 mm)

. FCOA site grounding (13 mm, 8 mm)

. Anchoring cabinets/plinths (19 mm)

Folding knife . Unpacking. Routing cables through cable entries. Preparing power and ground cables

Adjustable wrench General installation tool

Side cutters Cutting tie wraps, general installation tool

Crimping tool for 16 mm2 (6 AWG), 25 mm2 (4 AWG), 35 mm2

(2 AWG), or 50 mm2 (1/0 AWG) cable lugsGrounding and DC power input cables

Torque wrench for antenna cables (size depends on antennajumper/feeder cable size and manufacturer)

Connecting antenna cables to ERxA or ECxA

Cable ties Routing cables

Tape measure General installation tool

Flashlight, pocket lamp or torch General installation tool

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 61 (63)

Installation tools and torque values

Page 62: Dn7064519_Installing Flexi Cabinet for Indoor

Table 4. Installation tools (cont.)

Installation tools Usage

Drill with bit set: 10 mm (3/8 in.), 12 mm (15/32 in.) . Anchoring cabinets/plinths (12 mm). EMIA installation (10 mm)

Marker, pen, or comparable tool General installation tool

Pliers General installation tool

Level General installation tool

Flathead screwdriver FPMA AC power terminals

Allen (Hexagon) keys: 4 mm (5/32 in.), 5 mm (3/16 in.), 6 mm(7/32 in.), 8 mm (5/16 in.)

. VMPB/FPKA pole mounting kit (8 mm)

. EMIA installation (4 mm, 5 mm, 6 mm)

. Feederless sites (grounding kit) (5 mm)

Thread locking compound (medium strength, non-permanent),for example Loctite 242 or equivalent

. Installation on a pole or wall

. FMSA

Vacuum cleaner or broom with dust pan EMIA installation

Saw Feederless sites

Heat gun for cable shrinking sleeves Feederless sites

A.2 Torque values

Nokia Siemens Networks strongly recommends that you tighten to thefollowing torque values. These values assume the use of a lubricated boltor fastener. Use these values unless stated otherwise.

Figure 30. Torque wrench

DN70234447

62 (63) # Nokia Siemens Networks DN7064519Issue 3 en18/06/2008

Installing Flexi Cabinet for Indoor (FCIA)

Page 63: Dn7064519_Installing Flexi Cabinet for Indoor

Table 5. Torque values for the BTS

Size Type Usage Torque

M3 Screw, TORX pan head EMIA 1.5-2.0 Nm (1.11-1.47 ft-lb)

M4 Screw, TORX cylinderhead

FCSA and FCFA fans 1.2 - 1.6 Nm (0.9 - 1.2 ft-lb)

M4 Screw, TORX pan heador thumb (knurled head)

. EWxx and FIxA installation

. ESMA, EXxA, ECxA, ESEA, andFPDA fan plate assembly

. FMAA

2.7-3.3 Nm (1.99-2.43 ft-lb)

M5 Screw, TORX thumb(knurled head) or panhead

EMxA front and rear covers 2.0 - 2.5 Nm (1.5-1.8 ft-lb)

M5 Screw, TORX pan heador thumb (knurled head)

. EMxA casings and cable entries

. Mounting modules

. Auxiliary boxes

. EMIA

. Module grounding

. FCIA site grounding (NEBS)

. FMAA

3.5-4.2 Nm (2.58-3.10 ft-lb)

M5 Nut, Hex FCOA site grounding 3 Nm

M5 Screw, slotted flathead . EMIA. Module grounding

3.5-4.2 Nm (2.58-3.10 ft-lb)

M6 Screw, Allen or TORXhead

. EMIA

. FMAA

4.2-5.8 Nm (3.1-4.28 ft-lb)

M6 Nut, Hex EMIA 4.2-5.5 Nm (3.1-4.05 ft-lb)

M8 Screw, TORX or hexhead

FCIA/EMIA/plinth site grounding 8.0-10.0 Nm (5.9-7.37 ft-lb)

M8 Nut, Hex FCOA site grounding 5 Nm

M8 Screw, hex head Plinth adapter mechanics 10.0 Nm (7.37 ft-lb)

M10 Nut, Hex ESMA, ESEA, FPDA and EOCA DCpower terminals

10.0 - 14.0 Nm (7.0 - 9.8ft -lb)

M10 Bolt, Allen head VMPB/FPKA pole mounting kits 29 Nm (21.4 ft-lb)

M12 (15/32in.)

Anchoring bolts Anchoring FCIA/FCOA/FMFA to floor(not included in Flexi EDGE delivery)

49.0 Nm (36.1 ft-lb)

7/16 DIN Antenna connector Antenna jumper cables (not includedin Flexi EDGE delivery)

25 Nm (18.5 ft-lb

DN7064519Issue 3 en18/06/2008

# Nokia Siemens Networks 63 (63)

Installation tools and torque values


Recommended