DUAL VIEW ICP-OES MINUS THE WAIT Agilent 5100 ICP-OES The fastest ICP-OES... ever. The Agilent 5100 Synchronous Vertical Dual View (SVDV) ICP-OES revolutionizes ICP-OES analysis. With its unique Dichroic Spectral Combiner (DSC) technology, you can now run axial and radial view analysis at the same time. Save time and money Run the fastest ICP-OES analysis, using less gas. Measure all wavelengths in one measurement, for higher precision without delays. Start work sooner with the zero gas consumption VistaChip II detector that shortens warm-up time. Uncompromised performance Measure your toughest samples with a vertical torch. Achieve long term analytical stability with a solid-state RF system. Simplify your analysis Take the guess work out of method development with intuitive ICP Expert software and DSC technology. Powerful software algorithms simplify method development, improve accuracy, and extend your measurement range. Flexible configurations The Agilent 5100 is available in three configurations: Synchronous Vertical Dual View. Vertical Dual View. Radial View. ROBUST AND STABLE With a vertical torch and robust solid state RF in every configuration, the 5100 ICP-OES handles your toughest samples with ease. Shown is the percentage readback on a range of elements in a 25% NaCl solution. Readback stability for all elements over 4 hours was < 1.3% RSD, without internal standardization. 60 AI 396.152 As 188.980 Ba 455.403 Cd 214.439 Co 238.892 80 100 120 0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 4:00 % Readback Time (h:mm) Cr 267.716 Mn 257.610 Mo 202.032 Ni 231.604 Pb 220.353 Se 196.026 Sr 407.771 Cu 327.395 Zn 213.857 0 20 40 Agilent 5100 ICP-OES 4 hour stability in 25% NaCI
Transcript
Page 1: DUAL VIEW ICP-OES MINUS THE WAIT - Agilent · DUAL VIEW ICP-OES MINUS THE WAIT Agilent 5100 ICP-OES The fastest ICP-OES... ever. The Agilent 5100 Synchronous Vertical Dual View (SVDV)

DUAL VIEW ICP-OES MINUS THE WAIT

Agilent 5100 ICP-OES

The fastest ICP-OES... ever.

The Agilent 5100 Synchronous Vertical Dual View (SVDV) ICP-OES revolutionizes ICP-OES analysis. With its unique Dichroic Spectral Combiner (DSC) technology, you can now run axial and radial view analysis at the same time.

Save time and money

• Run the fastest ICP-OES analysis,

using less gas.

• Measure all wavelengths in one

measurement, for higher precision

without delays.

• Start work sooner with the zero gas

consumption VistaChip II detector that

shortens warm-up time.

Uncompromised performance

• Measure your toughest samples with

a vertical torch.

• Achieve long term analytical stability

with a solid-state RF system.

Simplify your analysis

• Take the guess work out of method

development with intuitive ICP Expert

software and DSC technology.

• Powerful software algorithms simplify

method development, improve accuracy,

and extend your measurement range.

Flexible confi gurations

The Agilent 5100 is available in three

confi gurations:

• Synchronous Vertical Dual View.

• Vertical Dual View.

• Radial View.

ROBUST AND STABLEWith a vertical torch and robust solid state

RF in every confi guration, the 5100

ICP-OES handles your toughest samples

with ease.

Shown is the percentage readback on a range of

elements in a 25% NaCl solution. Readback stability

for all elements over 4 hours was < 1.3% RSD,

without internal standardization.

60

AI 396.152 As 188.980 Ba 455.403 Cd 214.439 Co 238.892

80

100

120

0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 4:00

% R

eadback

Time (h:mm)

Cr 267.716

Mn 257.610 Mo 202.032 Ni 231.604 Pb 220.353 Se 196.026 Sr 407.771

Cu 327.395

Zn 213.8570

20

40

Agilent 5100 ICP-OES4 hour stability in 25% NaCI

Page 2: DUAL VIEW ICP-OES MINUS THE WAIT - Agilent · DUAL VIEW ICP-OES MINUS THE WAIT Agilent 5100 ICP-OES The fastest ICP-OES... ever. The Agilent 5100 Synchronous Vertical Dual View (SVDV)

Axial light

Vertical

torch and

plasma

Dichroic Spectral

Combiner (DSC)

Radial light

To detector

This information is subject to change without notice.

© Agilent Technologies, Inc. 2014Published July 1, 2014

5991-4835EN

For more information: Contact your local Agilent

representative or visit:

www.agilent.com/chem/5100icpoes

DID YOU KNOW?

Conventional dual view ICP-OES systems require you to set up

a series of sequential measurements by selecting which

elements are measured in axial mode and which are measured

in radial mode.

Some systems also use two slits to measure low and

high wavelengths in each mode, resulting in up to four

sequential measurements on each sample, making sample

throughput slow.

1. The analysis speed and gas consumption

fi gures are compared to competitive systems,

based on published application data. Refer to

Agilent application note 5991-4821EN

The 5100 SVDV ICP-OES needs only a single measurement per sample. The Dichroic Spectral Combiner allows both the axial and radial views of the plasma to be captured in one reading. This delivers accurate results in the quickest possible time1.

5055

%

%

LESS ARGON

FASTER

How does Synchronous Vertical

Dual View work?

20 L

5100 V

DV

27 L

SC

D &

CID

DV

sys

tem

s

> 40 L

5100 S

VD

V

Dramatically reduce your argon

consumption1

The 5100 ICP-OES has the lowest

argon consumption per sample of any

ICP-OES instrument.


Recommended