+ All Categories
Home > Documents > DUNE CRYO WIB MODS2 - University of Hawaiiidlab/taskAndSchedule/DUNE/DUNE C… · cmd femb 1 cmd...

DUNE CRYO WIB MODS2 - University of Hawaiiidlab/taskAndSchedule/DUNE/DUNE C… · cmd femb 1 cmd...

Date post: 18-Jul-2020
Category:
Upload: others
View: 2 times
Download: 0 times
Share this document with a friend
13
DUNE CRYO WIB Modifications BNL Team 1/23/2019
Transcript
Page 1: DUNE CRYO WIB MODS2 - University of Hawaiiidlab/taskAndSchedule/DUNE/DUNE C… · cmd femb 1 cmd femb 2 cmd femb 3 cmd sy898 47 to femb data cable femb 0 clk femb 1 clk femb 2 clk

DUNE CRYO WIBModificationsBNL Team 1/23/2019

Page 2: DUNE CRYO WIB MODS2 - University of Hawaiiidlab/taskAndSchedule/DUNE/DUNE C… · cmd femb 1 cmd femb 2 cmd femb 3 cmd sy898 47 to femb data cable femb 0 clk femb 1 clk femb 2 clk

Modifications to ProtoDUNE WIB

• FEMB Clock distribution• Two clocks distributed to each FEMB bypassing FPGA

• FEMB Power • A linear regulator add to feed power down to FEMB

• FEMB communication• Two IO Signals added to FEMB data cable

2

Page 3: DUNE CRYO WIB MODS2 - University of Hawaiiidlab/taskAndSchedule/DUNE/DUNE C… · cmd femb 1 cmd femb 2 cmd femb 3 cmd sy898 47 to femb data cable femb 0 clk femb 1 clk femb 2 clk

3

SI5344 SY58608

PLL Jitter Cleaner

1:2FANOUT

To FPGA

SY89832From FPGA

To FEMB DATA CABLEFEMB 0

CMD

FEMB 1CMD

FEMB 2CMD

FEMB 3CMD

SY89847

To FEMB DATA CABLEFEMB 0

CLK

FEMB 1CLK

FEMB 2CLK

FEMB 3CLK

From FPGA

Not Used

DUNE CLK DUNE CLK

ProtoDUNE WIB CLOCK DISTRIBUTION

1:5FANOUT

1:4FANOUT

Page 4: DUNE CRYO WIB MODS2 - University of Hawaiiidlab/taskAndSchedule/DUNE/DUNE C… · cmd femb 1 cmd femb 2 cmd femb 3 cmd sy898 47 to femb data cable femb 0 clk femb 1 clk femb 2 clk

4

SI5344

SY89832

PLL Jitter Cleaner

To FPGA

Not Used

SY89847

From FPGA

To FEMB DATA CABLEFEMB 0

CMD

FEMB 1CMD

FEMB 2CMD

FEMB 3CMD

SY89847

To FEMB DATA CABLEFEMB 0

CLK

FEMB 1CLK

FEMB 2CLK

FEMB 3CLK

From FPGA

Not Used

Not Used

DUNE CLK DUNE CLK

DUNE CLK

1:2FANOUT

1:5FANOUT

1:5FANOUT

DUNE CRYO WIB CLOCK DISTRIBUTION

Page 5: DUNE CRYO WIB MODS2 - University of Hawaiiidlab/taskAndSchedule/DUNE/DUNE C… · cmd femb 1 cmd femb 2 cmd femb 3 cmd sy898 47 to femb data cable femb 0 clk femb 1 clk femb 2 clk

ProtoDUNE WIB POWER

5

LTM4644

DC2DC

DC2DC

DC2DC

DC2DC

DC2DC LTM8029

LDOTPS73201

2.5V @ 140mA

2.5V @ 1A

2.5V @ 1A

2.5V @ 1A

LDO 2.5V @ 1ATPS74401

2.65V @ 1A

3.3V

2.65V

Page 6: DUNE CRYO WIB MODS2 - University of Hawaiiidlab/taskAndSchedule/DUNE/DUNE C… · cmd femb 1 cmd femb 2 cmd femb 3 cmd sy898 47 to femb data cable femb 0 clk femb 1 clk femb 2 clk

DUNE CRYO WIB POWERScheme 1

6

LTM4644

DC2DC

DC2DC

DC2DC

DC2DC

DC2DC LTM8029

LDOTPS73201

2.5V @ 100mA

2.5V @ 1A

2.5V @ 1A

LDO 2.5V @ 1A

LDO 2.5V @ 1A

TPS74401

TPS74401

2.65V @ 1A

3.3V

2.65V

2.65V

Page 7: DUNE CRYO WIB MODS2 - University of Hawaiiidlab/taskAndSchedule/DUNE/DUNE C… · cmd femb 1 cmd femb 2 cmd femb 3 cmd sy898 47 to femb data cable femb 0 clk femb 1 clk femb 2 clk

DUNE CYRO FEMB POWERConnector

• Samtec Power cables

7

Total combined current Should not exceed 140mA

Page 8: DUNE CRYO WIB MODS2 - University of Hawaiiidlab/taskAndSchedule/DUNE/DUNE C… · cmd femb 1 cmd femb 2 cmd femb 3 cmd sy898 47 to femb data cable femb 0 clk femb 1 clk femb 2 clk

DUNE CRYO WIB POWERScheme 2

8

LTM4644

DC2DC

DC2DC

DC2DC LTM8029

LDO

LDO

LDO

5.5V

Front Pannel

FUSE

FUSE

FUSE

FUSE

DC2DC

DC2DC

FEMB

ADJ V@ 2.5A

V+ Sense

V- Sense

5 V@ 100mA

Page 9: DUNE CRYO WIB MODS2 - University of Hawaiiidlab/taskAndSchedule/DUNE/DUNE C… · cmd femb 1 cmd femb 2 cmd femb 3 cmd sy898 47 to femb data cable femb 0 clk femb 1 clk femb 2 clk

DUNE CYRO FEMB POWERConnector

• Samtec Power cables

9

Total combined current Should not exceed 140mA

Total combined current Should not exceed 2.5A

Page 10: DUNE CRYO WIB MODS2 - University of Hawaiiidlab/taskAndSchedule/DUNE/DUNE C… · cmd femb 1 cmd femb 2 cmd femb 3 cmd sy898 47 to femb data cable femb 0 clk femb 1 clk femb 2 clk

Signals Added to FEMB Cold Data Cable

10

Not connected to FPGA

Connected to FPGA

Connected to FPGADIFF Pairs

Page 11: DUNE CRYO WIB MODS2 - University of Hawaiiidlab/taskAndSchedule/DUNE/DUNE C… · cmd femb 1 cmd femb 2 cmd femb 3 cmd sy898 47 to femb data cable femb 0 clk femb 1 clk femb 2 clk

DUNE CYRO FEMB Cold DataConnector

11

TX Data 0

TX Data 1

TX Data 2

TX Data 3

FPGA IO

FPGA IO

FPGA IO

FPGA IO

FPGA IO

FPGA IO

CLK 0

CLK 1

LVDS

LVDS

LVDS

LVDS

LVDS

LVDS

LVDS pairsswapped

Page 12: DUNE CRYO WIB MODS2 - University of Hawaiiidlab/taskAndSchedule/DUNE/DUNE C… · cmd femb 1 cmd femb 2 cmd femb 3 cmd sy898 47 to femb data cable femb 0 clk femb 1 clk femb 2 clk

12

Page 13: DUNE CRYO WIB MODS2 - University of Hawaiiidlab/taskAndSchedule/DUNE/DUNE C… · cmd femb 1 cmd femb 2 cmd femb 3 cmd sy898 47 to femb data cable femb 0 clk femb 1 clk femb 2 clk

13


Recommended