DRAWING NO: ISSUE: DRAWING TITLE: JOB NO: PROJECT: PROJECT LOCATION: CLIENT: SCALE: CHECKED BY: DRAWN BY: PROJECT DESIGNER: GENERAL NOTES: THIS DESIGN & DOCUMENTATION REMAIN THE PROPERTY OF MECHANICAL DRAFTERS SERVICES . NO REPRODUCTION & OR ALTERATIONS ARE PERMITTED WITHOUT THE WRITTEN PERMISSION OF MECHANICAL DRAFTERS SERVICES . ALL WORKS ARE TO COMPLY WITH THE FOLLOWING: • BUILDING CODE OF AUSTRALIA • THE QUEENSLAND BUILDING ACT • ALL RELEVANT LOCAL AUTHORITIES, BY-LAWS & PLANNING SCHEMES. © COPYRIGHT-REPRODUCTION IN WHOLE OR PART IS STRICTLY PROHIBITED WITHOUT PERMISSION ISSUE AMENDMENT DATE DATE DRAWN: DD DANIEL DOLHARE DD DESIGN: DRAWING LIST DRAWING No DRAWING TITLE DATE DRAWN REVISION MECHANICAL DRAFTERS SERVICES A.B.N: 651 856 035 12 DDAD Pty. Ltd atf. Trading as PO Box 1613 Runaway Bay 4216 Queensland, Australia E: [email protected] W: www.mechanicaldrafters.com.au -THESE PLANS ARE NOT TO BE USED FOR ENGINEER, ARCHITECTURAL OR CONSTRUCTION PURPOSE RAINWATER GUTTERS 1-QUAD SLOTTED GUTTERS FIXED TO METAL FASCIA, GUTTER TO FALL TO 90mm DOWNPIPES SPACED AS SHOWN AND FIXED TO WALL. 2-FASCIA & GUTTER SHALL BE COLOBOND AS PER CONTRACT. 3-DOWNPIPE TO BE PAINTED PVC. TERMITE CONTROL 1-TERMITE CONTROL TO BE IN ACCORDANCE WITH A.S. 3660. 1-2000 & BCA HOUSING PROVISIONS PART 3,1,3- TERMITE RISK MANAGEMENT. 2-TERMITE PROTECTION PER BUILDER SPECIFICATION. 3-TERMITE SYSTEM TO BE INSPECTED & MAINTENED AS ADVISED BY INSTALLERS, MANUFACTURER OR EVERY 12 MONTHS WHICHEVER IS THE LESSER. INSPECTIONS TO BE CARRIED OUT BY COMPETENT PERSONS. 4-TWO DURABLE NOTICE ARE TO BE FIXED BY BUILDER IN A PROMINENT PLACE, (E.G. METER BOX & KITCHEN CUPBOARD) NOTICE IS TO SHOW, METHOD OF PROTECTION, DATE OF INSTALLATION AND MANUFACTURER'S RECOMENDATION FOR FUTURE INSPECTIONS. 5-BUILDER TO DISCUSS & ADVISE OWNER / CLIENT ON METHOD OF TERMITE CONTROL TO ENSURE UNDERSTANDING OF OWNER OBLIGATIONS. 6-CONCRETE SLAB & FOUNDATIONS ARE TO BE DESIGNED & CONSTRUTED IN ACCORDANCE WITH A.S. 2870. HOT WATER SERVICE 1-COLD WATER SRVICE LEADING TO HWS TO BE RO.3 LAGGED FOR FIRST 500mm OUT FROM HWS. 2-HOT WATER SERVICE LEADING FROM HWS TO ALL FIXTURES TO BE RO.3 LAGGED FOR ALL EXPOSED PIPEWORK ADJACENT TO HWS & ALL PIPEWORK IN ROOF VOID EXCEPT FOR ROOFS WITH INSULATION BLANKET / BATTS UNDER ROOFING MATERIAL. LEGEND CJ CONSTRUCTION JOINT DP DOWNPIPE FP FIRE PLACE FW FLOOR WASTE HWS HOT WATER SYSTEM AC AIR CONDITIONING PS PLUMBING STACK/DUCT SP STEEL POST TBC TO BE CONFIRMED RL RELATIVE LEVEL AHD AUSTRALIAN HEIGHT DATUM CSD CAVITY SLIDING DOOR OHC OVER HEAD CUPBOARD FG FIXED GLASS FSR FLOOR SPACE RATIO LB LOAD BEARING NGL NATURAL GROUND LINE UBO UNDER BENCH OVEN WO WALL OVEN DW DISHWASHER MW MICROWAVE WM WASHING MACHINE WIR WALK-IN ROBE SD SLIDING GLASS DOOR AAW ALUMINIUM AWNING WINDOW ADH ALUMINIUM DOUBLE HUNG WINDOW AAW ALUMINIUM AWNING WINDOW ALW ALUMINIUM LOUVRE WINDOW BCA BUILDING CODE OF AUSTRALIA AS AUSTRALIAN STANDARDS GENERAL NOTES DO NOT SCALE PLANS, USE WRITTEN DIMENSIONS ONLY. 1-ALL CONSTRUCTION SHALL CONFORM STRICTLY WITH THE REQUIREMENTS OF THE BUILDING CODE OF AUSTRALIA, THE QUEENSLAND BUILDING ACT 1975-1990 TOGETHER WITH BUILDING AMENDMENTS ACT 1991, THE QUEENSLAND DEVELOPMENT CODE AND ANY AMENDMENTS & ATTACHMENTS AS PUBLISH. 2-ALL MATERIALS USED FOR CONSTRUCTION WORK COVERED BY THESE PLANS SHALL BE NEW AND TOP QUALITY. 3-ALL TIMBER CONSTRUCTIONS SHALL BE IN ACCORDANCE WITH A.S. 1684.2-2010 RESIDENTIAL TIMBER FRAMED CONSTRUCTION. 4-ALL DIMENSIONS AND LEVELS MUST BE CHECKED BY BUILDER PRIOR TO COMMENCE OF WORK, ON OR OFF SITE. 5-ALL WET AREAS TO COMPLY WITH A.S. 3740-2004. 6-WC DOORS OPENING INWARDS TO BE FITTED WITH LIFT-OFF HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN IN CLOSED POSITION. BRICK WORK 1-110mm BLOCKWORK ATTACHED TO FRAME WITH APPROVED TIES SPACED HORIZONTALLY AND VERTICALLY TO A.S. 3700. FLASHING / DAMP COURSE TO BE PLACED BELOW FLOOR SLAB LEVEL TO PERIMETER OF BUILDING. WEEP HOLES TO BE PLACED EVERY 900mm CENTRE HORIZONTALLY AT DAMP COURSE LEVEL AND AT OTHER LEVELS WHERE THERE IS HORIZONTAL FLUSHING. 2-ALL BLOCKWORK BRICK TIES & MORTAR IS TO BE TO A.S. 370. 3-ALL WINDOWS & DOORS IN BLOCKWORK TO HAVE FLASHING & BRICK SILLS. JOINERY 1-ALL JOINERY TO BE ALUMINIUM FRAMED WITH POWDECOASTING TO CONFORM TO A.S. 2047 & A.S. 1288. 2-NO LOAD IS TO BEAR ON FRAMES. 3-KEEP ALL FRAMES & GLAZING CLEAR OF CONCRETE, MORTAR & SOLVENTS. 4-ALL SLIDING GLASS DOORS SHALL BE WITHOUT MID-RAILS. 5-ALL HINGED DOORS (INCLUDING FRONT DOOR) TO BE AS NOMINATED ON CONTRACT. LINING 1-INTERNAL LINING TO BE PLASTERBOARD, 10mm TO WALLS & 13mm OR 10mm ABLE TO SPAN 600mm TO CEILINGS. 2-10mm GAP TO BE LEFT BETWEEN FLOOR & SHEETING. 3-FIXING, CONTRACTION JOINT LOCATIONS & LEVEL OF FINISH IS TO BE AS PER A.S./N.Z. 2589-1-1997 OR MANUFACTURE'S. SPECIFICATION. 4-CORNICE TYPES AS PER CONTRACT. 5-WET AREA LINING TO BE VILLABOARD OR SIMILAR APPROVED WATER RESISTANT GRADED LINING. SOFFIT LININGS 1-SOFFITS ARE TO BE BATTENED WITH 38 X 50 LOSP TREATED TIMBER & SHEETED WITH HARDITEX 4.5mm F.C. SHEETING. ROOF FRAMEWORK 1-POST FABRICATED TRUSSES AT NOMINATED PITCH ON PLANS & 600mm CENTRES. 2-ENTIRE ROOF TO BE TRUSS CONSTRUCTIONS UNLESS INDICATED OTHERWISE ON FLOOR/FRAMING PLAN. 3-TRUSSES TO BE ENGINEER DESIGNED, FIXED & BRACED AS PER THE MANUFACTURE'S REQUIREMENTS. 4-THE TRUSS MANUFACTURER SHALL PROVIDE ALL NECESSARY DOCUMENTTION & CERTIFICATION AS REQUIRED FOR THE CONSTRUCTION / ERECTION OF THE ROOF FRAMING AND THE APPROVAL BY COUNCIL / PRIVATED CERTIFIER. 5-WHERE TRUNCATED & GIRDER TRUSSES OCCUR THE TRUSS MANUFACTURER IS TO CHECK THE ADEQUACY OF LINTELS SUPPORTING THEM AND THE TIE-DOWN REQUIREMENTS. 6-TRUSS MANUFACTURER MUST NOTIFY BUILDER OFANY CHANGE TO LINTEL OR TIE-DOWN DESIGN AT TRUSS DESIGN STAGE. 7-TRUSS MANUFACTURER TO NOMINATE THE NUMBER OF STUDS REQUIRED UNDER TRUNCATED & GIRDER TRUSSES. 8-BOTTOM CHORD BINDERS AS PER TRUSS MANUFATURER'S SPEC. & AT MAXIMUM 3000mm CENTRES. 9-PINE TOP PLATES UNDER TRUNCATED & GIRDER TRUSSES TO HAVE THE RIBBON PLATE REPLACED WITH F17 KDH PLATE OF SAME SIZE. KDH PLATE IS TO SPAN MINIMUM OF 3STUDS & CENTRALLY LOCATED UNDER TRUSS. 10-ROOFING MATERIAL TO BE FIXED TO MANUFACTURER'S SPECIFICATIONS FOR TERRAIN CATEGORY, PROFILE & FINISH AS PER CONSTRACT. ROOFING 1-NOMINATED ROOFING ON PLANS, TO BE FIXED AS NOMINATED IN ACCORDANE WITH MANUFACTURER'S SPECIFICATION. QLD SUSTAINABLE HOUSE CODE SHOWER ROSE SHOWER ROSE TO BE AAA RATING ASSESSED AGAINST AS / NZ 6400-2004 OR A3 STAR RATING UNDER THE WATER EFFICIENCY LABELLING SCHEME (WELS). TOILET CISTERNS TOILET CISTERNS TO HAVE DUAL FLUSH CAPACITY THAT DOES NOT EXCEED 6 Lts. ON FULL FLUSH & 3 Lts. ON HALF FLUSH. WATER SUPPLY WHERE MAIN WATER POSTSSURE AT THE OUTLED WITHIMTHE BOUNDARY EXCEEDS 500Kpa.A WATER POSTSSURE LIMITING DEVICE TO BE INSTALLED TO ENSURE POSTSSURE REMAINS BELOW 500Kpa. PLUMBING NOTES 1-ALL DRAINAGE AND PLUMBING WORK MUST BE CARRIED OUT BY A LICENCED PLUMBER / DRAINER ONLY AND STRICTLY IN ACCORDANCE WITH "THE STANDARD SEWERAGE BY-LAWS". NOT WORK SHALL BE COVERED UO UNTIL IT HAS BEEN EXAMINED & PASSED BY THE COUNCIL'S SPECIFICATION. 2-DISCHARGE ALL WASTERS TO SEWERAGE SYSTEMS IN ACCORDANCE WITH THE LOCAL COUNCIL'S SPECIFIATION. 3-DISCHARGE ROOF WATER DRAINAGE TO STORMWATER CONNECTION POINT AS PER COUNCIL'S REQUIREMENT. 4-ROOFING CONTRACTOR & PLUMBER TO ENSURE THAT THE NUMBER OF DOWNPIPES SHOWN ON PLAN IS ADEQUATE & LOCATED IN THE OPTIMUM POSITIONS. 5-SEWER HOUSE CONNECTION & MAIN LOCATION TO BE CONFIRMED WITH LOCAL AUTHORITY PRIOR TO CONSTRUCTION. UNDERGROUND SERVICE LOCATIONS ARE APPROXIMATE ONLY & SHOULD BE VERIFIED BY LOCAL AUTHORITY PRIOR TO CONSTRUCTION. HOT WATER PROVIDE GAS HOT WATER SYSTEM, APPROVED ELECTRICAL HEAT PUMP SYSTEM OR SOLAR HOT WATER SYSTEM WITH A FIVE START ENERGY RATING. SITE NOTES 1-DETAIL OF CUT & FILL REQUIREMENTS FOR THIS BUILDING SITE IS BASED ON SURFACE LEVELS TAKEN ON THE OWNER/BUILDER SPECIFIED REQUIREMENTS. SUCH DETAIL IS SUBJECT TO VARIATION DEPENDENT UPON GROUND CONDITIONS ENCOUNTERED, SOIL TEST RESULTS & LOCAL AUTHORITY REQUIREMENTS. 2-CLEAR BUILDING AREA OF ALL VEGETATION TO ONE METRE PATH THE BUILDING PEREMITER. REMOVE ALL STUMPS & ROOTS. STOCKPILE TOP SOIL FOR RE-USE ON COMPLETION OF BUILDING CONSTRUCTION. TOP SOIL IS NOT TO BE USED AS FILL MATERIAL. 3-ALL CUT & FILL EMBANKMENTS TO BE NO STEEPER THAN 1:2 AND ALL DRIVEWAY TO BE NO STEEPER THAN 1:6. ALL EARTHWORKS TO BE IN ACCORDANCE TO A.S. 2870. 4-SLOPE BUILDING PAD TO DRAIN AWAY FROM RESDENCE AND TO NATURAL GROUND FALL. 5-SITE WORK INDICATED ON THIS PLAN ARE FOR CONSTRUCTION ONLY. IT IS THE CLIENT RESPONSABILITY TO CARRY OUT ALL LANDSCAPING, SITE DRAINAGE, RETAINING WALLS AFTER COMPLETION OF CONSTRUCTION. ALL RETAINING WALLS & EMBANKMENTS SHOWN ARE TO COMPLY WITH THE LOCAL AUTHORITIES POLICY FOR RETAINING WALLS & EMBANKMENTS ON RESIDENTIAL BUILDING SITES, POSITION OF RETAINING WALLS & EMBANKMENTS MAY VARY ACCORDING TO SITE WORKS. 6-LEVEL OF CONCRETE FLOOR SLAB TO DWELLING IS TO BE VERIFIED BY BUILDER TO ENSURE THAT A MINIMUM HEIGHT ABOVE FINISHED GROUND LEVEL IS ATTAINED IN ACORDANCE TO THE B.C.A. QLD BUILDING ACT-AMMENDMENT ACT 1991 & LOCAL AUTHORITY POLICY AND CONFIRM CUT & FILL LEVELS. 7-BUILDER TO VERIFY THE LOCATION OF ALL SERVICES PRIOR TO CONSTRUCTION. 8-CONFIRM THAT ALL SURVEY PEGS ARE IN THE CORRECT POSITION BEFORE SETTING OUT THE BUILDING, IF ANY DOUBT ARISES CONTACT THEBUILDER/SURVEYOR. 9-AFTER COMPLETION OF CONSTRUCTION OF THE DWELLING, THE OWNER SHALL MAINTAIN THE SITE & DWELLING IN ACCORDANCE WITH THE C.S.I.R.O. LEAFLET SHEET No 10-91 " GUIDE TO HOME OWNERS ON FOUNDATION MAINTENANCE AND FOOTING PERFORMANCE". 10-DO NOT SCALE DIMENSIONS OFF PLAN. FIGURED DIMENSIONS TO BE USED AT ALL TIMES. NOTES : DRAWING SYMBOLS USED ON THIS DRAWING MAY NOT BE TRUE REPOSTSENTATION OF ITEMS TO INCLUDE IN CONTRACT. REFER TO CONTRACT FOR SPECIFIED ITEMS. @ A3 A WD-00 TITLE PAGE 479- WD 19 DUAL OCCUPANCY - FOR PEOPLE WITH DISABILITIES 479- WD 19 DUAL OCCUPANCY - FOR PEOPLE WITH DISABILITIES 479- WD 19 DUAL OCCUPANCY - FOR PEOPLE WITH DISABILITIES 02/11/2016 CUSTOM TURNKEY HOME WD-00 TITLE PAGE 02/11/2016 A WD-01 ART IMPRESSION 02/11/2016 A WD-03 GROUND FLOOR PLAN 02/11/2016 A WD-04 NAVIGATION & MANOEUVRE PLAN 02/11/2016 A WD-05 ROOF PLAN 02/11/2016 A WD-06 FRONT & LEFT ELEVATIONS 02/11/2016 A WD-07 BACK & RIGHT ELEVATIONS 02/11/2016 A WD-08 CONCRETE SETOUT PLAN 02/11/2016 A WD-09 PENETRATION PLAN 02/11/2016 A WD-10 ELECTRICAL PLAN 02/11/2016 A WD-11 KITCHEN FLOOR PLAN & ELEVATIONS 02/11/2016 A WD-12 KITCHEN FLOOR PLAN & ELEVATIONS 02/11/2016 A WD-13 ENSUITE FLOOR PLAN & ELEVATIONS 02/11/2016 A WD-14 BATHROOM FLOOR PLANS & ELEVATIONS 02/11/2016 A WD-15 L'DRY PLANS & ELEVATIONS 02/11/2016 A WD-16 NAVIGATION PLANS WET AREAS 02/11/2016 A WD-17 MARKETING FLOOR PLAN 02/11/2016 A WD-18 BUILDING DETAILS 02/11/2016 A WD-19 BUILDING DETAILS 02/11/2016 A A WORKING DRAWING 02/11/2016
Transcript
Page 1: D:YOARQUITECTURAAA-MECHANICAL DRAFTERAAA …disabilityhousingsolutions.com.au/properties/wp...termite control 1-termite control to be in accordance with a.s. 3660. 1-2000 & bca housing

DRAWING NO: ISSUE:

DRAWING TITLE:

JOB NO:

PROJECT:

PROJECT LOCATION:

CLIENT:

SCALE:

CHECKED BY:

DRAWN BY:

PROJECT DESIGNER:

GENERAL NOTES:THIS DESIGN & DOCUMENTATION REMAIN THEPROPERTY OF MECHANICAL DRAFTERS SERVICES.NO REPRODUCTION & OR ALTERATIONS ARE PERMITTEDWITHOUT THE WRITTEN PERMISSION OFMECHANICAL DRAFTERS SERVICES.

ALL WORKS ARE TO COMPLY WITH THE FOLLOWING:• BUILDING CODE OF AUSTRALIA• THE QUEENSLAND BUILDING ACT• ALL RELEVANT LOCAL AUTHORITIES, BY-LAWS &PLANNING SCHEMES.

© COPYRIGHT-REPRODUCTION IN WHOLE OR PART ISSTRICTLY PROHIBITED WITHOUT PERMISSION

ISSUE AMENDMENT DATE

DATE DRAWN:

DD

DANIEL DOLHARE

DD

DESIGN:

DRAWING LIST

DRAWING No DRAWING TITLE DATE DRAWN REVISION

MECHANICAL DRAFTERS SERVICES

A.B.N: 651 856 035 12DDAD Pty. Ltd atf.Trading as

PO Box 1613 Runaway Bay 4216Queensland, AustraliaE: [email protected]: www.mechanicaldrafters.com.au

-THESE PLANS ARE NOT TO BE USED FOR ENGINEER, ARCHITECTURAL OR CONSTRUCTION PURPOSE

RAINWATER GUTTERS1-QUAD SLOTTED GUTTERS FIXED TO METAL FASCIA, GUTTER TO FALL TO 90mm DOWNPIPES SPACED AS SHOWNAND FIXED TO WALL.

2-FASCIA & GUTTER SHALL BE COLOBOND AS PER CONTRACT.

3-DOWNPIPE TO BE PAINTED PVC.

TERMITE CONTROL1-TERMITE CONTROL TO BE IN ACCORDANCE WITH A.S. 3660. 1-2000 & BCA HOUSING PROVISIONS PART 3,1,3-TERMITE RISK MANAGEMENT.

2-TERMITE PROTECTION PER BUILDER SPECIFICATION.

3-TERMITE SYSTEM TO BE INSPECTED & MAINTENED AS ADVISED BY INSTALLERS, MANUFACTURER OR EVERY 12 MONTHSWHICHEVER IS THE LESSER.INSPECTIONS TO BE CARRIED OUT BY COMPETENT PERSONS.

4-TWO DURABLE NOTICE ARE TO BE FIXED BY BUILDER IN A PROMINENT PLACE, (E.G. METER BOX & KITCHEN CUPBOARD)NOTICE IS TO SHOW, METHOD OF PROTECTION, DATE OF INSTALLATION AND MANUFACTURER'S RECOMENDATION FORFUTURE INSPECTIONS.

5-BUILDER TO DISCUSS & ADVISE OWNER / CLIENT ON METHOD OF TERMITE CONTROL TO ENSURE UNDERSTANDING OFOWNER OBLIGATIONS.

6-CONCRETE SLAB & FOUNDATIONS ARE TO BE DESIGNED & CONSTRUTED IN ACCORDANCE WITH A.S. 2870.

HOT WATER SERVICE

1-COLD WATER SRVICE LEADING TO HWS TO BE RO.3 LAGGED FOR FIRST 500mm OUT FROM HWS.

2-HOT WATER SERVICE LEADING FROM HWS TO ALL FIXTURES TO BE RO.3 LAGGED FOR ALL EXPOSED PIPEWORK ADJACENTTO HWS & ALL PIPEWORK IN ROOF VOID EXCEPT FOR ROOFS WITH INSULATION BLANKET / BATTS UNDER ROOFING MATERIAL. LEGEND

CJ CONSTRUCTION JOINTDP DOWNPIPEFP FIRE PLACEFW FLOOR WASTEHWS HOT WATER SYSTEMAC AIR CONDITIONINGPS PLUMBING STACK/DUCTSP STEEL POSTTBC TO BE CONFIRMEDRL RELATIVE LEVELAHD AUSTRALIAN HEIGHT DATUMCSD CAVITY SLIDING DOOROHC OVER HEAD CUPBOARDFG FIXED GLASSFSR FLOOR SPACE RATIOLB LOAD BEARINGNGL NATURAL GROUND LINEUBO UNDER BENCH OVENWO WALL OVENDW DISHWASHERMW MICROWAVEWM WASHING MACHINEWIR WALK-IN ROBESD SLIDING GLASS DOORAAW ALUMINIUM AWNING WINDOWADH ALUMINIUM DOUBLE HUNG WINDOWAAW ALUMINIUM AWNING WINDOWALW ALUMINIUM LOUVRE WINDOWBCA BUILDING CODE OF AUSTRALIAAS AUSTRALIAN STANDARDS

GENERAL NOTESDO NOT SCALE PLANS, USE WRITTEN DIMENSIONS ONLY.

1-ALL CONSTRUCTION SHALL CONFORM STRICTLY WITH THE REQUIREMENTSOF THE BUILDING CODE OF AUSTRALIA, THE QUEENSLAND BUILDING ACT 1975-1990TOGETHER WITH BUILDING AMENDMENTS ACT 1991, THE QUEENSLANDDEVELOPMENT CODE AND ANY AMENDMENTS & ATTACHMENTS AS PUBLISH.

2-ALL MATERIALS USED FOR CONSTRUCTION WORK COVERED BY THESE PLANS SHALL BENEW AND TOP QUALITY.

3-ALL TIMBER CONSTRUCTIONS SHALL BE IN ACCORDANCE WITH A.S. 1684.2-2010RESIDENTIAL TIMBER FRAMED CONSTRUCTION.

4-ALL DIMENSIONS AND LEVELS MUST BE CHECKED BY BUILDER PRIOR TO COMMENCEOF WORK, ON OR OFF SITE.

5-ALL WET AREAS TO COMPLY WITH A.S. 3740-2004.

6-WC DOORS OPENING INWARDS TO BE FITTED WITH LIFT-OFF HINGES TO ALLOW THEDOOR TO BE REMOVED WHEN IN CLOSED POSITION.

BRICK WORK1-110mm BLOCKWORK ATTACHED TO FRAME WITH APPROVED TIES SPACED HORIZONTALLYAND VERTICALLY TO A.S. 3700. FLASHING / DAMP COURSE TO BE PLACED BELOW FLOOR SLAB LEVELTO PERIMETER OF BUILDING.WEEP HOLES TO BE PLACED EVERY 900mm CENTRE HORIZONTALLY AT DAMP COURSE LEVEL ANDAT OTHER LEVELS WHERE THERE IS HORIZONTAL FLUSHING.

2-ALL BLOCKWORK BRICK TIES & MORTAR IS TO BE TO A.S. 370.

3-ALL WINDOWS & DOORS IN BLOCKWORK TO HAVE FLASHING & BRICK SILLS.

JOINERY1-ALL JOINERY TO BE ALUMINIUM FRAMED WITH POWDECOASTING TO CONFORM TOA.S. 2047 & A.S. 1288.

2-NO LOAD IS TO BEAR ON FRAMES.

3-KEEP ALL FRAMES & GLAZING CLEAR OF CONCRETE, MORTAR & SOLVENTS.

4-ALL SLIDING GLASS DOORS SHALL BE WITHOUT MID-RAILS.

5-ALL HINGED DOORS (INCLUDING FRONT DOOR) TO BE AS NOMINATED ON CONTRACT.

LINING1-INTERNAL LINING TO BE PLASTERBOARD, 10mm TO WALLS & 13mm OR 10mm ABLE TO SPAN 600mmTO CEILINGS.

2-10mm GAP TO BE LEFT BETWEEN FLOOR & SHEETING.

3-FIXING, CONTRACTION JOINT LOCATIONS & LEVEL OF FINISH IS TO BE AS PERA.S./N.Z. 2589-1-1997 OR MANUFACTURE'S. SPECIFICATION.

4-CORNICE TYPES AS PER CONTRACT.

5-WET AREA LINING TO BE VILLABOARD OR SIMILAR APPROVED WATER RESISTANT GRADED LINING.

SOFFIT LININGS1-SOFFITS ARE TO BE BATTENED WITH 38 X 50 LOSP TREATED TIMBER & SHEETED WITH HARDITEX 4.5mmF.C. SHEETING.

ROOF FRAMEWORK1-POST FABRICATED TRUSSES AT NOMINATED PITCH ON PLANS & 600mm CENTRES.

2-ENTIRE ROOF TO BE TRUSS CONSTRUCTIONS UNLESS INDICATED OTHERWISEON FLOOR/FRAMING PLAN.

3-TRUSSES TO BE ENGINEER DESIGNED, FIXED & BRACED AS PER THE MANUFACTURE'S REQUIREMENTS.

4-THE TRUSS MANUFACTURER SHALL PROVIDE ALL NECESSARY DOCUMENTTION & CERTIFICATION ASREQUIRED FOR THE CONSTRUCTION / ERECTION OF THE ROOF FRAMING AND THE APPROVAL BYCOUNCIL / PRIVATED CERTIFIER.

5-WHERE TRUNCATED & GIRDER TRUSSES OCCUR THE TRUSS MANUFACTURER IS TO CHECKTHE ADEQUACY OF LINTELS SUPPORTING THEM AND THE TIE-DOWN REQUIREMENTS.

6-TRUSS MANUFACTURER MUST NOTIFY BUILDER OFANY CHANGE TO LINTEL OR TIE-DOWNDESIGN AT TRUSS DESIGN STAGE.

7-TRUSS MANUFACTURER TO NOMINATE THE NUMBER OF STUDS REQUIRED UNDERTRUNCATED & GIRDER TRUSSES.

8-BOTTOM CHORD BINDERS AS PER TRUSS MANUFATURER'S SPEC. & AT MAXIMUM3000mm CENTRES.

9-PINE TOP PLATES UNDER TRUNCATED & GIRDER TRUSSES TO HAVE THE RIBBON PLATEREPLACED WITH F17 KDH PLATE OF SAME SIZE.KDH PLATE IS TO SPAN MINIMUM OF 3STUDS & CENTRALLY LOCATED UNDER TRUSS.

10-ROOFING MATERIAL TO BE FIXED TO MANUFACTURER'S SPECIFICATIONS FOR TERRAINCATEGORY,PROFILE & FINISH AS PER CONSTRACT.

ROOFING1-NOMINATED ROOFING ON PLANS, TO BE FIXED AS NOMINATED IN ACCORDANE WITH MANUFACTURER'SSPECIFICATION.

QLD SUSTAINABLE HOUSE CODESHOWER ROSESHOWER ROSE TO BE AAA RATING ASSESSED AGAINST AS / NZ 6400-2004 OR A3 STAR RATING UNDER THE WATER EFFICIENCYLABELLING SCHEME (WELS).

TOILET CISTERNSTOILET CISTERNS TO HAVE DUAL FLUSH CAPACITY THAT DOES NOT EXCEED 6 Lts. ON FULL FLUSH &3 Lts. ON HALF FLUSH.

WATER SUPPLYWHERE MAIN WATER POSTSSURE AT THE OUTLED WITHIMTHE BOUNDARY EXCEEDS 500Kpa.A WATER POSTSSURE LIMITINGDEVICE TO BE INSTALLED TO ENSURE POSTSSURE REMAINS BELOW 500Kpa.

PLUMBING NOTES1-ALL DRAINAGE AND PLUMBING WORK MUST BE CARRIED OUT BY A LICENCED PLUMBER / DRAINER ONLY AND STRICTLY INACCORDANCE WITH "THE STANDARD SEWERAGE BY-LAWS".NOT WORK SHALL BE COVERED UO UNTIL IT HAS BEEN EXAMINED & PASSED BY THE COUNCIL'S SPECIFICATION.

2-DISCHARGE ALL WASTERS TO SEWERAGE SYSTEMS IN ACCORDANCE WITH THE LOCAL COUNCIL'S SPECIFIATION.

3-DISCHARGE ROOF WATER DRAINAGE TO STORMWATER CONNECTION POINT AS PER COUNCIL'S REQUIREMENT.

4-ROOFING CONTRACTOR & PLUMBER TO ENSURE THAT THE NUMBER OF DOWNPIPES SHOWN ON PLAN IS ADEQUATE &LOCATED IN THE OPTIMUM POSITIONS.

5-SEWER HOUSE CONNECTION & MAIN LOCATION TO BE CONFIRMED WITH LOCAL AUTHORITY PRIOR TO CONSTRUCTION.UNDERGROUND SERVICE LOCATIONS ARE APPROXIMATE ONLY & SHOULD BE VERIFIED BY LOCAL AUTHORITY PRIORTO CONSTRUCTION.

HOT WATERPROVIDE GAS HOT WATER SYSTEM, APPROVED ELECTRICAL HEAT PUMP SYSTEM OR SOLAR HOT WATER SYSTEM WITH A FIVESTART ENERGY RATING.

SITE NOTES1-DETAIL OF CUT & FILL REQUIREMENTS FOR THIS BUILDING SITE IS BASED ON SURFACELEVELS TAKEN ON THE OWNER/BUILDER SPECIFIED REQUIREMENTS.SUCH DETAIL IS SUBJECT TO VARIATION DEPENDENT UPON GROUND CONDITIONS ENCOUNTERED,SOIL TEST RESULTS & LOCAL AUTHORITY REQUIREMENTS.

2-CLEAR BUILDING AREA OF ALL VEGETATION TO ONE METRE PATH THE BUILDING PEREMITER.REMOVE ALL STUMPS & ROOTS. STOCKPILE TOP SOIL FOR RE-USE ON COMPLETION OFBUILDING CONSTRUCTION. TOP SOIL IS NOT TO BE USED AS FILL MATERIAL.

3-ALL CUT & FILL EMBANKMENTS TO BE NO STEEPER THAN 1:2 AND ALL DRIVEWAY TO BENO STEEPER THAN 1:6.ALL EARTHWORKS TO BE IN ACCORDANCE TO A.S. 2870.

4-SLOPE BUILDING PAD TO DRAIN AWAY FROM RESDENCE AND TO NATURAL GROUND FALL.

5-SITE WORK INDICATED ON THIS PLAN ARE FOR CONSTRUCTION ONLY. IT IS THE CLIENTRESPONSABILITY TO CARRY OUT ALL LANDSCAPING, SITE DRAINAGE, RETAINING WALLSAFTER COMPLETION OF CONSTRUCTION.ALL RETAINING WALLS & EMBANKMENTS SHOWN ARE TO COMPLY WITH THE LOCAL AUTHORITIESPOLICY FOR RETAINING WALLS & EMBANKMENTS ON RESIDENTIAL BUILDING SITES, POSITION OFRETAINING WALLS & EMBANKMENTS MAY VARY ACCORDING TO SITE WORKS.

6-LEVEL OF CONCRETE FLOOR SLAB TO DWELLING IS TO BE VERIFIED BY BUILDER TO ENSURETHAT A MINIMUM HEIGHT ABOVE FINISHED GROUND LEVEL IS ATTAINED IN ACORDANCE TO THEB.C.A. QLD BUILDING ACT-AMMENDMENT ACT 1991 & LOCAL AUTHORITY POLICY AND CONFIRMCUT & FILL LEVELS.

7-BUILDER TO VERIFY THE LOCATION OF ALL SERVICES PRIOR TO CONSTRUCTION.

8-CONFIRM THAT ALL SURVEY PEGS ARE IN THE CORRECT POSITION BEFORE SETTING OUT THEBUILDING, IF ANY DOUBT ARISES CONTACT THEBUILDER/SURVEYOR.

9-AFTER COMPLETION OF CONSTRUCTION OF THE DWELLING, THE OWNER SHALL MAINTAIN THE SITE& DWELLING IN ACCORDANCE WITH THE C.S.I.R.O. LEAFLET SHEET No 10-91 " GUIDE TO HOMEOWNERS ON FOUNDATION MAINTENANCE AND FOOTING PERFORMANCE".

10-DO NOT SCALE DIMENSIONS OFF PLAN.FIGURED DIMENSIONS TO BE USED AT ALL TIMES.

NOTES: DRAWING SYMBOLS USED ON THIS DRAWING MAY NOT BE TRUE REPOSTSENTATIONOF ITEMS TO INCLUDE IN CONTRACT.REFER TO CONTRACT FOR SPECIFIED ITEMS.

@ A3

AWD-00

TITLE PAGE

479- WD 19 DUAL OCCUPANCY - FORPEOPLE WITH DISABILITIES

479- WD 19 DUALOCCUPANCY - FOR PEOPLEWITH DISABILITIES

479- WD 19 DUAL OCCUPANCY -FOR PEOPLE WITH DISABILITIES

02/11/2016

CUSTOM

TURNKEY HOME

WD-00 TITLE PAGE 02/11/2016 AWD-01 ART IMPRESSION 02/11/2016 AWD-03 GROUND FLOOR PLAN 02/11/2016 AWD-04 NAVIGATION & MANOEUVRE PLAN 02/11/2016 AWD-05 ROOF PLAN 02/11/2016 AWD-06 FRONT & LEFT ELEVATIONS 02/11/2016 AWD-07 BACK & RIGHT ELEVATIONS 02/11/2016 AWD-08 CONCRETE SETOUT PLAN 02/11/2016 AWD-09 PENETRATION PLAN 02/11/2016 AWD-10 ELECTRICAL PLAN 02/11/2016 AWD-11 KITCHEN FLOOR PLAN & ELEVATIONS 02/11/2016 AWD-12 KITCHEN FLOOR PLAN & ELEVATIONS 02/11/2016 AWD-13 ENSUITE FLOOR PLAN & ELEVATIONS 02/11/2016 AWD-14 BATHROOM FLOOR PLANS & ELEVATIONS 02/11/2016 AWD-15 L'DRY PLANS & ELEVATIONS 02/11/2016 AWD-16 NAVIGATION PLANS WET AREAS 02/11/2016 AWD-17 MARKETING FLOOR PLAN 02/11/2016 AWD-18 BUILDING DETAILS 02/11/2016 AWD-19 BUILDING DETAILS 02/11/2016 A

A WORKING DRAWING 02/11/2016

Page 2: D:YOARQUITECTURAAA-MECHANICAL DRAFTERAAA …disabilityhousingsolutions.com.au/properties/wp...termite control 1-termite control to be in accordance with a.s. 3660. 1-2000 & bca housing

DRAWING NO: ISSUE:

DRAWING TITLE:

JOB NO:

PROJECT:

PROJECT LOCATION:

CLIENT:

SCALE:

CHECKED BY:

DRAWN BY:

PROJECT DESIGNER:

GENERAL NOTES:THIS DESIGN & DOCUMENTATION REMAIN THEPROPERTY OF MECHANICAL DRAFTERS SERVICES.NO REPRODUCTION & OR ALTERATIONS ARE PERMITTEDWITHOUT THE WRITTEN PERMISSION OFMECHANICAL DRAFTERS SERVICES.

ALL WORKS ARE TO COMPLY WITH THE FOLLOWING:• BUILDING CODE OF AUSTRALIA• THE QUEENSLAND BUILDING ACT• ALL RELEVANT LOCAL AUTHORITIES, BY-LAWS &PLANNING SCHEMES.

© COPYRIGHT-REPRODUCTION IN WHOLE OR PART ISSTRICTLY PROHIBITED WITHOUT PERMISSION

ISSUE AMENDMENT DATE

DATE DRAWN:

DD

DD

DD

DESIGN:

MECHANICAL DRAFTERS SERVICESA.B.N: 51 933 625 430PO Box 1613 Runaway Bay 4216Queensland, AustraliaE: [email protected]: www.mechanicaldrafters.com.au

-THESE PLANS ARE NOT TO BE USED FOR ENGINEER, ARCHITECTURAL OR CONSTRUCTION PURPOSE

@ A3

AWD-01

ART IMPRESSION

479- WD 19 DUAL OCCUPANCY - FORPEOPLE WITH DISABILITIES

479- WD 19 DUALOCCUPANCY - FOR PEOPLEWITH DISABILITIES

479- WD 19 DUAL OCCUPANCY -FOR PEOPLE WITH DISABILITIES

02/11/2016

CUSTOM

TURNKEY HOME

ART IMPRESSION FOR ILLUSTRATIVE PURPOSES ONLY

ART IMPRESSION FOR ILLUSTRATIVE PURPOSES ONLY

A WORKING DRAWING 02/11/2016

Page 3: D:YOARQUITECTURAAA-MECHANICAL DRAFTERAAA …disabilityhousingsolutions.com.au/properties/wp...termite control 1-termite control to be in accordance with a.s. 3660. 1-2000 & bca housing

18 X 09 AW

21 X 30

SGD

D 950

ALFRESCO

FOYER

PORTICO21 X

34 LPD

D94

0

TUB

WM

L'DRYST

21 X 34

LPD

D 940

LINEN

TUB

WM

L'DRY

15 X 18 SW

FOYERPORTICO

18 X 09

AW18 X

09 AW

CSD

920

BEDROOM 1

ROBE

CSD

920

BEDROOM 2 BEDROOM 3

ROBE

D 940

SHR

BATHROOM 2

D 940

SHR

BATHROOM

MEALS

FR

OV/PTY

DW

FR

KITCHEN

DW

15 X 18 SW 18 X 09 AW

21 X 30

SGD

100 X 100 TREATED & PRIMEDTIMBER POST

NOOKNOOK

FAMILY

ALFRESCOENSUITE

18 X 09 AW

15 X 18 SW

D 940

ROBE

NOOK

BEDROOM 1

D 940

ROBE

NOOK

BEDROOM 2

15 X 18 SW

FAMILY

MEALS

SHR

100 X 100 TREATED &PRIMED

TIMBER POST

09 X 06 SW

D 940D 940D 940

D95

0

450 2090 220 19840 220 3400

450 450 220 1420 220 2500 90 1800 90 4140 90 4140 90 6900 220 3400

450 450 220 3250 90 800 90 1800 90 3250 90 800 90 800 90 3250 90 6900 220 3400

220

3000

9013

1090

1200

240

3800

9012

0090

1200

9032

8022

0

100 X 100 TREATED &PRIMEDTIMBER POST

ROBE

220

4400

9012

0090

3800

240

1200

9045

7022

0

220

4400

9050

9024

012

0090

4570

220

220

2900

9014

1090

4485

240

6465

220

2020

220

6955

240

6465

220

6685

240

7175

2020

1612

0

450 450 220 3250 90 800 220 1540 220 3250 90 800 90 800 90 3250 90 6900 220 3400

450 450 4580 1540 15800 3400

26220

450 90 6000 90 2290 90 2750 240 2750 90 3240 240 4280 220 3400

450 90 6000 90 650 90 1550 90 2750 240 2750 90 7760 220 3400

450 90 6000 2290 90 13680 220 3400

450 90 8290 90 1630 90 4140 90 4140 90 3500 220 3400

450 8470 1500 220 800 90 3250 90 3250 90 800 220 3590 3400

450 8470 1500 8810 3590 3400

26220

220

4400

9012

0090

3800

240

1200

9045

7022

0

220

3000

9014

0012

0024

038

0090

2490

9032

8022

0

220

3280

9012

0090

1200

9038

0024

026

0022

010

7020

20

2020

9017

0090

720

9012

0024

038

0090

1200

9045

7022

0

2020

9038

0024

020

1090

1700

9012

0090

3800

9090

0

220

4570

9012

0090

3800

240

3800

9020

20

2020

9038

0024

038

0090

1500

220

436045

8015

0038

9024

059

10

1612

0

1770

1500

3150

3413

3413

3150

3167

3167

D 940

MAINDWELLING

AUXDWELLING

D 1WD-11

MB

MB

D 2WD-12

D 3WD-13

D 4WD-14

D 5WD-15

D 6WD-15

DP

DP

DP

DPDPDP

DP

OV/PTY

OHCOHC

OHC

OHC

OHC

OHC

OHC

KITCHEN

MW

MW

FIREPROOF WALL

DRAWING NO: ISSUE:

DRAWING TITLE:

ISSUE AMENDMENT DATE

DATE DRAWN:

-THESE PLANS ARE NOT TO BE USED FOR ENGINEER, ARCHITECTURAL OR CONSTRUCTION PURPOSE

AWD-03

GROUND FLOOR PLAN

02/11/2016

1 : 100GROUND FLOOR

LIVING AREA - 121.63 m²GARAGE - 24.47 m²ALFRESCO - 24.43 m²PORTICO - 5.14 m²

TOTAL AREA - 175.67 m²

FLOOR AREAS AUX DWELLING

LIVING AREA - 155.02 m²GARAGE - 24.84 m²ALFRESCO - 22.73 m²PORTICO - 3.14 m²

TOTAL AREA - 205.73 m²

FLOOR AREAS MAIN DWELLING

NOTEwindow and door sizes on plans are indicative only. Before orderingany soft furnishings each opening must be site measured asManufactures sizes differ.

A WORKING DRAWING 02/11/2016

Page 4: D:YOARQUITECTURAAA-MECHANICAL DRAFTERAAA …disabilityhousingsolutions.com.au/properties/wp...termite control 1-termite control to be in accordance with a.s. 3660. 1-2000 & bca housing

ALFRESCO

STEP FREE ACCESS

ALFRESCO

SLIP RESISTANT FLOORING

SLIP RESISTANT FLOORING

SLIP RESISTANT FLOORING

PORTICO

PORTICOSLIP RESISTANT FLOORING

STEP FREE ACCESS

SLIP RESISTANT FLOORING

SLIP RESISTANT FLOORING

LOWER

BENCH

FREE MOVEMENT2250mm (Dia)

141018

7010

00

12201200

1000

1870

1310

2020

1750

NAVIG

ATION

1200

NAVIG

A TION

1200

NAVIG

A TION

1200

LOWER

BENCH

2390

2040

1000

122012

00

1200

1610

1000

1220

2040

1220

1000

490 1160 1100

1160

1550

NAVIG

ATION

1200

FREE MOVEMENT2250mm (Dia)

1100 1160 490

1160

1550

1500

2090

CLEA

R ANC

E

900

CLEARANCE

900

CLEA

R ANC

E

920

DRAWING NO: ISSUE:

DRAWING TITLE:

JOB NO:

PROJECT:

PROJECT LOCATION:

CLIENT:

SCALE:

CHECKED BY:

DRAWN BY:

PROJECT DESIGNER:

GENERAL NOTES:THIS DESIGN & DOCUMENTATION REMAIN THEPROPERTY OF MECHANICAL DRAFTERS SERVICES.NO REPRODUCTION & OR ALTERATIONS ARE PERMITTEDWITHOUT THE WRITTEN PERMISSION OFMECHANICAL DRAFTERS SERVICES.

ALL WORKS ARE TO COMPLY WITH THE FOLLOWING:• BUILDING CODE OF AUSTRALIA• THE QUEENSLAND BUILDING ACT• ALL RELEVANT LOCAL AUTHORITIES, BY-LAWS &PLANNING SCHEMES.

© COPYRIGHT-REPRODUCTION IN WHOLE OR PART ISSTRICTLY PROHIBITED WITHOUT PERMISSION

ISSUE AMENDMENT DATE

DATE DRAWN:

DD

DD

DD

DESIGN:

MECHANICAL DRAFTERS SERVICESA.B.N: 51 933 625 430PO Box 1613 Runaway Bay 4216Queensland, AustraliaE: [email protected]: www.mechanicaldrafters.com.au

-THESE PLANS ARE NOT TO BE USED FOR ENGINEER, ARCHITECTURAL OR CONSTRUCTION PURPOSE

As indicated @ A3

AWD-04

NAVIGATION & MANOEUVREPLAN

479- WD 19 DUAL OCCUPANCY - FORPEOPLE WITH DISABILITIES

479- WD 19 DUALOCCUPANCY - FOR PEOPLEWITH DISABILITIES

479- WD 19 DUAL OCCUPANCY -FOR PEOPLE WITH DISABILITIES

02/11/2016

CUSTOM

TURNKEY HOME

A WORKING DRAWING 02/11/2016

1 : 100NAVIGATION & MANOEUVRE PLAN

NOTE--ALL WINDOWS ARE NO HIGHER THAN 600mm ABOVE THE FINISHED FLOOR-WINDOW CONTROLS ARE ABLE TO BE OPERATED WITH ONE HAND AND EASY REACH FROM A SEATED OR STANDING POSITION-LIGHT SWITCHES ARE POSITIONED BETWEEN 900 AND 1100mm ABOVE THE FINISHED FLOOR-POWERPOINTS ARE INTALLED NOT LOWER THAN 300mm ABOVE TE FINISHED FLOOR-DOORWAYS ARE D-PULL STYLE (EASY REACH FROM A SEATED OR STANDING POSITION)-BASINS, SINKS AND TUBS ARE INSTALLED WITH CENTRAL SPOUT

1 : 2001-ACCESS DOOR 1 : 20

02-INTERNAL DOOR

1 : 2003-SLIDING DOOR

Page 5: D:YOARQUITECTURAAA-MECHANICAL DRAFTERAAA …disabilityhousingsolutions.com.au/properties/wp...termite control 1-termite control to be in accordance with a.s. 3660. 1-2000 & bca housing

COLORBOND CUSTOM ORB ROOF SHEET OVERTIMBER TRUSSES @ 22.5° PITCH

DP

DP

DP

DPDPDP

DP

DRAWING NO: ISSUE:

DRAWING TITLE:

JOB NO:

PROJECT:

PROJECT LOCATION:

CLIENT:

SCALE:

CHECKED BY:

DRAWN BY:

PROJECT DESIGNER:

GENERAL NOTES:THIS DESIGN & DOCUMENTATION REMAIN THEPROPERTY OF MECHANICAL DRAFTERS SERVICES.NO REPRODUCTION & OR ALTERATIONS ARE PERMITTEDWITHOUT THE WRITTEN PERMISSION OFMECHANICAL DRAFTERS SERVICES.

ALL WORKS ARE TO COMPLY WITH THE FOLLOWING:• BUILDING CODE OF AUSTRALIA• THE QUEENSLAND BUILDING ACT• ALL RELEVANT LOCAL AUTHORITIES, BY-LAWS &PLANNING SCHEMES.

© COPYRIGHT-REPRODUCTION IN WHOLE OR PART ISSTRICTLY PROHIBITED WITHOUT PERMISSION

ISSUE AMENDMENT DATE

DATE DRAWN:

DD

DD

DD

DESIGN:

MECHANICAL DRAFTERS SERVICESA.B.N: 51 933 625 430PO Box 1613 Runaway Bay 4216Queensland, AustraliaE: [email protected]: www.mechanicaldrafters.com.au

-THESE PLANS ARE NOT TO BE USED FOR ENGINEER, ARCHITECTURAL OR CONSTRUCTION PURPOSE

1 : 100 @ A3

AWD-05

ROOF PLAN

479- WD 19 DUAL OCCUPANCY - FORPEOPLE WITH DISABILITIES

479- WD 19 DUALOCCUPANCY - FOR PEOPLEWITH DISABILITIES

479- WD 19 DUAL OCCUPANCY -FOR PEOPLE WITH DISABILITIES

02/11/2016

CUSTOM

TURNKEY HOME

A WORKING DRAWING 02/11/2016

1 : 100ROOF PLAN

Page 6: D:YOARQUITECTURAAA-MECHANICAL DRAFTERAAA …disabilityhousingsolutions.com.au/properties/wp...termite control 1-termite control to be in accordance with a.s. 3660. 1-2000 & bca housing

2700

P/COATED ALUMI. FRAMED WINDOWS & DOORS

BRICK FACE AS PER SCHEDULE

RAINWATER DISCHARGE TOLEGAL POINT OF CONNECTION

RAINWATER DISCHARGE TOLEGAL POINT OF CONNECTION

COLORBOND CUSTOM ORB ROOF SHEET OVER TIMBER TRUSSES @ 22.5° PITCH

WEATHERBOARD CLADDING

EAVES

450

EAVES

450

100 X 100 TREATED & PRIMED TIMBER POSTFIREPROOF WALL

2700

P/COATED ALUMI. FRAMED WINDOWS & DOORSBRICK FACE AS PER SCHEDULE

RAINWATER DISCHARGE TOLEGAL POINT OF CONNECTION

RAINWATER DISCHARGE TOLEGAL POINT OF CONNECTION

COLORBOND CUSTOM ORB ROOF SHEET OVER TIMBER TRUSSES @ 22.5° PITCH

WEATHERBOARD CLADDING100 X 100 TREATED & PRIMED TIMBER POST

FIREPROOF WALL

100 X 100 TREATED & PRIMED TIMBER POST

EAVES

450

EAVES

450

MB

DRAWING NO: ISSUE:

DRAWING TITLE:

JOB NO:

PROJECT:

PROJECT LOCATION:

CLIENT:

SCALE:

CHECKED BY:

DRAWN BY:

PROJECT DESIGNER:

GENERAL NOTES:THIS DESIGN & DOCUMENTATION REMAIN THEPROPERTY OF MECHANICAL DRAFTERS SERVICES.NO REPRODUCTION & OR ALTERATIONS ARE PERMITTEDWITHOUT THE WRITTEN PERMISSION OFMECHANICAL DRAFTERS SERVICES.

ALL WORKS ARE TO COMPLY WITH THE FOLLOWING:• BUILDING CODE OF AUSTRALIA• THE QUEENSLAND BUILDING ACT• ALL RELEVANT LOCAL AUTHORITIES, BY-LAWS &PLANNING SCHEMES.

© COPYRIGHT-REPRODUCTION IN WHOLE OR PART ISSTRICTLY PROHIBITED WITHOUT PERMISSION

ISSUE AMENDMENT DATE

DATE DRAWN:

DD

DD

DD

DESIGN:

MECHANICAL DRAFTERS SERVICESA.B.N: 51 933 625 430PO Box 1613 Runaway Bay 4216Queensland, AustraliaE: [email protected]: www.mechanicaldrafters.com.au

-THESE PLANS ARE NOT TO BE USED FOR ENGINEER, ARCHITECTURAL OR CONSTRUCTION PURPOSE

1 : 100 @ A3

AWD-06

FRONT & LEFT ELEVATIONS

479- WD 19 DUAL OCCUPANCY - FORPEOPLE WITH DISABILITIES

479- WD 19 DUALOCCUPANCY - FOR PEOPLEWITH DISABILITIES

479- WD 19 DUAL OCCUPANCY -FOR PEOPLE WITH DISABILITIES

02/11/2016

CUSTOM

TURNKEY HOME 1 : 100FRONT ELEVATION

1 : 100LEFT ELEVATION

A WORKING DRAWING 02/11/2016

Page 7: D:YOARQUITECTURAAA-MECHANICAL DRAFTERAAA …disabilityhousingsolutions.com.au/properties/wp...termite control 1-termite control to be in accordance with a.s. 3660. 1-2000 & bca housing

2700

P/COATED ALUMI. FRAMED WINDOWS & DOORS

BRICK FACE AS PER SCHEDULE

RAINWATER DISCHARGE TOLEGAL POINT OF CONNECTION

RAINWATER DISCHARGE TOLEGAL POINT OF CONNECTION

COLORBOND CUSTOM ORB ROOF SHEET OVER TIMBER TRUSSES @ 22.5° PITCH

100 X 100 TREATED & PRIMED TIMBER POSTFIREPROOF WALL

EAVES

450

EAVES

450

2700

P/COATED ALUMI. FRAMED WINDOWS & DOORSBRICK FACE AS PER SCHEDULE

RAINWATER DISCHARGE TOLEGAL POINT OF CONNECTION

RAINWATER DISCHARGE TOLEGAL POINT OF CONNECTION

COLORBOND CUSTOM ORB ROOF SHEET OVER TIMBER TRUSSES @ 22.5° PITCH

WEATHERBOARD CLADDING 100 X 100 TREATED & PRIMED TIMBER POST

FIREPROOF WALL

EAVES

450EAVES

450

MB

DRAWING NO: ISSUE:

DRAWING TITLE:

JOB NO:

PROJECT:

PROJECT LOCATION:

CLIENT:

SCALE:

CHECKED BY:

DRAWN BY:

PROJECT DESIGNER:

GENERAL NOTES:THIS DESIGN & DOCUMENTATION REMAIN THEPROPERTY OF MECHANICAL DRAFTERS SERVICES.NO REPRODUCTION & OR ALTERATIONS ARE PERMITTEDWITHOUT THE WRITTEN PERMISSION OFMECHANICAL DRAFTERS SERVICES.

ALL WORKS ARE TO COMPLY WITH THE FOLLOWING:• BUILDING CODE OF AUSTRALIA• THE QUEENSLAND BUILDING ACT• ALL RELEVANT LOCAL AUTHORITIES, BY-LAWS &PLANNING SCHEMES.

© COPYRIGHT-REPRODUCTION IN WHOLE OR PART ISSTRICTLY PROHIBITED WITHOUT PERMISSION

ISSUE AMENDMENT DATE

DATE DRAWN:

DD

DD

DD

DESIGN:

MECHANICAL DRAFTERS SERVICESA.B.N: 51 933 625 430PO Box 1613 Runaway Bay 4216Queensland, AustraliaE: [email protected]: www.mechanicaldrafters.com.au

-THESE PLANS ARE NOT TO BE USED FOR ENGINEER, ARCHITECTURAL OR CONSTRUCTION PURPOSE

1 : 100 @ A3

AWD-07

BACK & RIGHT ELEVATIONS

479- WD 19 DUAL OCCUPANCY - FORPEOPLE WITH DISABILITIES

479- WD 19 DUALOCCUPANCY - FOR PEOPLEWITH DISABILITIES

479- WD 19 DUAL OCCUPANCY -FOR PEOPLE WITH DISABILITIES

02/11/2016

CUSTOM

TURNKEY HOME 1 : 100BACK ELEVATION

1 : 100RIGHT ELEVATION

A WORKING DRAWING 02/11/2016

Page 8: D:YOARQUITECTURAAA-MECHANICAL DRAFTERAAA …disabilityhousingsolutions.com.au/properties/wp...termite control 1-termite control to be in accordance with a.s. 3660. 1-2000 & bca housing

PORTICO

MAIN CONCRETE SLABALFRESCO

ALFRESCO

PORTICO

EADGE FRAM/SLAB

EADGE FRAM/SLAB

EADGE

FRAM/S

LAB

EADGE FRAM/SLAB

FIREPROOF WALL

8470 1500 150 8510 150 3440 150 3400

8470 1500 8810 3590 3400

25770

450150 4280 150 1540 150 15500 150 3400

450 4580 1540 15800 3400

25770

7175

-FIRE

PROO

F WAL

L24

066

85 -F

IREPR

OOF W

ALL

3400

150

1380

015

018

7015

0

1410

020

20

1612

0

150

2940

150

3090

150

1070

2020

1750

250 1500

150

4280

150

1500

8020

1870

150

4580

1500

8020

2020

1612

0

450150 1490 150

1500

150

2090

750

150

3800

9090

0

4450 1800

26063

26443

6090 229090

3800

6180 740 1550 90 2750 240 2750 8070

2290 90 2750 240 2750 8070

6000

3800

6170

3800

1700

2100

DRAWING NO: ISSUE:

DRAWING TITLE:

JOB NO:

PROJECT:

PROJECT LOCATION:

CLIENT:

SCALE:

CHECKED BY:

DRAWN BY:

PROJECT DESIGNER:

GENERAL NOTES:THIS DESIGN & DOCUMENTATION REMAIN THEPROPERTY OF MECHANICAL DRAFTERS SERVICES.NO REPRODUCTION & OR ALTERATIONS ARE PERMITTEDWITHOUT THE WRITTEN PERMISSION OFMECHANICAL DRAFTERS SERVICES.

ALL WORKS ARE TO COMPLY WITH THE FOLLOWING:• BUILDING CODE OF AUSTRALIA• THE QUEENSLAND BUILDING ACT• ALL RELEVANT LOCAL AUTHORITIES, BY-LAWS &PLANNING SCHEMES.

© COPYRIGHT-REPRODUCTION IN WHOLE OR PART ISSTRICTLY PROHIBITED WITHOUT PERMISSION

ISSUE AMENDMENT DATE

DATE DRAWN:

DD

DD

DD

DESIGN:

MECHANICAL DRAFTERS SERVICESA.B.N: 51 933 625 430PO Box 1613 Runaway Bay 4216Queensland, AustraliaE: [email protected]: www.mechanicaldrafters.com.au

-THESE PLANS ARE NOT TO BE USED FOR ENGINEER, ARCHITECTURAL OR CONSTRUCTION PURPOSE

1 : 100 @ A3

AWD-08

CONCRETE SETOUT PLAN

479- WD 19 DUAL OCCUPANCY - FORPEOPLE WITH DISABILITIES

479- WD 19 DUALOCCUPANCY - FOR PEOPLEWITH DISABILITIES

479- WD 19 DUAL OCCUPANCY -FOR PEOPLE WITH DISABILITIES

02/11/2016

CUSTOM

TURNKEY HOME

A WORKING DRAWING 02/11/2016

1 : 100CONCRETE SETOUT PLAN

Page 9: D:YOARQUITECTURAAA-MECHANICAL DRAFTERAAA …disabilityhousingsolutions.com.au/properties/wp...termite control 1-termite control to be in accordance with a.s. 3660. 1-2000 & bca housing

PORTICO

MAIN CONCRETE SLABALFRESCO

ALFRESCO

PORTICO

FIREPROOF WALL

SKWASTE

SKWASTE

SEWERWASTE

VBWASTE

SEWERWASTE

VBWASTE

TUBWASTE

FLOORWASTE

VBWASTE

SEWERWASTE

SHRWASTE

FLOORWASTE

FLOORWASTE

TUBWASTE

6530

4400 2230 6690

3075

6250

3025

3585

85606560 575

2515

7240 800

1365

7175

-FIRE

PROO

F WAL

L24

066

85 -F

IREPR

OOF W

ALL

545

5830610

1630

420

5305 735

4900 900

7533

8757

GRATE DRAIN

GRATE DRAIN

DRAWING NO: ISSUE:

DRAWING TITLE:

JOB NO:

PROJECT:

PROJECT LOCATION:

CLIENT:

SCALE:

CHECKED BY:

DRAWN BY:

PROJECT DESIGNER:

GENERAL NOTES:THIS DESIGN & DOCUMENTATION REMAIN THEPROPERTY OF MECHANICAL DRAFTERS SERVICES.NO REPRODUCTION & OR ALTERATIONS ARE PERMITTEDWITHOUT THE WRITTEN PERMISSION OFMECHANICAL DRAFTERS SERVICES.

ALL WORKS ARE TO COMPLY WITH THE FOLLOWING:• BUILDING CODE OF AUSTRALIA• THE QUEENSLAND BUILDING ACT• ALL RELEVANT LOCAL AUTHORITIES, BY-LAWS &PLANNING SCHEMES.

© COPYRIGHT-REPRODUCTION IN WHOLE OR PART ISSTRICTLY PROHIBITED WITHOUT PERMISSION

ISSUE AMENDMENT DATE

DATE DRAWN:

DD

DD

DD

DESIGN:

MECHANICAL DRAFTERS SERVICESA.B.N: 51 933 625 430PO Box 1613 Runaway Bay 4216Queensland, AustraliaE: [email protected]: www.mechanicaldrafters.com.au

-THESE PLANS ARE NOT TO BE USED FOR ENGINEER, ARCHITECTURAL OR CONSTRUCTION PURPOSE

1 : 100 @ A3

AWD-09

PENETRATION PLAN

479- WD 19 DUAL OCCUPANCY - FORPEOPLE WITH DISABILITIES

479- WD 19 DUALOCCUPANCY - FOR PEOPLEWITH DISABILITIES

479- WD 19 DUAL OCCUPANCY -FOR PEOPLE WITH DISABILITIES

02/11/2016

CUSTOM

TURNKEY HOME

A WORKING DRAWING 02/11/2016

1 : 100PENETRATION PLAN

Page 10: D:YOARQUITECTURAAA-MECHANICAL DRAFTERAAA …disabilityhousingsolutions.com.au/properties/wp...termite control 1-termite control to be in accordance with a.s. 3660. 1-2000 & bca housing

WPWP

MB

TWO WAY

TWO WAY

TWO SWITCHES

MB

DRAWING NO: ISSUE:

DRAWING TITLE:

JOB NO:

PROJECT:

PROJECT LOCATION:

CLIENT:

SCALE:

CHECKED BY:

DRAWN BY:

PROJECT DESIGNER:

GENERAL NOTES:THIS DESIGN & DOCUMENTATION REMAIN THEPROPERTY OF MECHANICAL DRAFTERS SERVICES.NO REPRODUCTION & OR ALTERATIONS ARE PERMITTEDWITHOUT THE WRITTEN PERMISSION OFMECHANICAL DRAFTERS SERVICES.

ALL WORKS ARE TO COMPLY WITH THE FOLLOWING:• BUILDING CODE OF AUSTRALIA• THE QUEENSLAND BUILDING ACT• ALL RELEVANT LOCAL AUTHORITIES, BY-LAWS &PLANNING SCHEMES.

© COPYRIGHT-REPRODUCTION IN WHOLE OR PART ISSTRICTLY PROHIBITED WITHOUT PERMISSION

ISSUE AMENDMENT DATE

DATE DRAWN:

DD

DD

DD

DESIGN:

MECHANICAL DRAFTERS SERVICESA.B.N: 51 933 625 430PO Box 1613 Runaway Bay 4216Queensland, AustraliaE: [email protected]: www.mechanicaldrafters.com.au

-THESE PLANS ARE NOT TO BE USED FOR ENGINEER, ARCHITECTURAL OR CONSTRUCTION PURPOSE

1 : 100 @ A3

AWD-10

ELECTRICAL PLAN

479- WD 19 DUAL OCCUPANCY - FORPEOPLE WITH DISABILITIES

479- WD 19 DUALOCCUPANCY - FOR PEOPLEWITH DISABILITIES

479- WD 19 DUAL OCCUPANCY -FOR PEOPLE WITH DISABILITIES

02/11/2016

CUSTOM

TURNKEY HOME

1 : 100ELECTRICAL PLAN

A WORKING DRAWING 02/11/2016ELECTRICAL LEGEND

DOUBLE GPO WATER PROOF

DOUBLE GPO

SINGLE GPO

WALL MOUNTED BUNKER LIGHT

WALL MOUNTED UP / DOWN LIGHT

DOUBLE WALL MOUNTED FLOOD LIGHT

BATTEN LIGHT

EXTERNAL BATTEN LIGHT

CHANDELIER - DROP LIGHTS

DOUBLE TUBE-FLURO LIGHT

HARD WIRED SMOKE ALARM

TELEVISION POINT

TELEPHONE POINT

RJ6 CAT 6 DATA POINT

IXL TASTICS LIGHT/EXHAUST/HEAT

CEILING FAN

FIBRE OPTIC AVAILABLE

MECHANICAL VENTILATION

CEILING FAN WITH OYSTER LIGHT

LEED DOWN LIGHT

E

1

WP

Page 11: D:YOARQUITECTURAAA-MECHANICAL DRAFTERAAA …disabilityhousingsolutions.com.au/properties/wp...termite control 1-termite control to be in accordance with a.s. 3660. 1-2000 & bca housing

WD-11A

B

FR

PTY

DW

OHC

OHC

OHC

KITCHENSLIP RESISTANT FLOORING

MW

9060

0 -OV

1000

-FR

2065

0 -DW

470

600 -

CT63

060

0 -BE

NCH

220

220

1830

-LOW

ER11

2020

1000

-FR

600 -

PTY

909016

2029

5022

0

220

4570

90

90 600 -PTY

300 -OHC

300 -OHC

90 600 -BENCH 1330 640 -MW

90 1930 -LOWER 640 -MW

90 2570

300 -

OHC

220

600 -

BENC

H

SK

ELECT.CT.

RANGEHOODOVER

OVFR

DW

123

4

BULKHEAD

ELECT.CT.

20mmBENCH

RANGEHOODFLUSHS TO EAVES

SPLASHBACK

220 1830 -LOWER BENCH 20450 -DRS 650 -DW 20 1000 -FR 600 -PTY/OV 90

220 600 -BENCH 1230 1120 1620 90

220 2950 1620 90

220 4570 90

700 -

OPEN

500 500300 310 310 310 600 380 370 370

600

300 -

OHC

1800

-FR

600

2100

-PTY

720

592 -

OV78

860

0

900

410

790 -

OHC

600

720

590

790

600

720 -

LOWE

R BEN

CH41

097

0 -OH

C60

0

2700

1

MV

BULKHEAD

SPLASHBACK20mmBENCHSK

90600 -BENCH1330 -LOWER BENCH640 -MW

2570 90

900

410

790 -

OHC

600

2700

900

410

790 -

OHC

600

720 -

LOWE

R BEN

CH41

097

0 -OH

C60

0

300326326326326326320320

DRAWING NO: ISSUE:

DRAWING TITLE:

JOB NO:

PROJECT:

PROJECT LOCATION:

CLIENT:

SCALE:

CHECKED BY:

DRAWN BY:

PROJECT DESIGNER:

GENERAL NOTES:THIS DESIGN & DOCUMENTATION REMAIN THEPROPERTY OF MECHANICAL DRAFTERS SERVICES.NO REPRODUCTION & OR ALTERATIONS ARE PERMITTEDWITHOUT THE WRITTEN PERMISSION OFMECHANICAL DRAFTERS SERVICES.

ALL WORKS ARE TO COMPLY WITH THE FOLLOWING:• BUILDING CODE OF AUSTRALIA• THE QUEENSLAND BUILDING ACT• ALL RELEVANT LOCAL AUTHORITIES, BY-LAWS &PLANNING SCHEMES.

© COPYRIGHT-REPRODUCTION IN WHOLE OR PART ISSTRICTLY PROHIBITED WITHOUT PERMISSION

ISSUE AMENDMENT DATE

DATE DRAWN:

DD

DD

DD

DESIGN:

MECHANICAL DRAFTERS SERVICESA.B.N: 51 933 625 430PO Box 1613 Runaway Bay 4216Queensland, AustraliaE: [email protected]: www.mechanicaldrafters.com.au

-THESE PLANS ARE NOT TO BE USED FOR ENGINEER, ARCHITECTURAL OR CONSTRUCTION PURPOSE

1 : 50 @ A3

AWD-11

KITCHEN FLOOR PLAN &ELEVATIONS

479- WD 19 DUAL OCCUPANCY - FORPEOPLE WITH DISABILITIES

479- WD 19 DUALOCCUPANCY - FOR PEOPLEWITH DISABILITIES

479- WD 19 DUAL OCCUPANCY -FOR PEOPLE WITH DISABILITIES

02/11/2016

CUSTOM

TURNKEY HOME

A WORKING DRAWING 02/11/2016

1 : 50D1

1 : 50A

1 : 50B

Page 12: D:YOARQUITECTURAAA-MECHANICAL DRAFTERAAA …disabilityhousingsolutions.com.au/properties/wp...termite control 1-termite control to be in accordance with a.s. 3660. 1-2000 & bca housing

WD-12C

D

E

FR

KITCHEN

DW

OV/PTY

OHC

OHC

OHC

OHC

MW

SLIP RESISTANT FLOORING

90 600 1350 690 -DW

90 600 2040

90 2640

300

600 -

LOWE

R54

460

0 -CT

361

1485

240

240

600 -

FR88

521

05 -L

OWER

300

900

2390

600 -

BENC

H24

0

3890

240

90 600 -BENCH 1020 20 1000 -FR 600 -OV 240

90 1620 20 1000 -FR 600 -PTY 240

90 1620 1860

90 3240 24024

060

0 -PT

Y/OV

2390

900 -

BENC

H

300 -

OHC

300 -OHC

90 1950 -LOWER 690 -DW

ELECT.CT.

RANGEHOODOVER

240 600 -BENCH 415 450 -DRS20 1505 600 300

240 600 -MW 885 1505 900 -BENCH

240 1485 2105 -LOWER BENCH 300

240 3890

20mmBENCH

SK

BULKHEAD

SPLASHBACK

1

234

MWELECT.CT.

RANGEHOOD FLUSHSTO EAVES

900 -

BENC

H12

0060

0

600

970 -

OHC

410

720 -

LOWE

R BEN

CH

900

410

790 -

OHC

600

2700

700 -

OPEN

300 296 296 593 361 600 361 361 361 361

2405

20mmBENCH

SK

DW

ELECT.CT.

EQEQ

20650 -DW20135060090

6901950 -LOWER BENCH90

1800

900

1980

720

600

970 -

OHC

410

720

2700

300 -OHC

90600420600 -MW201000 -FR600 -PTY/OV

9060010201620

903240

720 -

LOWE

R BEN

CH41

097

0 -OH

C60

0

720

592 -

OV78

860

0

2100

600

1800

300

600

900

410

790 -

OHC

600

2700

500500300300 300264264264264264

20mmBENCH

OV FR

MW

1

SPLASHBACK

BULKHEAD

DRAWING NO: ISSUE:

DRAWING TITLE:

JOB NO:

PROJECT:

PROJECT LOCATION:

CLIENT:

SCALE:

CHECKED BY:

DRAWN BY:

PROJECT DESIGNER:

GENERAL NOTES:THIS DESIGN & DOCUMENTATION REMAIN THEPROPERTY OF MECHANICAL DRAFTERS SERVICES.NO REPRODUCTION & OR ALTERATIONS ARE PERMITTEDWITHOUT THE WRITTEN PERMISSION OFMECHANICAL DRAFTERS SERVICES.

ALL WORKS ARE TO COMPLY WITH THE FOLLOWING:• BUILDING CODE OF AUSTRALIA• THE QUEENSLAND BUILDING ACT• ALL RELEVANT LOCAL AUTHORITIES, BY-LAWS &PLANNING SCHEMES.

© COPYRIGHT-REPRODUCTION IN WHOLE OR PART ISSTRICTLY PROHIBITED WITHOUT PERMISSION

ISSUE AMENDMENT DATE

DATE DRAWN:

DD

DD

DD

DESIGN:

MECHANICAL DRAFTERS SERVICESA.B.N: 51 933 625 430PO Box 1613 Runaway Bay 4216Queensland, AustraliaE: [email protected]: www.mechanicaldrafters.com.au

-THESE PLANS ARE NOT TO BE USED FOR ENGINEER, ARCHITECTURAL OR CONSTRUCTION PURPOSE

1 : 50 @ A3

AWD-12

KITCHEN FLOOR PLAN &ELEVATIONS

479- WD 19 DUAL OCCUPANCY - FORPEOPLE WITH DISABILITIES

479- WD 19 DUALOCCUPANCY - FOR PEOPLEWITH DISABILITIES

479- WD 19 DUAL OCCUPANCY -FOR PEOPLE WITH DISABILITIES

02/11/2016

CUSTOM

TURNKEY HOME

A WORKING DRAWING 02/11/2016

1 : 50D2

1 : 50C

1 : 50D

1 : 50E

Page 13: D:YOARQUITECTURAAA-MECHANICAL DRAFTERAAA …disabilityhousingsolutions.com.au/properties/wp...termite control 1-termite control to be in accordance with a.s. 3660. 1-2000 & bca housing

WD-13 F

G

ENSUITE

SHR

TILE

VB

WC

TRH

TR

TR

CSD

920

CSD

920

700

9012

0090

0 -VB

1700

90

9038

0090

90 900 -SHR 900 -WC 90

450 450450 450

90 1800 90

9090

0 -SH

R29

009090

3800

90

TRHVB

MIRROR

90 1200 900 -VB 1700 90

90 3800 90

200 -

TILE

600 -

TRH

800 -

TR

2000

-VB

2700

TR

TILE

WC

TRH

TILE

SHRTILE

MIXER

EQ EQ

90 900 -WC 900 -SHR 90

90180090

450450

200 -

TILE

600 -

TRH

2100

-SHR

TILE 27

00

DRAWING NO: ISSUE:

DRAWING TITLE:

JOB NO:

PROJECT:

PROJECT LOCATION:

CLIENT:

SCALE:

CHECKED BY:

DRAWN BY:

PROJECT DESIGNER:

GENERAL NOTES:THIS DESIGN & DOCUMENTATION REMAIN THEPROPERTY OF MECHANICAL DRAFTERS SERVICES.NO REPRODUCTION & OR ALTERATIONS ARE PERMITTEDWITHOUT THE WRITTEN PERMISSION OFMECHANICAL DRAFTERS SERVICES.

ALL WORKS ARE TO COMPLY WITH THE FOLLOWING:• BUILDING CODE OF AUSTRALIA• THE QUEENSLAND BUILDING ACT• ALL RELEVANT LOCAL AUTHORITIES, BY-LAWS &PLANNING SCHEMES.

© COPYRIGHT-REPRODUCTION IN WHOLE OR PART ISSTRICTLY PROHIBITED WITHOUT PERMISSION

ISSUE AMENDMENT DATE

DATE DRAWN:

DD

DD

DD

DESIGN:

MECHANICAL DRAFTERS SERVICESA.B.N: 51 933 625 430PO Box 1613 Runaway Bay 4216Queensland, AustraliaE: [email protected]: www.mechanicaldrafters.com.au

-THESE PLANS ARE NOT TO BE USED FOR ENGINEER, ARCHITECTURAL OR CONSTRUCTION PURPOSE

1 : 50 @ A3

AWD-13

ENSUITE FLOOR PLAN &ELEVATIONS

479- WD 19 DUAL OCCUPANCY - FORPEOPLE WITH DISABILITIES

479- WD 19 DUALOCCUPANCY - FOR PEOPLEWITH DISABILITIES

479- WD 19 DUAL OCCUPANCY -FOR PEOPLE WITH DISABILITIES

02/11/2016

CUSTOM

TURNKEY HOME

A WORKING DRAWING 02/11/2016

1 : 50D3

1 : 50F

1 : 50G

Page 14: D:YOARQUITECTURAAA-MECHANICAL DRAFTERAAA …disabilityhousingsolutions.com.au/properties/wp...termite control 1-termite control to be in accordance with a.s. 3660. 1-2000 & bca housing

WD-14

H

I

SHR

BATHROOM 2

90 1650 -WC 1100 -SHR 240

490 550 550

90 2750 240

240

1160

-SHR

2640

90

240

3800

90

90 1370 -VB 1380 240

90 2750 240

240

3800

90

TRH

WC

TR

TRVB

GRATE DRAIN

TILE

MIXER

D 940

NOGGING900mm

NOGGING1160 mm

NOGGING1700 mm

720

1280

MIRR

OR

2000

-VB

OPEN

ING

700

VB

12

3TILE

TR

TR

600 -

TR

200 -

TILE90

0 -TR

90 830 450

901370 -VB1380240

902750240

470 -

WC

200 -

TILE

600 -

TRH40

0 -NO

GGING

600 90

0 -TR

900 -

NOGG

ING60

0

2100

-SHR

TILE 27

00

TR

MIXER

SHRTILE

WCTILE

TRH

NOGGING900 X 1100mm

NOGGING400 X 900mm

FLUSHING CONTROL

355 -WC EQ EQ

SHR RAIL

2401100 -SHR1160490

2401100 -SHR1650 -WC90

DRAWING NO: ISSUE:

DRAWING TITLE:

JOB NO:

PROJECT:

PROJECT LOCATION:

CLIENT:

SCALE:

CHECKED BY:

DRAWN BY:

PROJECT DESIGNER:

GENERAL NOTES:THIS DESIGN & DOCUMENTATION REMAIN THEPROPERTY OF MECHANICAL DRAFTERS SERVICES.NO REPRODUCTION & OR ALTERATIONS ARE PERMITTEDWITHOUT THE WRITTEN PERMISSION OFMECHANICAL DRAFTERS SERVICES.

ALL WORKS ARE TO COMPLY WITH THE FOLLOWING:• BUILDING CODE OF AUSTRALIA• THE QUEENSLAND BUILDING ACT• ALL RELEVANT LOCAL AUTHORITIES, BY-LAWS &PLANNING SCHEMES.

© COPYRIGHT-REPRODUCTION IN WHOLE OR PART ISSTRICTLY PROHIBITED WITHOUT PERMISSION

ISSUE AMENDMENT DATE

DATE DRAWN:

DD

DD

DD

DESIGN:

MECHANICAL DRAFTERS SERVICESA.B.N: 51 933 625 430PO Box 1613 Runaway Bay 4216Queensland, AustraliaE: [email protected]: www.mechanicaldrafters.com.au

-THESE PLANS ARE NOT TO BE USED FOR ENGINEER, ARCHITECTURAL OR CONSTRUCTION PURPOSE

1 : 50 @ A3

AWD-14

BATHROOM FLOOR PLANS &ELEVATIONS

479- WD 19 DUAL OCCUPANCY - FORPEOPLE WITH DISABILITIES

479- WD 19 DUALOCCUPANCY - FOR PEOPLEWITH DISABILITIES

479- WD 19 DUAL OCCUPANCY -FOR PEOPLE WITH DISABILITIES

02/11/2016

CUSTOM

TURNKEY HOME

A WORKING DRAWING 02/11/2016

1 : 50D4 1 : 50

H

1 : 50I

Page 15: D:YOARQUITECTURAAA-MECHANICAL DRAFTERAAA …disabilityhousingsolutions.com.au/properties/wp...termite control 1-termite control to be in accordance with a.s. 3660. 1-2000 & bca housing

WD-15 J

TUB

WML'DRY

ST

TILE

9085

0 -WM

850 -

TUB

9072

0 -ST

9012

0024

0

9017

00 -L

'DRY

9072

0 -ST

9012

0024

0

9038

0024

0

1550 740 90

D94

0

WD-15K

LINEN

TUB

WM

L'DRY

9085

0 -WM

850 -

TUB

9020

10 -L

N24

0

9017

00 -L

'DRY

9020

10 -L

N24

0

9038

0024

0

90 650 -LN 90 1550 90

90 740 1550 90

TILE

D 940

90 850 -WM 850 90 720 -ST 90 1200 240

EQ EQ

90 1700 -L'DRY 90 720 -ST 90 1200 240

90 3800 240

600 -

TILE

900

2700

TUBTILE

WMST

90 850 -WM 850 2100 -LN 240

EQ EQ

90 1700 -L'DRY 2100 -LN 240

90 3800 240

TILE

WM

LN

TUB

600 -

TILE

900

2700

DRAWING NO: ISSUE:

DRAWING TITLE:

JOB NO:

PROJECT:

PROJECT LOCATION:

CLIENT:

SCALE:

CHECKED BY:

DRAWN BY:

PROJECT DESIGNER:

GENERAL NOTES:THIS DESIGN & DOCUMENTATION REMAIN THEPROPERTY OF MECHANICAL DRAFTERS SERVICES.NO REPRODUCTION & OR ALTERATIONS ARE PERMITTEDWITHOUT THE WRITTEN PERMISSION OFMECHANICAL DRAFTERS SERVICES.

ALL WORKS ARE TO COMPLY WITH THE FOLLOWING:• BUILDING CODE OF AUSTRALIA• THE QUEENSLAND BUILDING ACT• ALL RELEVANT LOCAL AUTHORITIES, BY-LAWS &PLANNING SCHEMES.

© COPYRIGHT-REPRODUCTION IN WHOLE OR PART ISSTRICTLY PROHIBITED WITHOUT PERMISSION

ISSUE AMENDMENT DATE

DATE DRAWN:

DD

DD

DD

DESIGN:

MECHANICAL DRAFTERS SERVICESA.B.N: 51 933 625 430PO Box 1613 Runaway Bay 4216Queensland, AustraliaE: [email protected]: www.mechanicaldrafters.com.au

-THESE PLANS ARE NOT TO BE USED FOR ENGINEER, ARCHITECTURAL OR CONSTRUCTION PURPOSE

1 : 50 @ A3

AWD-15

L'DRY PLANS & ELEVATIONS

479- WD 19 DUAL OCCUPANCY - FORPEOPLE WITH DISABILITIES

479- WD 19 DUALOCCUPANCY - FOR PEOPLEWITH DISABILITIES

479- WD 19 DUAL OCCUPANCY -FOR PEOPLE WITH DISABILITIES

02/11/2016

CUSTOM

TURNKEY HOME

A WORKING DRAWING 02/11/2016

1 : 50D5

1 : 50D6

1 : 50J

1 : 50K

Page 16: D:YOARQUITECTURAAA-MECHANICAL DRAFTERAAA …disabilityhousingsolutions.com.au/properties/wp...termite control 1-termite control to be in accordance with a.s. 3660. 1-2000 & bca housing

FR

PTY

DW

OHC

OHC

OHC

KITCHEN

CIRCULATION

MWSK

18803970

LOWER

BENCH

FR

KITCHEN

DW

OV/PTY

OHC

OHC

OHC

OHC

MW

CIRCULATION

LOWER

BENCH

2300

2640

SHR

BATHROOM 2

WC

CIRCULATION

D 940

1400

2750

TUB

WM

L'DRY

ST

CIRCULATION

D94

0

2600

1550

LINEN

TUB

WM

L'DRY

CIRUCLATION

D 940

1550

3800

DRAWING NO: ISSUE:

DRAWING TITLE:

JOB NO:

PROJECT:

PROJECT LOCATION:

CLIENT:

SCALE:

CHECKED BY:

DRAWN BY:

PROJECT DESIGNER:

GENERAL NOTES:THIS DESIGN & DOCUMENTATION REMAIN THEPROPERTY OF MECHANICAL DRAFTERS SERVICES.NO REPRODUCTION & OR ALTERATIONS ARE PERMITTEDWITHOUT THE WRITTEN PERMISSION OFMECHANICAL DRAFTERS SERVICES.

ALL WORKS ARE TO COMPLY WITH THE FOLLOWING:• BUILDING CODE OF AUSTRALIA• THE QUEENSLAND BUILDING ACT• ALL RELEVANT LOCAL AUTHORITIES, BY-LAWS &PLANNING SCHEMES.

© COPYRIGHT-REPRODUCTION IN WHOLE OR PART ISSTRICTLY PROHIBITED WITHOUT PERMISSION

ISSUE AMENDMENT DATE

DATE DRAWN:

DD

DD

DD

DESIGN:

MECHANICAL DRAFTERS SERVICESA.B.N: 51 933 625 430PO Box 1613 Runaway Bay 4216Queensland, AustraliaE: [email protected]: www.mechanicaldrafters.com.au

-THESE PLANS ARE NOT TO BE USED FOR ENGINEER, ARCHITECTURAL OR CONSTRUCTION PURPOSE

1 : 50 @ A3

AWD-16

NAVIGATION PLANS WETAREAS

479- WD 19 DUAL OCCUPANCY - FORPEOPLE WITH DISABILITIES

479- WD 19 DUALOCCUPANCY - FOR PEOPLEWITH DISABILITIES

479- WD 19 DUAL OCCUPANCY -FOR PEOPLE WITH DISABILITIES

02/11/2016

CUSTOM

TURNKEY HOME

A WORKING DRAWING 02/11/2016

1 : 50N1 1 : 50

N2

1 : 50N4

1 : 50N5

1 : 50N6

Page 17: D:YOARQUITECTURAAA-MECHANICAL DRAFTERAAA …disabilityhousingsolutions.com.au/properties/wp...termite control 1-termite control to be in accordance with a.s. 3660. 1-2000 & bca housing

ALFRESCO

FOYER

PORTICO

TUB

WM

L'DRYST

LINEN

TUB

WM

L'DRY

FOYERPORTICO

BEDROOM 1

ROBE BEDROOM 2 BEDROOM 3

ROBE

SHR

BATHROOM 2SHR

BATHROOM

MEALS

FR

OV/PTY

DW

FR

KITCHEN

DW

NOOKNOOK

FAMILY

ALFRESCOENSUITE

ROBE

NOOK

BEDROOM 1

ROBE

NOOK

BEDROOM 2

FAMILY

MEALS

SHR ROBE

MAINDWELLING

AUXDWELLING

OV/PTY

OHCOHC

OHC

OHC

OHC

OHC

OHC

KITCHEN

MW

MW

DRAWING NO: ISSUE:

DRAWING TITLE:

JOB NO:

PROJECT:

PROJECT LOCATION:

CLIENT:

SCALE:

CHECKED BY:

DRAWN BY:

PROJECT DESIGNER:

GENERAL NOTES:THIS DESIGN & DOCUMENTATION REMAIN THEPROPERTY OF MECHANICAL DRAFTERS SERVICES.NO REPRODUCTION & OR ALTERATIONS ARE PERMITTEDWITHOUT THE WRITTEN PERMISSION OFMECHANICAL DRAFTERS SERVICES.

ALL WORKS ARE TO COMPLY WITH THE FOLLOWING:• BUILDING CODE OF AUSTRALIA• THE QUEENSLAND BUILDING ACT• ALL RELEVANT LOCAL AUTHORITIES, BY-LAWS &PLANNING SCHEMES.

© COPYRIGHT-REPRODUCTION IN WHOLE OR PART ISSTRICTLY PROHIBITED WITHOUT PERMISSION

ISSUE AMENDMENT DATE

DATE DRAWN:

DD

DD

DD

DESIGN:

MECHANICAL DRAFTERS SERVICESA.B.N: 51 933 625 430PO Box 1613 Runaway Bay 4216Queensland, AustraliaE: [email protected]: www.mechanicaldrafters.com.au

-THESE PLANS ARE NOT TO BE USED FOR ENGINEER, ARCHITECTURAL OR CONSTRUCTION PURPOSE

1 : 100 @ A3

AWD-17

MARKETING FLOOR PLAN

479- WD 19 DUAL OCCUPANCY - FORPEOPLE WITH DISABILITIES

479- WD 19 DUALOCCUPANCY - FOR PEOPLEWITH DISABILITIES

479- WD 19 DUAL OCCUPANCY -FOR PEOPLE WITH DISABILITIES

02/11/2016

CUSTOM

TURNKEY HOME

A WORKING DRAWING 02/11/2016

1 : 100MARKETING GROUND FLOOR

Page 18: D:YOARQUITECTURAAA-MECHANICAL DRAFTERAAA …disabilityhousingsolutions.com.au/properties/wp...termite control 1-termite control to be in accordance with a.s. 3660. 1-2000 & bca housing

COLOURBOND CUSTOM ORB ROOF SHEETING

TIMBER ROOF TRUSSES DESIGNED BY MANUFACTURE

50mm TOP HAT ROOF BATTEN

150 QUAD GUTTER

EMLINE FASCIA

10mm REINFORCED PLASTER BOARD TO CEILING90mm PLASTER CORNICE

LINTEL SIZE AS PER LINTEL PLAN

4mm FC SHEET TO SOFFIT

70 X 35mm TIMBER WALL FRAME

110mm FACE BRICK

10mm PLASTER BOARD TO WALL LINING WITH PAINT FINISH

CONCRETE FOOTING & SLAB DESIGNED BY ENGINEER

APPROVED VAPOR BARRIER

PAD LEVEL

FLOOR LEVEL

CEILING LEVEL

JOINERY LEVEL

DPC BARRIER

ALUMI. FRAMED WINDOW AS PER DESIGN

110mm SILL BRICK

68 X 12mm PRIMED MDF SKIRTING

REFLECTIVE WALL WRAP TO CAVITY

R2.5 CEILING INSULATION

HEEL250

AS PE

R SPE

CS30

0

AS PE

R SPE

CS

75mm

MIN

ROOFING AS PER SCHEDULE

TIMBER ROOF TRUSSES DESIGNED BY MANUFACTURE

150 QUAD GUTTER

EMLINE FASCIA10mm REINFORCED PLASTER BOARD TO CEILING

90mm PLASTER CORNICE

LINTEL SIZE AS PER LINTEL PLAN

CEILING LEVEL

JOINERY LEVEL

R2.5 CEILING INSULATION

PACKING AS REQUIRED

LINE OF HWD POST

DRAWING NO: ISSUE:

DRAWING TITLE:

JOB NO:

PROJECT:

PROJECT LOCATION:

CLIENT:

SCALE:

CHECKED BY:

DRAWN BY:

PROJECT DESIGNER:

GENERAL NOTES:THIS DESIGN & DOCUMENTATION REMAIN THEPROPERTY OF MECHANICAL DRAFTERS SERVICES.NO REPRODUCTION & OR ALTERATIONS ARE PERMITTEDWITHOUT THE WRITTEN PERMISSION OFMECHANICAL DRAFTERS SERVICES.

ALL WORKS ARE TO COMPLY WITH THE FOLLOWING:• BUILDING CODE OF AUSTRALIA• THE QUEENSLAND BUILDING ACT• ALL RELEVANT LOCAL AUTHORITIES, BY-LAWS &PLANNING SCHEMES.

© COPYRIGHT-REPRODUCTION IN WHOLE OR PART ISSTRICTLY PROHIBITED WITHOUT PERMISSION

ISSUE AMENDMENT DATE

DATE DRAWN:

DD

DD

DD

DESIGN:

MECHANICAL DRAFTERS SERVICESA.B.N: 51 933 625 430PO Box 1613 Runaway Bay 4216Queensland, AustraliaE: [email protected]: www.mechanicaldrafters.com.au

-THESE PLANS ARE NOT TO BE USED FOR ENGINEER, ARCHITECTURAL OR CONSTRUCTION PURPOSE

1 : 20 @ A3

AWD-18

BUILDING DETAILS

479- WD 19 DUAL OCCUPANCY - FORPEOPLE WITH DISABILITIES

479- WD 19 DUALOCCUPANCY - FOR PEOPLEWITH DISABILITIES

479- WD 19 DUAL OCCUPANCY -FOR PEOPLE WITH DISABILITIES

02/11/2016

CUSTOM

TURNKEY HOME

1 : 20TYP. BRICK VENEER WALL DETAIL - CB ROOF

1 : 20TYP. ALFRESCO EAVE DETAIL

A WORKING DRAWING 02/11/2016

Page 19: D:YOARQUITECTURAAA-MECHANICAL DRAFTERAAA …disabilityhousingsolutions.com.au/properties/wp...termite control 1-termite control to be in accordance with a.s. 3660. 1-2000 & bca housing

ROOFING AS PER SCHEDULE

TIMBER ROOF TRUSSES DESIGNED BY MANUFACTURE

150 QUAD GUTTER

EMLINE FASCIA10mm REINFORCED PLASTER BOARD TO CEILING

90mm PLASTER CORNICE

LINTEL SIZE AS PER LINTEL PLAN

70 X 35mm TIMBER WALL FRAME

110mm FACE BRICK

10mm PLASTER BOARD TO WALL LINING WITH PAINT FINISH

CEILING LEVEL

JOINERY LEVEL

REFLECTIVE WALL WRAP TO CAVITY

R2.5 CEILING INSULATION

TRIMMER AS REQUIRED

SQUARE SET CORNERS

PACKING AS REQUIRED

EAVES OVERHANG

450

TIMBER ROOF TRUSSES DESIGNED BY MANUFACTURE

150 QUAD GUTTER

FASCIA

SQUARE SET TO ALL CEILINGS USING METAL STRIP

4mm FC SHEET TO SOFFIT

R3.0 CEILING INSULATION

CONCRETE ROOF TILES AS PER SCHEDULE

PFC AS PER ENGINEERS DETAIL

10mm WATER PROOF PLASTERBOARD CEILIING TO SOFFITT

PACKING AS REQUIRED

70 X 35mm TIMBER WALL FRAME

FACE BRICK

CONCRETE FOOTING & SLAB DESIGNED BY ENGINEER

APPROVED VAPOR BARRIER

PAD LEVEL

FLOOR LEVEL

DPC BARRIERPRIMED MDF SKIRTING

REFLECTIVE WALL WRAP TO CAVITY

ACCESS DOOR

75mm MIN. TERMITE INSPECTION ZONE

MINIMUM FALL

INTERNAL FLOOR LEVEL

NON-COMBUSTIBLE ROOFING

NON-COMBUSTIBLE GUTTER & FLASHING(POSITION AND SHAPE INDICATIVE ONLY)

FACE BRICK WALL

CEILING LEVEL

DRAWING NO: ISSUE:

DRAWING TITLE:

JOB NO:

PROJECT:

PROJECT LOCATION:

CLIENT:

SCALE:

CHECKED BY:

DRAWN BY:

PROJECT DESIGNER:

GENERAL NOTES:THIS DESIGN & DOCUMENTATION REMAIN THEPROPERTY OF MECHANICAL DRAFTERS SERVICES.NO REPRODUCTION & OR ALTERATIONS ARE PERMITTEDWITHOUT THE WRITTEN PERMISSION OFMECHANICAL DRAFTERS SERVICES.

ALL WORKS ARE TO COMPLY WITH THE FOLLOWING:• BUILDING CODE OF AUSTRALIA• THE QUEENSLAND BUILDING ACT• ALL RELEVANT LOCAL AUTHORITIES, BY-LAWS &PLANNING SCHEMES.

© COPYRIGHT-REPRODUCTION IN WHOLE OR PART ISSTRICTLY PROHIBITED WITHOUT PERMISSION

ISSUE AMENDMENT DATE

DATE DRAWN:

DD

DD

DD

DESIGN:

MECHANICAL DRAFTERS SERVICESA.B.N: 51 933 625 430PO Box 1613 Runaway Bay 4216Queensland, AustraliaE: [email protected]: www.mechanicaldrafters.com.au

-THESE PLANS ARE NOT TO BE USED FOR ENGINEER, ARCHITECTURAL OR CONSTRUCTION PURPOSE

1 : 20 @ A3

AWD-19

BUILDING DETAILS

479- WD 19 DUAL OCCUPANCY - FORPEOPLE WITH DISABILITIES

479- WD 19 DUALOCCUPANCY - FOR PEOPLEWITH DISABILITIES

479- WD 19 DUAL OCCUPANCY -FOR PEOPLE WITH DISABILITIES

02/11/2016

CUSTOM

TURNKEY HOME

1 : 20TYP. UNDER EAVES WALL EXTENSION

1 : 20PAVILION EAVE DETAIL

A WORKING DRAWING 02/11/2016

1 : 20ACCESS DETAIL

1 : 20TYP. GUTTER ON TOP OF WALL


Recommended