E.CK00108-3 Issue 3 Sheet 1/1 Edition: 03.20 Rotork Controls. All rights reserved. Subject to change without notice. Previous data sheets invalid with the issue of the latest data sheets. Due to production tolerance variation, the electrical values shown are averages compiled from Actuator production test data. Values are therefore provided for guidance only. Individual production tests are available on request (nominal load not included). Rotork Controls underwrite rated torque output only (specified tolerance -0/+10%) TITLE: MOTOR DATA. ISOLATING RANGE S2-15 MIN DUTY CYCLE, AC 3-240V/60Hz THREE PHASE MODELS: CK, CKA, CKC AC 3-240V/60Hz asynchronous motors. Short-time duty S2 - 15 min, based on nominal torque at 40C ambient temperature. Insulation class F. (H, under request). Motors are suitable for 60 starts/hour operation. Motor data is approximate, due to manufacturing tolerances, there may be deviations from the stated values. Permissible variation of the mains voltage: ±10 %. Permissible variation of the mains frequency: ±5 %Electric motors are provided with thermoswitches to protect the motor windings against overheating. Thermoswitches are embedded in the motor windings: If those thermoswitches are not connected, or by-passed, in the control circuit actuators will NO longer comply with the essential safety requirements, in that case Rotork warranty will lapse. CKC electric actuators with centronik- atronik unit, see datasheet for centronik-atronik unit current consumption.
Transcript
Page 1: E.CK00108-3 - Rotork · 2020. 3. 11. · Actuator production test data. Values are therefore provided for guidance only. Individual productio n tests are available on request (nominal

E.CK00108-3

Issue 3

Sheet 1/1 Edition: 03.20

Roto

rk C

ontr

ols.

All

right

s re

serv

ed. S

ubje

ct to

cha

nge

with

out n

otic

e. P

revi

ous

data

she

ets

inva

lid w

ith th

e is

sue

of th

e la

test

dat

a sh

eets

. Due

to p

rodu

ctio

n to

lera

nce

varia

tion,

the

elec

tric

al v

alue

s sh

own

are

aver

ages

com

pile

d fr

om

Actu

ator

pro

duct

ion

test

dat

a. V

alue

s ar

e th

eref

ore

prov

ided

for g

uida

nce

only

. Ind

ivid

ual p

rodu

ctio

n te

sts

are

avai

labl

e on

requ

est (

nom

inal

load

not

incl

uded

). Ro

tork

Con

trol

s un

derw

rite

rate

d to

rque

out

put o

nly

(spe

cifie

d to

lera

nce

-0/+

10%

)

TITLE: MOTOR DATA. ISOLATING RANGE S2-15 MIN DUTY CYCLE, AC 3-240V/60Hz THREE PHASE MODELS: CK, CKA, CKC

AC 3-240V/60Hz asynchronous motors. Short-time duty S2 - 15 min, based on nominal torque at 40C ambient temperature. Insulation class F. (H, under request). Motors are suitable for 60 starts/hour operation.

Motor data is approximate, due to manufacturing tolerances, there may be deviations from the stated values. Permissible variation of the mains voltage: ±10 %. Permissible variation of the mains frequency: ±5 %Electric motors are provided with thermoswitches to protect the motor windings against overheating. Thermoswitches are embedded in the motor windings: If those thermoswitches are not connected, or by-passed, in the control circuit actuators will NO longer comply with the essential safety requirements, in that case Rotork warranty will lapse. CKC electric actuators with centronik-atronik unit, see datasheet for centronik-atronik unit current consumption.

Recommended