+ All Categories
Home > Documents > Electrical BOQ

Electrical BOQ

Date post: 07-Jan-2016
Category:
Upload: rahul-kumar
View: 216 times
Download: 13 times
Share this document with a friend
Description:
Electrical BOQ
Popular Tags:

of 22

Transcript

BoQ Main BuildingBill of QuantitiesROYAL AUDIT AUTHORITY TRAINING CENTRE, TSIRANGRoyal Audit AuthorityName of work: Electrification & Allied WorksSub Title: Main BuildingS.No.BSR RefDESCRIPTIONQTY.UNITRATE (Nu.)AMOUNT (Nu.)AWIRING1Providing Wiring for the light point with 2x1.5sq. mmPVC insulated multistrand copper conductor cable in recessed 25mm dia HDPE pipe I/c all accessories as required for light point . Including providing accessories, Platinum brand switches 6A 1-gang / 2gang White colour Code CQ000501/02 for front cover. 6A 1 gang switch Code CQAT0006, Outer Plate for 1 module Code CQAT0501 for 2 module Code CQAT0502. Inner Plate for 1 module Code CQAT1501 for 2 module Code CQAT1502. Platinum brand switches 6A 4-gang White colour Code CQ000504 for front cover. 6A 1 gang switch Code CQAT0006, Outer Plate for 4 module Code CQAT0504. Inner Plate for 4 module Code CQAT1504 Havells/equivalent make. Use maximum 3 CFL fixture by 1 switch. Maximum 2single tube light fitting by 1 switch and double tube light fitting by 1 switch.1aWC0300Short Point175Point1bWC0301Medium Point154Point1cWC0302Long Point168Point2Providing Wiring for the 2-way light point with 2x1.5sq. mm PVC insulated multistrand copper conductor cable in recessed 25mm dia HDPE pipe I/c all accessories as required for twin control light point.2aWC0371Medium point6Point2bWC0372Long point12Point3WC0381Providing Wiring for the light point with 2x2.5sq. mm PVC insulated multistrand copper conductor cable in recessed 25mm dia HDPE pipe I/c all accessories as required for light circuit wiring .1350M4WC0381Providing Wiring for points in excess length above long points with 2x1.5sq. mm PVC insulated multistrand copper conductor cable in recessed 25mm dia HDPE pipe I/c all accessories as required.238M5WC0381Providing Wiring for Computer point with 2x2.5sq. mm PVC insulated multistrand copper conductor cable in recessed 25mm dia HDPE pipe I/c all accessories as required for Computer circuit wiring .1150M6WC0400Providing Wiring for the power point with 2x4sq. mm PVC insulated multistrand copper conductor cable in recessed 25mm dia HDPE pipe I/c all accessories as required for power wiring .1890M7WC0410Providing Wiring for Split Type Air Conditioner with 1.1kV grade 2x6sq. mm PVC insulated multistrand copper conductor cable in recessed HDPE Pipe including connections, and I/c all accessories as required from SDB to AC Point as per drawing.165MSUB-TOTAL FOR WIRINGBFITTING & ACCESSORIES1IL0170Supplying of Tubelight fitting surface mounted 1x36w/40w fluorscent. Code No.LHIF 71104011 White - Havells/Equivalent.15Each2IL0201Supplying of Tubelight fitting recess mounted 1x36w/40w fluorscent. Code No.LHCF 1136811 White - Havells/Equivalent.209Each3M/RSupplying of Surface mounted ceiling fitting square decorative downlighter with HF electronic ballast and translucent diffuser, pre-fitted with flat profile, for 1x25W CFL lamp LONON SQUARE White Code No.LHDC70125670 - Havells/Equivalent.53Each4M/RSupplying of Recess mounted ceiling fitting square decorative downlighter with HF electronic ballast and translucent diffuser, pre-fitted with flat profile, for 1x25W CFL lamp LONON SQUARE White Code No.LHOC68125370 - Havells/Equivalent.41Each5M/RSupplying of decorative wall light fixture foe 1x15W CFL White Code No.LHDL 06160099 Havells/Equivalent101Each6M/RSupplying of Recessed modular downlighter with drop glass for 1x70W MH DE-White Code No.LHOM74170399 Havells/Equivalent.5Each7SS0221Supplying of PVC Batten holder for 1 x 15W CFL lamp3Each8FN0002Supplying of ceiling fan 240volt AC 1200rpm with all accessories such as down rod, sweep 3nos. Canopy 2nos. Condenser, fan body & regulator etc. complete as required. - 1200mm sweep-SQCA appd.77Each9AC0016Providing & fixing 1.5tonne, Split Type Air Conditioner complete with all accessories including drilling holes for pipes, testing and commissioning etc. whatever is required at site to complete this job. SQCA appd.9Each10SS0076Supplying and fixing of RJ-11 Telephone Socket 1 gang shutter jack type Code No.CQAT 0355 white - Havells / Crabtree/Equivalent57Each11SS0177Supplying and fixing of RJ-45 Code No.ACPKMCW451 - Computer Socket white - Havells/Crabtree/Equivalent113Each12SS0205Supplying and fixing 6 Amp 6pin Switch Socket Combined shuttered having rectangle edge (Crabtree/ equivalent).5Each13SS0220Supplying and fixing 16 Amp 6pin Switch Socket Combined shuttered having rectangle edge (Crabtree/ equivalent).146Each14MRSupplying and fixing 25A Starter, 25A Socket, 25A plug white for 1x2500W Split Type Air Conditioner (Crabtree/ equivalent).9Each15SS0220Supplying and fixing 16 Amp 6pin Switch Socket Combined having both Flat & Round Pin White for Computer points (Crabtree/ equivalent).65Each16SS0220Supplying and fixing 3Pin 16 Amp Modular Recepticle Switch Socket Combined to be flush mounted on floor for Computer points (Crabtree/ equivalent).16Each17PO0015Providing & laying 25mm dia HDPE pipe for Telephone.480M18PO0015Providing & laying 25mm dia HDPE pipe for LAN.1150M19LS0126TLF lamp 36/40W224Each20MRCFL Lamp 15W104Each21MRCFL Lamp 25W94EachSUB-TOTAL FOR FITTING & ACCESSORIESCERECTION OF FITTING & ACCESS.1EI0041Installation, testing & commissioning of prewired fluorscent fittings of all types complete with all accessories and tubes etc. directly on wall / ceiling surface /recess mounted etc. as required.224Each2EI0002Erection of compact fluorscent fitting/wall brackets /ceiling fitting/ outdoor fittings/ Batten holder /musical call bell etc. I/c fixing of lamp connection, testing etc. as required.198Each3EI0096Installation, testing and commissioning of all size ceiling fan and regulator including wiring the down rod of standard length upto 300mm with 1.5sq.mm PVC insulated copper conductor77Each4EI0110Supplying extra down rod of G.I pipe (heavy duty) 15mm dia, 100mm long with 2x1.5sq.mm PVC insulated single core copper conductor cable, painting, cutting and threading etc. as required.77EachSUB-TOTAL FOR ERECTION of FITT & ACCEDSUBMAIN & CONTROL GEAR1Supplying of following sizes of 1.1 KV grade aluminium conductor PVC insulated and PVC sheathed armoured power cable.1aPC01503-1/2Cx25mm2 PVC Insulated UG cable Armoured AYFY from MCPB (Main control panel board) to SDB (Sub distribution board). Actual length will be as per site condition.195M1bPC01794Cx16mm2 PVC Insulated UG cable Armoured AYFY from MCPB (Main control panel board) to SDB (Sub distribution board). Actual length will be as per site condition.500M1cPC01232Cx10mm2 AYFY Computer points service connection at the SDB-5. Actual length will be as per site condition.48M2Supplying of the following items including all accessories whether specifically mentioned or not but required to make the Installation complete in all respect.SDB's under Normal Supply2aGB05394way TP&N Distribution board (DIN type) with metal door, 415 volts AC complete for SDB-1 (Ground Floor) (SQCA Appd)1EachGB036840Amp TP&N MCB, 415volt.(SQCA Appd)1EachGB02706Amp SPMCB4EachGB027216Amp SPMCB8Each2bGB054212way TP&N Distribution board (DIN type) with metal door, 415 volts AC complete for SDB-2 (Ground Floor) (SQCA Appd)1EachGB0196100Amp TP&N MCCB, 415volt. 25kA breaking capacity A.C complete (SQCA Appd)1EachGB027216Amp SPMCB36Each2cGB05418way TP&N Distribution board (DIN type) with metal door, 415 volts AC complete for SDB-3 (Ground Floor) (SQCA Appd)1EachGB0196100Amp TP&N MCCB, 415volt. 25kA breaking capacity A.C complete (SQCA Appd)1EachGB027216Amp SPMCB23EachGB027425Amp SPMCB1Each2dGB05394way TP&N Distribution board (DIN type) with metal door, 415 volts AC complete for SDB-4 (First Floor) (SQCA Appd)1EachGB036840Amp TP&N MCB, 415volt.(SQCA Appd)1EachGB02706Amp SPMCB4EachGB027216Amp SPMCB8Each2eGB054212way TP&N Distribution board (DIN type) with metal door, 415 volts AC complete for SDB-5 (First Floor) (SQCA Appd)1EachGB0196100Amp TP&N MCCB, 415volt. 25kA breaking capacity A.C complete (SQCA Appd)1EachGB027216Amp SPMCB34EachGB027425Amp SPMCB2Each2fGB05394way TP&N Distribution board (DIN type) with metal door, 415 volts AC complete for SDB-6 (First Floor) (SQCA Appd)1EachGB035563Amp TP&N MCB, 415volt. (SQCA Appd)1EachGB027216Amp SPMCB12Each2gGB05394way TP&N Distribution board (DIN type) with metal door, 415 volts AC complete for SDB-7 (Second Floor) (SQCA Appd)1EachGB036840Amp TP&N MCB, 415volt.(SQCA Appd)1EachGB02706Amp SPMCB3EachGB027216Amp SPMCB9Each2hGB054212way TP&N Distribution board (DIN type) with metal door, 415 volts AC complete for SDB-8 (Second Floor) (SQCA Appd)1EachGB0196100Amp TP&N MCCB, 415volt. 25kA breaking capacity A.C complete (SQCA Appd)1EachGB027216Amp SPMCB30EachGB027425Amp SPMCB6Each2iGB05394way TP&N Distribution board (DIN type) with metal door, 415 volts AC complete for SDB-9 (Second Floor) (SQCA Appd)1EachGB035563Amp TP&N MCB, 415volt. (SQCA Appd)1EachGB027216Amp SPMCB12Each2jGB035563Amp TP&N MCB, 415volt. (SQCA Appd)1Eachfor 9m Compound light.SDB's under Generator Supply2kGB054212way TP&N Distribution board (DIN type) with metal door, 415 volts AC complete for SDB-2 (Ground Floor) (SQCA Appd)1EachGB035563Amp TP&N MCB, 415volt. (SQCA Appd)1EachGB027110Amp SPMCB36Each2lGB05394way TP&N Distribution board (DIN type) with metal door, 415 volts AC complete for SDB-2 (Ground Floor) (SQCA Appd)1EachGB036840Amp TP&N MCB, 415volt.(SQCA Appd)1EachGB027110Amp SPMCB12Each2mGB05394way TP&N Distribution board (DIN type) with metal door, 415 volts AC complete for SDB-3 (Ground Floor) (SQCA Appd)1EachGB036863Amp TP&N MCB, 415volt. (SQCA Appd)1EachGB027110Amp SPMCB18Each2nGB05394way TP&N Distribution board (DIN type) with metal door, 415 volts AC complete for SDB-5 (First Floor) (SQCA Appd)1EachGB036840Amp TP&N MCB, 415volt.(SQCA Appd)1EachGB027110Amp SPMCB12Each2oGB05394way TP&N Distribution board (DIN type) with metal door, 415 volts AC complete for SDB-5 (First Floor) (SQCA Appd)1EachGB036840Amp TP&N MCB, 415volt.(SQCA Appd)1EachGB027110Amp SPMCB12Each2pGB05418way TP&N Distribution board (DIN type) with metal door, 415 volts AC complete for SDB-5 (First Floor) (SQCA Appd)1EachGB035563Amp TP&N MCB, 415volt. (SQCA Appd)1EachGB027110Amp SPMCB24Each2qGB05274way DP&N Distribution board (DIN type) with metal door, 230 volts AC SDB-5 (First Floor) (SQCA Appd)1EachGB031532Amp DP&N MCB, 230volt. (SQCA Appd)1EachGB027110Amp SPMCB4Each2rGB05394way TP&N Distribution board (DIN type) with metal door, 415 volts AC complete for SDB-6 (First Floor) (SQCA Appd)1EachGB036840Amp TP&N MCB, 415volt.(SQCA Appd)1EachGB027110Amp SPMCB12Each2sGB05394way TP&N Distribution board (DIN type) with metal door, 415 volts AC complete for SDB-8 (Second Floor) (SQCA Appd)1EachGB036840Amp TP&N MCB, 415volt.(SQCA Appd)1EachGB027110Amp SPMCB12Each2tGB05394way TP&N Distribution board (DIN type) with metal door, 415 volts AC complete for SDB-8 (Second Floor) (SQCA Appd)1EachGB036840Amp TP&N MCB, 415volt.(SQCA Appd)1EachGB027110Amp SPMCB12Each2uGB05394way TP&N Distribution board (DIN type) with metal door, 415 volts AC complete for SDB-9 (Second Floor) (SQCA Appd)1EachGB036840Amp TP&N MCB, 415volt.(SQCA Appd)1EachGB027110Amp SPMCB12Each2vGB05394way TP&N Distribution board (DIN type) with metal door, 415 volts AC complete for SDB-9 (Second Floor) (SQCA Appd)1EachGB036840Amp TP&N MCB, 415volt.(SQCA Appd)1EachGB027110Amp SPMCB12Each3GB0225Supplying of 160A Moulded case circuit breaker (MCCB) with electronic release, breaking capacity 36kA, 4pole 415volt, A.C complete with all accessories etc. as required at the Generator Panel.1Each4MRSupplying of 200A TPN Changeover 4pole 415volt, A.C complete with all accessories etc. as required at the Generator Panel.1Each5GB0241Supplying of 400A Moulded case circuit breaker (MCCB) with electronic release, breaking capacity 70kA, 4pole 415volt, A.C complete with all accessories etc. as required.1Each6GB0009Copper busbar chamber of size 300Amp 4x600mm including all accessories etc. at the Generator MCPB.1Set7GB0027Copper busbar chamber of size 600Amp 4x650mm including all accessories etc. at the Normal MCPB.1Set8M/RProviding and fixing electrical measuring instruments at the Main control panel board as per contract document specification - Voltmeter 0-500V - 1no.1Set- Ammeter 0- 400A - 1no.- Ammeter selector switch - 1no.- Voltmeter selector switch - 1no.- CT's and PT's- Indicating lamps - 4no.- HRC fuse 2A rating for avove-4no.9M/RProviding and fixing 400A 3-Phase 4 wire system Energy Meter at the apprppriate location in consultation with BPCL.1SetSUB-TOTAL FOR SUBMAIN & CONTRL GEAREROUTE MARKER1Providing and making route marker of size 600mmx600mm at bottom and 500mmx500mm at top with a thickness of 100mm including inscription as required.1aCL0070With cement concrete 1:2:4, 20mm stone aggregate / Steel plate.12eachSUB-TOTAL FOR ROUTE MARKERFCABLE TERMINATION WITH COMPRESSION GLAND1Installation, testing and commissioning of end termination with single/double compresion gland for PVC insulated and sheathed aluminium conductor cable of 1.1kV grade including connections etc. as required.1aCL01106/10/16/25mm dia34each1bCL011582/85mm dia16eachSUB-TOTAL FOR CABLE TERMINATION WITH COMPRESSION GLANDGINSTALLATION of SWITCH GEARS1Installation, testing and commissioning of TP switch fuse unit front drive four/miniature circuit breaker (DIN type) / Moulded case circuit breaker (MCCB) complete with all accessories to accommodate on/in prefabricated MS surface/Cubical control panel board including drilling holes, connections etc. as required.1aEI039025/32/40A DP MCB, 230V1each1bEI033840A TP&N MCB,415V11each1cEI034063A TP&N MCB,415V6each1dEI0425100A TP&N MCCB,415V3each1eEI0426125A TP&N MCCB,415V2each1fEI0460400A TP&N MCCB,415V2eachSUB-TOTAL FOR INSTALN. of SWITCH GEARSHINSTALLATION of DISTRIBUTION BOARD1Installation, testing and commissioning of TPN DB (DIN type) single/double door complete with all accessories to accommodate incoming MCB/MCCB/RCCB 4pole 32/40/63A sensitivity 30/100/300mA and outgoing SPMCB 6A/16A in prefabricated MS surface /MS cubical panel board including drilling holes, connections etc. as required.1aEI04954way DP DB1each1bEI05254way TPN DB13each1cEI05356way TPN DB1each1dEI05458way TPN DB2each1eEI055512way TPN DB4eachSUB-TOTAL FOR INSTALN. of DISTRIBUTION BOARDIMETAL PANEL BOARD1Providing and fixing of prefabricated panel board with minimum 50x50x6mm angle iron framework with horizontal and vertical intermediate members of flat iron 40x6mm and 24swg sheet cover for mounting of switchgears incoming/outgoing busbar chambers including driling holes, insulator, painting, denting, grouting etc. as required. for MCPB.1aEI0600Floor mounted cubical control panel board of welded construction1.2cu.m2Providing and fixing medium volt danger notice plate made of mild steel and painted with viterous enamelled white paint on both sides, and with inscription in signal red colour written as 440V/1100V in Dzongkha/English on front side as required on prefabricated MS surface/MS cubical control panel board on surface including drilling holes etc. as required.2aEI0610200mmx150mmx2mm3eachSUB-TOTAL FOR METAL PANEL BOARDJEARTHING & LIGHTNING PROTEC.1ET0075P/F of G.I. earth conductor of size 25mmx4mm for loop earthing as required. Including horizontal and four vertical drops for Lightning arrestor Loop connection for earthings etc.325M2ET0121Supplying & drawing 14SWG copper wire for loop earthing / earthing for electrical equipments.1580M3LG0002P/F of lightning arrestor final made of 25mm dia 900mm long GI tube having five prong at top with 85mm dia 6mm thick copper plate I/c holes and spring washer etc. as required.2M4ET0001Earthing with G.I earth plate 600mmx600mm x6mm thick I/c accessories & providing masonry enclosure with cover plate having locking arrangement & watering pipe. (For Lightning Arrestor) NOTE: This earthing shall be independently looped to each other and not to be interconnected with the electrical earthing.4Each5ET0001Earthing with G.I earth plate 600mmx600mm x6mm thick I/c accessories & providing masonry enclosure with cover plate having locking arrangement & watering pipe. (For General electrical earthing)4EachSUB-TOTAL FOR EARTNG & LIGHTNING PROTEC.KHDPE PIPE1Providing and Laying HDPE Pipe including trenching and refilling.1aPO001850mm dia for service cable, incoming main telephone cable.35M1bPO0022110mm dia for service cable connection to shaft.100M1cPO0025225mm dia for service cable connection and incoming main BPC cable30MSUBTOTAL FOR HDPE PIPELCOMPOUND LIGHT1Supplying of street light poles 50/60mm dia outer dia having base plate 250x250x5.4mm thick, entry hole of 40mm dia 1.1m from bottom and strude bolt as earth terminal, including providing 32mm dia MS/GI pipe for incoming and outgoing cable connection to junction box, complete as required.1aPA00035.5m 5.4mm thick as per drawing18.00Each2OL0070Supplying and fixing of Post Top Lantern Globe 480mm diameter HPC 16 with 1xHPL-N 80W, lamp holders, copper wound ballast, condenser, terminal block etc. (Philips/Equivalent/SQCA appd).18.00Each3OL0161Supplying and fixing of floodlight optal-1 New IP 66 suitable for 1x150W MH Code No.LHRM32115C36 Ordering Code No.LHRM32115C99 with 1x150W Metal Halide lamp with holder, copper wound ballast, condenser, terminal block etc. (Havells/Equivalent/SQCA appd).8.00Each4OL0146Supplying and fixing of floodlight JETA 3 New suitable for 1x70W HPL-N Code No.LHFM04170D36 Ordering Code No.LHFM04170D99 with 1x70W HPL-N lamp with holder, copper wound ballast, condenser, terminal block etc. (Havells/Equivalent/SQCA appd).6.00Each5Erection of street light pole 5.5m and 9m length with 40mm dia MS sleeve as inlet of power cable in cement concrete 1:3:6, 40mm stone aggregate foundation with cement concrete base 0.47mx0.47mx75mm thick 1:4:8 including excavation, centering & shuttering and filling providing props for pole etc. complete as required.5aPA0020At dead end4.00Each5bPA0021At middle24.00Each5cPA0022Junction of three way4.00Each6Supplying of street light poles 50/60mm dia outer dia having base plate 250x250x5.4mm thick, entry hole of 40mm dia 1.1m from bottom and strude bolt as earth terminal, including providing 32mm dia MS/GI pipe for incoming and outgoing cable connection to junction box, complete as required.6aMR9m pole as per drawing14.00Each7Supplying of junction box fabricated with 14swg MS sheet, removal cover plate with gasket for dust and vermin proof, 2 earthing terminals with nut, bolts and spring washer, 2 entry holes 16mm dia at bottom, 32mm dia hole for cable entry at back, including 4 way terminal block & HRC fuse unit with fuse of 6A with locking arrangement and finish coat painting complete with all accessories as required as per standard drawing/ / method.7aPA0105MS junction box outdoor duty32.00Each8Erection of junction box and pole light fixture including wiring with PVC insulated copper conductor cable 1.1kV grade 2x2.5sq.mm through the existing pole from junction box including erection of street light fixtures, lamps, connection, testing etc. complete as required.8aPA0050Junction box to lamp32.00Each9Supplying of following sizes of 1.1 KV grade aluminium conductor PVC insulated and PVC sheathed armoured power cable.9aPC01794Cx16mm2 AYFY (Procure as per site actual site measurement).160.00M9bPC01784Cx10mm2 AYFY (Procure as per actual site measurement).235.00M9cPC01774Cx6mm2 AYFY (Procure as per actual site measurement).535.00M10GB035563Amp TP&N MCB, 415volt. 25k A breaking capacity A.C complete (SQCA Appd)1.00Each11MRProviding & fixing Auto Timer for the compound lights Maxi Rex 4QT (Legrand).2.00Each12MRProviding & fixing 3 power poles contactor for the compound lights PC 37 K3N (Havells).2.00EachSUBTOTAL FOR COMPOUND LIGHTMFEEDER PILLAR - I1GB0241Supplying of 500A Moulded case circuit breaker (MCCB) with electronic release, breaking capacity 50kA, 4pole 415volt, A.C complete with all accessories etc. as required.1EachBPC STANDARD Feeder Pillar consisting of following components to be made2Providing and fixing of prefabricated panel board with minimum 50x50x6mm angle iron framework with horizontal and vertical intermediate members of flat iron 40x6mm and 24swg sheet cover for mounting of switchgears incoming/outgoing busbar chambers including driling holes, insulator, painting, denting, grouting etc. as required.2aEI0600Floor mounted cubical control panel board of welded construction1.50cu.m3GB0029Aluminium alloy/wrought aluminium/copper busbar chamber of size 600Amp 4x900mm including all accessories etc. for feeder pillar.1.00Set4Supplying of following sizes of 1.1 KV grade aluminium conductor PVC insulated and PVC sheathed armoured power cable.4aPC00603-1/2Cx400mm2 PVC insulated & sheathed UG cable armoured AYFY from BPC Sub-station to Clients Feeder Pillar. Actual length will be as per site condition.120M4bPC00593-1/2Cx300mm2 PVC insulated & sheathed UG cable armoured AYFY from Feeder Pillar to Main Control Panel Board. Actual length will be as per site condition.75M4dPC01503-1/2Cx25mm2 PVC Insulated UG cable Armoured AYFY from Feeder Pillar to Ex. Hostel No.2. Actual length will be as per site condition.65M5Laying of one number PVC insulated and sheathed power cable aluminium armoured 3-1/2 core to 4 core direct in the ground including excavation, sand cushing, protective covering and refilling the trenches etc. as required. However actual cable length may be determined at site before procurement.5aCL0002Above 6sq.mm to 25sq.mm45m5bCL0005Above 150sq.mm to 300sq.mm70m5cCL0006Above 300sq.mm to 630sq.mm90m6Providing and making route marker of size 600mmx600mm at bottom and 500mmx500mm at top with a thickness of 100mm including inscription as required.6aCL0070With cement concrete 1:2:4, 20mm stone aggregate / Steel plate.15.00each7M/RProviding and fixing electrical measuring instruments at the Main control panel board as per contract document specification - Voltmeter 0-500V - 1no.1.00SetAmmeter 0- 500A - 1no.Ammeter selector switch - 1no.Voltmeter selector switch - 1no.CT's and PT'sIndicating lamps - 4no.HRC fuse 2A rating for avove-4no.SUBTOTAL FOR FEEDER PILLAR-INFEEDER PILLAR - II1GB0241Supplying of 500A Moulded case circuit breaker (MCCB) with electronic release, breaking capacity 50kA, 4pole 415volt, A.C complete with all accessories etc. as required.1EachBPC STANDARD Feeder Pillar consisting of following components to be made2Providing and fixing of prefabricated panel board with minimum 50x50x6mm angle iron framework with horizontal and vertical intermediate members of flat iron 40x6mm and 24swg sheet cover for mounting of switchgears incoming/outgoing busbar chambers including driling holes, insulator, painting, denting, grouting etc. as required.2aEI0600Floor mounted cubical control panel board of welded construction1.50cu.m3GB0029Aluminium alloy/wrought aluminium/copper busbar chamber of size 600Amp 4x900mm including all accessories etc. for feeder pillar.1.00Set4Supplying of following sizes of 1.1 KV grade aluminium conductor PVC insulated and PVC sheathed armoured power cable.4aPC00603-1/2Cx400mm2 PVC insulated & sheathed UG cable armoured AYFY from BPC Sub-station to Clients Feeder Pillar. Actual length will be as per site condition.90M4bPC00553-1/2Cx120mm2 PVC insulated & sheathed UG cable armoured AYFY from Feeder Pillar to Hostel No.1. Actual length will be as per site condition.65M4cPC00553-1/2Cx120mm2 PVC insulated & sheathed UG cable armoured AYFY from Feeder Pillar to Hostel No.2. Actual length will be as per site condition.90M4dPC00533-1/2Cx70mm2 PVC insulated & sheathed UG cable armoured AYFY from Feeder Pillar to self Catering Bldng. No.1. Actual length will be as per site condition.40M4ePC00533-1/2Cx70mm2 PVC insulated & sheathed UG cable armoured AYFY from Feeder Pillar to self Catering Bldng. No.2. Actual length will be as per site condition.65M5Laying of one number PVC insulated and sheathed power cable aluminium armoured 3-1/2 core to 4 core direct in the ground including excavation, sand cushing, protective covering and refilling the trenches etc. as required. However actual cable length may be determined at site before procurement.5aCL0003Above 25sq.mm to 70sq.mm85m5bCL0004Above 70sq.mm to 150sq.mm135m5cCL0006Above 300sq.mm to 630sq.mm76m6Providing and making route marker of size 600mmx600mm at bottom and 500mmx500mm at top with a thickness of 100mm including inscription as required.6aCL0070With cement concrete 1:2:4, 20mm stone aggregate / Steel plate.15.00each7M/RProviding and fixing electrical measuring instruments at the Main control panel board as per contract document specification - Voltmeter 0-500V - 1no.1.00SetAmmeter 0- 400A - 1no.Ammeter selector switch - 1no.Voltmeter selector switch - 1no.CT's and PT'sIndicating lamps - 4no.HRC fuse 2A rating for avove-4no.SUBTOTAL FOR FEEDER PILLAR-IIOFIRE DETECTION & ALARM SYSTEM1WC0381Providing Wiring for fire detection and alarm system with 2x1.5sq. mm PVC insulated multistrand copper conductor fire retardent cable in recessed 25mm dia HDPE pipe I/c all accessories as required.675M2WC0381Adressable Fire Alarm Control ,198-Point on One Signaling Line Circuit (SLC) Loop, 24 VDC , UL Listed / International brand- Honeywell, Edward.1Each3MRAddressable Low-Profile Photoelectric Smoke Detector- UL listed / International brand - Honeywell, Edward.75Each4MRAddresable Manual Pull Station , Dual -Action ,Lexan , Key Lock - UL listed / International brand - Honeywell, Edward.14Each5MRAddressable Control Module with Conventional Hooter - UL listed / International brand - Honeywell, Edward.8Each6MR5kg DCP Fire Extinguisher (ISI certified)15Each7MR4.5kg CO2 Extinguisher (ISI certified)15Each8MRInstallation, testing and commissioning including maintenance manual and first hand training at site.1LotSUBTOTAL FOR FIRE DETECTION & ALARM SYSTEMPD/G SET1MRProviding, Installation, testing and1.00setcommissioning of UK make P150-2kVA DG set in sound attenuatedand weather proof canopy.The DG set consists of engine, soundattenuated and weather proof canopypower wizard control panel 2.1, Anti-vibration mounting pads, base frame,battery, battery leads, battery charger,50% Auto freeze, Anti condensationheater, coolant heater, lubricant oil.FG Wilson / Equivalent.2MRProviding & fixing of auto load transfer1.00setcontrol panel with motorized switch.FG Wilson / equivalent3MRClearing charge, load-unloading1.00LSTransportation cost to the site.4MRBST & other taxes as applicable1.00LS5MROther related civil & electrical works1.00LSwith fuel provision for testing theD/G set.6MRInstallation, testing & commissioning1.00LSSUB-TOTAL FOR D/G SETQCOMPUTER NETWORK1MRCAT6 Data cable15.00box2 2aMRSwitch: 24 PORT GIGA ETHERNET SWITCH4.00Each2bSwitch: 16 PORT GIGA ETHERNET SWITCH1.00Each3 3aMRCAT6: Surface Mount Box with Information Outlet; Simplex113.00Each3bCAT6: Factory Crimped Mounting Cord; 7 ft113.00Each4 4aMRCAT6: Factory Crimped Mounting Cord; 7 ft113.00Each4bCAT6: 24Port patch Panel5.00Each5MRWall Mount Rack with Glass Cover; 6U5.00Each6 6aMRMiscellaneous Items:LS6bPVC Cassing Capping & Accessories, if required.LS7MRInstallation & Configuration and Commissioning Charges: Installation & Configuration of Wireless System; termination/testing of all extensionsLSSUB-TOTAL FOR COMPUTER NETWORKREPABX SYSTEMEPABX Systems: Equipped with 08 CO (Trunk-Telecom) + 64 Extensions (Internal).1.00set1MRDigital Key Telephone Instrument:1(Operator Phone): Make: PanasonicEach2MRVoltage Stabiliser1.00Each3MRBattery Backup1.00set4MRTelehone57.00Each5MRMain Distribution Frame (50 Pairs) (MDF) with KRONE Block Connectors and GD Tube Lightning Protectors for CO Lines5.00set6MRTelephone cable Cat-5LS7MRMiscellaneous ItemsLS8MRInstallation & Configuration and Commissioning Charges: Installation & Configuration of EPABX System; termination/ testing of all extensionsLS9MRPVC Pipes, Casing capping and other cable management accessories if required.1Lot10Installation & commissioning of above system1LSSUB-TOTAL FOR EPABXTOTAL FOR ELECTRICAL, FIRE DETECTION & ALARM SYSTEM, EPABX & LAN NETWORK (Nu.)In Words:.

Page &P of &N


Recommended