bytics engineering ag STS404 Bachweg 5 CH-8133 Esslingen Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 1 von 25 Order number DEZ.14.009-1 Project number 110-001-1e-1 EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando Unit under test: Apu.1c with serial number Date of receipt of the unit under test: 26.02.2014 Test date: 26.02.2014 Scope of testing (see 1.6): Emission according to EN 61000-6-3 (2007) domestic environments Conducted disturbances according to EN 55022 (2006) Immunity according to EN 61000-6-2 (2005) industrial environments ESD according to EN 61000-4-2 (2009) Immunity to radiated EM field according to EN 61000-4-3 (2008) Burst according to EN 61000-4-4 (2010) Surge according to EN 61000-4-5 (2006) Immunity to conducted disturbances according to EN 61000-4-6 (2009) Result of the test: The unit under test is in conformity with the standards mentioned above. Position Name Visum Date Head of the test centre S. Mathez Deputy M. Müller-Ferrando Test engineer S. Mathez Only the signed original of this test report is binding. This document may not be copied in whole or in part.
Transcript
Page 1: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

bytics engineering ag STS404

Bachweg 5 CH-8133 Esslingen

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 1 von 25

Order number DEZ.14.009-1 Project number 110-001-1e-1

EMC Test Report

Apu.1c PC Engines GmbH, CH-8152 Glattbrugg

S. Mathez, M. Müller-Ferrando

Unit under test: Apu.1c with serial number Date of receipt of the unit under test: 26.02.2014 Test date: 26.02.2014 Scope of testing (see 1.6): Emission according to EN 61000-6-3 (2007) domestic environments Conducted disturbances according to EN 55022 (2006) Immunity according to EN 61000-6-2 (2005) industrial environments ESD according to EN 61000-4-2 (2009) Immunity to radiated EM field according to EN 61000-4-3 (2008) Burst according to EN 61000-4-4 (2010) Surge according to EN 61000-4-5 (2006) Immunity to conducted disturbances according to EN 61000-4-6 (2009) Result of the test: The unit under test is in conformity with the standards mentioned

above.

Position Name Visum Date

Head of the test centre S. Mathez

Deputy M. Müller-Ferrando

Test engineer S. Mathez

Only the signed original of this test report is binding. This document may not be copied in whole or in part.

Page 2: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 2 von 25

Contents

1 GENERAL ................................................................................................................. 3

1.1 Test centre ..........................................................................................................................................3

1.2 Customer ............................................................................................................................................3

1.3 Unit under test ....................................................................................................................................3

1.4 Interfaces and operating states ..........................................................................................................3

1.5 Description of unit under test (UUT) ...................................................................................................4

1.6 Scope of testing ..................................................................................................................................4 1.6.1 Emissions according to EN 61000-6-3 (2007) for domestic environments .................................4 1.6.2 Immunity according to EN 61000-6-2 (2005) for industrial environments ...................................4

1.7 Advice .................................................................................................................................................4

2 TESTS ....................................................................................................................... 5

2.1 Electromagnetic disturbances ............................................................................................................5 2.1.1 Terminal disturbance voltage (EN 55022) ...................................................................................5

2.2 Immunity .......................................................................................................................................... 13 2.2.1 Electrostatic discharge immunity (EN 61000-4-2) .................................................................... 13 2.2.2 Radiated, radio-frequency, electromagnetic field immunity (EN 61000-4-3) ........................... 15 2.2.3 Electrical fast transient/burst immunity (EN 61000-4-4) ........................................................... 17 2.2.4 Surge immunity (EN 61000-4-5)............................................................................................... 20 2.2.5 Immunity to conducted disturbances, induced by RF fields (EN 61000-4-6) ........................... 23

Page 3: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 3 von 25

1 General 1.1 Test centre bytics engineering ag Technoparkstr. 1 CH-8005 Zürich 1.2 Customer PC Engines GmbH Flughofstrasse 58 CH-8152 Glattbrugg 1.3 Unit under test Unit under test:

Manufacturer: PC Engines GmbH Model: Apu.1c Serial number:

1.4 Interfaces and operating states For the EMC-tests are the following interfaces relevant:

Interface Electrical proper-ties

Mechanical properties

Maximum length

AC-Power

U = 230 VAC P = 24 W

copper -

Ethernet

Signal Shielded 100 m

USB

Signal Shielded 3 m

Serial

Signal Copper 3 m

Operating state of the unit under test:

- Transfer mode

Page 4: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 4 von 25

1.5 Description of unit under test (UUT)

1.6 Scope of testing 1.6.1 Emissions according to EN 61000-6-3 (2007) for domestic environments Test Limit Test passed

Main terminal (AC) and signal line disturbance voltage 150kHz...30MHz

EN 55022 (2006) Class A

yes

Harmonic currents below 16A EN 61000-3-2 (2008)

Not applica-ble

1

Voltage variations and Flicker below 16A

EN 61000-3-3 (2008)

Not applica-ble

2

1.6.2 Immunity according to EN 61000-6-2 (2005) for industrial environments Test Limit Test passed

Electrostatic discharge immunity On the cases and plugs with air- and contact discharge

EN 61000-4-2 (2009) Test level 3 4kV Contact discharge 8kV Air discharge

yes

Radiated, radio frequency, electro-magnetic field immunity 80...2700MHz, 80% AM (1kHz) Unit under test with all wires

EN 61000-4-3 (2008) Test level 3 80MHz...1GHz, 10V/m 1GHz...2GHz, 3V/m 2GHz...2.7GHz, 1V/m

yes

Electrical fast transient/burst immunity 5/50ns, 5kHz Power-/Sensor line Main terminal (AC) and signal lines

EN 61000-4-4 (2010) Test level 3 (1kV/2kV)

yes

Surge immunity 1.2/50E-6s Main terminal (AC)

EN 61000-4-5 (2006) Test level 3 (1kV / 2kV)

yes

Immunity to conducted disturbances, induced by radio frequency fields 150kHz...80MHz, 80% AM (1kHz) Main terminal (AC) and signal lines

EN 61000-4-6 (2009) Test level 3 (10V)

yes

Power frequency magnetic field immunity test

EN 61000-4-8 (2010)

Not applica-ble

3

Voltage dips and Interruptions EN 61000-4-11 (2004)

Not tested4

1.7 Advice The inspection results in this report refer exclusively to the unit under test that in 1.3 mentioned.

1 Power < 75W and no harmonics expected

2 No voltage variations expected

3 No magnetic sensors inside

4 Tested at PC Engines

Page 5: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 5 von 25

2 Tests 2.1 Electromagnetic disturbances 2.1.1 Terminal disturbance voltage (EN 55022) Test setup:

See standard EN 55022 and test instruction bytics engineering ag document 80-002-7.

Figure 1: 230VAC

Figure 2: USB

Page 6: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 6 von 25

Figure 3: RS232

Figure 4: Ethernet

Page 7: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 7 von 25

Instruments and tools: - Receiver R&S ESU8 T0605 - LISN PMM L3-25 T0010 - Current probe R&S EZ17 T0020 - RF cable from Antenna

to anechoic chamber H&S RG214/U T0029 - RF cable from anechoic

chamber to receiver H&S RG214/U T0030 Test procedures:

See standard EN 55022 and test instruction bytics engineering ag document 80-002-7. Expanded uncertainty with a confidence level of 95%:

Uncertainty = 3.1 dB Requirement: Group 1, Class B (domestic environment) Unit under test: Apu.1c Operating state: Transfer mode Result of the test: The unit under test is in conformity with the standards according to class B.

Page 8: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 8 von 25

Test results:

Auftragsnr.: DEZ.14.009

Prüfling: apu1c

Betriebszustand: Normal mode

Leitung: L

Scan Start: Scan Stop: Detector: Transducer:

Start Frequency

Stop Frequency

Step Size

Res BW

Meas Time

RF Atten

Preamp

Input

Stepped Scan (1 Range)

150 kHz 30 MHz Trace 1: MAX PEAK Trace 2: Average LISN

150.000000 kHz 30.000000 MHz 4.00 kHz 9.00 kHz 1 ms 10 dB 0 dB INPUT2

Final Measurement

Meas Time: Margin:

1 s 0 dB

Peaks: 0

Page 9: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 9 von 25

Auftragsnr.: DEZ.14.009

Prüfling: apu1c

Betriebszustand: Normal mode

Leitung: N

Scan Start: Scan Stop: Detector: Transducer:

Start Frequency

Stop Frequency

Step Size

Res BW

Meas Time

RF Atten

Preamp

Input

Stepped Scan (1 Range)

150 kHz 30 MHz Trace 1: MAX PEAK Trace 2: Average LISN

150.000000 kHz 30.000000 MHz 4.00 kHz 9.00 kHz 1 ms 10 dB 0 dB INPUT2

Final Measurement

Meas Time: Margin:

1 s 0 dB

Peaks: 0

Page 10: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 10 von 25

Auftragsnr.: DEZ.14.009

Prüfling: apu1c

Betriebszustand: Normal mode

Leitung: Ethernet

Scan Start: Scan Stop: Detector: Transducer:

Start Frequency

Stop Frequency

Step Size

Res BW

Meas Time

RF Atten

Preamp

Input

Stepped Scan (1 Range)

150 kHz 30 MHz Trace 1: MAX PEAK Trace 2: Average EZ17

150.000000 kHz 30.000000 MHz 4.00 kHz 9.00 kHz 1 ms 10 dB 0 dB INPUT2

Final Measurement

Meas Time: Margin:

1 s 0 dB

Peaks: 0

Page 11: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 11 von 25

Auftragsnr.: DEZ.14.009

Prüfling: apu1c

Betriebszustand: Normal mode

Leitung: RS232

Scan Start: Scan Stop: Detector: Transducer:

Start Frequency

Stop Frequency

Step Size

Res BW

Meas Time

RF Atten

Preamp

Input

Stepped Scan (1 Range)

150 kHz 30 MHz Trace 1: MAX PEAK Trace 2: Average EZ17

150.000000 kHz 30.000000 MHz 4.00 kHz 9.00 kHz 1 ms 10 dB 0 dB INPUT2

Final Measurement

Meas Time: Margin:

1 s 0 dB

Peaks: 0

Page 12: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 12 von 25

Auftragsnr.: DEZ.14.009

Prüfling: apu1c

Betriebszustand: Normal mode

Leitung: USB

Scan Start: Scan Stop: Detector: Transducer:

Start Frequency

Stop Frequency

Step Size

Res BW

Meas Time

RF Atten

Preamp

Input

Stepped Scan (1 Range)

150 kHz 30 MHz Trace 1: MAX PEAK Trace 2: Average EZ17

150.000000 kHz 30.000000 MHz 4.00 kHz 9.00 kHz 1 ms 10 dB 0 dB INPUT2

Final Measurement

Meas Time: Margin:

1 s 0 dB

Peaks: 0

Page 13: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 13 von 25

2.2 Immunity 2.2.1 Electrostatic discharge immunity (EN 61000-4-2) Climatic conditions:

Ambient temperature: 21.6 °C Relative humidity: 32.2 °C Air pressure: 948.2 mbar

Test setup:

See standard EN 61000-4-2 and test instruction bytics engineering ag document 80-002-1.

Figure 5: 230VAC

Instruments and tools:

- ESD Generator EM-Test Dito T0003 - Meteo Station Thommen HM30 T0066 - Temp.-/Humidity sensor Rotronic HP100A T0067

Test procedures:

See standard EN 61000-4-2 and test instruction bytics engineering ag document 80-002-1. Uncertainty:

The test instruments are in conformity with the standards. Requirement:

Conformity with performance criteria B at ±4kV contact- and ±8kV air discharge.

Page 14: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 14 von 25

Performance criteria A: The unit under test shall continue to operate as in-tended. No degradation of performance or loss of function is allowed below a performance level speci-fied by the manufacturer.

Performance criteria B: The unit under test shall continue to operate as in-tended. No degradation of performance or loss of function is allowed below a performance level speci-fied by the manufacturer. During the test, degradation of performance is however allowed.

Unit under test: Apu.1c Operating state: Transfer mode Function control: The function was controlled by the notebook Result of the test:

The unit under test is in conformity with the standards according to performance criteria A.

Test results:

Contact discharge direct Performance of the unit under test

± 2kV Normal performance during the test

± 4kV Normal performance during the test

Position of discharge Screws, case and plugs of the unit under test

Contact discharge indi-rect

Performance of the unit under test

± 2kV Normal performance during the test

± 4kV Normal performance during the test

Position of discharge Vertical and horizontal couple plane

Air discharge direct Performance of the unit under test

± 4kV Normal performance during the test

± 6kV Normal performance during the test

± 8kV Normal performance during the test

Position of discharge All isolated parts of the unit under test

Page 15: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 15 von 25

2.2.2 Radiated, radio-frequency, electromagnetic field immunity (EN 61000-4-3) Test setup:

See standard EN 61000-4-3 and test instruction bytics engineering ag document 80-002-2.

The tests were executed in an anechoic chamber at a test distance of 3m be-tween the unit under test and the antenna.

Figure 6: Position 0°

Instruments and tools:

- BiConiLog Antenna EMCO3142C T0069 - Signal generator HP 8648D T0017 - Amplifier ar 50W1000A T0013 - Amplifier ar 150A220 T0012 - Amplifier ar 50S1G4A T0572 - RF relay MTS KRM4 T0197 - RF relay MTS KRM4 T0570 - RF cable from antenna

to anechoic chamber H&S RG214/U T0029 - RF cable from anechoic

chamber to RF relay T0197 H&S RG214/U T0030 - RF cable from amplifier

50W1000A to HF relay T0197 H&S RG214/U T0032 - RF cable from signal generator

to RF relay T0570 H&S RG223/U T0031 - RF cable from amplifier

150A220 to RF relay T0197 H&S RG214/U T0068 - RF cable from RF relay T0570

to amplifier 150A220 H&S RG223/U T0539

Page 16: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 16 von 25

- RF cable from RF relay T0570 to amplifier 50W1000A H&S RG223/U T0540

- RF cable from RF relay T0570 to amplifier 50S1G4A H&S RG223/U T0574

- RF cable from RF relay T0197 to amplifier 50S1G4A H&S S04272B T0573

- Absorbing ferrite clamp R. Lüthi FTC 40x15E T0070 Test procedures:

See standard EN 61000-4-3 and test instruction bytics engineering ag document 80-002-2. Expanded uncertainty with a confidence level of 95%:

Uncertainty = 3.4dB Requirement:

Conformity with performance criteria A at 10 V/m (80MHz...1GHz), 3 V/m (1GHz...2GHz) and 1 V/m (2GHz...2.7GHz)

Performance criteria A: The unit under test shall continue to operate as in-

tended. No degradation of performance or loss of function is allowed below a performance level speci-fied by the manufacturer.

Unit under test: Apu.1c Operating state: Transfer mode Function control: The function was controlled by the notebook Field strength: 10 V/m (80MHz...1GHz); 3 V/m (1GHz...2GHz)

1 V/m (2GHz...2.7GHz) Frequency step: 1% Amplitude modulation: 80% 1kHz Dwell time: 0.5s Antenna height: 1m Polarisation: horizontal, vertical Result of the test:

The unit under test is in conformity with the standards according to performance criteria A.

Test results:

Frequency (MHz) Performance of the unit under test

80 – 2700 Normal performance during the test

Page 17: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 17 von 25

2.2.3 Electrical fast transient/burst immunity (EN 61000-4-4) Test setup:

See standard EN 61000-4-4 and test instruction bytics engineering ag document 80-002-3.

Figure 7: 230VAC

Figure 8: Ethernet line

Page 18: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 18 von 25

Figure 9: RS232 line

Figure 10: USB line

Instruments and tools:

- Burst generator EM-Test UCS500 T0002 - Capacitive coupling clamp EM-Test HFK T0004

Page 19: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 19 von 25

Test procedures: See standard EN 61000-4-4 and test instruction bytics engineering ag

document 80-002-3. Uncertainty:

The test instruments are in conformity with the standards. Requirement:

Conformity with performance criteria B at ±2kV on AC-power line and ±1kV on signal lines. Performance criteria A: The unit under test shall continue to operate as in-

tended. No degradation of performance or loss of function is allowed below a performance level speci-fied by the manufacturer.

Performance criteria B: The unit under test shall continue to operate as in-tended. No degradation of performance or loss of function is allowed below a performance level speci-fied by the manufacturer. During the test, degradation of performance is however allowed.

Unit under test: Apu.1c Operating state: Transfer mode Function control: The function was controlled by the notebook Voltage: ±1kV/±2kV Burst duration: 15ms Pulse form: 5ns/50ns Frequency: 5kHz Coupling network: Internal coupling network, capacitive coupling clamp Result of the test:

The unit under test is in conformity with the standards according to performance criteria A.

Test results:

Point of disturbance / disturbance voltage

Performance of the unit under test

AC line / ±2kV Normal performance during the test

AC line / ±1kV Normal performance during the test

AC line / ±500V Normal performance during the test

Ethernet line / ±1kV Normal performance during the test

Ethernet line / ±500V Normal performance during the test

RS232 line / ±1kV Normal performance during the test

RS232 line / ±500V Normal performance during the test

USB line / ±1kV Normal performance during the test

USB line / ±500V Normal performance during the test

Page 20: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 20 von 25

2.2.4 Surge immunity (EN 61000-4-5) Test setup:

See standard EN 61000-4-5 and test instruction bytics engineering ag document 80-002-4.

Figure 11: 230VAC

Figure 12: Ethernet line

Page 21: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 21 von 25

Instruments and tools: - Surge generator EM-Test UCS500 T0002 - Coupling network EM-Test CNV504 T0005

Test procedures:

See standard EN 61000-4-5 and test instruction bytics engineering ag document 80-002-4. Uncertainty:

The test instruments are in conformity with the standards. Requirement:

Conformity with performance criteria B at surge on AC-power line (±1kV line to line, ±2kV line to earth) and signal lines (±1kV line/shield to earth).

Performance criteria A: The unit under test shall continue to operate as in-

tended. No degradation of performance or loss of function is allowed below a performance level speci-fied by the manufacturer.

Performance criteria B: The unit under test shall continue to operate as in-tended. No degradation of performance or loss of function is allowed below a performance level speci-fied by the manufacturer. During the test, degradation of performance is however allowed.

Unit under test: Apu.1c Operating state: Transfer mode Function control: The function was controlled by the notebook Voltage: ±1 kV/±2 kV Pulse form: Open circuit voltage 1.2/50E-6s Short circuit current 8/20E-6s Coupling network: Internal coupling network, CNV504

Page 22: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 22 von 25

Result of the test: The unit under test is in conformity with the standards according to performance criteria A.

Test results:

Point of disturbance / disturbance voltage

Performance of the unit under test

AC-line Line to earth / ±2kV

Normal performance during the test

AC-line Line to line / ±1kV

Normal performance during the test

AC-line Line to line / ±500V

Normal performance during the test

Ethernet line shield to earth / ±1kV

Normal performance during the test

Ethernet line shield to earth / ±500V

Normal performance during the test

Page 23: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 23 von 25

2.2.5 Immunity to conducted disturbances, induced by RF fields (EN 61000-4-6) Climatic conditions:

Ambient temperature: 21.9 °C relative humidity: 28.5 % Air pressure: 947.7 mbar

Test setup:

See standard EN 61000-4-6 and test instruction bytics engineering ag document 80-002-5.

Figure 13: 230VAC

Figure 14: Ethernet

Page 24: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 24 von 25

Instruments and tools: - Signal generator HP 8648D T0017 - Amplifier ar 150A220 T0012 - Coupling network R. Lüthi CDN801-S8 T0590 - Coupling network R. Lüthi CDN801-M2/M3 T0006 - RF relay MTS KRM4 T0197 - RF relay MTS KRM4 T0570 - RF cable from attenuator

to anechoic chamber H&S RG214/U T0029 - RF cable from anechoic

chamber to RF relay T0197 H&S RG214/U T0030 - RF cable from signal generator

to RF relay T0570 H&S RG223/U T0031 - RF cable from amplifier

150A220 to RF relay T0197 H&S RG214/U T0068 - RF cable from RF relay T0570

to amplifier 150A220 H&S RG223/U T0539 - RF cable from attenuator

to CDN/EM101 H&S S04272B T0541 - Attenuator JFW 50FHAO-010-200 T0034 - Meteo Station Thommen HM30 T0066 - Temp.-/Humiditysensor Rotronic HP100A T0067

Test procedures:

See standard EN 61000-4-6 and test instruction bytics engineering ag document 80-002-5. Expanded uncertainty with a confidence level of 95%: Uncertainty = 1.2dB Requirement:

Conformity with performance criteria A at 10V on AC and signal line.

Performance criteria A: The unit under test shall continue to operate as in-tended. No degradation of performance or loss of function is allowed below a performance level speci-fied by the manufacturer.

Page 25: EMC Test Plan - Motherboardsresources.mini-box.com/online/MBD-P-ALIX-APU1D/apu1c-emc.pdf · EMC Test Report Apu.1c PC Engines GmbH, CH-8152 Glattbrugg S. Mathez, M. Müller-Ferrando

Document: 110-001-1e-1_DEZ.14.009-1.docx Seite 25 von 25

Unit under test: Apu.1c Operating state: Transfer mode Function control: The function was controlled by the notebook Voltage: 10V Amplitude modulation: 80% 1kHz Frequency step: 1% Dwell time: 0.5s Coupling network: CDN-801M2/M3, CDN-801-S8

Result of the test: The unit under test is in conformity with the standards according to performance criteria A.

Test results:

Point of disturbance Frequency (MHz) Performance of the unit under test

AC line 0.15 – 80 Normal performance during the test

Ethernet 0.15 – 80 Normal performance during the test


Recommended