40
Product catalogue October 2011
Transcript
Page 1: En Catalogue

Product catalogueOctober 2011

Page 2: En Catalogue

Fenix was founded in 1990 as one of the fi rst private companies in the Czech Republic following the “Velvet” Revolution. The fi rst items produced were the successfully marketed ECOSUN electric radiant heating panels, however, as market demand increased these products were followed by ECOFLEX electric convectors, ECOFLOOR heating cables and mats and ECOFILM heating fi lms. The company also offers a wide range of supplementary products including heating system controls, cable kits and cable mats. With the increase in demand the structure of the company developed – for the reason of retaining maximum fl exibility a holding company structure was chosen, with individual and independent members.

The following companies were incorporated successively: Fenix s.r.o. – plant producing electrical heating systems; Fenix Trading s.r.o. – trading company; Fenix Slovakia s.r.o. – production and trading company, representing FENIX in Slovakia; Fenix Group a.s. – a company which provides property management and services (strategic planning, administration of property, economic and fi nancial services); Flexel International Ltd. – manufacturing and trading company located in the United Kingdom. In 2008 FENIX Holding – acquired the production and trading company Aztec Europe Ltd., – manufacturer of special applications, such as mirror demisting heaters, vivarium heaters, caravan and

Page 3: En Catalogue

ECOSUN – radiant heating panelslow and high temperature radiant ceiling panels

pages 4–6

MR – marble radiant panels for residential,commercial and individual application

page 7

GR – glass radiant panels for residential, commercial and individual application

pages 8–9

IRC PANELS – radiant heating for infrared cabins pages 10–11

ECOFLOOR – heating cable systemsheating cable circuits and cable mats, complete fl oor heating installation kits,

deicing gutters and eaves troughs, snow-melting, de-icing outdoor surfaces, frost protection of pipes

pages 12–25

ECOFILM – heating fi lm systemsE-set – underfl oor heating, kit for DIY installation

F – underfl oor heating fi lmC – radiant ceiling heating fi lm,

MHF – mirror fogging preventionpages 26–29

ULTRATHERM – heating for vivariums and terrariums pages 30–31

ECOFLEX – electric convectorsclassic and glass convection heaters

pages 32–33

THERMOSTATS AND CONTROLSregulation unit, control unit, room and fl oor sensors, and

regulators for reduction of main circuit breaker valuepages 34–36

STORAGE HEATERSstatic and dynamic storage heaters

page 37

ATLANTIC – storage water heaters10 – 150 L volume

page 38

SUPPLEMENTARY PRODUCTShand dryers, towel radiators

page 38

mobile home heating equipment. At the end of 2009/in early 2010 Fenix Holding acquired two other production and trading companies: ACSO – production and trading company with its headquarters in France; CEILHIT –producer of heating cables and trading company with its headquarters in Spain, covering the market in Spain, Portugal and South America.

Presently, the company Fenix Holding s.r.o. is one of the largest European producers of surface electric heating systems, and currently exports to over 52 countries worldwide.

Page 4: En Catalogue

4

Principle of infrared heatingWhereas in convection heating the air is warmed by a con-vector which then transfers heat as it fl ows over the objects that are to be heated (walls, furniture), Radiant heating panels transfer heat mainly through radiant energy. Upon encountering objects (walls, furniture, fl oors), radiant energy is partially refl ected (approx. 15 %), the majority (approx. 85 %) is absorbed by the objects. This radiant energy is converted to heating energy as it raises the temperature of the objects, which then transfer heat to the cooler air by convection. Thanks to unique technology Silicating, high temperature radiant panels reach high emissivity up to 0,98 mu.

Unique technologiesFenix utilises unique state-of-the art technology in respect of the fi nished panel surfaces. (Thermoquartz and Thermocrystal for low temperature panels and Silicating for high temperature panels).

ECOSUN®

radiant heating panels

The principles mentioned create the following advantages:

the surface of the radiant panel generates a heat fl ow whose spectrum is in the wavelength not greater than 5 micrometers and is thus absorbed to a large degree by the human body: people are therefore heated in a manner similar to the objects in the room. when the radiant heat fl ow increases the temperature of the objects in the room of 20–22 °C, comfort conditions are achieved even with air temperatures of 18–19 °C which can lead to energy savings of 18–24 %. radiant panels permit the temperature distribution in a room to be more vertically balanced giving a 1–2 degree difference between the fl oor and the ceiling (for convection heating the difference is given as 1 °C per metre of height, 30–50 cm of height). there is less fl ow movement therefore dust particles due to brownian movement are less thus reducing the risk of illnesses – asthma, mucous membrane infection, etc. increased wall temperatures mean a lower possibility of surface condensation, albeit the humidity in the room is not lowered.glass is not “transparent” (we might say “transthermant”) when it comes to radiation with wavelengths over 3 and thus the radiant fl ow is not lost through windowpanes. the panels do not require maintenance

Convection heatingRadiant heating by ECOSUN

Page 5: En Catalogue

5

LOW TEMPERATURE PANELS

ECOSUN K+ – heating panel used for warming church pews, desks in offi ces and administrative buildings. They can be hung on a wall in the standard way; for installation on the ceiling it is necessary to order a ceiling frame. Class I.Basic colour: brown (RAL 8017), white (RAL 9016) Connection cable: 50 cm for 100–270 K+, 75 cm for 330–400K+

TYPE [W] [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance [m] Quantity on pallet Cat. No.ECOSUN 100 K+ 100

230 IP 44

500×320×30 2,5

vertical or horizontal position

60 5401200ECOSUN 200 K+ 200 750×320×30 3,7 45 5401205ECOSUN 270 K+ 270 1000×320×30 5,2 30 5401210ECOSUN 330 K+ 330 1250×320×30 6,6 30 5401215ECOSUN 400 K+ 400 1500×320×30 7,9 30 5401220Ceiling fi xing frame for ECOSUN 100 K+, 200 K+, 270 K+, 330 K+, 400 K+

TYPE [W] [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance [m] Quantity on pallet Cat. No.

ECOSUN 300 U 300

230 IP 44

592×592×30 5,0 from 2,5 m 40 5401037

ECOSUN 600 U 6001192×592×30

10,1 from 2,5 m 20 5401047

ECOSUN 700 U 700 10,5 from 2,7m 20 5401171

ECOSUN U – universal panel for dwelling and non-dwelling spaces, possibly mounted onto ceilings or into suspended ceilings. Class I.Basic colour: white (RAL 9016) Connection cable: 100 cm

TYPE [W] [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance [m] Quantity on pallet Cat. No.

ECOSUN 300 c 600/VT 300230 IP 20

574×574×35 4,6 2,5–3,0 40 5401065

ECOSUN 600 c 600/VT 600 574×1174×35 9,4 2,8–3,3 20 5401075

ECOSUN C – heating panels only for mounting into suspended ceilings. Class I.Basic colour: white (RAL 9016)

TYPE [W] [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance [m] Quantity on pallet Cat. No.

ECOSUN 700 IKP 700

230

IP 54 1192×592×30 9,3 2,5–3,0 20 5401176

ECOSUN 700 IN 700 IP 651192×592×30 9,5

2,8–3,3 20 5401181

ECOSUN 700 IN-2 700 IP 65 E Ex 2 3,0–3,5 20 5401186

Ceiling fi xing frame for type IKP, IN, IN-2

ECOSUN IKP, IN, IN-2 – panels for industrial and agricultural applications (i.e. in workshops, greenhouses, livestock facilities).Basic colour: brown (RAL 8017) Connection cable: 100 cm

ECOSUN G – a glass radiant panel derived from GR panels. The panel is supplemented with thermal insulation, with a frame from eloxed aluminium and versatile fi xtures which enable installation both on a wall (vertically) and on the ceiling (horizontally). This makes it a versatile product which combines the advantages of ECOSUN radiant panels and the design of GR glass panels. Protection class II; length of supply cables 1 m. Option of installing on a class C or D fl ammable base.

TYPE [W] [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance [m] Quantity on pallet Cat. No.

ECOSUN G 300 white 300

230 IP 20

600×600×50 7

vertical or horizontal position

40 5437110

ECOSUN G 600 white 600 1200×600×50 14 20 5437112

ECOSUN G 300 black 300 600×600×50 7 40 5437116

ECOSUN G 600 black 600 1200×600×50 14 20 5437118

ECOSUN G 300 mirror 300 600×600×50 8 40 5437122

ECOSUN G 600 mirror 600 1200×600×50 14,5 20 5437124

ECOSUN E – an alternative version of the ECOSUN G glass radiant panel. For this panel, the front glass has been substituted by a panel with a plastic powder coating; however, the panel has higher IP coverage and is suitable e.g. for health care applications. Protection class II; length of supply cables 1 m. Option of installing on a class C or D fl ammable base.

TYPE [W] [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance [m] Quantity on pallet Cat. No.

ECOSUN E 300 white 300

230 IP 44

600×600×50 5

vertical or horizontal position

40 5437140

ECOSUN E 600 white 600 1200×600×50 10,2 20 5437142

Page 6: En Catalogue

6

HIGH TEMPERATURE PANELS

HALOGEN HEATERSHalogen heaters – the high surface temperature of halogen tubes enables the use of the radiators in areas where normal radiant panels wouldn’t be effective – for example, in outdoor areas for the heating of terraces and balconies, or for the heating of large industrial halls with no heat cladding.

TYPE [W] [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance [m] Cat. No.

HWP 1500 1500

230

IP 55 480×120×120 1,7 2,2–3,0 m 8102010

HN 4500 4500

IP 21

590×430×140 6,5 3,0–4,5 m 8102035

HN 6000 6000 590×430×140 6,5 3,5–5,5 m 8102040

ECOSUN S / SB – for industrial halls, gyps, halls, workshops, wit coverage that corresponds to the given environment. Suitable for drying of buildings. Class I. Covering IP x4. Basic colour: white (RAL 9010). For spaces with higher humidity – agricultural structures, washing facilities, panels are produced in a corrosion-proof version SBs – stainless.

TYPE [W] [V] Weight [kg] Quantity on pallet Dimmensions [mm] Cat. No.

ECOSUN S 09 900230 8,7 58 1500×150×60

5401409

ECOSUN S 12 1200 5401412

ECOSUN S 18 1800

230 / 4002N

14 39 1500×250×605401418

ECOSUN S 24 2400 5401424

ECOSUN S 30 300018,5 26 1500×350×60

5401430

ECOSUN S 36 3600 5401436

TYPE [W] [V] Weight [kg] Quantity on pallet Dimmensions [mm] Cat. No.

ECOSUN SBs 09 900230 5,8 75 1500×130×50

5401709

ECOSUN SBs 12 1200 5401712

ECOSUN SBs 18 1800

230 / 4002N

9,9 45 1500×230×505401718

ECOSUN SBs 24 2400 5401724

ECOSUN SBs 30 300013,9 30 1500×330×50

5101730

ECOSUN SBs 36 3600 5401736

TYPE Cat. No.

Tiltable bracket for ECOSUN S 9–12 5401797

Tiltable bracket for ECOSUN S 18–36 5401798

TILTABLE BRACKET – a tiltable bracket enables the installation of ECOSUN S/SB panels at an angle, and thus the aiming of the heat fl ow at the required area. The bracket can be used for ceiling as well as wall installation; the package contains 1 pair of brackets (two pieces).

TYPE Cat. No.

Protective grille for ECOSUN S 9–12 5401790

Protective grille for ECOSUN S 18–24 5401792

Protective grille for ECOSUN S 30–36 5401794

PROTECTIVE GRILLE – the protective grille protects the lamellas of ECOSUN S/SB high-temperature panels against mechanical damage (for example, by a ball in a gym) and simultaneously prevents objects from coming into direct contact with the hot surface of the heating lamellas.

Page 7: En Catalogue

7

MR PANELS – marble radiant panels (thermo fuse), IP 44, class II; Connection cable for 300–1000:100 cm, 1200: 150 cm;Type of marble: Kavala, Volakas, Janina, Rosa, Veria Green; Needed clearance: lower edge 5 cm / top and side edge 15 cm / front side 50 cm

IP 44TYPE OUTPUT [W] Dimensions [mm] Weight [kg]

Quantity on pallet / in crate

Marble Cat. No.

MR300 300 500×500×30 20 10 / 22

Volakas

5438000

MR500 500 700×500×30 28 10 / 20 5438005

MR800 800 900×600×30 43 5 / 11 5438010

MR1000 1000 1100×600×30 53 5 / 11 5438015

MR1200 1200 1300×600×30 62 5 / 7 5438020

MR300 300 500×500×30 20 10 / 22

Kavala

5438200

MR500 500 700×500×30 28 10 / 20 5438205

MR800 800 900×600×30 43 5 / 11 5438210

MR1000 1000 1100×600×30 53 5 / 11 5438215

MR1200 1200 1300×600×30 62 5 / 7 5438220

MR300 300 500×500×30 20 10 / 22

Janina

5438050

MR500 500 700×500×30 28 10 / 20 5438055

MR800 800 900×600×30 43 5 / 11 5438060

MR1000 1000 1100×600×30 53 5 / 11 5438065

MR1200 1200 1300×600×30 62 5 / 7 5438070

MR300 300 500×500×30 20 10 / 22

Rosa

5438100

MR500 500 700×500×30 28 10 / 20 5438105

MR800 800 900×600×30 43 5 / 11 5438110

MR1000 1000 1100×600×30 53 5 / 11 5438115

MR1200 1200 1300×600×30 62 5 / 7 5438120

MR300 300 500×500×30 20 10 / 22

Veria Green

5438250

MR500 500 700×500×30 28 10 / 20 5438255

MR800 800 900×600×30 43 5 / 11 5438260

MR1000 1000 1100×600×30 53 5 / 11 5438265

MR1200 1200 1300×600×30 62 5 / 7 5438270

MR marble radiant panels are primarily intended for heating reception rooms, halls, bathrooms and others.MR panel has an extremely aesthetic appearance and the radi-ant heat from this natural material is very acceptable. The MR panel consists of a robust polished marble plate, a heating ele-ment, limiting thermostat , and a connection cable. This panel is intended to be installed as a fi xed installation on a wall with the connection cable connected to the installation box. These panels are manufactured in various power outputs and are available in 5 marble designs.As marble is a natural material there is the possibility of small colour and texture variances.

MR – marble radiant panels

RADIANT PANELS

Page 8: En Catalogue

8

GR PANELS – glass panels (thermo fuse), IP 44, class II; Connection cable: 100 cm; Panels are manufactured in 4 series with different outputs. GR panels you can choose from fi ve colours: mirror, white, black, red, yellow-green; Needed clearance: lower edge 5 cm / top and side edge 15 cm / front side 50 cm

TYPE Output [W] Dimensions [mm] Weight [kg]Quantity

on pallet / in crateGlass colour Cat. No.

GR 300 300 700×500×12 14 10 / 22 pcs

white, black, red, yellow-green

543760x

GR 500 500 900×600×12 21 5 / 12 pcs 543761x

GR 700 700 1100×600×12 26 5 / 12 pcs 543762x

GR 900 900 1200×800×12 38 5 / 8 pcs 543763x

GR 500 500 900×600×8 21 5 / 12 pcs

mirror

5437611

GR 900 900 1200×800×8 38 5 / 8 pcs 5437631

GR glass radiant panels feature an attractive and timeless design. Due to the aesthetic appearance these panels are primarily intend-ed for heating reception rooms, offi ces and others. Glass panels consist of a 12 mm toughened glass plate heating element, thermo fuse, and connection cable. They are designed to be mounted on a wall connecting the connection cable to the wiring box.

GR – glass radiant panels

GR panels

GR SET – panels with wireless regulationUse: These types are derived from standard GR panels but they are additionally fi tted with an integrated BPT-SP2 wireless receiver (see the chapter THERMOSTATS AND CONTROLS) and a supply lead fi tted with a plug. A wireless programmable thermostat is supplied with every panel as part of the package and so it is possible that, after unpacking the product, hanging it on the wall and connecting it to the socket, the panel can be operated immediately, without any assistance from a specialized installation company. The panels are intended mainly for supplementary installation, without the necessity of intervention into the existing electrical system. GR SET panels can be supplemented with chromium-coated supports (see page 9) and thus a very aesthetic and convenient portable heater can be created. Glass colours: white, black, yellow-green, red and mirror.

IP 44TYPE Output [W] Dimensions [mm] Weight [kg] Glass colour Cat. No.

GR Set 300 300 700×500×12 14,9

white, black, red, yellow-green

543770x

GR Set 500 500 900×600×12 21 543771x

GR Set 700 700 1100×600×12 28,4 543772x

GR Set 900 900 1200×800×12 38 543773x

GR Set 500 500 900×600×8 20mirror

5437711

GR Set 900 900 1200×800×8 37 5437731

Page 9: En Catalogue

9

NOTIFICATION

ECOSUN, MR and GR radiant panels are only equipped with a limiting thermostat – suitable regulation is essential for correct and economical operation; see the chapter THERMOSTATS AND CONTROLS. In the case of GR and GR SET glass panels, the limiting thermostat switches off the panels at an average temperature of 90 °C, and therefore the real thermal output of the panels is approximately 10 % lower than the wattage. For this reason and also for the improvement of the dynamics of the whole heating system, we recommend that the installed wattage is increased by 20 % in contrast with the result of the heat loss calculation. GR and GR SET panels can be supplemented with chromium-coated supports which enable the panel to be placed on the fl oor – e.g. in proximity to glass surfaces or to create a stylish portable heater.

SUPPORTS FOR GR PANELS – for applications where the GR panel cannot be hung on a wall (e.g. in the case of glass surfaces), a set of chromium plated supports can be used for the placement of the panels on the fl oor.

The GR panel is inserted into apertures in the supports and subsequently the supports are affi xed to the panels with the help of adjustment screws. The panel is stable on these supports; the bottom edge of the panel is 55 mm above the fl oor. For permanent instal-lations, we recommend that the supports are attached to the fl oor using screws – in the base there are two openings with a diameter of 6 mm for screws with countersunk heads. The supports are intended for use only with the GR type and are only for horizontal installation. In the case of vertical installation (particularly for GR 1000 panels), there is a signifi cantly higher risk that the user may accidentally knock the panel over. GR panels on supports must not be exposed to excessive pressure – there is a danger of tipping if it is placed freely, and if the supports are attached to the fl oor, there is a risk of damage to the glass in the places where supports are attached.

PRODUCT Cat. No.Supports for GR panels Contents of the set: chromium plated supports – 2 pcs (base diameter 130 mm), plastic covers for the brackets for the GR panel – 4 pcs, mains plug (to be installed on the supply lead if the panel is to be used as a mobile heater)

8000100 TYPE Description Weight [kg] Cat. No.Simple towel rail (width 500 mm) GR (SET) 300 0,9 5437810Simple towel rail (width 600 mm) GR (SET) 500 and 700 1,05 5437812Simple towel rail (width 800 mm) GR (SET) 900 1,2 5437818Double towel rail (width 500 mm) GR (SET) 300 1,8 5437820Double towel rail (width 600 mm) GR (SET) 500 and 700 2,1 5437822Double towel rail (width 800 mm) GR (SET) 900 2,4 5437824

The rail is intended only for panels installed vertically; however, the installation itself is very easy. The openings in the back part of the rail are simply placed onto the top two screws of the panel by which the heater will be attached to the wall. The panel is then placed into the prepared hanging brackets. After the attachment nuts have been tightened, the rail, which is placed between the back part of the panel and the hanging bracket, is attached fi rmly. The rail is in the shape of a rectangle with the dimensions 530×90 mm; the distance between the attachment openings is 260 mm.

STAINLESS STEEL TOWEL RAIL – for GR/GR SET 300, 500, 700 and 900 panelsThese Towel rail – designed as an accessory for GR and GR SET radiant glass panels in all colour versions. It is made from a 4×30 mm polished stainless steel sheet. After its installation, the standard panel is transformed into a smart bathroom heater with a rail on which a towel or bath towel can be hung.

Page 10: En Catalogue

10

IRC PANELS radiant heating for infrared cabins

The principle behind infrared cabins (infrared saunas)In infrared cabins (also called infrared saunas), so-called radiant heat is used – it works on a similar principle to ECOSUN heating panels. In this case, however, it is aimed at warming the muscle tissue of the user up to a depth of approximately 4 cm with the help of infrared radiation. Thanks to this deep warming of the organ-ism, intensive sweating takes places at a lower air temperature than in the case of classic steam saunas – during the whole of the user’s stay in the cabin, the air temperature ranges between 30 and approx. 55 °C.

Infrared cabins can be used over longer intervals, with the aim of freeing one’s body from harmful substances which are released when sweating, or in shorter intervals in which the aim is to warm up the muscle tissue before expected physical exercise – muscle stretching, body-building, running etc.

Advantages of infrared cabins with IRC panels

Infrared heating warms up the skin faster and the heat also penetrates deeper into the tissues than heat from hot steamThanks to the lower air temperatures involved, they are also suitable for patients with cardiovascular diseases or respiratory diseasesIn contrast with other types, they have considerably lower acquisition costs and minimum negative infl uences on the surrounding environment – humidityThe operation costs are lower by 1/3 to 1/2 in comparison with steam saunas (lower air temperature in the cabin; up to 80 % of energy is used for direct heating of the body)Large-surface IRC radiant panels heat evenly across their whole surface and for example in contrast with ceramic radiators, the performance of which is concentrated into a small surface with a high temperature, they heat the whole body signifi cantly better and more evenlyThe possibility of minimizing spatial requirements – a cabin can be installed in an area as small as 1 m2 – suitable also for smaller fl atsModular assembly without the necessity to use special tools in connection with the IRT regulator – the option of assembling the infrared cabin without expert aid

Page 11: En Catalogue

11

CONTROL UNIT – IRT 01 REGULATOR – The IRT regulator maintains a set temperature on the surface of radiant panels, as well as the required operating time of the heating and lighting of the infrared cabin. It contains a power unit (installed within a cavity under the bench) to which IRC panels are connected using plugs, and also a control unit, light and supply cable. Up to 6 IRC panels can be connected. All IRC panels are equipped with a special connector and the offered sizes can be combined as needed; however, the total wattage mustn’t exceed 3.4 kW and one (only one) of the panels used must have an integrated temperature sensor. The power unit is connected to a 230 V socket, protected with a 30 mA residual current device.

IP 44IP 44 DESCRIPTION Cat. No.

IRT 01 REGULATORTemperature setting 20–80 °C; time setting 1 to 99 minutes; switch

Set contents: control unit including a connection cable; power unit with connectors; 3 m power cable with plug (230 V / 16 A); 3 m connection cable for lighting (light is not included in the set); instructions; screws – 8 pcs.

4200040

Set selectionAccording to the size of the infrared cabin you wish to install, choose and combine the offered panel sizes in such a way that they best cover the space within the infra-red cabin – the lower and upper halves of the body. It is ideal if the panels surround the user on at least three sides.There can be a maximum of six panels for every control unit, from which one (but only one) must be equipped with an integrated temperature probe. The maximum wattage of all the panels attached to one control unit can be up to 3.4 kW. An IRT-01 regulator is necessary to control the panels. The regulator comes with the set, which includes a control panel and power unit. The control panel should be installed inside the infrared cabin within reach of the user. The power unit is installed in a cavity under the bench and should not be easy to access. The connecting leads for the IRC panels are, after installation on the wall, connected to the power unit with the aid of connectors – the connectors from the panels, lighting, control units and connecting leads have different dimensions, so it isn’t possible to confuse them and connection can be carried out by a non-expert user.If lighting is required it is also possible to connect a light to the power unit; a connection cable comes as part of the set. It is necessary to equip panels with a suitable protective cover, allowing the correct operation of the panel. We recommend using the wooden covering frames that are offered, as they are constructed size-wise to exactly fi t the dimensions of the IRC panelsWooden frames not only fulfi l a protective function, but also attach panels to walls – the panels alone are not fi tted with any mounting apertures or brackets.

IRC RADIANT PANELS – FENIX has manufactured and supplied IRC panels for foreign producers of infrared cabins (Austria, Germany) since 2004. Now it is offering these panels on the Czech market together with a control unit – IRT regulator – and this also as a DIY kit.

IP 44 PRODUCT Output [W] Voltage [V] Weight [kg] Dimensions [mm] Cat. No.

IRC Panel 1130x360/200 200

230

875x360 5401805IRC Panel 1130x360/260 260 5,9 1130×360 5401810IRC Panel 1330x360/310 310 1330x360 5401811IRC Panel 650x780/330 330 650x780 5401813IRC Panel 1130x780/575 575 11,5 1130×780 5401812IRC Panel 1130x780/575 S (with a probe) 575 11,5 1130×780 5401814IRC Panel 1330x780/680 S (with a probe) 680 1330×780 5401815

Page 12: En Catalogue

12

ECOFLOOR®

underfl oor heating systems

Cable ASL1Pheating mats LD

Cable ADSV-Theating mats LDTS, LSDTS

Cable ADSVheating circuits ADSV

Cable ADSV+heating circuits ADSV+

Cable ADSAultrathin mats CM

Cable PVheating circuits PV (earlier P1P)

Overview of ECOFLOOR heating cables and recommended usage

ECOFLOOR electric fl oor heating systems ensure ideal heat distri-bution and, by decreasing undesirable air circulation, reduce dust levels. These systems offer great comfort, economic and reliable operation, and long lifetime. They preserve free fl oor space by eliminating the need for various heating elements, radiators and heat distribution systems. The principal advantage of electric fl oor heating is easy and separate temperature control in individual rooms. Once installed, it is completely maintenance free.We provide 10 year warranty for underfl oor heating cables and mats and 2 year warranty for cables used for outdoor application (gutter, eaves, pipes).

*) for a short term (installation under asphalt)

Type

Watta

ge [W

/m]

Numb

er of

heati

ng co

res

Protec

tive s

creen

Protec

tion a

gains

t UV r

adiat

ion

Therm

al en

duran

ce of

the ja

cket

Supp

lied a

s circ

uit

Supp

lied a

s mat

Floor heatingAnti-freeze

protection of

Direct

-heati

ng

Semi

-stora

ge

Storag

e

Surfa

ces

Roofs

Pipes

ASL1P10

1�

70 °C� � �

15 � � � �

18 � � � �

ADSV10

2�

70 °C� � �

15 � � � �

18 � � � �

ADSV-T 12 2 � 70 °C � �

ADSV+10

2� �

80 °C� �

18 � � � �

20 � � � �

ADSA 12 2 � 70 °C � �

ADPSV10

2� �

80 °C� �

18 � � � � � �

20 � � � �

PV (P1P)10

1 70 °C� �

15 � �

PSV10

1�

70 °C� � �

15 � � � �

MAPSV20

1� �

80 °C� � � � �

25 � � � �

30 � � � � �

MADPSP

15

2

� �

90 °C240 °C*

� � � � � �

20 � � � � � � � �

25 � � � � � � �

30 � � � � �

PDSP 28 2 � �90 °C

200 °C* � �

PFP 12 2 � � 70 °C � �

PDS1P 40 2 � 70 °C � �

Page 13: En Catalogue

13

Overview of ECOFLOOR heating mats and recommended usage

Overview of special ECOFLOOR heating cables and recommended usage

Cable PSVheating circuits PSV

Cable ADPSVheating circuits ADPSV

Cable MAPSVheating circuits MAPSV, heating mats MST

Cable MADPSPheating circuits MADPSP, heating mats MDT

Cable PDSPheating circuits PDSP

Cable PDS1Pfor curing concrete

Type

Watta

ge [W

/m]

Numb

er of

heati

ng co

res

Protec

tive s

creen

Protec

tion a

gains

t UV r

adiat

ion

Therm

al en

duran

ce of

the ja

cket

Supp

lied a

s circ

uit

Supp

lied a

s mat

Floor heatingAnti-freeze

protection of

Direct

-heati

ng

Semi

-stora

ge

Storag

e

Surfa

ces

Roofs

Pipes

ELSR-M10

2� �

65 °C� �

15 � � � �

ELSR-N20

2� �

80 °C� � �

30 � � � � �

PCC 30 1 � −40…60 °C �

PC25

2 −50…60 °C�

50 �

PC-S20

2�

−50…60 °C�

25 � �

PCC cableheating circuits for anti-freeze protection –heating of the insulating door seals of freezers

Cable ELSR-Mself-regulating cable for anti-freeze protection and technological heating (10 and 15 W/m)

PC cableheating cable with a constant linear wattage for anti-freeze protection and process heating

Cable ELSR-Nself-regulating cable for anti-freeze protection and technological heating (20 and 30 W/m EExII)

PC-S cablearmoured heating cable (metal braiding)with a constant linear wattage for anti-freeze protection and process heating

Type

Watta

ge [W

/m]

Numb

er of

heati

ng co

res

Protec

tive s

creen

Protec

tion a

gains

t UV r

adiat

ion

Therm

al en

duran

ce of

the ja

cket Floor heating

Heati

ng of

outdo

or are

as

Type o

f hea

ting c

able

Direct

-heati

ng

Semi

-stora

ge

Storag

e

CM 150 2 � 90 °C � ADSA

LDTS80

2�

70 °C� �

ADSV-T100 � � �

160 � � �

LD 160 1 � 70 °C � � ASL1P

LSDTS100

2�

70 °C�

ADSV-T160 � �

LPSV 100 1 � 80 °C � PSVMST 300 1 � � 80 °C � MAPSVMDT 300 2 � � 90 °C � � MADPSP

Cable composition markings

1 Resistance (heating) wire

M multi-resistance – stranded resistance wire (to be used for higher outputs);

No letter is used for a non-stranded (simple) resistance wire

2 Core insulation

A FEP (fl uoropolymer)

P XLPE (cross-linked polyethylene)

3 Number of heating cores

D double-core cable;No letter is used for a single-core cable

4 Plastic insulation (for outdoor applications, higher mechanical ruggedness of cable)

P XLPE (cross-linked polyethylene);No letter is used for a cable without the second plastic insulation

5 Protection screen (for wet areas)

S full screen protection (tinned copper wires and aluminium tape)

SL linear screen protectionNo letter is used for a cable without screen protection

6 Jacket

P XLPE (cross-linked polyethylene)

1P PP-LDPE (mixed polypropylene & low density PE)

V PVC (polyvinyl chloride)

1 2 3 4 5 6

M A D P S P

Linear input of cable [W/m]

Total input of circuit [W]

2 0 2 4 0

Page 14: En Catalogue

14

DIRECT HEATING SYSTEM1 wear layer (ceramic fl oor tiling)2 fl exible bonding cement3 ECOFLOOR® heating mat4 fl oor (limitation) probe in a protective tube (so-called goose neck)5 load-bearing concrete fl oating board6 steel reinforcement (so-called Kari mesh)7 thermal insulation8 base (concrete board)

DIRECT HEATING SYSTEMSECOFLOOR CABLES AND MATS

ECOFLOOR heating systems are available in two basic variants – heating cable circuits and heating mats. In fact the two systems do not differ from one another very much. In both cases, the heating system consists of a heating cable, either separate or fi xed to a supporting fi breglass cloth (heating mat). This modern fl oor heating system permits easy and effective regulation. The heating cable circuit or mats are placed directly beneath tiles in a thin layer of permanently fl exible cement so the tiled surface heats up relatively quickly (circa 20 min). Temperature control is sensitive and quick to react. Heating cable circuits or mats are suitable for renovated fl oors where the fi nal fl oor height is not a constraint.

DIRECT HEATING SYSTEM—RECONSTRUCTION1 wear layer (ceramic fl oor tiling)2 fl exible bonding cement3 heating mat (cable) ECOFLOOR®

4 fl oor (limitation) probe in a protective tube (so-called goose neck)5 F-BOARD supplementary thermal insulation

(shortens the warming time) (see page 25)6 fl exible bonding cement7 original fl oor (old fl oor tiling, concrete)

Page 15: En Catalogue

15

LDTS / LSDTS heating matLDTS / LSDTS packing

ECOFLOOR Installation – Heating Mat1) Unroll the heating mat according to the layout drawing.2) If you need to leave a space under fi xed furniture, cut out the necessary part of the cloth and span the space with the cable (see fi g. 2).3) Level the layer of fl exible cement with a smooth trowel.4) Lay tiling on small areas (up to 4 m2) immediately, and on larger areas after 24 hours.

ECOFLOOR HEATING MATS

LDTS 80 W/m2

OUTPUT [W]

Type80 W/m2

Surface [m2]

Length [m]

Cat. No.LDTS

60 80/0.8 0,8 1,5 5531502105 80/1.3 1,3 2,6 5531504180 80/2.3 2,3 4,5 5531506220 80/2.8 2,8 5,5 5531508290 80/3.6 3,6 7,2 5531510410 80/5.1 5,1 10,2 5531512460 80/5.8 5,8 11,5 5531514560 80/7.0 7,0 14,0 5531516820 80/10.3 10,3 20,5 5531518

1000 80/12.5 12,5 25,0 55315201200 80/15.0 15,0 30,0 55315221800 80/22.5 22,5 45,0 5531524

LDTS 160 W/m2

OUTPUT [W]

Type160 W/m2

Surface [m2]

Length [m]

Cat. No.LDTS

80 160-0,5 0,5 1,0 5540001160 160-1 1,0 2,0 5540002240 160-1,5 1,5 3,0 5540003320 160-2 2,0 4,0 5540004400 160-2,5 2,5 5,0 5540005480 160-3 3,0 6,0 5540006560 160-3,5 3,5 7,0 5540007640 160-4 4,0 8,0 5540008800 160-5 5,0 10,0 5540009960 160-6 6,0 12,0 5540010

OUTPUT [W]

Type160 W/m2

Surface [m2]

Length [m]

Cat. No.LDTS

Cat. No.LSDTS

70 160/0.5 0,5 0,9 5530200 5531005130 160/0.8 0,8 1,6 5530205 5531010210 160/1.3 1,3 2,6 5530210 5531015260 160/1.6 1,6 3,2 5530220 5531020340 160/2.1 2,1 4,2 5530230 5531025410 160/2.6 2,6 5,2 5530240 5531030500 160/3.0 3,0 6,0 5530250 5531035560 160/3.4 3,4 6,7 5530255 5531040670 160/4.2 4,2 8,3 5530260 5531045810 160/5.1 5,1 10,2 5530270 5531050

1000 160/6.1 6,1 12,3 5530280 55310551210 160/7.6 7,6 15,1 5530290 55310601400 160/8.8 8,8 17,6 5530190 55310801800 160/11.0 11,0 22,0 5530192 55310852150 160/13.3 13,3 26,6 5530194 55310902600 160/16.3 16,3 32,5 5530196 5531095

LDTS / LSDTS 160 W/m2

LDTS or LSDTS (self-adhesive) heating mat, twin conductor cable with a full protection screen, width 50 cm, cold lead 1×3 m. LDTS mats are provided with self-adhesive tape for affi xing to the fl oor. LSDTS mats have a self-adhering mesh on their entire back surfaces.

OUTPUT [W]

Type100 W/m2

Surface [m2]

Length [m]

Cat. No.LDTS

Cat. No.LSDTS

60 100/0.6 0,6 1,2 5530401 5531105 105 100/1.0 1,0 2,1 5530403 5531110 180 100/1.8 1,8 3,6 5530405 5531115 220 100/2.2 2,2 4,4 5530410 5531120 290 100/2.9 2,9 5,8 5530415 5531125 410 100/4.1 4,1 8,2 5530420 5531130 460 100/4.7 4,7 9,4 5530425 5531135 560 100/5.6 5,6 11,2 5530430 5531140 820 100/8.2 8,2 16,5 5530440 5531145

1000 100/10.2 10,2 20,3 5530450 5531150 1200 100/11.8 11,8 23,7 5530460 5531155 1800 100/17.9 17,9 35,8 5530470 5531160

LDTS / LSDTS 100 W/m2

LD matPacking in PE foil.LD matPacking in PE foil.

LD heating mat, single conductor cable with a full protection screen, width up to 3 m2 – 30 cm, over 3 m2 – 50 cm, cold lead 2×5 m

OUTPUT [W]

Type LD160 W/m2

Surface [m2]

Width [m]

Length [m] Cat. No.

100 160/0.6 0,6 0,3 2,0 5530005150 160/0.9 0,9 0,3 3,0 5530007180 160/1.1 1,1 0,3 3,6 5530010300 160/1.8 1,8 0,3 6,1 5530020360 160/2.3 2,3 0,3 7,6 5530030500 160/3.0 3,0 0,3 10,0 5530040700 160/4.3 4,3 0,5 8,6 5530050850 160/5.3 5,3 0,5 10,6 5530060950 160/5.9 5,9 0,5 11,8 55300701150 160/7.2 7,2 0,5 14,4 55300801700 160/10.7 10,7 0,5 21,4 55300902000 160/12.4 12,4 0,5 24,9 55301002500 160/15.7 15,7 0,5 31,3 55301103000 160/18.8 18,8 0,5 37,6 5530120

LD 160 W/m2

ULTRA THIN CM MATS – a very thin two conductor cable with a protective screen – suitable for damp areas (bathrooms, laundry rooms) as well as for standard rooms – ideal for placement into adhesive sealing cement directly under floor tiling; Ø of cable 2.4–2.7 mm, cold lead – 1×2.5 m.

CM 150 W/m2

OUTPUT [W] Type Surface

[m2]Length

[m] Cat. No.

150 CM150/1 1,0 2,0 5540103225 CM150/1,5 1,5 3,0 5540105300 CM150/2 2,0 4,0 5540107375 CM150/2,5 2,5 5,0 5540109450 CM150/3 3,0 6,0 5540111600 CM150/4 4,0 8,0 5540113750 CM150/5 5,0 10,0 5540115

Page 16: En Catalogue

16

ADSV heating cable, a twin conductor cable with a full protection screen suitable for wet areas. For direct fl oor heating or fl oor renovating (installation under tiles). Cable diameter 3.6–4.6 mm.Cold tail 1×3 m.

ECOFLOOR HEATING CABLE CIRCUITS

OUTPUT [W]

Type ADSV10 W/m

LENGTH [m] Cat. No.

65 10065 6,6 2232100120 10120 11,4 2232105200 10200 18,9 2232110250 10250 23,6 2232115320 10320 31,6 2232120400 10400 36,9 2232125450 10450 45,9 2232130520 10520 49,6 2232135600 10600 63,9 2232140750 10750 75,8 2232145950 10950 87,0 22321501100 101100 114,5 22321551300 101300 131,3 22321601700 101700 158,5 22321652000 102000 194,5 2232170

OUTPUT [W]

Type ADSV15 W/m

LENGTH [m] Cat. No.

80 15080 5,4 2242405140 15140 9,8 2242407240 15240 15,7 2242410300 15300 19,7 2242415400 15400 25,3 2242420470 15470 31,4 2242425550 15550 37,4 2242430630 15630 41 2242435750 15750 51,1 2242440950 15950 59,9 22424451100 151100 75,1 22424501350 151350 93,3 22424551600 151600 106,7 22424602400 152400 162,1 2242465

OUTPUT [W]

Type ADSV18 W/m

LENGTH [m] Cat. No.

160 18160 8,50 2243120260 18260 14,50 2243125320 18320 18,50 2243130420 18420 24,00 2243135520 18520 28,40 2243140600 18600 34,4 2243145680 18680 37,9 2243150830 18830 46,1 2243155

1000 181000 57,5 22431601200 181200 68,9 22431651500 181500 83,2 22431701700 181700 100,4 22431752200 182200 122,7 22431802600 182600 149,6 2243185

TYPE(Ohm/m) Cat. No.

122,5 200151038,72 200151514,020 20015208,960 20015255,232 20015303,584 20015352,568 20015402,050 20015451,382 20015500,926 20015550,638 20015600,424 20015650,310 20015700,196 20015750,136 2001580

Cables on drums Heating circuits

m.

OUTPUT [W]

Type ASL1P10 W/m

LENGTH [m] Cat. No.

160 10160 17,0 2200160280 10280 27,0 2200280350 10350 33,7 2200350450 10450 45,0 2200450640 10640 64,0 2200640800 10800 77,2 2200800960 10960 80,0 22009601100 101100 103,9 22011001600 101600 156,0 22016001900 101900 179,6 22019003000 103000 259,3 2203000

OUTPUT [W]

Type ASL1P15 W/m

LENGTH [m] Cat. No.

200 15200 13,7 2201000340 15340 22,2 2201005420 15420 28,1 2201010550 15550 36,8 2201015800 15800 51,5 2201020960 15960 64,3 2201025

1070 151070 71,5 22010301300 151300 87,9 22010351900 151900 131,3 22010402200 152200 155,1 22010453400 153400 228,8 2201055

OUTPUT [W]

Type ASL1P18 W/m

LENGTH [m] Cat. No.

210 18210 11,9 2201060350 18350 19,7 2201062450 18450 24 2201064570 18570 32,5 2201066820 18820 46 2201068

1000 181000 56,5 22010701100 181100 63,7 22010721400 181400 74,7 22010742000 182000 114,2 22010762400 182400 130,1 22010783000 183000 164,6 22010803500 183500 203,4 2201082

Cables on drumsTYPE

(Ohm/m) Cat. No.

61,25 200517827,13 200517919,36 20051807,010 20051814,480 20051822,616 20051831,284 20051850,857 20051870,691 20051880,463 20051900,212 20051920,155 20051930,068 2005195

Heating circuits

ECOFLOOR Installation – Heating Cable Circuit1) Create loops of the heating cable across the entire base (a spacing guide may be used, as shown).2) Fix the cable to the base using the self-adhesive tape or GRUFAST fastening strips.3) Level the layer of fl exible cement with a smooth trowel.4) Lay tiling on small areas (up to 4 m2) immediately, and on larger areas after 24 hours.

Cable on drum Cable circuit on carton reel.Standard packing. Packing in carton

box available

ASL1P heating cable, a single-conductor cable with a full protection screen suitable for wet areas. For direct fl oor heating (installation under tiles).

Cold lead 2×5 m. Cable diameter 2.9–3.6 mm. Packing in PE foil.

Page 17: En Catalogue

17

OUTPUT [W]

Type CK(10 W/m)

AREA [m2]160 W/m2

AREA [m2]130 W/m2

AREA [m2]100 W/m2

LENGTH [m] Cat. No.

65 10065 0,4 0,5 0,65 6,6 2360094120 10120 0,75 0,95 1,2 11,4 2360097200 10200 1,25 1,6 2,0 18,9 2360100250 10250 1,6 2,0 2,5 23,6 2360102320 10320 2,0 2,6 3,2 31,6 2360104400 10400 2,5 3,2 4,0 36,9 2360106450 10450 2,8 3,6 4,5 45,9 2360108520 10520 3,25 4,0 5,2 49,6 2360109600 10600 3,75 4,8 6,0 63,9 2360110750 10750 4,7 6,1 7,5 75,8 2360112950 10950 5,9 7,7 9,5 87,0 23601141100 101100 6,9 8,9 11,0 114,5 23601161300 101300 8,1 10,5 13,0 131,3 23601181700 101700 10,6 13,1 17,0 158,8 23601192000 102000 12,5 16,2 20,0 194,5 2360120

Kits for do-it-yourself installation have been designed for those users who do not want a complete electrical heating system but a comfortable, warm fl oor in a specifi c area (e.g. bathroom or kitchen). The kits include everything needed to install the fl oor heating system and are very reasonably priced. They are sold in two variants:

ECOFLOOR ComfortMat

KITS FOR DO-IT-YOURSELF INSTALLATION

OUTPUT [W]

Type CM160 W/m2

AREA[m2]

LENGTH [m] Cat. No.

70 12070-165 0,5 0,9 5590094130 12130-165 0,8 1,6 5590097210 12210-165 1,3 2,6 5590100260 12260-165 1,6 3,2 5590105340 12340-165 2,1 4,2 5590110410 12410-165 2,6 5,2 5590115500 12500-165 3,0 6,1 5590120560 12560-165 3,4 6,7 5590122670 12670-165 4,2 8,3 5590125810 12810-165 5,1 10,2 5590130

1000 121000-165 6,1 12,3 55901351210 121210-165 7,6 15,1 55901401400 121400-165 8,8 17,6 5590145

OUTPUT [W]

Type CM100 W/m2

AREA[m2]

LENGTH [m] Cat. No.

180 8180-105 1,9 3,6 5590148220 8220-105 2,2 4,4 5590150290 8290-105 2,9 5,8 5590152410 8410-105 4,1 8,2 5590155460 8460-105 4,7 9,4 5590157560 8560-105 5,6 11,2 5590160820 8820-105 8,2 16,5 5590165

ECOFLOOR CableKit

Width of the heating mat is 50 cm

Comfort mat includes heating mat LDTS digital thermostat Aube TH 132 AF with fl oor sensor protection tube for fl oor sensor installation manual

Cable kit includes heating cable ADSV on carton reel thermostat Fenix Therm 100 with fl oor sensor protection tube for fl oor sensor adhesive fi xing tape template to plane cable runs for 100 W/m2, 130 W/m2 and 160 W/m2

installation manual

It is recommended that you install F-Board insulated tile backer board before laying CK or CM. This will ensure quicker warm up times and reduce running costs (see page 25).

Page 18: En Catalogue

18

STORAGE ECOFLOOR HEATING1 wear layer (fl oor tiles, carpet, PVC, laminate)2 fl oor (limitation) probe in a protective tube (so-called goose neck)3 concrete storage layer4 ECOFLOOR® heating mat (cable)5 concrete storage layer6 steel reinforcement (so-called Kari mesh)7 thermal insulation8 base (concrete board)

SEMI-STORAGE SYSTEM1 wear layer (fl oor tiling, carpet, PVC, laminate)2 fl oor (limitation) probe in a protective tube (so-called goose neck)3 load-bearing concrete fl oating board4 steel reinforcement (so-called Kari mesh)5 ECOFLOOR® heating mat (cable)6 thermal insulation7 base (concrete board)

SEMI-STORAGE AND STORAGE HEATINGECOFLOOR CABLES AND MATS

Heating cables or mats in semi-storage systems are placed in a layer of concrete 4–5 cm thick. The mat’s recommended output wattage is 160 W/m2. Heat is accumulated for 16 hours a day at a time when electricity costs are lowest. The accumulated heat is radiated from the fl oor surface not only during the process, but also for a further 8 hours. One effi cient solution is to divide the total desired heating system 70/30 between the fl oor heating and another source, such as a convection heater or an ECOSUN radiant panel.

Storage fl oor heating is a system that takes advantage of cheaper electricity tariffs – usually at night. During this time, heat is accumulated into the mass of the fl oor using ECOFLOOR electrical heating cables or mats. Throughout the rest of the day, the heat is gradually released from the fl oor to the room. In storage systems, heating mats or cables are placed in a layer of concrete 10 to 14 cm thick. The accumulated—stored—heat is then released during the day into the area to be heated. We recommend an output wattage of 250 to 300 W/m2 for ECOFLOOR mats used in this type of system. Eight hours of low-tariff electricity should be used to accumulate the heat.

ncrete board)

Page 19: En Catalogue

19

PV cable circuita single conductor cable with 2×5 m cold leads.Packing in PE foil.

OUTPUT [W]

Type PV 15 W/m

LENGTH [m] Cat. No.

200 15200 13,7 2318190340 15340 22 2318200420 15420 28 2318210550 15550 37 2318220660 15660 45 2318225800 15800 52 2318230880 15880 59 2318235960 15960 64 2318240

1070 151070 72 23182501210 151210 81 23182551300 151300 84 23182601580 151580 105 23182651900 151900 129 23182702200 152200 150 23182802800 152800 189 23182903400 153400 228 2318300

OUTPUT [W]

Type PV 10 W/m

LENGTH [m] Cat. No.

170 10170 16,1 2318000280 10280 28 1218010350 10350 34 2318020450 10450 46 2318030550 10550 53,7 2318035640 10640 64,4 2318040720 10720 71,7 2318045800 10800 79,1 2318050870 10870 88 2318055960 10960 100 23180601100 101100 106,8 23180651280 101280 129,6 23180701600 101600 157,9 23180801900 101900 189,6 23180902500 102500 234,7 23181003000 103000 277,8 2318110

PV heating cable, a single-conductor cable without a protection screen for storage and semi-storage heating. Cold lead 2×5 m. Cable diameter 3.9–4.4 mm.

TYPE(Ohm/m) Cat. No.

19,36 20000997,010 20001004,480 20001012,616 20001021,792 20001031,284 20001041,025 20001050,857 20001060,691 20001070,540 20001080,463 20001090,319 20001100,212 20001110,155 20001120,098 20001130,068 2000114

Cables on drums Heating circuits

PSV cable circuita single-conductor cable with 2×5 m cold leads.Packing in PE foil.

OUTPUT [W]

Type PSV 15 W/m

LENGTH [m] Cat. No.

200 15200 13,7 2320110340 15340 22,2 2320115420 15420 28,1 2320120550 15550 36,7 2320125660 15660 44,7 2320130800 15800 52,3 2320135880 15880 58,6 2320140960 15960 64,1 2320145

1070 151070 71,5 23201501210 151210 81,0 23201551300 151300 84,1 23201601580 151580 104,6 23201651900 151900 128,6 23201702200 152200 150,3 23201752800 152800 189,4 23201803400 153400 227,5 2320185

OUTPUT [W]

Type PSV 10 W/m

LENGTH [m] Cat. No.

170 10170 16,1 2320020280 10280 28,0 2320025350 10350 34,0 2320030450 10450 46,0 2320035550 10550 53,7 2320040640 10640 64,4 2320045720 10720 71,7 2320050800 10800 79,1 2320055870 10870 88,0 2320060960 10960 100,0 23200651100 101100 106,8 23200701280 101280 129,6 23200751600 101600 157,9 23200801900 101900 189,6 23200852500 102500 234,7 23200903000 103000 277,8 2320095

PSV heating cable, a single-conductor cable with a full protection screen for storage and semi-storage heating.

Cold lead 2×5 m. Cable diameter 4.5–5.1 mm.

TYPE(Ohm/m) Cat. No.

19,36 20012107,01 20012154,48 20012202,616 20012251,792 20012301,284 20012351,025 20012400,857 20012450,691 20012500,54 2001255

0,463 20012600,319 20012650,212 20012700,155 20012750,098 20012800,068 2001285

Cables on drums Heating circuits

OUTPUT [W]

Type ADPSV 18 W/m

LENGTH [m] Cat. No.

160 18160 8,5 2249960260 18260 14,5 2249963320 18320 18,5 2249966420 18420 24,0 2249969520 18520 28,4 2249972600 18600 34,4 2249975740 18740 41,8 2249976830 18830 46,1 2249978

1000 181000 57,5 22499811200 181200 68,9 22499841500 181500 83,2 22499871700 181700 100,4 22499902200 182200 122,7 22499922600 182600 149,6 2249993

ADPSV heating cable, a twin conductor cable with a full pro-tection screen is suitable for semi-storage and storage floor heating in living areas. Class M2. Cold lead 1×5 m. Ø 5.0–5.9 mm.

LPSV heating mat, single conductor cable with a full protec-tion screen, width 50 cm, cold lead 2×5 m. Packed on a cardboard tube and sealed in PE foil.

ADPSV cable circuita twin conductor cable

ADPSV packing

OUTPUT [W]

Type LPSV100 W/m2

Surface [m2]

Length [m] Cat. No.

180 LPSV 1,8 1,8 3,6 5520352300 LPSV 3 3,0 6,0 5520354370 LPSV 3, 3,7 7,4 5520356480 LPSV 3,7 4,8 9,6 5520358580 LPSV 5,8 5,8 11,6 5520360700 LPSV 7 7,0 14,0 5520362770 LPSV 7,7 7,7 15,4 5520364850 LPSV 8,5 8,5 17,0 5520366940 LPSV 9,4 9,4 18,8 5520368

1050 LPSV 10,5 10,5 21,0 55203701150 LPSV11,5 11,5 23,0 55203721400 LPSV 14 14,0 28,0 55203741700 LPSV 17 17,0 34,0 55203762000 LPSV 20 20,0 40,0 55203782500 LPSV 25 25,0 50,0 5520380

Page 20: En Catalogue

20

OUTDOOR APPLICATIONS

Ice and snow melting Installing electric heating cables in outdoor areas, together with a thermostat, prevents both ice formation and snow accumulation. Once installed, the system works entirely automatically and is only operational when it is snowing or if ice is forming on roads and walkways.

De-icing gutters and eaves troughsIn all parts of Europe other than in the south, winter brings a heavy load to many buildings as ice builds up in the gutters and eaves troughs. Installing an ECOFLOOR electric heating cable (with a protective screen) into gutters and eaves troughs is a good solution for such problems. The cables are installed using special plastic clips placed inside gutters and eaves troughs. We recommend a linear wattage of 20 W/m for the de-icing cables.

Frost protection of pipesMany homeowners and other users of piping have many troubles in the winter due to freezing pipes. This especially applies to pipes for water piping, but other liquids used in industrial technologies can also freeze or solidify. During long spells of below-freezing temperatures, even very well-insulated piping can freeze. Supplementary heating is a reliable preventive solution.

Page 21: En Catalogue

21

MAPSV heating cable, a single-conductor cable with a full protec-tion screen and protection against UV radiation. Suitable for heating outdoor surfaces. Cold lead 2×5 m. Ø 5.0–5.5 mm.

MAPSV cables 400 VOUTPUT

[W]Type MAPSV

20 W/m – 400 VLENGTH

[m] Cat. No.

600 20600 29,6 2322650700 20700 35,2 2322652

1000 201000 50,0 23226541550 201550 76,5 23226561800 201800 88,9 23226582300 202300 115,9 23226603000 203000 148,1 23226623500 203500 182,9 23226644200 204200 208,2 23226664600 204600 224,4 23226685800 205800 281,5 23226707000 207000 336,1 23226729000 209000 444,4 2322674

OUTPUT [W]

Type MAPSV 30 W/m – 400 V

LENGTH [m] Cat. No.

730 30730 24,4 2322700850 30850 29,0 2322702

1230 301230 40,7 23227041900 301900 62,4 23227062200 302200 72,7 23227082800 302800 95,2 23227103700 303700 120,1 23227124400 304400 145,5 23227145100 305100 171,4 23227165600 305600 184,3 23227187000 307000 233,2 23227208500 308500 276,8 232272211000 3011000 363,6 2322724

OUTPUT [W]

Type MAPSV20 W/m

LENGTH [m] Cat. No.

340 20340 17,3 2322500400 20400 20,3 2322502570 20570 29,0 2322504880 20880 44,5 2322506

1030 201030 51,4 23225081350 201350 65,3 23225101750 201750 84,0 23225122100 202100 100,8 23225142400 202400 120,4 23225162600 202600 131,3 23225183300 203300 163,6 23225204000 204000 194,5 23225225100 205100 259,3 2322524

OUTPUT [W]

Type MAPSV 30 W/m

LENGTH [m] Cat. No.

420 30420 14,0 2322600500 30500 16,3 2322602700 30700 23,6 23226041100 301100 35,6 23226061250 301250 42,3 23226081600 301600 55,1 23226102100 302100 70,0 23226122500 302500 84,6 23226142950 302950 98,0 23226163200 303200 106,7 23226184000 304000 134,9 23226204800 304800 162,1 23226226300 306300 209,9 2322624

OUTPUT [W]

Type MAPSV 25 W/m

LENGTH [m] Cat. No.

380 25380 15,5 2322550450 25450 18,1 2322552640 25640 25,8 2322554990 25990 40,0 23225561150 251150 46,0 23225581480 251480 59,6 23225601900 251900 77,3 23225622300 252300 92,0 23225642700 252700 107,1 23225662900 252900 117,1 23225683700 253700 145,9 23225704400 254400 176,8 23225725700 255700 232,0 2322574

TYPE(Ohm/m) Cat. No.

9,00 20008506,50 20008523,20 20008541,35 20008561,00 20008580,60 20008600,36 20008620,25 20008640,18 20008660,16 20008680,10 20008700,07 20008720,04 2000874

Cables on drums Heating circuits

MST mats, 230 V, width 0,5 m

Mats MST available also in 1m width. For easy installation the heating mat MST is provided with 1×5 m cold lead and with other cold lead 1×5 m + lenght of the mat. Cables and mats are packing in PE foil.

OUTPUT [W]

Type MST 300 W/m2

AREA [m2]

LENGTH [m] Cat. No.

450 23MST 300/1,5-0,5 1,5 3,0 5501100600 23MST 300/2-0,5 2,0 4,0 5501105900 23MST 300/3-0,5 3,0 6,0 5501110

1200 23MST 300/4-0,5 4,0 8,0 55011151500 23MST 300/5-0,5 5,0 10,0 55011201800 23MST 300/6-0,5 6,0 12,0 55011252100 23MST 300/7-0,5 7,0 14,0 55011302400 23MST 300/8-0,5 8,0 16,0 55011322700 23MST 300/9-0,5 9,0 18,0 55011353000 23MST 300/10-0,5 10,0 20,0 55011403600 23MST 300/12-0,5 12,0 24,0 55011454500 23MST 300/15-0,5 15,0 30,0 55011506000 23MST 300/20-0,5 20,0 40,0 5501155

MST mats, 400 V, width 0,5 mOUTPUT

[W]Type MST300 W/m2

AREA [m2]

LENGTH [m] Cat. No.

900 40MST 300/3-0,5 3,0 6,0 55013001200 40MST 300/4-0,5 4,0 8,0 55013051800 40MST 300/6-0,5 6,0 12,0 55013102100 40MST 300/7-0,5 7,0 14,0 55013152700 40MST 300/9-0,5 9,0 18,0 55013203600 40MST 300/12-0,5 12,0 24,0 55013254200 40MST 300/14-0,5 14,0 28,0 55013304800 40MST 300/16-0,5 16,0 32,0 55013355400 40MST 300/18-0,5 18,0 36,0 55013406600 40MST 300/22-0,5 22,0 44,0 5501345

30 W/m for removing ice and snow from roofs and gutters. Must be used control system with air temperature and moisture sen-sor protecting cables to switch-on in temperature more than +5 °C.

TYPE Suitability Max. loadingFloor heating in living areas Yes 30 W/mOutdoor surface heating Yes 30 W/mFrost protection of pipes Yes 15 W/mPipe heating Yes 15 W/mRemoving ice and snow from roofs and gutters Yes 30 W/m

PAVEMENT1 hardened surface, e.g. fl oor tiling2 humidity sensor (water, snow, ice)3 sand fi ll and the sub-base of the cable4 ECOFLOOR® MAPSV/MADPSP heating cable or MST/MDT mat5 fi rm gravel base (macadam)

DRIVEWAY1 hardened surface, e.g. interlocking pavement2 humidity sensor (water, snow, ice)3 sand bed of the interlocking pavement4 concrete board (protects the heating cable from vehicle load)5 ECOFLOOR® MAPSV/MADPSP heating cable or MST/MDT mat6 fi rm gravel base (macadam)

Page 22: En Catalogue

22

PFP – automatic heating cable with a thermostat, electrical socket connection, the thermostat switches on at +3 °C, 1,5 m con-nection cable with plug, IP 66 coverage.

The heating mat MDT is provided with 1×5 m cold lead

Cables and mats are packing in PE foil.

MADPSP cable, 400 V

OUTPUT [W]

MADPSP 30 W/m

400 V

LENGTH [m] Cat. No.

520 30520 17,1 2323453

860 30860 29,1 2323456

1330 301330 44,6 2323459

1550 301550 51,6 2323462

2000 302000 66,7 2323465

2600 302600 85,5 2323468

2800 302800 93,4 2323471

3600 303600 119,8 2323474

4500 304500 134,9 2323475

5100 305100 166,7 2323477

7700 307700 259,7 2323480

OUTPUT [W]

MADPSP 20 W/m

400 V

LENGTH [m] Cat. No.

420 20420 21,2 2323403

700 20700 35,7 2323406

1100 201100 53,9 2323409

1250 201250 64,0 2323412

1600 201600 83,3 2323415

2100 202100 105,8 2323418

2300 202300 113,7 2323421

3000 203000 143,5 2323424

3600 203600 168,7 2323425

4200 204200 202,2 2323427

6300 206300 317,5 2323430

MDT mat, 230 V, width 0,5 m MDT mat, 400 V, width 0,5 m

OUTPUT [W]

MDT 300 W/m2

AREA [m2]

LENGTH [m] Cat. No.

270 23MDT300/0,9–0,5 0,9 1,8 5500100

450 23MDT300/1,5–0,5 1,5 3,0 5500105

700 23MDT300/2,3–0,5 2,3 4,6 5500110

800 23MDT300/2,7–0,5 2,7 5,4 5500115

1050 23MDT300/3,5–0,5 3,5 7,0 5500120

1350 23MDT300/4,5–0,5 4,5 9,0 5500125

1480 23MDT300/5–0,5 5,0 10,0 5500130

1900 23MDT300/6,3–0,5 6,3 12,6 5500135

2300 23MDT300/7,8–0,5 7,8 15,6 5500140

4000 23MDT300/13,3–0,5 13,3 26,6 5500145

OUTPUT [W]

MDT 300 W/m2

AREA [m2]

LENGTH [m] Cat. No.

520 40MDT300/1,8–0,5 1,8 3,6 5500200

860 40MDT300/2,9–0,5 2,9 5,8 5500205

1330 40MDT300/4,5–0,5 4,5 9,0 5500210

1550 40MDT300/5,2–0,5 5,2 10,4 5500215

2000 40MDT300/6,7–0,5 6,7 13,4 5500220

2600 40MDT300/8,7–0,5 8,7 17,4 5500225

2800 40MDT300/9,3–0,5 9,3 18,6 5500230

3600 40MDT300/12–0,5 12,0 24,0 5500235

4500 40MDT300/15–0,5 15,0 30,0 5500240

7700 40MDT300/25,7–0,5 25,7 51,4 5500245

30 W/m (35 W/m for removing ice and snow from roofs and gutters. Must be used control system with air temperature and moisture

sensor protecting cables to switch-on in temperature more than +5 °C).

MADPSP heating cable, a two-conductor cable with a full protec-tion screen and protection against UV radiation. Suitable for heating outdoor surfaces. Class M2. Cold lead 1×5 m. Ø 6.2–8.9 mm.

TYPE(Ohm/m) Cat. No.

18,00 20007006,40 20007052,70 20007102,00 20007151,20 20007200,72 20007250,60 20007300,36 20007350,25 20007370,18 20007400,08 20007450,04 2000750

OUTPUT [W]

MADPSP 20 W/m

LENGTH [m] Cat. No.

240 20240 12,2 2323203400 20400 20,7 2323206630 20630 31,1 2323209730 20730 36,2 2323212950 20950 46,4 2323215

1200 201200 61,2 23232181300 201300 66,5 23232211700 201700 83,7 23232242000 202000 100,2 23232252400 202400 117,0 23232273600 203600 183,7 23232305100 205100 227,6 2323233

OUTPUT [W]

MADPSP 15 W/m

LENGTH [m] Cat. No.

210 15210 14,0 2323153350 15350 23,6 2323156540 15540 36,3 2323159630 15630 42,0 2323162810 15810 54,4 2323165

1050 151050 70,0 23231681150 151150 75,2 23231711500 151500 95,0 23231741800 151800 111,3 23231752100 152100 133,7 23231773150 153150 209,9 23231804500 154500 255,7 2323183

OUTPUT [W]

MADPSP 25 W/m

LENGTH [m] Cat. No.

270 25270 10,9 2323253450 25450 18,4 2323256700 25700 28,0 2323259800 25800 33,1 2323262

1050 251050 42,0 23232651350 251350 54,4 23232681480 251480 58,5 23232711900 251900 74,8 23232742300 252300 87,2 23232752700 252700 103,9 23232774000 254000 165,3 23232805700 255700 203,5 2323283

OUTPUT [W]

MADPSP 30 W/m

LENGTH [m] Cat. No.

300 30300 9,8 2323303500 30500 16,5 2323306760 30760 25,8 2323309880 30880 30,1 23233121150 301150 38,3 23233151500 301500 49,0 23233181600 301600 54,1 23233212100 302100 67,8 23233242500 302500 80,5 23233253000 303000 93,5 23233274400 304400 150,3 23233306300 306300 183,7 2323333

Cables on dr. Heating circuits

TYPE Suitability Max. loadingFloor heating in living areas Yes 20 W/mOutdoor surface heating Yes 30 W/mFrost protection of pipes Yes 15 W/mPipe heating Yes 15 W/mRemoving ice and snow from roofs and gutters Yes 35 W/m

FOOTBALL PITCH1 grass2 soil layer, approx. 30 cm thick3 sand bedding, approx. 7 cm (compacted) and approx. 3 cm thick fi ll4 ECOFLOOR® MAPSV/MADPSP heating cable or MST/MDT mat

(approx. 20 W/m, 100 W/m2, cable loop spacing 20 cm)5 Levelled solid base (grown, soil)

OUTPUT [W] Type PFP LENGTH

[m]RESISTANCE

[Ω] Cat. No.

20 PFP 2m/20W 2 2 200 233015230 PFP 3m/30W 3 1 440 233015440 PFP 4m/40W 4 900 233015672 PFP 6m/72W 6 700 2330158

136 PFP 10m/136W 10 448 2330160152 PFP 14m/152W 14 286 2330162281 PFP 21m/281W 21 204 2330164337 PFP 30m/337W 30 158 2330166490 PFP 42m/490W 42 104 2330168

Page 23: En Catalogue

23

STAIRS1 wear layer (fl oor tiling)2 fl exible bonding cement3 ECOFLOOR® ADPSV/MAPSV/

MADPSP/PDSP heating cable4 stairs

ADSV+ heating cable, a two-conductor cable with a full protection screen. The sheathing of the cable is resistant against UV radiation and is intended for fl oor heating and the removal of snow and ice from roofs and eaves troughs. 1×3 m cold lead. Ø 5.0 mm.

TYPE Suitability Max. loadingFloor heating in living areas Yes 20 W/mOutdoor surface heating No –Frost protection of pipes Yes 10 W/mPipe heating Yes 10 W/mRemoving ice and snow from roofs and gutters Yes 20 W/m

OUTPUT [W]

Type ADSV+18 W/m

LENGTH [m] Cat. No.

160 18160 8,5 2253100260 18260 14,5 2253105320 18320 18,5 2253110420 18420 24,0 2253115520 18520 28,4 2253120600 18600 34,4 2253125680 18680 37,9 2253130830 18830 46,1 2253135

1000 181000 57,5 22531401200 181200 68,9 22531451500 181500 83,2 22531501700 181700 100,4 22531552200 182200 122,7 22531602600 182600 149,6 2253165

OUTPUT [W]

Type ADSV+20 W/m

LENGTH [m] Cat. No.

160 20160 8,3 2253200270 20270 14,0 2253205340 20340 17,2 2253210450 20450 22,5 2253215540 20540 27,4 2253220640 20640 32,1 2253225720 20720 35,8 2253230870 20870 43,8 2253235

1070 201070 53,5 22532401290 201290 64,4 22532451580 201580 79,0 22532501850 201850 92,4 22532552300 202300 117,3 22532602750 202750 141,4 2253265

OUTPUT [W]

Type ADSV+ 10 W/m

LENGTH [m] Cat. No.

120 10120 11,4 2253000200 10200 18,9 2253005250 10250 23,6 2253010320 10320 31,6 2253015400 10400 36,9 2253020450 10450 45,9 2253025520 10520 49,6 2253030600 10600 63,9 2253035750 10750 75,8 2253040950 10950 87,0 22530451100 101100 114,5 22530501300 101300 131,3 22530551700 101700 158,5 22530602000 102000 194,5 2253065

Heating circuits

ADPSV heating cable, a twin conductor, full protection screened cable with protection against UV radiation. This multipurpose cable is suitable for indoor and outdoor applications. Class M2. Cold lead 1×5 m. Ø 5.0–5.9 mm.

TYPE Suitability Max. loadingOutdoor surface heating Yes 20 W/mFrost protection of pipes Yes 10 W/mPipe heating Yes 10 W/mRemoving ice and snow from roofs and gutters Yes 20 W/m

OUTPUT [W]

Type ADPSV10 W/m

LENGTH [m] Cat. No.

120 10120 11,4 2256010200 10200 18,9 2256015250 10250 23,6 2256020320 10320 31,6 2256025400 10400 36,9 2256030450 10450 45,9 2256035550 10550 56,1 2256040600 10600 63,9 2256045750 10750 75,8 2256050950 10950 87,0 22560551100 101100 114,5 22560601300 101300 131,3 22560651700 101700 158,5 22560702000 102000 194,5 2256075

OUTPUT [W]

Type ADPSV

20 W/mLENGTH

[m] Cat. No.

160 20160 8,3 2252800270 20270 14,0 2252805340 20340 17,2 2252810450 20450 22,5 2252815540 20540 27,4 2252820640 20640 32,1 2252825780 20780 39,3 2252830870 20870 43,8 2252835

1070 201070 53,5 22528401290 201290 64,4 22528451580 201580 79,0 22528501850 201850 92,4 22528552300 202300 117,3 22528652750 202750 141,4 2252870

TYPE(Ohm/m) Cat. No.

38,72 200050014,02 20005058,96 2000510

5,232 20005153,58 2000520

2,568 20005251,714 20005351,382 20005400,926 20005500,638 20005550,424 20005600,31 2000565

0,196 20005700,136 2000575

Cables on drums Heating circuits

ADPSV cable.Packing on carton reel.

PDSP heating cable, a two-conductor cable with a full protection screen and protection against UV radiation. Suitable for heating outdoor surfaces. Class M2. Cold lead 1×5 m. Outer cable diameter – oval 4.5×7 mm.

TYPE Suitability Max. loadingFloor heating in living areas Yes 28 W/mOutdoor surface heating Yes 28 W/mRemoving ice and snow from roofs and gutters Yes 28 W/m

Must be used control system with air temperature and moisture sensor protecting cables to switch-on in temperature more than +5 °C.

(Ohm/m) OUTPUT [W]

PDSP 28 W/m

LENGTH [m] Cat. No.

3,58 640 15210 23,1 23238102,05 890 15350 29 23238150,93 1270 15540 44,8 23238200,42 1900 15630 66,3 23238250,196 2700 15810 100 23238300,136 3400 151050 114,4 2323835

Heating circuits

Page 24: En Catalogue

24

SPECIAL APPLICATIONS

Marking Output W/m 10°C

Temperature tolerance [°C]

Limitation for instalation Max. length at the temperature setting Cat. No.

Min. temp. Min. radiusELSR-M – Frost protection of pipe 6 A 10 A 16 AELSR-M – 10 BO 10 65 –30°C 35 mm 65 m 95 m 105 m 2330310ELSR-M – 15 BO 15 65 –30°C 35 mm 37 m 58 m 65 m 2330315ELSR-N – Frost protection of trays, gutters, roofs, technological heating 16 A 20 A 25 AELSR-N – 20 BO 20 80 –10°C 20 mm 94 m 116 m 146 m 2330320ELSR-N – 30 BO 30 80 –10°C 20 mm 70 m 87 m 109 m 2330330KIT Nr. 4 For connection and termination of self-limiting cables 5030124Cold lead for self-regulating cablesSK 1,5 Limitation: 12 A / 20 m 2000790SK 2,5 Limitation: 20 A / 20 m 2000795SK 4 Limitation: 20 m 2000796

SELF-REGULATING CABLES

Industrial applications: Analyzer lines – prevent condensation Cooling water lines – anti-freeze protection Potable water lines – anti-freeze protection Caustic soda – prevent crystallization under 30 °C

Oils and fats – maintain pumpable viscosity Heating oil – prevent wax dispersion Vessel – anti-freeze and condensation protection

The ELSR self-regulating cables are parallel electrical heating strips consist-ing of a specially fi nished plastic with embedded carbon particles that create an electrical path between two parallel copper bus bars.

OUTPUT [W]

Type PDS1P40 W/m

LENGTH [m] Cat. No.

380 40380 10,0 2325005760 40760 19,0 2325010

1500 401500 38,0 23250203300 403300 82,0 2325030

CONCRETE CURING CABLE CIRCUITSA twin conductor screened cable with a 1×2 m cold lead with plug connection

PDS1P cablefor curing concrete.Packing in PE foil.

PC / PC-S CABLES WITH CONSTANT LINEAR WATTAGE; PCC CIRCUITSCables with constant linear wattage provide a constant wattage per standard metre which enables their shortening and fi nal alterations at the place of installation. They are suitable for applications where higher outputs and thermal resistance are required – the heating of insulation in freezers, pipe heating, process heating, heating of compressor drainage pipes, etc.

The cable consists of two independently insulated supply conductors around which a very thin heating (resistance) wire is wound. It is connected to the supply conductors every 1 m of length – alternately to the phase and to the working conductor. In this way, ‘heating zones’ with a length of 1 m are created. To simplify – these are one-metre long resistance cables connected one after another in a coil. The whole structure is fi tted with a PC-S type silicon jacket, and also with a braided protective screen – termed armouring. The cable can be shortened to the required length; the wattage per 1 m remains the same, however. WARNING: the beginning and end of the cable will not give out heat; heating occurs from the fol-

lowing (preceding) heating zone! In an extreme situation, if the cable is shortened immediately after the connection of the resistance wire to the conduc-tor, this non-heating part can be up to 1 m long – we therefore recommend that a minimum of 1 m of extra cable is ordered.

PCC circuits are made from braided (armoured) cable with a constant linear wattage of 30 W/m – in principle, it is the same kind of cable as the PC-S type, but this is not sold per metre but only as fi nished circuits of set lengths, fi tted with a connecting lead (termed a cold lead) with a length of 1.5 m. Thanks to the silicon jacket and the thermal resistance, they are ideal for the protection of insulation for refrigeration equipment and freezers.

Marking Protective braiding(armouring)

Output [W/m]

Operating temperatures

Temperature resistance

Length of heating zone

Min. order length

Max. length of circuit Cat. No.

PC 25 – 25 −50…60 °C 180 °C 1) 1 m 2 m 80 m 2330210PC-S 25 CuSn (1 mm²) 2330212PC 50 – 50 −50…60 °C 180 °C 1) 1 m 2 m 70 m 2330214PC-S 50 CuSn (1 mm²) 2330216

Operating voltage 230 V / 50 Hz, dielectric strength 1 500 V, cross sectional area of the conductors 2×0.75 mm² (for 25 W/m) and 2×1.5 mm² (for 50 W/m), heating (resist-ance) conductor Ni/Cr (80/20).

Type Output [W]

Linear wattage

Operating temperatures

Temperatureresistance

Length [m]

Resistance [Ω] Cat. No.

PCC 90/3 90

30 W/m −40…60 °C 180 °C 1)

3,0 587,8 2330250PCC 150/5 150 5,0 352,7 2330252PCC 210/7 210 7,0 251,9 2330254PCC 300/10 300 10,0 176,3 2330256

Operating voltage 230 V / 50 Hz, IP 67 coverage, cable diameter 4–4.4 mm; 1×cold lead 1.5 m

1) Thermal resistance of the cable in a switched-off state

THE D-MAT HEATING SHEETIs intended for outdoor use as anti-freeze protection in industrial applications and in the construction industry – for example, for the warming of the earth in excavation pits or of stored friable materials, the warming of cables on reels, main-tenance of warmth in parts of machines or in tools, etc. The sheet is also suitable for use in extreme winter conditions. Technical parameters: IP 56 coverage; heated area 1.2×2.85 m (3.4 m2); total sheet dimensions 1.5×3.05 m; 5 m supply lead ends in a SCHUKO plug.

OUTPUT [W]

Type D-MAT280 W/m2 Cat. No.

950 DM 3,4/280 5505000

Page 25: En Catalogue

25

ECOFLOOR ACCESSORIES

F-BOARD FLOOR INSULATIONF-boards prevent heat losses to the subfl oor structure. Recommended for fl oor reconstructions.

Type Dimensions [mm] Thickness [mm] Packaging [boards in packet]

Packets on the pallet Cat. No.

F-BOARD 6 1250×600×6 6 6 67 5442016F-BOARD10 1250×600×10 10 6 43 5442019

Useful information

Dimensions 600 mm × 1250 mm (0,75 m2 each)

Thickness 6 mm or 10 mm

Weight (kg/board) 1,8 (6 mm) 2,0 (10 mm)

Material Extruded Polystyrene core with Polymer cement outer skin

Density 32 kg/m3

Thermal Conductivity 0,029 W/m°k

Compresive strenght 300 kN/m2

Water absorption (immersion) < 1,5 % by vol

Water absorption (capillary) NilCo-effi cient of Linear Expansion 0,07 mm/mKFlamibility B1

Floor Tiles

Tile Adhesive

Tile Adhesive

ECOFLOOR Mat

F-BOARD

Sub-Floor – or Existing Floor (before renovation)

Quantity supplied Cat. No.

Gutter clip, 1 package = 25 pcs 1 package 2350000

Downpipe clip, 1 package = 25 pcs 1 package 2350003

Chain, 1 package = 10 m 1 package 2350004

GRUFAST fastening strip, 1 unit =10 m 1 unit 4200013

Plastic cable clip, 1 package = 50 pcs 1 package 1200000

Flex strip, 0.5 m length 1 2350002

T strip, 0.5 length 1 2350008

REPAIR KIT

Kit no. 1 for P1P cable repair 1 5030121

Kit no. 2 for ADSV, ASL1P Mat LD and LDTS cable repair 1 5030122

Kit no. 3 for PSV, MADPSP and ADPSV cable and mat repair 1 5030123

Kit no. 4 for connection and termination of self-limiting cables 1 5030124

Kit no. 5 for MADPSP installed under asphalt 1 5030125

OTHER ACCESSORIES

Aluminium self-adhesive tape, 50 mm width, 50 m length 1 2832515

SYFOK-B – fi xation cables for nonstandard eaves and valleysB/20 (20 m) 2350010

B/10 (10 m) 2350011

SYFOK-P – fi xation cables for nonstandard eaves, gutters and valleysP/20 (20 m) 2350012

P/10 (10 m) 2350013

Cable spacer for 4,5 cm loops, 1 package = 25 pcs 1 package 2350014

C-shaped copper roof spacer, 1 package = 25 pcs 1 package 2350005

Page 26: En Catalogue

26

heating fi lmECOFILM®

Ecofi lm heating fi lms use state of the art technology and are primarily used for heating large surfaces. These heating systems are composed of laminated polyester fi lms with a graphite coat-ing, supply leads, and accessories. We offer ECOFILM fi lms in 3 versions: underfl oor heating fi lms (“F”), ceiling fi lms (“C”) and mirror heating fi lms.

The F fi lm is installed directly beneath a fl oating fl oor. Due to its ultra thin profi le (max 0,4 mm thick) the original construction height of the fl oating fl oor is hardly affected. This silent, unobtrusive and dry-laid underfoot heating system is highly reliable and has a long life span. We provide a 10-year warranty for ECOFILM heating fi lms, however their operational life can be longer (30–50 years). The product has been tested according to European standards.

ECOFILM setThe do-it-yourself kit for underfl oor heating may be installed eas-ily, quickly by following the relevant instructions. No professional installation company required. The fi nal electrical connection must be carried out by a qualifi ed electrician. As the Ecofi lm set comes complete for installation, no accessories are needed. We recommend 60 W/m2 for a fl oating wooden fl oor and 80 W/m2 for a fl oating laminated fl oor.

TYPEWIDTH [mm] Output

(W/m2)LENGTH

[m]

Total Output

[W]Cat. No.

TOTAL ACTIVE

Eset 60-1,5/50

600 550 60 W/m2

(230 V)

1,5 50 6652495Eset 60-2/66 2 66 6652500Eset 60-2,5/83 2,5 83 6652503Eset 60-3/99 3 99 6652505Eset 60-4/132 4 132 6652510Eset 60-5/165 5 165 6652515Eset 60-6/198 6 198 6652520Eset 60-8/264 8 264 6652525Eset 60-10/330 10 330 6652530Eset 80-1,5/66

600 550 80 W/m2

(230 V)

1,5 66 6652538Eset 80-2/88 2 88 6652540Eset 80-2,5/110 2,5 110 6652543Eset 80-3/132 3 132 6652545Eset 80-4/176 4 176 6652550Eset 80-5/220 5 220 6652555Eset 80-6/264 6 264 6652560Eset 80-8/352 8 352 6652565Eset 80-10/440 10 440 6652570Eset 80-1,5/117

1000 970 80 W/m2

(230 V)

1,5 117 6652708Eset 80-2/156 2 156 6652710Eset 80-2,5/195 2,5 195 6652713Eset 80-3/234 3 234 6652715Eset 80-4/312 4 312 6652720Eset 80-5/390 5 390 6652725Eset 80-6/468 6 468 6652730Eset 80-8/624 8 624 6652735Eset 80-10/780 10 780 6652740

The Ecofi lm set includes: Ecofi lm F608/55 (F606/55, 1008) electrical heating fi lm

delivered in rolls of various lengths according to the customer’s requirements and layout plan. The heating fi lm is supplied with insulated cut edges and cold leads.

An additional pair of insulation discs for insulating the copper electrodes of the heating fi lm in the event that there is a requirement to shorten the length of the heating fi lm.

Installation manual.

The fi lm is fi tted with two SK AV1.5 cold leads 3 mm in diameter and 5 m long.

WAGOWAGO

Simplifi ed Example of ECOFILM SetDesign Total surface area 4.3×3.1 m. Heating under laminated fl oor. Recommended application: ECOFILM Set 80 W/m2.Note: Heating Parts of the fi lm must not overlap and their minimal dis-tance from fi xtures and wall shall be 5 cm.Owing to the following note, 3 fi lm strips (1000 mm wide) 3 m long and 2 m long and 2 fi lm strips (600 mm wide) 3 m and 2 m long may be used. For the given application it is recommended 2×Eset 80-3/234, 1×Eset 80-3/132, 1×Eset 80-2/156 and 1×Eset 80-2/88 + temperature control.

Page 27: En Catalogue

27

*) delivered in roll, order accessories required for installation

Gentle and safe heating for your comfortHeating fi lm makes an ideal fl oor heating system for laminated or wooden fl oating fl oors. The technical parameters of the heating fi lm ensure that the materials’ temperature resistance values are observed. Health safety standards are also maintained too as the maximum fl oor surface temperature is thermostatically limited to 27 °C. Traditional heaters which utilise a liquid to transfer the heat,operate at for example, signifi cantly higher temperature sand results in a greater fl uctuation in air humidity and undesirable ef-fects on wooden and laminated fl oors. It is hardly surprising that this sophisticated system has been used to safely and comfortably heat in excess of 2,5 million m2 of fl oors throughout Europe and has been warmly endorsed by such leading fl oor manufacturers as PERGO, SCANDIFLOOR, ALLOC, KÄHRS and JUNCKERS.

ECOFILM F – underfl oor heating fi lm

Flexible Ecofi lm heating fi lm is the ideal solution for economical electric underfl oor heating for laminated and wooden fl oating fl oors. The product is ultrathin, yet robust, and is a dry-laid system that is easy to install.

Easy, precise and fast installationThe heating fi lm is produced in rolls 600 mm wide (550 mm heating surface, two 25 mm non-heating edges) and 1 000 mm wide (970 mm heating surface, two 15 mm non-heating edges). Thanks to its special material composition, the heating fi lm may be cut every 10 mm to obtain exactly the required length of strips. The strips are laid side-by-side across the entire heating surface and are interconnected in parallel using cables with connectors. ECOFILM F heating components must neither overlap nor cross one another. This method of laying the fi lm saves time and especially reduces labor costs. Installers will appreciate that the fl oating or wooden fl oor may be laid immediately after the heating fi lm is installed and connected.

ECOFILM F with accessories

Sectional view of laminated (wooden) fl oor (reconstruction)

1 three-layer wooden or laminate fl oating fl oor2 fl oor (limitation) probe in a groove3 PE foil covering, 0.25 mm thick4 ECOFILM® fl oor heating foil5 insulation underlay from extruded polystyrene6 base – concrete, anhydrite, original fl oor etc.

TYPE *WIDTH [mm]

Output [W/m2] Output [W/m] Cat. No.TOTAL ACTIVE

Laminate, wood or real timber fl oorECOFILM F 608/55 600 550 80 44 6652302ECOFILM F 606/55 600 550 60 33 6652301ECOFILM F 604/55 600 550 40 22 6652300ECOFILM F 1008 1000 970 80 78 6652310ECOFILM F 1004 1000 970 40 22 6652308Other types of fl oor fi lmECOFILM F 630 600 500 300 150 6652003ECOFILM F 624 600 500 240 120 6652006ECOFILM F 620 600 500 200 100 6652001ECOFILM F 615 600 500 150 75 6652005

Illustration photo—installation of ECOFILM F608 under fl oating fl oor

ECOFILM F connection in parallel with Mastic

ideal temperature characteristic under-fl oor heating

temperature characteristic

Page 28: En Catalogue

28

ECOFILM C heating fi lms provide an ideal ceiling heating system with balanced heat distribution throughout the room (without temperature gradients). Control of the ECOFILM C’S temperature I achieved by the use of an electronic thermostat which controls the room temperature. As it is a radiant heating system, the same comfort level as achieved by convection heating may be obtained at lower temperatures. Generally, reducing the temperature by 1 °C lowers total heating costs by 6 %.

ECOFILM C – ceiling heating fi lm

Sectional view of ceiling structure

1 load-bearing ceiling structure; 2 thermal insulation; 3 CD load-bearing sections of the plasterboard structure; 4 ECOFILM® ceiling heating foil5 PE foil covering, 0.25 mm thick; 6 plasterboard ceiling (fl oating)

ECOFILM C with connected cold lead

Installation of connector cover

Illustrative photos of ECOFILM C installation on metal joists

Installation: Crimp connector and cold lead

*) delivered in roll, order accessories required for installation

ideal temperature characteristic ceiling radiant heating

temperature characteristic

TYPE *WIDTH [mm]

Output [W/m2] Output [W/m] Cat. No.TOTAL ACTIVE

ECOFILM C 420 400 300 200 60 6652102ECOFILM C 414 400 300 140 42 6652202ECOFILM C 520 500 400 200 80 6652210ECOFILM C 514 500 400 140 56 6652220ECOFILM C 510 500 400 100 40 6652225

Page 29: En Catalogue

29

MIRROR HEATING FILM – perfectly prevents mirror foggingSafety operation. The Ecofi lm MHF fi lm operates at low temperatures and prevents overheating or damage to the mirror. Installation is simple and fast. The MHF fi lm has an adhesive layer (with release backing) that easily sticks to the rear of a mirror. The mirror heater can be wired into the electric circuit of a lighting fi xture so that it is activated whenever the light is switched on. Considering its low input, the heating fi lms operating costs are negligible. The ECOFILM MHF heating fi lm requires no maintenance.

Product Description Amount supplied Cat. No.

Crimp connector for Ecofi lm C and F 1 unit 6651001

Crimp cover for Ecofi lm C 1 unit 6651002

blackblue

Cold lead 1,5 for Ecofi lm C 1 m 665100xCold lead AV 1,5 for Ecofi lm F 1 m 66510x0Cold lead AV 2,5 for Ecofi lm F 1 m 66510x0

Crimp tool 1 unit 6651003

Insulating tape for sealing cut edges of heating fi lm28 mm width/33 m length38 mm width/33 m length

1 roll

6651026

6651028

MASTIC VM connector insulation for Ecofi lm F 38 mm width (1 connector requires 0.1 m) 1m 6651012

WAGO connector (terminal strip) for Ecofi lm set 1 unit 6651007

WITH MHF WITHOUT MHF

TYPE Output [W] Dimension [mm] Cat. No.MHF 12 12,5 274×252 6651850MHF 25 25 274×574 6651860MHF 50 50 524×519 6651870MHF 100 100 524×1004 6651880

1 m cold lead, IP 44, class II

HEAT-PAK for the placement of ECOFILM F, ECOFILM SET heating foil under a carpet or PVCThis underlay with good thermal conductivity enables the installation of fl oor heating directly under a carpet or PVC when it isn’t possible to place the heating cable into a screed (for example in the case of additional installation or reconstruction work). Completely dry installation; raises the fl oor by only 10 mm. The packaging contains 8 boards (4×3 mm thick base boards and 4×4 mm thick covering boards); each of them is coated in a thin layer of adhesive. Laid in two layers, the boards are glued to each other (staggering of joints is necessary – in this way, the joints don’t show through on the fl oor covering). A rigid, 7 mm thick compact construction is created onto which PVC or carpet can be laid (freely or glued). Sold only as whole packages.1 wear layer (PVC, carpet); 2 HEAT-PAK 7 mm two-layer glued underlay; 3 fl oor (limitation) probe in the groove (embedded); 4 PE foil covering, 0.25 mm thick; 5 ECOFILM® fl oor heating foil; 6 insulation underlay from extruded polystyrene; 7 base – original fl oor, concrete anhydrite, etc.

Type Thickness [mm]

Capacity [kg/m3]

Conductivity [W/mK] Strength in fl exure Dimensions of the boards

[m]Package

[m2] Cat. No.

HEAT-PAK 7 3 and 4 770 0,07 > 40 kg / cm2 boards 0,6×1,2 2,88 m2 5442024

FLOOR INSULATION under wood/laminate fl oor with ECOFILM F, ECOFILM SET heating foil1 three-layer wooden or laminate fl oating fl oor; 2 fl oor (limitation) probe in a groove; 3 PE foil covering, 0.25 mm thick; 4 ECOFILM® fl oor heating foil; 5 insulation underlay from extruded polystyrene; 6 base – concrete, anhydrite, original fl oor etc.

Type Thickness [mm]

Bulk density [kg/m2]

Thermal conductivity coeffi cient [W/mK]

Load resistance[t/m2]

Dimensions of insulation [m]

Package [m2] Cat. No.

STARLON 3 3 40 0,0315 5,2 0,5×1,0 boards 5,0 5442003

STARLON 6 6 33 0,0298 6,7 0,5x1,0 boards 5,0 5442006

ECOFILM MHF – mirror fogging prevention

ECOFILM ACCESSORIES

Page 30: En Catalogue

30

ULTRATHERM heating for vivariums and terrariums

Viv Strip – heating strips – due to their size, Viv Strip heating strips are suitable mainly for the warming of selected areas within a vivarium or terrarium housing specifi c types of reptile. Cold lead 2 m. IPX4, class II.

TYPE Output [W] Voltage [V] Dimensions [mm] Cat. No.

Ultratherm Viv Strip 11 11

230 V / 50 Hz

150×410 8510051

Ultratherm Viv Strip 15 15 150×572 8510053

Ultratherm Viv Strip 23 23 150×868 8510055

Ultratherm Viv Strip 32 32 150×1188 8510057

Happy Hamster – heating foil – due to its dimensions this heating foil is suitable for breeders of various types of rodent. Although rodents are not primarily heat-loving animals, in the winter season they enter a certain form of winter hibernation and Happy Hamster heating foil is ideal to help them get through this period in comfort. Cold lead 2 m. IPX4, class II.

TYPE Output [W] Voltage [V] Dimensions [mm] Cat. No.

Ultratherm Happy Hamster 8 230 V / 50 Hz 178×280 8510071

Viv Mat – heating foils – Viv Mat heating foils are larger than Viv Strip strips and so are used when it is necessary to heat the majority of the area of a vivarium or terrarium. Cold lead 2 m. IPX4, class II.

TYPE Output [W] Voltage [V] Dimensions [mm] Cat. No.

Ultratherm Viv Mat 7 7

230 V / 50 Hz

274×142 8510001

Ultratherm Viv Mat 15 15 274×276 8510003

Ultratherm Viv Mat 22 22 274×410 8510005

Ultratherm Viv Mat 30 30 274×572 8510007

Ultratherm Viv Mat 39 39 274×732 8510009

Ultratherm Viv Mat 46 46 274×868 8510011

Ultratherm Viv Mat 64 64 274×1188 8510013

ULTRATHERM HEATING FILMS AND STRIPS

In 2008 Aztec Europe Ltd. joined FENIX holding. Aztec Europe Ltd. has its seat in Great Britain and focuses on the production of special purpose heating elements using mainly ECOFILM foil. These products include heating systems for vivariums and terrariums.

Page 31: En Catalogue

31

ULTRATHERM RADIANT PANELS

ULTRATHERM REGULATION

ULTRATHERM – radiant heating panels – these panels utilise the principle of infrared radiation and are primarily intended for the localised heating and warming of breeding places, large terrariums or dog kennels. They are equipped with a thermal fuse which protects the panel from overheating. It is possible to install them in a vertical position; for horizontal installation it is necessary to order mounting frames. The standard colour is brown; white versions can be ordered and other colours are possible for an additional fee.

Ultratherm Terra-Heat – this thermostat is designed for the check-ing of air or soil temperature in a terrarium or vivarium. It is very simple to use and can be connected to any Ultratherm heating foil or heat strip, heating cable or mat, and also to other heaters available on the market with a maximum output of up to 3 600 W.

TYPE [W] [V] Coverage Dimensions [mm] Weight [kg] Quantity on pallet Cat. No.

Panel ULTRATHERM 100 h 100

230 IP 44

500×320×30 2,5Recommended height of

installationThe apertures used for

hanging the ULTRATHERM panel are on the rear side of the panel. For the installation

of a panel in a horizontal position it is necessary to

order a ceiling frame.

60 8515010

Panel ULTRATHERM 200 h 200 750×320×30 3,7 45 8515015

Panel ULTRATHERM 270 h 270 1000×320×30 5,2 30 8515020

Panel ULTRATHERM 330 h 330 1250×320×30 6,6 30 8515025

Panel ULTRATHERM 400 h 400 1500×320×30 7,9 30 8515030

Ceiling fi xing frame for the horizontal installation of ULTRATHERM 100 panels 5401230

Ceiling fi xing frame for the horizontal installation of ULTRATHERM 200–270 panels 5401231

Ceiling fi xing frame for the horizontal installation of ULTRATHERM 330–400 panels 5401232

CERAMIC HEATING BULBS

Ceramic heating bulbs – heating bulbs (lamps) function on the principle of infra-red radiation – they imitate the sun’s heat radiation and thus create conditions close to those in the natural environment. Heating lamps have a standard screw base which fi ts normal plastic bulb holders; however, due to the higher operating temperatures involved, we defi nitely recommend using ceramic bulb holders. The range, intensity and direction of the heat current can be increased using an aluminium refl ector. Heating bulbs can be used to create different temperature zones within a terrarium.

TYPE Output [W] Voltage [V] Cat. No.

100 W ceramic heating bulb 100

230 V / 50 Hz

8530001

150 W ceramic heating bulb 150 8530002

250 W ceramic heating bulb 250 8530003

Ceramic bulb holder for the heating bulb 8530010

AL refl ector for the heating bulb 8530015

250

Description Cat. No.

Settable temperature range 5–49 °C; measured temperature range 5–49 °C; accuracy: ±1 °C; input wattage 230 V, 50 Hz. 8520003

Page 32: En Catalogue

32

In convection heating, a heating body is used to warm the air which then distributes – transfers - heat as it fl ows over the surfaces of the objects to be heated. Most electrical convector heaters that our fi rm distributes comes with a precise electronic thermostat, as standard, with a contact variation of +0.5 °C.

ECOFLEX®

convectors

ECOFLEX EL – electric convector with electronic thermostat and pilot wire, 4–5 °C setback control, 230 V/50 Hz. Colour: white with gray grid.IP 24, class II; can be installed on C and D fl ammable surfaces; needed clearance (cm): bottom edge, 15 / top edge, 15 / front side, 10

IP 24 Type [W] Dimmensions [mm] Weight [kg] Quantity on pallet Cat. No.

ECOFLEX EL 500 500 360×400×80 3,7 28 5415205ECOFLEX EL 750 750 360×400×80 3,7 28 5415207ECOFLEX EL 1000 1000 440×400×80 4,2 26 5415210ECOFLEX EL 1250 1250 520×400×80 4,9 24 5415212ECOFLEX EL 1500 1500 600×400×80 5,5 20 5415215ECOFLEX EL 1750 1750 680×400×80 6,1 18 5415217ECOFLEX EL 2000 2000 760×400×80 6,8 12 5415220

ECOFLEX SL – electric convector with electromechanical thermostat and pilot wire, 4–5 °C setback control, 230 V/50 Hz. Colour: white with gray grid.IP 24, class II; can be installed on C and D fl ammable surfaces; needed clearance (cm): bottom edge, 15 / top edge, 15 / front side, 10

IP 24 Type [W] Dimmensions [mm] Weight [kg] Quantity on pallet Cat. No.

ECOFLEX SL 500 500 280×400×80 3,7 40 5415105ECOFLEX SL 750 750 360×400×80 3,7 28 5415107ECOFLEX SL 1000 1000 440×400×80 4,2 26 5415110ECOFLEX SL 1250 1250 520×400×80 4,9 24 5415112ECOFLEX SL 1500 1500 600×400×80 5,5 20 5415115ECOFLEX SL 1750 1750 760×400×80 6,1 12 5415117ECOFLEX SL 2000 2000 840×400×80 6,8 12 5415120ECOFLEX SL 2500 2500 1000×400×80 9,0 12 5415125

ECOFLEX G – glass convector with electronic thermostat and pilot wire, 4–5 °C setback control, 230 V/50 Hz. Available in black, red, or yellow-green.IP 24, class II; needed clearance (cm): bottom edge, 15 / top edge, 15 / front side, 15. While stocks last.

IP 24 Type [W] Dimmensions [mm] Weight [kg] Quantity on pallet Cat. No.

ECOFLEX G 10 1 000 500×520×100 14 6 54367X0

ECOFLEX G 15 1 500 660×520×100 18 6 54367X2

ECOFLEX G 20 2 000 820×520×100 27 3 54367X4

Page 33: En Catalogue

33

ATLANTIC F 117-TAC – electric convector with electronic (2500 W electromechanical) thermostat without pilot wire, for areas not requiring precise temperature regulation, such as stores and workshops. Colour: white with white grid.IP 24, class II; can be installed on C and D fl ammable surfaces; needed clearance (cm): bottom edge, 15 / top edge, 15 / front side, 15

IP 24 Type [W] Dimmensions [mm] Weight [kg] Quantity on pallet Cat. No.

ATLANTIC F117-TAC 500 500 370×450×78 3,5 44 5412130

ATLANTIC F117-TAC 750 750 370×450×78 3,5 44 5412132

ATLANTIC F117-TAC 1000 1000 445×450×78 4,1 28 5412134

ATLANTIC F117-TAC 1250 1250 520×450×78 4,8 28 5412136

ATLANTIC F117-TAC 1500 1500 590×450×78 5,4 24 5412138

ATLANTIC F117-TAC 1750 1750 665×450×78 6,0 20 5412140

ATLANTIC F117-TAC 2000 2000 740×450×78 6,5 18 5412142

ATLANTIC 25 2500 890×450×78 7,6 14 5412126

ECOFLEX PREMIER – radiant convector with electronic thermostat and pilot wire, 3.5 °C setback control, 230 V/50 Hz. Colour: white with white grid.IP 24, class II; needed clearance (cm): bottom edge, 15 / top edge, 10 / front side, 100

IP 24 Type [W] Dimmensions [mm] Weight [kg] Quantity on pallet Cat. No.

ECOFLEX PREMIER 1000 450×600×115 4,9 20 5435130

ECOFLEX PREMIER 1500 450×800×115 5,8 12 5435132

ECOFLEX PREMIER 2000 450×1000×115 7,7 12 5435134

CH 2000 B TURBO – portable convector with electromechanical thermostatIP 20, class I; needed clearance (cm): bottom edge, 5 / top edge, 10 / front side, 5

IP 20 Type [W] Dimmensions [mm] Weight [kg] Quantity on pallet Cat. No.

CH 2000B - TURBO 750/1250/2000 580×375×110 5,0 20 5410010

RF BOX, ECOBOX FP – wireless regulation and regulation for pilot wireBy setting the thermostat regulations, it is possible to divide spaces into zones (ECOBOX FP: two zones, RF BOX: three zones) and to set a separate weekly program for each zone. Possibility of “holiday” setting to keep temperatures above freezing (at around 7 ºC) for a set numbers of days (1–99), after which the system automatically returns to its normal regime.

Product Description Cat. No.

RF transmitter Pilot programmable unit for convector heating system. Wireless control 4500320

RF receiver (radio frequency) system: transmitter-receiver. Installation: wall or freely portable. Unit for receiv-ing signal from RF transmitter. Receiver must be installed directly in the convector (Actua, Elite, Aixance) and must be in any convector that is to be controlled by an RF transmitter.

4500322

Ecobox FP

Programmable unit for heating control transmitted over a pilot lead. ECOBOX FP should be installed on one of the convection heaters.The other convection heaters are connected to the main unit through the pilot wire and do not need additional equipment for receiving the signal.

4500317

ELITE PLINTHE ETP – electric convector with electronic thermostat and pilot wire, 4–5 °C setback control, 230 V/50 Hz. Compatible with RF Box. Colour: white with white grid.IP 24, class II; needed clearance (cm): bottom edge, 8 / top edge, 20 / front side, 10

IP 24 Type [W] Dimmensions [mm] Weight [kg] Quantity on pallet Cat. No.

ELITE Plinthe ETP 05 500 600×245×80 3,0 36 5424305

ELITE Plinthe ETP 10 1000 920×245×80 5,0 18 5424310

ELITE Plinthe ETP 12 1250 1080×245×80 6,0 18 5424312

Page 34: En Catalogue

34

THERMOSTATS AND CONTROLSProduct Description Cat. No.

ANALOG ROOM THERMOSTAT

FLASH 25800 10 A, bimetallic thermostat with signaling, without temperature setback, 5–35 °C, IP 30. 4200110

FLASH 25614 Same as a 25800, with temperature setback 3–7 K, accuracy 0.5 K, IP 30. 4200112

EBERLE RTR - E 6202 10 A, with temperature setback 5 K, accuracy 0.5 K, switch, 5–30 °C, IP 30. 4066026

EBERLE RTR - E 6124 10 A, with temperature setback 5 K, accuracy 0.5 K, 5–30 °C, IP 30. 4066020

FENIX-Therm 100 12 A, IP 21, heat differential of 0.5 °C, switch, 0–45 5–30 °C (ambient air), 5–50 °C (fl oor) 4200130

Frame for FENIX-Therm 100 Frame for use in wall mounting. 4200131

DIGITAL ROOM THERMOSTAT

FENIX TFT

Available from the 1st quarter of 2012.

Digital touch screen thermostat; option of selecting the background colour; menu in Czech. Operating modes ‘fl oor only’, ‘room only’, ‘fl oor+room’; option of measurement with the help of two external (fl oor) probes, PWM regulation or fi xed temperature difference. 4 preset and 3 user programmes (10 temperature changes in 15 minute steps, with the shortest time period being 1 hour). Modes: according to the programme, manual mode, holiday, party, non-freezing temperature, switched off. 16 A switching contact; range of temperature settings 5–35 °C in 0.5 °C steps; option of setting the min. and max. fl oor temperature; calibration of sensors. A fl oor probe is included with the thermostat; installation on KU/KP 68.

4200152

FENIX Therm 350

Programmable digital thermostat with Fuzzy-Logic (so-called Intelligent Thermostat) and three separate func-tions: room and fl oor thermostat, fl oor thermostat (factory set) or room thermostat; two preset programs, pos-sible to use own settings. Each day can be set separately, four events per day. Air temp. range/fl oor range 5–37 °C, 16 A, frost protection program, IP 21, power reserve 36 hours, 230 V; equipped with a LED dual function, switch on/off, lock, adaptive function and switch-on time (as a percentage for the last 24 hours, 7 days, 30 days or 365 days).

4200128

EBERLE INSTAT 2 Programmable digital thermostat. Week divided into workdays and weekends, with four changes per day possible. Heating indicator on display, accuracy 0.5 K, 8 A, IP 30, air sensor 5–30 °C. 4065003

EBERLE FIT 3U

Programmable thermostat with PWM regulation or fi xed temperature difference. Operating modes “fl oor only”, “room only”, “fl oor + room”. 13 programmes – 9 pre-set, 4 for users (4 temperature changes per day in 30 minute steps), holiday operation, permanent temperature or permanent attenuation modes, maintenance of a se-lected temperature for a set period. Temperature settable from 5–37°C in 0.5 °C steps (fl oor and room). Option to set the max. and min. fl oor temperature, option of probe calibration. Technical parameters: 16 A switching contact, switch, key lock, back-lit display, automatic change to summer time. Floor probe is part of the package. Placement on KU 68. Lithium battery used for data back-up – the fi rst charging must last at least 24 hours (format-ting of the capacity of the battery), IP 30.

4065005

WATTS 760

Programmable thermostat with Fuzzy-Logic option (so-called Intelligent Thermostat) or fi xed temperature dif-ference (settable at 0.5–7 °C). Operation modes “fl oor only”, “room only”, “fl oor + room”. 5 preset + 2 user programmes - up to 12 temperature changes/day with the user programmes. Room temperature setting 5–37 °C in 0.5 °C steps. Option to set a max. and min. fl oor temperature. Setting of switched wattage for the exact correction of the room temperature, 16 A switching contact, holiday operation, permanent temperature mode, switch, key lock, display backlight, choice of two frames – square, round. IP 21 coverage, placement on KU 68. The back-up of data is provided by a lithium battery – the fi rst charging session must last at least 24 hours (it is for formatting the capacity of the battery), IP 21.

4200123

WATTS 860

Weekly programme, selection of “fl oor only”, “room only”, “fl oor+room” modes, up to 9 temperature chang-es per day, “PARTY” mode –short/term maintenance of a set temperature with an automatic return to the programme, “HOLIDAY” programme – permanent attenuation for a set number of days with an automatic return to the programme, anti-freeze protection. Other functions: child lock, automatic change to summer time, operating hours counter (for the previous 2 days/week/year), option to limit manual temperature correction, setting of the min. and max. fl oor temperature, easy-to-read back-lit (blue) display, data and programme back-up for 10 years. Max. switched wattage is 2 kW. 4 m fl oor probe is part of the package. Placement on KU 68. IP 21.

4200150

TH 810 T

The outlet thermostat adjusts the outlet according to the set room temperature. Temperature range is 5–30 °C (±1 °C). Optional mode for cooling/heating.Maximum switched current is 16 A (3,500 W). Maximum time for backed-up operation is 3 hours. Displays both set and current temperature in the room. Does not allow time programming. IP 20.

4065110

VTM 3000

Selection of weekly or daily programme, selection of the modes “fl oor only”, “room only”, “fl oor + room”. 6× daily switching between the pre-set comfort and attenuation temperatures. Option to manually change the tem-perature with an automatic return to the programme. Other functions: permanent maintenance of comfort or attenuation temperatures, anti-freeze protection, permanent maintenance of manually set temperature (simula-tion of an analogue thermostat), setting of max. and min. fl oor temperature, operating hour counter. Data and programme back-up in the EEPROM memory (up to 10 years), time and date back-up with the help of a large-capacity capacitor – period of back-up 6 hours. Technical parameters: switching contact 16 A / 230 V, max. switched wattage 2 kW, key lock, fl oor probe part of the package. Placement on KU 68. IP 31.

4200134

TEMPERATURE REGULATORS FOR SUPPLEMENTAL UNDERFLOOR HEATING

FENIX Therm 350 – see Digital room thermostat (above) for details 4200128

FENIX-Therm 100– see Analog room thermostat (above) for details

4200130

Frame for FENIX-Therm 100 4200131

WATTS 760 – see Digital room thermostat (above) for details 4200123

WATTS 860 – see Digital room thermostat (above) for details 4200150

Page 35: En Catalogue

35

Product Description Cat. No.

EBERLE FR – E 525 31 With fl oor sensor (4 m), 10–60 °C, 14 A, accuracy 1 K, IP 40, switch. 4070004

EBERLE Fre 525 22 With fl oor sensor (4 m), 10–50 °C, 10 A, with temperature setback, accuracy 1 K, IP 30, Switch 4070006

Aube TH 132-AF Digital thermostat with fuzzy logic, ambient air sensor 5–30 °C, fl oor (3 m) +5 °C to +40 °C, programming: 7 day, 4 time periods/day, 2 temperature settings, accuracy 0.5 K, IP 20. 4200125

Snubber AC130-03

The snubber must be connected into the circuit of the AUBE TH-132AF thermostat if the thermostat switches induction load (e.g. if the heating element is connected via a contactor). If the snubber isn’t connected, spon-taneous resetting of the thermostat may take place. The snubber should be connected as close as possible to the contactor, ideally directly to its contacts.

4200127

EBERLE FIT 3U

Programmable thermostat with PWM regulation or fi xed temperature difference. Operating modes “fl oor only”, “room only”, “fl oor + room”. 13 programmes – 9 pre-set, 4 for users (4 temperature changes per day in 30 minute steps), holiday operation, permanent temperature or permanent attenuation modes, maintenance of a selected temperature for a set period. Temperature settable from 5–37°C in 0.5 °C steps (fl oor and room). Option to set the max. and min. fl oor temperature, option of probe calibration. Technical parameters: 16 A switching contact, switch, key lock, back-lit display, automatic change to summer time. Floor probe is part of the package. Placement on KU 68. Lithium battery used for data back-up – the fi rst charging must last at least 24 hours (formatting of the capacity of the battery).

4065005

TEMPERATURE REGULATION FOR MAIN UNDERFLOOR HEATING

FENIX Therm 350

Programmable digital thermostat with Fuzzy-Logic (so-called Intelligent Thermostat) and three separate func-tions: room and fl oor thermostat, fl oor thermostat (factory set) or room thermostat; two preset programs, pos-sible to use own settings. Each day can be set separately, four events per day. Air temp. range/fl oor range 5–37 °C, 16 A, frost protection program, IP 21, power reserve 36 hours, 230 V; equipped with a LED dual function, switch on/off, lock, adaptive function and switch-on time (as a percentage for the last 24 hours, 7 days, 30 days or 365 days).

4200128

FENIX-Therm 100 12 A, IP 21, heat differential of 0.5 °C, switch, 0–45 5–30 °C (ambient air), 5–50 °C (fl oor) 4200130

Frame for FENIX-Therm 100 Frame for use in wall mounting. 4200131

Aube TH 132-AF – see above for details 4200125

Snubber AC130-03 – see above for details 4200127

EBERLE FIT 3U – see above for details 4065005

WIRELESS REGULATION SUITABLE FOR ECOSUN, MR AND GR PANELS

BPT-SPwireless control unit – transmitter

2–39 °C, adjustable difference of switching 0.1–1.5 °C, PI-PWM, fuzzy logic, 9 select programmes, each programme up to six changes, option of differentiating between an odd and even week, 255 transmitters can be connected to different addresses, simple pairing receiver/transmitter, summer regime function, holiday, party, 2×1.5 V AA power supply, placement on a wall or on a stand, range 35 m in buildings , up to 300 m in open areas, frequency 433.92 MHz, option of control using a text message with the help of an additional GSM module, GST 1, (not included in the price). IP 20.

4500330

SP1wireless receiver – fl ush-mounted

16 A switches, 230 V power supply, IP20, receives information from BPT-SP and confi rms the change, fre-quency 433.92 MHz, indication of operational status with LED diodes, connection in mounting box. 4500332

SP2wireless receiver – wall-mounted

16 A switches, 230 V power supply, IP20, receives information from BPT-SP and confi rms the change, fre-quency 433.92 MHz, indication of operational status with LED diodes, to be mounted on a wall or in mount-ing box.

4500334

SP3wireless receiver – socket

16 A switches, 230 V power supply, IP20, receives information from BPT-SP and confi rms the change, fre-quency 433.92 MHz, indication of operational status with LED diodes, insertion into a 230 V / 16 A socket. 4500336

PH-TS 20 programmable socket

The PH-TS 20 socket is basically an SP3 receiver to which buttons, a display and a temperature sensor were added so that the socket can be programmed directly and the BPT-SP control unit is no longer needed for its operation. The PH-TS 20 programmable socket can also communicate wirelessly with the PH-CJ 37 SW cen-tral unit, and therefore it can also be included in the PocketHome central regulation system. IP 20.

4500342

PH-CJ 37 SW central control unit

The PH-CJ 37 SW central regulation unit is intended for the control of all BPT-SP units in the building. Using it creates a central regulation system for the whole building. The package also includes PocketHome software for the PC, a connecting cable for the PC’s serial COM port and reduction to USB (RS232/USB convertor). The software enables the programming and control of the whole regulation system to be managed signifi -cantly better and more clearly than by using the buttons and display of the PH-CJ 37 SW central control unit. IP 20.

4500340

GSM PH-GST 1 moduleThe GSM module is used for the remote control of the Fenix BPT-SP control unit. With the help of text messages from your mobile phone, the temperature in the room can be regulated or the current state of the control unit can be ascertained. SIM card is not included in the price.

4500338

Page 36: En Catalogue

36

Product Description Cat. No.

INDUSTRIAL ROOM THERMOSTATANALOG WALL-MOUNTED THERMOSTATS WITH INCREASED PROTECTION (IP 54)

EBERLE AZT - A 524510 Built-in space sensor and exterior scale. Ambient air sensor 5–35 °C, 10 A, accuracy 1–5 K. 4066010

EBERLE AZT - A 524410 Built-in space sensor and exterior scale. Ambient air sensor -15–15 °C, 10 A, accuracy 1–5 K. 4066005

EBERLE AZT - I - 524510 Built-in space sensor and interior scale. Ambient air sensor 5–35 °C, 10 A, accuracy 1–5 K. 4066012

EBERLE AZT - I - 524410 Built-in space sensor and interior scale. Ambient air sensor -15–15 °C, 10 A, accuracy 1–5 K. 4066007

INDUSTRIAL THERMOSTATS WITH SEPARATE SENSOR

EBERLE UTR/60 16 A, exterior/interior control, temperature range 0–60 °C, IP 65. 4066037

EBERLE ITR-3 528 800 10 A, temperature range 0–60 °C, exterior and interior control, suitable for mounting on DIN strip, IP 40. 4066040

EBERLE F 891 000 Standard sensor, 4 m, PVC, IP 64. 4066137

EBERLE F 892 002 Placement sensor for UTR and ITR, IP 64 coverage and silicon insulation, 1.5 m.

EBERLE F 893 002 Space sensor for UTR and ITR, IP 30, silicon insulation, 1.5 m.

EBERLE F 897 001 Space sensor without supply cable, IP 65.

CONTROLLERS FOR GUTTERING AND OUTSIDE SURFACE HEATING

Eberle EM 524 89 (one-zone)

Regulator for the heating of eaves troughs, downpipes and outdoor surfaces – pavements and drives. In contrast with a manual or thermostatic controller it enables the achievement of operational cost savings of up to 80 %. Functions: setting of temperature and humidity, operating hours counter, alarm output, delayed switch-ing off, current temperature indicator. Placement on a DIN strip (8 modules), CZ menu. The presence of humid-ity (water, snow or ice) and the outdoor temperature are monitored with the help of external sensors which need to be ordered separately – for eaves troughs or free areas, depending on the application. IP 20.

4600015

Eberle EM 524 90 (two-zone)

A two-zone regulator for the heating of eaves troughs, downpipes and outdoor surfaces. The parameters and functions are the same as for the EM 524 89. However, the regulator enables independent monitoring and control of two applications simultaneously. Basically, these are two EM 524 89 regulators in one. Both zones require the connection of their own set of sensors – for eaves troughs or free areas, depending on the applica-tion – and these need to be ordered separately. IP 20.

4600016

Set of EBERLE sensors for eaves troughs

Humidity (ESD 524 003) and temperature (TFD 524 004) sensor for EM 524 89 and EM 524 90 regulators for controlling the heating of eaves troughs and downpipes. IP 65. 4600051

Set of EBERLE ground sensors

Humidity (ESF 524 001) and temperature (TFF 524 002) sensor for EM 524 89 and EM 524 90 regulators for controlling the heating of outdoor surfaces. IP 65. 4600050

EBERLE DTR-E 3102 Differential thermostat, 230 V, 1 × switching off / 1 × switching contact 16 A, 20–35 °C, IP 65 (can be placed e.g. on the facade). While being operated it requires careful monitoring to attain economical operation. 4066038

OJ Electronik ETR/F-1447A

Differential thermostat; 230 V, 1 × switching contact 16 A, -15–10 °C, IP 20, on DIN rail (3 modules), room sensor (IP 44) included in the price. While being operated it requires careful monitoring to attain economical operation.

4600010

REGULATORS TO CONTROL ATTENUATION AND TIME PROGRAMMABLE SWITCHES

FLASH Programmer 2 SED

The regulator uses a pilot wire for switching between comfort and attenuation temperatures. There is the option to divide a building into two zones and set individual weekly programmes for each of them. A week is divided into 7 days; each day can be allocated one of three pre-set programmes or an individual programme can be created (different for each day). In the case of individual programming, a day is divided into 30-minute inter-vals. There is the option of “holiday” operation – a temperature above freezing point (+7 °C) is maintained for a period of 1 to 99 days, followed by a return to the programme mode. Outputs: sinusoid 230 V / 50 Hz, positive and negative half-wave, the potential of a neutral conductor for all types of convectors and thermo-stats. Dimensions 83×70×17 mm, programme back-up 12 hours, IP 30 coverage. Placement on KU 68.

4100025

REGULATORS FOR REDUCTION OF MAIN CIRCUIT BREAKER VALUE

Three-phase current-load reliever – 6 modules.

BMR HJ 101 One-level regulation with breaking for three phases, 1×3 A, current settings of 1 to 120 A with precision to 1 A. IP 20. 4200230

BMR HJ 102 Two-level regulation with breaking for three phases, 2×3 A, current settings of 1 to 120 A with precision to 1 A. IP 20. 4200231

BMR HJ 103 Three-level regulation with breaking for three phases, 3×3 A, current settings of 1 to 120 A with precision to 1 A. IP 20. 4200232

BMR HJ 303 One-level regulation with separate breaking for individual phases, 3×3 A, current settings of 1 to 120 A with precision to 1 A, size 6 modules. IP 20. 4200030

BMR HJ 306 Two-level regulation with separate breaking for individual phases, 6×3 A, current settings of 1 to 120 A with precision to 1 A, size 6 modules. IP 20. 4200032

BMR HJ 316 Two-level regulation with indirect measuring, separate breaking for individual phases, 6×3 A, current setting from 4 to 1024 A in increments of 4 A. IP 20.

Page 37: En Catalogue

37

1 2

3

4

5

6

7

8

9

10

1 Storage bricks 2 Heating elements 3 Microtherm® insulation 4 Charge controller 5 Bypass system 6 Wall bracket 7 Charge adjustment 8 Vermiculite insulation 9 Fan 10 Auxiliary heating element (optional)

STORAGE HEATERS

ECODYNAMIC – Dynamic Storage HeaterBasic Characteristics and Benefi ts

Electric fan storage heater with controllable heat output according to the Standards DIN 44574, IEC 60531 and the Safety Standard VDE 0720Equipped with a thermomechanical charge controller (liquid fi lled) and a thermomechanical safety controller (bimetal)Airfl ow in two channels inside the core One brick type for all heater models (material: magnesite MgO) High-quality Vermiculite and Microtherm ® insulation (achieving lower surface temperatures and better heat accumulation)Only 25 cm deep No start-up procedure; may be operated by user immediately after installation Tube heating elements (special alloy steel) Radial fl ow fan for quiet and steady heat output Discharge controlled with an external room thermostat* Air outlet with bimetal fl ap system for high and constant heat output (automatic) Auxiliary heating element* installed in the air outlet area Sheet steel casing, phosphatized and enameled; colour: creme-white with gray-brown air outlet grillWith a wall spacer and either supporting feet* or a fl oor plate* Protective cover* for bathrooms

IP X0 Type Input [kW] Max. capacity [kWh] Voltage [V] Dimmensions [mm] Weight [kg] Cat. No.VFMi 20 2,0 16

factory setting 400–3N~50Hz may be changed

by a qualifi ed technician to 230~50Hz

626×672×250 98 5604020VFMi 30 3,0 24 776×672×250 137 5604030VFMi 40 4,0 32 926×672×250 176 5604040VFMi 50 5,0 40 1076×672×250 215 5604050VFMi 60 6,0 48 1226×672×250 254 5604060VFMi 70 7,0 56 1376×672×250 293 5604070

* available on a special order

ECOSTATIC – Static Storage HeaterBasic Characteristics and Benefi ts

Manually controlled electric storage heater Input and output adjustment according to the required comfortAttractively styled to suit modern home and offi ce decor Very low lifetime maintenance Safe, easily controllable and highly reliable Upgraded and adjusted for use in bathrooms (IP X2)

IP X2 Type Input [kW] Max. capacity [kWh] Voltage [V] Dimmensions [mm] Weight [kg] Cat. No.WMX 706 * 0,85 6

230~50Hz

332×700×183 41 5604706WMX 712 1,70 12 560×700×183 77 5604712WMX 718 2,55 18 788×700×183 110 5604718WMX 724 3,40 24 1016×700×183 140 5604724

IP 20 coverage; class I.; electromechanical thermostat for the limitation of charging + electromechanical thermostat for the control of discharging; * the WMX 706 type is without controlling thermostats; option of installation on a C or D fl ammable base; Needed clearance: side edges 75 mm, top edge 250 mm, front wall 300 mm

IP 20 coverage; class I.; electromechanical thermostat for the limitation of charging; option of installation on a C or D fl ammable base; Needed clearance: side and top edge 100 mm, front wall 300 mm

Page 38: En Catalogue

38

ATLANTIC electric water heater

Local heating not only provides you extra comfort, it also conserves electricity and water. Since these heaters are quite small, you can easily build one into a kitchen counter or the cabinet under the sink. Your kitchen’s aesthetics can thereby be preserved.

Principal characteristics and advantagesLow-volume units heat water very close to the place where it is to be used. This eliminates the large losses typical of central hot water sources, where pipes leading from the central boiler sap the water’s heat as they pass through walls.

thermal insulation from polyurethane foam hot water outlet pipe enameled inner pressure tank exchangeable magnesium anode thermostat temperature sensor cold water inlet electrical heating element removable access fl ange thermostat

Type Capacity [l] Voltage [V] Input [W] IP protection Heating time Net weight [kg] Height [mm] Diameter [mm] Cat. No.ATL 10 L 10

220–240

1600 IP 25 0h 24min 8 456 255 5451001 ATL 10 LU 10 2000 IP 24 0h 19min 8 456 255 5451002 ATL 15 L 15 1600 IP 25 0h 35min 9 399 338 5451500 ATL 15 LU 15

2000

IP 24 0h 28min 9 399 338 5451502 ATL 30 L 30

IP 25

0h 57min 13 623 338 5453000 ATL 50 L 50 1h 30min 16 559 433 5455001 ATL 80 L 80 2h 26min 20 791 433 5455010 ATL 100 L 100 3h 02min 22 948 433 5455020 ATL 120 L 120 3h 35min 29 1111 433 5455025 ATL 150 L 150 2200 4h 36min 40 1241 505 5455030

HAND DRYERS – electric hot-air units with fans for hands drying. Wall-mountable. Automatic sensor switch ensures hygienic operation. Type ZY - 202 (metal) – while stocks last.

Type Output Switching sensor

Air temperature Tension Dimension

[mm]Weight

[kg] Cat. No.

ZY - 203 A (plastic) 1800 W 14–18 cm 50–70°C ~230 V 50 Hz

240×240×240 2,5 5440010ZY - 202 A (metal) 2700 W 12–18 cm 45–55°C 361×242×156 5,0 5440005

SUPPLEMENTARY PRODUCTS

TUBULAR HEATING ELEMENTS – with an electric heating insert. Intended primarily for bathrooms – suitable for drying bath towels, hand towels etc.

ZY - 203 A (plastic)

ZY - 202 A (metal)

ELECTRIC TOWEL DRYERS are intended mainly for use in bathrooms, washrooms, showers or kitchens for the drying of damp towels, bath towels, tea towels etc. The installation is simple – the dryer is attached to the wall using three plastic grips and the supply lead is connected to a standard socket. The heating element is protected from overheating by a thermal fuse; the element doesn’t contain any fi lling and therefore there is no danger of freezing, air intake or leakage of the liquid.

Type STR - CR (chrome) – while stocks last.

Type Colour Width [mm]

Height [mm]

Depth [mm]

Weight[kg] Cat. No.

STR - W white 590 662 25 3,9

5441006STR - CR chrome 5441007

Output 100 W, voltage 230 V / 50 Hz, IP 44 coverage, insulation class I., switch with a light which signals operation, 1.6 m long straight supply cable with a plug.

IP 65 coverage. Voltage 230 V / 50 Hz. White RAL 9016; fi lled with non-freezing mixture, 1 m coiled connection cable (extends to 3,5 m) with plug. Mounting brackets are included with the product. The heating element is without a thermostat. It can be combined with a TH 810 T plug in thermostat.

y

Type Wattage Width [mm]

Height [mm]

Depth [mm]

Weight[kg] Cat. No.

K-E – fl at

K-E 450×960 300 450 960 90 11,5 5441402K-E-600×960 400 600 960 90 13,0 5441404K-E-450×1320 400 450 1320 90 15,8 5441406K-E-600×1320 600 600 1320 90 18,0 5441408K-E-750×1680 900 750 1680 90 27,0 5441410KDO-E – rounded

KDO-E 450×960 300 450 960 120 11,5 5441412KDO-E 600×960 400 600 960 120 13,0 5441414KDO-E 450×1320 400 450 1320 120 15,8 5441416KDO-E 600×1320 600 600 1320 120 19,0 5441418KDO-E 750×1680 900 750 1680 120 27,0 5441420

Page 39: En Catalogue

ArgentinaArmeniaAustraliaAustriaBelorussiaBeneluxBosnia and HerzegovinaBrazilBulgaria

CanadaColumbiaCroatiaCyprusCzech RepublicDenmarkEstoniaFinlandFranceGeorgia

GermanyGreat BritainGreeceHungaryChileIranIrelandItalyJapanKorea

KazakhstanKingdom of JordanLatviaLithuaniaMacedoniaMaltaMontenegroNetherlandsNew ZealandNorway

PolandPortugalRomaniaRussiaSerbiaSlovakiaSloveniaSpainSwedenSwitzerland

SyriaTurkeyUkraineUruguayUSA

EXPORT MARKETS

www.fenixgroup.eu

Page 40: En Catalogue

HEADQUARTER FENIX GROUP a.s.Šárecka 37, 160 00 Praha 6, Czech Republic E-mail: [email protected]

FLEXEL INTERNATIONAL LTD.Glenrothes, Fife, Scotland www.fl exel.co.ukE-mail: sales@fl exel.co.uk

CEILHIT, S.L.Poligono Industrial Cami RalC/Galileo 38-40, 08850 Gava, SpainE-mail: [email protected]

FENIX TRADING s.r.o. Slezská 2, 790 01 Jeseník, Czech Republic

Tel.: +420 584 495 111, 584 495 302Fax: +420 584 495 303

E-mail: [email protected]

EL INTERNATIONAL LTD.h f l d

BRANCH STORE FENIX BOHEMIA

Vejvanov 17, 338 28 RadniceCzech Republic

E-mail: [email protected]

IT, S.L.I d l C R l

FENIX SLOVENSKO s.r.o.Iliašská cesta 86

974 01 Bánská Bystrica, SlovakiaE-mail: [email protected]

BRANCH SFENIX BOH

PRODUCTION PLANTFENIX s.r.o., Jaroslava Ježka 1338/18a790 01 Jeseník, Czech RepublicE-mail: [email protected]

ACSO11 bis, boulevard carnot – 81270

Labastide-Rouairoux, FranceE-mail: [email protected]

www.fenixgroup.euFENIX TRADING s.r.o. Slezská 2, 790 01 Jeseník, Czech Republic;

Tel.: +420 584 495 111, 584 495 302; Fax: +420 584 495 303; E-mail: [email protected]


Recommended