Date post: | 21-Jan-2016 |
Category: |
Documents |
Upload: | godwin-james |
View: | 218 times |
Download: | 0 times |
Environmental Express Webinar HotBlock Systems – Precision Heat
with Various Uses
12/08/15
Decades of Digestions – 1970s
Hot plate Fume hood Gloves Safety glasses
Hot plate Fume hood Gloves Safety glasses Lab coat
Decades of Digestions – 1980s
Sample contamination Safety Accuracy Absence of uniform
heating Transfer steps
Problems with Early Digestion Procedures
Decades of Digestions – 1990s
Digestion methods improve
Environmental Express introduces HotBlockTM Digestion Systems
Metals-free construction eliminates contamination source
Temperature uniformity results in time-based digestions vs. volume-based digestions
Samples of similar matrices finish digesting at the same time
Single use digestion supplies eliminate glassware, sample transfer steps, and multiple contamination sources
Benefits of Using HotBlock™ Digestion Systems
Teflon®-coated graphite block provides uniform heating
Kydex® housing is fire-resistant and acid-resistant
Benefits of Using HotBlock™ Construction
Silicone heating mat evenly applies heat for temperature uniformity
Easy-to-use controller allows for precise temperature control
Benefits of Using HotBlock™ Construction
HotBlock
Most basic application is heated digestion of samples
Metals digestions
‘Block Digesters’ are specifically mentioned in 200.2, 200.5, 200.7, and 200.8
HotBlock
Other digestions
Phosphorous – 365.1
Cr6+ - 3060A/7196A
Nitrogen – Alkaline persulfate digestions SM4500N-C
Mercury – 245.1
HotBlock – Industrial Hygiene
GhostWipe Lead and Beryllium
Method requires ‘rigid walled container’ for transport
Some methods require stirring or agitation while heating
HotBlock & StirBase allow for multiple samples to be heated and stirred at once
Hexavalent Chromium by SW846 3060A
ASTM F963 – Lead in toys
Stirring Capabilities
Adds some automation to the digestion process.
Controller allows for ramping, soaking, changes in temperature, and automatic shut-off.
Can control up to 2 HotBlock Pro blocks at once.
HotBlock Pro
HotBlock - Distillations
SimpleDist
Suitable for ammonia and cyanide distillation
Phenol currently in development
Basic 12 place block Fits other 50 mL
HotBlock systems
Eliminates cooling water and most glassware
HotBlock – Organic Extractions Soil-Cell System
Based on SW-846 3546 Utilizes a HotBlock rather
than a microwave Stainless steel cells
contain the soil and solvent mixture
Creates same temperature and pressure conditions in the cell that the microwave creates in it’s cells
Working with EPA on global acceptance of apparatus
Available Models 15 mL cups
SC196 - 96 wells 50 mL cups
SC100 – 36 wells SC154 – 54 wells C6002 – 12 wells
100 mL cups SC150 – 25 wells SC151 – 35 wells
All versions, except 12 well, also available in Pro models.
Custom HotBlocks Custom blocks are available Must fit into existing graphite footprint –
12”x12” or 12”x18” Send us sample vessel to measure May require one time additional tooling fee
Examples ISM Multiple cup sizes in one block Centrifuge tubes
There are times when a HotBlock is not feasible
Hot plate allows for larger digestion vessels such as beakers
Important to keep the same type of construction and heating technology in the hot plate as the HotBlock for the best performance
Special Digestions
Thank you for attendingQuestions?
12/08/15