+ All Categories
Home > Documents > Essen Fair_Structural Calculation.kamman Group

Essen Fair_Structural Calculation.kamman Group

Date post: 14-Apr-2018
Category:
Upload: ekons-doo
View: 217 times
Download: 0 times
Share this document with a friend

of 17

Transcript
  • 7/29/2019 Essen Fair_Structural Calculation.kamman Group

    1/17

    STRUCTURAL CALCULATION

    ESSEN FAIR

  • 7/29/2019 Essen Fair_Structural Calculation.kamman Group

    2/17

    STAND: KAMMAN GROUP

  • 7/29/2019 Essen Fair_Structural Calculation.kamman Group

    3/17

    TABLE OF CONTENTS

    1. INTRODUCTION 21.1 ARCHITECTURAL INPUTS 21.2 LOAD ANALYSIS 41.2.1 DEAD LOAD 41.2.2 HORIZONTAL LOAD 41.2.3 LOAD COMBINATIONS 41.3

    STRUCTURAL MODEL 5

    1.4 STRUCTURAL DESIGN 71.4.1 STRUCTURAL DIMENSIONING 112. DRAWINGS 13

  • 7/29/2019 Essen Fair_Structural Calculation.kamman Group

    4/17

    KAMMAN GROUP Stand, Messe Essen

    1. INTRODUCTION

    The stands has to be designed for Fair Trade in Essen, Germany.Area is 7 x 3m, height is 2.5m 3.5m.Walls are made by plywood sheets, strengten with timber profiles.

    1.1 ARCHITECTURAL INPUTS

  • 7/29/2019 Essen Fair_Structural Calculation.kamman Group

    5/17

    KAMMAN GROUP Stand, Messe Essen

  • 7/29/2019 Essen Fair_Structural Calculation.kamman Group

    6/17

    KAMMAN GROUP Stand, Messe Essen

    1.2 LOAD ANALYSIS

    Stand construction safety1

    Stands, including all equipment and exhibits and advertising matter are to be constructed with suchstability as to pose no danger to public safety and order, and in particular to life and health. Theexhibitor is responsible for structural safety and must provide proof of this.

    Free-standing structural elements and special structures (e.g. free-standing walls, high exhibits, highdecorative elements) which can fall over must be rated at least for a horizontally acting equivalentdistributed load qh:

    qh1 = 0.125 kN/m2 up to 4.00 m high from the upper edge of the floor

    qh = 0.063 kN/m2 for all surfaces above 4.00 m high.

    The respective elevation area is the reference area. The relevant verifications to be prepared are to besubmitted to MESSE ESSEN GmbH in a form that can be examined.

    Approval of stand construction

    On the assumption that the technical regulations have been observed in the design and construction ofthe stand, there is no requirement for submission of drawings for approval in respect of single-storeystand structures up to 2.50 m in the halls.

    1.2.1 DEAD LOAD

    MATERIALS

    Assumptions/Conversions Loading

    Pl d

    Sheets: BxL=2500 x 1000 mm,

    Thi k 9 5 L1 0 0474 KN/

    2

  • 7/29/2019 Essen Fair_Structural Calculation.kamman Group

    7/17

    KAMMAN GROUP Stand, Messe Essen

    1.3 STRUCTURAL MODEL

  • 7/29/2019 Essen Fair_Structural Calculation.kamman Group

    8/17

    KAMMAN GROUP Stand, Messe Essen

    Dead load

  • 7/29/2019 Essen Fair_Structural Calculation.kamman Group

    9/17

    KAMMAN GROUP Stand, Messe Essen

    1.4 STRUCTURAL DESIGN

  • 7/29/2019 Essen Fair_Structural Calculation.kamman Group

    10/17

    KAMMAN GROUP Stand, Messe Essen

    Reactions

  • 7/29/2019 Essen Fair_Structural Calculation.kamman Group

    11/17

    KAMMAN GROUP Stand, Messe Essen

    TOWER OVERTURNING CHECK

    Case 1:

  • 7/29/2019 Essen Fair_Structural Calculation.kamman Group

    12/17

    KAMMAN GROUP Stand, Messe Essen

    Case 2

    Wind is loading the largest (backside) panel. Rotation is around one of triangles sides.

    Vertical loads:

    PlywoodWalls.......... 0,0474 KN/m2

    3. Backside: Area = 3.12 m2

    4. Front sides: Area= 2 x 1.05m2

    F1 = 0,0474x3.12 = 0.148 KN

    F2 = 0,0474 x 1.05 =0.05 KN

    The brunts distances from turning line3:

    L1 = 0,3 m

    L2 = 0,3 m

    Mv = 0.148 x 0.3 + 0,05 x 0,3 = 0,0594 KNm

    Horizontal loads:

    2. Wind load 0,125 KN/m2Area: 3.12 m2

    Fw= 0,387KN

    Fws = 0.387 cos 45 = 0.274 KN

    Distance from rotation point:

    H = 1,75 m

    Mh = 0.274 x 1.75 =0,479 KNm

    Mv MH

    For stabilizing of overturning of wall it must be added aditional vertical weight on wall bottom.

    Moment of additional vertical weight must be: Mh - Mv = 0.479 0.06 = 0.419 KNm

    Moment arm is 0,3m. Thus, total additional vertical load must be at least 1.39 KN.

    ON BOTTOM OF TRIANGLE TOWER TO ADD STEEL PLATE ( 550 x 550 x 60 mm)4

    AS HORIZONTAL LOAD COUNTERWEIGHT!

  • 7/29/2019 Essen Fair_Structural Calculation.kamman Group

    13/17

    KAMMAN GROUP Stand, Messe Essen

    1.4.1 STRUCTURAL DIMENSIONING

    The most loaded beam:

    TIMBER STRUCTURE CALCULATIONS----------------------------------------------------------------------------------------------------------------------------------------CODE: EN 1995-1:2004/A1:2008

    ANALYSIS TYPE: Member Verification----------------------------------------------------------------------------------------------------------------------------------------

    CODE GROUP:MEMBER: 14 Timber Beam_14POINT: 1 COORDINATE: x = 0.00 L = 0.00 m----------------------------------------------------------------------------------------------------------------------------------------LOADS:Governing Load Case: 2 WIND2

    ----------------------------------------------------------------------------------------------------------------------------------------

    MATERIAL D70gM = 1.30 f m,0,k = 70.00 MPa f t,0,k = 42.00 MPa f c,0,k = 34.00 MPaf v,k = 5.00 MPa f t,90,k = 0.60 MPa f c,90,k = 13.50 MPa E 0,moyen = 20000.00 MPa

    E 0,05 = 16800.00 MPa G moyen = 1250.00 MPa Service class: 1 Beta c = 1.00----------------------------------------------------------------------------------------------------------------------------------------

    SECTION PARAMETERS: 80x80

    ht=8.0 cmbf=8.0 cm Ay=32.00 cm2 Az=32.00 cm2 Ax=64.00 cm2tw=4.0 cm Iy=341.33 cm4 Iz=341.33 cm4 Ix=505.2 cm4tf=4.0 cm Wely=85.33 cm3 Welz=85.33 cm3

    ----------------------------------------------------------------------------------------------------------------------------------------STRESSES ALLOWABLE STRESSESSig_c,0,d = N/Ax = 0.01/64.00 = 0.00 MPa f c,0,d = 15.69 MPa

    Sig_m,y,d = MY/Wy= 0.00/85.33 = 0.03 MPa f m,y,d = 32.31 MPaSig_m,z,d = MZ/Wz= 0.08/85.33 = 0.89 MPa f m,z,d = 32.31 MPa

    d * / f d

  • 7/29/2019 Essen Fair_Structural Calculation.kamman Group

    14/17

    KAMMAN GROUP Stand, Messe Essen

    Tower columns

    STEEL DESIGN----------------------------------------------------------------------------------------------------------------------------------------CODE: EN 1993-1:2005/AC:2009, Eurocode 3: Design of steel structures.ANALYSIS TYPE: Member Verification----------------------------------------------------------------------------------------------------------------------------------------CODE GROUP:MEMBER: 31 Column_31 POINT: 1 COORDINATE: x = 0.00 L = 0.00 m----------------------------------------------------------------------------------------------------------------------------------------LOADS:Governing Load Case: 3 Comb.1 1*1.35+2*1.50----------------------------------------------------------------------------------------------------------------------------------------MATERIAL:

    STEEL fy = 235.00 MPa----------------------------------------------------------------------------------------------------------------------------------------

    SECTION PARAMETERS: Kamman 30mmh=3.0 cm gM0=1.00 gM1=1.00b=3.0 cm Ay=1.80 cm2 Az=1.44 cm2 Ax=3.24 cm2tw=0.3 cm Iy=3.99 cm4 Iz=3.99 cm4 Ix=6.72 cm4tf=0.3 cm Wply=3.29 cm3 Wplz=3.29 cm3----------------------------------------------------------------------------------------------------------------------------------------

    INTERNAL FORCES AND CAPACITIES:N,Ed = 0.25 kN My,Ed = -0.02 kN*m Mz,Ed = 0.01 kN*m Vy,Ed = -0.10 kNNc,Rd = 76.14 kN My,pl,Rd = 0.77 kN*m Mz,pl,Rd = 0.77 kN*m Vy,T,Rd = 21.99 kNNb,Rd = 70.84 kN My,c,Rd = 0.77 kN*m Mz,c,Rd = 0.77 kN*m Vz,Ed = 0.06 kN

    MN,y,Rd = 0.77 kN*m MN,z,Rd = 0.77 kN*m Vz,T,Rd = 17.59 kNTt,Ed = -0.06 kN*mClass of section = 1

    ----------------------------------------------------------------------------------------------------------------------------------------

  • 7/29/2019 Essen Fair_Structural Calculation.kamman Group

    15/17

    KAMMAN GROUP Stand, Messe Essen

    2. DRAWINGS

    No DRAWING NAME SCALE

    1 STAND KAMMAN Drawing 1 1:50

    2 STAND KAMMAN - Drawing 2 1:50

  • 7/29/2019 Essen Fair_Structural Calculation.kamman Group

    16/17

    1 : 50

  • 7/29/2019 Essen Fair_Structural Calculation.kamman Group

    17/17

    Section A - A

    Section B - B

    W 4

    1 : 50

    PLYWOOD QUANTITY

    WALL W1

    2500 x 1250 ........... 6 pcs2000 x 1200 ........... 2 pcs

    WALL W2

    2500 x 1040 ........... 2 pcs

    WALL W3

    2500 x 1000 ........... 3 pcs

    WALL W1

    COLUMNS L=2.5m... 7 pcsBEAMS L=7m........... 2 pcs

    WALLS

    3500 x 897 ............ 1 pcs3500 x 600 ............. 3 pcs

    STEEL SQUARE PIPE30x30x1.8mm

    COLUMN L=3.5m...... 4 pcsFLOOR BEAM L=1m.. 1 pcs

    1 : 20

    2000 x 1100 ........... 2 pcs

    2000 x 950 ............. 2 pcs

    2500 x 1000 ........... 2 pcs2000 x 950 ............. 2 pcs

    TIMBER QUANTITY

    WALL W4

    2500 x 200 ............. 2 pcs

    2500 x 1000 ........... 2 pcs

    WALL W2

    COLUMNS L=2.5m... 3 pcsBEAMS L=3m........... 2 pcs

    WALL W3

    COLUMNS L=2.5m... 3 pcsBEAMS L=1m.............3 pcs

    WALL W4

    COLUMNS L=3m..... 3 pcs

    BEAMS L=3m........... 2 pcs

    COLUMNS L=1m..... 1 pcs

    TRIANGLE POLE QUANTITY

    PLYWOOD


Recommended