The advantages of Industrial wireless communication
1. Less wire Space and wiring time
Construction and the wiring cost of the communication cable can be reduced.
Also the construction time can be shortened.
2. Communication line exclusion from moving area
It’s possible to install this system in places where wiring is difficult.
3. Flexible to change & corrections
It is possible to correspond to flexible changes & corrections of the facility.
2
Sep.2017
Cou
rtes
y of
CM
A/F
lody
ne/H
ydra
dyne
▪ M
otio
n Con
trol
▪ H
ydra
ulic
▪ P
neum
atic
▪ E
lect
rica
l ▪ M
echa
nica
l ▪ (
800)
426
-548
0 ▪
ww
w.c
maf
h.co
m
3
Features
- Maximum 1280 Inputs/1280 Outputs
(Up to 127 slave registries)
- Min. 250ms slave connection time
- Min. 5ms latency of I/O response
- Approx. 10m communication distance
(Master to Slave)
Sep.2017
Cou
rtes
y of
CM
A/F
lody
ne/H
ydra
dyne
▪ M
otio
n Con
trol
▪ H
ydra
ulic
▪ P
neum
atic
▪ E
lect
rica
l ▪ M
echa
nica
l ▪ (
800)
426
-548
0 ▪
ww
w.c
maf
h.co
m
4
Features (Cont’d)
The SMC wireless communication system provides a stable
and reliable network that meets the needs of the Factory
Automation environment.
Noise
Resistance
- Adopt radio frequency that is higher than the frequency of the noise
source generated by a factory facilities [ 2.4GHz ISM band ]
- Prevention of interference with other wireless communication by the
Frequency Hopping
- Interference reduction to the other communication equipment in the
same areas by reduce radio power. [1mW or less]
Sep.2017
Cou
rtes
y of
CM
A/F
lody
ne/H
ydra
dyne
▪ M
otio
n Con
trol
▪ H
ydra
ulic
▪ P
neum
atic
▪ E
lect
rica
l ▪ M
echa
nica
l ▪ (
800)
426
-548
0 ▪
ww
w.c
maf
h.co
m
5
Features (Cont’d)
High speed
connection
-Quick start operation from power supply turn on or tool change
applications. [ Minimum 0.25 seconds]
- Quick response of signal thanks to compact data packets and the
time synchronous system. [ Minimum 5 msec]
- The encryption prevents process data manipulation and leak outside
the network.
- To provide a technology capable of realizing communication with high
quality without interruption. [Re-try, Auto synchronous, CRC check ]
High speed
response
High
reliability
Sep.2017
Cou
rtes
y of
CM
A/F
lody
ne/H
ydra
dyne
▪ M
otio
n Con
trol
▪ H
ydra
ulic
▪ P
neum
atic
▪ E
lect
rica
l ▪ M
echa
nica
l ▪ (
800)
426
-548
0 ▪
ww
w.c
maf
h.co
m
6
Wireless modules
To
sole
noid
valv
es
To
I/O
Units
To
sole
noid
valv
es
To
I/O
Units
Ex. Master unit I/O unit connectionEx. Slave unit I/O connection
MAC adrs: 00:26:C6:00:0A:01
PID : xx:xx:xx:xx
Wireless master Wireless Slave
NFC antenna
LED display
Ethernet I/F
Sep.2017
Cou
rtes
y of
CM
A/F
lody
ne/H
ydra
dyne
▪ M
otio
n Con
trol
▪ H
ydra
ulic
▪ P
neum
atic
▪ E
lect
rica
l ▪ M
echa
nica
l ▪ (
800)
426
-548
0 ▪
ww
w.c
maf
h.co
m
I/O modules + valve outputs capability
Max. 32 coilsMax. 9 x I/O modules
I/O modules
1 Digital inputs
(M12/M8/D-sub/spring
terminal)
2 Digital outputs
(M12/D-sub/Spring terminal)
3 Digital I/O
(D-sub/Spring terminal)
4 Analog IO
(M12 connector)
Wireless master / slaves
7
Sep.2017
Cou
rtes
y of
CM
A/F
lody
ne/H
ydra
dyne
▪ M
otio
n Con
trol
▪ H
ydra
ulic
▪ P
neum
atic
▪ E
lect
rica
l ▪ M
echa
nica
l ▪ (
800)
426
-548
0 ▪
ww
w.c
maf
h.co
m
NFC I/F for parameter settings and I/O monitoring.
- NFC reader/writer
Setting items for master / slave
- Addressing
- I/O size
- Valve status in error condition (Hold / Clear)
NFC:Near Field Communication
8
Sep.2017
Cou
rtes
y of
CM
A/F
lody
ne/H
ydra
dyne
▪ M
otio
n Con
trol
▪ H
ydra
ulic
▪ P
neum
atic
▪ E
lect
rica
l ▪ M
echa
nica
l ▪ (
800)
426
-548
0 ▪
ww
w.c
maf
h.co
m
9
Application Example1; Handing robot / Tool changer
JIG A JIG B
Robot
JIG C JIG A JIG B JIG C
Robot
Master
Slave
-Communication line exclusion
from moving area.
- It’s possible to operate the JIG’s
independently. (A power supply
is required)
With wired communication With wireless communication
SlaveSlave
Periodic maintenance is required
Control Panel
Confidential / May. 2017 (for MAKINO)
Cou
rtes
y of
CM
A/F
lody
ne/H
ydra
dyne
▪ M
otio
n Con
trol
▪ H
ydra
ulic
▪ P
neum
atic
▪ E
lect
rica
l ▪ M
echa
nica
l ▪ (
800)
426
-548
0 ▪
ww
w.c
maf
h.co
m
10
Application Example2; Welding robot facility ;Communication line that
becomes unnecessary
by wireless
A robot
panel
A robot
panel
A robot
panel
A robot
panel
A robot
panel
R
H
R
H
R
JIG #10
slaveMaster
Network
HHandling
robot
RWelding
robot
JIG #20
slaveslave
JIG #30
slave
Confidential / May. 2017 (for MAKINO)
Cou
rtes
y of
CM
A/F
lody
ne/H
ydra
dyne
▪ M
otio
n Con
trol
▪ H
ydra
ulic
▪ P
neum
atic
▪ E
lect
rica
l ▪ M
echa
nica
l ▪ (
800)
426
-548
0 ▪
ww
w.c
maf
h.co
m
11
Application Example2; Turn table
PA
NE
L
Master
slave
slave
slave
slave
slave
slave
slave
Assembly2
Loder
Assembly
1
Un-Loder
sla
ve
Only Air and power
>Communication line is
unnecessary
Sep.2017
Cou
rtes
y of
CM
A/F
lody
ne/H
ydra
dyne
▪ M
otio
n Con
trol
▪ H
ydra
ulic
▪ P
neum
atic
▪ E
lect
rica
l ▪ M
echa
nica
l ▪ (
800)
426
-548
0 ▪
ww
w.c
maf
h.co
m
12
Specifications - wireless related
Items Specifications
SMC original protocol
( Physical layer : IEEE802 .15 .4 ) Radio Protocols
SMC proprietaryEncription
Frequency Hopping ( FHSS )Signal spread
method
2 .4GHz ISM band (2 .403 - 2 .481 GHz ) / 79 chFrequency /CH
250 kbpsCommunication
data speed
Min 5msec (*)Data latency
Master - Slave : approx . 10 m (*)Communication
distance
Ethernet/ IP , Field bus
(*) Depending on environment and connection number of slaves .
Sep.2017
Cou
rtes
y of
CM
A/F
lody
ne/H
ydra
dyne
▪ M
otio
n Con
trol
▪ H
ydra
ulic
▪ P
neum
atic
▪ E
lect
rica
l ▪ M
echa
nica
l ▪ (
800)
426
-548
0 ▪
ww
w.c
maf
h.co
m
13
工事設計認証Japan
Countory Standard
CE Marking ( R&TTE Directive )EU
FCCUSA
Specifications - wireless related (Cont’d)
RF laws
Sep.2017
Cou
rtes
y of
CM
A/F
lody
ne/H
ydra
dyne
▪ M
otio
n Con
trol
▪ H
ydra
ulic
▪ P
neum
atic
▪ E
lect
rica
l ▪ M
echa
nica
l ▪ (
800)
426
-548
0 ▪
ww
w.c
maf
h.co
m