+ All Categories
Home > Documents > Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples...

Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples...

Date post: 23-Feb-2018
Category:
Upload: ngothu
View: 215 times
Download: 0 times
Share this document with a friend
39
1of 39 Examples Introduction This appendix offers the following examples: Rational Method example problem hyetograph example developed from NRCS 24-hour rainfall distributions hyetograph example using the Balanced Storm Method Muskingham Method Standard Step Method storm drain design Rational Method Example Problem Problem Statement. Both a topographic map and field survey show the area of the drainage basin upstream of a proposed highway culvert, which is found to be 19 hectares (Figure F- 1). In terms of soils and surface cover, the existing drainage area is reasonably homogeneous with mostly light woodlands and brush. There appear to be two distinct flow paths converging in the lower area. Local zoning allows light industry in an area adjacent to the highway. The combination of highway improvements and growth in the region make full development of the zoned area attractive and likely within the next few years. The drainage basin is in Hays County. Find the peak discharge for the existing drainage basin and the drainage basin assuming future development in the zoned area. A 10-year design and 100- year check is required for the proposed culvert.
Transcript
Page 1: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

1of 39

Examples

Introduction

This appendix offers the following examples

diams Rational Method example problem

diams hyetograph example developed from NRCS 24-hour rainfall distributions

diams hyetograph example using the Balanced Storm Method

diams Muskingham Method

diams Standard Step Method

diams storm drain design

Rational Method Example Problem

Problem Statement Both a topographic map and field survey show the area of the drainagebasin upstream of a proposed highway culvert which is found to be 19 hectares (Figure F-1) In terms of soils and surface cover the existing drainage area is reasonablyhomogeneous with mostly light woodlands and brush There appear to be two distinct flowpaths converging in the lower area Local zoning allows light industry in an area adjacent tothe highway The combination of highway improvements and growth in the region make fulldevelopment of the zoned area attractive and likely within the next few years The drainagebasin is in Hays County Find the peak discharge for the existing drainage basin and thedrainage basin assuming future development in the zoned area A 10-year design and 100-year check is required for the proposed culvert

2of 39

Figure F-1 Drainage Areas for Rational Method Example Problem

Example of Rational MethodStep Action

Step 1 Determine drainage areas Step 2 Determine time of concentration Step 3 Ensure limitations of Rational Method have not been exceeded Step 4 Select coefficients for 10-year and 100-year flood frequencies for Hays

County Step 5 Calculate rainfall intensity using Equation 5-5 Step 6 Calculate composite runoff coefficient Step 7 Calculate peak discharges using Equation 5-7 and the table Runoff

Curve Numbers for Urban Areas

Step 1

Determine drainage areasbull Total Area = 19 habull Future developed area = 5 habull Future undeveloped area = 14 ha

Step 2

Determine time of concentration With reference to Figure F-1 two likely flow paths areACD and BCD

3of 39

a For existing conditions assume path AC is about 50 m of overland flow overpasture and 255 m of grassed waterway Using Figure 5-4 for a slope of 08 andpasture the velocity vAC1 is about 02 ms Similarly for grassed waterway thevelocity vAC2 is about 042 ms The time of travel over length AC is

t t tAC AC1 AC= + = + =2500 2

2550 42

60 14 3

min

b For existing conditions the path CD is a grassy channel with an estimated bank-to-bank average velocity vCDe of 07 ms For future conditions a lined channel isanticipated with an estimated average bank-full velocity vCDf of 1 msbull The associated times of travel are

t sCDe =times

=2130 7 60

51

min

and

t sCDf =times

=2131 0 60

3 6

min

bull The time of travel for ACD under existing conditions (tACDe) is

tACDe = 143 + 51 = 194 minbull The time of travel for ACD under future conditions (tACDf) is

tACDf = 143 + 36 = 179 minc Assume path BC is about 50 m of overland flow over pasture and 351 m grassy

swale Using Figure 5-4 for a slope of 06 and pasture the velocity vAC1 isabout 019 ms Similarly for grassed waterway the velocity vAC2 is about 035msbull The time of travel over length BC is

t t tBC BC1 BC= + = + =250

0193510 35

60 211

min

bull The time of travel for BCD under existing conditions (tACDe) is

tBCDe = 211 + 51 = 262 minbull The time of travel for BCD under future conditions (tACDf) is

tBCDe = 211 + 36 = 247 min

tBCDe gt tACDe

and

tBCDf gt tACDf

4of 39

d Under the assumptions of the Rational Method the longer travel time is taken asthe time of concentration Therefore for existing conditions the time ofconcentration Te is 262 minutes For future conditions the time of concentrationTf is 247 minutes

Step 3

Ensure limitations of the Rational Method have not been exceeded

Because the total drainage area is less than 80 ha no appreciable storage is indicated andthe watershed shape is not unusual the Rational Method may be used

Step 4

Select coefficients for the 10-year and 100-year flood frequencies for Hays County

Use Hydrology documentbull e10 = 0776 b10 = 1981 d10 = 86bull e100 = 0755 b100 = 2642 d100 = 82

Step 5

Calculate the rainfall intensity using Equation 5-5a For existing conditions

( ) ( )I b

t d1981

26 8612610

ce 0776=

+=

+=

2mmhr

( ) ( )I b

t d2642

26 82100

ce 0755=

+=

+=

2183mmhr

b For future conditions

( ) ( )I b

t d1981

247 8613110

ce 0776=

+=

+= mmhr

( ) ( )I b

t d2642

82100

ce 0755=

+=

+=

24 7189

mmhr

Step 6

Calculate composite runoff coefficienta For existing conditions the area is homogeneous with C = 025b For future conditions

5of 39

CC A C A

A A025(14) 06(5)

14 501 1 2 2

1 2

=++

= ++

= 34

Step 7

Calculate peak discharges using Equation 5-5 and the Runoff Curve Numbers for UrbanAreas

a For 10 year Cf = 10 For 100 year Cf = 125b For existing conditions

Q CIA360

(025)(126)(19) 360 166 m s103= = =

Q CC IA

360 (025)(125)(183)(19) 360 302 m s100

f 3= = =

c For future conditions

Q CIA360

(034)(131)(19) 360 235 m s103= = =

Q CC IA

360 (034)(125)(189)(19) 360 424 m s100

f 3= = =

Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions

The following is an example of a rainfall hyetograph for a 25-year 24-hour storm in HarrisCounty For demonstration only a one-hour time increment is used

Total precipitation (from Hydrology ) = 244 mm

Distribution type (from Figure 5-8) = III

The Rainfall Groups for Antecedent Soil Moisture Conditions During Growing andDormant Seasons presents the calculations Figure 5-11 shows the resulting hyetograph

For time = 1 hour

1 The cumulative fraction is determined by interpolation of the Runoff Curve Numbersfor Arid and Semi Arid Rangelands P1P24 = 0 +(002ndash0) times (1ndash0)(2-0) = 001

2 The cumulative rainfall is the product of the cumulative fraction and the total 24-hourrainfall P1 = 001 times 244 = 244 mm

3 The incremental rainfall is the difference between the current and preceding cumulativerainfall values 244ndash0 = 244 mm

Repeating the procedure for each time period yields the complete hyetograph ordinates

6of 39

Hyetograph Example Using the Balanced Storm Method

The following represents the development of a five-year three-hour duration rainfallhyetograph for Travis County The rainfall intensity coefficients are e = 078 b = 1753 d =86 (Appendix B) The duration is 3 hours = 180 minutes Using 15 minute intervals thetotal number of intervals is 18015 = 12 For a duration of 15 minutes

diams the intensity is 1753(15 + 86)078 = 14891 mmhour (using Equation 5-5 where theduration replaces time of concentration)

diams the cumulative depth is 14891 times 15 (min) 60 (min per hour) = 3723 mm

diams the incremental depth is 3723ndash0 = 3723 mm

Calculation of the values for each duration up to 180 minutes is similar The Example ofBalanced Storm table tabulates the calculations The highest incremental rainfall (always atthe shortest duration) is 3723 mm This is assigned the central time block of 75ndash90 minutesThe next highest 1350 is assigned to the 90ndash105 minute time block which is after thecentral block The next highest increment is 817 and is assigned to the 60ndash75 minute timeblock which immediately precedes the central time block This distribution continuesalternating between next available time blocks from the central block Figure F-2 shows theresulting hyetograph

7of 39

Example of Balanced Storm TabulationDuration

(min)Intensity(mmhr)

Cum Depth(mm)

Incr Depth(mm)

Time Block(mm)

Rainfall(mm)

15 14891 3723 3723 0-- 15 21230 10145 5072 1350 15-30 25645 7853 5890 817 30-45 32760 6478 6478 588 45-60 46275 5552 6940 462 60-75 81790 4882 7322 382 75-90 3723105 4371 7649 327 90-105 1350120 3968 7936 287 105-120 588135 3641 8192 256 120-135 382150 3369 8423 231 135-150 287165 3140 8635 212 150-165 231180 2943 8830 195 165-180 195

Figure F-2 Example of Hyetograph Using Balanced Storm Method

8of 39

Muskingum Method

The example shown in the Channel Routing Using the Muskingum Method table shows atriangular hydrograph routed through three 1000 meter reaches of channel The outflowhydrograph for each reach is used as the inflow for the next The channel has a lsquoKrsquo of 0278hours (1000 seconds) and an times of 02

Using Equations 5-30 5-31 and 5-32 with a time increment of 1000 sec

C11000 2 1000 0 2

2 1000 1 0 2 10000 23077= minus

minus +=( )( )

( )( )

C21000 2 1000 0 2

2 1000 1 0 2 1000053846= +

minus +=( )( )

( )( )

C32 1000 1 0 2 10002 1000 1 0 2 1000

0 23077= minus minusminus +

=( )( )( )( )

Check C1 + C2 + C3 = 023077 + 023077 + 053846 = 1

For time step two (t = 2) first reach

O2 = (023077)(200) + (053846)(0) + (023077)(0) = 4615 m3s

For time step 3 (t = 3)

O3 = (023077)(400) + (053846)(200) + (023077)(4615) = 21065 m3s

Repeating the process until the outflow hydrograph is complete The outflow hydrographfrom reach one becomes the inflow hydrograph for reach 2 and the process is repeated forreaches 2 and 3 Figure F-3 shows a plot of the hydrographs Since the outflow hydrographrepresents a displacement in distance as well as time the peak outflow does not coincidewith the receding limb of the inflow hydrograph

9of 39

Channel Routing Using the Muskingum MethodOutflow (m8s)Time

stepTime

(s)Inflow(m8s) Reach 1 Reach 2 Reach 3

1 0 0 0 0 02 1000 200 4615 1065 2463 2000 400 21065 7592 23824 3000 300 33323 20785 94345 4000 200 28459 29307 201326 5000 100 19644 26621 265707 6000 9918 19010 248528 7000 2289 10255 183389 8000 528 3721 1061310 9000 122 1171 472311 10000 028 3472 180012 11000 006 096 62213 12000 001 026 20114 13000 000 007 06215 14000 000 002 01816 15000 000 000 00517 16000 000 000 00218 17000 000 000 000

10of 39

Figure F-3 Plot of a Triangular Hydrograph Routed Through Three Segments of Channel

Standard Step Method

Four cross sections along a reach are shown in Figures 7-17 7-18 7-19 7-20 Each crosssection is separated by 1524 m and is subdivided according to geometry and roughnessThe calculations shown in WS Elevation of 235 m represent one set of water-surfacecalculations An explanation of WS Elevation of 235 m follows the calculations Thecalculations represent the results of iterations at each section

Column 1 This column contains the cross section identification name

Column 2 This column contains the stream cross section station number

Column 3 The assumed water surface elevation must agree with the resulting computedwater surface elevation within plusmn 005 meters (or some other allowable tolerance) fortrial calculations to be successful

Column 4 This is the stage-discharge (rating) curve value for the first section thereafter itis the value calculated by adding ∆WS (Column 21) to the computed water surfaceelevation for the previous cross section

11of 39

Column 5 A is the cross-sectional area If the section is complex and has been subdividedinto several parts (eg left overbank channel and right overbank) then use one line ofthe form for each subsection and add to get the total area of cross section (At)

Column 6 This column contains the wetted perimeter If the section is subdivided thenuse one line for each subsection wetted perimeter

Column 7 R is the hydraulic radius Use the same procedure as for Column 5 if the sectionis complex but do not add subsection values

Column 8 n is Manningrsquos coefficient of channel roughness

Column 9 K is the conveyance and is determined with Equation 6-4 This column containsthe total conveyance for the cross section If the cross section is complex addsubsection K values to get the total conveyance (Kt)

Column 10 Kave the average conveyance for the reach is computed with Equation F-1

( )K = 12

K + Kave ds us

Equation F-1

Column 11 This column contains the friction slope at the current section and is computedusing Equation 67ndash8

S QKf =

2

Equation F-2

Column 12 The average friction slope is determined using Equation F-3

S QKf ave =

ave

2

Equation F-3

Column 13 L is the distance between cross-sections

Column 14 The energy loss due to friction (hf) through the reach is calculated usingEquation F-4

h = S Lf aveEquation F-4

Column 15 This column contains part of the expression relating distributed flow velocitiesto an average value (see Column 16) If the section is complex calculate one of thesevalues for each subsection and add all subsection values to get a total If one

12of 39

subsection is used you do not need Column 15 and the kinetic energy coefficient(Column 16) equals 10

Column 16 The kinetic energy coefficient (α) is calculated with Equation 6-10

Column 17 The average velocity (V) for the cross section is calculated with the continuityequation (Equation 6-1)

Column 18 This column contains the average velocity head corrected for flowdistribution

Column 19 This column contains the difference between the downstream and upstreamvelocity heads A positive value indicates velocity is increasing therefore use acontraction coefficient to account for ldquoother lossesrdquo A negative value indicates theexpansion coefficient should be used in calculating ldquoother lossesrdquo

Column 20 Calculate the ldquoother lossesrdquo by multiplying either the expansion coefficient(Ke) or contraction coefficient (Kc) by the absolute value of Column 18 That is forexpansion the change in velocity head will be negative but the head loss must bepositive ∆WS is the change in water surface elevation from the previous cross sectionIt is the algebraic sum of Columns 14 19 and 20

Storm Drain Design

Problem Statement

Given The working schematic Figure F-4 shows the layout of the roadway and crossstreets to be drained At the node indicated as A8 on the schematic an outflow from asmall storm drain system within the indicated shopping mall is accepted into thedepartmentrsquos system The storm drain system will outfall into a channel which isdirectly downstream of a culvert as indicated The culvert accommodates flow from a9065 hectare watershed

13of 39

Figure F-4 Layout of Drainage Areas and Inlets

14of 39

The hydrology and inlet data for this example are given in Hydrology and Inlet Informationtable This table includes the following for each drainage area

diams area

diams time of concentration

diams gutter slope

diams reciprocal of the cross slope

Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

A1 Curb 069010

055085 75 24 00050

A2 SGrate 006 070 20 32B1 Slot 011 085 32 24

00050C1 Curb 078

014050085 145 32 00060

A3 SGrate 010 070 20 32D1 Slot 014 085 41 32 00060E1 Slot 022 050 50 48 00065E2 Curb 042

011055085 135 48 00060

A4 JuncG1 Curb 041

011050085 90 32 00060

A5 SGrate 005 070 20 32F1 Slot 009 085 36 32 00060H1 Curb 008

006055085 60 48 00030

H2 Curb 012022

055085 65 48 00050

15of 39

(continued) Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

I1 Slot 032007

055085 80 48 00030

K1 Grate 066013

040085 150 48 00040

J1 Scurb 043021

060085 88 32

L1 Grate 030007

055085 177 48 00040

L2 Grate 024 085 36 48 00040L3 Grate 017 085 30 48 00040A6 JuncM1 SCurb 033 085 42 32A7 SGrate 004 070 20 32N1 SCurb 041 085 70 32Offsite 018

149070085 116

A8 JuncA9 Sgrate 012 070 34 32A10 Outfall

The Conduit Information table presents conduit design information such as soffitelevations and pipe lengths The General Given Information table contains generalinformation including

diams rainfall intensity factors

diams allowable ponded widths and

diams inlet requirements

16of 39

Conduit InformationIdentificationsUS DS

Length (m) US Soffit Elev (m)

A1 A2 20 256760B1 A2 20 256730A2 A3 100 256670C1 A3 20 256260D1 A3 20 256270A3 A4 20 256200E1 E2 90 256600E2 A4 20 256150A4 A5 75 256090G1 A5 20 255810F1 A5 25 255830A5 A6 75 255730J1 G1 25 255940H1 H2 125 255880I1 H2 60 255810H2 A6 57 255560L1 L2 95 256320K1 L2 55 256070L2 L3 86 255850L3 A6 20 255570A6 A7 56 255490M1 A7 20 255300N1 A7 18 255240A7 A8 60 255220A8 A9 104 254880A9 A10 40 254270

17of 39

General Given InformationDesign Frequency 5 years (20 chance of exceedance)Rainfall intensity factors e = 078 b = 1422 mm d = 82Curb height 015 mMinimum time of concentration 10 minutesMinimum curb inlet length 15 mMinimum slotted drain inlet length 6 mStandard grate inlets Parallel bars wtransverse rods

W = 05 m and L = 1 mGrate inlets on sag in median 05 m x 05 m square inlets bar area =

25 of grate area allowable pondeddepth = 06 m

Gutter depression for curb inlets 75 mmAllowable ponded width 36 m on Lone Star Blvd and 45 m on

Texas AveCurb inlets on sag slope = 00050 mm and 50 of

discharge on each side of inletOutfall tailwater elevation (2 yr) 254360 m

Required Design a storm drain system to accommodate the design discharge

Discussion The following example represents a single iteration of the design process It isone of a series of iterations that would require revision re-analysis and optimizationuntil a technically acceptable and economical design is accomplished

In a production design all design parameters and criteria must be met The illustration ofthe hydraulic grade line is for demonstration only Typically the hydraulic grade line isdeveloped as a last design step after the system has been optimized The next subsectionsoffer initial design process components and a design iteration procedure

Initial Design Process Components

The initial design process consists basically of the following three components

diams hydrology

diams inlet design and

diams conduit design

These components will be addressed individually However it is important to understandthat all three components must function together simultaneously You must evaluate thehydrology aspects with respect to both inlet design and conduit design

18of 39

Design Iteration Procedure

The following steps illustrate the activities in a single design iteration

Design Iteration ProcedureStep Action

Step 1 Prepare a system planStep 2 Base initial runoff computations on Rational Method and tabulate them in

Conduit Information tableStep 3 Locate inlets based on logic and hydraulic demand and configure the conduit

system

Step 1

Prepare a system plan

Prepare a system plan as discussed in Section 2 System Planning Effectively the exampleproblem is identified as delineated in the problem statement Ensure there are no ldquodeadrdquospots where the runoff has no outlet Establish the general location of inlets the laterals andthe trunk lines You must coordinate the logical location of the various system componentswith the component locations necessary to satisfy hydraulic demand In subsequent designiterations you may change any or all parts of the system configuration as necessary

a Establish the design parameters and criteriab Select materials and shapes to be usedc Assign the design frequencyd Identify utility intersections with respect to

bull locationbull typebull owner and probable disposition

e Identify detention facilities

19of 39

Step 2

Base initial runoff computations on the Rational Method and tabulate them in ConduitInformation table The first four columns of this tabulation are self-explanatory The totalCA as shown in the fifth column is computed by multiplying each incremental area by itscorresponding coefficient of runoff and summing these incremental products As anexample the total CA for drainage area A1 is computed as follows

Type Hectares C CAPaved 010 x 085 = 0085Residential 069 x 055 = 0380TOTALS 079 0465

20of 39

Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

A1 Curb 069010

055085

0465 75 100 14793 0191

A2 SGrate 006 070 0042 20 100 14793 0017B1 Slot 011 085 0094 32 100 14793 0038C1 Curb 078

014050085 0509 145 145 12451 0176

A3 SGrate 010 070 0070 20 100 14793 0029D1 Slot 014 085 0119 41 100 14793 0049E1 Slot 022 050 0110 50 100 14793 0045E2 Curb 042

011055085 0325 135 135 12896 0116

A4 Junc 000 000G1 Curb 041

011050085 0299 90 100 14793 0123

A5 SGrate 005 070 0035 20 100 14793 0014F1 Slot 009 085 0077 36 100 14793 0031H1 Curb 008

006055085 0095 60 100 14793 0039

H2 Curb 012022

055085 0253 65 100 14793 0104

I1 Slot 032007

055085 0236 80 100 14793 0097

21of 39

(continued) Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

K1 Grate 066013

040085 0375 150 150 12241 0127

J1 SCurb 043021

060085 0437 88 100 14793 0180

L1 Grate 030007

055085 0225 177 177 11234 0070

L2 Grate 024 085 0204 36 100 14793 0084L3 Grate 017 085 0145 30 100 14793 0059A6 Junc 000 000M1 SCurb 033 085 0281 42 100 14793 0115A7 SGrate 004 070 0028 20 100 14793 0012N1 SCurb 041 085 0349 70 100 14793 0143Offsite 018

149070085 1393 116 116 13852 0536

A8 Junc 000 000A9 SGrate 012 070 0084 34 100 14793 0035A10 Outfall 000 000

a In the Summary of Hydrologic Computations table note that the operating timeof concentration has a minimum value of 10 minutes (according to departmentpractice) However it is necessary to account for the smaller time of concentrationtherefore the actual time of concentration (minimum notwithstanding) is alsotabulated

b The rainfall intensity (I) is based on Equation F-5 where e = 078 b = 1422 and d= 82 For drainage area A1 the time of concentration is only 75 minutesTherefore using 10 minutes as a basis the rainfall intensity is calculated as 1479mmhr

If =b

tc + d( )e

Equation F-5where

If=rainfall intensity for frequency (mmhr)tc=time of concentration (min)e b d= empirical factors which are tabulated for each county in Texas

for frequencies of 2 5 10 25 50 and 100 years in Appendix Bc The peak discharge (Q) is determined by multiplying CA by I and 000278

(Equation F-6)

Q = C I A360

22of 39

Equation F-6whereQ =peak discharge (m3s)C =runoff coefficientI =rainfall intensity associated with a specific frequency (mmhr)A =area of the watershed (ha)

d For watershed A1 Q is 0191 m3sStep 3

Locate the inlets based on logic and hydraulic demand and configure the conduit systema Locate the inlets based on logic and hydraulic demand as outlined in Section 5

Storm Drain Inletsb Finally after locating the inlets (establishing the nodes for the storm drain system)

you can configure the conduit system

Tables F-7 to F-13 show the suggested tabular format for calculations in the design of theinlet system in this example Since the design process is iterative requiring adjustments andre-analysis until the design is optimized the examples shown are only a ldquosnapshotrdquo (or oneiteration) during the design process

Inlets On-Grade Explanation

C = =

=

C A

A

n nn

m

nn

m1

1

Equation F-7where

C=weighted runoff coefficientn=nth subaream=number of subareasCn=runoff coefficient for nth subareaAn=nth subarea size (ha)

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 2: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

2of 39

Figure F-1 Drainage Areas for Rational Method Example Problem

Example of Rational MethodStep Action

Step 1 Determine drainage areas Step 2 Determine time of concentration Step 3 Ensure limitations of Rational Method have not been exceeded Step 4 Select coefficients for 10-year and 100-year flood frequencies for Hays

County Step 5 Calculate rainfall intensity using Equation 5-5 Step 6 Calculate composite runoff coefficient Step 7 Calculate peak discharges using Equation 5-7 and the table Runoff

Curve Numbers for Urban Areas

Step 1

Determine drainage areasbull Total Area = 19 habull Future developed area = 5 habull Future undeveloped area = 14 ha

Step 2

Determine time of concentration With reference to Figure F-1 two likely flow paths areACD and BCD

3of 39

a For existing conditions assume path AC is about 50 m of overland flow overpasture and 255 m of grassed waterway Using Figure 5-4 for a slope of 08 andpasture the velocity vAC1 is about 02 ms Similarly for grassed waterway thevelocity vAC2 is about 042 ms The time of travel over length AC is

t t tAC AC1 AC= + = + =2500 2

2550 42

60 14 3

min

b For existing conditions the path CD is a grassy channel with an estimated bank-to-bank average velocity vCDe of 07 ms For future conditions a lined channel isanticipated with an estimated average bank-full velocity vCDf of 1 msbull The associated times of travel are

t sCDe =times

=2130 7 60

51

min

and

t sCDf =times

=2131 0 60

3 6

min

bull The time of travel for ACD under existing conditions (tACDe) is

tACDe = 143 + 51 = 194 minbull The time of travel for ACD under future conditions (tACDf) is

tACDf = 143 + 36 = 179 minc Assume path BC is about 50 m of overland flow over pasture and 351 m grassy

swale Using Figure 5-4 for a slope of 06 and pasture the velocity vAC1 isabout 019 ms Similarly for grassed waterway the velocity vAC2 is about 035msbull The time of travel over length BC is

t t tBC BC1 BC= + = + =250

0193510 35

60 211

min

bull The time of travel for BCD under existing conditions (tACDe) is

tBCDe = 211 + 51 = 262 minbull The time of travel for BCD under future conditions (tACDf) is

tBCDe = 211 + 36 = 247 min

tBCDe gt tACDe

and

tBCDf gt tACDf

4of 39

d Under the assumptions of the Rational Method the longer travel time is taken asthe time of concentration Therefore for existing conditions the time ofconcentration Te is 262 minutes For future conditions the time of concentrationTf is 247 minutes

Step 3

Ensure limitations of the Rational Method have not been exceeded

Because the total drainage area is less than 80 ha no appreciable storage is indicated andthe watershed shape is not unusual the Rational Method may be used

Step 4

Select coefficients for the 10-year and 100-year flood frequencies for Hays County

Use Hydrology documentbull e10 = 0776 b10 = 1981 d10 = 86bull e100 = 0755 b100 = 2642 d100 = 82

Step 5

Calculate the rainfall intensity using Equation 5-5a For existing conditions

( ) ( )I b

t d1981

26 8612610

ce 0776=

+=

+=

2mmhr

( ) ( )I b

t d2642

26 82100

ce 0755=

+=

+=

2183mmhr

b For future conditions

( ) ( )I b

t d1981

247 8613110

ce 0776=

+=

+= mmhr

( ) ( )I b

t d2642

82100

ce 0755=

+=

+=

24 7189

mmhr

Step 6

Calculate composite runoff coefficienta For existing conditions the area is homogeneous with C = 025b For future conditions

5of 39

CC A C A

A A025(14) 06(5)

14 501 1 2 2

1 2

=++

= ++

= 34

Step 7

Calculate peak discharges using Equation 5-5 and the Runoff Curve Numbers for UrbanAreas

a For 10 year Cf = 10 For 100 year Cf = 125b For existing conditions

Q CIA360

(025)(126)(19) 360 166 m s103= = =

Q CC IA

360 (025)(125)(183)(19) 360 302 m s100

f 3= = =

c For future conditions

Q CIA360

(034)(131)(19) 360 235 m s103= = =

Q CC IA

360 (034)(125)(189)(19) 360 424 m s100

f 3= = =

Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions

The following is an example of a rainfall hyetograph for a 25-year 24-hour storm in HarrisCounty For demonstration only a one-hour time increment is used

Total precipitation (from Hydrology ) = 244 mm

Distribution type (from Figure 5-8) = III

The Rainfall Groups for Antecedent Soil Moisture Conditions During Growing andDormant Seasons presents the calculations Figure 5-11 shows the resulting hyetograph

For time = 1 hour

1 The cumulative fraction is determined by interpolation of the Runoff Curve Numbersfor Arid and Semi Arid Rangelands P1P24 = 0 +(002ndash0) times (1ndash0)(2-0) = 001

2 The cumulative rainfall is the product of the cumulative fraction and the total 24-hourrainfall P1 = 001 times 244 = 244 mm

3 The incremental rainfall is the difference between the current and preceding cumulativerainfall values 244ndash0 = 244 mm

Repeating the procedure for each time period yields the complete hyetograph ordinates

6of 39

Hyetograph Example Using the Balanced Storm Method

The following represents the development of a five-year three-hour duration rainfallhyetograph for Travis County The rainfall intensity coefficients are e = 078 b = 1753 d =86 (Appendix B) The duration is 3 hours = 180 minutes Using 15 minute intervals thetotal number of intervals is 18015 = 12 For a duration of 15 minutes

diams the intensity is 1753(15 + 86)078 = 14891 mmhour (using Equation 5-5 where theduration replaces time of concentration)

diams the cumulative depth is 14891 times 15 (min) 60 (min per hour) = 3723 mm

diams the incremental depth is 3723ndash0 = 3723 mm

Calculation of the values for each duration up to 180 minutes is similar The Example ofBalanced Storm table tabulates the calculations The highest incremental rainfall (always atthe shortest duration) is 3723 mm This is assigned the central time block of 75ndash90 minutesThe next highest 1350 is assigned to the 90ndash105 minute time block which is after thecentral block The next highest increment is 817 and is assigned to the 60ndash75 minute timeblock which immediately precedes the central time block This distribution continuesalternating between next available time blocks from the central block Figure F-2 shows theresulting hyetograph

7of 39

Example of Balanced Storm TabulationDuration

(min)Intensity(mmhr)

Cum Depth(mm)

Incr Depth(mm)

Time Block(mm)

Rainfall(mm)

15 14891 3723 3723 0-- 15 21230 10145 5072 1350 15-30 25645 7853 5890 817 30-45 32760 6478 6478 588 45-60 46275 5552 6940 462 60-75 81790 4882 7322 382 75-90 3723105 4371 7649 327 90-105 1350120 3968 7936 287 105-120 588135 3641 8192 256 120-135 382150 3369 8423 231 135-150 287165 3140 8635 212 150-165 231180 2943 8830 195 165-180 195

Figure F-2 Example of Hyetograph Using Balanced Storm Method

8of 39

Muskingum Method

The example shown in the Channel Routing Using the Muskingum Method table shows atriangular hydrograph routed through three 1000 meter reaches of channel The outflowhydrograph for each reach is used as the inflow for the next The channel has a lsquoKrsquo of 0278hours (1000 seconds) and an times of 02

Using Equations 5-30 5-31 and 5-32 with a time increment of 1000 sec

C11000 2 1000 0 2

2 1000 1 0 2 10000 23077= minus

minus +=( )( )

( )( )

C21000 2 1000 0 2

2 1000 1 0 2 1000053846= +

minus +=( )( )

( )( )

C32 1000 1 0 2 10002 1000 1 0 2 1000

0 23077= minus minusminus +

=( )( )( )( )

Check C1 + C2 + C3 = 023077 + 023077 + 053846 = 1

For time step two (t = 2) first reach

O2 = (023077)(200) + (053846)(0) + (023077)(0) = 4615 m3s

For time step 3 (t = 3)

O3 = (023077)(400) + (053846)(200) + (023077)(4615) = 21065 m3s

Repeating the process until the outflow hydrograph is complete The outflow hydrographfrom reach one becomes the inflow hydrograph for reach 2 and the process is repeated forreaches 2 and 3 Figure F-3 shows a plot of the hydrographs Since the outflow hydrographrepresents a displacement in distance as well as time the peak outflow does not coincidewith the receding limb of the inflow hydrograph

9of 39

Channel Routing Using the Muskingum MethodOutflow (m8s)Time

stepTime

(s)Inflow(m8s) Reach 1 Reach 2 Reach 3

1 0 0 0 0 02 1000 200 4615 1065 2463 2000 400 21065 7592 23824 3000 300 33323 20785 94345 4000 200 28459 29307 201326 5000 100 19644 26621 265707 6000 9918 19010 248528 7000 2289 10255 183389 8000 528 3721 1061310 9000 122 1171 472311 10000 028 3472 180012 11000 006 096 62213 12000 001 026 20114 13000 000 007 06215 14000 000 002 01816 15000 000 000 00517 16000 000 000 00218 17000 000 000 000

10of 39

Figure F-3 Plot of a Triangular Hydrograph Routed Through Three Segments of Channel

Standard Step Method

Four cross sections along a reach are shown in Figures 7-17 7-18 7-19 7-20 Each crosssection is separated by 1524 m and is subdivided according to geometry and roughnessThe calculations shown in WS Elevation of 235 m represent one set of water-surfacecalculations An explanation of WS Elevation of 235 m follows the calculations Thecalculations represent the results of iterations at each section

Column 1 This column contains the cross section identification name

Column 2 This column contains the stream cross section station number

Column 3 The assumed water surface elevation must agree with the resulting computedwater surface elevation within plusmn 005 meters (or some other allowable tolerance) fortrial calculations to be successful

Column 4 This is the stage-discharge (rating) curve value for the first section thereafter itis the value calculated by adding ∆WS (Column 21) to the computed water surfaceelevation for the previous cross section

11of 39

Column 5 A is the cross-sectional area If the section is complex and has been subdividedinto several parts (eg left overbank channel and right overbank) then use one line ofthe form for each subsection and add to get the total area of cross section (At)

Column 6 This column contains the wetted perimeter If the section is subdivided thenuse one line for each subsection wetted perimeter

Column 7 R is the hydraulic radius Use the same procedure as for Column 5 if the sectionis complex but do not add subsection values

Column 8 n is Manningrsquos coefficient of channel roughness

Column 9 K is the conveyance and is determined with Equation 6-4 This column containsthe total conveyance for the cross section If the cross section is complex addsubsection K values to get the total conveyance (Kt)

Column 10 Kave the average conveyance for the reach is computed with Equation F-1

( )K = 12

K + Kave ds us

Equation F-1

Column 11 This column contains the friction slope at the current section and is computedusing Equation 67ndash8

S QKf =

2

Equation F-2

Column 12 The average friction slope is determined using Equation F-3

S QKf ave =

ave

2

Equation F-3

Column 13 L is the distance between cross-sections

Column 14 The energy loss due to friction (hf) through the reach is calculated usingEquation F-4

h = S Lf aveEquation F-4

Column 15 This column contains part of the expression relating distributed flow velocitiesto an average value (see Column 16) If the section is complex calculate one of thesevalues for each subsection and add all subsection values to get a total If one

12of 39

subsection is used you do not need Column 15 and the kinetic energy coefficient(Column 16) equals 10

Column 16 The kinetic energy coefficient (α) is calculated with Equation 6-10

Column 17 The average velocity (V) for the cross section is calculated with the continuityequation (Equation 6-1)

Column 18 This column contains the average velocity head corrected for flowdistribution

Column 19 This column contains the difference between the downstream and upstreamvelocity heads A positive value indicates velocity is increasing therefore use acontraction coefficient to account for ldquoother lossesrdquo A negative value indicates theexpansion coefficient should be used in calculating ldquoother lossesrdquo

Column 20 Calculate the ldquoother lossesrdquo by multiplying either the expansion coefficient(Ke) or contraction coefficient (Kc) by the absolute value of Column 18 That is forexpansion the change in velocity head will be negative but the head loss must bepositive ∆WS is the change in water surface elevation from the previous cross sectionIt is the algebraic sum of Columns 14 19 and 20

Storm Drain Design

Problem Statement

Given The working schematic Figure F-4 shows the layout of the roadway and crossstreets to be drained At the node indicated as A8 on the schematic an outflow from asmall storm drain system within the indicated shopping mall is accepted into thedepartmentrsquos system The storm drain system will outfall into a channel which isdirectly downstream of a culvert as indicated The culvert accommodates flow from a9065 hectare watershed

13of 39

Figure F-4 Layout of Drainage Areas and Inlets

14of 39

The hydrology and inlet data for this example are given in Hydrology and Inlet Informationtable This table includes the following for each drainage area

diams area

diams time of concentration

diams gutter slope

diams reciprocal of the cross slope

Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

A1 Curb 069010

055085 75 24 00050

A2 SGrate 006 070 20 32B1 Slot 011 085 32 24

00050C1 Curb 078

014050085 145 32 00060

A3 SGrate 010 070 20 32D1 Slot 014 085 41 32 00060E1 Slot 022 050 50 48 00065E2 Curb 042

011055085 135 48 00060

A4 JuncG1 Curb 041

011050085 90 32 00060

A5 SGrate 005 070 20 32F1 Slot 009 085 36 32 00060H1 Curb 008

006055085 60 48 00030

H2 Curb 012022

055085 65 48 00050

15of 39

(continued) Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

I1 Slot 032007

055085 80 48 00030

K1 Grate 066013

040085 150 48 00040

J1 Scurb 043021

060085 88 32

L1 Grate 030007

055085 177 48 00040

L2 Grate 024 085 36 48 00040L3 Grate 017 085 30 48 00040A6 JuncM1 SCurb 033 085 42 32A7 SGrate 004 070 20 32N1 SCurb 041 085 70 32Offsite 018

149070085 116

A8 JuncA9 Sgrate 012 070 34 32A10 Outfall

The Conduit Information table presents conduit design information such as soffitelevations and pipe lengths The General Given Information table contains generalinformation including

diams rainfall intensity factors

diams allowable ponded widths and

diams inlet requirements

16of 39

Conduit InformationIdentificationsUS DS

Length (m) US Soffit Elev (m)

A1 A2 20 256760B1 A2 20 256730A2 A3 100 256670C1 A3 20 256260D1 A3 20 256270A3 A4 20 256200E1 E2 90 256600E2 A4 20 256150A4 A5 75 256090G1 A5 20 255810F1 A5 25 255830A5 A6 75 255730J1 G1 25 255940H1 H2 125 255880I1 H2 60 255810H2 A6 57 255560L1 L2 95 256320K1 L2 55 256070L2 L3 86 255850L3 A6 20 255570A6 A7 56 255490M1 A7 20 255300N1 A7 18 255240A7 A8 60 255220A8 A9 104 254880A9 A10 40 254270

17of 39

General Given InformationDesign Frequency 5 years (20 chance of exceedance)Rainfall intensity factors e = 078 b = 1422 mm d = 82Curb height 015 mMinimum time of concentration 10 minutesMinimum curb inlet length 15 mMinimum slotted drain inlet length 6 mStandard grate inlets Parallel bars wtransverse rods

W = 05 m and L = 1 mGrate inlets on sag in median 05 m x 05 m square inlets bar area =

25 of grate area allowable pondeddepth = 06 m

Gutter depression for curb inlets 75 mmAllowable ponded width 36 m on Lone Star Blvd and 45 m on

Texas AveCurb inlets on sag slope = 00050 mm and 50 of

discharge on each side of inletOutfall tailwater elevation (2 yr) 254360 m

Required Design a storm drain system to accommodate the design discharge

Discussion The following example represents a single iteration of the design process It isone of a series of iterations that would require revision re-analysis and optimizationuntil a technically acceptable and economical design is accomplished

In a production design all design parameters and criteria must be met The illustration ofthe hydraulic grade line is for demonstration only Typically the hydraulic grade line isdeveloped as a last design step after the system has been optimized The next subsectionsoffer initial design process components and a design iteration procedure

Initial Design Process Components

The initial design process consists basically of the following three components

diams hydrology

diams inlet design and

diams conduit design

These components will be addressed individually However it is important to understandthat all three components must function together simultaneously You must evaluate thehydrology aspects with respect to both inlet design and conduit design

18of 39

Design Iteration Procedure

The following steps illustrate the activities in a single design iteration

Design Iteration ProcedureStep Action

Step 1 Prepare a system planStep 2 Base initial runoff computations on Rational Method and tabulate them in

Conduit Information tableStep 3 Locate inlets based on logic and hydraulic demand and configure the conduit

system

Step 1

Prepare a system plan

Prepare a system plan as discussed in Section 2 System Planning Effectively the exampleproblem is identified as delineated in the problem statement Ensure there are no ldquodeadrdquospots where the runoff has no outlet Establish the general location of inlets the laterals andthe trunk lines You must coordinate the logical location of the various system componentswith the component locations necessary to satisfy hydraulic demand In subsequent designiterations you may change any or all parts of the system configuration as necessary

a Establish the design parameters and criteriab Select materials and shapes to be usedc Assign the design frequencyd Identify utility intersections with respect to

bull locationbull typebull owner and probable disposition

e Identify detention facilities

19of 39

Step 2

Base initial runoff computations on the Rational Method and tabulate them in ConduitInformation table The first four columns of this tabulation are self-explanatory The totalCA as shown in the fifth column is computed by multiplying each incremental area by itscorresponding coefficient of runoff and summing these incremental products As anexample the total CA for drainage area A1 is computed as follows

Type Hectares C CAPaved 010 x 085 = 0085Residential 069 x 055 = 0380TOTALS 079 0465

20of 39

Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

A1 Curb 069010

055085

0465 75 100 14793 0191

A2 SGrate 006 070 0042 20 100 14793 0017B1 Slot 011 085 0094 32 100 14793 0038C1 Curb 078

014050085 0509 145 145 12451 0176

A3 SGrate 010 070 0070 20 100 14793 0029D1 Slot 014 085 0119 41 100 14793 0049E1 Slot 022 050 0110 50 100 14793 0045E2 Curb 042

011055085 0325 135 135 12896 0116

A4 Junc 000 000G1 Curb 041

011050085 0299 90 100 14793 0123

A5 SGrate 005 070 0035 20 100 14793 0014F1 Slot 009 085 0077 36 100 14793 0031H1 Curb 008

006055085 0095 60 100 14793 0039

H2 Curb 012022

055085 0253 65 100 14793 0104

I1 Slot 032007

055085 0236 80 100 14793 0097

21of 39

(continued) Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

K1 Grate 066013

040085 0375 150 150 12241 0127

J1 SCurb 043021

060085 0437 88 100 14793 0180

L1 Grate 030007

055085 0225 177 177 11234 0070

L2 Grate 024 085 0204 36 100 14793 0084L3 Grate 017 085 0145 30 100 14793 0059A6 Junc 000 000M1 SCurb 033 085 0281 42 100 14793 0115A7 SGrate 004 070 0028 20 100 14793 0012N1 SCurb 041 085 0349 70 100 14793 0143Offsite 018

149070085 1393 116 116 13852 0536

A8 Junc 000 000A9 SGrate 012 070 0084 34 100 14793 0035A10 Outfall 000 000

a In the Summary of Hydrologic Computations table note that the operating timeof concentration has a minimum value of 10 minutes (according to departmentpractice) However it is necessary to account for the smaller time of concentrationtherefore the actual time of concentration (minimum notwithstanding) is alsotabulated

b The rainfall intensity (I) is based on Equation F-5 where e = 078 b = 1422 and d= 82 For drainage area A1 the time of concentration is only 75 minutesTherefore using 10 minutes as a basis the rainfall intensity is calculated as 1479mmhr

If =b

tc + d( )e

Equation F-5where

If=rainfall intensity for frequency (mmhr)tc=time of concentration (min)e b d= empirical factors which are tabulated for each county in Texas

for frequencies of 2 5 10 25 50 and 100 years in Appendix Bc The peak discharge (Q) is determined by multiplying CA by I and 000278

(Equation F-6)

Q = C I A360

22of 39

Equation F-6whereQ =peak discharge (m3s)C =runoff coefficientI =rainfall intensity associated with a specific frequency (mmhr)A =area of the watershed (ha)

d For watershed A1 Q is 0191 m3sStep 3

Locate the inlets based on logic and hydraulic demand and configure the conduit systema Locate the inlets based on logic and hydraulic demand as outlined in Section 5

Storm Drain Inletsb Finally after locating the inlets (establishing the nodes for the storm drain system)

you can configure the conduit system

Tables F-7 to F-13 show the suggested tabular format for calculations in the design of theinlet system in this example Since the design process is iterative requiring adjustments andre-analysis until the design is optimized the examples shown are only a ldquosnapshotrdquo (or oneiteration) during the design process

Inlets On-Grade Explanation

C = =

=

C A

A

n nn

m

nn

m1

1

Equation F-7where

C=weighted runoff coefficientn=nth subaream=number of subareasCn=runoff coefficient for nth subareaAn=nth subarea size (ha)

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 3: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

3of 39

a For existing conditions assume path AC is about 50 m of overland flow overpasture and 255 m of grassed waterway Using Figure 5-4 for a slope of 08 andpasture the velocity vAC1 is about 02 ms Similarly for grassed waterway thevelocity vAC2 is about 042 ms The time of travel over length AC is

t t tAC AC1 AC= + = + =2500 2

2550 42

60 14 3

min

b For existing conditions the path CD is a grassy channel with an estimated bank-to-bank average velocity vCDe of 07 ms For future conditions a lined channel isanticipated with an estimated average bank-full velocity vCDf of 1 msbull The associated times of travel are

t sCDe =times

=2130 7 60

51

min

and

t sCDf =times

=2131 0 60

3 6

min

bull The time of travel for ACD under existing conditions (tACDe) is

tACDe = 143 + 51 = 194 minbull The time of travel for ACD under future conditions (tACDf) is

tACDf = 143 + 36 = 179 minc Assume path BC is about 50 m of overland flow over pasture and 351 m grassy

swale Using Figure 5-4 for a slope of 06 and pasture the velocity vAC1 isabout 019 ms Similarly for grassed waterway the velocity vAC2 is about 035msbull The time of travel over length BC is

t t tBC BC1 BC= + = + =250

0193510 35

60 211

min

bull The time of travel for BCD under existing conditions (tACDe) is

tBCDe = 211 + 51 = 262 minbull The time of travel for BCD under future conditions (tACDf) is

tBCDe = 211 + 36 = 247 min

tBCDe gt tACDe

and

tBCDf gt tACDf

4of 39

d Under the assumptions of the Rational Method the longer travel time is taken asthe time of concentration Therefore for existing conditions the time ofconcentration Te is 262 minutes For future conditions the time of concentrationTf is 247 minutes

Step 3

Ensure limitations of the Rational Method have not been exceeded

Because the total drainage area is less than 80 ha no appreciable storage is indicated andthe watershed shape is not unusual the Rational Method may be used

Step 4

Select coefficients for the 10-year and 100-year flood frequencies for Hays County

Use Hydrology documentbull e10 = 0776 b10 = 1981 d10 = 86bull e100 = 0755 b100 = 2642 d100 = 82

Step 5

Calculate the rainfall intensity using Equation 5-5a For existing conditions

( ) ( )I b

t d1981

26 8612610

ce 0776=

+=

+=

2mmhr

( ) ( )I b

t d2642

26 82100

ce 0755=

+=

+=

2183mmhr

b For future conditions

( ) ( )I b

t d1981

247 8613110

ce 0776=

+=

+= mmhr

( ) ( )I b

t d2642

82100

ce 0755=

+=

+=

24 7189

mmhr

Step 6

Calculate composite runoff coefficienta For existing conditions the area is homogeneous with C = 025b For future conditions

5of 39

CC A C A

A A025(14) 06(5)

14 501 1 2 2

1 2

=++

= ++

= 34

Step 7

Calculate peak discharges using Equation 5-5 and the Runoff Curve Numbers for UrbanAreas

a For 10 year Cf = 10 For 100 year Cf = 125b For existing conditions

Q CIA360

(025)(126)(19) 360 166 m s103= = =

Q CC IA

360 (025)(125)(183)(19) 360 302 m s100

f 3= = =

c For future conditions

Q CIA360

(034)(131)(19) 360 235 m s103= = =

Q CC IA

360 (034)(125)(189)(19) 360 424 m s100

f 3= = =

Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions

The following is an example of a rainfall hyetograph for a 25-year 24-hour storm in HarrisCounty For demonstration only a one-hour time increment is used

Total precipitation (from Hydrology ) = 244 mm

Distribution type (from Figure 5-8) = III

The Rainfall Groups for Antecedent Soil Moisture Conditions During Growing andDormant Seasons presents the calculations Figure 5-11 shows the resulting hyetograph

For time = 1 hour

1 The cumulative fraction is determined by interpolation of the Runoff Curve Numbersfor Arid and Semi Arid Rangelands P1P24 = 0 +(002ndash0) times (1ndash0)(2-0) = 001

2 The cumulative rainfall is the product of the cumulative fraction and the total 24-hourrainfall P1 = 001 times 244 = 244 mm

3 The incremental rainfall is the difference between the current and preceding cumulativerainfall values 244ndash0 = 244 mm

Repeating the procedure for each time period yields the complete hyetograph ordinates

6of 39

Hyetograph Example Using the Balanced Storm Method

The following represents the development of a five-year three-hour duration rainfallhyetograph for Travis County The rainfall intensity coefficients are e = 078 b = 1753 d =86 (Appendix B) The duration is 3 hours = 180 minutes Using 15 minute intervals thetotal number of intervals is 18015 = 12 For a duration of 15 minutes

diams the intensity is 1753(15 + 86)078 = 14891 mmhour (using Equation 5-5 where theduration replaces time of concentration)

diams the cumulative depth is 14891 times 15 (min) 60 (min per hour) = 3723 mm

diams the incremental depth is 3723ndash0 = 3723 mm

Calculation of the values for each duration up to 180 minutes is similar The Example ofBalanced Storm table tabulates the calculations The highest incremental rainfall (always atthe shortest duration) is 3723 mm This is assigned the central time block of 75ndash90 minutesThe next highest 1350 is assigned to the 90ndash105 minute time block which is after thecentral block The next highest increment is 817 and is assigned to the 60ndash75 minute timeblock which immediately precedes the central time block This distribution continuesalternating between next available time blocks from the central block Figure F-2 shows theresulting hyetograph

7of 39

Example of Balanced Storm TabulationDuration

(min)Intensity(mmhr)

Cum Depth(mm)

Incr Depth(mm)

Time Block(mm)

Rainfall(mm)

15 14891 3723 3723 0-- 15 21230 10145 5072 1350 15-30 25645 7853 5890 817 30-45 32760 6478 6478 588 45-60 46275 5552 6940 462 60-75 81790 4882 7322 382 75-90 3723105 4371 7649 327 90-105 1350120 3968 7936 287 105-120 588135 3641 8192 256 120-135 382150 3369 8423 231 135-150 287165 3140 8635 212 150-165 231180 2943 8830 195 165-180 195

Figure F-2 Example of Hyetograph Using Balanced Storm Method

8of 39

Muskingum Method

The example shown in the Channel Routing Using the Muskingum Method table shows atriangular hydrograph routed through three 1000 meter reaches of channel The outflowhydrograph for each reach is used as the inflow for the next The channel has a lsquoKrsquo of 0278hours (1000 seconds) and an times of 02

Using Equations 5-30 5-31 and 5-32 with a time increment of 1000 sec

C11000 2 1000 0 2

2 1000 1 0 2 10000 23077= minus

minus +=( )( )

( )( )

C21000 2 1000 0 2

2 1000 1 0 2 1000053846= +

minus +=( )( )

( )( )

C32 1000 1 0 2 10002 1000 1 0 2 1000

0 23077= minus minusminus +

=( )( )( )( )

Check C1 + C2 + C3 = 023077 + 023077 + 053846 = 1

For time step two (t = 2) first reach

O2 = (023077)(200) + (053846)(0) + (023077)(0) = 4615 m3s

For time step 3 (t = 3)

O3 = (023077)(400) + (053846)(200) + (023077)(4615) = 21065 m3s

Repeating the process until the outflow hydrograph is complete The outflow hydrographfrom reach one becomes the inflow hydrograph for reach 2 and the process is repeated forreaches 2 and 3 Figure F-3 shows a plot of the hydrographs Since the outflow hydrographrepresents a displacement in distance as well as time the peak outflow does not coincidewith the receding limb of the inflow hydrograph

9of 39

Channel Routing Using the Muskingum MethodOutflow (m8s)Time

stepTime

(s)Inflow(m8s) Reach 1 Reach 2 Reach 3

1 0 0 0 0 02 1000 200 4615 1065 2463 2000 400 21065 7592 23824 3000 300 33323 20785 94345 4000 200 28459 29307 201326 5000 100 19644 26621 265707 6000 9918 19010 248528 7000 2289 10255 183389 8000 528 3721 1061310 9000 122 1171 472311 10000 028 3472 180012 11000 006 096 62213 12000 001 026 20114 13000 000 007 06215 14000 000 002 01816 15000 000 000 00517 16000 000 000 00218 17000 000 000 000

10of 39

Figure F-3 Plot of a Triangular Hydrograph Routed Through Three Segments of Channel

Standard Step Method

Four cross sections along a reach are shown in Figures 7-17 7-18 7-19 7-20 Each crosssection is separated by 1524 m and is subdivided according to geometry and roughnessThe calculations shown in WS Elevation of 235 m represent one set of water-surfacecalculations An explanation of WS Elevation of 235 m follows the calculations Thecalculations represent the results of iterations at each section

Column 1 This column contains the cross section identification name

Column 2 This column contains the stream cross section station number

Column 3 The assumed water surface elevation must agree with the resulting computedwater surface elevation within plusmn 005 meters (or some other allowable tolerance) fortrial calculations to be successful

Column 4 This is the stage-discharge (rating) curve value for the first section thereafter itis the value calculated by adding ∆WS (Column 21) to the computed water surfaceelevation for the previous cross section

11of 39

Column 5 A is the cross-sectional area If the section is complex and has been subdividedinto several parts (eg left overbank channel and right overbank) then use one line ofthe form for each subsection and add to get the total area of cross section (At)

Column 6 This column contains the wetted perimeter If the section is subdivided thenuse one line for each subsection wetted perimeter

Column 7 R is the hydraulic radius Use the same procedure as for Column 5 if the sectionis complex but do not add subsection values

Column 8 n is Manningrsquos coefficient of channel roughness

Column 9 K is the conveyance and is determined with Equation 6-4 This column containsthe total conveyance for the cross section If the cross section is complex addsubsection K values to get the total conveyance (Kt)

Column 10 Kave the average conveyance for the reach is computed with Equation F-1

( )K = 12

K + Kave ds us

Equation F-1

Column 11 This column contains the friction slope at the current section and is computedusing Equation 67ndash8

S QKf =

2

Equation F-2

Column 12 The average friction slope is determined using Equation F-3

S QKf ave =

ave

2

Equation F-3

Column 13 L is the distance between cross-sections

Column 14 The energy loss due to friction (hf) through the reach is calculated usingEquation F-4

h = S Lf aveEquation F-4

Column 15 This column contains part of the expression relating distributed flow velocitiesto an average value (see Column 16) If the section is complex calculate one of thesevalues for each subsection and add all subsection values to get a total If one

12of 39

subsection is used you do not need Column 15 and the kinetic energy coefficient(Column 16) equals 10

Column 16 The kinetic energy coefficient (α) is calculated with Equation 6-10

Column 17 The average velocity (V) for the cross section is calculated with the continuityequation (Equation 6-1)

Column 18 This column contains the average velocity head corrected for flowdistribution

Column 19 This column contains the difference between the downstream and upstreamvelocity heads A positive value indicates velocity is increasing therefore use acontraction coefficient to account for ldquoother lossesrdquo A negative value indicates theexpansion coefficient should be used in calculating ldquoother lossesrdquo

Column 20 Calculate the ldquoother lossesrdquo by multiplying either the expansion coefficient(Ke) or contraction coefficient (Kc) by the absolute value of Column 18 That is forexpansion the change in velocity head will be negative but the head loss must bepositive ∆WS is the change in water surface elevation from the previous cross sectionIt is the algebraic sum of Columns 14 19 and 20

Storm Drain Design

Problem Statement

Given The working schematic Figure F-4 shows the layout of the roadway and crossstreets to be drained At the node indicated as A8 on the schematic an outflow from asmall storm drain system within the indicated shopping mall is accepted into thedepartmentrsquos system The storm drain system will outfall into a channel which isdirectly downstream of a culvert as indicated The culvert accommodates flow from a9065 hectare watershed

13of 39

Figure F-4 Layout of Drainage Areas and Inlets

14of 39

The hydrology and inlet data for this example are given in Hydrology and Inlet Informationtable This table includes the following for each drainage area

diams area

diams time of concentration

diams gutter slope

diams reciprocal of the cross slope

Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

A1 Curb 069010

055085 75 24 00050

A2 SGrate 006 070 20 32B1 Slot 011 085 32 24

00050C1 Curb 078

014050085 145 32 00060

A3 SGrate 010 070 20 32D1 Slot 014 085 41 32 00060E1 Slot 022 050 50 48 00065E2 Curb 042

011055085 135 48 00060

A4 JuncG1 Curb 041

011050085 90 32 00060

A5 SGrate 005 070 20 32F1 Slot 009 085 36 32 00060H1 Curb 008

006055085 60 48 00030

H2 Curb 012022

055085 65 48 00050

15of 39

(continued) Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

I1 Slot 032007

055085 80 48 00030

K1 Grate 066013

040085 150 48 00040

J1 Scurb 043021

060085 88 32

L1 Grate 030007

055085 177 48 00040

L2 Grate 024 085 36 48 00040L3 Grate 017 085 30 48 00040A6 JuncM1 SCurb 033 085 42 32A7 SGrate 004 070 20 32N1 SCurb 041 085 70 32Offsite 018

149070085 116

A8 JuncA9 Sgrate 012 070 34 32A10 Outfall

The Conduit Information table presents conduit design information such as soffitelevations and pipe lengths The General Given Information table contains generalinformation including

diams rainfall intensity factors

diams allowable ponded widths and

diams inlet requirements

16of 39

Conduit InformationIdentificationsUS DS

Length (m) US Soffit Elev (m)

A1 A2 20 256760B1 A2 20 256730A2 A3 100 256670C1 A3 20 256260D1 A3 20 256270A3 A4 20 256200E1 E2 90 256600E2 A4 20 256150A4 A5 75 256090G1 A5 20 255810F1 A5 25 255830A5 A6 75 255730J1 G1 25 255940H1 H2 125 255880I1 H2 60 255810H2 A6 57 255560L1 L2 95 256320K1 L2 55 256070L2 L3 86 255850L3 A6 20 255570A6 A7 56 255490M1 A7 20 255300N1 A7 18 255240A7 A8 60 255220A8 A9 104 254880A9 A10 40 254270

17of 39

General Given InformationDesign Frequency 5 years (20 chance of exceedance)Rainfall intensity factors e = 078 b = 1422 mm d = 82Curb height 015 mMinimum time of concentration 10 minutesMinimum curb inlet length 15 mMinimum slotted drain inlet length 6 mStandard grate inlets Parallel bars wtransverse rods

W = 05 m and L = 1 mGrate inlets on sag in median 05 m x 05 m square inlets bar area =

25 of grate area allowable pondeddepth = 06 m

Gutter depression for curb inlets 75 mmAllowable ponded width 36 m on Lone Star Blvd and 45 m on

Texas AveCurb inlets on sag slope = 00050 mm and 50 of

discharge on each side of inletOutfall tailwater elevation (2 yr) 254360 m

Required Design a storm drain system to accommodate the design discharge

Discussion The following example represents a single iteration of the design process It isone of a series of iterations that would require revision re-analysis and optimizationuntil a technically acceptable and economical design is accomplished

In a production design all design parameters and criteria must be met The illustration ofthe hydraulic grade line is for demonstration only Typically the hydraulic grade line isdeveloped as a last design step after the system has been optimized The next subsectionsoffer initial design process components and a design iteration procedure

Initial Design Process Components

The initial design process consists basically of the following three components

diams hydrology

diams inlet design and

diams conduit design

These components will be addressed individually However it is important to understandthat all three components must function together simultaneously You must evaluate thehydrology aspects with respect to both inlet design and conduit design

18of 39

Design Iteration Procedure

The following steps illustrate the activities in a single design iteration

Design Iteration ProcedureStep Action

Step 1 Prepare a system planStep 2 Base initial runoff computations on Rational Method and tabulate them in

Conduit Information tableStep 3 Locate inlets based on logic and hydraulic demand and configure the conduit

system

Step 1

Prepare a system plan

Prepare a system plan as discussed in Section 2 System Planning Effectively the exampleproblem is identified as delineated in the problem statement Ensure there are no ldquodeadrdquospots where the runoff has no outlet Establish the general location of inlets the laterals andthe trunk lines You must coordinate the logical location of the various system componentswith the component locations necessary to satisfy hydraulic demand In subsequent designiterations you may change any or all parts of the system configuration as necessary

a Establish the design parameters and criteriab Select materials and shapes to be usedc Assign the design frequencyd Identify utility intersections with respect to

bull locationbull typebull owner and probable disposition

e Identify detention facilities

19of 39

Step 2

Base initial runoff computations on the Rational Method and tabulate them in ConduitInformation table The first four columns of this tabulation are self-explanatory The totalCA as shown in the fifth column is computed by multiplying each incremental area by itscorresponding coefficient of runoff and summing these incremental products As anexample the total CA for drainage area A1 is computed as follows

Type Hectares C CAPaved 010 x 085 = 0085Residential 069 x 055 = 0380TOTALS 079 0465

20of 39

Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

A1 Curb 069010

055085

0465 75 100 14793 0191

A2 SGrate 006 070 0042 20 100 14793 0017B1 Slot 011 085 0094 32 100 14793 0038C1 Curb 078

014050085 0509 145 145 12451 0176

A3 SGrate 010 070 0070 20 100 14793 0029D1 Slot 014 085 0119 41 100 14793 0049E1 Slot 022 050 0110 50 100 14793 0045E2 Curb 042

011055085 0325 135 135 12896 0116

A4 Junc 000 000G1 Curb 041

011050085 0299 90 100 14793 0123

A5 SGrate 005 070 0035 20 100 14793 0014F1 Slot 009 085 0077 36 100 14793 0031H1 Curb 008

006055085 0095 60 100 14793 0039

H2 Curb 012022

055085 0253 65 100 14793 0104

I1 Slot 032007

055085 0236 80 100 14793 0097

21of 39

(continued) Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

K1 Grate 066013

040085 0375 150 150 12241 0127

J1 SCurb 043021

060085 0437 88 100 14793 0180

L1 Grate 030007

055085 0225 177 177 11234 0070

L2 Grate 024 085 0204 36 100 14793 0084L3 Grate 017 085 0145 30 100 14793 0059A6 Junc 000 000M1 SCurb 033 085 0281 42 100 14793 0115A7 SGrate 004 070 0028 20 100 14793 0012N1 SCurb 041 085 0349 70 100 14793 0143Offsite 018

149070085 1393 116 116 13852 0536

A8 Junc 000 000A9 SGrate 012 070 0084 34 100 14793 0035A10 Outfall 000 000

a In the Summary of Hydrologic Computations table note that the operating timeof concentration has a minimum value of 10 minutes (according to departmentpractice) However it is necessary to account for the smaller time of concentrationtherefore the actual time of concentration (minimum notwithstanding) is alsotabulated

b The rainfall intensity (I) is based on Equation F-5 where e = 078 b = 1422 and d= 82 For drainage area A1 the time of concentration is only 75 minutesTherefore using 10 minutes as a basis the rainfall intensity is calculated as 1479mmhr

If =b

tc + d( )e

Equation F-5where

If=rainfall intensity for frequency (mmhr)tc=time of concentration (min)e b d= empirical factors which are tabulated for each county in Texas

for frequencies of 2 5 10 25 50 and 100 years in Appendix Bc The peak discharge (Q) is determined by multiplying CA by I and 000278

(Equation F-6)

Q = C I A360

22of 39

Equation F-6whereQ =peak discharge (m3s)C =runoff coefficientI =rainfall intensity associated with a specific frequency (mmhr)A =area of the watershed (ha)

d For watershed A1 Q is 0191 m3sStep 3

Locate the inlets based on logic and hydraulic demand and configure the conduit systema Locate the inlets based on logic and hydraulic demand as outlined in Section 5

Storm Drain Inletsb Finally after locating the inlets (establishing the nodes for the storm drain system)

you can configure the conduit system

Tables F-7 to F-13 show the suggested tabular format for calculations in the design of theinlet system in this example Since the design process is iterative requiring adjustments andre-analysis until the design is optimized the examples shown are only a ldquosnapshotrdquo (or oneiteration) during the design process

Inlets On-Grade Explanation

C = =

=

C A

A

n nn

m

nn

m1

1

Equation F-7where

C=weighted runoff coefficientn=nth subaream=number of subareasCn=runoff coefficient for nth subareaAn=nth subarea size (ha)

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 4: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

4of 39

d Under the assumptions of the Rational Method the longer travel time is taken asthe time of concentration Therefore for existing conditions the time ofconcentration Te is 262 minutes For future conditions the time of concentrationTf is 247 minutes

Step 3

Ensure limitations of the Rational Method have not been exceeded

Because the total drainage area is less than 80 ha no appreciable storage is indicated andthe watershed shape is not unusual the Rational Method may be used

Step 4

Select coefficients for the 10-year and 100-year flood frequencies for Hays County

Use Hydrology documentbull e10 = 0776 b10 = 1981 d10 = 86bull e100 = 0755 b100 = 2642 d100 = 82

Step 5

Calculate the rainfall intensity using Equation 5-5a For existing conditions

( ) ( )I b

t d1981

26 8612610

ce 0776=

+=

+=

2mmhr

( ) ( )I b

t d2642

26 82100

ce 0755=

+=

+=

2183mmhr

b For future conditions

( ) ( )I b

t d1981

247 8613110

ce 0776=

+=

+= mmhr

( ) ( )I b

t d2642

82100

ce 0755=

+=

+=

24 7189

mmhr

Step 6

Calculate composite runoff coefficienta For existing conditions the area is homogeneous with C = 025b For future conditions

5of 39

CC A C A

A A025(14) 06(5)

14 501 1 2 2

1 2

=++

= ++

= 34

Step 7

Calculate peak discharges using Equation 5-5 and the Runoff Curve Numbers for UrbanAreas

a For 10 year Cf = 10 For 100 year Cf = 125b For existing conditions

Q CIA360

(025)(126)(19) 360 166 m s103= = =

Q CC IA

360 (025)(125)(183)(19) 360 302 m s100

f 3= = =

c For future conditions

Q CIA360

(034)(131)(19) 360 235 m s103= = =

Q CC IA

360 (034)(125)(189)(19) 360 424 m s100

f 3= = =

Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions

The following is an example of a rainfall hyetograph for a 25-year 24-hour storm in HarrisCounty For demonstration only a one-hour time increment is used

Total precipitation (from Hydrology ) = 244 mm

Distribution type (from Figure 5-8) = III

The Rainfall Groups for Antecedent Soil Moisture Conditions During Growing andDormant Seasons presents the calculations Figure 5-11 shows the resulting hyetograph

For time = 1 hour

1 The cumulative fraction is determined by interpolation of the Runoff Curve Numbersfor Arid and Semi Arid Rangelands P1P24 = 0 +(002ndash0) times (1ndash0)(2-0) = 001

2 The cumulative rainfall is the product of the cumulative fraction and the total 24-hourrainfall P1 = 001 times 244 = 244 mm

3 The incremental rainfall is the difference between the current and preceding cumulativerainfall values 244ndash0 = 244 mm

Repeating the procedure for each time period yields the complete hyetograph ordinates

6of 39

Hyetograph Example Using the Balanced Storm Method

The following represents the development of a five-year three-hour duration rainfallhyetograph for Travis County The rainfall intensity coefficients are e = 078 b = 1753 d =86 (Appendix B) The duration is 3 hours = 180 minutes Using 15 minute intervals thetotal number of intervals is 18015 = 12 For a duration of 15 minutes

diams the intensity is 1753(15 + 86)078 = 14891 mmhour (using Equation 5-5 where theduration replaces time of concentration)

diams the cumulative depth is 14891 times 15 (min) 60 (min per hour) = 3723 mm

diams the incremental depth is 3723ndash0 = 3723 mm

Calculation of the values for each duration up to 180 minutes is similar The Example ofBalanced Storm table tabulates the calculations The highest incremental rainfall (always atthe shortest duration) is 3723 mm This is assigned the central time block of 75ndash90 minutesThe next highest 1350 is assigned to the 90ndash105 minute time block which is after thecentral block The next highest increment is 817 and is assigned to the 60ndash75 minute timeblock which immediately precedes the central time block This distribution continuesalternating between next available time blocks from the central block Figure F-2 shows theresulting hyetograph

7of 39

Example of Balanced Storm TabulationDuration

(min)Intensity(mmhr)

Cum Depth(mm)

Incr Depth(mm)

Time Block(mm)

Rainfall(mm)

15 14891 3723 3723 0-- 15 21230 10145 5072 1350 15-30 25645 7853 5890 817 30-45 32760 6478 6478 588 45-60 46275 5552 6940 462 60-75 81790 4882 7322 382 75-90 3723105 4371 7649 327 90-105 1350120 3968 7936 287 105-120 588135 3641 8192 256 120-135 382150 3369 8423 231 135-150 287165 3140 8635 212 150-165 231180 2943 8830 195 165-180 195

Figure F-2 Example of Hyetograph Using Balanced Storm Method

8of 39

Muskingum Method

The example shown in the Channel Routing Using the Muskingum Method table shows atriangular hydrograph routed through three 1000 meter reaches of channel The outflowhydrograph for each reach is used as the inflow for the next The channel has a lsquoKrsquo of 0278hours (1000 seconds) and an times of 02

Using Equations 5-30 5-31 and 5-32 with a time increment of 1000 sec

C11000 2 1000 0 2

2 1000 1 0 2 10000 23077= minus

minus +=( )( )

( )( )

C21000 2 1000 0 2

2 1000 1 0 2 1000053846= +

minus +=( )( )

( )( )

C32 1000 1 0 2 10002 1000 1 0 2 1000

0 23077= minus minusminus +

=( )( )( )( )

Check C1 + C2 + C3 = 023077 + 023077 + 053846 = 1

For time step two (t = 2) first reach

O2 = (023077)(200) + (053846)(0) + (023077)(0) = 4615 m3s

For time step 3 (t = 3)

O3 = (023077)(400) + (053846)(200) + (023077)(4615) = 21065 m3s

Repeating the process until the outflow hydrograph is complete The outflow hydrographfrom reach one becomes the inflow hydrograph for reach 2 and the process is repeated forreaches 2 and 3 Figure F-3 shows a plot of the hydrographs Since the outflow hydrographrepresents a displacement in distance as well as time the peak outflow does not coincidewith the receding limb of the inflow hydrograph

9of 39

Channel Routing Using the Muskingum MethodOutflow (m8s)Time

stepTime

(s)Inflow(m8s) Reach 1 Reach 2 Reach 3

1 0 0 0 0 02 1000 200 4615 1065 2463 2000 400 21065 7592 23824 3000 300 33323 20785 94345 4000 200 28459 29307 201326 5000 100 19644 26621 265707 6000 9918 19010 248528 7000 2289 10255 183389 8000 528 3721 1061310 9000 122 1171 472311 10000 028 3472 180012 11000 006 096 62213 12000 001 026 20114 13000 000 007 06215 14000 000 002 01816 15000 000 000 00517 16000 000 000 00218 17000 000 000 000

10of 39

Figure F-3 Plot of a Triangular Hydrograph Routed Through Three Segments of Channel

Standard Step Method

Four cross sections along a reach are shown in Figures 7-17 7-18 7-19 7-20 Each crosssection is separated by 1524 m and is subdivided according to geometry and roughnessThe calculations shown in WS Elevation of 235 m represent one set of water-surfacecalculations An explanation of WS Elevation of 235 m follows the calculations Thecalculations represent the results of iterations at each section

Column 1 This column contains the cross section identification name

Column 2 This column contains the stream cross section station number

Column 3 The assumed water surface elevation must agree with the resulting computedwater surface elevation within plusmn 005 meters (or some other allowable tolerance) fortrial calculations to be successful

Column 4 This is the stage-discharge (rating) curve value for the first section thereafter itis the value calculated by adding ∆WS (Column 21) to the computed water surfaceelevation for the previous cross section

11of 39

Column 5 A is the cross-sectional area If the section is complex and has been subdividedinto several parts (eg left overbank channel and right overbank) then use one line ofthe form for each subsection and add to get the total area of cross section (At)

Column 6 This column contains the wetted perimeter If the section is subdivided thenuse one line for each subsection wetted perimeter

Column 7 R is the hydraulic radius Use the same procedure as for Column 5 if the sectionis complex but do not add subsection values

Column 8 n is Manningrsquos coefficient of channel roughness

Column 9 K is the conveyance and is determined with Equation 6-4 This column containsthe total conveyance for the cross section If the cross section is complex addsubsection K values to get the total conveyance (Kt)

Column 10 Kave the average conveyance for the reach is computed with Equation F-1

( )K = 12

K + Kave ds us

Equation F-1

Column 11 This column contains the friction slope at the current section and is computedusing Equation 67ndash8

S QKf =

2

Equation F-2

Column 12 The average friction slope is determined using Equation F-3

S QKf ave =

ave

2

Equation F-3

Column 13 L is the distance between cross-sections

Column 14 The energy loss due to friction (hf) through the reach is calculated usingEquation F-4

h = S Lf aveEquation F-4

Column 15 This column contains part of the expression relating distributed flow velocitiesto an average value (see Column 16) If the section is complex calculate one of thesevalues for each subsection and add all subsection values to get a total If one

12of 39

subsection is used you do not need Column 15 and the kinetic energy coefficient(Column 16) equals 10

Column 16 The kinetic energy coefficient (α) is calculated with Equation 6-10

Column 17 The average velocity (V) for the cross section is calculated with the continuityequation (Equation 6-1)

Column 18 This column contains the average velocity head corrected for flowdistribution

Column 19 This column contains the difference between the downstream and upstreamvelocity heads A positive value indicates velocity is increasing therefore use acontraction coefficient to account for ldquoother lossesrdquo A negative value indicates theexpansion coefficient should be used in calculating ldquoother lossesrdquo

Column 20 Calculate the ldquoother lossesrdquo by multiplying either the expansion coefficient(Ke) or contraction coefficient (Kc) by the absolute value of Column 18 That is forexpansion the change in velocity head will be negative but the head loss must bepositive ∆WS is the change in water surface elevation from the previous cross sectionIt is the algebraic sum of Columns 14 19 and 20

Storm Drain Design

Problem Statement

Given The working schematic Figure F-4 shows the layout of the roadway and crossstreets to be drained At the node indicated as A8 on the schematic an outflow from asmall storm drain system within the indicated shopping mall is accepted into thedepartmentrsquos system The storm drain system will outfall into a channel which isdirectly downstream of a culvert as indicated The culvert accommodates flow from a9065 hectare watershed

13of 39

Figure F-4 Layout of Drainage Areas and Inlets

14of 39

The hydrology and inlet data for this example are given in Hydrology and Inlet Informationtable This table includes the following for each drainage area

diams area

diams time of concentration

diams gutter slope

diams reciprocal of the cross slope

Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

A1 Curb 069010

055085 75 24 00050

A2 SGrate 006 070 20 32B1 Slot 011 085 32 24

00050C1 Curb 078

014050085 145 32 00060

A3 SGrate 010 070 20 32D1 Slot 014 085 41 32 00060E1 Slot 022 050 50 48 00065E2 Curb 042

011055085 135 48 00060

A4 JuncG1 Curb 041

011050085 90 32 00060

A5 SGrate 005 070 20 32F1 Slot 009 085 36 32 00060H1 Curb 008

006055085 60 48 00030

H2 Curb 012022

055085 65 48 00050

15of 39

(continued) Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

I1 Slot 032007

055085 80 48 00030

K1 Grate 066013

040085 150 48 00040

J1 Scurb 043021

060085 88 32

L1 Grate 030007

055085 177 48 00040

L2 Grate 024 085 36 48 00040L3 Grate 017 085 30 48 00040A6 JuncM1 SCurb 033 085 42 32A7 SGrate 004 070 20 32N1 SCurb 041 085 70 32Offsite 018

149070085 116

A8 JuncA9 Sgrate 012 070 34 32A10 Outfall

The Conduit Information table presents conduit design information such as soffitelevations and pipe lengths The General Given Information table contains generalinformation including

diams rainfall intensity factors

diams allowable ponded widths and

diams inlet requirements

16of 39

Conduit InformationIdentificationsUS DS

Length (m) US Soffit Elev (m)

A1 A2 20 256760B1 A2 20 256730A2 A3 100 256670C1 A3 20 256260D1 A3 20 256270A3 A4 20 256200E1 E2 90 256600E2 A4 20 256150A4 A5 75 256090G1 A5 20 255810F1 A5 25 255830A5 A6 75 255730J1 G1 25 255940H1 H2 125 255880I1 H2 60 255810H2 A6 57 255560L1 L2 95 256320K1 L2 55 256070L2 L3 86 255850L3 A6 20 255570A6 A7 56 255490M1 A7 20 255300N1 A7 18 255240A7 A8 60 255220A8 A9 104 254880A9 A10 40 254270

17of 39

General Given InformationDesign Frequency 5 years (20 chance of exceedance)Rainfall intensity factors e = 078 b = 1422 mm d = 82Curb height 015 mMinimum time of concentration 10 minutesMinimum curb inlet length 15 mMinimum slotted drain inlet length 6 mStandard grate inlets Parallel bars wtransverse rods

W = 05 m and L = 1 mGrate inlets on sag in median 05 m x 05 m square inlets bar area =

25 of grate area allowable pondeddepth = 06 m

Gutter depression for curb inlets 75 mmAllowable ponded width 36 m on Lone Star Blvd and 45 m on

Texas AveCurb inlets on sag slope = 00050 mm and 50 of

discharge on each side of inletOutfall tailwater elevation (2 yr) 254360 m

Required Design a storm drain system to accommodate the design discharge

Discussion The following example represents a single iteration of the design process It isone of a series of iterations that would require revision re-analysis and optimizationuntil a technically acceptable and economical design is accomplished

In a production design all design parameters and criteria must be met The illustration ofthe hydraulic grade line is for demonstration only Typically the hydraulic grade line isdeveloped as a last design step after the system has been optimized The next subsectionsoffer initial design process components and a design iteration procedure

Initial Design Process Components

The initial design process consists basically of the following three components

diams hydrology

diams inlet design and

diams conduit design

These components will be addressed individually However it is important to understandthat all three components must function together simultaneously You must evaluate thehydrology aspects with respect to both inlet design and conduit design

18of 39

Design Iteration Procedure

The following steps illustrate the activities in a single design iteration

Design Iteration ProcedureStep Action

Step 1 Prepare a system planStep 2 Base initial runoff computations on Rational Method and tabulate them in

Conduit Information tableStep 3 Locate inlets based on logic and hydraulic demand and configure the conduit

system

Step 1

Prepare a system plan

Prepare a system plan as discussed in Section 2 System Planning Effectively the exampleproblem is identified as delineated in the problem statement Ensure there are no ldquodeadrdquospots where the runoff has no outlet Establish the general location of inlets the laterals andthe trunk lines You must coordinate the logical location of the various system componentswith the component locations necessary to satisfy hydraulic demand In subsequent designiterations you may change any or all parts of the system configuration as necessary

a Establish the design parameters and criteriab Select materials and shapes to be usedc Assign the design frequencyd Identify utility intersections with respect to

bull locationbull typebull owner and probable disposition

e Identify detention facilities

19of 39

Step 2

Base initial runoff computations on the Rational Method and tabulate them in ConduitInformation table The first four columns of this tabulation are self-explanatory The totalCA as shown in the fifth column is computed by multiplying each incremental area by itscorresponding coefficient of runoff and summing these incremental products As anexample the total CA for drainage area A1 is computed as follows

Type Hectares C CAPaved 010 x 085 = 0085Residential 069 x 055 = 0380TOTALS 079 0465

20of 39

Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

A1 Curb 069010

055085

0465 75 100 14793 0191

A2 SGrate 006 070 0042 20 100 14793 0017B1 Slot 011 085 0094 32 100 14793 0038C1 Curb 078

014050085 0509 145 145 12451 0176

A3 SGrate 010 070 0070 20 100 14793 0029D1 Slot 014 085 0119 41 100 14793 0049E1 Slot 022 050 0110 50 100 14793 0045E2 Curb 042

011055085 0325 135 135 12896 0116

A4 Junc 000 000G1 Curb 041

011050085 0299 90 100 14793 0123

A5 SGrate 005 070 0035 20 100 14793 0014F1 Slot 009 085 0077 36 100 14793 0031H1 Curb 008

006055085 0095 60 100 14793 0039

H2 Curb 012022

055085 0253 65 100 14793 0104

I1 Slot 032007

055085 0236 80 100 14793 0097

21of 39

(continued) Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

K1 Grate 066013

040085 0375 150 150 12241 0127

J1 SCurb 043021

060085 0437 88 100 14793 0180

L1 Grate 030007

055085 0225 177 177 11234 0070

L2 Grate 024 085 0204 36 100 14793 0084L3 Grate 017 085 0145 30 100 14793 0059A6 Junc 000 000M1 SCurb 033 085 0281 42 100 14793 0115A7 SGrate 004 070 0028 20 100 14793 0012N1 SCurb 041 085 0349 70 100 14793 0143Offsite 018

149070085 1393 116 116 13852 0536

A8 Junc 000 000A9 SGrate 012 070 0084 34 100 14793 0035A10 Outfall 000 000

a In the Summary of Hydrologic Computations table note that the operating timeof concentration has a minimum value of 10 minutes (according to departmentpractice) However it is necessary to account for the smaller time of concentrationtherefore the actual time of concentration (minimum notwithstanding) is alsotabulated

b The rainfall intensity (I) is based on Equation F-5 where e = 078 b = 1422 and d= 82 For drainage area A1 the time of concentration is only 75 minutesTherefore using 10 minutes as a basis the rainfall intensity is calculated as 1479mmhr

If =b

tc + d( )e

Equation F-5where

If=rainfall intensity for frequency (mmhr)tc=time of concentration (min)e b d= empirical factors which are tabulated for each county in Texas

for frequencies of 2 5 10 25 50 and 100 years in Appendix Bc The peak discharge (Q) is determined by multiplying CA by I and 000278

(Equation F-6)

Q = C I A360

22of 39

Equation F-6whereQ =peak discharge (m3s)C =runoff coefficientI =rainfall intensity associated with a specific frequency (mmhr)A =area of the watershed (ha)

d For watershed A1 Q is 0191 m3sStep 3

Locate the inlets based on logic and hydraulic demand and configure the conduit systema Locate the inlets based on logic and hydraulic demand as outlined in Section 5

Storm Drain Inletsb Finally after locating the inlets (establishing the nodes for the storm drain system)

you can configure the conduit system

Tables F-7 to F-13 show the suggested tabular format for calculations in the design of theinlet system in this example Since the design process is iterative requiring adjustments andre-analysis until the design is optimized the examples shown are only a ldquosnapshotrdquo (or oneiteration) during the design process

Inlets On-Grade Explanation

C = =

=

C A

A

n nn

m

nn

m1

1

Equation F-7where

C=weighted runoff coefficientn=nth subaream=number of subareasCn=runoff coefficient for nth subareaAn=nth subarea size (ha)

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 5: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

5of 39

CC A C A

A A025(14) 06(5)

14 501 1 2 2

1 2

=++

= ++

= 34

Step 7

Calculate peak discharges using Equation 5-5 and the Runoff Curve Numbers for UrbanAreas

a For 10 year Cf = 10 For 100 year Cf = 125b For existing conditions

Q CIA360

(025)(126)(19) 360 166 m s103= = =

Q CC IA

360 (025)(125)(183)(19) 360 302 m s100

f 3= = =

c For future conditions

Q CIA360

(034)(131)(19) 360 235 m s103= = =

Q CC IA

360 (034)(125)(189)(19) 360 424 m s100

f 3= = =

Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions

The following is an example of a rainfall hyetograph for a 25-year 24-hour storm in HarrisCounty For demonstration only a one-hour time increment is used

Total precipitation (from Hydrology ) = 244 mm

Distribution type (from Figure 5-8) = III

The Rainfall Groups for Antecedent Soil Moisture Conditions During Growing andDormant Seasons presents the calculations Figure 5-11 shows the resulting hyetograph

For time = 1 hour

1 The cumulative fraction is determined by interpolation of the Runoff Curve Numbersfor Arid and Semi Arid Rangelands P1P24 = 0 +(002ndash0) times (1ndash0)(2-0) = 001

2 The cumulative rainfall is the product of the cumulative fraction and the total 24-hourrainfall P1 = 001 times 244 = 244 mm

3 The incremental rainfall is the difference between the current and preceding cumulativerainfall values 244ndash0 = 244 mm

Repeating the procedure for each time period yields the complete hyetograph ordinates

6of 39

Hyetograph Example Using the Balanced Storm Method

The following represents the development of a five-year three-hour duration rainfallhyetograph for Travis County The rainfall intensity coefficients are e = 078 b = 1753 d =86 (Appendix B) The duration is 3 hours = 180 minutes Using 15 minute intervals thetotal number of intervals is 18015 = 12 For a duration of 15 minutes

diams the intensity is 1753(15 + 86)078 = 14891 mmhour (using Equation 5-5 where theduration replaces time of concentration)

diams the cumulative depth is 14891 times 15 (min) 60 (min per hour) = 3723 mm

diams the incremental depth is 3723ndash0 = 3723 mm

Calculation of the values for each duration up to 180 minutes is similar The Example ofBalanced Storm table tabulates the calculations The highest incremental rainfall (always atthe shortest duration) is 3723 mm This is assigned the central time block of 75ndash90 minutesThe next highest 1350 is assigned to the 90ndash105 minute time block which is after thecentral block The next highest increment is 817 and is assigned to the 60ndash75 minute timeblock which immediately precedes the central time block This distribution continuesalternating between next available time blocks from the central block Figure F-2 shows theresulting hyetograph

7of 39

Example of Balanced Storm TabulationDuration

(min)Intensity(mmhr)

Cum Depth(mm)

Incr Depth(mm)

Time Block(mm)

Rainfall(mm)

15 14891 3723 3723 0-- 15 21230 10145 5072 1350 15-30 25645 7853 5890 817 30-45 32760 6478 6478 588 45-60 46275 5552 6940 462 60-75 81790 4882 7322 382 75-90 3723105 4371 7649 327 90-105 1350120 3968 7936 287 105-120 588135 3641 8192 256 120-135 382150 3369 8423 231 135-150 287165 3140 8635 212 150-165 231180 2943 8830 195 165-180 195

Figure F-2 Example of Hyetograph Using Balanced Storm Method

8of 39

Muskingum Method

The example shown in the Channel Routing Using the Muskingum Method table shows atriangular hydrograph routed through three 1000 meter reaches of channel The outflowhydrograph for each reach is used as the inflow for the next The channel has a lsquoKrsquo of 0278hours (1000 seconds) and an times of 02

Using Equations 5-30 5-31 and 5-32 with a time increment of 1000 sec

C11000 2 1000 0 2

2 1000 1 0 2 10000 23077= minus

minus +=( )( )

( )( )

C21000 2 1000 0 2

2 1000 1 0 2 1000053846= +

minus +=( )( )

( )( )

C32 1000 1 0 2 10002 1000 1 0 2 1000

0 23077= minus minusminus +

=( )( )( )( )

Check C1 + C2 + C3 = 023077 + 023077 + 053846 = 1

For time step two (t = 2) first reach

O2 = (023077)(200) + (053846)(0) + (023077)(0) = 4615 m3s

For time step 3 (t = 3)

O3 = (023077)(400) + (053846)(200) + (023077)(4615) = 21065 m3s

Repeating the process until the outflow hydrograph is complete The outflow hydrographfrom reach one becomes the inflow hydrograph for reach 2 and the process is repeated forreaches 2 and 3 Figure F-3 shows a plot of the hydrographs Since the outflow hydrographrepresents a displacement in distance as well as time the peak outflow does not coincidewith the receding limb of the inflow hydrograph

9of 39

Channel Routing Using the Muskingum MethodOutflow (m8s)Time

stepTime

(s)Inflow(m8s) Reach 1 Reach 2 Reach 3

1 0 0 0 0 02 1000 200 4615 1065 2463 2000 400 21065 7592 23824 3000 300 33323 20785 94345 4000 200 28459 29307 201326 5000 100 19644 26621 265707 6000 9918 19010 248528 7000 2289 10255 183389 8000 528 3721 1061310 9000 122 1171 472311 10000 028 3472 180012 11000 006 096 62213 12000 001 026 20114 13000 000 007 06215 14000 000 002 01816 15000 000 000 00517 16000 000 000 00218 17000 000 000 000

10of 39

Figure F-3 Plot of a Triangular Hydrograph Routed Through Three Segments of Channel

Standard Step Method

Four cross sections along a reach are shown in Figures 7-17 7-18 7-19 7-20 Each crosssection is separated by 1524 m and is subdivided according to geometry and roughnessThe calculations shown in WS Elevation of 235 m represent one set of water-surfacecalculations An explanation of WS Elevation of 235 m follows the calculations Thecalculations represent the results of iterations at each section

Column 1 This column contains the cross section identification name

Column 2 This column contains the stream cross section station number

Column 3 The assumed water surface elevation must agree with the resulting computedwater surface elevation within plusmn 005 meters (or some other allowable tolerance) fortrial calculations to be successful

Column 4 This is the stage-discharge (rating) curve value for the first section thereafter itis the value calculated by adding ∆WS (Column 21) to the computed water surfaceelevation for the previous cross section

11of 39

Column 5 A is the cross-sectional area If the section is complex and has been subdividedinto several parts (eg left overbank channel and right overbank) then use one line ofthe form for each subsection and add to get the total area of cross section (At)

Column 6 This column contains the wetted perimeter If the section is subdivided thenuse one line for each subsection wetted perimeter

Column 7 R is the hydraulic radius Use the same procedure as for Column 5 if the sectionis complex but do not add subsection values

Column 8 n is Manningrsquos coefficient of channel roughness

Column 9 K is the conveyance and is determined with Equation 6-4 This column containsthe total conveyance for the cross section If the cross section is complex addsubsection K values to get the total conveyance (Kt)

Column 10 Kave the average conveyance for the reach is computed with Equation F-1

( )K = 12

K + Kave ds us

Equation F-1

Column 11 This column contains the friction slope at the current section and is computedusing Equation 67ndash8

S QKf =

2

Equation F-2

Column 12 The average friction slope is determined using Equation F-3

S QKf ave =

ave

2

Equation F-3

Column 13 L is the distance between cross-sections

Column 14 The energy loss due to friction (hf) through the reach is calculated usingEquation F-4

h = S Lf aveEquation F-4

Column 15 This column contains part of the expression relating distributed flow velocitiesto an average value (see Column 16) If the section is complex calculate one of thesevalues for each subsection and add all subsection values to get a total If one

12of 39

subsection is used you do not need Column 15 and the kinetic energy coefficient(Column 16) equals 10

Column 16 The kinetic energy coefficient (α) is calculated with Equation 6-10

Column 17 The average velocity (V) for the cross section is calculated with the continuityequation (Equation 6-1)

Column 18 This column contains the average velocity head corrected for flowdistribution

Column 19 This column contains the difference between the downstream and upstreamvelocity heads A positive value indicates velocity is increasing therefore use acontraction coefficient to account for ldquoother lossesrdquo A negative value indicates theexpansion coefficient should be used in calculating ldquoother lossesrdquo

Column 20 Calculate the ldquoother lossesrdquo by multiplying either the expansion coefficient(Ke) or contraction coefficient (Kc) by the absolute value of Column 18 That is forexpansion the change in velocity head will be negative but the head loss must bepositive ∆WS is the change in water surface elevation from the previous cross sectionIt is the algebraic sum of Columns 14 19 and 20

Storm Drain Design

Problem Statement

Given The working schematic Figure F-4 shows the layout of the roadway and crossstreets to be drained At the node indicated as A8 on the schematic an outflow from asmall storm drain system within the indicated shopping mall is accepted into thedepartmentrsquos system The storm drain system will outfall into a channel which isdirectly downstream of a culvert as indicated The culvert accommodates flow from a9065 hectare watershed

13of 39

Figure F-4 Layout of Drainage Areas and Inlets

14of 39

The hydrology and inlet data for this example are given in Hydrology and Inlet Informationtable This table includes the following for each drainage area

diams area

diams time of concentration

diams gutter slope

diams reciprocal of the cross slope

Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

A1 Curb 069010

055085 75 24 00050

A2 SGrate 006 070 20 32B1 Slot 011 085 32 24

00050C1 Curb 078

014050085 145 32 00060

A3 SGrate 010 070 20 32D1 Slot 014 085 41 32 00060E1 Slot 022 050 50 48 00065E2 Curb 042

011055085 135 48 00060

A4 JuncG1 Curb 041

011050085 90 32 00060

A5 SGrate 005 070 20 32F1 Slot 009 085 36 32 00060H1 Curb 008

006055085 60 48 00030

H2 Curb 012022

055085 65 48 00050

15of 39

(continued) Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

I1 Slot 032007

055085 80 48 00030

K1 Grate 066013

040085 150 48 00040

J1 Scurb 043021

060085 88 32

L1 Grate 030007

055085 177 48 00040

L2 Grate 024 085 36 48 00040L3 Grate 017 085 30 48 00040A6 JuncM1 SCurb 033 085 42 32A7 SGrate 004 070 20 32N1 SCurb 041 085 70 32Offsite 018

149070085 116

A8 JuncA9 Sgrate 012 070 34 32A10 Outfall

The Conduit Information table presents conduit design information such as soffitelevations and pipe lengths The General Given Information table contains generalinformation including

diams rainfall intensity factors

diams allowable ponded widths and

diams inlet requirements

16of 39

Conduit InformationIdentificationsUS DS

Length (m) US Soffit Elev (m)

A1 A2 20 256760B1 A2 20 256730A2 A3 100 256670C1 A3 20 256260D1 A3 20 256270A3 A4 20 256200E1 E2 90 256600E2 A4 20 256150A4 A5 75 256090G1 A5 20 255810F1 A5 25 255830A5 A6 75 255730J1 G1 25 255940H1 H2 125 255880I1 H2 60 255810H2 A6 57 255560L1 L2 95 256320K1 L2 55 256070L2 L3 86 255850L3 A6 20 255570A6 A7 56 255490M1 A7 20 255300N1 A7 18 255240A7 A8 60 255220A8 A9 104 254880A9 A10 40 254270

17of 39

General Given InformationDesign Frequency 5 years (20 chance of exceedance)Rainfall intensity factors e = 078 b = 1422 mm d = 82Curb height 015 mMinimum time of concentration 10 minutesMinimum curb inlet length 15 mMinimum slotted drain inlet length 6 mStandard grate inlets Parallel bars wtransverse rods

W = 05 m and L = 1 mGrate inlets on sag in median 05 m x 05 m square inlets bar area =

25 of grate area allowable pondeddepth = 06 m

Gutter depression for curb inlets 75 mmAllowable ponded width 36 m on Lone Star Blvd and 45 m on

Texas AveCurb inlets on sag slope = 00050 mm and 50 of

discharge on each side of inletOutfall tailwater elevation (2 yr) 254360 m

Required Design a storm drain system to accommodate the design discharge

Discussion The following example represents a single iteration of the design process It isone of a series of iterations that would require revision re-analysis and optimizationuntil a technically acceptable and economical design is accomplished

In a production design all design parameters and criteria must be met The illustration ofthe hydraulic grade line is for demonstration only Typically the hydraulic grade line isdeveloped as a last design step after the system has been optimized The next subsectionsoffer initial design process components and a design iteration procedure

Initial Design Process Components

The initial design process consists basically of the following three components

diams hydrology

diams inlet design and

diams conduit design

These components will be addressed individually However it is important to understandthat all three components must function together simultaneously You must evaluate thehydrology aspects with respect to both inlet design and conduit design

18of 39

Design Iteration Procedure

The following steps illustrate the activities in a single design iteration

Design Iteration ProcedureStep Action

Step 1 Prepare a system planStep 2 Base initial runoff computations on Rational Method and tabulate them in

Conduit Information tableStep 3 Locate inlets based on logic and hydraulic demand and configure the conduit

system

Step 1

Prepare a system plan

Prepare a system plan as discussed in Section 2 System Planning Effectively the exampleproblem is identified as delineated in the problem statement Ensure there are no ldquodeadrdquospots where the runoff has no outlet Establish the general location of inlets the laterals andthe trunk lines You must coordinate the logical location of the various system componentswith the component locations necessary to satisfy hydraulic demand In subsequent designiterations you may change any or all parts of the system configuration as necessary

a Establish the design parameters and criteriab Select materials and shapes to be usedc Assign the design frequencyd Identify utility intersections with respect to

bull locationbull typebull owner and probable disposition

e Identify detention facilities

19of 39

Step 2

Base initial runoff computations on the Rational Method and tabulate them in ConduitInformation table The first four columns of this tabulation are self-explanatory The totalCA as shown in the fifth column is computed by multiplying each incremental area by itscorresponding coefficient of runoff and summing these incremental products As anexample the total CA for drainage area A1 is computed as follows

Type Hectares C CAPaved 010 x 085 = 0085Residential 069 x 055 = 0380TOTALS 079 0465

20of 39

Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

A1 Curb 069010

055085

0465 75 100 14793 0191

A2 SGrate 006 070 0042 20 100 14793 0017B1 Slot 011 085 0094 32 100 14793 0038C1 Curb 078

014050085 0509 145 145 12451 0176

A3 SGrate 010 070 0070 20 100 14793 0029D1 Slot 014 085 0119 41 100 14793 0049E1 Slot 022 050 0110 50 100 14793 0045E2 Curb 042

011055085 0325 135 135 12896 0116

A4 Junc 000 000G1 Curb 041

011050085 0299 90 100 14793 0123

A5 SGrate 005 070 0035 20 100 14793 0014F1 Slot 009 085 0077 36 100 14793 0031H1 Curb 008

006055085 0095 60 100 14793 0039

H2 Curb 012022

055085 0253 65 100 14793 0104

I1 Slot 032007

055085 0236 80 100 14793 0097

21of 39

(continued) Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

K1 Grate 066013

040085 0375 150 150 12241 0127

J1 SCurb 043021

060085 0437 88 100 14793 0180

L1 Grate 030007

055085 0225 177 177 11234 0070

L2 Grate 024 085 0204 36 100 14793 0084L3 Grate 017 085 0145 30 100 14793 0059A6 Junc 000 000M1 SCurb 033 085 0281 42 100 14793 0115A7 SGrate 004 070 0028 20 100 14793 0012N1 SCurb 041 085 0349 70 100 14793 0143Offsite 018

149070085 1393 116 116 13852 0536

A8 Junc 000 000A9 SGrate 012 070 0084 34 100 14793 0035A10 Outfall 000 000

a In the Summary of Hydrologic Computations table note that the operating timeof concentration has a minimum value of 10 minutes (according to departmentpractice) However it is necessary to account for the smaller time of concentrationtherefore the actual time of concentration (minimum notwithstanding) is alsotabulated

b The rainfall intensity (I) is based on Equation F-5 where e = 078 b = 1422 and d= 82 For drainage area A1 the time of concentration is only 75 minutesTherefore using 10 minutes as a basis the rainfall intensity is calculated as 1479mmhr

If =b

tc + d( )e

Equation F-5where

If=rainfall intensity for frequency (mmhr)tc=time of concentration (min)e b d= empirical factors which are tabulated for each county in Texas

for frequencies of 2 5 10 25 50 and 100 years in Appendix Bc The peak discharge (Q) is determined by multiplying CA by I and 000278

(Equation F-6)

Q = C I A360

22of 39

Equation F-6whereQ =peak discharge (m3s)C =runoff coefficientI =rainfall intensity associated with a specific frequency (mmhr)A =area of the watershed (ha)

d For watershed A1 Q is 0191 m3sStep 3

Locate the inlets based on logic and hydraulic demand and configure the conduit systema Locate the inlets based on logic and hydraulic demand as outlined in Section 5

Storm Drain Inletsb Finally after locating the inlets (establishing the nodes for the storm drain system)

you can configure the conduit system

Tables F-7 to F-13 show the suggested tabular format for calculations in the design of theinlet system in this example Since the design process is iterative requiring adjustments andre-analysis until the design is optimized the examples shown are only a ldquosnapshotrdquo (or oneiteration) during the design process

Inlets On-Grade Explanation

C = =

=

C A

A

n nn

m

nn

m1

1

Equation F-7where

C=weighted runoff coefficientn=nth subaream=number of subareasCn=runoff coefficient for nth subareaAn=nth subarea size (ha)

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 6: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

6of 39

Hyetograph Example Using the Balanced Storm Method

The following represents the development of a five-year three-hour duration rainfallhyetograph for Travis County The rainfall intensity coefficients are e = 078 b = 1753 d =86 (Appendix B) The duration is 3 hours = 180 minutes Using 15 minute intervals thetotal number of intervals is 18015 = 12 For a duration of 15 minutes

diams the intensity is 1753(15 + 86)078 = 14891 mmhour (using Equation 5-5 where theduration replaces time of concentration)

diams the cumulative depth is 14891 times 15 (min) 60 (min per hour) = 3723 mm

diams the incremental depth is 3723ndash0 = 3723 mm

Calculation of the values for each duration up to 180 minutes is similar The Example ofBalanced Storm table tabulates the calculations The highest incremental rainfall (always atthe shortest duration) is 3723 mm This is assigned the central time block of 75ndash90 minutesThe next highest 1350 is assigned to the 90ndash105 minute time block which is after thecentral block The next highest increment is 817 and is assigned to the 60ndash75 minute timeblock which immediately precedes the central time block This distribution continuesalternating between next available time blocks from the central block Figure F-2 shows theresulting hyetograph

7of 39

Example of Balanced Storm TabulationDuration

(min)Intensity(mmhr)

Cum Depth(mm)

Incr Depth(mm)

Time Block(mm)

Rainfall(mm)

15 14891 3723 3723 0-- 15 21230 10145 5072 1350 15-30 25645 7853 5890 817 30-45 32760 6478 6478 588 45-60 46275 5552 6940 462 60-75 81790 4882 7322 382 75-90 3723105 4371 7649 327 90-105 1350120 3968 7936 287 105-120 588135 3641 8192 256 120-135 382150 3369 8423 231 135-150 287165 3140 8635 212 150-165 231180 2943 8830 195 165-180 195

Figure F-2 Example of Hyetograph Using Balanced Storm Method

8of 39

Muskingum Method

The example shown in the Channel Routing Using the Muskingum Method table shows atriangular hydrograph routed through three 1000 meter reaches of channel The outflowhydrograph for each reach is used as the inflow for the next The channel has a lsquoKrsquo of 0278hours (1000 seconds) and an times of 02

Using Equations 5-30 5-31 and 5-32 with a time increment of 1000 sec

C11000 2 1000 0 2

2 1000 1 0 2 10000 23077= minus

minus +=( )( )

( )( )

C21000 2 1000 0 2

2 1000 1 0 2 1000053846= +

minus +=( )( )

( )( )

C32 1000 1 0 2 10002 1000 1 0 2 1000

0 23077= minus minusminus +

=( )( )( )( )

Check C1 + C2 + C3 = 023077 + 023077 + 053846 = 1

For time step two (t = 2) first reach

O2 = (023077)(200) + (053846)(0) + (023077)(0) = 4615 m3s

For time step 3 (t = 3)

O3 = (023077)(400) + (053846)(200) + (023077)(4615) = 21065 m3s

Repeating the process until the outflow hydrograph is complete The outflow hydrographfrom reach one becomes the inflow hydrograph for reach 2 and the process is repeated forreaches 2 and 3 Figure F-3 shows a plot of the hydrographs Since the outflow hydrographrepresents a displacement in distance as well as time the peak outflow does not coincidewith the receding limb of the inflow hydrograph

9of 39

Channel Routing Using the Muskingum MethodOutflow (m8s)Time

stepTime

(s)Inflow(m8s) Reach 1 Reach 2 Reach 3

1 0 0 0 0 02 1000 200 4615 1065 2463 2000 400 21065 7592 23824 3000 300 33323 20785 94345 4000 200 28459 29307 201326 5000 100 19644 26621 265707 6000 9918 19010 248528 7000 2289 10255 183389 8000 528 3721 1061310 9000 122 1171 472311 10000 028 3472 180012 11000 006 096 62213 12000 001 026 20114 13000 000 007 06215 14000 000 002 01816 15000 000 000 00517 16000 000 000 00218 17000 000 000 000

10of 39

Figure F-3 Plot of a Triangular Hydrograph Routed Through Three Segments of Channel

Standard Step Method

Four cross sections along a reach are shown in Figures 7-17 7-18 7-19 7-20 Each crosssection is separated by 1524 m and is subdivided according to geometry and roughnessThe calculations shown in WS Elevation of 235 m represent one set of water-surfacecalculations An explanation of WS Elevation of 235 m follows the calculations Thecalculations represent the results of iterations at each section

Column 1 This column contains the cross section identification name

Column 2 This column contains the stream cross section station number

Column 3 The assumed water surface elevation must agree with the resulting computedwater surface elevation within plusmn 005 meters (or some other allowable tolerance) fortrial calculations to be successful

Column 4 This is the stage-discharge (rating) curve value for the first section thereafter itis the value calculated by adding ∆WS (Column 21) to the computed water surfaceelevation for the previous cross section

11of 39

Column 5 A is the cross-sectional area If the section is complex and has been subdividedinto several parts (eg left overbank channel and right overbank) then use one line ofthe form for each subsection and add to get the total area of cross section (At)

Column 6 This column contains the wetted perimeter If the section is subdivided thenuse one line for each subsection wetted perimeter

Column 7 R is the hydraulic radius Use the same procedure as for Column 5 if the sectionis complex but do not add subsection values

Column 8 n is Manningrsquos coefficient of channel roughness

Column 9 K is the conveyance and is determined with Equation 6-4 This column containsthe total conveyance for the cross section If the cross section is complex addsubsection K values to get the total conveyance (Kt)

Column 10 Kave the average conveyance for the reach is computed with Equation F-1

( )K = 12

K + Kave ds us

Equation F-1

Column 11 This column contains the friction slope at the current section and is computedusing Equation 67ndash8

S QKf =

2

Equation F-2

Column 12 The average friction slope is determined using Equation F-3

S QKf ave =

ave

2

Equation F-3

Column 13 L is the distance between cross-sections

Column 14 The energy loss due to friction (hf) through the reach is calculated usingEquation F-4

h = S Lf aveEquation F-4

Column 15 This column contains part of the expression relating distributed flow velocitiesto an average value (see Column 16) If the section is complex calculate one of thesevalues for each subsection and add all subsection values to get a total If one

12of 39

subsection is used you do not need Column 15 and the kinetic energy coefficient(Column 16) equals 10

Column 16 The kinetic energy coefficient (α) is calculated with Equation 6-10

Column 17 The average velocity (V) for the cross section is calculated with the continuityequation (Equation 6-1)

Column 18 This column contains the average velocity head corrected for flowdistribution

Column 19 This column contains the difference between the downstream and upstreamvelocity heads A positive value indicates velocity is increasing therefore use acontraction coefficient to account for ldquoother lossesrdquo A negative value indicates theexpansion coefficient should be used in calculating ldquoother lossesrdquo

Column 20 Calculate the ldquoother lossesrdquo by multiplying either the expansion coefficient(Ke) or contraction coefficient (Kc) by the absolute value of Column 18 That is forexpansion the change in velocity head will be negative but the head loss must bepositive ∆WS is the change in water surface elevation from the previous cross sectionIt is the algebraic sum of Columns 14 19 and 20

Storm Drain Design

Problem Statement

Given The working schematic Figure F-4 shows the layout of the roadway and crossstreets to be drained At the node indicated as A8 on the schematic an outflow from asmall storm drain system within the indicated shopping mall is accepted into thedepartmentrsquos system The storm drain system will outfall into a channel which isdirectly downstream of a culvert as indicated The culvert accommodates flow from a9065 hectare watershed

13of 39

Figure F-4 Layout of Drainage Areas and Inlets

14of 39

The hydrology and inlet data for this example are given in Hydrology and Inlet Informationtable This table includes the following for each drainage area

diams area

diams time of concentration

diams gutter slope

diams reciprocal of the cross slope

Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

A1 Curb 069010

055085 75 24 00050

A2 SGrate 006 070 20 32B1 Slot 011 085 32 24

00050C1 Curb 078

014050085 145 32 00060

A3 SGrate 010 070 20 32D1 Slot 014 085 41 32 00060E1 Slot 022 050 50 48 00065E2 Curb 042

011055085 135 48 00060

A4 JuncG1 Curb 041

011050085 90 32 00060

A5 SGrate 005 070 20 32F1 Slot 009 085 36 32 00060H1 Curb 008

006055085 60 48 00030

H2 Curb 012022

055085 65 48 00050

15of 39

(continued) Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

I1 Slot 032007

055085 80 48 00030

K1 Grate 066013

040085 150 48 00040

J1 Scurb 043021

060085 88 32

L1 Grate 030007

055085 177 48 00040

L2 Grate 024 085 36 48 00040L3 Grate 017 085 30 48 00040A6 JuncM1 SCurb 033 085 42 32A7 SGrate 004 070 20 32N1 SCurb 041 085 70 32Offsite 018

149070085 116

A8 JuncA9 Sgrate 012 070 34 32A10 Outfall

The Conduit Information table presents conduit design information such as soffitelevations and pipe lengths The General Given Information table contains generalinformation including

diams rainfall intensity factors

diams allowable ponded widths and

diams inlet requirements

16of 39

Conduit InformationIdentificationsUS DS

Length (m) US Soffit Elev (m)

A1 A2 20 256760B1 A2 20 256730A2 A3 100 256670C1 A3 20 256260D1 A3 20 256270A3 A4 20 256200E1 E2 90 256600E2 A4 20 256150A4 A5 75 256090G1 A5 20 255810F1 A5 25 255830A5 A6 75 255730J1 G1 25 255940H1 H2 125 255880I1 H2 60 255810H2 A6 57 255560L1 L2 95 256320K1 L2 55 256070L2 L3 86 255850L3 A6 20 255570A6 A7 56 255490M1 A7 20 255300N1 A7 18 255240A7 A8 60 255220A8 A9 104 254880A9 A10 40 254270

17of 39

General Given InformationDesign Frequency 5 years (20 chance of exceedance)Rainfall intensity factors e = 078 b = 1422 mm d = 82Curb height 015 mMinimum time of concentration 10 minutesMinimum curb inlet length 15 mMinimum slotted drain inlet length 6 mStandard grate inlets Parallel bars wtransverse rods

W = 05 m and L = 1 mGrate inlets on sag in median 05 m x 05 m square inlets bar area =

25 of grate area allowable pondeddepth = 06 m

Gutter depression for curb inlets 75 mmAllowable ponded width 36 m on Lone Star Blvd and 45 m on

Texas AveCurb inlets on sag slope = 00050 mm and 50 of

discharge on each side of inletOutfall tailwater elevation (2 yr) 254360 m

Required Design a storm drain system to accommodate the design discharge

Discussion The following example represents a single iteration of the design process It isone of a series of iterations that would require revision re-analysis and optimizationuntil a technically acceptable and economical design is accomplished

In a production design all design parameters and criteria must be met The illustration ofthe hydraulic grade line is for demonstration only Typically the hydraulic grade line isdeveloped as a last design step after the system has been optimized The next subsectionsoffer initial design process components and a design iteration procedure

Initial Design Process Components

The initial design process consists basically of the following three components

diams hydrology

diams inlet design and

diams conduit design

These components will be addressed individually However it is important to understandthat all three components must function together simultaneously You must evaluate thehydrology aspects with respect to both inlet design and conduit design

18of 39

Design Iteration Procedure

The following steps illustrate the activities in a single design iteration

Design Iteration ProcedureStep Action

Step 1 Prepare a system planStep 2 Base initial runoff computations on Rational Method and tabulate them in

Conduit Information tableStep 3 Locate inlets based on logic and hydraulic demand and configure the conduit

system

Step 1

Prepare a system plan

Prepare a system plan as discussed in Section 2 System Planning Effectively the exampleproblem is identified as delineated in the problem statement Ensure there are no ldquodeadrdquospots where the runoff has no outlet Establish the general location of inlets the laterals andthe trunk lines You must coordinate the logical location of the various system componentswith the component locations necessary to satisfy hydraulic demand In subsequent designiterations you may change any or all parts of the system configuration as necessary

a Establish the design parameters and criteriab Select materials and shapes to be usedc Assign the design frequencyd Identify utility intersections with respect to

bull locationbull typebull owner and probable disposition

e Identify detention facilities

19of 39

Step 2

Base initial runoff computations on the Rational Method and tabulate them in ConduitInformation table The first four columns of this tabulation are self-explanatory The totalCA as shown in the fifth column is computed by multiplying each incremental area by itscorresponding coefficient of runoff and summing these incremental products As anexample the total CA for drainage area A1 is computed as follows

Type Hectares C CAPaved 010 x 085 = 0085Residential 069 x 055 = 0380TOTALS 079 0465

20of 39

Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

A1 Curb 069010

055085

0465 75 100 14793 0191

A2 SGrate 006 070 0042 20 100 14793 0017B1 Slot 011 085 0094 32 100 14793 0038C1 Curb 078

014050085 0509 145 145 12451 0176

A3 SGrate 010 070 0070 20 100 14793 0029D1 Slot 014 085 0119 41 100 14793 0049E1 Slot 022 050 0110 50 100 14793 0045E2 Curb 042

011055085 0325 135 135 12896 0116

A4 Junc 000 000G1 Curb 041

011050085 0299 90 100 14793 0123

A5 SGrate 005 070 0035 20 100 14793 0014F1 Slot 009 085 0077 36 100 14793 0031H1 Curb 008

006055085 0095 60 100 14793 0039

H2 Curb 012022

055085 0253 65 100 14793 0104

I1 Slot 032007

055085 0236 80 100 14793 0097

21of 39

(continued) Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

K1 Grate 066013

040085 0375 150 150 12241 0127

J1 SCurb 043021

060085 0437 88 100 14793 0180

L1 Grate 030007

055085 0225 177 177 11234 0070

L2 Grate 024 085 0204 36 100 14793 0084L3 Grate 017 085 0145 30 100 14793 0059A6 Junc 000 000M1 SCurb 033 085 0281 42 100 14793 0115A7 SGrate 004 070 0028 20 100 14793 0012N1 SCurb 041 085 0349 70 100 14793 0143Offsite 018

149070085 1393 116 116 13852 0536

A8 Junc 000 000A9 SGrate 012 070 0084 34 100 14793 0035A10 Outfall 000 000

a In the Summary of Hydrologic Computations table note that the operating timeof concentration has a minimum value of 10 minutes (according to departmentpractice) However it is necessary to account for the smaller time of concentrationtherefore the actual time of concentration (minimum notwithstanding) is alsotabulated

b The rainfall intensity (I) is based on Equation F-5 where e = 078 b = 1422 and d= 82 For drainage area A1 the time of concentration is only 75 minutesTherefore using 10 minutes as a basis the rainfall intensity is calculated as 1479mmhr

If =b

tc + d( )e

Equation F-5where

If=rainfall intensity for frequency (mmhr)tc=time of concentration (min)e b d= empirical factors which are tabulated for each county in Texas

for frequencies of 2 5 10 25 50 and 100 years in Appendix Bc The peak discharge (Q) is determined by multiplying CA by I and 000278

(Equation F-6)

Q = C I A360

22of 39

Equation F-6whereQ =peak discharge (m3s)C =runoff coefficientI =rainfall intensity associated with a specific frequency (mmhr)A =area of the watershed (ha)

d For watershed A1 Q is 0191 m3sStep 3

Locate the inlets based on logic and hydraulic demand and configure the conduit systema Locate the inlets based on logic and hydraulic demand as outlined in Section 5

Storm Drain Inletsb Finally after locating the inlets (establishing the nodes for the storm drain system)

you can configure the conduit system

Tables F-7 to F-13 show the suggested tabular format for calculations in the design of theinlet system in this example Since the design process is iterative requiring adjustments andre-analysis until the design is optimized the examples shown are only a ldquosnapshotrdquo (or oneiteration) during the design process

Inlets On-Grade Explanation

C = =

=

C A

A

n nn

m

nn

m1

1

Equation F-7where

C=weighted runoff coefficientn=nth subaream=number of subareasCn=runoff coefficient for nth subareaAn=nth subarea size (ha)

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 7: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

7of 39

Example of Balanced Storm TabulationDuration

(min)Intensity(mmhr)

Cum Depth(mm)

Incr Depth(mm)

Time Block(mm)

Rainfall(mm)

15 14891 3723 3723 0-- 15 21230 10145 5072 1350 15-30 25645 7853 5890 817 30-45 32760 6478 6478 588 45-60 46275 5552 6940 462 60-75 81790 4882 7322 382 75-90 3723105 4371 7649 327 90-105 1350120 3968 7936 287 105-120 588135 3641 8192 256 120-135 382150 3369 8423 231 135-150 287165 3140 8635 212 150-165 231180 2943 8830 195 165-180 195

Figure F-2 Example of Hyetograph Using Balanced Storm Method

8of 39

Muskingum Method

The example shown in the Channel Routing Using the Muskingum Method table shows atriangular hydrograph routed through three 1000 meter reaches of channel The outflowhydrograph for each reach is used as the inflow for the next The channel has a lsquoKrsquo of 0278hours (1000 seconds) and an times of 02

Using Equations 5-30 5-31 and 5-32 with a time increment of 1000 sec

C11000 2 1000 0 2

2 1000 1 0 2 10000 23077= minus

minus +=( )( )

( )( )

C21000 2 1000 0 2

2 1000 1 0 2 1000053846= +

minus +=( )( )

( )( )

C32 1000 1 0 2 10002 1000 1 0 2 1000

0 23077= minus minusminus +

=( )( )( )( )

Check C1 + C2 + C3 = 023077 + 023077 + 053846 = 1

For time step two (t = 2) first reach

O2 = (023077)(200) + (053846)(0) + (023077)(0) = 4615 m3s

For time step 3 (t = 3)

O3 = (023077)(400) + (053846)(200) + (023077)(4615) = 21065 m3s

Repeating the process until the outflow hydrograph is complete The outflow hydrographfrom reach one becomes the inflow hydrograph for reach 2 and the process is repeated forreaches 2 and 3 Figure F-3 shows a plot of the hydrographs Since the outflow hydrographrepresents a displacement in distance as well as time the peak outflow does not coincidewith the receding limb of the inflow hydrograph

9of 39

Channel Routing Using the Muskingum MethodOutflow (m8s)Time

stepTime

(s)Inflow(m8s) Reach 1 Reach 2 Reach 3

1 0 0 0 0 02 1000 200 4615 1065 2463 2000 400 21065 7592 23824 3000 300 33323 20785 94345 4000 200 28459 29307 201326 5000 100 19644 26621 265707 6000 9918 19010 248528 7000 2289 10255 183389 8000 528 3721 1061310 9000 122 1171 472311 10000 028 3472 180012 11000 006 096 62213 12000 001 026 20114 13000 000 007 06215 14000 000 002 01816 15000 000 000 00517 16000 000 000 00218 17000 000 000 000

10of 39

Figure F-3 Plot of a Triangular Hydrograph Routed Through Three Segments of Channel

Standard Step Method

Four cross sections along a reach are shown in Figures 7-17 7-18 7-19 7-20 Each crosssection is separated by 1524 m and is subdivided according to geometry and roughnessThe calculations shown in WS Elevation of 235 m represent one set of water-surfacecalculations An explanation of WS Elevation of 235 m follows the calculations Thecalculations represent the results of iterations at each section

Column 1 This column contains the cross section identification name

Column 2 This column contains the stream cross section station number

Column 3 The assumed water surface elevation must agree with the resulting computedwater surface elevation within plusmn 005 meters (or some other allowable tolerance) fortrial calculations to be successful

Column 4 This is the stage-discharge (rating) curve value for the first section thereafter itis the value calculated by adding ∆WS (Column 21) to the computed water surfaceelevation for the previous cross section

11of 39

Column 5 A is the cross-sectional area If the section is complex and has been subdividedinto several parts (eg left overbank channel and right overbank) then use one line ofthe form for each subsection and add to get the total area of cross section (At)

Column 6 This column contains the wetted perimeter If the section is subdivided thenuse one line for each subsection wetted perimeter

Column 7 R is the hydraulic radius Use the same procedure as for Column 5 if the sectionis complex but do not add subsection values

Column 8 n is Manningrsquos coefficient of channel roughness

Column 9 K is the conveyance and is determined with Equation 6-4 This column containsthe total conveyance for the cross section If the cross section is complex addsubsection K values to get the total conveyance (Kt)

Column 10 Kave the average conveyance for the reach is computed with Equation F-1

( )K = 12

K + Kave ds us

Equation F-1

Column 11 This column contains the friction slope at the current section and is computedusing Equation 67ndash8

S QKf =

2

Equation F-2

Column 12 The average friction slope is determined using Equation F-3

S QKf ave =

ave

2

Equation F-3

Column 13 L is the distance between cross-sections

Column 14 The energy loss due to friction (hf) through the reach is calculated usingEquation F-4

h = S Lf aveEquation F-4

Column 15 This column contains part of the expression relating distributed flow velocitiesto an average value (see Column 16) If the section is complex calculate one of thesevalues for each subsection and add all subsection values to get a total If one

12of 39

subsection is used you do not need Column 15 and the kinetic energy coefficient(Column 16) equals 10

Column 16 The kinetic energy coefficient (α) is calculated with Equation 6-10

Column 17 The average velocity (V) for the cross section is calculated with the continuityequation (Equation 6-1)

Column 18 This column contains the average velocity head corrected for flowdistribution

Column 19 This column contains the difference between the downstream and upstreamvelocity heads A positive value indicates velocity is increasing therefore use acontraction coefficient to account for ldquoother lossesrdquo A negative value indicates theexpansion coefficient should be used in calculating ldquoother lossesrdquo

Column 20 Calculate the ldquoother lossesrdquo by multiplying either the expansion coefficient(Ke) or contraction coefficient (Kc) by the absolute value of Column 18 That is forexpansion the change in velocity head will be negative but the head loss must bepositive ∆WS is the change in water surface elevation from the previous cross sectionIt is the algebraic sum of Columns 14 19 and 20

Storm Drain Design

Problem Statement

Given The working schematic Figure F-4 shows the layout of the roadway and crossstreets to be drained At the node indicated as A8 on the schematic an outflow from asmall storm drain system within the indicated shopping mall is accepted into thedepartmentrsquos system The storm drain system will outfall into a channel which isdirectly downstream of a culvert as indicated The culvert accommodates flow from a9065 hectare watershed

13of 39

Figure F-4 Layout of Drainage Areas and Inlets

14of 39

The hydrology and inlet data for this example are given in Hydrology and Inlet Informationtable This table includes the following for each drainage area

diams area

diams time of concentration

diams gutter slope

diams reciprocal of the cross slope

Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

A1 Curb 069010

055085 75 24 00050

A2 SGrate 006 070 20 32B1 Slot 011 085 32 24

00050C1 Curb 078

014050085 145 32 00060

A3 SGrate 010 070 20 32D1 Slot 014 085 41 32 00060E1 Slot 022 050 50 48 00065E2 Curb 042

011055085 135 48 00060

A4 JuncG1 Curb 041

011050085 90 32 00060

A5 SGrate 005 070 20 32F1 Slot 009 085 36 32 00060H1 Curb 008

006055085 60 48 00030

H2 Curb 012022

055085 65 48 00050

15of 39

(continued) Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

I1 Slot 032007

055085 80 48 00030

K1 Grate 066013

040085 150 48 00040

J1 Scurb 043021

060085 88 32

L1 Grate 030007

055085 177 48 00040

L2 Grate 024 085 36 48 00040L3 Grate 017 085 30 48 00040A6 JuncM1 SCurb 033 085 42 32A7 SGrate 004 070 20 32N1 SCurb 041 085 70 32Offsite 018

149070085 116

A8 JuncA9 Sgrate 012 070 34 32A10 Outfall

The Conduit Information table presents conduit design information such as soffitelevations and pipe lengths The General Given Information table contains generalinformation including

diams rainfall intensity factors

diams allowable ponded widths and

diams inlet requirements

16of 39

Conduit InformationIdentificationsUS DS

Length (m) US Soffit Elev (m)

A1 A2 20 256760B1 A2 20 256730A2 A3 100 256670C1 A3 20 256260D1 A3 20 256270A3 A4 20 256200E1 E2 90 256600E2 A4 20 256150A4 A5 75 256090G1 A5 20 255810F1 A5 25 255830A5 A6 75 255730J1 G1 25 255940H1 H2 125 255880I1 H2 60 255810H2 A6 57 255560L1 L2 95 256320K1 L2 55 256070L2 L3 86 255850L3 A6 20 255570A6 A7 56 255490M1 A7 20 255300N1 A7 18 255240A7 A8 60 255220A8 A9 104 254880A9 A10 40 254270

17of 39

General Given InformationDesign Frequency 5 years (20 chance of exceedance)Rainfall intensity factors e = 078 b = 1422 mm d = 82Curb height 015 mMinimum time of concentration 10 minutesMinimum curb inlet length 15 mMinimum slotted drain inlet length 6 mStandard grate inlets Parallel bars wtransverse rods

W = 05 m and L = 1 mGrate inlets on sag in median 05 m x 05 m square inlets bar area =

25 of grate area allowable pondeddepth = 06 m

Gutter depression for curb inlets 75 mmAllowable ponded width 36 m on Lone Star Blvd and 45 m on

Texas AveCurb inlets on sag slope = 00050 mm and 50 of

discharge on each side of inletOutfall tailwater elevation (2 yr) 254360 m

Required Design a storm drain system to accommodate the design discharge

Discussion The following example represents a single iteration of the design process It isone of a series of iterations that would require revision re-analysis and optimizationuntil a technically acceptable and economical design is accomplished

In a production design all design parameters and criteria must be met The illustration ofthe hydraulic grade line is for demonstration only Typically the hydraulic grade line isdeveloped as a last design step after the system has been optimized The next subsectionsoffer initial design process components and a design iteration procedure

Initial Design Process Components

The initial design process consists basically of the following three components

diams hydrology

diams inlet design and

diams conduit design

These components will be addressed individually However it is important to understandthat all three components must function together simultaneously You must evaluate thehydrology aspects with respect to both inlet design and conduit design

18of 39

Design Iteration Procedure

The following steps illustrate the activities in a single design iteration

Design Iteration ProcedureStep Action

Step 1 Prepare a system planStep 2 Base initial runoff computations on Rational Method and tabulate them in

Conduit Information tableStep 3 Locate inlets based on logic and hydraulic demand and configure the conduit

system

Step 1

Prepare a system plan

Prepare a system plan as discussed in Section 2 System Planning Effectively the exampleproblem is identified as delineated in the problem statement Ensure there are no ldquodeadrdquospots where the runoff has no outlet Establish the general location of inlets the laterals andthe trunk lines You must coordinate the logical location of the various system componentswith the component locations necessary to satisfy hydraulic demand In subsequent designiterations you may change any or all parts of the system configuration as necessary

a Establish the design parameters and criteriab Select materials and shapes to be usedc Assign the design frequencyd Identify utility intersections with respect to

bull locationbull typebull owner and probable disposition

e Identify detention facilities

19of 39

Step 2

Base initial runoff computations on the Rational Method and tabulate them in ConduitInformation table The first four columns of this tabulation are self-explanatory The totalCA as shown in the fifth column is computed by multiplying each incremental area by itscorresponding coefficient of runoff and summing these incremental products As anexample the total CA for drainage area A1 is computed as follows

Type Hectares C CAPaved 010 x 085 = 0085Residential 069 x 055 = 0380TOTALS 079 0465

20of 39

Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

A1 Curb 069010

055085

0465 75 100 14793 0191

A2 SGrate 006 070 0042 20 100 14793 0017B1 Slot 011 085 0094 32 100 14793 0038C1 Curb 078

014050085 0509 145 145 12451 0176

A3 SGrate 010 070 0070 20 100 14793 0029D1 Slot 014 085 0119 41 100 14793 0049E1 Slot 022 050 0110 50 100 14793 0045E2 Curb 042

011055085 0325 135 135 12896 0116

A4 Junc 000 000G1 Curb 041

011050085 0299 90 100 14793 0123

A5 SGrate 005 070 0035 20 100 14793 0014F1 Slot 009 085 0077 36 100 14793 0031H1 Curb 008

006055085 0095 60 100 14793 0039

H2 Curb 012022

055085 0253 65 100 14793 0104

I1 Slot 032007

055085 0236 80 100 14793 0097

21of 39

(continued) Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

K1 Grate 066013

040085 0375 150 150 12241 0127

J1 SCurb 043021

060085 0437 88 100 14793 0180

L1 Grate 030007

055085 0225 177 177 11234 0070

L2 Grate 024 085 0204 36 100 14793 0084L3 Grate 017 085 0145 30 100 14793 0059A6 Junc 000 000M1 SCurb 033 085 0281 42 100 14793 0115A7 SGrate 004 070 0028 20 100 14793 0012N1 SCurb 041 085 0349 70 100 14793 0143Offsite 018

149070085 1393 116 116 13852 0536

A8 Junc 000 000A9 SGrate 012 070 0084 34 100 14793 0035A10 Outfall 000 000

a In the Summary of Hydrologic Computations table note that the operating timeof concentration has a minimum value of 10 minutes (according to departmentpractice) However it is necessary to account for the smaller time of concentrationtherefore the actual time of concentration (minimum notwithstanding) is alsotabulated

b The rainfall intensity (I) is based on Equation F-5 where e = 078 b = 1422 and d= 82 For drainage area A1 the time of concentration is only 75 minutesTherefore using 10 minutes as a basis the rainfall intensity is calculated as 1479mmhr

If =b

tc + d( )e

Equation F-5where

If=rainfall intensity for frequency (mmhr)tc=time of concentration (min)e b d= empirical factors which are tabulated for each county in Texas

for frequencies of 2 5 10 25 50 and 100 years in Appendix Bc The peak discharge (Q) is determined by multiplying CA by I and 000278

(Equation F-6)

Q = C I A360

22of 39

Equation F-6whereQ =peak discharge (m3s)C =runoff coefficientI =rainfall intensity associated with a specific frequency (mmhr)A =area of the watershed (ha)

d For watershed A1 Q is 0191 m3sStep 3

Locate the inlets based on logic and hydraulic demand and configure the conduit systema Locate the inlets based on logic and hydraulic demand as outlined in Section 5

Storm Drain Inletsb Finally after locating the inlets (establishing the nodes for the storm drain system)

you can configure the conduit system

Tables F-7 to F-13 show the suggested tabular format for calculations in the design of theinlet system in this example Since the design process is iterative requiring adjustments andre-analysis until the design is optimized the examples shown are only a ldquosnapshotrdquo (or oneiteration) during the design process

Inlets On-Grade Explanation

C = =

=

C A

A

n nn

m

nn

m1

1

Equation F-7where

C=weighted runoff coefficientn=nth subaream=number of subareasCn=runoff coefficient for nth subareaAn=nth subarea size (ha)

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 8: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

8of 39

Muskingum Method

The example shown in the Channel Routing Using the Muskingum Method table shows atriangular hydrograph routed through three 1000 meter reaches of channel The outflowhydrograph for each reach is used as the inflow for the next The channel has a lsquoKrsquo of 0278hours (1000 seconds) and an times of 02

Using Equations 5-30 5-31 and 5-32 with a time increment of 1000 sec

C11000 2 1000 0 2

2 1000 1 0 2 10000 23077= minus

minus +=( )( )

( )( )

C21000 2 1000 0 2

2 1000 1 0 2 1000053846= +

minus +=( )( )

( )( )

C32 1000 1 0 2 10002 1000 1 0 2 1000

0 23077= minus minusminus +

=( )( )( )( )

Check C1 + C2 + C3 = 023077 + 023077 + 053846 = 1

For time step two (t = 2) first reach

O2 = (023077)(200) + (053846)(0) + (023077)(0) = 4615 m3s

For time step 3 (t = 3)

O3 = (023077)(400) + (053846)(200) + (023077)(4615) = 21065 m3s

Repeating the process until the outflow hydrograph is complete The outflow hydrographfrom reach one becomes the inflow hydrograph for reach 2 and the process is repeated forreaches 2 and 3 Figure F-3 shows a plot of the hydrographs Since the outflow hydrographrepresents a displacement in distance as well as time the peak outflow does not coincidewith the receding limb of the inflow hydrograph

9of 39

Channel Routing Using the Muskingum MethodOutflow (m8s)Time

stepTime

(s)Inflow(m8s) Reach 1 Reach 2 Reach 3

1 0 0 0 0 02 1000 200 4615 1065 2463 2000 400 21065 7592 23824 3000 300 33323 20785 94345 4000 200 28459 29307 201326 5000 100 19644 26621 265707 6000 9918 19010 248528 7000 2289 10255 183389 8000 528 3721 1061310 9000 122 1171 472311 10000 028 3472 180012 11000 006 096 62213 12000 001 026 20114 13000 000 007 06215 14000 000 002 01816 15000 000 000 00517 16000 000 000 00218 17000 000 000 000

10of 39

Figure F-3 Plot of a Triangular Hydrograph Routed Through Three Segments of Channel

Standard Step Method

Four cross sections along a reach are shown in Figures 7-17 7-18 7-19 7-20 Each crosssection is separated by 1524 m and is subdivided according to geometry and roughnessThe calculations shown in WS Elevation of 235 m represent one set of water-surfacecalculations An explanation of WS Elevation of 235 m follows the calculations Thecalculations represent the results of iterations at each section

Column 1 This column contains the cross section identification name

Column 2 This column contains the stream cross section station number

Column 3 The assumed water surface elevation must agree with the resulting computedwater surface elevation within plusmn 005 meters (or some other allowable tolerance) fortrial calculations to be successful

Column 4 This is the stage-discharge (rating) curve value for the first section thereafter itis the value calculated by adding ∆WS (Column 21) to the computed water surfaceelevation for the previous cross section

11of 39

Column 5 A is the cross-sectional area If the section is complex and has been subdividedinto several parts (eg left overbank channel and right overbank) then use one line ofthe form for each subsection and add to get the total area of cross section (At)

Column 6 This column contains the wetted perimeter If the section is subdivided thenuse one line for each subsection wetted perimeter

Column 7 R is the hydraulic radius Use the same procedure as for Column 5 if the sectionis complex but do not add subsection values

Column 8 n is Manningrsquos coefficient of channel roughness

Column 9 K is the conveyance and is determined with Equation 6-4 This column containsthe total conveyance for the cross section If the cross section is complex addsubsection K values to get the total conveyance (Kt)

Column 10 Kave the average conveyance for the reach is computed with Equation F-1

( )K = 12

K + Kave ds us

Equation F-1

Column 11 This column contains the friction slope at the current section and is computedusing Equation 67ndash8

S QKf =

2

Equation F-2

Column 12 The average friction slope is determined using Equation F-3

S QKf ave =

ave

2

Equation F-3

Column 13 L is the distance between cross-sections

Column 14 The energy loss due to friction (hf) through the reach is calculated usingEquation F-4

h = S Lf aveEquation F-4

Column 15 This column contains part of the expression relating distributed flow velocitiesto an average value (see Column 16) If the section is complex calculate one of thesevalues for each subsection and add all subsection values to get a total If one

12of 39

subsection is used you do not need Column 15 and the kinetic energy coefficient(Column 16) equals 10

Column 16 The kinetic energy coefficient (α) is calculated with Equation 6-10

Column 17 The average velocity (V) for the cross section is calculated with the continuityequation (Equation 6-1)

Column 18 This column contains the average velocity head corrected for flowdistribution

Column 19 This column contains the difference between the downstream and upstreamvelocity heads A positive value indicates velocity is increasing therefore use acontraction coefficient to account for ldquoother lossesrdquo A negative value indicates theexpansion coefficient should be used in calculating ldquoother lossesrdquo

Column 20 Calculate the ldquoother lossesrdquo by multiplying either the expansion coefficient(Ke) or contraction coefficient (Kc) by the absolute value of Column 18 That is forexpansion the change in velocity head will be negative but the head loss must bepositive ∆WS is the change in water surface elevation from the previous cross sectionIt is the algebraic sum of Columns 14 19 and 20

Storm Drain Design

Problem Statement

Given The working schematic Figure F-4 shows the layout of the roadway and crossstreets to be drained At the node indicated as A8 on the schematic an outflow from asmall storm drain system within the indicated shopping mall is accepted into thedepartmentrsquos system The storm drain system will outfall into a channel which isdirectly downstream of a culvert as indicated The culvert accommodates flow from a9065 hectare watershed

13of 39

Figure F-4 Layout of Drainage Areas and Inlets

14of 39

The hydrology and inlet data for this example are given in Hydrology and Inlet Informationtable This table includes the following for each drainage area

diams area

diams time of concentration

diams gutter slope

diams reciprocal of the cross slope

Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

A1 Curb 069010

055085 75 24 00050

A2 SGrate 006 070 20 32B1 Slot 011 085 32 24

00050C1 Curb 078

014050085 145 32 00060

A3 SGrate 010 070 20 32D1 Slot 014 085 41 32 00060E1 Slot 022 050 50 48 00065E2 Curb 042

011055085 135 48 00060

A4 JuncG1 Curb 041

011050085 90 32 00060

A5 SGrate 005 070 20 32F1 Slot 009 085 36 32 00060H1 Curb 008

006055085 60 48 00030

H2 Curb 012022

055085 65 48 00050

15of 39

(continued) Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

I1 Slot 032007

055085 80 48 00030

K1 Grate 066013

040085 150 48 00040

J1 Scurb 043021

060085 88 32

L1 Grate 030007

055085 177 48 00040

L2 Grate 024 085 36 48 00040L3 Grate 017 085 30 48 00040A6 JuncM1 SCurb 033 085 42 32A7 SGrate 004 070 20 32N1 SCurb 041 085 70 32Offsite 018

149070085 116

A8 JuncA9 Sgrate 012 070 34 32A10 Outfall

The Conduit Information table presents conduit design information such as soffitelevations and pipe lengths The General Given Information table contains generalinformation including

diams rainfall intensity factors

diams allowable ponded widths and

diams inlet requirements

16of 39

Conduit InformationIdentificationsUS DS

Length (m) US Soffit Elev (m)

A1 A2 20 256760B1 A2 20 256730A2 A3 100 256670C1 A3 20 256260D1 A3 20 256270A3 A4 20 256200E1 E2 90 256600E2 A4 20 256150A4 A5 75 256090G1 A5 20 255810F1 A5 25 255830A5 A6 75 255730J1 G1 25 255940H1 H2 125 255880I1 H2 60 255810H2 A6 57 255560L1 L2 95 256320K1 L2 55 256070L2 L3 86 255850L3 A6 20 255570A6 A7 56 255490M1 A7 20 255300N1 A7 18 255240A7 A8 60 255220A8 A9 104 254880A9 A10 40 254270

17of 39

General Given InformationDesign Frequency 5 years (20 chance of exceedance)Rainfall intensity factors e = 078 b = 1422 mm d = 82Curb height 015 mMinimum time of concentration 10 minutesMinimum curb inlet length 15 mMinimum slotted drain inlet length 6 mStandard grate inlets Parallel bars wtransverse rods

W = 05 m and L = 1 mGrate inlets on sag in median 05 m x 05 m square inlets bar area =

25 of grate area allowable pondeddepth = 06 m

Gutter depression for curb inlets 75 mmAllowable ponded width 36 m on Lone Star Blvd and 45 m on

Texas AveCurb inlets on sag slope = 00050 mm and 50 of

discharge on each side of inletOutfall tailwater elevation (2 yr) 254360 m

Required Design a storm drain system to accommodate the design discharge

Discussion The following example represents a single iteration of the design process It isone of a series of iterations that would require revision re-analysis and optimizationuntil a technically acceptable and economical design is accomplished

In a production design all design parameters and criteria must be met The illustration ofthe hydraulic grade line is for demonstration only Typically the hydraulic grade line isdeveloped as a last design step after the system has been optimized The next subsectionsoffer initial design process components and a design iteration procedure

Initial Design Process Components

The initial design process consists basically of the following three components

diams hydrology

diams inlet design and

diams conduit design

These components will be addressed individually However it is important to understandthat all three components must function together simultaneously You must evaluate thehydrology aspects with respect to both inlet design and conduit design

18of 39

Design Iteration Procedure

The following steps illustrate the activities in a single design iteration

Design Iteration ProcedureStep Action

Step 1 Prepare a system planStep 2 Base initial runoff computations on Rational Method and tabulate them in

Conduit Information tableStep 3 Locate inlets based on logic and hydraulic demand and configure the conduit

system

Step 1

Prepare a system plan

Prepare a system plan as discussed in Section 2 System Planning Effectively the exampleproblem is identified as delineated in the problem statement Ensure there are no ldquodeadrdquospots where the runoff has no outlet Establish the general location of inlets the laterals andthe trunk lines You must coordinate the logical location of the various system componentswith the component locations necessary to satisfy hydraulic demand In subsequent designiterations you may change any or all parts of the system configuration as necessary

a Establish the design parameters and criteriab Select materials and shapes to be usedc Assign the design frequencyd Identify utility intersections with respect to

bull locationbull typebull owner and probable disposition

e Identify detention facilities

19of 39

Step 2

Base initial runoff computations on the Rational Method and tabulate them in ConduitInformation table The first four columns of this tabulation are self-explanatory The totalCA as shown in the fifth column is computed by multiplying each incremental area by itscorresponding coefficient of runoff and summing these incremental products As anexample the total CA for drainage area A1 is computed as follows

Type Hectares C CAPaved 010 x 085 = 0085Residential 069 x 055 = 0380TOTALS 079 0465

20of 39

Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

A1 Curb 069010

055085

0465 75 100 14793 0191

A2 SGrate 006 070 0042 20 100 14793 0017B1 Slot 011 085 0094 32 100 14793 0038C1 Curb 078

014050085 0509 145 145 12451 0176

A3 SGrate 010 070 0070 20 100 14793 0029D1 Slot 014 085 0119 41 100 14793 0049E1 Slot 022 050 0110 50 100 14793 0045E2 Curb 042

011055085 0325 135 135 12896 0116

A4 Junc 000 000G1 Curb 041

011050085 0299 90 100 14793 0123

A5 SGrate 005 070 0035 20 100 14793 0014F1 Slot 009 085 0077 36 100 14793 0031H1 Curb 008

006055085 0095 60 100 14793 0039

H2 Curb 012022

055085 0253 65 100 14793 0104

I1 Slot 032007

055085 0236 80 100 14793 0097

21of 39

(continued) Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

K1 Grate 066013

040085 0375 150 150 12241 0127

J1 SCurb 043021

060085 0437 88 100 14793 0180

L1 Grate 030007

055085 0225 177 177 11234 0070

L2 Grate 024 085 0204 36 100 14793 0084L3 Grate 017 085 0145 30 100 14793 0059A6 Junc 000 000M1 SCurb 033 085 0281 42 100 14793 0115A7 SGrate 004 070 0028 20 100 14793 0012N1 SCurb 041 085 0349 70 100 14793 0143Offsite 018

149070085 1393 116 116 13852 0536

A8 Junc 000 000A9 SGrate 012 070 0084 34 100 14793 0035A10 Outfall 000 000

a In the Summary of Hydrologic Computations table note that the operating timeof concentration has a minimum value of 10 minutes (according to departmentpractice) However it is necessary to account for the smaller time of concentrationtherefore the actual time of concentration (minimum notwithstanding) is alsotabulated

b The rainfall intensity (I) is based on Equation F-5 where e = 078 b = 1422 and d= 82 For drainage area A1 the time of concentration is only 75 minutesTherefore using 10 minutes as a basis the rainfall intensity is calculated as 1479mmhr

If =b

tc + d( )e

Equation F-5where

If=rainfall intensity for frequency (mmhr)tc=time of concentration (min)e b d= empirical factors which are tabulated for each county in Texas

for frequencies of 2 5 10 25 50 and 100 years in Appendix Bc The peak discharge (Q) is determined by multiplying CA by I and 000278

(Equation F-6)

Q = C I A360

22of 39

Equation F-6whereQ =peak discharge (m3s)C =runoff coefficientI =rainfall intensity associated with a specific frequency (mmhr)A =area of the watershed (ha)

d For watershed A1 Q is 0191 m3sStep 3

Locate the inlets based on logic and hydraulic demand and configure the conduit systema Locate the inlets based on logic and hydraulic demand as outlined in Section 5

Storm Drain Inletsb Finally after locating the inlets (establishing the nodes for the storm drain system)

you can configure the conduit system

Tables F-7 to F-13 show the suggested tabular format for calculations in the design of theinlet system in this example Since the design process is iterative requiring adjustments andre-analysis until the design is optimized the examples shown are only a ldquosnapshotrdquo (or oneiteration) during the design process

Inlets On-Grade Explanation

C = =

=

C A

A

n nn

m

nn

m1

1

Equation F-7where

C=weighted runoff coefficientn=nth subaream=number of subareasCn=runoff coefficient for nth subareaAn=nth subarea size (ha)

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 9: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

9of 39

Channel Routing Using the Muskingum MethodOutflow (m8s)Time

stepTime

(s)Inflow(m8s) Reach 1 Reach 2 Reach 3

1 0 0 0 0 02 1000 200 4615 1065 2463 2000 400 21065 7592 23824 3000 300 33323 20785 94345 4000 200 28459 29307 201326 5000 100 19644 26621 265707 6000 9918 19010 248528 7000 2289 10255 183389 8000 528 3721 1061310 9000 122 1171 472311 10000 028 3472 180012 11000 006 096 62213 12000 001 026 20114 13000 000 007 06215 14000 000 002 01816 15000 000 000 00517 16000 000 000 00218 17000 000 000 000

10of 39

Figure F-3 Plot of a Triangular Hydrograph Routed Through Three Segments of Channel

Standard Step Method

Four cross sections along a reach are shown in Figures 7-17 7-18 7-19 7-20 Each crosssection is separated by 1524 m and is subdivided according to geometry and roughnessThe calculations shown in WS Elevation of 235 m represent one set of water-surfacecalculations An explanation of WS Elevation of 235 m follows the calculations Thecalculations represent the results of iterations at each section

Column 1 This column contains the cross section identification name

Column 2 This column contains the stream cross section station number

Column 3 The assumed water surface elevation must agree with the resulting computedwater surface elevation within plusmn 005 meters (or some other allowable tolerance) fortrial calculations to be successful

Column 4 This is the stage-discharge (rating) curve value for the first section thereafter itis the value calculated by adding ∆WS (Column 21) to the computed water surfaceelevation for the previous cross section

11of 39

Column 5 A is the cross-sectional area If the section is complex and has been subdividedinto several parts (eg left overbank channel and right overbank) then use one line ofthe form for each subsection and add to get the total area of cross section (At)

Column 6 This column contains the wetted perimeter If the section is subdivided thenuse one line for each subsection wetted perimeter

Column 7 R is the hydraulic radius Use the same procedure as for Column 5 if the sectionis complex but do not add subsection values

Column 8 n is Manningrsquos coefficient of channel roughness

Column 9 K is the conveyance and is determined with Equation 6-4 This column containsthe total conveyance for the cross section If the cross section is complex addsubsection K values to get the total conveyance (Kt)

Column 10 Kave the average conveyance for the reach is computed with Equation F-1

( )K = 12

K + Kave ds us

Equation F-1

Column 11 This column contains the friction slope at the current section and is computedusing Equation 67ndash8

S QKf =

2

Equation F-2

Column 12 The average friction slope is determined using Equation F-3

S QKf ave =

ave

2

Equation F-3

Column 13 L is the distance between cross-sections

Column 14 The energy loss due to friction (hf) through the reach is calculated usingEquation F-4

h = S Lf aveEquation F-4

Column 15 This column contains part of the expression relating distributed flow velocitiesto an average value (see Column 16) If the section is complex calculate one of thesevalues for each subsection and add all subsection values to get a total If one

12of 39

subsection is used you do not need Column 15 and the kinetic energy coefficient(Column 16) equals 10

Column 16 The kinetic energy coefficient (α) is calculated with Equation 6-10

Column 17 The average velocity (V) for the cross section is calculated with the continuityequation (Equation 6-1)

Column 18 This column contains the average velocity head corrected for flowdistribution

Column 19 This column contains the difference between the downstream and upstreamvelocity heads A positive value indicates velocity is increasing therefore use acontraction coefficient to account for ldquoother lossesrdquo A negative value indicates theexpansion coefficient should be used in calculating ldquoother lossesrdquo

Column 20 Calculate the ldquoother lossesrdquo by multiplying either the expansion coefficient(Ke) or contraction coefficient (Kc) by the absolute value of Column 18 That is forexpansion the change in velocity head will be negative but the head loss must bepositive ∆WS is the change in water surface elevation from the previous cross sectionIt is the algebraic sum of Columns 14 19 and 20

Storm Drain Design

Problem Statement

Given The working schematic Figure F-4 shows the layout of the roadway and crossstreets to be drained At the node indicated as A8 on the schematic an outflow from asmall storm drain system within the indicated shopping mall is accepted into thedepartmentrsquos system The storm drain system will outfall into a channel which isdirectly downstream of a culvert as indicated The culvert accommodates flow from a9065 hectare watershed

13of 39

Figure F-4 Layout of Drainage Areas and Inlets

14of 39

The hydrology and inlet data for this example are given in Hydrology and Inlet Informationtable This table includes the following for each drainage area

diams area

diams time of concentration

diams gutter slope

diams reciprocal of the cross slope

Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

A1 Curb 069010

055085 75 24 00050

A2 SGrate 006 070 20 32B1 Slot 011 085 32 24

00050C1 Curb 078

014050085 145 32 00060

A3 SGrate 010 070 20 32D1 Slot 014 085 41 32 00060E1 Slot 022 050 50 48 00065E2 Curb 042

011055085 135 48 00060

A4 JuncG1 Curb 041

011050085 90 32 00060

A5 SGrate 005 070 20 32F1 Slot 009 085 36 32 00060H1 Curb 008

006055085 60 48 00030

H2 Curb 012022

055085 65 48 00050

15of 39

(continued) Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

I1 Slot 032007

055085 80 48 00030

K1 Grate 066013

040085 150 48 00040

J1 Scurb 043021

060085 88 32

L1 Grate 030007

055085 177 48 00040

L2 Grate 024 085 36 48 00040L3 Grate 017 085 30 48 00040A6 JuncM1 SCurb 033 085 42 32A7 SGrate 004 070 20 32N1 SCurb 041 085 70 32Offsite 018

149070085 116

A8 JuncA9 Sgrate 012 070 34 32A10 Outfall

The Conduit Information table presents conduit design information such as soffitelevations and pipe lengths The General Given Information table contains generalinformation including

diams rainfall intensity factors

diams allowable ponded widths and

diams inlet requirements

16of 39

Conduit InformationIdentificationsUS DS

Length (m) US Soffit Elev (m)

A1 A2 20 256760B1 A2 20 256730A2 A3 100 256670C1 A3 20 256260D1 A3 20 256270A3 A4 20 256200E1 E2 90 256600E2 A4 20 256150A4 A5 75 256090G1 A5 20 255810F1 A5 25 255830A5 A6 75 255730J1 G1 25 255940H1 H2 125 255880I1 H2 60 255810H2 A6 57 255560L1 L2 95 256320K1 L2 55 256070L2 L3 86 255850L3 A6 20 255570A6 A7 56 255490M1 A7 20 255300N1 A7 18 255240A7 A8 60 255220A8 A9 104 254880A9 A10 40 254270

17of 39

General Given InformationDesign Frequency 5 years (20 chance of exceedance)Rainfall intensity factors e = 078 b = 1422 mm d = 82Curb height 015 mMinimum time of concentration 10 minutesMinimum curb inlet length 15 mMinimum slotted drain inlet length 6 mStandard grate inlets Parallel bars wtransverse rods

W = 05 m and L = 1 mGrate inlets on sag in median 05 m x 05 m square inlets bar area =

25 of grate area allowable pondeddepth = 06 m

Gutter depression for curb inlets 75 mmAllowable ponded width 36 m on Lone Star Blvd and 45 m on

Texas AveCurb inlets on sag slope = 00050 mm and 50 of

discharge on each side of inletOutfall tailwater elevation (2 yr) 254360 m

Required Design a storm drain system to accommodate the design discharge

Discussion The following example represents a single iteration of the design process It isone of a series of iterations that would require revision re-analysis and optimizationuntil a technically acceptable and economical design is accomplished

In a production design all design parameters and criteria must be met The illustration ofthe hydraulic grade line is for demonstration only Typically the hydraulic grade line isdeveloped as a last design step after the system has been optimized The next subsectionsoffer initial design process components and a design iteration procedure

Initial Design Process Components

The initial design process consists basically of the following three components

diams hydrology

diams inlet design and

diams conduit design

These components will be addressed individually However it is important to understandthat all three components must function together simultaneously You must evaluate thehydrology aspects with respect to both inlet design and conduit design

18of 39

Design Iteration Procedure

The following steps illustrate the activities in a single design iteration

Design Iteration ProcedureStep Action

Step 1 Prepare a system planStep 2 Base initial runoff computations on Rational Method and tabulate them in

Conduit Information tableStep 3 Locate inlets based on logic and hydraulic demand and configure the conduit

system

Step 1

Prepare a system plan

Prepare a system plan as discussed in Section 2 System Planning Effectively the exampleproblem is identified as delineated in the problem statement Ensure there are no ldquodeadrdquospots where the runoff has no outlet Establish the general location of inlets the laterals andthe trunk lines You must coordinate the logical location of the various system componentswith the component locations necessary to satisfy hydraulic demand In subsequent designiterations you may change any or all parts of the system configuration as necessary

a Establish the design parameters and criteriab Select materials and shapes to be usedc Assign the design frequencyd Identify utility intersections with respect to

bull locationbull typebull owner and probable disposition

e Identify detention facilities

19of 39

Step 2

Base initial runoff computations on the Rational Method and tabulate them in ConduitInformation table The first four columns of this tabulation are self-explanatory The totalCA as shown in the fifth column is computed by multiplying each incremental area by itscorresponding coefficient of runoff and summing these incremental products As anexample the total CA for drainage area A1 is computed as follows

Type Hectares C CAPaved 010 x 085 = 0085Residential 069 x 055 = 0380TOTALS 079 0465

20of 39

Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

A1 Curb 069010

055085

0465 75 100 14793 0191

A2 SGrate 006 070 0042 20 100 14793 0017B1 Slot 011 085 0094 32 100 14793 0038C1 Curb 078

014050085 0509 145 145 12451 0176

A3 SGrate 010 070 0070 20 100 14793 0029D1 Slot 014 085 0119 41 100 14793 0049E1 Slot 022 050 0110 50 100 14793 0045E2 Curb 042

011055085 0325 135 135 12896 0116

A4 Junc 000 000G1 Curb 041

011050085 0299 90 100 14793 0123

A5 SGrate 005 070 0035 20 100 14793 0014F1 Slot 009 085 0077 36 100 14793 0031H1 Curb 008

006055085 0095 60 100 14793 0039

H2 Curb 012022

055085 0253 65 100 14793 0104

I1 Slot 032007

055085 0236 80 100 14793 0097

21of 39

(continued) Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

K1 Grate 066013

040085 0375 150 150 12241 0127

J1 SCurb 043021

060085 0437 88 100 14793 0180

L1 Grate 030007

055085 0225 177 177 11234 0070

L2 Grate 024 085 0204 36 100 14793 0084L3 Grate 017 085 0145 30 100 14793 0059A6 Junc 000 000M1 SCurb 033 085 0281 42 100 14793 0115A7 SGrate 004 070 0028 20 100 14793 0012N1 SCurb 041 085 0349 70 100 14793 0143Offsite 018

149070085 1393 116 116 13852 0536

A8 Junc 000 000A9 SGrate 012 070 0084 34 100 14793 0035A10 Outfall 000 000

a In the Summary of Hydrologic Computations table note that the operating timeof concentration has a minimum value of 10 minutes (according to departmentpractice) However it is necessary to account for the smaller time of concentrationtherefore the actual time of concentration (minimum notwithstanding) is alsotabulated

b The rainfall intensity (I) is based on Equation F-5 where e = 078 b = 1422 and d= 82 For drainage area A1 the time of concentration is only 75 minutesTherefore using 10 minutes as a basis the rainfall intensity is calculated as 1479mmhr

If =b

tc + d( )e

Equation F-5where

If=rainfall intensity for frequency (mmhr)tc=time of concentration (min)e b d= empirical factors which are tabulated for each county in Texas

for frequencies of 2 5 10 25 50 and 100 years in Appendix Bc The peak discharge (Q) is determined by multiplying CA by I and 000278

(Equation F-6)

Q = C I A360

22of 39

Equation F-6whereQ =peak discharge (m3s)C =runoff coefficientI =rainfall intensity associated with a specific frequency (mmhr)A =area of the watershed (ha)

d For watershed A1 Q is 0191 m3sStep 3

Locate the inlets based on logic and hydraulic demand and configure the conduit systema Locate the inlets based on logic and hydraulic demand as outlined in Section 5

Storm Drain Inletsb Finally after locating the inlets (establishing the nodes for the storm drain system)

you can configure the conduit system

Tables F-7 to F-13 show the suggested tabular format for calculations in the design of theinlet system in this example Since the design process is iterative requiring adjustments andre-analysis until the design is optimized the examples shown are only a ldquosnapshotrdquo (or oneiteration) during the design process

Inlets On-Grade Explanation

C = =

=

C A

A

n nn

m

nn

m1

1

Equation F-7where

C=weighted runoff coefficientn=nth subaream=number of subareasCn=runoff coefficient for nth subareaAn=nth subarea size (ha)

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 10: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

10of 39

Figure F-3 Plot of a Triangular Hydrograph Routed Through Three Segments of Channel

Standard Step Method

Four cross sections along a reach are shown in Figures 7-17 7-18 7-19 7-20 Each crosssection is separated by 1524 m and is subdivided according to geometry and roughnessThe calculations shown in WS Elevation of 235 m represent one set of water-surfacecalculations An explanation of WS Elevation of 235 m follows the calculations Thecalculations represent the results of iterations at each section

Column 1 This column contains the cross section identification name

Column 2 This column contains the stream cross section station number

Column 3 The assumed water surface elevation must agree with the resulting computedwater surface elevation within plusmn 005 meters (or some other allowable tolerance) fortrial calculations to be successful

Column 4 This is the stage-discharge (rating) curve value for the first section thereafter itis the value calculated by adding ∆WS (Column 21) to the computed water surfaceelevation for the previous cross section

11of 39

Column 5 A is the cross-sectional area If the section is complex and has been subdividedinto several parts (eg left overbank channel and right overbank) then use one line ofthe form for each subsection and add to get the total area of cross section (At)

Column 6 This column contains the wetted perimeter If the section is subdivided thenuse one line for each subsection wetted perimeter

Column 7 R is the hydraulic radius Use the same procedure as for Column 5 if the sectionis complex but do not add subsection values

Column 8 n is Manningrsquos coefficient of channel roughness

Column 9 K is the conveyance and is determined with Equation 6-4 This column containsthe total conveyance for the cross section If the cross section is complex addsubsection K values to get the total conveyance (Kt)

Column 10 Kave the average conveyance for the reach is computed with Equation F-1

( )K = 12

K + Kave ds us

Equation F-1

Column 11 This column contains the friction slope at the current section and is computedusing Equation 67ndash8

S QKf =

2

Equation F-2

Column 12 The average friction slope is determined using Equation F-3

S QKf ave =

ave

2

Equation F-3

Column 13 L is the distance between cross-sections

Column 14 The energy loss due to friction (hf) through the reach is calculated usingEquation F-4

h = S Lf aveEquation F-4

Column 15 This column contains part of the expression relating distributed flow velocitiesto an average value (see Column 16) If the section is complex calculate one of thesevalues for each subsection and add all subsection values to get a total If one

12of 39

subsection is used you do not need Column 15 and the kinetic energy coefficient(Column 16) equals 10

Column 16 The kinetic energy coefficient (α) is calculated with Equation 6-10

Column 17 The average velocity (V) for the cross section is calculated with the continuityequation (Equation 6-1)

Column 18 This column contains the average velocity head corrected for flowdistribution

Column 19 This column contains the difference between the downstream and upstreamvelocity heads A positive value indicates velocity is increasing therefore use acontraction coefficient to account for ldquoother lossesrdquo A negative value indicates theexpansion coefficient should be used in calculating ldquoother lossesrdquo

Column 20 Calculate the ldquoother lossesrdquo by multiplying either the expansion coefficient(Ke) or contraction coefficient (Kc) by the absolute value of Column 18 That is forexpansion the change in velocity head will be negative but the head loss must bepositive ∆WS is the change in water surface elevation from the previous cross sectionIt is the algebraic sum of Columns 14 19 and 20

Storm Drain Design

Problem Statement

Given The working schematic Figure F-4 shows the layout of the roadway and crossstreets to be drained At the node indicated as A8 on the schematic an outflow from asmall storm drain system within the indicated shopping mall is accepted into thedepartmentrsquos system The storm drain system will outfall into a channel which isdirectly downstream of a culvert as indicated The culvert accommodates flow from a9065 hectare watershed

13of 39

Figure F-4 Layout of Drainage Areas and Inlets

14of 39

The hydrology and inlet data for this example are given in Hydrology and Inlet Informationtable This table includes the following for each drainage area

diams area

diams time of concentration

diams gutter slope

diams reciprocal of the cross slope

Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

A1 Curb 069010

055085 75 24 00050

A2 SGrate 006 070 20 32B1 Slot 011 085 32 24

00050C1 Curb 078

014050085 145 32 00060

A3 SGrate 010 070 20 32D1 Slot 014 085 41 32 00060E1 Slot 022 050 50 48 00065E2 Curb 042

011055085 135 48 00060

A4 JuncG1 Curb 041

011050085 90 32 00060

A5 SGrate 005 070 20 32F1 Slot 009 085 36 32 00060H1 Curb 008

006055085 60 48 00030

H2 Curb 012022

055085 65 48 00050

15of 39

(continued) Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

I1 Slot 032007

055085 80 48 00030

K1 Grate 066013

040085 150 48 00040

J1 Scurb 043021

060085 88 32

L1 Grate 030007

055085 177 48 00040

L2 Grate 024 085 36 48 00040L3 Grate 017 085 30 48 00040A6 JuncM1 SCurb 033 085 42 32A7 SGrate 004 070 20 32N1 SCurb 041 085 70 32Offsite 018

149070085 116

A8 JuncA9 Sgrate 012 070 34 32A10 Outfall

The Conduit Information table presents conduit design information such as soffitelevations and pipe lengths The General Given Information table contains generalinformation including

diams rainfall intensity factors

diams allowable ponded widths and

diams inlet requirements

16of 39

Conduit InformationIdentificationsUS DS

Length (m) US Soffit Elev (m)

A1 A2 20 256760B1 A2 20 256730A2 A3 100 256670C1 A3 20 256260D1 A3 20 256270A3 A4 20 256200E1 E2 90 256600E2 A4 20 256150A4 A5 75 256090G1 A5 20 255810F1 A5 25 255830A5 A6 75 255730J1 G1 25 255940H1 H2 125 255880I1 H2 60 255810H2 A6 57 255560L1 L2 95 256320K1 L2 55 256070L2 L3 86 255850L3 A6 20 255570A6 A7 56 255490M1 A7 20 255300N1 A7 18 255240A7 A8 60 255220A8 A9 104 254880A9 A10 40 254270

17of 39

General Given InformationDesign Frequency 5 years (20 chance of exceedance)Rainfall intensity factors e = 078 b = 1422 mm d = 82Curb height 015 mMinimum time of concentration 10 minutesMinimum curb inlet length 15 mMinimum slotted drain inlet length 6 mStandard grate inlets Parallel bars wtransverse rods

W = 05 m and L = 1 mGrate inlets on sag in median 05 m x 05 m square inlets bar area =

25 of grate area allowable pondeddepth = 06 m

Gutter depression for curb inlets 75 mmAllowable ponded width 36 m on Lone Star Blvd and 45 m on

Texas AveCurb inlets on sag slope = 00050 mm and 50 of

discharge on each side of inletOutfall tailwater elevation (2 yr) 254360 m

Required Design a storm drain system to accommodate the design discharge

Discussion The following example represents a single iteration of the design process It isone of a series of iterations that would require revision re-analysis and optimizationuntil a technically acceptable and economical design is accomplished

In a production design all design parameters and criteria must be met The illustration ofthe hydraulic grade line is for demonstration only Typically the hydraulic grade line isdeveloped as a last design step after the system has been optimized The next subsectionsoffer initial design process components and a design iteration procedure

Initial Design Process Components

The initial design process consists basically of the following three components

diams hydrology

diams inlet design and

diams conduit design

These components will be addressed individually However it is important to understandthat all three components must function together simultaneously You must evaluate thehydrology aspects with respect to both inlet design and conduit design

18of 39

Design Iteration Procedure

The following steps illustrate the activities in a single design iteration

Design Iteration ProcedureStep Action

Step 1 Prepare a system planStep 2 Base initial runoff computations on Rational Method and tabulate them in

Conduit Information tableStep 3 Locate inlets based on logic and hydraulic demand and configure the conduit

system

Step 1

Prepare a system plan

Prepare a system plan as discussed in Section 2 System Planning Effectively the exampleproblem is identified as delineated in the problem statement Ensure there are no ldquodeadrdquospots where the runoff has no outlet Establish the general location of inlets the laterals andthe trunk lines You must coordinate the logical location of the various system componentswith the component locations necessary to satisfy hydraulic demand In subsequent designiterations you may change any or all parts of the system configuration as necessary

a Establish the design parameters and criteriab Select materials and shapes to be usedc Assign the design frequencyd Identify utility intersections with respect to

bull locationbull typebull owner and probable disposition

e Identify detention facilities

19of 39

Step 2

Base initial runoff computations on the Rational Method and tabulate them in ConduitInformation table The first four columns of this tabulation are self-explanatory The totalCA as shown in the fifth column is computed by multiplying each incremental area by itscorresponding coefficient of runoff and summing these incremental products As anexample the total CA for drainage area A1 is computed as follows

Type Hectares C CAPaved 010 x 085 = 0085Residential 069 x 055 = 0380TOTALS 079 0465

20of 39

Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

A1 Curb 069010

055085

0465 75 100 14793 0191

A2 SGrate 006 070 0042 20 100 14793 0017B1 Slot 011 085 0094 32 100 14793 0038C1 Curb 078

014050085 0509 145 145 12451 0176

A3 SGrate 010 070 0070 20 100 14793 0029D1 Slot 014 085 0119 41 100 14793 0049E1 Slot 022 050 0110 50 100 14793 0045E2 Curb 042

011055085 0325 135 135 12896 0116

A4 Junc 000 000G1 Curb 041

011050085 0299 90 100 14793 0123

A5 SGrate 005 070 0035 20 100 14793 0014F1 Slot 009 085 0077 36 100 14793 0031H1 Curb 008

006055085 0095 60 100 14793 0039

H2 Curb 012022

055085 0253 65 100 14793 0104

I1 Slot 032007

055085 0236 80 100 14793 0097

21of 39

(continued) Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

K1 Grate 066013

040085 0375 150 150 12241 0127

J1 SCurb 043021

060085 0437 88 100 14793 0180

L1 Grate 030007

055085 0225 177 177 11234 0070

L2 Grate 024 085 0204 36 100 14793 0084L3 Grate 017 085 0145 30 100 14793 0059A6 Junc 000 000M1 SCurb 033 085 0281 42 100 14793 0115A7 SGrate 004 070 0028 20 100 14793 0012N1 SCurb 041 085 0349 70 100 14793 0143Offsite 018

149070085 1393 116 116 13852 0536

A8 Junc 000 000A9 SGrate 012 070 0084 34 100 14793 0035A10 Outfall 000 000

a In the Summary of Hydrologic Computations table note that the operating timeof concentration has a minimum value of 10 minutes (according to departmentpractice) However it is necessary to account for the smaller time of concentrationtherefore the actual time of concentration (minimum notwithstanding) is alsotabulated

b The rainfall intensity (I) is based on Equation F-5 where e = 078 b = 1422 and d= 82 For drainage area A1 the time of concentration is only 75 minutesTherefore using 10 minutes as a basis the rainfall intensity is calculated as 1479mmhr

If =b

tc + d( )e

Equation F-5where

If=rainfall intensity for frequency (mmhr)tc=time of concentration (min)e b d= empirical factors which are tabulated for each county in Texas

for frequencies of 2 5 10 25 50 and 100 years in Appendix Bc The peak discharge (Q) is determined by multiplying CA by I and 000278

(Equation F-6)

Q = C I A360

22of 39

Equation F-6whereQ =peak discharge (m3s)C =runoff coefficientI =rainfall intensity associated with a specific frequency (mmhr)A =area of the watershed (ha)

d For watershed A1 Q is 0191 m3sStep 3

Locate the inlets based on logic and hydraulic demand and configure the conduit systema Locate the inlets based on logic and hydraulic demand as outlined in Section 5

Storm Drain Inletsb Finally after locating the inlets (establishing the nodes for the storm drain system)

you can configure the conduit system

Tables F-7 to F-13 show the suggested tabular format for calculations in the design of theinlet system in this example Since the design process is iterative requiring adjustments andre-analysis until the design is optimized the examples shown are only a ldquosnapshotrdquo (or oneiteration) during the design process

Inlets On-Grade Explanation

C = =

=

C A

A

n nn

m

nn

m1

1

Equation F-7where

C=weighted runoff coefficientn=nth subaream=number of subareasCn=runoff coefficient for nth subareaAn=nth subarea size (ha)

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 11: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

11of 39

Column 5 A is the cross-sectional area If the section is complex and has been subdividedinto several parts (eg left overbank channel and right overbank) then use one line ofthe form for each subsection and add to get the total area of cross section (At)

Column 6 This column contains the wetted perimeter If the section is subdivided thenuse one line for each subsection wetted perimeter

Column 7 R is the hydraulic radius Use the same procedure as for Column 5 if the sectionis complex but do not add subsection values

Column 8 n is Manningrsquos coefficient of channel roughness

Column 9 K is the conveyance and is determined with Equation 6-4 This column containsthe total conveyance for the cross section If the cross section is complex addsubsection K values to get the total conveyance (Kt)

Column 10 Kave the average conveyance for the reach is computed with Equation F-1

( )K = 12

K + Kave ds us

Equation F-1

Column 11 This column contains the friction slope at the current section and is computedusing Equation 67ndash8

S QKf =

2

Equation F-2

Column 12 The average friction slope is determined using Equation F-3

S QKf ave =

ave

2

Equation F-3

Column 13 L is the distance between cross-sections

Column 14 The energy loss due to friction (hf) through the reach is calculated usingEquation F-4

h = S Lf aveEquation F-4

Column 15 This column contains part of the expression relating distributed flow velocitiesto an average value (see Column 16) If the section is complex calculate one of thesevalues for each subsection and add all subsection values to get a total If one

12of 39

subsection is used you do not need Column 15 and the kinetic energy coefficient(Column 16) equals 10

Column 16 The kinetic energy coefficient (α) is calculated with Equation 6-10

Column 17 The average velocity (V) for the cross section is calculated with the continuityequation (Equation 6-1)

Column 18 This column contains the average velocity head corrected for flowdistribution

Column 19 This column contains the difference between the downstream and upstreamvelocity heads A positive value indicates velocity is increasing therefore use acontraction coefficient to account for ldquoother lossesrdquo A negative value indicates theexpansion coefficient should be used in calculating ldquoother lossesrdquo

Column 20 Calculate the ldquoother lossesrdquo by multiplying either the expansion coefficient(Ke) or contraction coefficient (Kc) by the absolute value of Column 18 That is forexpansion the change in velocity head will be negative but the head loss must bepositive ∆WS is the change in water surface elevation from the previous cross sectionIt is the algebraic sum of Columns 14 19 and 20

Storm Drain Design

Problem Statement

Given The working schematic Figure F-4 shows the layout of the roadway and crossstreets to be drained At the node indicated as A8 on the schematic an outflow from asmall storm drain system within the indicated shopping mall is accepted into thedepartmentrsquos system The storm drain system will outfall into a channel which isdirectly downstream of a culvert as indicated The culvert accommodates flow from a9065 hectare watershed

13of 39

Figure F-4 Layout of Drainage Areas and Inlets

14of 39

The hydrology and inlet data for this example are given in Hydrology and Inlet Informationtable This table includes the following for each drainage area

diams area

diams time of concentration

diams gutter slope

diams reciprocal of the cross slope

Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

A1 Curb 069010

055085 75 24 00050

A2 SGrate 006 070 20 32B1 Slot 011 085 32 24

00050C1 Curb 078

014050085 145 32 00060

A3 SGrate 010 070 20 32D1 Slot 014 085 41 32 00060E1 Slot 022 050 50 48 00065E2 Curb 042

011055085 135 48 00060

A4 JuncG1 Curb 041

011050085 90 32 00060

A5 SGrate 005 070 20 32F1 Slot 009 085 36 32 00060H1 Curb 008

006055085 60 48 00030

H2 Curb 012022

055085 65 48 00050

15of 39

(continued) Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

I1 Slot 032007

055085 80 48 00030

K1 Grate 066013

040085 150 48 00040

J1 Scurb 043021

060085 88 32

L1 Grate 030007

055085 177 48 00040

L2 Grate 024 085 36 48 00040L3 Grate 017 085 30 48 00040A6 JuncM1 SCurb 033 085 42 32A7 SGrate 004 070 20 32N1 SCurb 041 085 70 32Offsite 018

149070085 116

A8 JuncA9 Sgrate 012 070 34 32A10 Outfall

The Conduit Information table presents conduit design information such as soffitelevations and pipe lengths The General Given Information table contains generalinformation including

diams rainfall intensity factors

diams allowable ponded widths and

diams inlet requirements

16of 39

Conduit InformationIdentificationsUS DS

Length (m) US Soffit Elev (m)

A1 A2 20 256760B1 A2 20 256730A2 A3 100 256670C1 A3 20 256260D1 A3 20 256270A3 A4 20 256200E1 E2 90 256600E2 A4 20 256150A4 A5 75 256090G1 A5 20 255810F1 A5 25 255830A5 A6 75 255730J1 G1 25 255940H1 H2 125 255880I1 H2 60 255810H2 A6 57 255560L1 L2 95 256320K1 L2 55 256070L2 L3 86 255850L3 A6 20 255570A6 A7 56 255490M1 A7 20 255300N1 A7 18 255240A7 A8 60 255220A8 A9 104 254880A9 A10 40 254270

17of 39

General Given InformationDesign Frequency 5 years (20 chance of exceedance)Rainfall intensity factors e = 078 b = 1422 mm d = 82Curb height 015 mMinimum time of concentration 10 minutesMinimum curb inlet length 15 mMinimum slotted drain inlet length 6 mStandard grate inlets Parallel bars wtransverse rods

W = 05 m and L = 1 mGrate inlets on sag in median 05 m x 05 m square inlets bar area =

25 of grate area allowable pondeddepth = 06 m

Gutter depression for curb inlets 75 mmAllowable ponded width 36 m on Lone Star Blvd and 45 m on

Texas AveCurb inlets on sag slope = 00050 mm and 50 of

discharge on each side of inletOutfall tailwater elevation (2 yr) 254360 m

Required Design a storm drain system to accommodate the design discharge

Discussion The following example represents a single iteration of the design process It isone of a series of iterations that would require revision re-analysis and optimizationuntil a technically acceptable and economical design is accomplished

In a production design all design parameters and criteria must be met The illustration ofthe hydraulic grade line is for demonstration only Typically the hydraulic grade line isdeveloped as a last design step after the system has been optimized The next subsectionsoffer initial design process components and a design iteration procedure

Initial Design Process Components

The initial design process consists basically of the following three components

diams hydrology

diams inlet design and

diams conduit design

These components will be addressed individually However it is important to understandthat all three components must function together simultaneously You must evaluate thehydrology aspects with respect to both inlet design and conduit design

18of 39

Design Iteration Procedure

The following steps illustrate the activities in a single design iteration

Design Iteration ProcedureStep Action

Step 1 Prepare a system planStep 2 Base initial runoff computations on Rational Method and tabulate them in

Conduit Information tableStep 3 Locate inlets based on logic and hydraulic demand and configure the conduit

system

Step 1

Prepare a system plan

Prepare a system plan as discussed in Section 2 System Planning Effectively the exampleproblem is identified as delineated in the problem statement Ensure there are no ldquodeadrdquospots where the runoff has no outlet Establish the general location of inlets the laterals andthe trunk lines You must coordinate the logical location of the various system componentswith the component locations necessary to satisfy hydraulic demand In subsequent designiterations you may change any or all parts of the system configuration as necessary

a Establish the design parameters and criteriab Select materials and shapes to be usedc Assign the design frequencyd Identify utility intersections with respect to

bull locationbull typebull owner and probable disposition

e Identify detention facilities

19of 39

Step 2

Base initial runoff computations on the Rational Method and tabulate them in ConduitInformation table The first four columns of this tabulation are self-explanatory The totalCA as shown in the fifth column is computed by multiplying each incremental area by itscorresponding coefficient of runoff and summing these incremental products As anexample the total CA for drainage area A1 is computed as follows

Type Hectares C CAPaved 010 x 085 = 0085Residential 069 x 055 = 0380TOTALS 079 0465

20of 39

Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

A1 Curb 069010

055085

0465 75 100 14793 0191

A2 SGrate 006 070 0042 20 100 14793 0017B1 Slot 011 085 0094 32 100 14793 0038C1 Curb 078

014050085 0509 145 145 12451 0176

A3 SGrate 010 070 0070 20 100 14793 0029D1 Slot 014 085 0119 41 100 14793 0049E1 Slot 022 050 0110 50 100 14793 0045E2 Curb 042

011055085 0325 135 135 12896 0116

A4 Junc 000 000G1 Curb 041

011050085 0299 90 100 14793 0123

A5 SGrate 005 070 0035 20 100 14793 0014F1 Slot 009 085 0077 36 100 14793 0031H1 Curb 008

006055085 0095 60 100 14793 0039

H2 Curb 012022

055085 0253 65 100 14793 0104

I1 Slot 032007

055085 0236 80 100 14793 0097

21of 39

(continued) Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

K1 Grate 066013

040085 0375 150 150 12241 0127

J1 SCurb 043021

060085 0437 88 100 14793 0180

L1 Grate 030007

055085 0225 177 177 11234 0070

L2 Grate 024 085 0204 36 100 14793 0084L3 Grate 017 085 0145 30 100 14793 0059A6 Junc 000 000M1 SCurb 033 085 0281 42 100 14793 0115A7 SGrate 004 070 0028 20 100 14793 0012N1 SCurb 041 085 0349 70 100 14793 0143Offsite 018

149070085 1393 116 116 13852 0536

A8 Junc 000 000A9 SGrate 012 070 0084 34 100 14793 0035A10 Outfall 000 000

a In the Summary of Hydrologic Computations table note that the operating timeof concentration has a minimum value of 10 minutes (according to departmentpractice) However it is necessary to account for the smaller time of concentrationtherefore the actual time of concentration (minimum notwithstanding) is alsotabulated

b The rainfall intensity (I) is based on Equation F-5 where e = 078 b = 1422 and d= 82 For drainage area A1 the time of concentration is only 75 minutesTherefore using 10 minutes as a basis the rainfall intensity is calculated as 1479mmhr

If =b

tc + d( )e

Equation F-5where

If=rainfall intensity for frequency (mmhr)tc=time of concentration (min)e b d= empirical factors which are tabulated for each county in Texas

for frequencies of 2 5 10 25 50 and 100 years in Appendix Bc The peak discharge (Q) is determined by multiplying CA by I and 000278

(Equation F-6)

Q = C I A360

22of 39

Equation F-6whereQ =peak discharge (m3s)C =runoff coefficientI =rainfall intensity associated with a specific frequency (mmhr)A =area of the watershed (ha)

d For watershed A1 Q is 0191 m3sStep 3

Locate the inlets based on logic and hydraulic demand and configure the conduit systema Locate the inlets based on logic and hydraulic demand as outlined in Section 5

Storm Drain Inletsb Finally after locating the inlets (establishing the nodes for the storm drain system)

you can configure the conduit system

Tables F-7 to F-13 show the suggested tabular format for calculations in the design of theinlet system in this example Since the design process is iterative requiring adjustments andre-analysis until the design is optimized the examples shown are only a ldquosnapshotrdquo (or oneiteration) during the design process

Inlets On-Grade Explanation

C = =

=

C A

A

n nn

m

nn

m1

1

Equation F-7where

C=weighted runoff coefficientn=nth subaream=number of subareasCn=runoff coefficient for nth subareaAn=nth subarea size (ha)

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 12: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

12of 39

subsection is used you do not need Column 15 and the kinetic energy coefficient(Column 16) equals 10

Column 16 The kinetic energy coefficient (α) is calculated with Equation 6-10

Column 17 The average velocity (V) for the cross section is calculated with the continuityequation (Equation 6-1)

Column 18 This column contains the average velocity head corrected for flowdistribution

Column 19 This column contains the difference between the downstream and upstreamvelocity heads A positive value indicates velocity is increasing therefore use acontraction coefficient to account for ldquoother lossesrdquo A negative value indicates theexpansion coefficient should be used in calculating ldquoother lossesrdquo

Column 20 Calculate the ldquoother lossesrdquo by multiplying either the expansion coefficient(Ke) or contraction coefficient (Kc) by the absolute value of Column 18 That is forexpansion the change in velocity head will be negative but the head loss must bepositive ∆WS is the change in water surface elevation from the previous cross sectionIt is the algebraic sum of Columns 14 19 and 20

Storm Drain Design

Problem Statement

Given The working schematic Figure F-4 shows the layout of the roadway and crossstreets to be drained At the node indicated as A8 on the schematic an outflow from asmall storm drain system within the indicated shopping mall is accepted into thedepartmentrsquos system The storm drain system will outfall into a channel which isdirectly downstream of a culvert as indicated The culvert accommodates flow from a9065 hectare watershed

13of 39

Figure F-4 Layout of Drainage Areas and Inlets

14of 39

The hydrology and inlet data for this example are given in Hydrology and Inlet Informationtable This table includes the following for each drainage area

diams area

diams time of concentration

diams gutter slope

diams reciprocal of the cross slope

Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

A1 Curb 069010

055085 75 24 00050

A2 SGrate 006 070 20 32B1 Slot 011 085 32 24

00050C1 Curb 078

014050085 145 32 00060

A3 SGrate 010 070 20 32D1 Slot 014 085 41 32 00060E1 Slot 022 050 50 48 00065E2 Curb 042

011055085 135 48 00060

A4 JuncG1 Curb 041

011050085 90 32 00060

A5 SGrate 005 070 20 32F1 Slot 009 085 36 32 00060H1 Curb 008

006055085 60 48 00030

H2 Curb 012022

055085 65 48 00050

15of 39

(continued) Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

I1 Slot 032007

055085 80 48 00030

K1 Grate 066013

040085 150 48 00040

J1 Scurb 043021

060085 88 32

L1 Grate 030007

055085 177 48 00040

L2 Grate 024 085 36 48 00040L3 Grate 017 085 30 48 00040A6 JuncM1 SCurb 033 085 42 32A7 SGrate 004 070 20 32N1 SCurb 041 085 70 32Offsite 018

149070085 116

A8 JuncA9 Sgrate 012 070 34 32A10 Outfall

The Conduit Information table presents conduit design information such as soffitelevations and pipe lengths The General Given Information table contains generalinformation including

diams rainfall intensity factors

diams allowable ponded widths and

diams inlet requirements

16of 39

Conduit InformationIdentificationsUS DS

Length (m) US Soffit Elev (m)

A1 A2 20 256760B1 A2 20 256730A2 A3 100 256670C1 A3 20 256260D1 A3 20 256270A3 A4 20 256200E1 E2 90 256600E2 A4 20 256150A4 A5 75 256090G1 A5 20 255810F1 A5 25 255830A5 A6 75 255730J1 G1 25 255940H1 H2 125 255880I1 H2 60 255810H2 A6 57 255560L1 L2 95 256320K1 L2 55 256070L2 L3 86 255850L3 A6 20 255570A6 A7 56 255490M1 A7 20 255300N1 A7 18 255240A7 A8 60 255220A8 A9 104 254880A9 A10 40 254270

17of 39

General Given InformationDesign Frequency 5 years (20 chance of exceedance)Rainfall intensity factors e = 078 b = 1422 mm d = 82Curb height 015 mMinimum time of concentration 10 minutesMinimum curb inlet length 15 mMinimum slotted drain inlet length 6 mStandard grate inlets Parallel bars wtransverse rods

W = 05 m and L = 1 mGrate inlets on sag in median 05 m x 05 m square inlets bar area =

25 of grate area allowable pondeddepth = 06 m

Gutter depression for curb inlets 75 mmAllowable ponded width 36 m on Lone Star Blvd and 45 m on

Texas AveCurb inlets on sag slope = 00050 mm and 50 of

discharge on each side of inletOutfall tailwater elevation (2 yr) 254360 m

Required Design a storm drain system to accommodate the design discharge

Discussion The following example represents a single iteration of the design process It isone of a series of iterations that would require revision re-analysis and optimizationuntil a technically acceptable and economical design is accomplished

In a production design all design parameters and criteria must be met The illustration ofthe hydraulic grade line is for demonstration only Typically the hydraulic grade line isdeveloped as a last design step after the system has been optimized The next subsectionsoffer initial design process components and a design iteration procedure

Initial Design Process Components

The initial design process consists basically of the following three components

diams hydrology

diams inlet design and

diams conduit design

These components will be addressed individually However it is important to understandthat all three components must function together simultaneously You must evaluate thehydrology aspects with respect to both inlet design and conduit design

18of 39

Design Iteration Procedure

The following steps illustrate the activities in a single design iteration

Design Iteration ProcedureStep Action

Step 1 Prepare a system planStep 2 Base initial runoff computations on Rational Method and tabulate them in

Conduit Information tableStep 3 Locate inlets based on logic and hydraulic demand and configure the conduit

system

Step 1

Prepare a system plan

Prepare a system plan as discussed in Section 2 System Planning Effectively the exampleproblem is identified as delineated in the problem statement Ensure there are no ldquodeadrdquospots where the runoff has no outlet Establish the general location of inlets the laterals andthe trunk lines You must coordinate the logical location of the various system componentswith the component locations necessary to satisfy hydraulic demand In subsequent designiterations you may change any or all parts of the system configuration as necessary

a Establish the design parameters and criteriab Select materials and shapes to be usedc Assign the design frequencyd Identify utility intersections with respect to

bull locationbull typebull owner and probable disposition

e Identify detention facilities

19of 39

Step 2

Base initial runoff computations on the Rational Method and tabulate them in ConduitInformation table The first four columns of this tabulation are self-explanatory The totalCA as shown in the fifth column is computed by multiplying each incremental area by itscorresponding coefficient of runoff and summing these incremental products As anexample the total CA for drainage area A1 is computed as follows

Type Hectares C CAPaved 010 x 085 = 0085Residential 069 x 055 = 0380TOTALS 079 0465

20of 39

Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

A1 Curb 069010

055085

0465 75 100 14793 0191

A2 SGrate 006 070 0042 20 100 14793 0017B1 Slot 011 085 0094 32 100 14793 0038C1 Curb 078

014050085 0509 145 145 12451 0176

A3 SGrate 010 070 0070 20 100 14793 0029D1 Slot 014 085 0119 41 100 14793 0049E1 Slot 022 050 0110 50 100 14793 0045E2 Curb 042

011055085 0325 135 135 12896 0116

A4 Junc 000 000G1 Curb 041

011050085 0299 90 100 14793 0123

A5 SGrate 005 070 0035 20 100 14793 0014F1 Slot 009 085 0077 36 100 14793 0031H1 Curb 008

006055085 0095 60 100 14793 0039

H2 Curb 012022

055085 0253 65 100 14793 0104

I1 Slot 032007

055085 0236 80 100 14793 0097

21of 39

(continued) Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

K1 Grate 066013

040085 0375 150 150 12241 0127

J1 SCurb 043021

060085 0437 88 100 14793 0180

L1 Grate 030007

055085 0225 177 177 11234 0070

L2 Grate 024 085 0204 36 100 14793 0084L3 Grate 017 085 0145 30 100 14793 0059A6 Junc 000 000M1 SCurb 033 085 0281 42 100 14793 0115A7 SGrate 004 070 0028 20 100 14793 0012N1 SCurb 041 085 0349 70 100 14793 0143Offsite 018

149070085 1393 116 116 13852 0536

A8 Junc 000 000A9 SGrate 012 070 0084 34 100 14793 0035A10 Outfall 000 000

a In the Summary of Hydrologic Computations table note that the operating timeof concentration has a minimum value of 10 minutes (according to departmentpractice) However it is necessary to account for the smaller time of concentrationtherefore the actual time of concentration (minimum notwithstanding) is alsotabulated

b The rainfall intensity (I) is based on Equation F-5 where e = 078 b = 1422 and d= 82 For drainage area A1 the time of concentration is only 75 minutesTherefore using 10 minutes as a basis the rainfall intensity is calculated as 1479mmhr

If =b

tc + d( )e

Equation F-5where

If=rainfall intensity for frequency (mmhr)tc=time of concentration (min)e b d= empirical factors which are tabulated for each county in Texas

for frequencies of 2 5 10 25 50 and 100 years in Appendix Bc The peak discharge (Q) is determined by multiplying CA by I and 000278

(Equation F-6)

Q = C I A360

22of 39

Equation F-6whereQ =peak discharge (m3s)C =runoff coefficientI =rainfall intensity associated with a specific frequency (mmhr)A =area of the watershed (ha)

d For watershed A1 Q is 0191 m3sStep 3

Locate the inlets based on logic and hydraulic demand and configure the conduit systema Locate the inlets based on logic and hydraulic demand as outlined in Section 5

Storm Drain Inletsb Finally after locating the inlets (establishing the nodes for the storm drain system)

you can configure the conduit system

Tables F-7 to F-13 show the suggested tabular format for calculations in the design of theinlet system in this example Since the design process is iterative requiring adjustments andre-analysis until the design is optimized the examples shown are only a ldquosnapshotrdquo (or oneiteration) during the design process

Inlets On-Grade Explanation

C = =

=

C A

A

n nn

m

nn

m1

1

Equation F-7where

C=weighted runoff coefficientn=nth subaream=number of subareasCn=runoff coefficient for nth subareaAn=nth subarea size (ha)

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 13: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

13of 39

Figure F-4 Layout of Drainage Areas and Inlets

14of 39

The hydrology and inlet data for this example are given in Hydrology and Inlet Informationtable This table includes the following for each drainage area

diams area

diams time of concentration

diams gutter slope

diams reciprocal of the cross slope

Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

A1 Curb 069010

055085 75 24 00050

A2 SGrate 006 070 20 32B1 Slot 011 085 32 24

00050C1 Curb 078

014050085 145 32 00060

A3 SGrate 010 070 20 32D1 Slot 014 085 41 32 00060E1 Slot 022 050 50 48 00065E2 Curb 042

011055085 135 48 00060

A4 JuncG1 Curb 041

011050085 90 32 00060

A5 SGrate 005 070 20 32F1 Slot 009 085 36 32 00060H1 Curb 008

006055085 60 48 00030

H2 Curb 012022

055085 65 48 00050

15of 39

(continued) Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

I1 Slot 032007

055085 80 48 00030

K1 Grate 066013

040085 150 48 00040

J1 Scurb 043021

060085 88 32

L1 Grate 030007

055085 177 48 00040

L2 Grate 024 085 36 48 00040L3 Grate 017 085 30 48 00040A6 JuncM1 SCurb 033 085 42 32A7 SGrate 004 070 20 32N1 SCurb 041 085 70 32Offsite 018

149070085 116

A8 JuncA9 Sgrate 012 070 34 32A10 Outfall

The Conduit Information table presents conduit design information such as soffitelevations and pipe lengths The General Given Information table contains generalinformation including

diams rainfall intensity factors

diams allowable ponded widths and

diams inlet requirements

16of 39

Conduit InformationIdentificationsUS DS

Length (m) US Soffit Elev (m)

A1 A2 20 256760B1 A2 20 256730A2 A3 100 256670C1 A3 20 256260D1 A3 20 256270A3 A4 20 256200E1 E2 90 256600E2 A4 20 256150A4 A5 75 256090G1 A5 20 255810F1 A5 25 255830A5 A6 75 255730J1 G1 25 255940H1 H2 125 255880I1 H2 60 255810H2 A6 57 255560L1 L2 95 256320K1 L2 55 256070L2 L3 86 255850L3 A6 20 255570A6 A7 56 255490M1 A7 20 255300N1 A7 18 255240A7 A8 60 255220A8 A9 104 254880A9 A10 40 254270

17of 39

General Given InformationDesign Frequency 5 years (20 chance of exceedance)Rainfall intensity factors e = 078 b = 1422 mm d = 82Curb height 015 mMinimum time of concentration 10 minutesMinimum curb inlet length 15 mMinimum slotted drain inlet length 6 mStandard grate inlets Parallel bars wtransverse rods

W = 05 m and L = 1 mGrate inlets on sag in median 05 m x 05 m square inlets bar area =

25 of grate area allowable pondeddepth = 06 m

Gutter depression for curb inlets 75 mmAllowable ponded width 36 m on Lone Star Blvd and 45 m on

Texas AveCurb inlets on sag slope = 00050 mm and 50 of

discharge on each side of inletOutfall tailwater elevation (2 yr) 254360 m

Required Design a storm drain system to accommodate the design discharge

Discussion The following example represents a single iteration of the design process It isone of a series of iterations that would require revision re-analysis and optimizationuntil a technically acceptable and economical design is accomplished

In a production design all design parameters and criteria must be met The illustration ofthe hydraulic grade line is for demonstration only Typically the hydraulic grade line isdeveloped as a last design step after the system has been optimized The next subsectionsoffer initial design process components and a design iteration procedure

Initial Design Process Components

The initial design process consists basically of the following three components

diams hydrology

diams inlet design and

diams conduit design

These components will be addressed individually However it is important to understandthat all three components must function together simultaneously You must evaluate thehydrology aspects with respect to both inlet design and conduit design

18of 39

Design Iteration Procedure

The following steps illustrate the activities in a single design iteration

Design Iteration ProcedureStep Action

Step 1 Prepare a system planStep 2 Base initial runoff computations on Rational Method and tabulate them in

Conduit Information tableStep 3 Locate inlets based on logic and hydraulic demand and configure the conduit

system

Step 1

Prepare a system plan

Prepare a system plan as discussed in Section 2 System Planning Effectively the exampleproblem is identified as delineated in the problem statement Ensure there are no ldquodeadrdquospots where the runoff has no outlet Establish the general location of inlets the laterals andthe trunk lines You must coordinate the logical location of the various system componentswith the component locations necessary to satisfy hydraulic demand In subsequent designiterations you may change any or all parts of the system configuration as necessary

a Establish the design parameters and criteriab Select materials and shapes to be usedc Assign the design frequencyd Identify utility intersections with respect to

bull locationbull typebull owner and probable disposition

e Identify detention facilities

19of 39

Step 2

Base initial runoff computations on the Rational Method and tabulate them in ConduitInformation table The first four columns of this tabulation are self-explanatory The totalCA as shown in the fifth column is computed by multiplying each incremental area by itscorresponding coefficient of runoff and summing these incremental products As anexample the total CA for drainage area A1 is computed as follows

Type Hectares C CAPaved 010 x 085 = 0085Residential 069 x 055 = 0380TOTALS 079 0465

20of 39

Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

A1 Curb 069010

055085

0465 75 100 14793 0191

A2 SGrate 006 070 0042 20 100 14793 0017B1 Slot 011 085 0094 32 100 14793 0038C1 Curb 078

014050085 0509 145 145 12451 0176

A3 SGrate 010 070 0070 20 100 14793 0029D1 Slot 014 085 0119 41 100 14793 0049E1 Slot 022 050 0110 50 100 14793 0045E2 Curb 042

011055085 0325 135 135 12896 0116

A4 Junc 000 000G1 Curb 041

011050085 0299 90 100 14793 0123

A5 SGrate 005 070 0035 20 100 14793 0014F1 Slot 009 085 0077 36 100 14793 0031H1 Curb 008

006055085 0095 60 100 14793 0039

H2 Curb 012022

055085 0253 65 100 14793 0104

I1 Slot 032007

055085 0236 80 100 14793 0097

21of 39

(continued) Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

K1 Grate 066013

040085 0375 150 150 12241 0127

J1 SCurb 043021

060085 0437 88 100 14793 0180

L1 Grate 030007

055085 0225 177 177 11234 0070

L2 Grate 024 085 0204 36 100 14793 0084L3 Grate 017 085 0145 30 100 14793 0059A6 Junc 000 000M1 SCurb 033 085 0281 42 100 14793 0115A7 SGrate 004 070 0028 20 100 14793 0012N1 SCurb 041 085 0349 70 100 14793 0143Offsite 018

149070085 1393 116 116 13852 0536

A8 Junc 000 000A9 SGrate 012 070 0084 34 100 14793 0035A10 Outfall 000 000

a In the Summary of Hydrologic Computations table note that the operating timeof concentration has a minimum value of 10 minutes (according to departmentpractice) However it is necessary to account for the smaller time of concentrationtherefore the actual time of concentration (minimum notwithstanding) is alsotabulated

b The rainfall intensity (I) is based on Equation F-5 where e = 078 b = 1422 and d= 82 For drainage area A1 the time of concentration is only 75 minutesTherefore using 10 minutes as a basis the rainfall intensity is calculated as 1479mmhr

If =b

tc + d( )e

Equation F-5where

If=rainfall intensity for frequency (mmhr)tc=time of concentration (min)e b d= empirical factors which are tabulated for each county in Texas

for frequencies of 2 5 10 25 50 and 100 years in Appendix Bc The peak discharge (Q) is determined by multiplying CA by I and 000278

(Equation F-6)

Q = C I A360

22of 39

Equation F-6whereQ =peak discharge (m3s)C =runoff coefficientI =rainfall intensity associated with a specific frequency (mmhr)A =area of the watershed (ha)

d For watershed A1 Q is 0191 m3sStep 3

Locate the inlets based on logic and hydraulic demand and configure the conduit systema Locate the inlets based on logic and hydraulic demand as outlined in Section 5

Storm Drain Inletsb Finally after locating the inlets (establishing the nodes for the storm drain system)

you can configure the conduit system

Tables F-7 to F-13 show the suggested tabular format for calculations in the design of theinlet system in this example Since the design process is iterative requiring adjustments andre-analysis until the design is optimized the examples shown are only a ldquosnapshotrdquo (or oneiteration) during the design process

Inlets On-Grade Explanation

C = =

=

C A

A

n nn

m

nn

m1

1

Equation F-7where

C=weighted runoff coefficientn=nth subaream=number of subareasCn=runoff coefficient for nth subareaAn=nth subarea size (ha)

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 14: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

14of 39

The hydrology and inlet data for this example are given in Hydrology and Inlet Informationtable This table includes the following for each drainage area

diams area

diams time of concentration

diams gutter slope

diams reciprocal of the cross slope

Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

A1 Curb 069010

055085 75 24 00050

A2 SGrate 006 070 20 32B1 Slot 011 085 32 24

00050C1 Curb 078

014050085 145 32 00060

A3 SGrate 010 070 20 32D1 Slot 014 085 41 32 00060E1 Slot 022 050 50 48 00065E2 Curb 042

011055085 135 48 00060

A4 JuncG1 Curb 041

011050085 90 32 00060

A5 SGrate 005 070 20 32F1 Slot 009 085 36 32 00060H1 Curb 008

006055085 60 48 00030

H2 Curb 012022

055085 65 48 00050

15of 39

(continued) Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

I1 Slot 032007

055085 80 48 00030

K1 Grate 066013

040085 150 48 00040

J1 Scurb 043021

060085 88 32

L1 Grate 030007

055085 177 48 00040

L2 Grate 024 085 36 48 00040L3 Grate 017 085 30 48 00040A6 JuncM1 SCurb 033 085 42 32A7 SGrate 004 070 20 32N1 SCurb 041 085 70 32Offsite 018

149070085 116

A8 JuncA9 Sgrate 012 070 34 32A10 Outfall

The Conduit Information table presents conduit design information such as soffitelevations and pipe lengths The General Given Information table contains generalinformation including

diams rainfall intensity factors

diams allowable ponded widths and

diams inlet requirements

16of 39

Conduit InformationIdentificationsUS DS

Length (m) US Soffit Elev (m)

A1 A2 20 256760B1 A2 20 256730A2 A3 100 256670C1 A3 20 256260D1 A3 20 256270A3 A4 20 256200E1 E2 90 256600E2 A4 20 256150A4 A5 75 256090G1 A5 20 255810F1 A5 25 255830A5 A6 75 255730J1 G1 25 255940H1 H2 125 255880I1 H2 60 255810H2 A6 57 255560L1 L2 95 256320K1 L2 55 256070L2 L3 86 255850L3 A6 20 255570A6 A7 56 255490M1 A7 20 255300N1 A7 18 255240A7 A8 60 255220A8 A9 104 254880A9 A10 40 254270

17of 39

General Given InformationDesign Frequency 5 years (20 chance of exceedance)Rainfall intensity factors e = 078 b = 1422 mm d = 82Curb height 015 mMinimum time of concentration 10 minutesMinimum curb inlet length 15 mMinimum slotted drain inlet length 6 mStandard grate inlets Parallel bars wtransverse rods

W = 05 m and L = 1 mGrate inlets on sag in median 05 m x 05 m square inlets bar area =

25 of grate area allowable pondeddepth = 06 m

Gutter depression for curb inlets 75 mmAllowable ponded width 36 m on Lone Star Blvd and 45 m on

Texas AveCurb inlets on sag slope = 00050 mm and 50 of

discharge on each side of inletOutfall tailwater elevation (2 yr) 254360 m

Required Design a storm drain system to accommodate the design discharge

Discussion The following example represents a single iteration of the design process It isone of a series of iterations that would require revision re-analysis and optimizationuntil a technically acceptable and economical design is accomplished

In a production design all design parameters and criteria must be met The illustration ofthe hydraulic grade line is for demonstration only Typically the hydraulic grade line isdeveloped as a last design step after the system has been optimized The next subsectionsoffer initial design process components and a design iteration procedure

Initial Design Process Components

The initial design process consists basically of the following three components

diams hydrology

diams inlet design and

diams conduit design

These components will be addressed individually However it is important to understandthat all three components must function together simultaneously You must evaluate thehydrology aspects with respect to both inlet design and conduit design

18of 39

Design Iteration Procedure

The following steps illustrate the activities in a single design iteration

Design Iteration ProcedureStep Action

Step 1 Prepare a system planStep 2 Base initial runoff computations on Rational Method and tabulate them in

Conduit Information tableStep 3 Locate inlets based on logic and hydraulic demand and configure the conduit

system

Step 1

Prepare a system plan

Prepare a system plan as discussed in Section 2 System Planning Effectively the exampleproblem is identified as delineated in the problem statement Ensure there are no ldquodeadrdquospots where the runoff has no outlet Establish the general location of inlets the laterals andthe trunk lines You must coordinate the logical location of the various system componentswith the component locations necessary to satisfy hydraulic demand In subsequent designiterations you may change any or all parts of the system configuration as necessary

a Establish the design parameters and criteriab Select materials and shapes to be usedc Assign the design frequencyd Identify utility intersections with respect to

bull locationbull typebull owner and probable disposition

e Identify detention facilities

19of 39

Step 2

Base initial runoff computations on the Rational Method and tabulate them in ConduitInformation table The first four columns of this tabulation are self-explanatory The totalCA as shown in the fifth column is computed by multiplying each incremental area by itscorresponding coefficient of runoff and summing these incremental products As anexample the total CA for drainage area A1 is computed as follows

Type Hectares C CAPaved 010 x 085 = 0085Residential 069 x 055 = 0380TOTALS 079 0465

20of 39

Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

A1 Curb 069010

055085

0465 75 100 14793 0191

A2 SGrate 006 070 0042 20 100 14793 0017B1 Slot 011 085 0094 32 100 14793 0038C1 Curb 078

014050085 0509 145 145 12451 0176

A3 SGrate 010 070 0070 20 100 14793 0029D1 Slot 014 085 0119 41 100 14793 0049E1 Slot 022 050 0110 50 100 14793 0045E2 Curb 042

011055085 0325 135 135 12896 0116

A4 Junc 000 000G1 Curb 041

011050085 0299 90 100 14793 0123

A5 SGrate 005 070 0035 20 100 14793 0014F1 Slot 009 085 0077 36 100 14793 0031H1 Curb 008

006055085 0095 60 100 14793 0039

H2 Curb 012022

055085 0253 65 100 14793 0104

I1 Slot 032007

055085 0236 80 100 14793 0097

21of 39

(continued) Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

K1 Grate 066013

040085 0375 150 150 12241 0127

J1 SCurb 043021

060085 0437 88 100 14793 0180

L1 Grate 030007

055085 0225 177 177 11234 0070

L2 Grate 024 085 0204 36 100 14793 0084L3 Grate 017 085 0145 30 100 14793 0059A6 Junc 000 000M1 SCurb 033 085 0281 42 100 14793 0115A7 SGrate 004 070 0028 20 100 14793 0012N1 SCurb 041 085 0349 70 100 14793 0143Offsite 018

149070085 1393 116 116 13852 0536

A8 Junc 000 000A9 SGrate 012 070 0084 34 100 14793 0035A10 Outfall 000 000

a In the Summary of Hydrologic Computations table note that the operating timeof concentration has a minimum value of 10 minutes (according to departmentpractice) However it is necessary to account for the smaller time of concentrationtherefore the actual time of concentration (minimum notwithstanding) is alsotabulated

b The rainfall intensity (I) is based on Equation F-5 where e = 078 b = 1422 and d= 82 For drainage area A1 the time of concentration is only 75 minutesTherefore using 10 minutes as a basis the rainfall intensity is calculated as 1479mmhr

If =b

tc + d( )e

Equation F-5where

If=rainfall intensity for frequency (mmhr)tc=time of concentration (min)e b d= empirical factors which are tabulated for each county in Texas

for frequencies of 2 5 10 25 50 and 100 years in Appendix Bc The peak discharge (Q) is determined by multiplying CA by I and 000278

(Equation F-6)

Q = C I A360

22of 39

Equation F-6whereQ =peak discharge (m3s)C =runoff coefficientI =rainfall intensity associated with a specific frequency (mmhr)A =area of the watershed (ha)

d For watershed A1 Q is 0191 m3sStep 3

Locate the inlets based on logic and hydraulic demand and configure the conduit systema Locate the inlets based on logic and hydraulic demand as outlined in Section 5

Storm Drain Inletsb Finally after locating the inlets (establishing the nodes for the storm drain system)

you can configure the conduit system

Tables F-7 to F-13 show the suggested tabular format for calculations in the design of theinlet system in this example Since the design process is iterative requiring adjustments andre-analysis until the design is optimized the examples shown are only a ldquosnapshotrdquo (or oneiteration) during the design process

Inlets On-Grade Explanation

C = =

=

C A

A

n nn

m

nn

m1

1

Equation F-7where

C=weighted runoff coefficientn=nth subaream=number of subareasCn=runoff coefficient for nth subareaAn=nth subarea size (ha)

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 15: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

15of 39

(continued) Hydrology and Inlet InformationIdentification Type Area (ha) C Actual Time

(min)1Sx (mm) Slope (mm)

I1 Slot 032007

055085 80 48 00030

K1 Grate 066013

040085 150 48 00040

J1 Scurb 043021

060085 88 32

L1 Grate 030007

055085 177 48 00040

L2 Grate 024 085 36 48 00040L3 Grate 017 085 30 48 00040A6 JuncM1 SCurb 033 085 42 32A7 SGrate 004 070 20 32N1 SCurb 041 085 70 32Offsite 018

149070085 116

A8 JuncA9 Sgrate 012 070 34 32A10 Outfall

The Conduit Information table presents conduit design information such as soffitelevations and pipe lengths The General Given Information table contains generalinformation including

diams rainfall intensity factors

diams allowable ponded widths and

diams inlet requirements

16of 39

Conduit InformationIdentificationsUS DS

Length (m) US Soffit Elev (m)

A1 A2 20 256760B1 A2 20 256730A2 A3 100 256670C1 A3 20 256260D1 A3 20 256270A3 A4 20 256200E1 E2 90 256600E2 A4 20 256150A4 A5 75 256090G1 A5 20 255810F1 A5 25 255830A5 A6 75 255730J1 G1 25 255940H1 H2 125 255880I1 H2 60 255810H2 A6 57 255560L1 L2 95 256320K1 L2 55 256070L2 L3 86 255850L3 A6 20 255570A6 A7 56 255490M1 A7 20 255300N1 A7 18 255240A7 A8 60 255220A8 A9 104 254880A9 A10 40 254270

17of 39

General Given InformationDesign Frequency 5 years (20 chance of exceedance)Rainfall intensity factors e = 078 b = 1422 mm d = 82Curb height 015 mMinimum time of concentration 10 minutesMinimum curb inlet length 15 mMinimum slotted drain inlet length 6 mStandard grate inlets Parallel bars wtransverse rods

W = 05 m and L = 1 mGrate inlets on sag in median 05 m x 05 m square inlets bar area =

25 of grate area allowable pondeddepth = 06 m

Gutter depression for curb inlets 75 mmAllowable ponded width 36 m on Lone Star Blvd and 45 m on

Texas AveCurb inlets on sag slope = 00050 mm and 50 of

discharge on each side of inletOutfall tailwater elevation (2 yr) 254360 m

Required Design a storm drain system to accommodate the design discharge

Discussion The following example represents a single iteration of the design process It isone of a series of iterations that would require revision re-analysis and optimizationuntil a technically acceptable and economical design is accomplished

In a production design all design parameters and criteria must be met The illustration ofthe hydraulic grade line is for demonstration only Typically the hydraulic grade line isdeveloped as a last design step after the system has been optimized The next subsectionsoffer initial design process components and a design iteration procedure

Initial Design Process Components

The initial design process consists basically of the following three components

diams hydrology

diams inlet design and

diams conduit design

These components will be addressed individually However it is important to understandthat all three components must function together simultaneously You must evaluate thehydrology aspects with respect to both inlet design and conduit design

18of 39

Design Iteration Procedure

The following steps illustrate the activities in a single design iteration

Design Iteration ProcedureStep Action

Step 1 Prepare a system planStep 2 Base initial runoff computations on Rational Method and tabulate them in

Conduit Information tableStep 3 Locate inlets based on logic and hydraulic demand and configure the conduit

system

Step 1

Prepare a system plan

Prepare a system plan as discussed in Section 2 System Planning Effectively the exampleproblem is identified as delineated in the problem statement Ensure there are no ldquodeadrdquospots where the runoff has no outlet Establish the general location of inlets the laterals andthe trunk lines You must coordinate the logical location of the various system componentswith the component locations necessary to satisfy hydraulic demand In subsequent designiterations you may change any or all parts of the system configuration as necessary

a Establish the design parameters and criteriab Select materials and shapes to be usedc Assign the design frequencyd Identify utility intersections with respect to

bull locationbull typebull owner and probable disposition

e Identify detention facilities

19of 39

Step 2

Base initial runoff computations on the Rational Method and tabulate them in ConduitInformation table The first four columns of this tabulation are self-explanatory The totalCA as shown in the fifth column is computed by multiplying each incremental area by itscorresponding coefficient of runoff and summing these incremental products As anexample the total CA for drainage area A1 is computed as follows

Type Hectares C CAPaved 010 x 085 = 0085Residential 069 x 055 = 0380TOTALS 079 0465

20of 39

Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

A1 Curb 069010

055085

0465 75 100 14793 0191

A2 SGrate 006 070 0042 20 100 14793 0017B1 Slot 011 085 0094 32 100 14793 0038C1 Curb 078

014050085 0509 145 145 12451 0176

A3 SGrate 010 070 0070 20 100 14793 0029D1 Slot 014 085 0119 41 100 14793 0049E1 Slot 022 050 0110 50 100 14793 0045E2 Curb 042

011055085 0325 135 135 12896 0116

A4 Junc 000 000G1 Curb 041

011050085 0299 90 100 14793 0123

A5 SGrate 005 070 0035 20 100 14793 0014F1 Slot 009 085 0077 36 100 14793 0031H1 Curb 008

006055085 0095 60 100 14793 0039

H2 Curb 012022

055085 0253 65 100 14793 0104

I1 Slot 032007

055085 0236 80 100 14793 0097

21of 39

(continued) Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

K1 Grate 066013

040085 0375 150 150 12241 0127

J1 SCurb 043021

060085 0437 88 100 14793 0180

L1 Grate 030007

055085 0225 177 177 11234 0070

L2 Grate 024 085 0204 36 100 14793 0084L3 Grate 017 085 0145 30 100 14793 0059A6 Junc 000 000M1 SCurb 033 085 0281 42 100 14793 0115A7 SGrate 004 070 0028 20 100 14793 0012N1 SCurb 041 085 0349 70 100 14793 0143Offsite 018

149070085 1393 116 116 13852 0536

A8 Junc 000 000A9 SGrate 012 070 0084 34 100 14793 0035A10 Outfall 000 000

a In the Summary of Hydrologic Computations table note that the operating timeof concentration has a minimum value of 10 minutes (according to departmentpractice) However it is necessary to account for the smaller time of concentrationtherefore the actual time of concentration (minimum notwithstanding) is alsotabulated

b The rainfall intensity (I) is based on Equation F-5 where e = 078 b = 1422 and d= 82 For drainage area A1 the time of concentration is only 75 minutesTherefore using 10 minutes as a basis the rainfall intensity is calculated as 1479mmhr

If =b

tc + d( )e

Equation F-5where

If=rainfall intensity for frequency (mmhr)tc=time of concentration (min)e b d= empirical factors which are tabulated for each county in Texas

for frequencies of 2 5 10 25 50 and 100 years in Appendix Bc The peak discharge (Q) is determined by multiplying CA by I and 000278

(Equation F-6)

Q = C I A360

22of 39

Equation F-6whereQ =peak discharge (m3s)C =runoff coefficientI =rainfall intensity associated with a specific frequency (mmhr)A =area of the watershed (ha)

d For watershed A1 Q is 0191 m3sStep 3

Locate the inlets based on logic and hydraulic demand and configure the conduit systema Locate the inlets based on logic and hydraulic demand as outlined in Section 5

Storm Drain Inletsb Finally after locating the inlets (establishing the nodes for the storm drain system)

you can configure the conduit system

Tables F-7 to F-13 show the suggested tabular format for calculations in the design of theinlet system in this example Since the design process is iterative requiring adjustments andre-analysis until the design is optimized the examples shown are only a ldquosnapshotrdquo (or oneiteration) during the design process

Inlets On-Grade Explanation

C = =

=

C A

A

n nn

m

nn

m1

1

Equation F-7where

C=weighted runoff coefficientn=nth subaream=number of subareasCn=runoff coefficient for nth subareaAn=nth subarea size (ha)

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 16: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

16of 39

Conduit InformationIdentificationsUS DS

Length (m) US Soffit Elev (m)

A1 A2 20 256760B1 A2 20 256730A2 A3 100 256670C1 A3 20 256260D1 A3 20 256270A3 A4 20 256200E1 E2 90 256600E2 A4 20 256150A4 A5 75 256090G1 A5 20 255810F1 A5 25 255830A5 A6 75 255730J1 G1 25 255940H1 H2 125 255880I1 H2 60 255810H2 A6 57 255560L1 L2 95 256320K1 L2 55 256070L2 L3 86 255850L3 A6 20 255570A6 A7 56 255490M1 A7 20 255300N1 A7 18 255240A7 A8 60 255220A8 A9 104 254880A9 A10 40 254270

17of 39

General Given InformationDesign Frequency 5 years (20 chance of exceedance)Rainfall intensity factors e = 078 b = 1422 mm d = 82Curb height 015 mMinimum time of concentration 10 minutesMinimum curb inlet length 15 mMinimum slotted drain inlet length 6 mStandard grate inlets Parallel bars wtransverse rods

W = 05 m and L = 1 mGrate inlets on sag in median 05 m x 05 m square inlets bar area =

25 of grate area allowable pondeddepth = 06 m

Gutter depression for curb inlets 75 mmAllowable ponded width 36 m on Lone Star Blvd and 45 m on

Texas AveCurb inlets on sag slope = 00050 mm and 50 of

discharge on each side of inletOutfall tailwater elevation (2 yr) 254360 m

Required Design a storm drain system to accommodate the design discharge

Discussion The following example represents a single iteration of the design process It isone of a series of iterations that would require revision re-analysis and optimizationuntil a technically acceptable and economical design is accomplished

In a production design all design parameters and criteria must be met The illustration ofthe hydraulic grade line is for demonstration only Typically the hydraulic grade line isdeveloped as a last design step after the system has been optimized The next subsectionsoffer initial design process components and a design iteration procedure

Initial Design Process Components

The initial design process consists basically of the following three components

diams hydrology

diams inlet design and

diams conduit design

These components will be addressed individually However it is important to understandthat all three components must function together simultaneously You must evaluate thehydrology aspects with respect to both inlet design and conduit design

18of 39

Design Iteration Procedure

The following steps illustrate the activities in a single design iteration

Design Iteration ProcedureStep Action

Step 1 Prepare a system planStep 2 Base initial runoff computations on Rational Method and tabulate them in

Conduit Information tableStep 3 Locate inlets based on logic and hydraulic demand and configure the conduit

system

Step 1

Prepare a system plan

Prepare a system plan as discussed in Section 2 System Planning Effectively the exampleproblem is identified as delineated in the problem statement Ensure there are no ldquodeadrdquospots where the runoff has no outlet Establish the general location of inlets the laterals andthe trunk lines You must coordinate the logical location of the various system componentswith the component locations necessary to satisfy hydraulic demand In subsequent designiterations you may change any or all parts of the system configuration as necessary

a Establish the design parameters and criteriab Select materials and shapes to be usedc Assign the design frequencyd Identify utility intersections with respect to

bull locationbull typebull owner and probable disposition

e Identify detention facilities

19of 39

Step 2

Base initial runoff computations on the Rational Method and tabulate them in ConduitInformation table The first four columns of this tabulation are self-explanatory The totalCA as shown in the fifth column is computed by multiplying each incremental area by itscorresponding coefficient of runoff and summing these incremental products As anexample the total CA for drainage area A1 is computed as follows

Type Hectares C CAPaved 010 x 085 = 0085Residential 069 x 055 = 0380TOTALS 079 0465

20of 39

Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

A1 Curb 069010

055085

0465 75 100 14793 0191

A2 SGrate 006 070 0042 20 100 14793 0017B1 Slot 011 085 0094 32 100 14793 0038C1 Curb 078

014050085 0509 145 145 12451 0176

A3 SGrate 010 070 0070 20 100 14793 0029D1 Slot 014 085 0119 41 100 14793 0049E1 Slot 022 050 0110 50 100 14793 0045E2 Curb 042

011055085 0325 135 135 12896 0116

A4 Junc 000 000G1 Curb 041

011050085 0299 90 100 14793 0123

A5 SGrate 005 070 0035 20 100 14793 0014F1 Slot 009 085 0077 36 100 14793 0031H1 Curb 008

006055085 0095 60 100 14793 0039

H2 Curb 012022

055085 0253 65 100 14793 0104

I1 Slot 032007

055085 0236 80 100 14793 0097

21of 39

(continued) Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

K1 Grate 066013

040085 0375 150 150 12241 0127

J1 SCurb 043021

060085 0437 88 100 14793 0180

L1 Grate 030007

055085 0225 177 177 11234 0070

L2 Grate 024 085 0204 36 100 14793 0084L3 Grate 017 085 0145 30 100 14793 0059A6 Junc 000 000M1 SCurb 033 085 0281 42 100 14793 0115A7 SGrate 004 070 0028 20 100 14793 0012N1 SCurb 041 085 0349 70 100 14793 0143Offsite 018

149070085 1393 116 116 13852 0536

A8 Junc 000 000A9 SGrate 012 070 0084 34 100 14793 0035A10 Outfall 000 000

a In the Summary of Hydrologic Computations table note that the operating timeof concentration has a minimum value of 10 minutes (according to departmentpractice) However it is necessary to account for the smaller time of concentrationtherefore the actual time of concentration (minimum notwithstanding) is alsotabulated

b The rainfall intensity (I) is based on Equation F-5 where e = 078 b = 1422 and d= 82 For drainage area A1 the time of concentration is only 75 minutesTherefore using 10 minutes as a basis the rainfall intensity is calculated as 1479mmhr

If =b

tc + d( )e

Equation F-5where

If=rainfall intensity for frequency (mmhr)tc=time of concentration (min)e b d= empirical factors which are tabulated for each county in Texas

for frequencies of 2 5 10 25 50 and 100 years in Appendix Bc The peak discharge (Q) is determined by multiplying CA by I and 000278

(Equation F-6)

Q = C I A360

22of 39

Equation F-6whereQ =peak discharge (m3s)C =runoff coefficientI =rainfall intensity associated with a specific frequency (mmhr)A =area of the watershed (ha)

d For watershed A1 Q is 0191 m3sStep 3

Locate the inlets based on logic and hydraulic demand and configure the conduit systema Locate the inlets based on logic and hydraulic demand as outlined in Section 5

Storm Drain Inletsb Finally after locating the inlets (establishing the nodes for the storm drain system)

you can configure the conduit system

Tables F-7 to F-13 show the suggested tabular format for calculations in the design of theinlet system in this example Since the design process is iterative requiring adjustments andre-analysis until the design is optimized the examples shown are only a ldquosnapshotrdquo (or oneiteration) during the design process

Inlets On-Grade Explanation

C = =

=

C A

A

n nn

m

nn

m1

1

Equation F-7where

C=weighted runoff coefficientn=nth subaream=number of subareasCn=runoff coefficient for nth subareaAn=nth subarea size (ha)

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 17: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

17of 39

General Given InformationDesign Frequency 5 years (20 chance of exceedance)Rainfall intensity factors e = 078 b = 1422 mm d = 82Curb height 015 mMinimum time of concentration 10 minutesMinimum curb inlet length 15 mMinimum slotted drain inlet length 6 mStandard grate inlets Parallel bars wtransverse rods

W = 05 m and L = 1 mGrate inlets on sag in median 05 m x 05 m square inlets bar area =

25 of grate area allowable pondeddepth = 06 m

Gutter depression for curb inlets 75 mmAllowable ponded width 36 m on Lone Star Blvd and 45 m on

Texas AveCurb inlets on sag slope = 00050 mm and 50 of

discharge on each side of inletOutfall tailwater elevation (2 yr) 254360 m

Required Design a storm drain system to accommodate the design discharge

Discussion The following example represents a single iteration of the design process It isone of a series of iterations that would require revision re-analysis and optimizationuntil a technically acceptable and economical design is accomplished

In a production design all design parameters and criteria must be met The illustration ofthe hydraulic grade line is for demonstration only Typically the hydraulic grade line isdeveloped as a last design step after the system has been optimized The next subsectionsoffer initial design process components and a design iteration procedure

Initial Design Process Components

The initial design process consists basically of the following three components

diams hydrology

diams inlet design and

diams conduit design

These components will be addressed individually However it is important to understandthat all three components must function together simultaneously You must evaluate thehydrology aspects with respect to both inlet design and conduit design

18of 39

Design Iteration Procedure

The following steps illustrate the activities in a single design iteration

Design Iteration ProcedureStep Action

Step 1 Prepare a system planStep 2 Base initial runoff computations on Rational Method and tabulate them in

Conduit Information tableStep 3 Locate inlets based on logic and hydraulic demand and configure the conduit

system

Step 1

Prepare a system plan

Prepare a system plan as discussed in Section 2 System Planning Effectively the exampleproblem is identified as delineated in the problem statement Ensure there are no ldquodeadrdquospots where the runoff has no outlet Establish the general location of inlets the laterals andthe trunk lines You must coordinate the logical location of the various system componentswith the component locations necessary to satisfy hydraulic demand In subsequent designiterations you may change any or all parts of the system configuration as necessary

a Establish the design parameters and criteriab Select materials and shapes to be usedc Assign the design frequencyd Identify utility intersections with respect to

bull locationbull typebull owner and probable disposition

e Identify detention facilities

19of 39

Step 2

Base initial runoff computations on the Rational Method and tabulate them in ConduitInformation table The first four columns of this tabulation are self-explanatory The totalCA as shown in the fifth column is computed by multiplying each incremental area by itscorresponding coefficient of runoff and summing these incremental products As anexample the total CA for drainage area A1 is computed as follows

Type Hectares C CAPaved 010 x 085 = 0085Residential 069 x 055 = 0380TOTALS 079 0465

20of 39

Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

A1 Curb 069010

055085

0465 75 100 14793 0191

A2 SGrate 006 070 0042 20 100 14793 0017B1 Slot 011 085 0094 32 100 14793 0038C1 Curb 078

014050085 0509 145 145 12451 0176

A3 SGrate 010 070 0070 20 100 14793 0029D1 Slot 014 085 0119 41 100 14793 0049E1 Slot 022 050 0110 50 100 14793 0045E2 Curb 042

011055085 0325 135 135 12896 0116

A4 Junc 000 000G1 Curb 041

011050085 0299 90 100 14793 0123

A5 SGrate 005 070 0035 20 100 14793 0014F1 Slot 009 085 0077 36 100 14793 0031H1 Curb 008

006055085 0095 60 100 14793 0039

H2 Curb 012022

055085 0253 65 100 14793 0104

I1 Slot 032007

055085 0236 80 100 14793 0097

21of 39

(continued) Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

K1 Grate 066013

040085 0375 150 150 12241 0127

J1 SCurb 043021

060085 0437 88 100 14793 0180

L1 Grate 030007

055085 0225 177 177 11234 0070

L2 Grate 024 085 0204 36 100 14793 0084L3 Grate 017 085 0145 30 100 14793 0059A6 Junc 000 000M1 SCurb 033 085 0281 42 100 14793 0115A7 SGrate 004 070 0028 20 100 14793 0012N1 SCurb 041 085 0349 70 100 14793 0143Offsite 018

149070085 1393 116 116 13852 0536

A8 Junc 000 000A9 SGrate 012 070 0084 34 100 14793 0035A10 Outfall 000 000

a In the Summary of Hydrologic Computations table note that the operating timeof concentration has a minimum value of 10 minutes (according to departmentpractice) However it is necessary to account for the smaller time of concentrationtherefore the actual time of concentration (minimum notwithstanding) is alsotabulated

b The rainfall intensity (I) is based on Equation F-5 where e = 078 b = 1422 and d= 82 For drainage area A1 the time of concentration is only 75 minutesTherefore using 10 minutes as a basis the rainfall intensity is calculated as 1479mmhr

If =b

tc + d( )e

Equation F-5where

If=rainfall intensity for frequency (mmhr)tc=time of concentration (min)e b d= empirical factors which are tabulated for each county in Texas

for frequencies of 2 5 10 25 50 and 100 years in Appendix Bc The peak discharge (Q) is determined by multiplying CA by I and 000278

(Equation F-6)

Q = C I A360

22of 39

Equation F-6whereQ =peak discharge (m3s)C =runoff coefficientI =rainfall intensity associated with a specific frequency (mmhr)A =area of the watershed (ha)

d For watershed A1 Q is 0191 m3sStep 3

Locate the inlets based on logic and hydraulic demand and configure the conduit systema Locate the inlets based on logic and hydraulic demand as outlined in Section 5

Storm Drain Inletsb Finally after locating the inlets (establishing the nodes for the storm drain system)

you can configure the conduit system

Tables F-7 to F-13 show the suggested tabular format for calculations in the design of theinlet system in this example Since the design process is iterative requiring adjustments andre-analysis until the design is optimized the examples shown are only a ldquosnapshotrdquo (or oneiteration) during the design process

Inlets On-Grade Explanation

C = =

=

C A

A

n nn

m

nn

m1

1

Equation F-7where

C=weighted runoff coefficientn=nth subaream=number of subareasCn=runoff coefficient for nth subareaAn=nth subarea size (ha)

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 18: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

18of 39

Design Iteration Procedure

The following steps illustrate the activities in a single design iteration

Design Iteration ProcedureStep Action

Step 1 Prepare a system planStep 2 Base initial runoff computations on Rational Method and tabulate them in

Conduit Information tableStep 3 Locate inlets based on logic and hydraulic demand and configure the conduit

system

Step 1

Prepare a system plan

Prepare a system plan as discussed in Section 2 System Planning Effectively the exampleproblem is identified as delineated in the problem statement Ensure there are no ldquodeadrdquospots where the runoff has no outlet Establish the general location of inlets the laterals andthe trunk lines You must coordinate the logical location of the various system componentswith the component locations necessary to satisfy hydraulic demand In subsequent designiterations you may change any or all parts of the system configuration as necessary

a Establish the design parameters and criteriab Select materials and shapes to be usedc Assign the design frequencyd Identify utility intersections with respect to

bull locationbull typebull owner and probable disposition

e Identify detention facilities

19of 39

Step 2

Base initial runoff computations on the Rational Method and tabulate them in ConduitInformation table The first four columns of this tabulation are self-explanatory The totalCA as shown in the fifth column is computed by multiplying each incremental area by itscorresponding coefficient of runoff and summing these incremental products As anexample the total CA for drainage area A1 is computed as follows

Type Hectares C CAPaved 010 x 085 = 0085Residential 069 x 055 = 0380TOTALS 079 0465

20of 39

Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

A1 Curb 069010

055085

0465 75 100 14793 0191

A2 SGrate 006 070 0042 20 100 14793 0017B1 Slot 011 085 0094 32 100 14793 0038C1 Curb 078

014050085 0509 145 145 12451 0176

A3 SGrate 010 070 0070 20 100 14793 0029D1 Slot 014 085 0119 41 100 14793 0049E1 Slot 022 050 0110 50 100 14793 0045E2 Curb 042

011055085 0325 135 135 12896 0116

A4 Junc 000 000G1 Curb 041

011050085 0299 90 100 14793 0123

A5 SGrate 005 070 0035 20 100 14793 0014F1 Slot 009 085 0077 36 100 14793 0031H1 Curb 008

006055085 0095 60 100 14793 0039

H2 Curb 012022

055085 0253 65 100 14793 0104

I1 Slot 032007

055085 0236 80 100 14793 0097

21of 39

(continued) Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

K1 Grate 066013

040085 0375 150 150 12241 0127

J1 SCurb 043021

060085 0437 88 100 14793 0180

L1 Grate 030007

055085 0225 177 177 11234 0070

L2 Grate 024 085 0204 36 100 14793 0084L3 Grate 017 085 0145 30 100 14793 0059A6 Junc 000 000M1 SCurb 033 085 0281 42 100 14793 0115A7 SGrate 004 070 0028 20 100 14793 0012N1 SCurb 041 085 0349 70 100 14793 0143Offsite 018

149070085 1393 116 116 13852 0536

A8 Junc 000 000A9 SGrate 012 070 0084 34 100 14793 0035A10 Outfall 000 000

a In the Summary of Hydrologic Computations table note that the operating timeof concentration has a minimum value of 10 minutes (according to departmentpractice) However it is necessary to account for the smaller time of concentrationtherefore the actual time of concentration (minimum notwithstanding) is alsotabulated

b The rainfall intensity (I) is based on Equation F-5 where e = 078 b = 1422 and d= 82 For drainage area A1 the time of concentration is only 75 minutesTherefore using 10 minutes as a basis the rainfall intensity is calculated as 1479mmhr

If =b

tc + d( )e

Equation F-5where

If=rainfall intensity for frequency (mmhr)tc=time of concentration (min)e b d= empirical factors which are tabulated for each county in Texas

for frequencies of 2 5 10 25 50 and 100 years in Appendix Bc The peak discharge (Q) is determined by multiplying CA by I and 000278

(Equation F-6)

Q = C I A360

22of 39

Equation F-6whereQ =peak discharge (m3s)C =runoff coefficientI =rainfall intensity associated with a specific frequency (mmhr)A =area of the watershed (ha)

d For watershed A1 Q is 0191 m3sStep 3

Locate the inlets based on logic and hydraulic demand and configure the conduit systema Locate the inlets based on logic and hydraulic demand as outlined in Section 5

Storm Drain Inletsb Finally after locating the inlets (establishing the nodes for the storm drain system)

you can configure the conduit system

Tables F-7 to F-13 show the suggested tabular format for calculations in the design of theinlet system in this example Since the design process is iterative requiring adjustments andre-analysis until the design is optimized the examples shown are only a ldquosnapshotrdquo (or oneiteration) during the design process

Inlets On-Grade Explanation

C = =

=

C A

A

n nn

m

nn

m1

1

Equation F-7where

C=weighted runoff coefficientn=nth subaream=number of subareasCn=runoff coefficient for nth subareaAn=nth subarea size (ha)

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 19: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

19of 39

Step 2

Base initial runoff computations on the Rational Method and tabulate them in ConduitInformation table The first four columns of this tabulation are self-explanatory The totalCA as shown in the fifth column is computed by multiplying each incremental area by itscorresponding coefficient of runoff and summing these incremental products As anexample the total CA for drainage area A1 is computed as follows

Type Hectares C CAPaved 010 x 085 = 0085Residential 069 x 055 = 0380TOTALS 079 0465

20of 39

Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

A1 Curb 069010

055085

0465 75 100 14793 0191

A2 SGrate 006 070 0042 20 100 14793 0017B1 Slot 011 085 0094 32 100 14793 0038C1 Curb 078

014050085 0509 145 145 12451 0176

A3 SGrate 010 070 0070 20 100 14793 0029D1 Slot 014 085 0119 41 100 14793 0049E1 Slot 022 050 0110 50 100 14793 0045E2 Curb 042

011055085 0325 135 135 12896 0116

A4 Junc 000 000G1 Curb 041

011050085 0299 90 100 14793 0123

A5 SGrate 005 070 0035 20 100 14793 0014F1 Slot 009 085 0077 36 100 14793 0031H1 Curb 008

006055085 0095 60 100 14793 0039

H2 Curb 012022

055085 0253 65 100 14793 0104

I1 Slot 032007

055085 0236 80 100 14793 0097

21of 39

(continued) Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

K1 Grate 066013

040085 0375 150 150 12241 0127

J1 SCurb 043021

060085 0437 88 100 14793 0180

L1 Grate 030007

055085 0225 177 177 11234 0070

L2 Grate 024 085 0204 36 100 14793 0084L3 Grate 017 085 0145 30 100 14793 0059A6 Junc 000 000M1 SCurb 033 085 0281 42 100 14793 0115A7 SGrate 004 070 0028 20 100 14793 0012N1 SCurb 041 085 0349 70 100 14793 0143Offsite 018

149070085 1393 116 116 13852 0536

A8 Junc 000 000A9 SGrate 012 070 0084 34 100 14793 0035A10 Outfall 000 000

a In the Summary of Hydrologic Computations table note that the operating timeof concentration has a minimum value of 10 minutes (according to departmentpractice) However it is necessary to account for the smaller time of concentrationtherefore the actual time of concentration (minimum notwithstanding) is alsotabulated

b The rainfall intensity (I) is based on Equation F-5 where e = 078 b = 1422 and d= 82 For drainage area A1 the time of concentration is only 75 minutesTherefore using 10 minutes as a basis the rainfall intensity is calculated as 1479mmhr

If =b

tc + d( )e

Equation F-5where

If=rainfall intensity for frequency (mmhr)tc=time of concentration (min)e b d= empirical factors which are tabulated for each county in Texas

for frequencies of 2 5 10 25 50 and 100 years in Appendix Bc The peak discharge (Q) is determined by multiplying CA by I and 000278

(Equation F-6)

Q = C I A360

22of 39

Equation F-6whereQ =peak discharge (m3s)C =runoff coefficientI =rainfall intensity associated with a specific frequency (mmhr)A =area of the watershed (ha)

d For watershed A1 Q is 0191 m3sStep 3

Locate the inlets based on logic and hydraulic demand and configure the conduit systema Locate the inlets based on logic and hydraulic demand as outlined in Section 5

Storm Drain Inletsb Finally after locating the inlets (establishing the nodes for the storm drain system)

you can configure the conduit system

Tables F-7 to F-13 show the suggested tabular format for calculations in the design of theinlet system in this example Since the design process is iterative requiring adjustments andre-analysis until the design is optimized the examples shown are only a ldquosnapshotrdquo (or oneiteration) during the design process

Inlets On-Grade Explanation

C = =

=

C A

A

n nn

m

nn

m1

1

Equation F-7where

C=weighted runoff coefficientn=nth subaream=number of subareasCn=runoff coefficient for nth subareaAn=nth subarea size (ha)

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 20: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

20of 39

Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

A1 Curb 069010

055085

0465 75 100 14793 0191

A2 SGrate 006 070 0042 20 100 14793 0017B1 Slot 011 085 0094 32 100 14793 0038C1 Curb 078

014050085 0509 145 145 12451 0176

A3 SGrate 010 070 0070 20 100 14793 0029D1 Slot 014 085 0119 41 100 14793 0049E1 Slot 022 050 0110 50 100 14793 0045E2 Curb 042

011055085 0325 135 135 12896 0116

A4 Junc 000 000G1 Curb 041

011050085 0299 90 100 14793 0123

A5 SGrate 005 070 0035 20 100 14793 0014F1 Slot 009 085 0077 36 100 14793 0031H1 Curb 008

006055085 0095 60 100 14793 0039

H2 Curb 012022

055085 0253 65 100 14793 0104

I1 Slot 032007

055085 0236 80 100 14793 0097

21of 39

(continued) Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

K1 Grate 066013

040085 0375 150 150 12241 0127

J1 SCurb 043021

060085 0437 88 100 14793 0180

L1 Grate 030007

055085 0225 177 177 11234 0070

L2 Grate 024 085 0204 36 100 14793 0084L3 Grate 017 085 0145 30 100 14793 0059A6 Junc 000 000M1 SCurb 033 085 0281 42 100 14793 0115A7 SGrate 004 070 0028 20 100 14793 0012N1 SCurb 041 085 0349 70 100 14793 0143Offsite 018

149070085 1393 116 116 13852 0536

A8 Junc 000 000A9 SGrate 012 070 0084 34 100 14793 0035A10 Outfall 000 000

a In the Summary of Hydrologic Computations table note that the operating timeof concentration has a minimum value of 10 minutes (according to departmentpractice) However it is necessary to account for the smaller time of concentrationtherefore the actual time of concentration (minimum notwithstanding) is alsotabulated

b The rainfall intensity (I) is based on Equation F-5 where e = 078 b = 1422 and d= 82 For drainage area A1 the time of concentration is only 75 minutesTherefore using 10 minutes as a basis the rainfall intensity is calculated as 1479mmhr

If =b

tc + d( )e

Equation F-5where

If=rainfall intensity for frequency (mmhr)tc=time of concentration (min)e b d= empirical factors which are tabulated for each county in Texas

for frequencies of 2 5 10 25 50 and 100 years in Appendix Bc The peak discharge (Q) is determined by multiplying CA by I and 000278

(Equation F-6)

Q = C I A360

22of 39

Equation F-6whereQ =peak discharge (m3s)C =runoff coefficientI =rainfall intensity associated with a specific frequency (mmhr)A =area of the watershed (ha)

d For watershed A1 Q is 0191 m3sStep 3

Locate the inlets based on logic and hydraulic demand and configure the conduit systema Locate the inlets based on logic and hydraulic demand as outlined in Section 5

Storm Drain Inletsb Finally after locating the inlets (establishing the nodes for the storm drain system)

you can configure the conduit system

Tables F-7 to F-13 show the suggested tabular format for calculations in the design of theinlet system in this example Since the design process is iterative requiring adjustments andre-analysis until the design is optimized the examples shown are only a ldquosnapshotrdquo (or oneiteration) during the design process

Inlets On-Grade Explanation

C = =

=

C A

A

n nn

m

nn

m1

1

Equation F-7where

C=weighted runoff coefficientn=nth subaream=number of subareasCn=runoff coefficient for nth subareaAn=nth subarea size (ha)

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 21: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

21of 39

(continued) Summary of Hydrologic ComputationsIdentification Type Area

(ha)C CA (ha) Actual

Time(min)

tc (min) I(mmhr)

Q (m3s)

K1 Grate 066013

040085 0375 150 150 12241 0127

J1 SCurb 043021

060085 0437 88 100 14793 0180

L1 Grate 030007

055085 0225 177 177 11234 0070

L2 Grate 024 085 0204 36 100 14793 0084L3 Grate 017 085 0145 30 100 14793 0059A6 Junc 000 000M1 SCurb 033 085 0281 42 100 14793 0115A7 SGrate 004 070 0028 20 100 14793 0012N1 SCurb 041 085 0349 70 100 14793 0143Offsite 018

149070085 1393 116 116 13852 0536

A8 Junc 000 000A9 SGrate 012 070 0084 34 100 14793 0035A10 Outfall 000 000

a In the Summary of Hydrologic Computations table note that the operating timeof concentration has a minimum value of 10 minutes (according to departmentpractice) However it is necessary to account for the smaller time of concentrationtherefore the actual time of concentration (minimum notwithstanding) is alsotabulated

b The rainfall intensity (I) is based on Equation F-5 where e = 078 b = 1422 and d= 82 For drainage area A1 the time of concentration is only 75 minutesTherefore using 10 minutes as a basis the rainfall intensity is calculated as 1479mmhr

If =b

tc + d( )e

Equation F-5where

If=rainfall intensity for frequency (mmhr)tc=time of concentration (min)e b d= empirical factors which are tabulated for each county in Texas

for frequencies of 2 5 10 25 50 and 100 years in Appendix Bc The peak discharge (Q) is determined by multiplying CA by I and 000278

(Equation F-6)

Q = C I A360

22of 39

Equation F-6whereQ =peak discharge (m3s)C =runoff coefficientI =rainfall intensity associated with a specific frequency (mmhr)A =area of the watershed (ha)

d For watershed A1 Q is 0191 m3sStep 3

Locate the inlets based on logic and hydraulic demand and configure the conduit systema Locate the inlets based on logic and hydraulic demand as outlined in Section 5

Storm Drain Inletsb Finally after locating the inlets (establishing the nodes for the storm drain system)

you can configure the conduit system

Tables F-7 to F-13 show the suggested tabular format for calculations in the design of theinlet system in this example Since the design process is iterative requiring adjustments andre-analysis until the design is optimized the examples shown are only a ldquosnapshotrdquo (or oneiteration) during the design process

Inlets On-Grade Explanation

C = =

=

C A

A

n nn

m

nn

m1

1

Equation F-7where

C=weighted runoff coefficientn=nth subaream=number of subareasCn=runoff coefficient for nth subareaAn=nth subarea size (ha)

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 22: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

22of 39

Equation F-6whereQ =peak discharge (m3s)C =runoff coefficientI =rainfall intensity associated with a specific frequency (mmhr)A =area of the watershed (ha)

d For watershed A1 Q is 0191 m3sStep 3

Locate the inlets based on logic and hydraulic demand and configure the conduit systema Locate the inlets based on logic and hydraulic demand as outlined in Section 5

Storm Drain Inletsb Finally after locating the inlets (establishing the nodes for the storm drain system)

you can configure the conduit system

Tables F-7 to F-13 show the suggested tabular format for calculations in the design of theinlet system in this example Since the design process is iterative requiring adjustments andre-analysis until the design is optimized the examples shown are only a ldquosnapshotrdquo (or oneiteration) during the design process

Inlets On-Grade Explanation

C = =

=

C A

A

n nn

m

nn

m1

1

Equation F-7where

C=weighted runoff coefficientn=nth subaream=number of subareasCn=runoff coefficient for nth subareaAn=nth subarea size (ha)

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 23: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

23of 39

On Grade Inlet CalculationsOn-Grade Inlets

1ID

2Type

3Area

ha

4Wtd

C

5CAha

6Actual tc

min

7InletTimemin

8Intensitymmhr

9Q

m3s

10COm3s

11Total

Qm3s

121Sx

mm

13Slopemm

14ym

15Tm

16am

17E

A1 Curb 079 059 046 75 100 14793 0191 0000 0191 24 00050 0132 316 0075C1 Curb 092 055 051 145 145 12451 0176 0010 0186 32 00060 0113 362 0075E1 Slot 022 050 011 50 100 14793 0045 0000 0045 48 00065 0056 270 031E2 Curb 053 061 032 135 135 12896 0116 0002 0118 48 00060 0082 393 0075G1 Curb 052 057 030 90 100 14793 0123 0005 0128 32 00060 0098 314 0075K1 Grate 079 047 037 150 150 12241 0127 0000 0127 48 00040 0091 436L1 Grate 037 061 022 177 177 11234 0070 0000 0070 48 00040 0073 349L2 Grate 024 085 020 36 100 14793 0084 0027 0111 48 00040 0086 415L3 Grate 017 085 014 30 100 14793 0059 0050 0110 48 00040 0086 413B1 Slot 011 085 009 32 100 14793 0038 0000 0038 24 00050 0072 173 032D1 Slot 014 085 012 41 100 14793 0049 0000 0049 32 00060 0069 219 033F1 Slot 009 085 008 36 100 14793 0031 0000 0031 32 00060 0058 186 033I1 Slot 039 060 024 80 100 14793 0097 0000 0097 48 00030 0087 416 031H1 Curb 014 068 010 60 100 14793 0039 0000 0039 48 00030 0062 296 0075H2 Curb 034 074 025 65 100 14793 0104 0009 0113 48 00050 0083 399 0075

On Grade Inlet Calculations (part 2)On-Grade Inlets (Continued)ID 18

Wm

19L grate

m

20Lr curb

m

21Lr slot

m

22La

m

23LaLr

24aW

25COm3s

26CO

to

27Qi

m3s

28Remarks

A1 05 370 3 081 057 0010 C1 0181 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

C1 05 418 6 143 066 0000 E2 0186 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

E1 733 6 082 0002 E2 0043E2 05 365 3 082 092 0005 G1 0113 see the Correction Factor K2 for Angle of

Flow Attack table for CURB inlet calculationsG1 05 340 3 088 076 0003 J1 0125 see the Correction Factor K2 for Angle of

Flow Attack table CURB inlet calculationsK1 05 1 0060 J1 0068 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsL1 05 1 0027 L2 0043 see the Correction Factor K3 for Bed

Condition table for GRATE calculationsL2 05 1 0050 L3 0061 see the Correction Factor K3 for Bed

Condition table GRATE calculationsL3 05 1 0049 M1 0060 CO to SAG see the Correction Factor K3 for

Bed Condition table for GRATE calcsB1 330 6 182 0000 D1 0038D1 472 6 127 0000 F1 0049F1 388 6 155 0000 H2 0031I1 806 6 074 0008 H2 0089

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 24: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

24of 39

H1 05 165 15 091 122 0001 H2 0039 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

H2 05 340 45 132 090 0000 N1 0113 see the Correction Factor K2 for Angle ofFlow Attack table for CURB inlet calculations

The following procedure refers to the format of the On Grade Inlet Calculations table part1 and part 2

Column 1 Identify all inlets with a unique name Here is a suggested system ofalphanumeric characters that relates to each storm drain line This system is compatiblewith the system of identification used in WinStorm for storm drain system design andanalysis The first inlet is identified as A1 It is useful to identify the longest conduitline A Nodes on that line may be numbered in order from either direction Forexample in WinStorm the first inlet would carry an identification of A1

Column 2 This column indicates the type of inlet used at each location For example atnode A1 a curb opening inlet is used (described here as ldquoCurbrdquo)

Column 3 This column shows the drainage area size in hectares

Column 4 Here is the weighted runoff coefficient for the identified drainage area Theweighted runoff coefficient is calculated using Equation F-7

Column 5 This is the product of the weighted runoff coefficient and the drainage areaThis value is the total CA for the watershed (also tabulated in the Conduit Informationtable)

Column 6 This column shows the actual time of concentration for the drainage area

Column 7 Here is the time of concentration used for the derivation of the rainfall intensityUse the actual time of concentration or 10 minutes whichever is greater

Column 8 Rainfall intensity for frequency f is based on the intensity formula (Equation F-5)

Column 9 This is the peak discharge for the subject drainage area calculated using theRational Equation (Q = C I A360 or Q = I Σ(CA) 360)

Column 10 The carry-over in this column is the rate of discharge which has passed by thelast upstream (gutter) inlet Always accommodate the rate of carry-over from any inletCarry-over that is not accommodated can be very troublesome and can cause severetraffic interruption problems Any carry-over rate not picked up by another inletrequires some explanation of its disposal in the Remarks column (Column 30)

Column 11 The runoff from the subject watershed and any pertinent carry-over equals thetotal runoff Q

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 25: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

25of 39

Column 12 The reciprocal of the cross slope 1Sx (mm) is determined from the proposedroadway cross sections

Column 13 The longitudinal gutter slope S (mm) is determined from the proposedroadway profile

Column 14 The depth of flow y is calculated in this column with Equation 10-1 Thedepth of flow is used forbull computation of ponded width for gutter flowbull determination of length required for total interception in curb opening inlets on-

gradebull details of flow interception for grate inlets on-grade

Column 15 The ponded width (T) is the product of 1Sx and y (Columns 12 and 14) andshould not exceed the limits given in the design criteria In the example problem themaximum permissible ponded width is 36 meters for the section of Lone Star Blvdand 45 meters for Texas Avenue If the allowable ponded width is exceeded the usualadjustment is to space the inlets closer together This adjustment effectively removesthe water from the surface at more frequent intervals and limits the accumulateddischarge On the other hand if the width of ponding is significantly less than theallowable ponded width you may find it economical to reduce the number of inlets inthe system

Column 16 The curb opening gutter depression (a) is expressed in meters (see Figure 10-14)

Column 17 The value of E is an exponent which is applicable to the calculation of totalinterception length for on-grade slotted drain inlets See Equation 10-21

Column 18 The value of W is the width of grate (meters) for an on-grade grate inlet or thedepression width for an on-grade curb inlet

Column 19 The value of L is the length of an on-grade grate inlet (meters) You thedesigner must select this value

Column 20 The length of on-grade curb opening inlet that is required to intercept all of theflow (Lr) is determined through the following steps (see the following table)

On Grade Curb Inlet Calculationsa

IDb

Aw

m2

cPw

m

dKw

eAo

m2

fPo

m

gKo

hEo

iSe

jLr

mA1 0079 0509 1531 0147 2658 1425 0518 0119 370C1 0071 0508 1284 0152 3115 1346 0488 0104 418E2 0057 0507 0887 0123 3434 0888 0500 0096 365G1 0064 0508 1071 0109 2644 0870 0552 0114 340H1 0047 0507 0640 0063 2456 0363 0638 0116 165

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 26: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

26of 39

H2 0058 0507 0904 0127 3495 0931 0493 0095 340

Column 20a This column identifies the inlet

Column 20b The area of the depressed portion of the gutter (AW) is expressed insquare meters and is calculated with Equation F-8

A = W S (T - W2

) + 12 aWW x

Equation F-8where Sx = cross slope (mm)

T = calculated ponded width (m)W = depression width for an on-grade curb inlet (m)

a = curb opening depression width (m)

Column 20c The wetted perimeter of the depressed portion of the gutter (PW) inmeters is determined with Equation F-9 The top of the curb opening is ignored here

( )P = WS + a W x2 + W2

Equation F-9

Column 20d The conveyance of the depressed gutter section (KW) is calculated withAW and PW substituted into Equation 10-8

Column 20e The area of the gutterroad beyond the depression width (AO) is expressedin square meters and is calculated with Equation F-10

A = S2 (T - W)O

x 2

Equation F-10

Column 20f The wetted perimeter of the portion of the gutter beyond the depression(PO) in meters is determined with the following approximation (because Sx is usuallysmall)

P = T - WOEquation F-11

Column 20g The conveyance of the gutter section beyond the depression (KO) iscalculated with AO and PO inserted into Equation 10-8

Column 20h EO the ratio of depression flow to total flow is calculated using Equation10-7

Column 20i The equivalent cross slope (Se) for a depressed curb-opening inlet isdetermined with Equation 10-9

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 27: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

27of 39

Column 20j The length of the on-grade curb-opening inlet that is required to interceptall of the flow (Lr) given in meters is found with Equation 10-9

Column 21 The length of an on-grade slotted drain inlet necessary to intercept all of theflow Lr) is determined by use of Equation 10-20

Column 22 The value in this column represents the actual length to be installed for either acurb opening inlet or a slotted drain inlet This will ordinarily be a nominal (standard)length If there is to be no carryover for an on-grade inlet this value will be greaterthan the value in Column 20 or Column 21 (depending on the inlet type) If there iscarryover for an on-grade inlet the inlet will be shorter and you should use the originalrequired length (for total interception) to calculate the intercepted discharge rate

Column 23 The ratio of La to Lr (Column 22 divided by either Column 20 or Column 21whichever is applicable) is used to calculate the interception rate for the designed inletIf the ratio is 100 or greater the inlet will intercept all of the flow and there will be nocarryover

Column 24 This column is the difference of Column 16 divided by Column 18 the ratio ofgutter depression (a) to gutter depression width (w) to calculate the interception rate forthe designed curb opening inlet This ratio is not applicable in calculations for slotteddrain inlets or grate inlets (on-grade)

Column 25 The carryover rate (CO) is computed directly for on-grade curbs usingEquation 10-11 or for slots using Equation 10-22 Equation 10-8 This will be zero ifthe actual inlet length is greater than the required length For a grate-on-grade firstdetermine the intercepted flow as discussed for Column 27 and subtract this value fromthe total discharge Carryover flow should usually not exceed about 30 percent of thetotal discharge approaching the inlet

Column 26 If there is carryover for the subject inlet you must select and consider adestination in subsequent calculations You must not ignore even small rates ofcarryover discharge The designated destination must be the nearest inlet accessible bythe carryover flow In the case of the curb opening inlet at node A1 the designateddestination is node C1

Column 27 The flow intercepted at an on-grade curb or slot is the total discharge minus thecarryover flow (Column 11ndashColumn 25) The On Grade Inlet Calculations tablerepresents calculations for grate-on-grade inlets Place the results of Column h of thetable in this column for grate-on-grade inlets The on-grade grate inlet dischargeinterception procedure follows that of on-grade curbs and slots discussed previouslythrough Column 19 The On Grade Grate Calculations table shows the remainingcalculations required to determine the rate of interception

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 28: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

28of 39

On Grade Grate Calculationsa

IDbEo

cvo

ms

dv

ms

eRf

fRs

gEf

hQi

m3s

iCOm3s

K1 0277 1984 0642 10 0358 0531 0068 0060L1 0338 1984 0553 10 0421 0608 0043 0027L2 0290 1984 0621 10 0372 0548 0061 0050L3 0292 1984 0619 10 0373 0550 0060 0049

Column 27a The inlet is identified in this column

Column 27b The ratio of frontal flow to total gutter flow (EO) is calculated withEquation 10-7 in the same manner as shown in the Summary of HydrologicComputations table for on-grade curbs but using a = 0

Column 27c The splash-over velocity (vO) is determined with the applicable equationin Equation 10-2 In this example a parallel grate is used thus

vO = 0224 + 2437Lndash0869L2 + 0192L3

where L is the length of the grate (m)

Column 27d The approach velocity in the gutter is found with Equation 10-25

Column 27e The ratio of the frontal flow intercepted to the total frontal flow (Rf) isequal to 10 if the splash-over velocity is greater than the approach velocity Equation10-23 is used to determine Rf if the splash-over velocity is less than the approachvelocity

Column 27f The ratio of side flow intercepted to total side flow (RS) is determinedwith Equation 10-27

Column 27g The efficiency of the grate (Ef) is based on Equation 10-28

Column 27h The interception rate of the inlet (Qi) is calculated with Equation 10-29

Column 27i The carryover rate is the difference between the actual discharge and theinterception rate

Column 28 The remarks column is often used forbull explanationsbull specific documentationbull qualifying statementsbull special calculations or references

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 29: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

29of 39

Calculation Explanation for Curb Opening Inlets in Sags

The following discussion refers to Tables F-11 and F-12 regarding the calculations for curbopening inlets

Curb Inlets on Sag CalculationsCurb Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3s

121Sx

13Tallow

m

14yallow

J1 SCurb 064 068 044 88 100 14793 0180 0063 0242 32 450 014M1 SCurb 033 085 028 42 100 14793 0115 0049 0165 32 360 011N1 SCurb 041 085 035 70 100 14793 0143 0000 0143 32 360 011

Curb Inlets on Sag Calculations (part 2)Curb Inlets on Sag (Continued)

15 16 17 18 19 20 21 22 23 24 25 26Left Side Right Side InletID

Slopemm

Q

ym

Tm

Slopemm

Q

ym

Tm

am

Wm

hm

Lreqrsquod

mJ1 00050 50 010 319 00050 50 010 319 008 05 0216 103M1 00050 50 009 276 00050 50 009 276 008 05 0188 072N1 00050 50 008 262 00050 50 008 262 008 05 0188 051

Columns 1 through 12 These columns are determined in the same manner as on-gradeinlets

Column 13 The allowable ponded width is given in the specifications at the beginning ofthis example

Column 14 The allowable ponded depth (yallow) is the lower of the curb height and thedepth calculated by multiplying the allowable ponded width by Sx = (Column 13 Column 12)

NOTE You must consider the approach flow to sag inlets in the evaluation of pondedwidths in the gutter Since you must observe the allowable ponded width it isnecessary to estimate curb and gutter flow widths from each direction to the inlet

Column 15 This column is used to show the gutter slope on the left side of the inlet

Column 16 Estimate the percentage of the total discharge that will enter the inlet from theleft side In this example the left side discharge is taken as one-half of the totaldischarge

Column 17 The depth of flow (y) is calculated with Equation 10-1 This should be lowerthan the allowable ponded depth in Column 14 otherwise a flanker inlet will be needed

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 30: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

30of 39

Column 18 The ponded width on the left side of the gutter is equal to the depth of flowdivided by Sx = (Column 17 Column 12) If this value exceeds the allowable pondedwidth a flanker inlet will be necessary on the left approach

NOTE Columns 19 through 22 are identical to Columns 15 through 18 except that theyapply to the right side of the inlet

Column 19 The inlet depression a (m) is given in the specifications for this example

Column 20 The lateral width of the inlet depression W (m) is used in the calculation ofthe required inlet length

Column 21 The allowable head on the inlet (h) is the sum of the allowable ponded depth(yallow) and the inlet depression a (Column 14 + Column 23)

Column 22 The required length of the curb is computed using Equation 10-17 At thispoint a standard size inlet would be chosen that meets or exceeds the required length

NOTE It is advisable to provide a safety factor of about 21 Use judgment relative to theanticipated type and quantity of debris that the inlet must accommodate

Calculation Explanation for Grate Inlets

The following procedure refers to Tables F-13 and F-14 Instead of attempting to size a gratefor this example w e examine a standard size inlet to determine whether it willaccommodate a given flow

Grate Inlets on Sag CalculationsGrate Inlets on Sag

1ID

2Type

3Area

ha

4Wtd C

5CAha

6Actual tc

min

7Inlet Time

min

8Intensitymmhr

9Q

m3s

10COm3s

11Total Q

m3sA2 SGrate 006 070 004 20 100 14793 0017 0000 0017A3 SGrate 010 070 007 20 100 14793 0029 0000 0029A5 SGrate 005 070 004 20 100 14793 0014 0000 0014A7 SGrate 004 070 003 20 100 14793 0012 0000 0012A9 SGrate 012 070 008 34 100 14793 0035 0000 0035

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 31: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

31of 39

Grate Inlets on Sag Calculations (part 2)Grate Inlets on Sag (Continued)

1ID

12hallow

m

13Pm

14Qw

m3s

15Am2

16Qo

m3s

17Capacity

m3s

18Remarks

A2 06 09 069 0094 0216 0216 Orifice control size OKA3 06 09 069 0094 0216 0216 Orifice control size OKA5 06 09 069 0094 0216 0216 Orifice control size OKA7 06 09 069 0094 0216 0216 Orifice control size OKA9 06 09 069 0094 0216 0216 Orifice control size OK

Columns 1 through 11 These columns are determined in the same manner as on-gradeinlets

Column 12 Since we use the grate inlets for this example in a median ditch area gutterponding computations are not applicable Separate calculations (not shown here) mustensure adequate capacity of the median ditch We give the allowable ponded depth(hallow) in the example problem specifications Since no depression is applied theallowable ponded depth of 06 m will be the allowable head on the median inlets

Column 13 The perimeter for a square inlet receiving flow from four sides is four times theside length minus the width of bars in the grate configuration (ie the available lengthfor flow to enter the inlet) Assuming a reduction of 02 m for bars the perimeter is 2ndash02 = 18 m Considering the potential for clogging assume 50 of this as a reasonablesafety factor giving an effective perimeter of 09 m

Column 14 The capacity of a grate operating as a weir (Qw) is calculated with Equation10-31

Column 15 The area of the parallel bars in this example comprises about 25 of the gratearea Thus the clear opening area of the inlet will be 75 of the total grate area giving0188 m2 Considering the potential for clogging reduce this by 50 to give aneffective area of 0094 m2

Column 16 The capacity of the inlet operating in orifice flow is computed with Equation10-32

Column 17 The capacity of the inlet is based on the minimum flow calculated in Columns14 and 16 For all of the inlets the capacity is larger than the total discharge indicatingthat the grate sizes will suffice

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 32: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

32of 39

Conduit Design Explanation

Tables F-15 and F-16 show the suggested tabular format for calculations in the developmentof the conduit system and this subsection describes the format

Conduit Design CalculationsFrom

IDTo ID Area

(hectares)CA Sum CA External

Time(min)

AccumTime(min)

TimeUsed(min)

Intensity(mmhr)

Discharge(m3s)

1 2 3 4 5 6 7 8 9 10A1 A2 079 046 046 75 100 14793 0191B1 A2 011 009 009 32 100 14793 0039A2 A3 006 004 060 20 77 100 14793 0247C1 A3 092 051 051 145 145 12451 0176D1 A3 014 012 012 41 100 14793 0049A3 A4 010 007 130 20 148 148 12340 0445E1 E2 022 011 011 50 100 14793 0045E2 A4 053 032 043 135 64 135 12896 0156A4 A5 000 000 173 149 149 12270 0591G1 A5 052 030 074 90 91 100 14793 0302F1 A5 009 008 008 36 100 14793 0031A5 A6 005 004 258 20 155 155 12024 0862J1 G1 064 044 044 88 100 14793 0180H1 H2 014 010 010 60 100 14793 0039I1 H2 039 024 024 80 100 14793 0097H2 A6 034 025 058 65 88 100 14793 0240L1 L2 037 022 022 177 177 11234 0070K1 L2 079 037 037 150 150 12241 0127L2 L3 024 020 080 36 190 190 10813 0241L3 A6 017 014 095 30 200 200 10510 0277A6 A7 000 000 411 202 202 10450 1194M1 A7 033 028 028 42 100 14793 0115N1 A7 041 035 035 70 100 14793 0143A7 A8 004 003 477 20 206 206 10340 1370Off A8 167 139 139 116 116 13852 0536A8 A9 000 000 616 210 210 10235 1753A9 A10 012 008 624 34 216 216 10074 1749

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 33: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

33of 39

Conduit Design Calculations (part 2)Fr

om ID

To ID

US

Sof

fit E

lev

(m)

DS

Sof

fit E

lev

(m)

Con

duit

Len

gth

(m)

Slop

e (

)

RC

P Si

ze R

equi

red

(mm

)

Nom

inal

Siz

e (m

m)

Uni

form

Dep

th (m

)

Vel

ocity

(ms

)

Tra

vel T

ime

(min

)

Tim

e at

end

of C

ondu

it(m

in)

Remarks1 2 11 12 13 14 15 16 17 18 19 20 21

A1 A2 256760 256670 20 0450 436 450 0341 148 02 77

B1 A2 256730 256670 20 0300 259 450 0146 086 04 36

A2 A3 256670 256200 100 0470 477 600 0315 165 10 87 CA = 046+009+004=060C1 A3 256260 256200 20 0300 457 600 0294 128 03 148D1 A3 256270 256200 20 0350 275 450 0159 097 03 44A3 A4 256200 256090 20 0550 577 600 0446 198 02 149 CA = 060+051+012+007=130E1 E2 256600 256150 90 0500 249 450 0139 108 14 64E2 A4 256150 256090 20 0300 436 450 0340 121 03 138 CA = 011+032=043A4 A5 256090 255730 75 0480 659 750 0466 205 06 155 CA = 130+043+000=173G1 A5 255810 255730 20 0400 530 600 0376 162 02 93 CA = 044+030=074F1 A5 255830 255730 25 0400 227 450 0127 092 05 41A5 A6 255730 255490 75 0320 819 900 0596 193 06 162 CA = 173+074+008+004=258J1 G1 255940 255810 25 0520 415 450 0306 156 03 91H1 H2 255880 255560 125 0256 268 450 0153 082 26 86I1 H2 255810 255560 60 0417 343 450 0221 124 08 88H2 A6 255560 255490 57 0123 607 750 0405 099 10 98 CA = 010+024+025=058L1 L2 256320 255850 95 0495 294 450 0176 122 13 190K1 L2 256070 255850 55 0400 383 450 0265 131 07 157L2 L3 255850 255570 86 0326 506 600 0347 142 10 200 CA = 022+037+020=080L3 A6 255570 255490 20 0400 513 600 0355 159 02 202 CA = 080+014=095A6 A7 255490 255220 56 0482 857 900 0653 241 04 206 CA = 258+058+095+000=411M1 A7 255300 255220 20 0400 369 450 0249 128 03 45N1 A7 255240 255220 18 0111 509 600 0351 083 04 74A7 A8 255220 254880 60 0567 875 900 0686 264 04 210 CA = 411+028+035+003=477Off A8 116 Inflow from external systemA8 A9 254880 254270 104 0587 954 1050 0693 289 06 216 CA = 477+140+000=617A9 A10 254270 254030 40 0600 949 1050 0687 291 02 218 CA = 617+008=624

Column 1 This column identifies the upstream node of the subject run (segment) Theidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

Column 2 This column identifies the downstream node of the subject run (segment) Thisidentification code should correspond to the inletjunction and associated watershedconsidered previously in the design process

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 34: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

34of 39

Column 3 This column contains the drainage area that is directly accommodated by theupstream inlet of the subject conduit Water enters the conduit system for the first timefrom this watershed Where there is no inlet at the upstream node (ie a manhole orjunction) the watershed area is listed as 000 hectares

This value is not used directly in the calculations for conduit design However the totalaccumulated watershed areas are ultimately needed for proper consideration of the tailwaterconditions Column 3 is a convenient place to tabulate the individual watersheds so that atotal of all watershed areas can be made later

Column 4 The value in this column is the product of the drainage area and weighted runoffcoefficient that is directly accommodated by the upstream inlet of the subject conduit

Column 5 The value in this column is a summation of the products of drainage area andassociated runoff coefficients from all areas that contribute runoff to the upstream nodeIt is useful and convenient to show the summation calculation or the contributing nodesin Column 21 (Remarks)

Column 6 This column shows the external time of concentration from the individualdrainage area that contributes flow directly to the inlet at the upstream end of thesubject run This will be carried over from Column 7 of the inlet calculations (Table F-5 ) Where there is no inlet at the upstream node there can be no time of concentration inthis column

This value will be compared to other times of concentration in the search for the longest(effective) time of concentration which will serve as the basis for the rainfall intensitycalculation

Column 7 This column contains the longest time of concentration approaching theupstream node of the subject run from the conduit system upstream shown in Column20 If the run is a lateral there will be no upstream runs and there will be no value forthis column

Column 8 The value of time of concentration shown in this column is the greatest of one ofthe followingbull time of concentration of surface flow to the inlet at the upstream node of the subject

run (Column 6)bull longest time of concentration approaching the upstream node of the subject run

from any incoming conduit at the upstream node (Column 7)bull minimum time of concentration to be used for derivation of rainfall intensity (In

department practice this value is taken as 10 minutes)

The value shown in Column 8 is used to derive the rainfall intensity to calculate thedischarge to be accommodated by the subject run

Column 9 The rainfall intensity in this column is based on the value of the longest time ofconcentration (or minimum time of concentration) indicated in Column 8 Equation F-5 is used for this calculation

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 35: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

35of 39

Column 10 This column contains the total discharge to be accommodated by the subjectrun This is done in accordance with Equation F-6 (ie 000278 times Column 9 timesColumn 5)

Column 11 The upstream soffit elevation of the location listed in Column 1 appears in thiscolumn

Column 12 The soffit elevation of the downstream location (Column 2) appears here

Column 13 This column shows the length of the run to be used for calculation of conduitslope and travel time (and ultimately the friction loss for hydraulic grade linedevelopment)

Column 14 The value in this column is the conduit slope calculated by dividing thedifference in soffit elevations by the conduit length The conduit slope is shown as apercentage for convenience but design equations require the slope value be in terms ofmm

Column 15 This column indicates the calculated required conduit size For circular pipeuse Equation 10-40 (RCP)

Column 16 The design dimension for the subject run appears here All calculations for thesubject run which follow this choice will use this dimension as a basis For non-pressure flow design this value should be larger than the size determined in Column 15

Column 17 The uniform depth in the pipe is shown in this column For circular conduitsthis value is determined by trial and error and is used in estimating the average velocityof flow in the conduit See the Average Velocity subsection in Section 1 of Chapter 6

Column 18 The average velocity of flow in the conduit is based on continuity (Equation10-41) assuming that the average depth of flow is uniform depth

Column 19 The travel time shown in this column is based on a division of run length byaverage velocity Divide this value by 60 to determine the time in minutes

Column 20 This column shows the sum of the operative (or real) time of concentration andthe travel time within the subject run The result represents the time of concentration atthe downstream end of the subject run

Column 21 You can use the remarks column for a variety of functions The following maybe recorded in this column as the design is developedbull documentation and design notesbull additional information andbull clarification

NOTE You may configure the tabular calculation format in several different ways toaccommodate necessary calculations

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 36: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

36of 39

Calculation Explanation for Hydraulic Grade Line

The storm drain system is being designed to accommodate a five-year frequency floodUsing Section 7 of Chapter 10 Hydraulic Grade Line Analysis you must determine anappropriate beginning level at the outfall for development of the hydraulic grade line Thenext subsections deal with the following

diams total watershed

diams suggested downstream frequency

diams hydraulic grade line development calculations

Total Watershed

The total watershed area served by the storm drain system is 918 hectares The watershedfor the outfall channel comprises 9065 hectares The ratio of these areas is about 1001

Suggested Downstream Frequency

With reference to Frequencies for Coincidental Occurrence the suggested downstream(outfall channel) frequency for use in developing the hydraulic grade line is two years Thetwo-year water surface elevation in the outfall channel is 25436 Since the soffit elevationof the node at A10 is 25403 the hydraulic grade line should be developed throughout thesystem for this example

Hydraulic Grade Line Development Calculations

The Hydraulic Grade Line Calculations table shows the suggested tabular format forcalculations in the development of the hydraulic grade line in this example and thissubsection explains the columns

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 37: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

37of 39

Hydraulic Grade Line CalculationsD

S ID

US

ID

Q (m

3 s)

Con

duit

Leng

th (m

)

Nom

inal

Siz

e (m

m)

Fric

tion

Slop

e (

)

Con

duit

Slop

e (

)

Fric

tion

Loss

(m)

DS

HG

L (m

)

DS

HG

L +

Los

s (m

)

Uni

form

Dep

th (m

)

US

FL

Elev

(m

)

US

FL

+ U

nifo

rm D

epth

(m)

US

HG

L (m

)

Rem

arks

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

A10 A9 1749 40 1050 0350 0600 0140 254360 254500 0687 253220 253907 254500 DSHGL outfallelevation

A9 A8 1753 104 1050 0351 0587 0365 254500 254865 0693 253830 254523 254865A8 A7 1370 60 900 0489 0567 0293 254865 255159 0686 254320 255006 255159A7 N1 0143 18 600 0046 0111 0008 255159 255167 0351 254640 254991 255167A7 M1 0115 20 450 0140 0400 0028 255167 255195 0249 254850 255099 255195A7 A6 1194 56 900 0371 0482 0208 255195 255403 0653 254590 255243 255403A6 L3 0277 20 600 0173 0400 0035 255403 255437 0355 254970 255325 255437L3 L2 0241 86 600 0132 0326 0113 255437 255551 0347 255250 255597 255597L2 K1 0127 55 450 0170 0400 0094 255597 255691 0265 255620 255885 255885L2 L1 0070 95 450 0052 0495 0049 255885 255934 0176 255870 256046 256046A6 H2 0240 57 750 0040 0123 0023 256046 256069 0405 254810 255215 256069H2 I1 0097 60 450 0098 0417 0059 256069 256128 0221 255360 255581 256128H2 H1 0039 125 450 0016 0256 0020 256128 256148 0153 255430 255583 25648G1 J1 0180 25 450 0338 0520 0085 256148 256232 0306 255490 255796 256232A6 A5 0862 75 900 0193 0320 0145 256232 256377 0596 254830 255426 256377A5 F1 0031 25 450 0010 0400 0003 256377 256380 0127 255380 255507 256380A5 G1 0302 20 600 0207 0400 0041 256380 256421 0376 255210 255586 256421A5 A4 0591 75 750 0240 0480 0180 256421 256602 0466 255340 255806 256602A4 E2 0156 20 450 0255 0300 0051 256602 256653 0340 255700 256040 256653E2 E1 0045 90 450 0021 0500 0019 256653 256672 0139 256150 256289 256672A4 A3 0445 20 600 0449 0550 0090 256672 256762 0446 255600 256046 256762A3 D1 0049 20 450 0025 0350 0005 256762 256767 0159 255820 255979 256767A3 C1 0176 20 600 0070 0300 0014 256767 256781 0294 255660 255954 256781A3 A2 0247 100 600 0138 0470 0138 256781 256919 0315 256070 256385 256919A2 B1 0039 20 450 0016 0300 0003 256919 256922 0146 256280 256426 256922A2 A1 0191 20 450 0383 0450 0077 256922 256998 0341 256310 256651 256998

Column 1 For convenience the downstream node identification is given first Because thestorm drain system is a dendritic system the one node may serve as the downstreamlocation for multiple runs (except for the outfall)

Column 2 This column contains the upstream node identification

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 38: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

38of 39

Column 3 The discharge listed here is determined in the hydrologic development of theconduit system design

Column 4 The length of the run is listed here and is influential in the hydraulic grade linedevelopment

Column 5 This column repeats the diameter as assigned in the design of the conduitsystem

Column 6 The friction slope Sf for the subject run is calculated according to ManningsEquation and rearranged as Equation 10-43 This value is shown as a percentage butmust be expressed in mm for calculations

Column 7 The conduit slope as described in the design of the conduit system appears hererepeated for mathematical convenience

Column 8 The friction loss in the run is the product of the friction slope (Column 6) andthe run length (Column 4) This loss usually is the most significant

Column 9 This column lists the hydraulic grade line elevation at the downstream nodeThe value shown here for the most downstream run is the level of the water surface inthe outfall channel This is because the water surface in the outfall channel (tailwaterlevel) in this example is greater than the soffit elevation of the downstream node of themost downstream run

Column 10 The sum of the hydraulic grade line elevation at the downstream node of thesubject run and the friction loss is a tentative estimate of the level of the hydraulic gradeline at the upstream node in this tabular analysis

Column 11 The uniform depth of flow is indicated in this column

Column 12 This column indicates the flow line elevation for the upstream node Usuallysoffit elevations are matched when conduit depths change Therefore it is important totake this into account when calculating the flow line elevations throughout a conduitsystem

Column 13 The sum of the upstream flow line elevation of the subject run and the uniformdepth of flow is indicated here

Column 14 This column shows the greater value of either Column 10 or Column 13 If thehydraulic grade line as developed through summing friction losses falls to a lowerlevel of the soffit elevation in the conduit calculations do not necessarily have tocontinue if the conduit system has been designed as a non-pressure flow system andother minor losses are expected to be negligible Refer to Equation 10-47 and theJunction Loss Equation Exit Loss Equation and Manhole Loss Equations subsectionsin Chapter 10 Section 7 for accommodation of minor losses

Column 15 You can use the remarks column for a variety of functions As the design isdeveloped this column may include

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations
Page 39: Examples - Searchonlinemanuals.txdot.gov/txdotmanuals/hyd/hyd_apxf.pdf · 1of 39 Examples Introduction This appendix offers the following examples: ♦ Rational Method example problem

39of 39

bull documentation and design notesbull additional informationbull clarificationbull self-reminders

Check all laterals for possible entrance control head in accordance with Section 4 of Chapter8 The design is not complete until you have checked all nodes to ensure that the hydraulicgrade line does not exceed any inlet throat elevations or manhole covers (critical elevations)

NOTE The tabular calculation format may be configured in several different ways toaccount for necessary calculations For example you may need additional columns forcalculating junction losses We encourage you to devise a tabular calculation systemthat best accounts for personal style

  • Examples
    • Introduction
    • Rational Method Example Problem
    • Step 1
    • Step 2
    • Step 3
    • Step 4
    • Step 5
    • Step 6
    • Step 7
    • Hyetograph Example Developed from NRCS 24-Hour Rainfall Distributions
    • Hyetograph Example Using the Balanced Storm Method
    • Muskingum Method
    • Standard Step Method
    • Storm Drain Design
    • Initial Design Process Components
    • Design Iteration Procedure
    • Step 1
    • Step 2
    • Inlets On-Grade Explanation
    • Calculation Explanation for Curb Opening Inlets in Sags
    • Calculation Explanation for Grate Inlets
    • Conduit Design Explanation
    • Calculation Explanation for Hydraulic Grade Line
    • Total Watershed
    • Suggested Downstream Frequency
    • Hydraulic Grade Line Development Calculations

Recommended