+ All Categories
Home > Documents > EZSTIM* III (ES500)...10 ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETY Only Ezstim* III...

EZSTIM* III (ES500)...10 ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETY Only Ezstim* III...

Date post: 26-Apr-2021
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
20
1 EZSTIM* III (ES500) Peripheral Nerve Stimulator And Nerve Locator
Transcript
Page 1: EZSTIM* III (ES500)...10 ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETY Only Ezstim* III and MiniStim* have it! • Electrosurgery has been described as high-frequency electrical

1

EZSTIM* III (ES500) Peripheral Nerve Stimulator And Nerve Locator

Page 2: EZSTIM* III (ES500)...10 ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETY Only Ezstim* III and MiniStim* have it! • Electrosurgery has been described as high-frequency electrical

2

PERIPHERΔL NERVE STIMULΔTION (PNS)

Peripheral Nerve Block (PNB)Neuromuscular Monitoring (NMM)

ICU OR Block Room/OR

Where and When Is It Used?

Page 3: EZSTIM* III (ES500)...10 ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETY Only Ezstim* III and MiniStim* have it! • Electrosurgery has been described as high-frequency electrical

3

Conditions where NMM is essential…

•   Patients who received large doses of NMBAs

•   Those undergoing prolonged surgical procedures

•   Patients at increased risk of postoperative complications from residual block

…ideally should be monitored using objective means.1

NEUROMUSCULΔR MONITORING (NMM)NMM with a PNS is mandatory whenever neuromuscular blocking drugs are used1

Page 4: EZSTIM* III (ES500)...10 ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETY Only Ezstim* III and MiniStim* have it! • Electrosurgery has been described as high-frequency electrical

4

ULTRΔSOUND: CHΔLLENGES FOR CONSIDERΔTION

•   Ultrasound guidance is limited because it cannot identify the needle-nerve interface in all patients in all locations when performed by all practitioners. Ultrasound guidance is practitioner, patient and equipment dependent.3 Therefore a nerve stimulator may need to be used to supplement.

•   Adult Obesity is a problem in the United States with more than one-third (34.9% or 78.6 million) of U.S. adults being obese.4 This can affect ultrasound effectiveness.

•   In circumstances such as obesity, deeper blocks, aberrant anatomy or trauma, ultrasound imaging can be limited.3

•   Relatively inexperienced clinician and even those with intermediate proficiency with ultrasound-guided RA overestimate their ability.3

Page 5: EZSTIM* III (ES500)...10 ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETY Only Ezstim* III and MiniStim* have it! • Electrosurgery has been described as high-frequency electrical

5

NERVE STIMULΔTION IS STILL RELEVΔNTUse of nerve stimulation along with ultrasound may provide an extra safety benefit.3

Electrical nerve stimulation remains a viable and legitimate primary nerve localization alternative for nerve blocks in which ultrasound imaging is challenging or impossible.3

– Kamen V. Vlassakov, MD Director, Division of Regional and Orthopedic Anesthesia

Brigham and Women’s Hospital

‘‘ ’’

Page 6: EZSTIM* III (ES500)...10 ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETY Only Ezstim* III and MiniStim* have it! • Electrosurgery has been described as high-frequency electrical

6

CHΔRΔCTERISTICS OF THE OPTIMΔL DEVICEHelping you care for your patients

•   Battery-operated •   Variety of stimulation

patterns (e.g., Twitch, TOF, Tetanus, and DBS)

FUNCTIONAL VARIETY

•   Compatibility with electrosurgical equipment •   Alerts when monitoring is compromised •   Limits tetanic stimulation duration •   No cross contamination

SAFETY

•   Identifies the needle-nerve interface in nearly all patient types

•   Output range up to 80 mA for larger patients

ACCURACY

•   One device for both NMM and PNB use •   Simplifies Biomed support/

investment •   Cost-effective

DUAL FUNCTION

•   Intuitive LCD display and controls •   Glove-friendly adjustment dial •   No need to calibrate before use •   Error messaging •   Audible indicators of open circuit •   Mounting bracket

USER-FRIENDLY FEATURES & ACCESSORIES

Page 7: EZSTIM* III (ES500)...10 ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETY Only Ezstim* III and MiniStim* have it! • Electrosurgery has been described as high-frequency electrical

7

ΔVΔNOS STIMULΔTOR HISTORYNearly 40 years of innovation & design firsts

1962 – First commercially available stimulator for anesthesia 1968 – First stimulator with Train of Four NS-2A 1984 – First dual function stimulator 1996 – First EZstim*

2004 – First Stimulator to offer: •   ESI compatibility •   Lead set controlled output •   Audible indication for low output current levels

2016 – Improved design & features

1962 2004 1968 1984 2016

Page 8: EZSTIM* III (ES500)...10 ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETY Only Ezstim* III and MiniStim* have it! • Electrosurgery has been described as high-frequency electrical

8

EZSTIM* II (ES400) VS. EZSTIM* III (ES500)Thoughtful Enhancements

•   Audible open circuit or high resistance indicator

•   Error message indicators to facilitate troubleshooting

•   Protective, silicone edge (no more need for sleeve)

•   Rubber battery compartment seal (IP21 Rated)

IP21 = Protected against solid foreign objects of 12.5 mm diameter and greater. Protected against vertically falling water drops.

EZstim* II (ES400)

EZstim* III (ES500)

Page 9: EZSTIM* III (ES500)...10 ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETY Only Ezstim* III and MiniStim* have it! • Electrosurgery has been described as high-frequency electrical

9

COMPETITIVE LΔNDSCΔPE OF PERIPHERΔL NERVE STIMULΔTORS

*Registered Trademark or Trademark of Avanos Medical, Inc. or its affiliates. All other trademarks are the property of their respective owners.

Page 10: EZSTIM* III (ES500)...10 ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETY Only Ezstim* III and MiniStim* have it! • Electrosurgery has been described as high-frequency electrical

10

ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETYOnly Ezstim* III and MiniStim* have it!

•   Electrosurgery has been described as high-frequency electrical current passed through tissue to create a desired clinical effect.5

•   EZstim* III and MiniStim* MS-IVB unit circuitry are shielded so that current from high frequency surgical equipment (e.g., Bovie) doesn't activate the stimulator.

- Minimize interruptions of patient care or neuromuscular monitoring

•   If the unit was not shielded, it may couple with the high frequency surgical equipment and initiate Tetanus.

-  Potentially causing burns where the leads are connected to the patient.

•   Competitive products must first be turned off/disconnected from the leads during electrosurgery.

- Otherwise they may risk patient safety and incur liability.

Page 11: EZSTIM* III (ES500)...10 ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETY Only Ezstim* III and MiniStim* have it! • Electrosurgery has been described as high-frequency electrical

11

EZSTIM* III SUPPORT

Page 12: EZSTIM* III (ES500)...10 ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETY Only Ezstim* III and MiniStim* have it! • Electrosurgery has been described as high-frequency electrical

12

EZSTIM* III (ES500)Free Replacements with 2-Year Warranty

Package Label: Lot Number

Unit Label (Back): Serial Number

Page 13: EZSTIM* III (ES500)...10 ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETY Only Ezstim* III and MiniStim* have it! • Electrosurgery has been described as high-frequency electrical

13

MULTIDIMENSIONΔL SUPPORT

EXPERT IMPLEMENTATION ASSISTANCE ONGOING TRAINING

ROUND-THE-CLOCK RESPONSIVENESS EXTENSIVE LOCAL SUPPORT

Over 10 years of experience working with leading institutions to develop successful regional anesthesia programs

For anesthesiologists and multidisciplinary teams to stay current with techniques and keep workflow efficient

With clinician-staffed 24/7 hotline for both patients and nurses—provides reassurance while reducing burden on the physician

From coordinated ON-Q* representatives and clinical experts to ensure uninterrupted personalized coverage and continuing success

Page 14: EZSTIM* III (ES500)...10 ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETY Only Ezstim* III and MiniStim* have it! • Electrosurgery has been described as high-frequency electrical

14

THΔNK YOU!

Page 15: EZSTIM* III (ES500)...10 ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETY Only Ezstim* III and MiniStim* have it! • Electrosurgery has been described as high-frequency electrical

15

REFERENCES

1.  Brull, S.J., Kopman, A.F. “Current Status of Neuromuscular Reversal and Monitoring: Challenges and Opportunities.” Anesthesiology. 2017 Jan;126(1):173-190.

2.  McGrath, Conor D., Hunter, Jennifer M. “Monitoring of Neuromuscular Block.” Continuing Education in Anaesthesia, Critical Care & Pain. 2006; Volume 6, No. 1.

3.  Regional Anesthesia Roundtable: Expert Panel Answers 10 Questions. Anesthesiology News. March 2016. 4.  Ogden, Cynthia et al. Prevalence of Childhood and Adult Obesity in the United States, 2011-2012. JAMA.

2014;311(8):806-814. 5.  Masserwah, Nader N, et. al. “Electrosurgery: History, Principles, and Current and Future Uses.” Journal of the American

College of Surgeons. Vol. 202, No. 3, March 2006.

For more information please visit avanospainmanagement.com

1-800-448-3569 1-844-4AVANOS (1-844-428-2667)

*Registered Trademark or Trademark of Avanos Medical, Inc., or its affiliates. © 2018 AVNS. All rights reserved.

Page 16: EZSTIM* III (ES500)...10 ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETY Only Ezstim* III and MiniStim* have it! • Electrosurgery has been described as high-frequency electrical

16

ΔPPENDIX

Page 17: EZSTIM* III (ES500)...10 ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETY Only Ezstim* III and MiniStim* have it! • Electrosurgery has been described as high-frequency electrical

17

EZSTIM*III (ES500) DUΔL-FUNCTION COMPETITION: TRΔDE-OFFSXanant/Arrow® Stimpod NMS450

•   From IFU: “Do not use the STIMPOD in close proximity to equipment that produces strong electromagnetic fields, such as high frequency surgical equipment. The cable leads could act as antennae and dangerous currents could be induced as a result.”

•   Multifunction switch—press until function displays – Default function is Train of Four

•   Press to activate selection

•   Pressure sensitive current adjustment and menu wheel

•   Menu must be set in advance for repeat modes

•   Thumb ring is reusable—potential cross contamination risk

Requires BA-03 Adaptor for use with Avanos Needles

Page 18: EZSTIM* III (ES500)...10 ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETY Only Ezstim* III and MiniStim* have it! • Electrosurgery has been described as high-frequency electrical

18

EZSTIM*III (ES500) SINGLE-FUNCTION COMPETITION: TRΔDE-OFFSB. Braun Stimuplex® HNS 12

•   Single function for PNB only

•   No pause function

•   Facility must purchase 2 different stimulators if need coverage for NMM usage

•   More expensive to maintain

•   Requires additional product knowledge/support

B. Braun Stimuplex® HNS 12

Page 19: EZSTIM* III (ES500)...10 ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETY Only Ezstim* III and MiniStim* have it! • Electrosurgery has been described as high-frequency electrical

19

PACKAGE CONTENTS: •   ES500 Unit

•   IFU

•   NSL-5 (High Current Lead Wire Set)

•   RBW-5U (Low Current Lead Wire Set)

•   9V Battery

ACCESSORIES: •   Mounting Bracket (MB500)

•   Repair Kit (RK500)

•   NSL-5 (High Current Lead Wire Set)

•   RBW-5U (Low Current Lead Wire Set)*

NSL-5V RBW-5U

*RBW-5L/BB also available

EZSTIM* III (ES500)Contents & Accessories

Page 20: EZSTIM* III (ES500)...10 ELECTROSURGERY COMPΔTIBILITY—GREΔTER PΔTIENT SΔFETY Only Ezstim* III and MiniStim* have it! • Electrosurgery has been described as high-frequency electrical

20

EZSTIM* III FUNCTIONΔL OVERVIEWUser Friendly Controls

11. Output Current Control Knob 12. Knob Position Indicator 13. Power Button 14. Pause Button 15. Twitch Selection Button 16. Volume Control 17. Train of Four Button 18. Double Burst Stimulation Button 19. 50 Hz Tetanus Button 10. 100 Hz Tetanus Button

1

2

3 4 5 6

7 8 9 10


Recommended