Page 1: FANNIN houston - Netrality Data Centers · Three (3) diverse POEs (points of entry) Pre-built inner duct system from POEs to MMR ELECTRICAL • Diverse utility feeds from Polk substation

N E T R A L I T Y P R O P E R T I E S

1 3 0 1 F A N N I N

houston

TO LEARN MORE ABOUT NETRALITY, EMAIL [email protected] OR VISIT

W W W. N E T R A L I T Y. C O M

C H I C A G O

717 SOUTH WELLS

H O U S T O N

1301 FANNIN

K A N S A S C I T Y

1102 GRAND

P H I L A D E L P H I A

401 NORTH BROAD

S T. L O U I S

210 N TUCKER | 900 WALNUT

Page 2: FANNIN houston - Netrality Data Centers · Three (3) diverse POEs (points of entry) Pre-built inner duct system from POEs to MMR ELECTRICAL • Diverse utility feeds from Polk substation

1 3 0 1 F A N N I N

FACILITY

OVERVIEW

INFRASTRUCTURE

• Ceiling heights (slab to slab): 18’

• Column spacing: 36’• Floor loading: 150 lbs/sf• Loading dock:

secure multi-bay dock• Freight elevators:

4,500 lbs capacity• Fire suppression:

pre-action, dual interlock• Cable management:

overhead ladder rack• Wind rated up to 200 mph• Outside the

500-year floodplain• 24/7 network operations

center (NOC)• Critical facility

monitoring system

SECURITY + COMPLIANCE

• ANSI/TIA 942-B Certification Rating 3

• 24/7 manned & monitored security

• Entrance and common area video surveillance on all floors

• DVRs: up to 90 days of storage capacity

• Two (2) factor authentication for MMRs

• SSAE-16 SOC I, Type II Audit Compliance

• HIPPA Compliant• PCI Compliant

COLOCATION

• Carrier neutral, building owned and managed Meet Me Room (MMR)

• Three (3) diverse POEs (points of entry)

• Pre-built inner duct system from POEs to MMR

ELECTRICAL

• Diverse utility feeds from Polk substation at 34,500v

• Utility power: 26,000 kW• Backup generator power:

10,000 kW (N+1)• Fuel supply: 65,000 gallons• UPS system: 1,500 kVA (N+1)• DC power

distribution available

1 3 0 1 F A N N I N

SELECT SERVICE

PROVIDERS

COOLING• Cooling tower capacity: 5,000 tons (N+1), backed up by generators• Chilled water capacity: 3,600 tons (N+1), backed up by generators• Closed-loop chilled water distribution system (N+1)• Data room HVAC: CRAH’s (N+1) with cold aisle containment

AMENITIES• Tenant meeting and conference rooms• Shared office environment available• Luby’s Cafeteria• Fitness center with showers• Tech lounge• Secure onsite parking and storage available

• AT&T• AT&T LNS• Centurylink/Level 3• Cogent Communications• Comcast• Consolidated Communications• Crown Castle Fiber• FiberLight• Hurricane Electric• ICTX WaveMedia• Logix/Alpheus

• Megaport• Meriplex Communications• NexGen Networks• PacketFabric• PS Lightwave• Telia Carrier• Verizon• WiLine Networks• Windstream• Zayo Group