of 29
8/22/2019 FB103 Presentation
1/29
Flow Computer DivisionFB1031 of 29
11-02-04
ESC to Exit
FloBossTM
103Flow Manager
The Cost-Effective Alternative
to Chart Recorders.
8/22/2019 FB103 Presentation
2/29
Flow Computer Division FB1032 of 2911-02-04
ESC to Exit
Say Goodbye to Chart Reco rders...
Manually gathering and
integrating charts is timeconsuming, labor intensive, and
costly.
Low accuracy, off-chart
readings, inking problems, andmalfunctions mean more lost
and unaccounted gas.
Chart recorders provide few
capabilities beyond pressureand temperature measurement.
8/22/2019 FB103 Presentation
3/29
Flow Computer Division FB1033 of 2911-02-04
ESC to Exit
And to Comp licated EFM Instal lat ions...
Typical EFM installations
are a maze of solar panels,battery boxes, radios,
antennas, and wiring
making installation difficult
and costly.
Engineering these
installations can be time
consuming, and the end
result may not meet
performance expectations.
8/22/2019 FB103 Presentation
4/29
Flow Computer Division FB1034 of 2911-02-04
ESC to Exit
And Hel lo to the FloBoss 103
The FloBoss 103 provides fast,
convenient, and inexpensiveelectronic retrieval of gas flow
data locally or remotely.
The FloBoss 103 delivers higher
accuracy and eliminates chartproblems. The result, less lost
and unaccounted gas.
The FloBoss 103 integrates
batteries, communication cards,and sensor into a single, easy-
to-install unit.
8/22/2019 FB103 Presentation
5/29
Flow Computer Division FB1035 of 2911-02-04
ESC to Exit
The FloBoss 103 Miss ion
To fulfill the need for a high-performance,
compact single-run flow computer that is theideal replacement for the traditional paper chart
recorders used in natural gas flow
measurement.
To provide API Chapter 21.1 compliant flowmeasurement in a unit that is self contained --
i.e., batteries and communications are built-in.
All you need to add is an RTD and a 2- or 5-
Watt solar panel for full functionality.
8/22/2019 FB103 Presentation
6/29
Flow Computer Division FB1036 of 2911-02-04
ESC to Exit
Func t ional Overview
The FloBoss 103 provides these outstandingfunctional features:
AGA Flow Calculations
Historical Databases
Event and Alarm Logs
Data Security
Embedded Communications
Spontaneous Report-by-Exception (SRBX)Host Communication
Pass-Through Communication
Closed-loop PID Control Logic and Sequencing Control
ROCLINK 800Configuration Interface
8/22/2019 FB103 Presentation
7/29
Flow Computer Division FB1037 of 2911-02-04
ESC to Exit
AGA Flow Calculat ions
Gas flow is calculated for
both volume and energy inaccordance with the 1992
AGA Report No. 3.
AGA 8 compressibility
calculations use Detail,Gross I, or Gross II
methods.
Meter setup is made quick
and easy using fill-in-the-blanks data entry.
8/22/2019 FB103 Presentation
8/29
Flow Computer Division FB1038 of 2911-02-04
ESC to Exit
Histo rical Databases
The FloBoss 103 maintainsAPI Chapter 21.1 complianthistorical archives formeasured and calculatedvalues, and events/alarms.
Up to 35 standard historypoints can be archived on anhourly and daily basis for upto 35 days.
An extended history databasesupports data logging atintervals from 1 to 60minutes, giving operators theflexibility to meet the needs ofadvanced applications.
8/22/2019 FB103 Presentation
9/29
Flow Computer Division FB1039 of 2911-02-04
ESC to Exit
Event and A larm Logs
The Event Log records
the last 240 parameterchanges and power
on/off cycles.
The Alarm Log records
the last 240 occurrences
of alarms (set or clear).
The logs can be viewed,
saved to a disk file, or
printed by using
ROCLINK 800software.
8/22/2019 FB103 Presentation
10/29
Flow Computer Division FB10310 of 2911-02-04
ESC to Exit
Data Secu rity
A maximum of 16 log-onidentifiers (IDs) for operators
can be stored. The log-on ID entered into
ROCLINK 800must match oneof the stored IDs for the unit tocommunicate.
Both the operator interface andhost can have the samesecurity. Security levels maybe determined by user andaccess level.
8/22/2019 FB103 Presentation
11/29
Flow Computer Division FB10311 of 2911-02-04
ESC to Exit
Embedded Communicat ions
The FloBoss 103 offers abuilt-in EIA-485 port and anoptional EIA-232 port or dial-up modem port for hostcommunications.
An optional spread-spectrum
radio interface supports eitherFreeWave M-Series orMaxStream 9X Streamspread-spectrum radios thatfit entirely within the FloBoss
103 enclosure.
8/22/2019 FB103 Presentation
12/29
Flow Computer Division FB10312 of 2911-02-04
ESC to Exit
SRBX Commun icat ion
Spontaneous Report-By
-Exception (SRBX)communication allows
the FloBoss 103 to
automatically report any
alarm to a host
computer.
SRBX can be performed
over dial-up modem or
serial line to a host that
is set up for receiving
field-initiated calls.
8/22/2019 FB103 Presentation
13/29
Flow Computer Division FB10313 of 2911-02-04
ESC to Exit
Pass-Through Commun icat ions
Pass-through gives the
FloBoss 103 the capability topass information between a
host and devices connected
to the FloBoss 103 that use
ROC or Modbus protocol.
Pass-through reduces the
cost of communication when
several devices are
geographically grouped.
Pass-through is available foruse with RS485, RS232, or
dial-up modem connections.
8/22/2019 FB103 Presentation
14/29
Flow Computer Division FB10314 of 2911-02-04
ESC to Exit
PID Loop Contro l
PID (Proportional,
Integral, and Derivative)closed-loop control
provides stable
operation of a feedback
control loop that
employs a regulating
device, such as a control
valve.
The PID loop has its
own user-defined input,
output, and override
capability.
8/22/2019 FB103 Presentation
15/29
Flow Computer Division FB10315 of 2911-02-04
ESC to Exit
Logic and Sequencing Contro l
Analog and discrete
sequencing control isimplemented through a
Function Sequence
Table (FST).
The FST defines the
actions to be performed
by the FloBoss 103
through a series of
Functions.
The FST is developedusing ROCLINK 800
software.
8/22/2019 FB103 Presentation
16/29
Flow Computer Division FB10316 of 2911-02-04
ESC to Exit
ROCLINK 800 Con figu rat ion In terface
ROCLINK 800is the easy-
to-use software forconfiguration and
downloading data.
Compatible with most other
FloBoss and ROC productsfor convenience in mixed-
product installations.
On-line Help screens get
first-time users up andrunning quickly.
8/22/2019 FB103 Presentation
17/29
Flow Computer Division FB10317 of 2911-02-04
ESC to Exit
FloBoss 103 Techn ical Features
High-Accuracy Dual-Variable Sensor
32-bit Processor
Built-in Battery Pack
Communications Cards / Radio
Termination / I/O Board
Rugged CSA-Approved Design
Local Operator Display
Solar Panel and Mast
8/22/2019 FB103 Presentation
18/29
Flow Computer Division FB10318 of 2911-02-04
ESC to Exit
FloBoss 103 Component Overview
Processor
MemoryBackup
LCD
Battery Pack
& Charger
Modem / RS232 Backplane Dual-Variable Sensor
Termination
Board
8/22/2019 FB103 Presentation
19/29
Flow Computer Division FB10319 of 2911-02-04
ESC to Exit
High -Accuracy Dual-Variab le Senso r
Dual-variable sensor uses
Rosemount capacitancecell technology.
Measures static and
differential pressure.
Accuracy is +0.1%standard or +0.075%
optional.
High stability design means
less calibration. Exclusive co-planer flange
for easy installation.
8/22/2019 FB103 Presentation
20/29
Flow Computer Division FB10320 of 2911-02-04
ESC to Exit
32-B it Processor / Backplane
High performance 32-bit
processor is designed forlow-power applications.
Memory consists of:
128 Kb flash boot ROM
2 Mb flash program ROM
512 Kb of data RAM
All boards plug into a
backplane making removal
and replacement quick andeasy.
Processor
Backplane
8/22/2019 FB103 Presentation
21/29
Flow Computer Division FB10321 of 2911-02-04
ESC to Exit
Bu il t -In Battery Pack
Rechargeable lead acid
batteries provide more than15 days of autonomy, at
one modem poll per day,
without recharging.
A 2- or 5-Watt solar panelwill operate the FloBoss
103 indefinitely in a typical
installation.
Real-time clock and staticRAM are backed up with a
3.6v lithium battery.
8/22/2019 FB103 Presentation
22/29
Flow Computer Division FB10322 of 2911-02-04
ESC to Exit
Commun icat ions Cards / Radio
Local Operator Interface port
uses RS-232C format. Standard RS-485 port is
configurable for 600 to
19.2 K baud.
Communication to a Host issupported by an optional RS-
232 or modem card, or built-in
spread spectrum radio.
Available protocols include ROCor Modbus Slave (ASCII or
RTU).
8/22/2019 FB103 Presentation
23/29
Flow Computer Division FB10323 of 2911-02-04
ESC to Exit
Term ination / I/O Board
2 or 3-wire RTD element input
is built-in. Diagnostic inputs for internal
voltage, battery voltage, and
enclosure/battery temperature
are built-in. Optional I/O board provides 6
channels of I/O that are switch-
selectable in combinations of
analog and discrete inputs andoutputs, and pulse inputs.
8/22/2019 FB103 Presentation
24/29
Flow Computer Division FB10324 of 2911-02-04
ESC to Exit
Rugged, CSA-App roved Design
The base FloBoss 103 is approvedfor use in Class I, Division 1 andDivision 2 areas.
The Solar Panel and Mast Assemblyare approved for use in Class I,Division 2 areas only.
Housing and end caps are die-castaluminum alloy with iridite plating
and paint.
Field wiring routes through side-
mounted conduit ports and connectsto the termination board located
behind a removeable endcap.
8/22/2019 FB103 Presentation
25/29
Flow Computer Division FB10325 of 2911-02-04
ESC to Exit
Local Operato r Disp lay (Optional)
Flow information is scrolled
on a two-line liquid crystaldisplay (LCD) when
activated by the user.
Top line displays values
(8 numerals) and bottomline displays descriptions
(5 alpha-numeric
characters).
Information displayed isconfigured by the user
according to their needs.
8/22/2019 FB103 Presentation
26/29
Flow Computer Division FB10326 of 2911-02-04ESC to Exit
Solar Panel and Mast (Optional)
Optional solar panel andmast attach to the top ofthe FloBoss 103.
Solar panel can bepositioned 360 degrees inazimuth and 90 degrees in
elevation for optimal suncoverage.
The 2-Watt panelmeasures only 4 by 6.25inches and the 5-Watt only8.75 by 9 inches.
8/22/2019 FB103 Presentation
27/29
Flow Computer Division FB10327 of 2911-02-04ESC to Exit
Go With the Leader in Process Con tro l ...
Appliance
Solutions
Motor
Technologies
Professional
ToolsStorage
Solutions
Industrial
Automation
Climate
Technologies
Network
Power
Process
Management
Emerson Power &
Water Solutions
8/22/2019 FB103 Presentation
28/29
Flow Computer Division FB10328 of 2911-02-04ESC to Exit
...And the Leader in Products and Service
Rated Very Good orbetter in 33 Service
Categories
More than twice ourclosest competitor
#1IN SERVICES
1s t/2nd/3rdPLACEFINISHES
Emerson 39Rockwell 17Honeywell 16Invensys 14Siemens 15ABB 5
Emerson ProcessManagement offers theindustry's broadest array ofprocess-automationproducts.
So it's not surprising that,
in an independent surveyconducted by Controlmagazine, users have onceagain ranked our productsfirst in more categories
than any other supplier.
http://www.emersonprocess.com/home/products/rchoice2004.htmlhttp://www.emersonprocess.com/home/products/rchoice2004.htmlhttp://www.emersonprocess.com/home/products/rchoice2004.htmlhttp://www.emersonprocess.com/home/products/rchoice2004.html8/22/2019 FB103 Presentation
29/29
Flow Computer Division FB10329 of 29
ESC to Exit
Go w ith Emerson Process Management!
For detailed information on the
FloBoss 103 and other great FlowComputer Division products, contact
your Emerson Process Management
Representative or call:
1-800-807-0730(U.S. & Canada only)
1-641-754-3449 (Worldwide)
You can also visit us on the World
Wide Web at:
www.EmersonProcess.com/flow