    Flow Computer DivisionFB1031 of 29

    11-02-04

    ESC to Exit

    FloBossTM

    103Flow Manager

    The Cost-Effective Alternative

    to Chart Recorders.

  • 8/22/2019 FB103 Presentation

    2/29

    Flow Computer Division FB1032 of 2911-02-04

    ESC to Exit

    Say Goodbye to Chart Reco rders...

    Manually gathering and

    integrating charts is timeconsuming, labor intensive, and

    costly.

    Low accuracy, off-chart

    readings, inking problems, andmalfunctions mean more lost

    and unaccounted gas.

    Chart recorders provide few

    capabilities beyond pressureand temperature measurement.

  • 8/22/2019 FB103 Presentation

    3/29

    Flow Computer Division FB1033 of 2911-02-04

    ESC to Exit

    And to Comp licated EFM Instal lat ions...

    Typical EFM installations

    are a maze of solar panels,battery boxes, radios,

    antennas, and wiring

    making installation difficult

    and costly.

    Engineering these

    installations can be time

    consuming, and the end

    result may not meet

    performance expectations.

  • 8/22/2019 FB103 Presentation

    4/29

    Flow Computer Division FB1034 of 2911-02-04

    ESC to Exit

    And Hel lo to the FloBoss 103

    The FloBoss 103 provides fast,

    convenient, and inexpensiveelectronic retrieval of gas flow

    data locally or remotely.

    The FloBoss 103 delivers higher

    accuracy and eliminates chartproblems. The result, less lost

    and unaccounted gas.

    The FloBoss 103 integrates

    batteries, communication cards,and sensor into a single, easy-

    to-install unit.

  • 8/22/2019 FB103 Presentation

    5/29

    Flow Computer Division FB1035 of 2911-02-04

    ESC to Exit

    The FloBoss 103 Miss ion

    To fulfill the need for a high-performance,

    compact single-run flow computer that is theideal replacement for the traditional paper chart

    recorders used in natural gas flow

    measurement.

    To provide API Chapter 21.1 compliant flowmeasurement in a unit that is self contained --

    i.e., batteries and communications are built-in.

    All you need to add is an RTD and a 2- or 5-

    Watt solar panel for full functionality.

  • 8/22/2019 FB103 Presentation

    6/29

    Flow Computer Division FB1036 of 2911-02-04

    ESC to Exit

    Func t ional Overview

    The FloBoss 103 provides these outstandingfunctional features:

    AGA Flow Calculations

    Historical Databases

    Event and Alarm Logs

    Data Security

    Embedded Communications

    Spontaneous Report-by-Exception (SRBX)Host Communication

    Pass-Through Communication

    Closed-loop PID Control Logic and Sequencing Control

    ROCLINK 800Configuration Interface

  • 8/22/2019 FB103 Presentation

    7/29

    Flow Computer Division FB1037 of 2911-02-04

    ESC to Exit

    AGA Flow Calculat ions

    Gas flow is calculated for

    both volume and energy inaccordance with the 1992

    AGA Report No. 3.

    AGA 8 compressibility

    calculations use Detail,Gross I, or Gross II

    methods.

    Meter setup is made quick

    and easy using fill-in-the-blanks data entry.

  • 8/22/2019 FB103 Presentation

    8/29

    Flow Computer Division FB1038 of 2911-02-04

    ESC to Exit

    Histo rical Databases

    The FloBoss 103 maintainsAPI Chapter 21.1 complianthistorical archives formeasured and calculatedvalues, and events/alarms.

    Up to 35 standard historypoints can be archived on anhourly and daily basis for upto 35 days.

    An extended history databasesupports data logging atintervals from 1 to 60minutes, giving operators theflexibility to meet the needs ofadvanced applications.

  • 8/22/2019 FB103 Presentation

    9/29

    Flow Computer Division FB1039 of 2911-02-04

    ESC to Exit

    Event and A larm Logs

    The Event Log records

    the last 240 parameterchanges and power

    on/off cycles.

    The Alarm Log records

    the last 240 occurrences

    of alarms (set or clear).

    The logs can be viewed,

    saved to a disk file, or

    printed by using

    ROCLINK 800software.

  • 8/22/2019 FB103 Presentation

    10/29

    Flow Computer Division FB10310 of 2911-02-04

    ESC to Exit

    Data Secu rity

    A maximum of 16 log-onidentifiers (IDs) for operators

    can be stored. The log-on ID entered into

    ROCLINK 800must match oneof the stored IDs for the unit tocommunicate.

    Both the operator interface andhost can have the samesecurity. Security levels maybe determined by user andaccess level.

  • 8/22/2019 FB103 Presentation

    11/29

    Flow Computer Division FB10311 of 2911-02-04

    ESC to Exit

    Embedded Communicat ions

    The FloBoss 103 offers abuilt-in EIA-485 port and anoptional EIA-232 port or dial-up modem port for hostcommunications.

    An optional spread-spectrum

    radio interface supports eitherFreeWave M-Series orMaxStream 9X Streamspread-spectrum radios thatfit entirely within the FloBoss

    103 enclosure.

  • 8/22/2019 FB103 Presentation

    12/29

    Flow Computer Division FB10312 of 2911-02-04

    ESC to Exit

    SRBX Commun icat ion

    Spontaneous Report-By

    -Exception (SRBX)communication allows

    the FloBoss 103 to

    automatically report any

    alarm to a host

    computer.

    SRBX can be performed

    over dial-up modem or

    serial line to a host that

    is set up for receiving

    field-initiated calls.

  • 8/22/2019 FB103 Presentation

    13/29

    Flow Computer Division FB10313 of 2911-02-04

    ESC to Exit

    Pass-Through Commun icat ions

    Pass-through gives the

    FloBoss 103 the capability topass information between a

    host and devices connected

    to the FloBoss 103 that use

    ROC or Modbus protocol.

    Pass-through reduces the

    cost of communication when

    several devices are

    geographically grouped.

    Pass-through is available foruse with RS485, RS232, or

    dial-up modem connections.

  • 8/22/2019 FB103 Presentation

    14/29

    Flow Computer Division FB10314 of 2911-02-04

    ESC to Exit

    PID Loop Contro l

    PID (Proportional,

    Integral, and Derivative)closed-loop control

    provides stable

    operation of a feedback

    control loop that

    employs a regulating

    device, such as a control

    valve.

    The PID loop has its

    own user-defined input,

    output, and override

    capability.

  • 8/22/2019 FB103 Presentation

    15/29

    Flow Computer Division FB10315 of 2911-02-04

    ESC to Exit

    Logic and Sequencing Contro l

    Analog and discrete

    sequencing control isimplemented through a

    Function Sequence

    Table (FST).

    The FST defines the

    actions to be performed

    by the FloBoss 103

    through a series of

    Functions.

    The FST is developedusing ROCLINK 800

    software.

  • 8/22/2019 FB103 Presentation

    16/29

    Flow Computer Division FB10316 of 2911-02-04

    ESC to Exit

    ROCLINK 800 Con figu rat ion In terface

    ROCLINK 800is the easy-

    to-use software forconfiguration and

    downloading data.

    Compatible with most other

    FloBoss and ROC productsfor convenience in mixed-

    product installations.

    On-line Help screens get

    first-time users up andrunning quickly.

  • 8/22/2019 FB103 Presentation

    17/29

    Flow Computer Division FB10317 of 2911-02-04

    ESC to Exit

    FloBoss 103 Techn ical Features

    High-Accuracy Dual-Variable Sensor

    32-bit Processor

    Built-in Battery Pack

    Communications Cards / Radio

    Termination / I/O Board

    Rugged CSA-Approved Design

    Local Operator Display

    Solar Panel and Mast

  • 8/22/2019 FB103 Presentation

    18/29

    Flow Computer Division FB10318 of 2911-02-04

    ESC to Exit

    FloBoss 103 Component Overview

    Processor

    MemoryBackup

    LCD

    Battery Pack

    & Charger

    Modem / RS232 Backplane Dual-Variable Sensor

    Termination

    Board

  • 8/22/2019 FB103 Presentation

    19/29

    Flow Computer Division FB10319 of 2911-02-04

    ESC to Exit

    High -Accuracy Dual-Variab le Senso r

    Dual-variable sensor uses

    Rosemount capacitancecell technology.

    Measures static and

    differential pressure.

    Accuracy is +0.1%standard or +0.075%

    optional.

    High stability design means

    less calibration. Exclusive co-planer flange

    for easy installation.

  • 8/22/2019 FB103 Presentation

    20/29

    Flow Computer Division FB10320 of 2911-02-04

    ESC to Exit

    32-B it Processor / Backplane

    High performance 32-bit

    processor is designed forlow-power applications.

    Memory consists of:

    128 Kb flash boot ROM

    2 Mb flash program ROM

    512 Kb of data RAM

    All boards plug into a

    backplane making removal

    and replacement quick andeasy.

    Processor

    Backplane

  • 8/22/2019 FB103 Presentation

    21/29

    Flow Computer Division FB10321 of 2911-02-04

    ESC to Exit

    Bu il t -In Battery Pack

    Rechargeable lead acid

    batteries provide more than15 days of autonomy, at

    one modem poll per day,

    without recharging.

    A 2- or 5-Watt solar panelwill operate the FloBoss

    103 indefinitely in a typical

    installation.

    Real-time clock and staticRAM are backed up with a

    3.6v lithium battery.

  • 8/22/2019 FB103 Presentation

    22/29

    Flow Computer Division FB10322 of 2911-02-04

    ESC to Exit

    Commun icat ions Cards / Radio

    Local Operator Interface port

    uses RS-232C format. Standard RS-485 port is

    configurable for 600 to

    19.2 K baud.

    Communication to a Host issupported by an optional RS-

    232 or modem card, or built-in

    spread spectrum radio.

    Available protocols include ROCor Modbus Slave (ASCII or

    RTU).

  • 8/22/2019 FB103 Presentation

    23/29

    Flow Computer Division FB10323 of 2911-02-04

    ESC to Exit

    Term ination / I/O Board

    2 or 3-wire RTD element input

    is built-in. Diagnostic inputs for internal

    voltage, battery voltage, and

    enclosure/battery temperature

    are built-in. Optional I/O board provides 6

    channels of I/O that are switch-

    selectable in combinations of

    analog and discrete inputs andoutputs, and pulse inputs.

  • 8/22/2019 FB103 Presentation

    24/29

    Flow Computer Division FB10324 of 2911-02-04

    ESC to Exit

    Rugged, CSA-App roved Design

    The base FloBoss 103 is approvedfor use in Class I, Division 1 andDivision 2 areas.

    The Solar Panel and Mast Assemblyare approved for use in Class I,Division 2 areas only.

    Housing and end caps are die-castaluminum alloy with iridite plating

    and paint.

    Field wiring routes through side-

    mounted conduit ports and connectsto the termination board located

    behind a removeable endcap.

  • 8/22/2019 FB103 Presentation

    25/29

    Flow Computer Division FB10325 of 2911-02-04

    ESC to Exit

    Local Operato r Disp lay (Optional)

    Flow information is scrolled

    on a two-line liquid crystaldisplay (LCD) when

    activated by the user.

    Top line displays values

    (8 numerals) and bottomline displays descriptions

    (5 alpha-numeric

    characters).

    Information displayed isconfigured by the user

    according to their needs.

  • 8/22/2019 FB103 Presentation

    26/29

    Flow Computer Division FB10326 of 2911-02-04ESC to Exit

    Solar Panel and Mast (Optional)

    Optional solar panel andmast attach to the top ofthe FloBoss 103.

    Solar panel can bepositioned 360 degrees inazimuth and 90 degrees in

    elevation for optimal suncoverage.

    The 2-Watt panelmeasures only 4 by 6.25inches and the 5-Watt only8.75 by 9 inches.

  • 8/22/2019 FB103 Presentation

    27/29

    Flow Computer Division FB10327 of 2911-02-04ESC to Exit

    Go With the Leader in Process Con tro l ...

    Appliance

    Solutions

    Motor

    Technologies

    Professional

    ToolsStorage

    Solutions

    Industrial

    Automation

    Climate

    Technologies

    Network

    Power

    Process

    Management

    Emerson Power &

    Water Solutions

  • 8/22/2019 FB103 Presentation

    28/29

    Flow Computer Division FB10328 of 2911-02-04ESC to Exit

    ...And the Leader in Products and Service

    Rated Very Good orbetter in 33 Service

    Categories

    More than twice ourclosest competitor

    #1IN SERVICES

    1s t/2nd/3rdPLACEFINISHES

    Emerson 39Rockwell 17Honeywell 16Invensys 14Siemens 15ABB 5

    Emerson ProcessManagement offers theindustry's broadest array ofprocess-automationproducts.

    So it's not surprising that,

    in an independent surveyconducted by Controlmagazine, users have onceagain ranked our productsfirst in more categories

    than any other supplier.

    http://www.emersonprocess.com/home/products/rchoice2004.htmlhttp://www.emersonprocess.com/home/products/rchoice2004.htmlhttp://www.emersonprocess.com/home/products/rchoice2004.htmlhttp://www.emersonprocess.com/home/products/rchoice2004.html
  • 8/22/2019 FB103 Presentation

    29/29

    Flow Computer Division FB10329 of 29

    ESC to Exit

    Go w ith Emerson Process Management!

    For detailed information on the

    FloBoss 103 and other great FlowComputer Division products, contact

    your Emerson Process Management

    Representative or call:

    1-800-807-0730(U.S. & Canada only)

    1-641-754-3449 (Worldwide)

    You can also visit us on the World

    Wide Web at:

    www.EmersonProcess.com/flow


Recommended