P: 540.659.2132 F: 540.659.2133 [email protected] 2040 Jefferson Davis Highway, Stafford, Virginia 22554 www.MetropoleProducts.com FBF-309-L DESCRIPTION FEATURES Low insertion loss and good VSWR are achieved in this high Q, EMP protected bandpass filter. The model FBF-309-L features an EMP protection clamp voltage of 150V. } Bandpass Filter } EMP Protected
Transcript
Page 1: FBF-309-L - Metropole Products...FBF-309-L DESCRIPTION FEATURES Low insertion loss and good VSWR are achieved in this high Q, EMP protected bandpass filter. The model FBF-309-L features

P: 540.659.2132 F: 540.659.2133

[email protected]

2040 Jefferson Davis Highway, Stafford, Virginia 22554

www.MetropoleProducts.com

FBF-309-L

DESCRIPTION FEATURESLow insertion loss and good VSWR are achieved in this high Q, EMP protected bandpass filter. The model FBF-309-L features an EMP protection clamp voltage of 150V.

} Bandpass Filter

} EMP Protected

FBF-309-L

MPI Metropole Products, Inc.2040 Jefferson Davis Hwy. • Stafford,Virginia 22554 • 540.659.2132fx. 540.659.2133 • e. [email protected] www.MetropoleProducts.com

Description

Low insertion loss and good VSWR are achieved in this high Q, EMP protected bandpass � lter. The model FBF-309-L features an EMP protection clamp voltage of 150 V.

Features

• Bandpass Filter • EMP Protected

Page 2: FBF-309-L - Metropole Products...FBF-309-L DESCRIPTION FEATURES Low insertion loss and good VSWR are achieved in this high Q, EMP protected bandpass filter. The model FBF-309-L features

P: 540.659.2132 F: 540.659.2133

[email protected]

2040 Jefferson Davis Highway, Stafford, Virginia 22554

www.MetropoleProducts.com

FBF-309-L

SPECIFICATIONS

Center Frequency, nominal ............................................................................................................................................................................... 167 MHz

1 dB Bandwidth, Note 1 ............................................................................................................................................................................... 16 MHz min.

40 dB Bandwidth ........................................................................................................................................................................................ 45 MHz max.

Insertion Loss ................................................................................................................................................................................................1.5 dB max.

VSWR over 160 to 174 Mhz ......................................................................................................................................................1.6:1 max., 1.5:1 at center

Impedance ....................................................................................................................................................................................................50Ω nominal

Connectors ................................................................................................................................................................................................... TNC Female

Weight ..................................................................................................................................................................................................................... 15 oz.

Clamp Voltage Protection ........................................................................................................................................................................... 150V nominal

Note 1: Bandwidth is measured from the minimum insertion loss value. The lower 1 dB frequency must be ≤ 159 MHz, the upper 1 dB frequency must be ≥ 175 MHz

FBF-309-L

MPI Metropole Products, Inc.2040 Jefferson Davis Hwy. • Stafford,Virginia 22554 • 540.659.2132fx. 540.659.2133 • e. [email protected]

Speci� cations

Center Frequency, nominal .................................................................................................................................................................................................................................. 167 MHz1 dB Bandwidth, Note 1 ..............................................................................................................................................................................................................................16 MHz min.40 dB Bandwidth .......................................................................................................................................................................................................................................... 45 MHz max.Insertion Loss ...................................................................................................................................................................................................................................................1.5 dB max.VSWR over 160 to 174 Mhz ....................................................................................................................................................................................................1.6:1 max., 1.5:1 at center.Impedance .....................................................................................................................................................................................................................................................50Ω nominalConnectors .......................................................................................................................................................................................................................................................TNC FemaleWeight ....................................................................................................................................................................................................................................................................... 15 oz.Clamp Voltage Protection ........................................................................................................................................................................................................................... 150 V nominal

Note 1: Bandwidth is measured from the minimum insertion loss value. The lower 1 dB frequency must be ≤ 159 MHz, the upper 1 dB frequency must be ≥ 175 MHz