+ All Categories
Home > Documents > FD Frame - tekhar.comtekhar.com/Programma/GE/pdf_pict/FD.pdf · A A.5 FD frame 3 pole 3 trips 4...

FD Frame - tekhar.comtekhar.com/Programma/GE/pdf_pict/FD.pdf · A A.5 FD frame 3 pole 3 trips 4...

Date post: 13-Aug-2019
Category:
Upload: trannhi
View: 230 times
Download: 1 times
Share this document with a friend
7
A GE Power Controls A.4 How to order FD Frame Breaking capacities 2, 3 and 4 pole types Single pole types Protection Accessories Type FD63 FD160 S 36 36 E 25 25 C 18 18 N 50 50 N 25 H 80 80 H 50 L 150 150 Icu 400/415V AC in kA eff. Icu 230/240V AC in kA eff. Trip Unit FD63 (2,3 & 4 pole) FD160 (2,3 & 4 pole) Trip Unit FD160 (single pole) Rated Current (A) 3 7 12.5 16 20 25 30 32 40 50 63 80 100 125 160 Rated Current (A) 16 20 25 32 40 50 63 80 100 125 160 LTM C,E C,E C,E C,E C,E C,E C,E C,E C,E C,E C,E LTM N,H N,H N,H N,H N,H N,H N,H N,H N,H N,H N,H LTMD S,N,H S,N,H S,N,H,L S,N,H,L S,N,H,L S,N,H,L S,N,H,L S,N,H,L S,N,H,L S,N,H,L S,N,H,L GTM N,H N,H N,H N,H N,H N,H N,H N,H N,H Mag Break TM N,H N,H N,H N,H,L N,H,L N,H,L N,H,L N,H,L Number of poles/ protected poles (trips) 2 pole 2 trips 3 pole 3 trips 4 pole 3 trips 4 pole 4 trips 4 pole 3.5 trips (N=50%) (2) Number of poles/ protected poles (trips) 1 pole 1 trip C,E C,E N,H N S,N,H,L N,H,L S,N,H,L N,H,L N,H N,H N,H N,H N,H,L N,H,L Auxiliary contact left mounted (NO or NC) Auxiliary contact right mounted (NO or NC) Bell Alarm trip unit (NO or NC) Bell Alarm mechanism (CO) (1) Shunt or Undervoltage release Operators Rotary Handle Electrical Operator RCD, side or bottom mounted (Insert indicates Bell alarm contact mounting) Plug in system (1) (1) Not applicable for the FDC types. (2) Rated current 63A LTM Line thermal magnetic protection LTMD Selective thermal magnetic protection GTM Generator thermal magnetic protection Mag Break TM Magnetic Only protection Y Non Automatic or switch (not mentioned in tables) O 1 O 2 O 3 O 4 O 5 O 6 O 7 O 8
Transcript

A

GE Power ControlsA.4

How

to

orde

r

FD Frame

Breaking capacities

2, 3 and 4 pole types Single pole types

Protection

Accessories

TypeFD63FD160

S3636

E 2525

C 1818

N5050

N

25

H8080

H

50

L150150

Icu 400/415V AC in kA eff.

Icu 230/240V AC in kA eff.

TripUnit

FD63(2,3 &

4 pole)

FD160(2,3 &

4 pole)

TripUnit

FD160(singlepole)

RatedCurrent

(A)

37

12.5162025303240506380100125160

RatedCurrent

(A)

162025

3240506380100125160

LTM

C,EC,EC,E

C,EC,EC,EC,EC,EC,EC,EC,E

LTM

N,HN,HN,H

N,HN,HN,HN,HN,HN,HN,HN,H

LTMD

S,N,HS,N,H

S,N,H,L

S,N,H,LS,N,H,LS,N,H,LS,N,H,LS,N,H,LS,N,H,LS,N,H,LS,N,H,L

GTM

N,H

N,HN,HN,HN,HN,HN,HN,HN,H

MagBreakTM

N,H N,H N,H

N,H,L

N,H,L

N,H,L

N,H,LN,H,L

Number of poles/protected poles

(trips)

2 pole 2 trips3 pole 3 trips4 pole 3 trips4 pole 4 trips

4 pole 3.5 trips(N=50%)(2)

Number of poles/protected poles

(trips)

1 pole 1 tripC,E

C,E

N,HNS,N,H,LN,H,L

S,N,H,L

N,H,L

N,HN,HN,H

N,H

N,H,LN,H,L

Auxiliary contact left mounted

(NO or NC)

Auxiliary contact right mounted

(NO or NC)

Bell Alarm trip unit (NO or NC)

Bell Alarm mechanism (CO)(1)

Shunt or Undervoltage release

Operators

Rotary Handle

Electrical Operator

RCD, side or bottom mounted

(Insert indicates Bell alarm contact

mounting)

Plug in system(1)

(1) Not applicable for the FDC types.(2) Rated current ≥ 63A

LTMLine thermal magnetic protectionLTMDSelective thermal magneticprotectionGTMGenerator thermal magneticprotectionMag BreakTM

Magnetic Only protectionYNon Automatic or switch (not mentioned in tables)

O1

O2

O3O4O5O6

O7

O8

A

A.5

FD frame

4 pole 4 trips(1)3 pole 3 tripsRef. nr.

Cat. nr.

FDC45TC016EFFDC45TC020EFFDC45TC025EFFDC45TC032EFFDC45TC040EFFDC45TC050EFFDC45TC063EFFDC45TC080GFFDC45TC100GFFDC45TC125GFFDC45TC160GF

FDC45TE016EDFDC45TE020EDFDC45TE025EDFDC45TE032EDFDC45TE040EDFDC45TE050EDFDC45TE063EDFDC45TE080GDFDC45TE100GDFDC45TE125GDFDC45TE160GD

FDE46TF016EFFDE46TF020EFFDE46TF025EFFDE46TF032EFFDE46TF040EFFDE46TF050EFFDE46TF063EFFDE46TF080GFFDE46TF100GFFDE45TF125GFFDE45TF160GF

FDE45TC016EFFDE45TC020EFFDE45TC025EFFDE45TC032EFFDE45TC040EFFDE45TC050EFFDE45TC063EFFDE45TC080GFFDE45TC100GFFDE45TC125GFFDE45TC160GF

FDE45TE016EDFDE45TE020EDFDE45TE025EDFDE45TE032EDFDE45TE040EDFDE45TE050EDFDE45TE063EDFDE45TE080GDFDE45TE100GDFDE45TE125GDFDE45TE160GD

Ref. nr.

433926433928433930433932433934433936433938433940433942433944433946

433948433949433950433951433952433953433954436145436146436147436148

435207 435229435231435238435240435242435244435246435248435256435258

430008430009430010430011430012430013430014430299430302430305433569

433697433699433701433703433705433707433709433711433713433715433717

In (A)

1620253240506380100125160

1620253240506380100125160

1620253240506380100125160

1620253240506380100125160

1620253240506380100125160

Cat. nr.

FDC35TE016EFFDC35TE020EFFDC35TE025EFFDC35TE032EFFDC35TE040EFFDC35TE050EFFDC35TE063EFFDC35TE080GFFDC35TE100GFFDC35TE125GFFDC35TE160GF

FDC35TE016EDFDC35TE020EDFDC35TE025EDFDC35TE032EDFDC35TE040EDFDC35TE050EDFDC35TE063EDFDC35TE080GDFDC35TE100GDFDC35TE125GDFDC35TE160GD

FDE36TF016EFFDE36TF020EFFDE36TF025EFFDE36TF032EFFDE36TF040EFFDE36TF050EFFDE36TF063EFFDE36TF080GFFDE36TF100GFFDE35TF125GFFDE35TF160GF

FDE35TC016EFFDE35TC020EFFDE35TC025EFFDE35TC032EFFDE35TC040EFFDE35TC050EFFDE35TC063EFFDE35TC080GFFDE35TC100GFFDE35TC125GFFDE35TC160GF

FDE35TE016EDFDE35TE020EDFDE35TE025EDFDE35TE032EDFDE35TE040EDFDE35TE050EDFDE35TE063EDFDE35TE080GDFDE35TE100GDFDE35TE125GDFDE35TE160GD

Ref. nr.

433532433553433864433867436870436873436876436879436882433885433899

433907433911433914433918436117436118436133436143436144433924433925

435127435129435130435132435135435138435145435147435193435195435205

430001430002430003430004430005430006430007430276430279430282433566

433649433651433653433655433657433659433661433663433665433667433669

One code covers a standard, fixed front connection breaker with:* Fixation hardware.

One code covers a standard, fixed front connection breaker with :* DIN-Rail mounting kit * Breaker finishing covers * Fixation hardware.

4 pole 4 trips(1)3 pole 3 trips

18 kAFDC

18 kAFDC

25kAFDE

25kAFDE

25kAFDE

FD63/160 - Complete Circuit BreakerLine Thermal Magnetic LTM (fixed settings)

Line Thermal Magnetic LTM (adjustable thermals)

3 pole 3 trips 4 pole 4 trips(1)

3 pole 3 trips 4 pole 4 trips(1)

3 pole 3 trips 4 pole 4 trips(1)

3 pole 3 trips 4 pole 4 trips(1)

One code covers a standard, fixed front connection breaker with :* DIN-Rail mounting kit * Breaker finishing covers * Fixation hardware.

One code covers a standard, fixed front connection breaker with :* Fixation hardware.

One code covers a standard, fixed front connection breaker with :* DIN-Rail mounting kit * Breaker finishing covers * Fixation hardware.

(1) Neutral on the left. If neutral on the right is needed, please contact us.

A

How

to

orde

r

GE Power ControlsA.6

How

to

orde

r

36 kAFDS

50kAFDN

240V25kAFDN

50kAFDN

80kAFDH

150kAFDL

Cat. nr.

------

FDN456TD063EDFDN456TD080GDFDN456TD100GDFDN456TD125GDFDN456TD160GD

------

FDH456TD063EDFDH456TD080GDFDH456TD100GDFDH456TD125GDFDH456TD160GD

----

FDL456TD063EDFDL456TD080GDFDL456TD100GDFDL456TD125GDFDL456TD160GD

Cat. nr.

FDH13TF016EFFDH13TF020EFFDH13TF025EFFDH13TF032EFFDH13TF040EFFDH13TF050EFFDH13TF063EFFDH13TF080GFFDH13TF100GFFDH13TF125GFFDH13TF160GF

FDN46TD016EDFDN46TD020EDFDN46TD025EDFDN46TD032EDFDN46TD040EDFDN46TD050EDFDN46TD063EDFDN46TD080GDFDN46TD100GDFDN46TD125GDFDN46TD160GD

FDH46TD016EDFDH46TD020EDFDH46TD025EDFDH46TD032EDFDH46TD040EDFDH46TD050EDFDH46TD063EDFDH46TD080GDFDH46TD100GDFDH46TD125GDFDH46TD160GD

FDL46TD025EDFDL46TD032EDFDL46TD040EDFDL46TD050EDFDL46TD063EDFDL46TD080GDFDL46TD100GDFDL46TD125GDFDL46TD160GD

Ref. nr.

433246433255433262433268433274433280433286433292433298433304433310

430131430132430133430134430135430136430137430752430755430758433590

430051430052430053430054430055430056430057430460430463430466435839

430090430091430092430093430094430591430594430597435854

Cat. nr.

FDS45TD016EDFDS45TD020EDFDS45TD025EDFDS45TD032EDFDS45TD040EDFDS45TD050EDFDS45TD063EDFDS45TD080GDFDS45TD100GDFDS45TD125GDFDS45TD160GD

FDN436TD016EDFDN436TD020EDFDN436TD025EDFDN436TD032EDFDN436TD040EDFDN436TD050EDFDN436TD063EDFDN436TD080GDFDN436TD100GDFDN436TD125GDFDN436TD160GD

FDH436TD016EDFDH436TD020EDFDH436TD025EDFDH436TD032EDFDH436TD040EDFDH436TD050EDFDH436TD063EDFDH436TD080GDFDH436TD100GDFDH436TD125GDFDH436TD160GD

FDL436TD025EDFDL436TD032EDFDL436TD040EDFDL436TD050EDFDL436TD063EDFDL436TD080GDFDL436TD100GDFDL436TD125GDFDL436TD160GD

Ref. nr.

430224430226430228430230430232430241432964432967432970432973433604

430117430118430119430120430121430122430123430688430691430694433578

430037430038430039430040430041430042430043430396430399430402435827

430082430083430084430085430086430557430560430563435848

In (A)

1620253240506380100125160

1620253240506380100125160

1620253240506380100125160

In (A)

1620253240506380100125160

1620253240506380100125160

253240506380100125160

Cat. nr.

FDS35TD016EDFDS35TD020EDFDS35TD025EDFDS35TD032EDFDS35TD040EDFDS35TD050EDFDS35TD063EDFDS35TD080GDFDS35TD100GDFDS35TD125GDFDS35TD160GD

FDN66TD016EDFDN66TD020EDFDN66TD025EDFDN66TD032EDFDN66TD040EDFDN66TD050EDFDN66TD063EDFDN66TD080GDFDN66TD100GDFDN66TD125GDFDN66TD160GD

FDN13TF016EFFDN13TF020EFFDN13TF025EFFDN13TF032EFFDN13TF040EFFDN13TF050EFFDN13TF063EFFDN13TF080GFFDN13TF100GFFDN13TF125GFFDN13TF160GF

FDN36TD016EDFDN36TD020EDFDN36TD025EDFDN36TD032EDFDN36TD040EDFDN36TD050EDFDN36TD063EDFDN36TD080GDFDN36TD100GDFDN36TD125GDFDN36TD160GD

FDH36TD016EDFDH36TD020EDFDH36TD025EDFDH36TD032EDFDH36TD040EDFDH36TD050EDFDH36TD063EDFDH36TD080GDFDH36TD100GDFDH36TD125GDFDH36TD160GD

FDL36TD025EDFDL36TD032EDFDL36TD040EDFDL36TD050EDFDL36TD063EDFDL36TD080GDFDL36TD100GDFDL36TD125GDFDL36TD160GD

Ref. nr.

430161430163430165430167430169430178432952432955432958432961433602

430143430144430145430146430147430148430149430794430797430800433599

433316433322433328433334433340433346433352433519433522433525433527

430100430101430102430103430104430105430106430630430633430636433572

430020430021430022430023430024430025430026430338430341430344435821

430070430071430072430073430074430518430521430524435845

Ref. nr.

------

430129430718430721430724433584

------

430049430426430429430432435833

----

430087430568430571430574435851

One code covers: A standard fixed front connection breaker + DIN-Rail mounting kit + Toggle elongator + Breaker finishing covers + Fixation hardware

One code covers: A standard fixed front connection breaker + DIN-Rail mounting kit + Toggle elongator + Breaker finishing covers + Fixation hardware

4 pole 3 trips(1)3 pole 3 trips 4 pole 3.5 trips (N=50%)(1)4 pole 4 trips(1)

3 pole 3 trips 4 pole 4 trips(1)

2 pole 2 trips

1 pole 1 trip1 pole 1 trip

240V50kAFDH

(1) Neutral on the left. If neutral on the right is needed, please contact us.

FD63/160 - Complete Circuit BreakerSelective Thermal Magnetic LTMD (settable thermals)

Line Thermal Magnetic LTM (fixed settings)

Selective Thermal Magnetic LTMD (settable thermals)

A

A.7

FD frame

Cat. nr.

----

FDN456TG063EDFDN456TG080GDFDN456TG100GDFDN456TG125GDFDN456TG160GD

----

FDH456TG063EDFDH456TG080GDFDH456TG100GDFDH456TG125GDFDH456TG160GD

Cat. nr.

FDN46TG025EDFDN46TG032EDFDN46TG040EDFDN46TG050EDFDN46TG063EDFDN46TG080GDFDN46TG100GDFDN46TG125GDFDN46TG160GD

FDH46TG025EDFDH46TG032EDFDH46TG040EDFDH46TG050EDFDH46TG063EDFDH46TG080GDFDH46TG100GDFDH46TG125GDFDH46TG160GD

Ref. nr.

430138430139430140430141430142430771430774430777433593

430058430059430060430061430062430479430482430485435842

Cat. nr. Ref. nr.

----

430130430729430732430735433587

----

430050430437430440430443435836

50 kAFDN

80kAFDH

50kAFDN

80kAFDH

150kAFDL

FDY

FDN436TG025EDFDN436TG032EDFDN436TG040EDFDN436TG050EDFDN436TG063EDFDN436TG080GDFDN436TG100GDFDN436TG125GDFDN436TG160GD

FDH436TG025EDFDH436TG032EDFDH436TG040EDFDH436TG050EDFDH436TG063EDFDH436TG080GDFDH436TG100GDFDH436TG125GDFDH436TG160GD

FDN436MC003EDFDN436MC007EDFDN436MC012EDFDN436MC020EDFDN436MC030EDFDN436MC050EDFDN436MC080GDFDN436MC100GD

FDH436MC003EDFDH436MC007EDFDH436MC012EDFDH436MC020EDFDH436MC030EDFDH436MC050EDFDH436MC080GDFDH436MC100GD

FDL436MC020EDFDL436MC030EDFDL436MC050EDFDL436MC080GDFDL436MC100GD

FDY406D063EDFDY406D160GD

Ref. nr.

430124430125430126430127430128430707430710430713433581

430044430045430046430047430048430415430418430421435830

436411430112430113430114430115430116430668430671

436398430032430033430034430035430036430376430379

430077430078430079430537430540

430151430810

In (A)

253240506380100125160

253240506380100125160

In (A)

37

12.520305080100

37

12.520305080100

20305080100

In (A)

63160

Cat. nr.

FDN36TG025EDFDN36TG032EDFDN36TG040EDFDN36TG050EDFDN36TG063EDFDN36TG080GDFDN36TG100GDFDN36TG125GDFDN36TG160GD

FDH36TG025EDFDH36TG032EDFDH36TG040EDFDH36TG050EDFDH36TG063EDFDH36TG080GDFDH36TG100GDFDH36TG125GDFDH36TG160GD

FDN36MC003EDFDN36MC007EDFDN36MC012EDFDN36MC020EDFDN36MC030EDFDN36MC050EDFDN36MC080GDFDN36MC100GD

FDH36MC003EDFDH36MC007EDFDH36MC012EDFDH36MC020EDFDH36MC030EDFDH36MC050EDFDH36MC080GDFDH36MC100GD

FDL36MC020EDFDL36MC030EDFDL36MC050EDFDL36MC080GDFDL36MC100GD

FDY306D063EDFDY306D160GD

Ref. nr.

430107430108430109430110430111430649430652430655433575

430027430028430029430030430031430357430360430363435824

436409430095430096430097430098430099430610430613

436396430015430016430017430018430019430318430321

430065430066430067430498430501

430150430805

FD63/160 - Complete Circuit BreakerGenerator Thermal Magnetic GTM (settable thermals)

Motor Protection (Mag BreakTM) Magnetic Only Breakers

Complete Non-Automatic Circuit Breaker (Switch)

4 pole 3 trips(1)3 pole 3 trips 4 pole 3.5 trips (N=50%)(1)4 pole 4 trips(1)

One code covers: A standard fixed front connection breaker + DIN-Rail mounting kit + Toggle elongator +Breaker finishing covers + Fixation hardware

One code covers: A standard fixed front connection breaker + DIN-Rail mounting kit + Toggle elongator +Breaker finishing covers + Fixation hardware + IPXXB covers (Finger protection on connection clamps)

One code covers: A standard fixed front connection breaker + DIN-Rail mounting kit + Toggle elongator +Breaker finishing covers + Fixation hardware

(1) Neutral on the left. If neutral on the right is needed, please contact us.

4 pole(1)3 pole

4 pole(1)3 pole

A

GE Power ControlsA.8

How

to

orde

r

Aux. switch right mountedAux. switch left mountedBell alarm trip unitBell alarm RCD deviceBell alarm mechanism(1)

12V DC24V AC/DC48V AC/DC60V AC/DC110/130V AC/DC220/240V AC 250 V DC400/480V AC220/240V AC

24V AC/DC48V AC/DC60V AC/DC110V AC/DC220/250V AC/DC400/440V AC

Keylock for operator Ronis(2)

Keylock for operator Profalux(2)

Grey Red Grey + auxiliary contacts 2xNO(4)

Red + auxiliary contacts 2xNO(4)

Grey (max. 350 mm)Red (max. 350 mm)Grey + auxiliary contacts 2xNO(4)

Red + auxiliary contacts 2xNO(4)

Flex operator adaptor push to trip, set of 2 pcs. (a)Extension shaft kit (max. 600 mm) (b)Side-by-side installation adapter kit (c)

Ronis keylock 1104B nr. BC 1027(2) (d)Ronis keylock 1104B nr. BC 1053(2) (d)Ronis keylock 1104B nr. BC 2932(2) (d)Ronis keylock 1104B nr. BC 2911(2) (d)Ronis keylock 1104B nr. BC 2936(2) (d)Ronis keylock 1104B nr. BC 2940(2) (d)Ronis lock with random key(2) (d)Profalux lock with random key(2) (e)

Voltage 220/440V AC (a)Voltage 400/690V AC (a)

Voltage 220/440V AC (b)

Voltage 220/440V ACVoltage 400/690V AC

Bell Alarm RCD device

Cat. nr.

FAS10RFAS10LFABAT10FABAT10

-

FASHTBFASHTDFASHTFFASHTHFASHTJFASHTNFASHTU

-

FDEMFDFDEMFFFDEMFHFDEMFJFDEMFNFDEMF8

FD1BREFD1BPE

FDNRFFDNRFV

--

----

FDNFTFDNREFDNR4

FA1BR1FA1BR2FA1BR3FA1BR4FA1BR5FA1BR6FA1BRHFA1BPH

FDQDS3MFDQDS3H

FDQDI3M

FDQDB3MFDQDB3H

FABAT10

Ref. nr.

430837430834430818430818

-

430840430843430846435118430849430852430855

-

430926430929430932430935430938430920

430877430876

430989430992

--

----

430968430986430971

430088430089430504430505430506430507430068430813

431013433542

433388

433370433364

430818

Cat. nr.

FAS01RFAS01LFABAT01FABAT01

-

FAUVRDFAUVRFFAUVRHFAUVRJFAUVRNFAUVRU

-

FDNRCFDNRCVFDNRYFDNRYV

----

FDQDS4MFDQDS4H

FDQDI4M

FDQDB4MFDQDB4H

FABAT 01

Ref. nr.

430831430828430815430815

-

430861430864434120430867430870430873

-

430974430977430998433361

----

431022433548

433397

433379433373

430815

Cat. nr.

----

FDBAM11

-----

FAUVDN

----

FDNRDFDNRDVFDNRZFDNRZV

Ref. nr.

----

430880

-----

430858

----

430980430983431001431004

Normally closedNormally open Changeover

UndervoltageShunt

Only for use with panel or door mounted typeOnly for use with panel or door mounted typeNot for use with panel or door mounted type

One code covers an RCD with: DIN-Rail mounting kit & Multidirectional supply kit

One code covers an RCD with: DIN-Rail mounting kit and Interconnection kit.

One code covers an RCD with: Sealable connection cover (cut-out adaptor FDUF)

(1) Not for FDC and FDE types(2) Key included(3) Add door flange FDFH to allow use of the door interlock options

(4) On request 1xNO/1xNC is available.(5) Not possible on FDC and FDE types

Delayed undervoltage

Accessories

Normally closedNormally open

Rotary handle for usethrough door or cover plate(3)Direct on device Panel or door mounted

(a)

(c) (b)

(b)

(a)

(d)

(e)

4 pole3 poleStandard

Side connected only

FD - Internal accessoriesContacts

Releases

FD - OperatorsElectrical Operators

Rotary Handles

FD - Residual Current DevicesRCD Side Mounted(5)

RCD Bottom Mounted(5)

(below trip unit area)

A

A.9

FD frame

Cat. nr.

FDDDF3FDDFF3FDDMP3

FDDFQ3FDDMP3

FAPFMFAPF8FAPM8

FAPPS

FAPIP

FDBES3FDBEH3FDBEA3

FDBSS3

FDTCA1316

FDBRC3-

FDBRCS2FDBRCL2

FDJL3

FDJS3

FDJP

FDJB

FDJK

FDUF3

FBF6

Ref. nr.

430893430899430905

433489430905

430824430823430826

430827

430825

430887430885430883

430891

433400

430889-

433358433357

430951

430960

430957

430945

430069

430830

883970

Cat. nr.

FDDDF4FDDFF4FDDMP4

FDDFQ4FDDMP4

FDBES4FDBEH4FDBEA4

FDBSS4

FDTCA1416

-FDBRC4

--

FDJL4

FDJS4

FDUF4

-

Ref. nr.

430896430902430908

433492430908

430888430886430884

430892

433401

-430890

--

430954

430963

430832

-

4 pole3 pole

4 pole3 pole

4 pole3 pole

Complete set: Fixed and mobile part with connection and fixation hardwareFixed part: Fixed base with connection and fixation and hardware Mobile part: Mechanism trip device, terminal shields and set of 3 or 4 pole plugs

(1) Plug-in system max. 125A.(2) Only necessary when internal accessories or an electrical operator areused.

(3) External box clamps are always delivered with standard extender(4) Set for equipping the line OR load side of breaker.(5) Supplied with mag. break types.

Complete set for breakerFixed part for breakerMobile part for breaker

Fixed part for breaker & RCDMobile part for breaker & RCD

Complete set 8 poleFixed part 8 poleMobile part 8 pole

Plug and socket 10 pole

Insertion prevention kit (of ….wrong A rating)

Standard flat type (a)Heightened type (b)Twisted 90° (c)

Pole spacing 35 mm

Cable Cu/Al 95 mm2(3)

Set 3 pole (2 short, 1 long)Set 4 pole (2 short, 2 long)

Spares, set of 2 short typesSpares, set of 2 long types

Long, set of 2 pcs.

Short, set of 2 pcs.

Phase separators, set of 12 pcs.

Backplate set of 2 pcs. (3 or 4 pole)

Finger protection IPXXB (set of 12 pcs)(5)

Cutout adaptor, Breaker + Trip unit

Cutout filler for cover plate (64 mm), length of 1.2 m

(a) (b) (c)

FD - Plug-in System(1)

Main systemComplete

Fixed Mobile

Auxiliary disconnects Secondary wiring(2)

Insertion prevention kit

FD - Connections: Optional(4)

Extenders

Spreaderflat

External Box Clamps

Rear Connections

FD - Installation AccessoriesTerminal shields

(with finishing covers)

Specific to connection area

Covers

A

How

to

orde

r

GE Power ControlsA.10

How

to

orde

r

Padlocking removable

Padlocking fixed

Set of 20 blank labels

Length = (18 modules of 18 mm) 354 mm

Breaker front face and RCDRotary handle (through cover plate model)

Electrical operator

DIN-rail adaptor kit(2)

Finishing covers, set of 2 pcs.(2)

Spare toggle (set of 5 pieces)

Cat. nr.

FD1PR

FD1PF

FAC

FDKE

FDFF3FDFH

FDFE

FDKD3

FDUA3

FDUT

Ref. nr.

430879

430878

430821

617947

430941430829

432010

430966

431025

433539

Cat. nr.

FDFF4-

-

FDKD4

FDUA4

-

Ref. nr.

430942-

-

430967

431026

-

(1) Padlocks not included(2) Supplied with breakers, not with FDC and FDE types

4 pole3 pole

FD - Installation Accessories (continued)

Padlocking devices for toggle operator(1)

Circuit indication/coding

Heightning set for ElfaPlus MCB's

Door Flanges

Spare parts


Recommended