+ All Categories
Home > Documents > Flowmeters & Monitors - Farnell · PDF fileNegligible pressure drop characteristics. ......

Flowmeters & Monitors - Farnell · PDF fileNegligible pressure drop characteristics. ......

Date post: 05-Feb-2018
Category:
Upload: phungkiet
View: 215 times
Download: 0 times
Share this document with a friend
12
Flowmeters & Monitors FDHB347UK August 2007
Transcript
Page 1: Flowmeters & Monitors - Farnell · PDF fileNegligible pressure drop characteristics. ... Simple to fit, easy to use The LoFlow meter has been designed ... Inline Flow Transmitter Flowmeters

Flowmeters & Monitors

FDHB347UKAugust 2007

Page 2: Flowmeters & Monitors - Farnell · PDF fileNegligible pressure drop characteristics. ... Simple to fit, easy to use The LoFlow meter has been designed ... Inline Flow Transmitter Flowmeters

Parker HannifinHydraulic Filter Division EuropeFDHB347UK.

• Consistent quality• Technical innovation• Premier customer service

Parkers technical resources provide the best filtration technologies that conform to your requirements. That’s why thousands of manufacturers and equipment users around the world rely on Parker Filtration products and people.

Worldwide Salesand Service

Parker operates sales and service centres in major industrial areasworldwide. Call 1-800-C-PARKER for more product information in Northand South America and 00800 27275374 for theEuropean Product Information Centre (24 Hr).

Hydraulic, Lubrication &Coolant Filtration

High-performance filtrationsystems for productionmachinery in industrial, mobileand military/marine applications.

Compressed Air &Gas Filtration

Complete line of compressedair/gas filtration products;coalescing, particulate andadsorption filters in manyapplications in many industries.

Process & ChemicalFluid Filtration

Liquid filtration systems forbeverage, chemical and foodprocessing; cosmetic, paint,water treatment; photo-processing; and micro-chipfabrication.

Racor Fuel Conditioning& Filtration

Parker air, fuel and oil filtrationsystems provide qualityprotection for engines operatingin any environment, anywherein the world.

System ContaminationMonitoring

On-line dynamic particleanalysis, off-line bottlesampling and fluid analysis andmeasurement of water contentpolluting the oil in a system. All important and achievable,cost-effective solutions availableto equipment manufacturers and end users alike.

Photo courtesy of GLASBAU HAHN.

WARNINGFAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THEPRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATEDITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY

DAMAGE.

This document and other information from Parker Hannifin Corporation, itssubsidiaries and authorized distributors provide product and/or systemoptions for further investigation by users having technical expertise. It isimportant that you analyze all aspects of your application and review the

information concerning the product or system in the current productcatalog. Due to the variety of operating conditions and applications for

these products or systems, the user, through its own analysis and testing,is solely responsible for making the final selection of the products and

systems and assuring that all performance, safety and warningrequirements of the application are met.

The products described herein, including without limitation, product features,specifications, designs, availability and pricing, are subject to change by

Parker Hannifin Corporation and its subsidiaries at any time without notice.

Offer of SaleThe items described in this document are hereby offered for sale by Parker

Hannifin Corporation, its subsidiaries or its authorized distributors. This offer andits acceptance are governed by the provisions stated in the "Offer of Sale".

Page 3: Flowmeters & Monitors - Farnell · PDF fileNegligible pressure drop characteristics. ... Simple to fit, easy to use The LoFlow meter has been designed ... Inline Flow Transmitter Flowmeters

A range of cost saving solutions

Flowmeters & monitors

Flowmeters & Monitors

3

Page 4: Flowmeters & Monitors - Farnell · PDF fileNegligible pressure drop characteristics. ... Simple to fit, easy to use The LoFlow meter has been designed ... Inline Flow Transmitter Flowmeters

Flowmeters & Monitors

LoFlow - Oil and Water Flowmeters

Specification Installation Details

Construction:Body Grillon TR55.Back body half ABS 7020.Ball retainer ABS 7020.Back panel PVC.Float See below.

Maximum working pressure:10 bar.

Maximum workingtemperature:60°C.

Accuracy:±2% typical.

Repeatability:±1%.

Connections:1/4” and 3/4” tapered threads.

Installation Details Ordering Information

Typical Applications

Features & Benefits

Easy to read, permanent printed scales.Large scale definition for precise measurement.Easy panel mounting assembly.Negligible pressure drop characteristics.10 bar pressure rating.Simple to use.

Parker HannifinHydraulic Filter Division EuropeFDHB347UK.

4

Simple to fit, easy to use

The LoFlow meter has been designed for those industrieswhere the need exists for a low cost solution to smallmeasurements of flow with an accurate reading. LoFlowuses the well tried and tested principle of variable area flowmeasurement utilising the movement of a ball or float insidea calibrated tapered bore.

Pharmaceutical industryFiltration systemsHospital equipmentFor water applications

Water treatmentPhotography and X-rayEquipmentSwimming pools

Outlet port R 3/4

3924

1414

188

40

Inlet portR1/4 / R3/4

4410

1

16

4 off ‘push out’fixing slots Ø6 X 8 LG

Product number

LF802412LF802413LF802414LF801431LF802432LF802434LF801411

Supersedes

LF.2020LF.2100LF.2220LF.1002LF.1009LF.1090LF.2005

Media

WaterWaterWater

OilOilOil

Water

Ports (BSPT male)

3/4 - 3/4

3/4 - 3/4

3/4 - 3/4

1/4 - 3/4

3/4 - 3/4

3/4 - 3/4

1/4 - 3/4

Flow range(l/min)

0.2 - 2.02.0 - 10.03.0 - 22.0

0.010 - 0.200.1 - 0.91.0 - 9.0

0.06 - 0.55

Float material

AcetalS/SteelS/SteelS/SteelAcetalS/SteelS/Steel

Standard products table

Note 1: Part numbers featured with bold highlighted codes will ensure a‘standard’ product selection.Note 2: Alternate displayed part number selection will require you to contactParker Filtration for availability.

Item is standardItem is standard green optionItem is semi standardItem is non standard

123123123123

Highlights Key (Denotes part number availability)

Note: Standard items are in stock, semi standard items are available within four weeks

Page 5: Flowmeters & Monitors - Farnell · PDF fileNegligible pressure drop characteristics. ... Simple to fit, easy to use The LoFlow meter has been designed ... Inline Flow Transmitter Flowmeters

Flowmeters & Monitors

Easiflow - Meters and Flowswitches

Flowmeters & monitors

Installation Details

Features & Benefits

5

Easiflow Meters Specification Flowswitch SpecificationsConstruction:Cone AcetalViewing glass Borosilicate glassCalibrated spring Stainless steelSeal NitrileBody Glass filled nylonMaximum working pressure:10 bar.Minimum working pressure:1 bar.Temperature range:+5°C to +80°C - Oil.+5°C to +60°C - Water.

Flow rate:1 to 150 l/min.Viscosity range:10 to 200 centistokes (oil).Accuracy:±5% FSD.Repeatability:±1% FSD.Connections:1” BSP parallel threads.Weight:0.4kg.

Oil and water calibrated.Works in any plane.Pressures up to 10 bar.Flows from 1 to 150 I/min.Accuracy ±5% FSD.Repeatability ±1% FSD.Switches – fully adjustable flow rate signalling.Plant and equipment protection.

The Easiflow switch is a flow measuring device incorporatingan AC/DC switch suitable for controlling valves or pumpmotors or for activating alarm signals.

General flowmeter specification:See material details opposite.

Switch type specifications:Magnetically operated reed switch.

Electrical details:Voltage range 300Vac/dcMaximum current 2.5AmpsMaximum load 100W resistive

70W inductive

15620

196

Ø60

Ø40

42 A/F HEX

42 A/F HEX

Ø40

15620

196

Ø60

106

Ordering Information

Product number

EF7731111220EF7731112220EF7731113220EF7731114220EF7731110120EF7731111120EF7731112120EF7731113120EF7731114120EF7731110220

Supersedes

EFW.0302EFW.0502EFW.1002EFW.1502EFL.0151EFL.0301EFL.0501EFL.1001EFL.1501EFW.0152

Media

WaterWaterWaterWater

OilOilOilOilOil

Water

Flow range(l/min)

2 - 304 - 505 - 10010 - 1501 - 152 - 304 - 505 - 10010 - 1501 - 15

Standard products table

Note 1: Part numbers featured with bold highlighted codes willensure a ‘standard’ product selection.Note 2: Alternate displayed part number selection will requireyou to contact Parker Filtration for availability.

Product number

EF7731110221EF7731111221EF7731110121EF7731111121EF7731112121EF7731113121EF7731114121EF7731112221EF7731113221EF7731114221

Supersedes

EFW.015S1EFW.030S1EFL.015S1EFL.030S1EFL.050S1EFL.100S1EFL.150S1EFW.050S1EFW.100S1EFW.150S1

Media

WaterWater

OilOilOilOilOil

WaterWaterWater

Flow range(l/min)

1 - 152 - 301 - 152 - 304 - 505 - 10010 - 1504 - 505 - 10010 - 150

Switch range(l/min)

5 - 155 - 305 - 155 - 3010 - 5020 - 10030 - 15010 - 5020 - 10030 - 150

Standard products table

Note 1: Part numbers featured with bold highlighted codes willensure a ‘standard’ product selection.Note 2: Alternate displayed part number selection will requireyou to contact Parker Filtration for availability.

Page 6: Flowmeters & Monitors - Farnell · PDF fileNegligible pressure drop characteristics. ... Simple to fit, easy to use The LoFlow meter has been designed ... Inline Flow Transmitter Flowmeters

Flowmeters & Monitors

Dataflow - 4 to 20mA and PulseOutput Flow Transmitters

Features & Benefits

Parker HannifinHydraulic Filter Division EuropeFDHB347UK.

6

Specification Installation Details

Construction:Borosilicate glasstube.Nitrile seals.Body – Glass filled nylon.Rotor and locater – Acetal.Washers and shaft – Stainless steel.Rotor tips – Stainless steel.

Max. working pressure:10 bar oil/water.

Flow indication:Min: 2 I/min.Max: 150 l/min.Accepts reverse flow.

Accuracy:±2% FSD.

Temp range:+5°C to +80°C oil.+5°C to +60°C water.

Connections:1” BSP parallel threads.

Weight:0.7Kg.

Calibration 4 to 20mA:4mA = 0 l/min,20mA = 100 l/min.

Calibration pulse output per litre:‘K’ factors.Oil = 51.14Water = 44.25

Electrical details 4 to 20mA:Supply = 24Vdc.

Pulse output:Supply = 24Vdc.(open collector transistor).

Digital Display Specification (DFT 990 only)

4 to 20mA output.Pulse output available for totalising/batching.Works in any plane.Accepts reverse flow.Maximum flow 150 l/min.Negligible pressure drop.Pressures up to 10 bar.Low cost. Simple to install.For use with most liquids.Factory calibrated. Accuracy ±2%.DIN plug connector (included).

156

196

Ø40

20

42 A/F HEX

Ø60

106

Ordering Information

Dataflow 4-20mAtransmitter can beconnected to a DigitalDisplay Unit (DDU1001or DDU1002)

4 to 20mA On-Site CalibrationSet your system to zero flow. Connect a multimeter acrossterminals 1 (+20mA) and (0mA) (Dia. 2). Set the zero to read4mA on your multimeter (Dia. 1). Set your system to full flowand set the span to read 20mA on your multimeter. (Dia. 1)

Diagram 1 Diagram 2

Spa

n

Zero

Flow setup Plug wiring

Slider

Set zero flowto 4mA

Set full flowto 20mA

EarthOVpower

0mA

+20mA+24vpower

1 2

For indicator options please refer to MS150 section of thecatalogue, reference DDU1001 and DDU1002 indicators

Note: Minimum span setting = 30 I/min

Product number

DFT980DFT990

Supersedes

DFT.980DFT.990

Description

Dataflow "Pulse" output transmitterDataflow 4-20mA transmitter

Standard products table

Note 1: Part numbers featured with bold highlighted codes will ensure a ‘standard’ product selection.Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for availability.

Page 7: Flowmeters & Monitors - Farnell · PDF fileNegligible pressure drop characteristics. ... Simple to fit, easy to use The LoFlow meter has been designed ... Inline Flow Transmitter Flowmeters

Flowmeters & Monitors

Dataflow Compact - Inline FlowTransmitter

Flowmeters & monitors

Features & Benefits

7

Specification

Construction:Body Grilamid – TR55.Rotor 18% PTFE filled

nylon.Shaft Stainless steel.ShaftRetainers Grilamid TR55.

Operation:Infra-red.

Maximum working pressure:20 bar.

Pressure drop:Max 0.1 bar at 15 l/min.

Flow range:1 to 25 I/min.(Accepts reverse flow).

Calibration:‘K’ Factor 752 pulses per litre,typical.Subject to application.

Accuracy:±2% typical.

Repeatability:±1%.

Temperature range:+5°C to +70°C.

Overall dimensions:52mm x 29mm x 27mm.

Weight:16 grams.

Connections:3/8 BSP

Cable length:300mm.

Power supply:5 Vdc.

Output signal:5 Vdc - square wave

Installation Details

Ordering Information

Pulse output signal for flows up to 25 l/min.Lightweight and robust.Operates in any plane. Simple to install.Low cost flow measurement.Negligible pressure drop.Accepts reverse flow.3/8 BSP male connection.Water or compatible clear fluids only.Ideal for washing machines, showers andvending machines.

Dataflow Compact – The Low Cost Transmitter

The Dataflow Compact Transmitter was designed to offerOEM’s and end users alike a means of monitoring low flowson liquids with an electronic output signal – but at LOW COST.Fluid passes through the one piece sensor body impacting onthe twin vaned turbine rotor, causing it to rotate at a speedproportional to the flow rate. Two opposing photo-transistorsare mounted either side of the rotor and externally of the clearsensor body, these generate a continuous signal.

As the rotor spins each blade obscures the infra red signal.This is then converted into an industry standard pulse outputsignal – compatible with inexpensive display units for flow rate,totalising, batch control and large, central control systems.The lightweight Grilamid body with its virtually unrestricted flowpath, offers negligible pressure drop for flows up to 25 I/minand withstanding pressures up to 20 bar.

Flow Rate • Totalising • Batch Control and applicationsin many industries

Dataflow Compact Transmitters are small and very robusthaving been developed and tested extensively in industryapplications where space is a restriction. Dataflow Compactwith its Grilamid body and BSP connections can be installedalmost anywhere and once installed will give accurate andreliable output signalling.

Red wire +5V supplyGreen wire Output signalBlue wire 0V supply

12.0 TYP

8.0 TYP

20.0

3.5

52.0

ISO

228

G3 /

8

34.0

Standard products table

Note 1: Part numbers featured with bold highlighted codes will ensure a ‘standard’ product selection.Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for availability.

Product number

DFC9000100

Supersedes

DFC.9000.100

Description

Dataflow compact transmitter

Page 8: Flowmeters & Monitors - Farnell · PDF fileNegligible pressure drop characteristics. ... Simple to fit, easy to use The LoFlow meter has been designed ... Inline Flow Transmitter Flowmeters

Flowmeters & Monitors

Flowline - Oil and Water CalibratedFlowmeters (Brass Version)

Features & Benefits

Parker HannifinHydraulic Filter Division EuropeFDHB347UK.

8

Works in any plane.Pressure up to 350 bar (5000 psi).Flows up to 360 l/min.Accuracy ±5% FSD.Repeatability ±1% FSD.Direct reading.Relatively insensitive to viscosity changes.Oil or water calibrated.Optional reed switch upgrade.

Ordering Information - Oil

Ordering Information - Water

Specification

Construction:Brass body to BS 2874 CZ114.Maximum working pressure:Up to 350 bar.

Minimum working pressure:1 bar.Temperature range:Brass –20°C to +90°C.Calibration:Oil Specific gravity

0.856 at 20°C.Water Specific gravity

1.0 at 20°C.

Viscosity range:10 to 200 cSt (oil).Accuracy:±5% FSD.Repeatability:±1% FSD.Min. scale reading:10% FSD.Connections:BSP parallel threads.Wetted/non-wetted parts:Consult Parker for information.

1/4”, 1/2” and 3/4” BSP thread options

DE

ØCBA ØF

Note: To add an electrically operated reed switch to your flowmeterplease order B26307

Product number

Brass flowmeter for oil Dimensions (mm)

FM26122212FM26122312FM26222112FM26222212FM26322112FM26322212FM26122112FM26422112FM26422212FM26422312

Supersedes

FM.26 122 212FM.26 122 312FM.26 222 112FM.26 222 212FM.26 322 112FM.26 322 212FM.26 122 112FM.26 422 112FM.26 422 212FM.26 422 312

PortsBSP

1/4

1/4

1/2

1/2

3/4

3/4

1/4

11/4

11/4

11/4

Flow range(l/min)

0.5 - 4.51 - 92 - 205 - 465 - 55

10 - 1100.2 - 2.020 - 18030 - 27040 - 360

Maximumpressure (bar)

350350350350350350350210210210

A(A/F Hex)

32324141585832

B(A/F Hex)

29293838464629

C

19193232434319

D

123123

165.5165.5190190123

E

77

12.512.515157

F

32324646585832

Weight(kg)

0.40.40.90.91.751.750.48.08.08.0

Standard products table

For intallation details for 11/4 flowmeters see next page

Product number

Brass flowmeter for water Dimensions (mm)

FM26222122FM26222222FM26322122FM26322222FM26122122FM26122222FM26122322FM26422122FM26422222FM26422322

Supersedes

FM.26 222 122FM.26 222 222FM.26 322 122FM.26 322 222FM.26 122 122FM.26 122 222FM.26 122 322FM.26 422 122FM.26 422 222FM.26 422 322

PortsBSP

1/2

1/2

3/4

3/4

1/4

1/4

1/4

11/4

11/4

11/4

Flow range(l/min)

2 - 205 - 465 - 55

10 - 1100.2 - 2.00.5 - 4.5

1 - 920 - 18030 - 27040 - 360

Maximumpressure (bar)

350350350350350350350210210210

A(A/F Hex)

41415858323232

B(A/F Hex)

38384646292929

C

32324343191919

D

165.5165.5190190123123123

E

12.512.51515777

F

46465858323232

Weight(kg)

0.90.91.751.750.40.40.48.08.08.0

Standard products table

For intallation details for 11/4 flowmeters see next page

Note 1: Part numbers featured with bold highlighted codes will ensure a ‘standard’ product selection.Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for availability.

Page 9: Flowmeters & Monitors - Farnell · PDF fileNegligible pressure drop characteristics. ... Simple to fit, easy to use The LoFlow meter has been designed ... Inline Flow Transmitter Flowmeters

Flowmeters & Monitors

Flowline - Oil and Water CalibratedFlowmeters (Stainless Steel)

Flowmeters & monitors

Features & Benefits

9

Ordering Information - Oil

Ordering Information - Water

Specification

Construction:Stainless steel to BS 970 316S.

Maximum working pressure:Up to 350 bar.

Minimum working pressure:1 bar.

Temperature range:–20°C to +105°C.

Calibration:Oil Specific gravity

0.856 at 20°C.Water Specific gravity

1.0 at 20°C.

Viscosity range:10 to 200 cSt (oil).

Accuracy:±5% FSD.

Repeatability:±1% FSD.

Min. scale reading:10% FSD.

Connections:BSP parallel threads.

11/4” BSP option308

251.532.5 5725 25

Ø87

Ø75

Ø76

Ø10

1.3

65 A

/F

65 A

/F

For flow measurement of corrosive, chemical media orin harsh locations.Manufactured in stainless steel 316.Works in any plane.Pressure up to 350 bar (5000 psi).Flows up to 360 l/min.Accuracy ±5% FSD.Repeatability ±1% FSD.Direct reading.Oil or water calibrated.Optional reed switch upgrade.

Wetted parts:Body, thread adaptor

Piston, etc: cone locknut:Stainless Steel.

Flow cone:BS 970 316S 16.

Magnet encapsulation:Stainless steel BS970/1:1991.:316S31.

Spring:Stainless steel to BS 2056 EN 58J.

Seal:Viton.

Note: To add an electrically operated reed switch to your flowmeter pleaseorder B26307

Product number

Stainless steel flowmeter for oil Dimensions (mm)

FM26232112FM26332112FM26332212FM26132112FM26132212FM26132312FM26232212FM26432112FM26432212FM26432312

Supersedes

FM.26 232 112FM.26 332 112FM.26 332 212FM.26 132 112FM.26 132 212FM.26 132 312FM.26 232 212FM.26 432 112FM.26 432 212FM.26 432 312

PortsBSP

1/2

3/4

3/4

1/4

1/4

1/4

1/2

11/4

11/4

11/4

Flow range(l/min)

2 - 205 - 55

10 - 1100.2 - 2.00.5 - 4.5

1 - 95 - 46

20 - 18030 - 27040 - 360

Maximumpressure (bar)

350350350350350350350350350350

A(A/F Hex)

41585832323241

B(A/F Hex)

38464629292938

C

32434319191932

D

165.5190190123123123

165.5

E

12.51515777

12.5

F

46585832323246

Weight(kg)

0.91.751.750.40.40.40.98.08.08.0

Standard products table

For intallation details for 11/4 flowmeters see above

Product number

Stainless steel flowmeter for water Dimensions (mm)

FM26132122FM26132222FM26132322FM26232122FM26232222FM26332122FM26332222FM26432122FM26432222FM26432322

Supersedes

FM.26 132 122FM.26 132 222FM.26 132 322FM.26 232 122FM.26 232 222FM.26 332 122FM.26 332 222FM.26 432 122FM.26 432 222FM.26 432 322

PortsBSP

1/4

1/4

1/4

1/2

1/2

3/4

3/4

11/4

11/4

11/4

Flow range(l/min)

0.2 - 2.00.5 - 4.5

1 - 92 - 205 - 465 - 55

10 - 11020 - 18030 - 27040 - 360

Maximumpressure (bar)

350350350350350350350350350350

A(A/F Hex)

32323241415858

B(A/F Hex)

29292938384646

C

19191932324343

D

123123123

165.5165.5190190

E

777

12.512.51515

F

32323246465858

Weight(kg)

0.40.40.40.90.91.751.758.08.08.0

Standard products table

For intallation details for 11/4 flowmeters see above

Note 1: Part numbers featured with bold highlighted codes will ensure a ‘standard’ product selection.Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for availability.

Page 10: Flowmeters & Monitors - Farnell · PDF fileNegligible pressure drop characteristics. ... Simple to fit, easy to use The LoFlow meter has been designed ... Inline Flow Transmitter Flowmeters

Flowmeters & Monitors

Flowline - Flowswitches

Features & Benefits

Parker HannifinHydraulic Filter Division EuropeFDHB347UK.

10

‘Boxed’ two-switch type.Intrinsically safe versions.Maximum/minimum switching models.Maximum working pressure 350 bar. (min 1 bar)Flows from 2.0 to 110 I/min.Stainless steel – suitable for corrosive media.Stainless steel to BS970 316S16.

To order the required switching unit, simply add the appropriate prefix before the part numbers shown below.

Ordering Information

Product number

FS643222112FS643222212FS643322112FS643322212

Supersedes

FS.643 222 112FS.643 222 212FS.643 322 112FS.643 322 212

Description

2 switches, 2 - 20 l/min (1/2 BSP) Oil2 switches, 5 - 46 l/min (1/2 BSP) Oil2 switches, 5 - 55 l/min (1/2 BSP) Oil

2 switches, 10 - 110 l/min (1/2 BSP) Oil

Note 1: Part numbers featured with bold highlighted codes will ensure a ‘standard’ product selection.Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for availability.

Standard products table

Product number

FS643FS67AFS67BFS67C

2 switchesIntrinsically safe high switchIntrinsically safe low switch

Intrinsically safe hi/low switch

Flow range and (port size)

2221222232213222

2 - 20 l/min (1/2 BSP)5 - 46 l/min (1/2 BSP)5 - 55 l/min (3/4 BSP)

10 - 110 l/min (3/4 BSP)

Fluid type

1222

OilWater

Product configuratorBrass flowswitch for oil or water

Product number

FS643FS67AFS67BFS67C

2 switchesIntrinsically safe high switchIntrinsically safe low switch

Intrinsically safe hi/low switch

Flow range and (port size)

2321232233213322

2 - 20 l/min (1/2 BSP)5 - 46 l/min (1/2 BSP)5 - 55 l/min (3/4 BSP)

10 - 110 l/min (3/4 BSP)

Fluid type

1222

OilWater

Product configuratorStainless steel flowswitch for oil or water

Product number

FS643332212

Supersedes

FS.643 332 212

Ordering example

Page 11: Flowmeters & Monitors - Farnell · PDF fileNegligible pressure drop characteristics. ... Simple to fit, easy to use The LoFlow meter has been designed ... Inline Flow Transmitter Flowmeters

Flowmeters & Monitors

Hydraulic Test Equipment

Flowmeters & monitors

Features & Benefits

11

Speedy diagnosis of hydraulic circuit faults.Flows ranging from 2 to 360 l/min.Measuring flow, pressure and temperature.Fully Portable – No power source required.Hydrotrac unit for flows from 2 to 110 I/min available.Designed for oil applications only.

Specification

Flow range:2 to 360 I/min.

Pressure range:1 to 350 bar.

Temperature range:0°C to +90°C.

Installation Details

Ordering Information

Hydraulic Test Units are designed specifically for the speedydiagnosis of hydraulic circuit faults in mobile, marine andindustrial systems using the normal range of mineral oils. Theirrugged construction based mainly on mild steel, manganesebronze and acrylic materials makes them ideally suited forarduous use in the field.

Each unit is supplied in a convenient carrying case providingfull protection and additional storage space for fittings.Because they need no power source such as batteries etc,they are always ready for instant use.

6 models are available to cover flow capacities up to 360 I/minand each incorporates a direct reading, uni-directional flowmeter. The meter, which is both self cleaning and reasonablytolerant of contaminated fluids is coupled to a manifold thathouses a glycerine-filled pressure gauge calibrated 0 to 350bar and a dial-type thermometer with a 0°C to 100°C range.

Unit can only operate up to 90°C.

For further convenience the scale on the flow meter can berotated to ensure visibility in any situation and the installedattitude of the assembly is not critical, though whenever possiblethe unit should be mounted with pressure gauge vertical andgauge case relief valve uppermost. The unit is designed for flowto be in the direction of the arrow on the flowmeter scale andmust not be installed with the flow reversed.

B

ØC

A A

/F H

EX

An axial flow restrictor valve is fitted which can be adjustedunder full load from open to fully closed, and to complete thespecification, a safety blow-out disc, set to fail at 455 bar isfitted to the manifold in a position facing away from theoperator when reading the gauges normally. Two spare blow-out discs are supplied which are easily replaced by removingthe hexagonal plug on the gauge manifold.

Additional blow out discs can be ordered - 41203B (Bag of 10)

Safety

Troubleshooting Test Units

Product number Dimensions (mm)

412141204123416841694170

Flow range (I/min)

10 - 1105 - 552 - 11020 - 18030 - 27040 - 360

Weight Kg(with case)

7.47.411.813.8513.8513.85

A

464646757575

B

350350350496496496

C

353535878787

Standard products table

Part number41203B

Supersedes4120.3.B

DescriptionSafety blow out discs x 10

Note 1: Part numbers featured with bold highlighted codes will ensure a ‘standard’ product selection.Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for availability.Note 3: 4123 ‘Hydrotrac’ unit features 2 flowmeters (2 - 20 and 10 - 110 l/min) and 1 pressure gauge and 1 thermometer.

Page 12: Flowmeters & Monitors - Farnell · PDF fileNegligible pressure drop characteristics. ... Simple to fit, easy to use The LoFlow meter has been designed ... Inline Flow Transmitter Flowmeters

Brochure Ref: FDHB347UKHydraulic Filter Division Europe

© Copyright 2007Parker Hannifin CorporationAll rights reserved.

Filtration website: www.parker.com/eurofiltFiltration email: [email protected] further information on other Parker Products, call EPIC free on 00800 27 27 5374

Flowmeters & Monitors

Flow Products - For Compressed Air Applications

Features & Benefits

Flowline Flowswitches andFlowmeters

Calibrated for direct reading of compressed air at 7 bar.Works in any plane.Brass or stainless steelmodels available in 4 sizes.Calibrated at 7 bar and 20°C.Flow ranges from 2 to 600 SCFM.Pressure 1-41 bar max.Optional reed switch upgrade.

Loflow Air FlowmetersFlow measurement from 1.1 to720 l/min. Max 10 bar rating.

Compressed Air Test Equipment6 models available – 1/4”, 3/4”and 11/4” BSP.Air flow range 2 to 600 SCFM. Pressure 1-41 bar max.

A

B

C

A B

C

A A

/F H

EX

ØC

D

Specification

Full technical specifications for the Flowmeter,Flowswitch, LoFlow and test equipment products areprovided in the respective pages for these products.

Ordering Information

Note: To add an electrically operated reed switch to your flowmeterplease order B26307

Product number

Brass flowmeter for air

FM26123332FM26223132FM26223232FM26323132FM26323232FM26423132FM26423232

Supersedes

FM.26 123 332FM.26 223 132FM.26 223 232FM.26 323 132FM.26 323 232FM.26 423 132FM.26 423 232

PortsBSP

1/4

1/2

1/2

3/4

3/4

11/4

11/4

SCFM

2 - 205 - 50

10 - 11015 - 12520 - 22540 - 40060 - 600

l/sec

1 - 102 - 255 - 506 - 60

10 - 10020 - 20030 - 300

Maximum workingpressure (bar)

41414141412525

Standard products tableFlow range

Product number

Stainless steel flowmeter for air

FM26133332FM26233132FM26233232FM26333132FM26333232FM26433132FM26433232

Supersedes

FM.26 133 332FM.26 233 132FM.26 233 232FM.26 333 132FM.26 333 232FM.26 433 132FM.26 433 232

PortsBSP

1/4

1/2

1/2

3/4

3/4

11/4

11/4

SCFM

2 - 205 - 50

10 - 11015 - 12520 - 22540 - 40060 - 600

l/sec

1 - 102 - 255 - 506 - 60

10 - 10020 - 20030 - 300

Maximum workingpressure (bar)

41414141414141

Standard products tableFlow range

Product number

FS643FS67AFS67B

2 switchesIntrinsically safe high switchIntrinsically safe low switch

Flow range SCFM and (l/sec)

2231223232313232

5 - 50 (2 - 25)10 - 110 (5 - 50)15 - 125 (6 - 60)

20 - 225 (10 - 100)

Ports (BSP)1/2

1/2

3/4

3/4

Fluid type

32 Air

Product configuratorBrass flowswitch for air Product number

FS643323232

Supersedes

FS.643 323 232

Ordering example

Productnumber

LF801450LF802455LF802452LF802454LF801451LF802453

Supersedes

LF.3007ELF.3050ELF.3135ELF.3720ELF.3021ELF.3330E

Ports (BSPTmale)1/4 - 3/4

3/4 - 3/4

3/4 - 3/4

3/4 - 3/4

1/4 - 3/4

3/4 - 3/4

Flow range

1.1 - 8.0 l/min10 - 50 l/min20 - 135 l/min

2 - 12 l/sec4 - 22 l/min

1.0 - 5.5 l/sec

Floatmaterial

AcetalAcetalAcetalS/SteelS/SteelS/Steel

Standard products table - LoFlow

Note 1: Part numbers featured with bold highlighted codes will ensure a ‘standard’ product selection.Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for availability.


Recommended