4
Inc. Components for Environmental Systems Marketing Consultants to the HVAC Industry www.marketair.com 1 Install Mounting Couplers & Fittings. Secure with screws provided. Clip Duct into place over installed lineset. 1 2 3 Provides easy mounting and elevates lineset from wall, ceiling or deck surface. Innovative New Design UV & weather resistant heavy duty PVC construction resists deformation. Light & Tough All duct and fittings disassemble for ease of installation, and mount with standard wall mounted pipe brackets. Easy Installation FUNCTIONAL DESIGN • PROFESSIONAL LOOK Protects any surface mounted lineset installation, as well as linesets between condenser and RD Series ducting system. Round profile in 3 sizes provides maximum strength and accomodates larger linesets and complicated configurations. enhances the appearance of any VRF application.
Transcript
Page 1: FUNCTIONAL DESIGN•PROFESSIONAL LOOK · for pd duct Ø0.2” 1.6” 0.3” c b a wall flange for pd fittings eccentric reducer pdj pdj • standard coupler pdc • end fitting end

Inc. Components for Environmental Systems • Marketing Consultants to the HVAC Industry • www.marketair.com 1

Install Mounting Couplers & Fittings.

Secure with screws provided.

Clip Duct into place over installed lineset.

1 2 3Provides easy mounting and elevates lineset from wall, ceiling or deck surface.

Innovative New Design

UV & weather resistant heavy duty PVC construction resists deformation.

Light & Tough

All duct and fittings disassemble for ease of installation, and mount with standard wall mounted pipe brackets.

Easy Installation

FUNCTIONAL DESIGN•PROFESSIONAL LOOKProtects any surface mounted lineset installation, as well as linesets between

condenser and RD Series ducting system. Round profile in 3 sizes provides maximum strength and accomodates larger linesets and complicated configurations.

enhances the appearance of any VRF application.

Page 2: FUNCTIONAL DESIGN•PROFESSIONAL LOOK · for pd duct Ø0.2” 1.6” 0.3” c b a wall flange for pd fittings eccentric reducer pdj pdj • standard coupler pdc • end fitting end

Inc. Components for Environmental Systems • Marketing Consultants to the HVAC Industry • www.marketair.com 2

BEFORE INSTALLATION, REFER TO THE PD SERIES INSTALLATIONMANUAL AVAILABLE ON OUR WEBSITE AT WWW.MARKETAIR.COM.

S=Stock Item NS=Non-Stock Item 6 WEEKS DELIVERY

All fittings are Stock

ITEM NO. A B (O.D.) C (I.D.) D S/NSPD-90-1000 ø3.5” ø3.6” 3” 37.8” S PD-90-1500 ø3.5” ø3.6” 3” 57.5” SPD-90-2000 ø3.5” ø3.6” 3” 78.7” NSPD-120-1000 ø4.6” ø4.7” 4.1” 37.8” SPD-120-1500 ø4.6” ø4.7” 4.1” 57.5” SPD-120-2000 ø4.6” ø4.7” 4.1” 78.7” NSPD-140-2000 ø5.5” ø5.6” 4.9” 78.7” S

ITEM NO. A B C D EPDB-90N-I ø3.8” 4.4” 5” 6.7” 2.7” PDB-120N-I ø4.9” 5.5” 6.1” 6.7” 2.7”PDB-140N-I ø5.8” 6.5” 7.2” 5.4” 2.4”

ITEM NO. A B C DPDE-90 4.1” 3.9” 5.6” 1.3” PDE-120 5.2” 5” 6.8” 1.3”PDE-140 6.5” 5.9” 8” 1.6”

ITEM NO. A B C D E FPDT-90-I 4.1” 3.9” 5.6” 4.1” 7.1” 1.3“PDT-120-I INCLUDES 2 5.2” 5” 6.8” 4.1” 8.4” 1.3”PDT-140-I ECCENTRIC REDUCERS 6.1” 5.9” 8” 5.2” 9.9” 1.6”

ITEM NO. A B C D EPDF-90 4.1” 3.9” 3.2” 1.5” 1.3” PDF-120 5.2” 5” 3.7” 1.5” 1.3”PDF-140 6.1” 5.9” 4.4” 1.8” 1.6”

DC

A B

BE

F

F

D C

PDT-90

B2.4”1.3”

F

FE

CD

A

APDT-120PDT-140

PD • DUCTDUCT

PD

PDB-N • MOUNTING COUPLER

MOUNTING COUPLER

PDB-N

PDE • 90° ELL

PDT • TEE

90° ELL

PDE PDF

TEE

PDT

PDF • 45° ELL45° ELL

BA C

DE

D

C

B

A

CE

D

B

A

PDT-120PDT-140with 2 reducersPDT-90

Page 3: FUNCTIONAL DESIGN•PROFESSIONAL LOOK · for pd duct Ø0.2” 1.6” 0.3” c b a wall flange for pd fittings eccentric reducer pdj pdj • standard coupler pdc • end fitting end

Inc. Components for Environmental Systems • Marketing Consultants to the HVAC Industry • www.marketair.com 3

BEFORE INSTALLATION, REFER TO THE PD SERIES INSTALLATIONMANUAL AVAILABLE ON OUR WEBSITE AT WWW.MARKETAIR.COM. All fittings are Stock

ITEM NO. A B C D EPDC-90 4.1” 3.9” 2.4” 1.8” 3.1” PDC-120 5.2” 5” 3.4” 2.2” 3.1”PDC-140 6.1” 6.3” 3.7” 2.4” 3.8”

ITEM NO. A B C D PDJ-90 4.1” 3.9” 3.1” 1.3” PDJ-120 5.2” 5” 3.1” 1.3”PDJ-140 6.1” 5.9” 3.8” 1.6”

ITEM NO. A B C PWP-90 4” 5.1” 6.2”PWP-120 5.1” 6.2” 7.3”PWP-140 5.9” 7.2” 8.2”

ITEM NO.PDJTN

ITEM NO. A B C PSP-90-I 3.5” 5.3” 6.2”PSP-120-I 4.6” 6.4” 7.3”

ITEM NO. A B C PDI-120-90-I 4.1” 5.2” 5”PDI-140-120-I 5.2” 6.1” 5.9”

ADAPTER FOR PD-90 5.1”

WITHOUT SOCKET

8”

8.4”

7.9” 15.9”

10.3

12”

WITH SOCKET

10.3

28.9”

12”

8”8.

4”

7.9”

AB

C

NO SOCKET VERSION

B

A

C

DD

STANDARD COUPLER E

BD

A

C

SOCKET

ADAPTERFOR PD-90

CBA

2-Ø0.2”

0.4”0.2”

WALL FLANGEfor PD Duct Ø0.2”

1.6”0.3”

CBA

WALL FLANGEfor PD Fittings

ECCENTRICREDUCER

PDJ

PDC • END FITTINGPDJ • STANDARD COUPLEREND FITTING

PDC

PDJTN • T-BRANCH

PWP • WALL FLANGE FOR PD DUCT PWP • WALL FLANGE FOR PD FITTINGS PDI • ECCENTRIC REDUCER

PWP PSP PDI

T-BRANCH

PDJTN

•Works with PD-140, PD-120 & PD-90 sizes.

Page 4: FUNCTIONAL DESIGN•PROFESSIONAL LOOK · for pd duct Ø0.2” 1.6” 0.3” c b a wall flange for pd fittings eccentric reducer pdj pdj • standard coupler pdc • end fitting end

Inc. Components for Environmental Systems • Marketing Consultants to the HVAC Industry • www.marketair.com 4

BEFORE INSTALLATION, REFER TO THE PD SERIES INSTALLATION MANUAL AVAILABLE ON OUR WEBSITE AT WWW.MARKETAIR.COM. All fittings are Stock

ITEM NO. A L PDY-90-I 9.2” 12.3” PDY-120-I 12.6” 15.7” PDY-140-I 15.4” 18.5”

ITEM NO. A B C A 11 214-60H 2.4” 2.3” 1”A 11 214-80H 3.1” 2.3” 1”A 11 214-100H 3.9” 2.3” 1.3”A 11 214-125H 4.9” 2.3” 1.3”

ITEM NO. DUCT SIZE A C D P t A 10363-80A PD-90 3.5” 1” 1.8” 0.8” 0.1”A 10363-100A PD-120 4.5” 1” 1.8” 0.8” 0.1”A 10363-125A PD-140 5.5” 1.3” 2.4” 1.1” 0.1”

ITEM NO.PDL

MOUNTING BAND

1.3”

ø0.4”

1.8”

1”

A

B C

A

t

DP

C

PDY

PDL • FITTING MOUNT CLIPPDY • MOUNTING BAND

TEE BRACKET

DETAILS OF SUPPORT SYSTEMS

TEE BRACKET

USING PDB MOUNTING COUPLER

HORIZONTAL HANGING

VERTICAL HORIZONTALUSING PDL CLIP ATTACHED TO FITTING

PIPE CLAMP

PIPE CLAMP

FITTING MOUNT CLIP

PDL

HORIZONTAL

VERTICAL SUPPORTHORIZONTAL DECK SUPPORT

LA

2.6”

1.2”

P.O. Box 10330, New Brunswick, NJ 08906 USAph: 732-985-8226 • fax: 732-985-2134 • [email protected]

Inc.

MOUNTING COUPLER

PDL FITTING MOUNT CLIP

TEE BRACKET

VERTICAL

DUCT

MIN 4”

MAX 16”


Recommended