G.E. UPS Productline
Transcript
Page 1: G.E. UPS  Productline

G.E.UPS Productline

Page 2: G.E. UPS  Productline

Uninterruptible Power Supplies | 1 PhaseDelivering reliable power in a compact footprint

LP11 / LP31T / LP31 Series

Application Medium data networks, telecom equipment, local site protection

Double conversion, high efficiency (up to 97%) and redundant parallel capable, with galvanic isolation and GE’s battery management for load security.

Line Interactive topology, automatic voltage regulation, step-wave output with internal hot swappable batteries.

IT & Match Series

Application Point-of-sale (POS), ISDN switches PCs, routers, & small IT servers

Application Healthcare & marine, wind turbine, controls, all IT & high speed processing

VH Series

GT SeriesDouble conversion, parallel-ready technology with modular battery and power components for easy expansion and retrofit.Application Telecom equipment, server racks, small to medium data networks

Double conversion technology, hardened design, peak load handling, and wide temperature operating range.

Rating Output Cert.600 VA – 2 kVA

120 Vac UL

500 VA – 3 kVA

230 Vac CE

Rating Output Cert.1 – 2kVA 120 Vac UL3kVA 120/208 Vac UL5 - 10kVA 120/208/240 Vac UL6 & 10kVA 220/230/240 Vac CE

Rating Output Cert.5-10 kVA 120/208/240 Vac UL &

CE3-10 kVA 220/230/240 Vac CE5-20 kVA 220/230/240 Vac CE

Rating Output Cert.2 kVA 208/220/230/240

VacUL

700 VA-3 kVA 208/220/230/240 Vac

CE

Page 3: G.E. UPS  Productline

Uninterruptible Power Supplies | 3 PhaseClean, reliable and energy efficient power

The high efficiency SG series provides fast step/transient load response while eliminating single points of failure.

SG Series

ApplicationEnterprise class data networks,large data centers, healthcare equipment

The LP33 series is a transformer-less design reducing install footprint and installation time.

LP33 Series

Application Large data networks, telecom equipment

The SitePro model is a robust, double conversion UPS that provides true on-line operation and galvanic isolation.

SitePro

ApplicationManufacturing & process controlhealthcare equipment, data centers

Leading the industry through innovationRedundant Parallel Architecture (RPA)Increasing reliability by eliminating single points of failure. Paralleling multiple UPS’ for true redundancy without adding complexity.ECO ModePower supplied from mains via UPS bypass circuit. Immediate transfer to inverter power during disturbance. Energy efficiency of up to 98.5%.PurePulse ®Delivers pure clean waveform from the mains, reducing sizing of upfront equipment and eliminating additional input filters.

Rating Output Cert.

10 - 750 kVA

480 Vac UL

60 - 500 kVA

400 Vac CE

Rating Output Cert.

10 - 100 kVA

208 Vac UL

10 - 120 kVA

380/400/415 Vac

CE

Rating Output Cert.

10 - 40 kVA

380/400/415 Vac

CE

Page 4: G.E. UPS  Productline

TLE Series Platform225 – 1500 kW

GECritical Power

Page 5: G.E. UPS  Productline

Page 5 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

TLE Series platform

Introducing TLE Series UPSWhat is it?TLE Series is a new high power transformer less 3 phase UPS platform with best in class multi-mode efficiency (eBoost and double conversion), and modular scalable from 200 kW up to 1500 kW for global UPS markets (CE and UL).

Why is it important?This TLE platform establishes GE technology leadership in mid/high power UPS applications with industry leading differentiation in efficiency, output power capacity and footprint.

Differentiated Value Proposition • Best in class multi-mode efficiency

• 96.5% Double Conversion mode (VFI)• 99.0% eBoost mode (VFD)

• Highest output power (up to 1.5 MW) • High reliability:

• Improved serviceability and lower MTTR• Standard building blocks 250 kw• Inherent redundancy inside UPS module

• High power density and small foot print• Excellent input , output performance

Page 6: G.E. UPS  Productline

Page 6 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

Ultra High Efficiency

Excellent Performance

Improved Diagnostic

High Reliability

High output power

Improved Serviceability

Creating Value – Low TCO

Page 7: G.E. UPS  Productline

Page 7 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

Creating Value – Low TCO

Ultra high Efficiency1

Page 8: G.E. UPS  Productline

Page 8 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

Double conversion Efficiency – 96.5%

High Efficiency at all loads Reduced customer operation costs and cost saving in air conditioning design

High efficiency performances High efficiency at full and partial

loads for real benefit in operating conditions

Energy cost savingReduced cost of customer equipment

operation at all loads

Air conditioning cost savingReducing size and cost of air

condition systemReducing consumption and related

operating cost

GE Sets the Bar for highest UPS Operating Efficiency

Page 9: G.E. UPS  Productline

Page 9 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

High Efficiency – eBoost mode

eBoosthigh efficiency (up to 99%)fast transfer to inverter

<2ms

"GE's eBoost feature expands a classic mode On-Line Double Conversion UPS System to a multi-mode UPS capable of maximizing operating efficiency commensurate with the stability of utility voltage and frequency

eBoost can be operated in RPA mode, up to 6 UPS modules in parallel, with all units operating and switching as one through redundant communication bus

Page 10: G.E. UPS  Productline

Page 10 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

High Efficiency – Low TCOHigh efficiency up to 96.5%Considerable life cycle cost savingsReduction in UPS operating costReduction in cooling cost

5 MW IT load - TLE series life cycle savings of $1.5 MM while operating in VFI mode

Assumptions: Power cost = $ 0.10 /kw-hr Operating hours/year = 8760Cooling factor = 0.35Configuration = S+S operating at

50% load

93%

96.5%

99%

Page 11: G.E. UPS  Productline

Page 11 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

High Efficiency – Low TCO

High efficiency up to 96.5%Considerable life cycle cost savingsReduction in UPS operating costReduction in cooling cost

Assumptions: Power cost = $ 0.10 /kw-hr Operating hours/year = 8760 Cooling factor = 0.35Configuration = 500 kW UPS @ 50%

load

TLE Series UPS annual savingsCompared to 92% efficiency UPS > $ 14,980 94% efficiency UPS > $ 8,140 95% efficiency UPS > $ 4,830

Page 12: G.E. UPS  Productline

Page 12 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

Creating Value – Low TCO

Excellent Performance2

Page 13: G.E. UPS  Productline

Page 13 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

UPS input performances Total Current Harmonic Distortion –

THDi <5% UPS input power factor: 0.99

Constant behavior at all loads Negligible harmonics contents at full

and partial loads

Programmable Soft Start Feature

Benefit on input mains Saving in the sizing of upfront

equipmente.g. GenSet, cablings, circuit breakers,

… No disturbances to nearby equipment Saving cost due to additional filters

Best in class input performance

Page 14: G.E. UPS  Productline

Page 14 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

High input performance means saving: GenSet size ( From 2 X Load kVA to 1.3 X Load kVA)

- Stable & longer life due to absence of harmonics

Circuit breaker size

Cabling section/size

Investment & space

Improved life for nearby equipments

No reactive power – saves on power compensation

Input performances benefit

Page 15: G.E. UPS  Productline

Page 15 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

Power capability – Unity power factor (kVA = kW)

Designed to supply real power for Unity power factor data centers load

Suitable for modern power supply application with unit or capacitive power factor (e.g. new servers generation), crest factor up to 3:1

UPS output power capability

11% more kW power compared to UPS with PF=0.9

No output voltage distortion with linear and non-linear loads

Voltage distortion- linear loads: THDv < 2-3%

- non-linear loads: THDv < 5%

Page 16: G.E. UPS  Productline

Page 16 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

UPS Input-Output PerformanceModule size optimization/ Electrical infrastructure utilization

4000 A Input Bus

6 x TLE 500 kW4 x TLE 750 kW

3 x TLE 1000 kW

2 x 1500 KW

3 MW Power

3000 A Input Bus

4 x TLE 500 kW3 x TLE 750 kW

2 X 1000 kW

2.25 / 2 MW Power

2000 A Input Bus

3 x TLE 500 kW2 x TLE 750 kW

1 x 1500 kW

1.5MW Power

11% more kW power compared to UPS with PF=0.9

Competitors units with 0.9 power factor provides less output power from same input bus size

Page 17: G.E. UPS  Productline

Page 17 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

Creating Value – Low TCO

Improved Diagnostic High Reliability3

Page 18: G.E. UPS  Productline

Page 18 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

New FLEX DSP board: the black-box• Waveform capture, diagnostic and trend analysis• Simultaneous acquisition of 32 channels• Sampling frequency up to 10kHz• Smart trigger capability with up to 16 indipendent trigger

sources to record only specific events with pre/post trigger data acquisition

• Buffer depth of 1000 samples per channel: each event is recorded for 100ms @ s.f. 10kHz

• 8 buffers to record up to 8 events without losing older events – can be extended with external USB mass storage devices

WAVEFORMS• Inverter voltages • Bypass voltages • Input mains voltages • Output voltages: • Output current Phases:• Input capacitors “Cin” voltages:• Inverter primary current: • Input current: • IDC current: • Battery current: • Bypass current:• UDC• Communication status RPA• Auxiliary status• SSM status• Fuses status• Phase error slave master.

Page 19: G.E. UPS  Productline

Page 19 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

Creating Value – Low TCO

Ease of InstallationImproved Serviceability4

Page 20: G.E. UPS  Productline

Page 20 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

Reduced footprint Compact design saving space in

installation- 225-250 kW: (w x d x h)

44.4 x 33.9 x 75.1 inch-400-500 kW:

66.9 x 33.9 x 75.1 inch

Standard Top-bottom cable entry Easier to handle High power density Savings in installation space

Compact design

1907 / 75.1”

1100 / 43.3”

TLE Series 250 kW

Page 21: G.E. UPS  Productline

Page 21 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

Improved serviceability

Improving Mean Time to Repair & Installation

Front access construction/design Draw out construction for fans & power

modules Common 250 kW power block & common

components Faster power block MTTR Easy access to customer connections Easy access to connectivity

Improved diagnostic capability

iUPS Guard – Remote monitoring

Standard back feed protectionInternal Option - Q2 (TLE 250-500) External Option – Q2 (TLE 750 -1500)

Page 22: G.E. UPS  Productline

Page 22 GE– Internal & Confidential

TLE Series 160-400 kVA/kW CE

Installation flexibility – RPA Cable Saver

1A2A3A

1B

2B

3B

Bypass input to UPS

Output from UPS

Competitors – 1A=2A=3A and 1B=2B=3B or max 10% difference

TLE Series with inductor = allows variation up to 20-25% (depends on UPS rating & cable section

Page 23: G.E. UPS  Productline

Page 23 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

Menu driven touch screen 7” display Critical measurement of input, output and battery included with mimic

diagram Quick operational status Different access level for user and service Different mimic diagram based on configuration Multilanguage communication interface

Advanced User Interface

Metering

Alarm

Set up

Command

RPA System

Page 24: G.E. UPS  Productline

Page 24 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

Advanced User Interface

Menu driven touch screen display

Page 25: G.E. UPS  Productline

Page 25 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

Advanced User Interface

Menu driven touch screen display Separate screen for RPA system with status and measurements Metering screen by tabs Home button inside each screen Improved alarm and events screen Easy to use set up screen

Page 26: G.E. UPS  Productline

Page 26 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

Creating Value – Low TCO

Summary5

Page 27: G.E. UPS  Productline

Page 27 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

Differentiated TLE Series UPS

Efficiency

Black BoxLimited life component monitoring

High Reliability

Small foot printProduct options

Font accessNew control

panelDraw out

construction

96.5%THDi 3-5%, Input pf 0.99Output pf -1

Page 28: G.E. UPS  Productline

Page 28 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

TLE Series UPS

Differentiating:• Best in class double conversion efficiency - up to 96.5%• Ultra high efficiency in eBoost mode of operation - up to

99%• Static bypass inductor • Compact foot print provides very high power density• Excellent input, output performance• Improved diagnostic capability with black box• Ease of installation and Improved serviceability

Page 29: G.E. UPS  Productline

Page 29 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

3-Level topology

High Efficiency at all loads Reduced customer operation costs and cost saving in air conditioning design

High efficiency performances The TLE Series UPS uses a three level technology with an Advanced Neutral Point Clamped topology implemented with true Reverse Blocking IGBT. These result in reduced switching and filter losses with respect to a standard two level technology

Page 30: G.E. UPS  Productline

Page 30 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

Improved diagnostic, High Reliability

Improving Mean Time to Repair Wave form capture capability Fan failure detection

Improving Reliability & Diagnostic AC Capacitor health monitoring Component life time counters Dedicated supply path for bypass logic Redundant Isolated power supply Robust RPA communication No total OFF button to avoid human error Heat sink & input, output filter coils temperature

monitoring

Page 31: G.E. UPS  Productline

Page 31 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

• Double conversion (VFI) technology• Automatic bypass for overloads, short circuit and UPS disturbances

conditions • Manual bypass Q2 (optional) for UPS maintenance operations without

load interruption (225-500 kW internal option) • Standard common mains• Number of battery blocks – 40-42

- back feed protection K6 standard

UPS configurationOptional – TLE Series 225-500 kW

TLE Series 225-500 kW

Page 32: G.E. UPS  Productline

Page 32 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

Supplemental Cabinetry• VRLA Battery Cabinet Systems• Flywheel DC Energy Storage• 480/480V External Maintenance Bypass• 480/208V External Maintenance Bypass (250kw max)

Optional Equipment• 480/415VAC Input Isolation Xfmr• 600VAC Input Isolation Xfmr• Remote Alarm Status Panel• Dual Input• RPA Card for parallel operation• eBoost Software for multi-mode operation

Installation flexibility - Product options

ISM (intelligent Synchronization module) – not supported

Page 33: G.E. UPS  Productline

Page 33 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

Remote monitoring – TLE Series

iUPSGuard – Remote monitoring

Improved response time 24 x7 monitoring & alarm

notification of UPS Improved pre dispatch diagnostic

& first time fix Regular status reports Highly secure communication

Page 34: G.E. UPS  Productline

Page 34 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

Customer ConnectivityEasy integration with Building Management System (BMS)

Customer interfaceUPS supervision capability1x RS232 Serial Communication Port6 programmable potential free alarm

contacts: - D plug - Terminals blocks

1x Emergency Power OFF contact1x Gen-ON Input contact1x Control Input contact

Additional interface:SNMP Interface Card

(10/100Mbps auto-select)MODBUS Interface (RS232 or RS485)iUPSGuard (free license during

warranty)- SNMP card required for iUPSGuard

Page 35: G.E. UPS  Productline

Page 35 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL

Configurable up to 6 units in parallel

Future expansion Safe and reliable power supplyRedundant Communication Bus

Redundant Parallel Architecture

Easy to install and maintainEasy system upgrade/downgradeMaintenance operation without

load interruptionRPA cable saver allows

installation flexibility

System reliability improved by RPA

Page 36: G.E. UPS  Productline

Page 36 GE– Internal & Confidential

TLE Series 250-500 kVA/kW UL


Recommended